T/O Wall
Roof/Floor Line
2.75 ft
6 ft
6 ft
45o
16 in
5.17 ft
5.5 ft
1.400
0.0
ft 5.503
A 1 B
0.514
0.0
ft 5.503
A 1 B
Project Job Ref.
5.302
5.3
ft 5.503
A 1 B
0.0
-3.853
-3.9
ft 5.503
A 1 B
Support conditions
Support A Vertically restrained
Rotationally free
Support B Vertically restrained
Rotationally free
Applied loading
Beam loads Self - Dead self weight of beam 1
Wall - Dead full UDL 257 lb/ft
Live roof - Live full UDL 600 lb/ft
Load combinations
Load combination 1 Support A Dead 1.20
Live 1.60
Span 1 Dead 1.20
Live 1.60
Support B Dead 1.20
Live 1.60
Load combination 2 Support A Dead 1.40
Span 1 Dead 1.40
Support B Dead 1.40
Analysis results
Maximum moment; Mmax = 5.302 kip_ft; Mmin = 0 kip_ft
Maximum shear; Vmax = 3.85 kips; Vmin = -3.85 kips
Maximum reaction at support A; RA_max = 3.9 kips; RA_min = 1.4 kips
Unfactored dead load reaction at support A; RA_Dead = 1 kips
Unfactored live load reaction at support A; RA_Live = 1.7 kips
Maximum reaction at support B; RB_max = 3.9 kips; RB_min = 1.4 kips
Project Job Ref.
Reinforcement details
Yield strength; fy = 60000 psi
Modulus of elasticity of steel; Es = 29000000 psi
Reinforcement yield strain; y = fy / Es = 0.002
Cover to reinforcement
Bottom cover to reinforcement; cnom_b = 1.5 in
Side cover to reinforcement; cnom_s = 1.5 in
d = 13.19 in
16 in
2 x No.5 bars
7.625 in
;
WARNING Lintel qualifies as deep beam (ACI 318,10.7.1). Assumption of linear strain distribution may not apply
Section properties
Modular ratio; n = Es / Em = 21.48
Section width; b = 7.625 in
Section depth; h = 16 in
Net cross-sectional area; An = b h = 122 in2
Net shear area; Anv = b h = 122 in2
Section modulus; S = b h2 / 6 = 325.33 in3
Depth to tension reinforcement; d = 13.19 in
Moment of inertia of net section; In = b h3 / 12 = 2602.7 in4
Cracked moment of inertia; Icr = min(0.5 Ig, b (k d)3 / 3 + n As (d - k d)2) = 1207.4 in4