Beruflich Dokumente
Kultur Dokumente
NACIONAL DE LOJA
MEMORIA TCNICA
INTEGRANTES:
Mara Camila Arrobo Fernndez
Nelson Eduardo Barrazueta Valle
Carlos Eduardo Flores Gaona
DOCENTE:
Ing. Andy Vega
MDULO:
Sptimo B
TABLA DE CONTENIDO
1.ANTECEDENTES ..................................................................................................................................... 4
1.1. UBICACIN .................................................................................................................................... 4
1.2. ESTRUCTURA ................................................................................................................................. 4
1.2.1. PLANTA BAJA .......................................................................................................................... 4
1.2.2. PRIMERA PLANTA ................................................................................................................... 4
1.2.3. SEGUNDA PLANTA .................................................................................................................. 4
1.2.4. TERCERA PLANTA ................................................................................................................... 4
2. ALCANCE DEL PROYECTO ..................................................................................................................... 5
3. CARACTERIZACIN FSICA DEL INMUEBLE ........................................................................................... 5
4. SISTEMA DE VOZ Y DATOS.................................................................................................................... 6
4.1. INTRODUCCIN A LAS NORMAS DE LOS SISTEMAS DE CABLEADO ESTRUCTURADO................... 6
4.1.1. TIA/EIA-568-B ......................................................................................................................... 7
4.1.2. TIA/EIA-569 ............................................................................................................................ 8
4.1.3. TIA/EIA-606-A ......................................................................................................................... 9
4.1.4. TIA/EIA-TSB-67 ....................................................................................................................... 9
4.2. JUSTIFICACIN DE LA SOLUCIN ADOPTADA ............................................................................. 10
4.3. ESPECIFICACIONES TCNICAS ...................................................................................................... 15
4.4. DISTRIBUCIN ............................................................................................................................. 18
4.4.1. TOMAS DE DATOS ................................................................................................................ 18
4.4.2. TOMAS DE VOZ..................................................................................................................... 24
4.4.3. TOTAL DE TOMAS DE VOZ Y DATOS ..................................................................................... 30
5. SISTEMA DE ALARMA CONTRA INCENDIOS ....................................................................................... 30
5.1. INTRODUCCIN ........................................................................................................................... 30
5.2. DESARROLLO ............................................................................................................................... 30
5.3. ESPECIFICACIONES TCNICAS ...................................................................................................... 31
5.4. DISTRIBUCCIN ........................................................................................................................... 33
5.4.1. SENSORES DE HUMO Y TEMPERATURA ............................................................................... 33
5.4.2. ESTACIONES MAUALES ......................................................................................................... 36
5.4.3. LUCES ESTROBOSCPICAS ................................................................................................... 38
5.4.4. TOTAL DE EQUIPOS USADOS ................................................................................................ 39
6. SISTEMA DE ALARMA CONTRA ROBO ................................................................................................ 39
2
6.1. INTRODUCCIN ........................................................................................................................... 39
6.2. DESARROLLO ............................................................................................................................... 40
6.3. ESPECIFICACIONES TCNICAS ...................................................................................................... 42
6.4. DISTRIBUCIN ............................................................................................................................. 45
7. SISTEMA DE CCTV ............................................................................................................................... 47
7.1. INTRODUCCIN ........................................................................................................................... 47
7.2. DESARROLLO ............................................................................................................................... 48
7.3. ESPECIFICACIONES TCNICAS ...................................................................................................... 50
7.4. DISTRIBUCIN ............................................................................................................................. 52
3
1. ANTECEDENTES
1.1. UBICACIN
El presente proyecto detalla el diseo de cableado estructurado para el edificio del IESS ubicado en la
ciudad de Sangolqu (Venezuela y Montfar), cantn Rumiahui, provincia de Pichincha.
1.2. ESTRUCTURA
La edificacin consta de cuatro pisos distribuidos de la siguiente manera:
Este diseo se lleva a cabo teniendo en cuenta las necesidades de los usuarios en este tipo de centros,
dotndolo de las tecnologas ms adecuadas teniendo en cuenta siempre en dejar la infraestructura en
previsin necesaria para que dicho centro pueda actualizarse conforme a las necesidades presentes y
futuras.
4
2. ALCANCE DEL PROYECTO
El alcance de este documento comprende:
Cables de datos
Elementos de interconexin
Equipos electrnicos a implementar.
El proyecto contempla la electrnica de red que permita implementar la topologa prevista en esta red
de rea local, de manera acorde con los estndares y normativas que son de aplicacin.
5
Oficina 1 130,08 m
Oficina 2 29,92 m
Oficina 3 20,98 m
SEGUNDA
Oficina 4 27,12 m
PLANTA
Oficina 5 97,15 m
Sala de Reuniones 12,88 m
Secretaria 32,21 m
Oficina 1 130,08 m
Oficina 2 29,92 m
Oficina 3 20,98 m
TERCERA
Oficina 4 27,12 m
PLANTA
Oficina 5 97,15 m
Sala de Reuniones 12,88 m
Secretaria 32,21 m
Tabla 1: reas de lo espacios del edificio.
Un sistema de cableado estructurado es fsicamente una red de cable nica y completa, con
combinaciones de alambre de cobre (UTP), cables de fibra ptica, bloques de conexin, cables
terminados en diferentes tipos de conectores y adaptadores.
Disponer de tomas de acceso terminal estandarizadas tanto para voz como para datos o bien
para cualquier otra necesidad telemtica.
Distribuye dichas tomas en los diferentes departamentos de acuerdo a las necesidades y
mantiene cierto nmero de lugares de posible uso futuro.
La distribucin de esta red se lleva a cabo ya sea en una planta, en un edificio o bien en un
campus o conjunto de edificios.
La gestin de administracin de la red se realiza desde unos puntos en los cuales se instalan
distribuidores, repartidores o concentradores en los cuales confluyen las diferentes lneas de
cable o fibra ptica.
