Beruflich Dokumente
Kultur Dokumente
MOSELECTRO
Engineering Center
projects
projects projects projects
Gas-insulated
Low-voltage busbars (up busducts:
to 1 kV):
High-voltage SF6-insulated
Busbar with molded polymer busbars.
insulation; and
Busbar with sandwich insulation.
Air-insulated busbar
Packaged supplies of
systems:
electrical equipment for energy
Complete enclosed busbars;
facilities complete with
Complete medium-voltage busbars; and
busbars for any system
Low-voltage busbars.
Distribution busbars are intended for electric power Trunk line busbars are used for electric
distribution between consumers, using special power transmission from the source to a
devices for power takeoff from the main busduct line distribution point (distribution stations,
(cable splice boxes, junction boxes with automatic distribution busducts) or to high electric
circuit breaker, etc.). loads.
4
Sphere of Application for RBCEffibar Low-voltage
Busbars
Applications of RBCEffibar busbars:
Lighting, conditioning, pumps,
In business centers and high-rise buildings: elevators
As a feeder between
transformers and main
switchboards;
For power distribution to the
floors via riser boards;
Horizontal installation as a
feeder to switchboards and
equipment; and
As indoor power distribution
ducts/ channels in suspended
ceilings and floors.
Electric power
distribution
Electric power
transmission
5
Sphere of Application for RBCEffibar
Low-voltage Busbars
At industrial facilities and indoors
Electric power
distribution
Electric power
distribution
6
Sphere of Application for RBCEffibar Low-voltage
Busbars
In hotels, sports venues and institutions:
As a feeder between transformers and main switchboards; and
For power distribution to the floors via riser boards.
Transportation Lighting
In trade centers/supermarkets:
As a feeder between
transformers and main
switchboards;
For electric power distribution in
vertical and horizontal routing;
and
As a feeder for power supply to
light fixtures.
In data centers.
Electric power
distribution
7
Dimensions and Weight of RBCEffibar Busbars
Copper conductors: Aluminum conductors:
3200 125 352 53.3 59.6 2500 125 392 26.0 28.1
4000 125 432 68.8 77.3 3200 125 492 32.8 35.7
5000 125 532 88.2 99.4 4000 125 572 39.2 42.9
6300 125 701 114.5 128.9 5000 125 700 54.2 56.4
8
Description of RBCEffibar Busbar:
Conductors Used
Conductor materials:
9
Description of RBCEffibar Busbar:
Insulation Features
Mylar insulation:
Insulation of each bus consists of three layers 0.2 mm thick each;
10
Description of RBCEffibar Busbar:
Body Features
Design:
The body consists of 2 parts instead of conventional 4 parts;
Enhanced moisture/dust protection; and
High mechanical strength.
Material: aluminum with magnesium alloy:
Effective heat removal;
Usage of the body as an earthing lead;
Low weight;
Corrosion resistance (1,000 hours in salt mist); and
No eddy currents.
11
Description of RBCEffibar Busbar:
Joint Blocks
Single-block joint;
12
Description of RBCEffibar Busbar:
Power Takeoff Boxes
L1=360 mm
L2=930 mm
L3=1,500 mm
L4=2,070 mm
L5=2,640 mm
Non-standard length:
LVC: L=720~2,990 mm
LVA: L=720~4,000 mm 14
Description of RBCEffibar Busbar:
Power Takeoff Section Design
Bonding pads:
Rated current up to 1,000 A; and
Silver plated.
Full compliance with the sandwich busbar design excludes potential flame,
smoke or gas propagation at power takeoff points.
This design also ensures the equality of fault currents both on a straight
transport section and a socket section.
15
Description of RBCEffibar Busbar:
Terminal Element
16
Description of RBCEffibar Busbar:
Special Elements
Thermal expansion section
17
Advantages of Busbars over Cables:
Simple design;
Quick and easy installation;
Compact size and low weight;
Expandability and possibility to add new loads;
Service life of busbars is at least 40 years as opposed to
15 years for cables;
Busbars do not require maintenance during the entire
service life;
Lower electric losses;
Busbars are fully fire-safe;
Mechanical strength margin; and
Low EMR level.
18
When a Busbar is the Most Cost-
efficient Solution:
A busbar costs less than many cable systems. Cost
reduction from busbar application is the most notable
in case of:
19
Advantages of RBCEffibar Busbars
over Counterparts
Hilton, UK
Experience in manufacture of this busbar design since the
80s;
Provision of the full range of services for design, installation/
installation supervision, start-up and commissioning,
guarantee and post-guarantee maintenance; Bank of Tanzania
20
Application of RBCEffibar Busbars at Various
Facilities
21
Application of RBCEffibar Busbars at Various
Facilities
22
www.rbc-energo.ru