Sie sind auf Seite 1von 1

BFM-900

Technical Specifications
Ultrasound Trend
Multicrystal Transducer 72 hours
Pulsed Doppler
Ultrasound Frequency : 2.0 MHz Function
Intensity : <10mW/cm2 Multi Screen :3 type

BFM-900 FHR Range : 50 ~ 240 bpm


FHR Accuracy : 2% of range
Dual Doppler
MARK Function
Paper Feeding Function
Zoom in Particular Response (DOP2 +20bpm)
Waterproofing (IPX 7) Auto Print Function 10, 20, 30, 40, 50, 60 min

UC Signal Interface
External Type Ethernet Central Interface
Frequency Response : DC ~ 0.5 Hz
Versatile and portable intrapartum monitor Reference(Zero) Control
Measurement Range : 0 ~ 99 units
Environmental Specifications
Temperature Range
Waterproofing (IPX 7)
- Operating : 10 to 45
Top quality beyond absolute FECG (Optional Sensor)
- Storage : -10 to 50
Relative Humidity Range
Fetal Monitoring FHR Range : 50 ~ 240 bpm - Operating : 30 ~ 85%
Input Impedance : > 10 Mohm - Storage : 20 ~ 95%
Leakage Current :
< 0.04 uA/V at 50/60 Hz

FM (Fetal Movement) Power Specifications


Detection Method : Ultrasound Power Requirements :
Dual FM 100 - 240VAC, 50/60Hz, about 80VA
Output : DC +15V 3.0A
AST (Acoustic Simulator : Optional ) Battery : Rechargeable Li-ion battery: +11.1V, 4400mAh
Vibration Function Waking Fetus

BFM-900 is customized for the special Display


requirements of obstetrical care department. Screen : 7Wide TFT Color LCD
Resolution : 480 X 3(RGB) X 234
It is compact, but powerful, enough for inter- Heart Rhythm
departmental transfer and it is sophisticated, but Signal Quality
Printing State
easy-to-use, enough for reliable communication
Record Speed : 1,2,3 cm/min
with fetus. Auto Print 10, 20, 30, 40, 50, 60 cm/min
Indicator : Power & Battery LED
Alarm on/off State LED
BFM-900 captures fetal rate and uterine contractions
and displays results and traces on a clear 7"wide Sound
TFT LCD. It includes more 3 different configurations, Doppler Sound with Volume Control
Information Sound
uterine contraction period display, selectable Grid, Printer Paper Out
real-time volume control, a round & 360 degree Probe Fault
Low Battery
visible alarm lamp.
Alarm Sound
As well as user s configurable auto-time recording DOP I, DOP II, FECG High & Low Limit
and once printing at a high-speed is provided with
Printer
built-in thermal printer and rechargeable Li-ion
Thermal Array Type
battery. Record Speed : 1,2,3 cm/min
Record Contrast : mode 1, 2, 3 Accessory >>
Auto Record Period : Off, 10, 20, 30, 40, 50, 60 min
BFM-900 is the ultimate solution, providing
convenient fetal assessment, non-stress testing, Set-up
autocorrelation algorithm and AST(Acoustic Alarms Upper/Lower Value
Time & Date
Simulator). Print Contrast 1, 2, 3

All specifications are subject to change without notice