Con todo lo expuesto, se pretende que el sistema a ejecutar aporte simplificacin en la gestin de
redes, flexibilidad y facilidad para poder llevar a cabo cambios de configuracin y tecnologa. De igual
manera permite la integracin en esta red de mltiples servicios de telemtica bajo el mismo soporte
simplificando los procedimientos y obteniendo altos niveles de calidad y eficacia. Otro punto
6
importante es destacar la vida til del sistema de cableado estructurado ya que es muy superior a otros
sistemas que se emplean para la prestacin de servicios.
Por lo tanto y teniendo en cuenta todas estas caractersticas es necesaria una cuidadosa planificacin
y ejecucin para asegurar que la inversin realizada garantice que la misma es capaz de dar soporte a
las necesidades presentes y permita la flexibilidad suficiente para otras en el futuro. Finalmente una de
las herramientas fundamentales es que todo el proyecto se realice conforme a los estndares o normas
especficos para cableado estructurado.
Estas son las normativas a las que se rige el presente proyecto de diseo para lograr todas las
caractersticas descritas hasta ahora en este documento.
4.1.1. TIA/EIA-568-B
La norma TIA/EIA 568B dicta las regulaciones para Cableado Estndar de Telecomunicaciones para
edificios comerciales
7
Interfaces de usuario
Prcticas de instalacin
Rendimiento de la lnea.
Cableado Horizontal
Cableado Vertical (Backbone del Edificio y del Campus)
rea de Trabajo (WA)
Closet de telecomunicaciones (TC)
Cuarto de Equipos
Entradas de Servicio (EF)
Para el diseo del proyecto partimos de la normativa de cableado horizontal que detalla la distancia
mxima que debe existir entre el WA hasta el cuarto de telecomunicaciones TC que es de 90m con un
adicional de 10m para la distancia combinada de cables de empate utilizados para conectar el WA y el
TC. De la misma forma la topologa de conexin se la realiza en estrella. El cable a emplear es UTP
Categora 6a. Los dems elementos para el sistema de cableado estructurado se detallan ms adelante.
4.1.2. TIA/EIA-569
La norma TIA/EIA-569 detalla las regulaciones para Espacios y Rutas de Telecomunicaciones estndar
para Edificios Comerciales. Da el conocimiento de las rutas y espacios que deben soportar para una
gran variedad de servicios de telecomunicaciones adems de voz y datos. Son especificaciones para
soportar multi-productos y multi-fabricantes.
8
Cuarto de Equipos
Entrada de servicios.
En el presente diseo de acuerdo a la norma la ruta escogida para el paso de la escalerilla principal se
la realiza por cielo falso respetando las distancias mnimas respecto del tendido elctrico, as como las
medidas de la escalerilla para el soporte y ubicacin del cable. As mismo para el diseo de las rutas
verticales, el cuarto y closet de telecomunicaciones ubicados estratgicamente para dar cumplimiento
a la norma.
4.1.3. TIA/EIA-606-A
Es le estndar de Administracin para la infraestructura de Telecomunicaciones en Edificios
comerciales. El sistema de administracin puede ser de forma manual (papel), hojas de clculo o
software dedicado para esta funcin.
En esta norma se determinan cuatro clases a ser administradas, el diseo de la edificacin en estudio
se encuentra determinado en la clase dos, sin embargo, debido a que la administracin es opcional se
decide no llevar a cabo todas aplicaciones de registros que implican esta norma, no obstante cada
elemento del sistema de cableado se encuentra debidamente identificado y etiquetado para un
perfecto cumplimiento de la regulacin si se evala bajo los criterios descritos anteriormente.
4.1.4. TIA/EIA-TSB-67
Es el estndar de Especificaciones de las pruebas de campo de los Sistemas de Cableado Estructurado.
Define las especificaciones para las pruebas que se deben realizar despus de la instalacin. Verifica el
funcionamiento del enlace.
9
Con esta norma se puede determinar la calidad del enlace. Como es una norma que se aplica una vez
instalados los elementos del sistema de cableado solo hasta entonces se podr verificar la misma. Los
parmetros de atenuacin, diafona, longitud y mapeo determinarn la eficiencia del sistema instalado.
Los tendidos realizados con cable UTP Categora 6a de 4 pares sern los necesarios para satisfacer los
requisitos y la electrnica deber cumplir en todo momento la posibilidad de disponer en la base
terminal de cada punto una conexin de 1 Gb.
El inmueble no requiere la implementacin de un Centro de Proceso de Datos, lo que significa que esta
funcin puede ser desempeada perfectamente por el Cuarto de Telecomunicaciones localizado en la
primera planta.
La localizacin de este punto y desde el cual se distribuye en topologa estrella hacia todas las bases de
acceso terminal de los diferentes servicios, permite tener distancias controladas cuyas longitudes, para
el caso del cableado horizontal nunca sobrepasan los 90 metros que impone la norma.
La solucin del sistema de distribucin en topologa estrella para la red telemtica ser la adoptada
con las restantes instalaciones, ya sea televisin, seguridad e incendios.
El rea de puesto de trabajo deber incluir todos los elementos necesarios para la conexin de un
equipo terminal a la red de cableado estructurado. La conexin de las mismas se realizar en las tomas
de telecomunicacin dispuestas en las diferentes reas de trabajo mediante latiguillos de conexin tipo
UTP categora 6a.
El nmero de tomas de voz y datos de cada zona de trabajo depende de la naturaleza uso o clasificacin
del mismo. En los anexos 1 se detalla el listado de los mismos. Las tomas terminan en conectores tipo
hembra Rj45 categora 6a tipo UTP insertado en un face place panduit de 1 o 2 posiciones dependiendo
del caso. Las tomas de telecomunicacin irn alojadas en cajas rectangulares profundas empotradas
en paredes o suelo segn sea el caso. De ser necesario y no teniendo otra solucin se puede poner
tomas sobrepuestas.
Se emplean cajas de paso para tomar las bajantes desde la escalerilla principal hacia la toma de
telecomunicaciones, se conectan a la red general mediante tubo conduit de salvo en casos
puntuales donde se utiliza tubera conduit 1.
