Sie sind auf Seite 1von 2

0 0.

01
0.49
0.02
0.48 0 0.49
0.01
d 180 0.0
Tow
l oa 7 0.02 170 0.48
3
ard
rd 0.4 -170 ge n
wa 3 0.4 er
To 0.0 0 160 7 a to
6 -16 0.0
4 r
0.4
4 0.4
6
0.0
0 15
0 0.

0.1
0.1
45 -15 05
.0
0.
05 45
0.

0.2
0.2
0.
44 40
14 06
0. 0.1 0
-1 0.
06 44

0.3
0.

0.3
0.

43
07

.0
0
0.

30
13
43

0.

0.
4
0. 0

-1 7
4
0.2

2
0.0
8

0.4
0.4
0.
5
2

0
0.

0 .08
5
0.3 12
0

-12

1
0.0

9
9

0.4
0.4
1

0.0
0.6
0.4
0.6

0
110

-11
0.5
0.10

0.40
0.7
0.40

0.10
0.7

0.6
0.8
0.11

0.39
0.39

0.11
0.8
0.7
100

-100
0.9 0.8
0.9
0.9
0.12

0.38
0.38

0.12
1.0 1.0
90

-90
1.1 1.0
0.37

0.13
0.13

0.37
1.2
1.3
1.4
80

1.5

-80
Smith Chart

0.36

0.14
0.14

0.36
2
0.35

0.15
0.15

0.35
70

-70 6
0.3

4
4

0.1
0.1

3
6

0.3
60

-607
2.0
0.3

4
3

0.1

3
2.0
0.1
7

0.3
5

0
0.
50

-5
18
6
32

0.
0.

32
18

0.
7
3.

3.
0

0
0.
0.
19
0
10 40
31
0.
31 -4 19
0.
4.
4.0

0
0.
20 20 30
5.0

0.
5.0

0.
30 30 20
0. -30
10

10

1 0.2
9
0.2
9 0.2
1
0.2 -20 0.2 20
2 8
0.2
8 -10 10 0.27 0.2
2
0.2 0.23 0
0.24 0.26
0.25 0.23
0.27
0.26 0.24
0.25

www.teicontrols.com/notes/GraphPaper
Using the Smith Chart

First normalize the load impedance by dividing by the characteristic impedance, and find this point on
the chart.
When working in terms of reactance, an inductive load will be located on the top half of the chart, a
capacitive load on the bottom half. It's the other way around when working in terms of susceptance.
Draw a straight line from the center of the chart through the normalized load impedance point to the edge
of the chart.
Anchor a compass at the center of the chart and draw a circle passing through the normalized load
impedance point. Points along this circle represent the normalized impedance at various points along the
transmission line. Clockwise movement along the circle represents movement from the load toward the
source, with one full revolution representing 1/2 wavelength as marked on the outer edge of the Smith
chart. The two points where the circle intersects the horizontal axis are the voltage maxima (right) and
the voltage minima (left).
The point opposite the impedance (180° around the arc) is the admittance. The reason admittance (or
susceptance) is useful is because admittances in parallel are simply added. (Admittance is the reciprocal
of impedance; susceptance is the reciprocal of reactance.)

Reflection coefficient: Smith Chart


Z − Z0 r + j ⋅ x − 1 Imag.
ρ= =
Z + Z0 r + j ⋅ x + 1 v
!"#"$ x=
normalized form

1.0
1 − (u 2 + v 2 ) 2⋅v
r% + %
j⋅x = + ⋅

2.0
0.

j
5

(!"#"$
1 − u ) + v2 (1 − u ) + v2
2 2
real imag.
!""#"" $
real imaginary
5.0
r=
Reflection coefficient in the complex plane:
ρ = u + j ⋅v u
1.0
0.5
0.1

Inductive
2

5
Re
Capacitive
Normalized load impedance:
1+ ρ 5.
RL ( norm ) = = r + j⋅x 0

1+ ρ
Input impedance:
2.0
5

Z + jZ 0 tan (β l )
0.

1+ ρ
Z in = Z 0 = Z0 L
1.0

1− ρ Z 0 + jZ L tan (β l )
where βλ = 2π

The u and v axes are normally not shown on the Smith Chart. With respect to these axes, ρ is zero when
at the origin and one when on the outer circle. The distance from ρ to the origin in the magnitude of ρ. If
ρ is greater than one, that means there is gain.
Using the Smith chart, we assume α=0, otherwise the circular path taken around the chart would be a
spiral. α is the real part of the complex propagation constant γ where γ = ZY = α + jβ and βλ = 2π .

www.teicontrols.com/notes/GraphPaper