10
La conexin entre el equipo del usuario y la roseta se lo realiza mediante patch cords panduit categora
6a 3FT (0.91m) en el cuarto de telecomunicaciones con patch cords panduit categora 6a 7FT (2.13m)
cumpliendo con la distancia mxima establecida en la norma.
En el caso que nos ocupa al cableado horizontal tiene su origen en el panel de parcheo del armario de
distribucin principal localizado en la primera planta, se realiza la interconexin con el distribuidor
secundario para finalizar en la roseta que forma el puesto de trabajo. La escalerilla de distribucin
principal est localizada en el teco falso del edificio en cada una de las plantas. Se ha respetado la
distancia frente a otros servicios principalmente los de baja tensin, lo que garantiza inmunidad frente
a cualquier tipo de interferencia inducida. El dimensionamiento de la escalerilla garantiza siempre
radios de curvatura superiores a 5cm en los puntos de cruce de la red.
11
de administrable nos permite determinar la jerarqua de los elementos a conectar, as como la
velocidad de conexin y la proteccin de la red contra intrusos.
Los switches de distribucin de planta se recomiendan marca HPE 1950 48G, con tecnologa PoE Capa
2. Tiene 48 puertos 48x10/100 + 2xGigabit SFP combinado. Las prestaciones de servicio para la red son
de alta calidad y el costo es promedio.
Se designan switches secundarios administrables para poder realizar el cableado vertical. La capacidad
administrable nos permite adems de dar seguridad a la red jerarquizar un switch de planta para poder
realizar las interconexiones entre plantas.
Los Racks que se utilizan para la instalacin de los dispositivos electrnicos son de marca BEAUCOUP
gabinete abatible Neptuno, cdigo I-60529 de 25u que soportan carga mxima de 300 kg. La disposicin
de los dispositivos en el rack ser de la siguiente manera:
1U 23 OR-01PB
1U 22 PP-01PB Datos
1U 21 Reserva
1U 20 SWA-02PB Voz
1U 19 OR-02PB
1U 18 PP-02PB Datos
1U 17 Reserva
1U 16 Reserva
1U 15 Reserva
1U 14 Reserva
1U 13 Reserva
1U 12 Reserva
1U 11 Reserva
1U 10 Reserva
1U 9 Reserva
1U 8 Reserva
1U 7 Reserva
1U 6 Reserva
1U 5 Reserva
1U 4 Reserva
1U 3 Reserva
12
1U 2 Reserva
1U 1 Multitomas
Tabla 2
13
1U 21 Reserva
1U 20 SWA-02SP Voz
1U 19 OR-02SP
1U 18 PP-02SP Datos
1U 17 Reserva
1U 16 Reserva
1U 15 Reserva
1U 14 Reserva
1U 13 Reserva
1U 12 Reserva
1U 11 Reserva
1U 10 Reserva
1U 9 Reserva
1U 8 Reserva
1U 7 Reserva
1U 6 Reserva
1U 5 Reserva
1U 4 Reserva
1U 3 Reserva
1U 2 Reserva
1U 1 Multitomas
TABLA 4
14
1U 10 Reserva
1U 9 Reserva
1U 8 Reserva
1U 7 Reserva
1U 6 Reserva
1U 5 Reserva
1U 4 Reserva
1U 3 Reserva
1U 2 Reserva
1U 1 Multitomas
TABLA 5
Se utilizan UPS de 30 minutos de reserva para la alimentacin de cada armario en cada planta.
Conmutador Gigabit
Switch
PoE + 8 G +180W, HP 1920-8G-PoE
Administrable HP
2SFP GbE. 8 Puertos CAPA 2
Pricipal
RJ45
Conmutador Switch.
PoE+ con 52 puertos
en total: 48 puertos
Switch HPE 1950 48G
PoE+2 SFP Gigabit HP
Secundario 2SFP+2XGT
10/100/100+2
Puertos Rj45
1/10GBASE-T
Gigabit/Ethernet.
Patch Panel Cumple Normas CPP48WBLY PANDUIT
EIA/TIA 568B
Organizador de cables
Organizador
Horizontal 1U, para WMPH1E PANDUIT
de Cables
gabinetes y racks 19"
15
Cable de Parcheo UTP
10Gb 7FT con
Patch Cord
conectores modulares
rea de 20460P7A PANDUIT
TX6A en ambos
Trabajo
extremos Categoria
6a
Mdulo universal
Jack RJ45- Categoria 6A, RJ45,
10185PAN6A PANDUIT
Cat6A 10Gb/s 8 posiciones,
8 cables 568A/568B
Gabinete Rack
Gabinete Abatible Neptuno.
I-1026-N BEAUCOUP
Rack Norma INEN 2568 ICE
60529, 19" 25U
16
Multitoma para Rack
de 19" para
Multitomas I-1135 TPL 19-4 BEAUCOUP
alimentacin elctrica
de
Fabricadas bajo
normativa IEC 60529.
Galvanizada en frio
Cajas de Paso laminado con tapa I-206 BEAUCOUP
metlica
desmontable. Servicio
Pesado
17
Escalerilla para
tendido de redes de
telefona y datos.
Bandeja Tipo I-0772-BNJE
Fabricado en acero BEAUCOUP
Escalerilla 150/100
pregalvanizado.
Desarmable. Soporta
hasta 112Kg/m
Conector Plug 8, 8
wire TX6A modular.
Contactos chapados
Plug RJ45- Plug Conector
con 50 micro PANDUIT
Cat6A RJ45 Cat 6A
pulgadas de oro.
Terminal 24 AWG.
Bolsa 100 unidades
4.4. DISTRIBUCIN
4.4.1. TOMAS DE DATOS
PLANTA BAJA TOMAS DE DATOS
1 TD-PB01 SWA-01PB
2 TD-PB02 SWA-01PB
SALA 3D
3 TD-PB03 SWA-01PB
4 TD-PB04 SWA-01PB
6 TD-PB06 SWA-01PB
7 TD-PB07 SWA-01PB
SALA 2D
8 TD-PB08 SWA-01PB
9 TD-PB09 SWA-01PB
10 TD-PB10 SWA-01PB
SALA DE CRISIS
11 TD-PB11 SWA-01PB
18
12 TD-PB12 SWA-01PB
13 TD-PB13 SWA-01PB
COMEDOR DE
14 AP-PB01 SWA-01PB
PERSONAL
16 TDD-PB01 SWA-01PB
COPIADO
17 TDD-PB02 SWA-01PB
18 TDD-PB03 SWA-01PB
19 TDD-PB04 SWA-01PB
21 TDD-PB06 SWA-01PB
22 AP-PB03 SWA-01PB
TABLA 7
1 TD-PP01 SWA-01PP
2 TD-PP02 SWA-01PP
3 TD-PP03 SWA-01PP
5 TD-PP05 SWA-01PP
6 TD-PP06 SWA-01PP
7 TD-PP07 SWA-01PP
8 TD-PP08 SWA-01PP
19
11 TD-PP11 SWA-01PP
12 TD-PP12 SWA-01PP
13 TD-PP13 SWA-01PP
14 TD-PP14 SWA-01PP
15 TD-PP15 SWA-01PP
16 TD-PP16 SWA-01PP
17 TD-PP17 SWA-01PP
18 TD-PP18 SWA-01PP
19 TD-PP19 SWA-01PP
20 TD-PP20 SWA-01PP
21 TD-PP21 SWA-01PP
22 TD-PP22 SWA-01PP
OFICINA 1
23 TD-PP23 SWA-01PP
24 TD-PP24 SWA-01PP
25 TD-PP25 SWA-01PP
26 TD-PP26 SWA-01PP
27 TD-PP27 SWA-01PP
28 TD-PP28 SWA-01PP
29 AP-PP03 SWA-01PP
32 AP-PP02 SWA-01PP
SECRETARIA
33 TD-PP30 SWA-01PP
34 TD-PP31 SWA-01PP
OFICINA 3
35 TD-PP32 SWA-01PP
20
36 TD-PP33 SWA-01PP
37 TD-PP34 SWA-01PP
TABLA 8
1 TD-SP01 SWA-01SP
2 TD-SP02 SWA-01SP
3 TD-SP03 SWA-01SP
5 TD-SP05 SWA-01SP
6 TD-SP06 SWA-01SP
7 TD-SP07 SWA-01SP
8 TD-SP08 SWA-01SP
10 TD-SP10 SWA-01SP
11 TD-SP11 SWA-01SP
12 TD-SP12 SWA-01SP
13 TD-SP13 SWA-01SP
OFICINA 5
14 TD-SP14 SWA-01SP
15 TD-SP15 SWA-01SP
16 TD-SP16 SWA-01SP
17 TD-SP17 SWA-01SP
18 TD-SP18 SWA-01SP
20 TD-SP20 SWA-01SP
21
21 TD-SP21 SWA-01SP
22 TD-SP22 SWA-01SP
23 TD-SP23 SWA-01SP
24 TD-SP24 SWA-01SP
25 TD-SP25 SWA-01SP
26 TD-SP26 SWA-01SP
27 TD-SP27 SWA-01SP
28 TD-SP28 SWA-01SP
29 AP-SP03 SWA-01SP
32 AP-SP02 SWA-01SP
SECRETARIA
33 TD-SP30 SWA-01SP
34 TD-SP31 SWA-01SP
35 TD-SP32 SWA-01SP
OFICINA 3
36 TD-SP33 SWA-01SP
37 TD-SP34 SWA-01SP
38 TD-SP35 SWA-01SP
OFICINA 1
39 TD-SP36 SWA-01SP
TABLA 9
1 TD-TP01 SWA-01TP
OFICINA 4
2 TD-TP02 SWA-01TP
3 TD-TP03 SWA-01TP
22
4 TD-TP04 SWA-01TP
5 TD-TP05 SWA-01TP
6 TD-TP06 SWA-01TP
7 TD-TP07 SWA-01TP
8 TD-TP08 SWA-01TP
10 TD-TP10 SWA-01TP
11 TD-TP11 SWA-01TP
12 TD-TP12 SWA-01TP
13 TD-TP13 SWA-01TP
OFICINA 5
14 TD-TP14 SWA-01TP
15 TD-TP15 SWA-01TP
16 TD-TP16 SWA-01TP
17 TD-TP17 SWA-01TP
18 TD-TP18 SWA-01TP
19 TD-TP19 SWA-01TP
20 TD-TP20 SWA-01TP
21 TD-TP21 SWA-01TP
22 TD-TP22 SWA-01TP
24 TD-TP24 SWA-01TP
25 TD-TP25 SWA-01TP
26 TD-TP26 SWA-01TP
27 TD-TP27 SWA-01TP
28 TD-TP28 SWA-01TP
23
29 AP-TP03 SWA-01TP
32 AP-TP02 SWA-01TP
SECRETARIA
33 TD-TP30 SWA-01TP
34 TD-TP31 SWA-01TP
35 TD-TP32 SWA-01TP
OFICINA 3
36 TD-TP33 SWA-01TP
37 TD-TP34 SWA-01TP
38 TD-TP35 SWA-01TP
OFICINA 1
39 TD-TP36 SWA-01TP
TABLA 10
1 TV-PB01 SWA-02PB
2 TV-PB02 SWA-02PB
SALA 3D
3 TV-PB03 SWA-02PB
4 TV-PB04 SWA-02PB
6 TV-PB06 SWA-02PB
7 TV-PB07 SWA-02PB
SALA 2D
8 TV-PB08 SWA-02PB
9 TV-PB09 SWA-02PB
24
11 TV-PB11 SWA-02PB
12 TV-PB12 SWA-02PB
13 TV-PB13 SWA-02PB
15 TVD-PB01 SWA-02PB
17 TVD-PB03 SWA-02PB
18 TVD-PB04 SWA-02PB
TABLA 11
1 TV-PP01 SWA-02PP
2 TV-PP02 SWA-02PP
3 TV-PP03 SWA-02PP
5 TV-PP05 SWA-02PP
6 TV-PP06 SWA-02PP
7 TV-PP07 SWA-02PP
8 TV-PP08 SWA-02PP
10 TV-PP10 SWA-02PP
11 TV-PP11 SWA-02PP
13 TV-PP13 SWA-02PP
14 TV-PP14 SWA-02PP
25
15 TV-PP15 SWA-02PP
16 TV-PP16 SWA-02PP
17 TV-PP17 SWA-02PP
18 TV-PP18 SWA-02PP
19 TV-PP19 SWA-02PP
20 TV-PP20 SWA-02PP
21 TV-PP21 SWA-02PP
23 TV-PP23 SWA-02PP
24 TV-PP24 SWA-02PP
25 TV-PP25 SWA-02PP
26 TV-PP26 SWA-02PP
27 TV-PP27 SWA-02PP
28 TV-PP28 SWA-02PP
31 TV-PP31 SWA-02PP
32 TV-PP32 SWA-02PP
OFICINA 3
33 TV-PP33 SWA-02PP
34 TV-PP34 SWA-02PP
TABLA 12
2 TV-SP02 SWA-02SP
26
3 TV-SP03 SWA-02SP
4 TV-SP04 SWA-02SP
5 TV-SP05 SWA-02SP
6 TV-SP06 SWA-02SP
7 TV-SP07 SWA-02SP
8 TV-SP08 SWA-02SP
10 TV-SP10 SWA-02SP
11 TV-SP11 SWA-02SP
12 TV-SP12 SWA-02SP
13 TV-SP13 SWA-02SP
OFICINA 5
14 TV-SP14 SWA-02SP
15 TV-SP15 SWA-02SP
16 TV-SP16 SWA-02SP
17 TV-SP17 SWA-02SP
18 TV-SP18 SWA-02SP
19 TV-SP19 SWA-02SP
20 TV-SP20 SWA-02SP
21 TV-SP21 SWA-02SP
22 TV-SP22 SWA-02SP
23 TV-SP23 SWA-02SP
24 TV-SP24 SWA-02SP
25 TV-SP25 SWA-02SP
26 TV-SP26 SWA-02SP
27
28 TV-SP28 SWA-02SP
31 TV-SP31 SWA-02SP
32 TV-SP32 SWA-02SP
OFICINA 3
33 TV-SP33 SWA-02SP
34 TV-SP34 SWA-02SP
35 TV-SP35 SWA-02SP
OFICINA 1
36 TV-SP36 SWA-02SP
TABLA 13
1 TV-TP01 SWA-02TP
2 TV-TP02 SWA-02TP
3 TV-TP03 SWA-02TP
5 TV-TP05 SWA-02TP
6 TV-TP06 SWA-02TP
7 TV-TP07 SWA-02TP
8 TV-TP08 SWA-02TP
10 TV-TP10 SWA-02TP
11 TV-TP11 SWA-02TP
OFICINA 5
12 TV-TP12 SWA-02TP
13 TV-TP13 SWA-02TP
28
TV-TP14
14 SWA-02TP
15 TV-TP15 SWA-02TP
16 TV-TP16 SWA-02TP
17 TV-TP17 SWA-02TP
18 TV-TP18 SWA-02TP
19 TV-TP19 SWA-02TP
20 TV-TP20 SWA-02TP
21 TV-TP21 SWA-02TP
22 TV-TP22 SWA-02TP
24 TV-TP24 SWA-02TP
25 TV-TP25 SWA-02TP
26 TV-TP26 SWA-02TP
27 TV-TP27 SWA-02TP
28 TV-TP28 SWA-02TP
31 TV-TP31 SWA-02TP
32 TV-TP32 SWA-02TP
OFICINA 3
33 TV-TP33 SWA-02TP
34 TV-TP34 SWA-02TP
35 TV-TP35 SWA-02TP
OFICINA 1
36 TV-TP36 SWA-02TP
TABLA 14
29
4.4.3. TOTAL DE TOMAS DE VOZ Y DATOS
PRIMERA PLANTA 37 34
SEGUNDA PLANTA 39 36
TERCERA PLANTA 39 36
5.1. INTRODUCCIN
Todas las edificaciones en algn momento se ven expuestas a algn siniestro. Los accidentes suelen
ocurrir, pero hay que estar preparados para cuando eso ocurra. Por ello, todos los edificios deben de
contar con un sistema de alarma contra incendio que garantice la seguridad de proveedores,
empleados, y recursos tecnolgicos. Esto es una forma de brindar tranquilidad y estar preparados ante
cualquier inconveniente.
Los sistemas de alarma contra incendio, son fundamentales para la proteccin de plantas, edificios,
laboratorios, etc. Estos sistemas deben garantizar una respuesta rpida y efectiva ante cualquier
emergencia que se pudiera suscitar.
Se ha realizado el diseo de un sistema de alarma contra incendios para el edificio del IESS ubicado en
la ciudad de Sangolqu (Venezuela y Montfar), cantn Rumiahui, provincia de Pichincha. El mismo
que cuenta con los componentes esenciales para el correcto funcionamiento del sistema y que se
especificarn ms adelante.
5.2. DESARROLLO
Los dispositivos del sistema de alarma contra incendios ofrecen una gran seguridad y confiabilidad
gracias a las diferentes tecnologas que se encuentran en el mercado y que tenemos a la disposicin.
Para nuestro diseo utilizaremos los siguientes componentes:
30
Es un dispositivo electrnico que es el cerebro de nuestro sistema de alarma contra incendios
su funcin principal es el mantenimiento y comprobacin de diferentes dispositivos que
forman parte de un sistema de deteccin de incendios tales como: sensores de humo y
temperatura, estaciones manuales, luces estroboscpicas, entre otros.
LUCES ESTROBOSCPICAS
Son dispositivos de iluminacin porttiles que emiten las luces que destellan de intensidad alta.
ESTACIONES MANUALES
Es un aparato que est diseado para ser activado en caso de incendio, tirando de una
manivela. Al ser activado el aparato informa de inmediato a la central de deteccin de
incendios.
CENTRAL DE INCENDIO
- Cuatro zonas de
iniciacin (expandibles a
ocho); hasta 20
detectores de humo de
dos cables por zona. FPD-7024 BOSCH
- Se convierte fcilmente
en direccionable con la
incorporacin de un
mdulo de expansin
mltiple D7039.
- Teclado alfanumrico
TECLADO LCD de doble lnea 32
caracteres.
- Leds identificadores de
alarma, problema,
supervisin y
silenciado. FMR-7033 BOSCH
- Direccionamiento por
Jumper.
- Mximo 4 por central
FPD-7024
- Distancia mxima
305m con cable
18AWG.
31
DETECTOR FOTOELCTRICO
DE HUMO Y TEMPERATURA
- Voltaje de entrada DC
DE 2 HILOS 12/32V
- Corriente de alarma 40-
80mA (DC12/32 V)
- Temperatura de
DHFK2 STARLIGH
operacin 10C-50C.
- rea de deteccin de
60m2 a 4m de altura.
- Proteccin de metal
para interferencias
electromagnticas
32
6) (admite direcciones 9
a 128).
- Ampla la cantidad de
cdigos de usuario a
100 PIN.
- Aumenta la memoria
intermedia histrica a
499 eventos.
- Compatible con RPS
5.4. DISTRIBUCCIN
5.4.1. SENSORES DE HUMO Y TEMPERATURA
1 SHT-01PB SEGURIDAD
2 SHT-02PB ESPERA
3 SHT-03PB COPIADO
4 SHT-04PB SALA 3D
5 SHT-05PB CUARTO
6 SHT-06PB
SALA 2D
7 SHT-07PB
33
8 SHT-08PB SALA DE CRISIS
9 SHT-09PB PASILLO
COMEDOR DE
10 SHT-10PB
PERSONAL
11 SHT-11PB COCINA
12 SHT-12PB BODEGA
13 SHT-13PB CORREDOR
14 SHT-14PB
AUDITORIO
15 SHT-15PB
CUARTO DE
17 SHT-17PB
TELECOMUNICACIONES
TABLA 17
1 SHT-01PP
OFICINA 5
2 SHT-02PP
4 SHT-04PP
OFICINA 4
5 SHT-05PP
DUCTOS DE
6 SHT-06PP
INSTALACIONES
7 SHT-07PP
8 SHT-09PP PASILLO
9 SHT-12PP
9 SHT-10PP SECRETARIA
34
10 SHT-11PP OFICINA 2
12 SHT-08PP
13 SHT-13PP OFICINA 1
14 SHT-14PP
CUARTO DE
15 SHT-15PP
TELECOMUNICACIONES
TABLA 18
1 SHT-01SP
OFICINA 5
2 SHT-02SP
4 SHT-04SP
OFICINA 4
5 SHT-05SP
DUCTOS DE
6 SHT-06SP
INSTALACIONES
7 SHT-07SP
8 SHT-09SP PASILLO
9 SHT-12SP
10 SHT-10SP SECRETARIA
11 SHT-11SP OFICINA 2
12 SHT-08SP
13 SHT-13SP OFICINA 1
14 SHT-14SP
CUARTO DE
15 SHT-15SP
TELECOMUNICACIONES
35
TABLA 19
1 SHT-01TP
OFICINA 5
2 SHT-02TP
4 SHT-04TP
OFICINA 4
5 SHT-05TP
DUCTOS DE
6 SHT-06TP
INSTALACIONES
7 SHT-07TP
8 SHT-09TP PASILLO 1
9 SHT-12TP
10 SHT-10TP SECRETARIA
11 SHT-11TP OFICINA 2
12 SHT-08TP
13 SHT-13TP OFICINA 1
14 SHT-14TP
CUARTO DE
15 SHT-15TP
TELECOMUNICACIONES
TABLA 20
1 EM-01PB PASILLO
36
2 EM-02PB ESPERA
3 EM-03PB ESPERA
TABLA 21
1 EM-01PP
PASILLO
2 EM-02PP
CERCA DEL
3 EM-03PP
ASCENSOR
TABLA 21
1 EM-01SP
PASILLO
2 EM-02SP
CERCA DEL
3 EM-03SP
ASCENSOR
TABLA 22
1 EM-01TP
PASILLO
2 EM-02TP
CERCA DEL
3 EM-03TP
ASCENSOR
TABLA 23
37
5.4.3. LUCES ESTROBOSCPICAS
1 LE-01PB PASILLO
2 LE-02PB ESPERA
3 LE-03PB ESPERA
TABLA 24
1 LE-01PP
PASILLO
2 LE-02PP
3 LE-03PP ESCALERAS
CERCA DEL
4 LE-04PP
ASCENSOR
TABLA 25
1 LE-01SP
PASILLO
2 LE-02SP
3 LE-03SP ESCALERAS
CERCA DEL
4 LE-04SP
ASCENSOR
TABLA 26
38
1 LE-01TP
PASILLO
2 LE-02TP
3 LE-03TP ESCALERAS
CERCA DEL
4 LE-04TP
ASCENSOR
TABLA 27
PRIMERA PLANTA 15 3 4
SEGUNDA PLANTA 15 3 4
TERCERA PLANTA 15 3 4
TOTAL 62 12 15
TABLA 28
6.1. INTRODUCCIN
Los sistemas de alarma contra robo son populares y utilizados por muchas personas y
establecimientos. Hoy en da es comn hablar de instalar una alarma en una casa y bastante
ms usual en un comercio u oficina.
El objetivo de este sistema de alarma contra robo es prevenir el delito de robo contra la
propiedad, disuadir al potencial intruso y dar aviso a las autoridades correspondientes. Ningn
sistema de alarma tiene la capacidad de evitar el robo, pero esta es una consecuencia directa
de su uso. Es decir, que un sistema de alarma slo podr evitar un delito si cumple con las
caractersticas de disuasin y aviso.
39
Para que pueda cumplir con este objetivo, se hace imprescindible un diseo del sistema que
incluye un relevamiento de la propiedad en cuestin, la utilizacin adecuada de los mejores
dispositivos del mercado y una correcta instalacin. A esto hay que agregarle un uso y un
mantenimiento correctos.
Como todo sistema que interacta con personas, se debe adecuar a las costumbres de stas y
se dise de tal manera que no dependa de la voluntad de stas, sino que acte por s solo
cumpliendo su funcin. El sistema debe entonces ser capaz de verificar el estado de las reas
protegidas y a s mismo, avisando de algn modo al usuario o al departamento tcnico de
anomalas o situaciones anormales.
El usuario a su vez deber entender que dicho sistema necesita encenderse en el momento
que se quiera proteger la propiedad y deber estar alerta a los avisos que este haga,
entendiendo que ignorar un aviso del sistema puede resultar en la prdida o disminucin de
la seguridad.
6.2. DESARROLLO
El documento establece los requerimientos mnimos para la incorporacin de las ltimas tecnologas
en cuanto a sistemas de alarmas para inmuebles no-residenciales. Los parmetros establecidos en este
caso por esa asociacin no slo se refieren a la deteccin de incendios, sino tambin a controles de
acceso, circuitos cerrados de televisin, deteccin de intrusos, biometra, tipos de alarmas e incluso la
disposicin de los cableados correspondientes a cada sistema.
Normas como sta son de libre adhesin, pero en la medida en que sean acatadas por sectores
poderosos tales como las industrias aseguradora, bancaria o turstica, su conocimiento y aplicacin se
harn indispensables. Sus efectos no sern vistos de inmediato sino en el mediano plazo, cuando las
instituciones de los distintos niveles gubernamentales orienten sus compras y contratos de servicio
segn sus dictados. No obstante, mientras la industria estadounidense se reacomoda es importante
que los pases latinoamericanos estn alertas.
La norma NFPA 731, que suministra especificaciones para la instalacin de sistemas y dispositivos
electrnicos de seguridad en los tipos de instalaciones incluidas, est siendo desarrollada como una
norma y es similar a la norma NFPA 72, Cdigo nacional de alarma contra incendios.
40
El objetivo de la norma NFPA 731 tambin incluye los requisitos para el cableado, fuentes de energa,
supervisin, prueba y mantenimiento, control de acceso y vigilancia.
La norma NFPA 731 abarca el Control del acceso, el sistema de CCTV y la integracin de estos sistemas
como tambin la interface de los sistemas de seguridad de edificios con los sistemas de seguridad
humana.
La norma NFPA 731 no est diseada para requerir un nivel de seguridad de edificios; en realidad
establece los niveles mnimos requeridos de desempeo, el punto de superfluidad y calidad de las
instalaciones. No establece as los nicos mtodos por los que se deben alcanzarse los requisitos.
Los requisitos de la norma NFPA 731 estn diseados para aumentar la calidad y confiabilidad de las
instalaciones y reducir la desmesurada cantidad de falsas alarmas debido a una pobre instalacin,
aplicacin y capacitacin; estos son:
SEGURIDAD ELECTRNICA.
Los requisitos propuestos de la NFPA 731 incluyen: Los planes del sistema de seguridad de edificios
debern ser desarrollados por personas con experiencia en el diseo, aplicacin, instalacin y
evaluacin adecuados de los sistemas de seguridad de edificios. Se deber identificar al diseador del
sistema en los documentos de diseo del sistema. Se debern suministrar pruebas de su aptitud cuando
41
fuera as requerido por una autoridad competente. Ejemplos de personal calificado incluyen, pero no
se limitan a:
El comit tcnico de la norma NFPA 731 ha decidido que, en su primera edicin, la norma NFPA 731
slo abarcar los edificios protegidos desde la lnea de la propiedad hacia el interior del edificio y no
abarcar la operacin de la Estacin Central ya que se relaciona con el monitoreo de sealizacin de
seguridad.
SENSOR MAGNETICO
42
Lmites de temperatura de
operacin 32 F - 120 F
(0 C - 49 C)
Inmunidad a la radiofrecuencia y a
las ondas electromagnticas 50
V/m desde 0.01 hasta 1,200 MHz
Humedad relativa 5% - 95%
Inmunidad a la corriente esttica
25kV
Inmunidad a las corrientes
transitorias 2.4kV a 1.2 J
Velocidad de deteccin de
movimiento al caminar (0.15 - 3
m/s)
BATERA DSC
Duracin de 8 horas
Voltaje 12V
Capacidad 5.0
Peso 1.56Kg
Dimensiones 90*70*101*107
BOCINA DSC
43
2 Tonos.
115 dB.
20 Watts.
Color Blanco.
TRANSFORMADOR DSC
110v a 12v
Peso 6.5 libras (3 kg)
Dimensiones (27930084mm)
44
UTP Cat3-25PARES Conductores de cobre slido
Aislamiento de PVC
Conductores pareados y cableados
Cubierta exterior de PVC
Sin blindar
TABLA 29
6.4. DISTRIBUCIN
DISTRIBUCIN GLOBAL
Movimiento 9
PLANTA BAJA
Magnticos 8
Teclado 1
Bocina 1
Magnticos 2
Magnticos 2
Magnticos 2
TABLA 30
DISTIBUCION INDIVIDUAL
PLANTA BAJA
45
movimiento SM-05-PB ESPERA
PRIMERA PLANTA
SEGUNDA PLANTA
46
magntico SMG-02-P2 SEGURIDAD
TERCERA PLANTA
TABLA 31
7. SISTEMA DE CCTV
7.1. INTRODUCCIN
Un sistema de CCTV realiza la supervisin de aquellos puntos coherentes con la seguridad como son los
puntos vulnerables del recinto de las instalaciones. Las imgenes obtenidas de dichos puntos podrn
ser visualizadas de forma automtica, como resultado de una alarma.
Las funcionalidades bsicas del sistema de CCTV por tanto son las siguientes:
Seleccin de imgenes captadas por una cmara determinada para ser visualizadas en un
monitor.
Seleccin de imgenes captadas por varias cmaras para ser visualizadas
simultneamente.
Posibilidad de secuenciamiento de las imgenes captadas por un grupo de cmaras.
Grabacin de las imgenes captadas por una o varias cmaras.
Reproduccin de grabaciones de seguridad de cualquier cmara.
Gestin de alarmas y anomalas que se puedan producir en el sistema.
El despliegue de un sistema CCTV IP resulta ms sencillo y econmico que un sistema analgico, pues
si las cmaras disponen de alimentacin por PoE (Power Over Ethernet) estas se alimentan con el
mismo cable de datos o cable UTP con el que se transmite la imagen.
Por lo que, si la distancia hasta la cmara no sobrepasa los 100m (el mximo de distancia para el
correcto funcionamiento del cable UTP), slo se requiere el tendido de un nico cable.
Un sistema CCTV de tecnologa IP adopta los beneficios analgicos de los tradicionales CCTV con las
ventajas digitales de las redes de comunicacin IP, permitiendo la inspeccin local de las imgenes, as
como su tratamiento digital.
47
7.2. DESARROLLO
El documento establece los requerimientos mnimos para la incorporacin de las ltimas tecnologas
en cuanto a sistemas de alarmas para inmuebles no-residenciales. Los parmetros establecidos en este
caso por esa asociacin no slo se refieren a la deteccin de incendios, sino tambin a controles de
acceso, circuitos cerrados de televisin, deteccin de intrusos, biometra, tipos de alarmas e incluso la
disposicin de los cableados correspondientes a cada sistema.
Normas como sta son de libre adhesin, pero en la medida en que sean acatadas por sectores
poderosos tales como las industrias aseguradora, bancaria o turstica, su conocimiento y aplicacin se
harn indispensables. Sus efectos no sern vistos de inmediato sino en el mediano plazo, cuando las
instituciones de los distintos niveles gubernamentales orienten sus compras y contratos de servicio
segn sus dictados.
La norma NFPA 731, que suministra especificaciones para la instalacin de sistemas y dispositivos
electrnicos de seguridad en los tipos de instalaciones incluidas, est siendo desarrollada como una
norma y es similar a la norma NFPA 72, Cdigo nacional de alarma contra incendios.
El objetivo de la norma NFPA 731 tambin incluye los requisitos para el cableado, fuentes de energa,
supervisin, prueba y mantenimiento, control de acceso y vigilancia.
La norma NFPA 731 abarca el Control del acceso, el sistema de CCTV y la integracin de estos sistemas
como tambin la interface de los sistemas de seguridad de edificios con los sistemas de seguridad
humana.
La norma NFPA 731 no est diseada para requerir un nivel de seguridad de edificios; en realidad
establece los niveles mnimos requeridos de desempeo, el punto de superfluidad y calidad de las
instalaciones. No establece as los nicos mtodos por los que se deben alcanzarse los requisitos.
Los requisitos de la norma NFPA 731 estn diseados para aumentar la calidad y confiabilidad de las
instalaciones y reducir la desmesurada cantidad de falsas alarmas debido a una pobre instalacin,
aplicacin y capacitacin; estos son:
CAMARAS.
48
Todas las cmaras se instalarn segn las instrucciones del fabricante.
Las cmaras se instalarn por las siguientes condiciones ambientales que no afecten a sus
actividades: la formacin de hielo, los ngulos de la luz del sol, las temperaturas extremas, la
carga del viento, la lluvia.
El cable coaxial debe tener una impedancia de 75 ohms.
Cuando se utiliza UTP para transmisin de seal de vdeo, la distancia mxima no exceder las
instrucciones del fabricante.
La seguridad local electrnica elctrica y los cables del sistema deben ser del calibre apropiado,
hilos, aislamiento y las propiedades elctricas segn lo especificado por el fabricante del
equipo.
Un bucle de servicio mnimo de 15,24 cm deber ser de al panel de control y recintos utilizados
para las terminaciones de cableado.
Un bucle de servicio mnimo ser de 15,24 cm en las terminaciones de campo.
Los requisitos propuestos de la NFPA 731 incluyen: Los planes del sistema de seguridad de edificios
debern ser desarrollados por personas con experiencia en el diseo, aplicacin, instalacin y
evaluacin adecuados de los sistemas de seguridad de edificios. Se deber identificar al diseador del
sistema en los documentos de diseo del sistema.
Se debern suministrar pruebas de su aptitud cuando fuera as requerido por una autoridad
competente. Ejemplos de personal calificado incluyen, pero no se limitan a:
El comit tcnico de la norma NFPA 731 ha decidido que, en su primera edicin, la norma NFPA 731
slo abarcar los edificios protegidos desde la lnea de la propiedad hacia el interior del edificio y no
abarcar la operacin de la Estacin Central ya que se relaciona con el monitoreo de sealizacin de
seguridad.
49
7.3. ESPECIFICACIONES TCNICAS
EQUIPOS ESPECIFICACIONES
DVR PANASONIC
Disco duro de 1Tera
El doble de su capacidad de
grabacin con la funcin de
registro largo de Panasonic
Grabar hasta 684 Horas en HD
vs 259 horas en modo normal
CMARA HD PANASONIC
Rj-45
Se utiliza para interconectar las
computadoras en redes locales
(LAN) en interiores de oficinas,
escuelas, hogares, etc.
Conexin de 8 pines.
UTP Cat 5e
UTP con espectro de 100MHz
Distancia 100m
Aplicacin LAN 100Base-T
Blindado
Impedancia de 100omhs
50
4 pares
SWITCH PANDUIT
TABLA 32
51
7.4. DISTRIBUCIN
DISTRIBUCIN GLOBAL
Exterior 1
TABLA 33
DISTIBUCION INDIVIDUAL
PLANTA BAJA
PRIMERA PLANTA
SEGUNDA PLANTA
52
interior CV-SP-01 ESPERA
TERCERA PLANTA
TABLA 34
53