Low Voltage Switchgear

Understanding the challenges.


Engineering the solutions.

Oil and Gas Data Center Healthcare Industrial


As a premier leader in power distribution equipment, Eaton
offers a wide range of innovative, low voltage switchgear
designs providing flexible solutions to optimize operational
performance, enhance safety and save space.

Rear access Front access


Lower installation and When floor space is limited, or room
maintenance costs, higher constraints dictate that equipment be
interrupting and withstand mounted against a wall, why compromise
ratings, enhanced safety, on switchgear design?
higher quality, reliability and
maintainability Eatons Magnum DS front-accessible
switchgear combines the robustness of
UL 1558 low voltage switchgear with the
flexibility of UL 891 switchboard design.
The front-accessible switchgear offering
allows mounting against a wall, or in other
tight locations, where a standard rear-
accessible switchgear lineup would not
normally fit.

UL1558/891 Levering Magnum DS


breaker through the door
Up to 10,000A continuous
current horizontal main bus
Up to 5,000A continuous
UL 1558
current vertical riser bus Up to 6,000A continuous
Short circuit withstand rating current horizontal main bus
of 200,000 amperes with no Up to 5,000A continuous
fuses. current vertical riser bus
Bus standard bracing is 100, 150 and 200 kA bus
100,000 amperes optional bracing designs
150,000
600 Vac class
4-wire applications, 100%
neutral
NEMA1 indoor

Ground the full length of the


NEMA 3R outdoor, both aisle
Integrated HRG
switchgear assembly and aisleless enclosures
Standard 40.20-inch
NRX integration
Optional safety shutters
switchgear depth 800A continuous current
Rear cover or doors with 65KA short circuit
Up to 4-high breaker
Control wire standard Type SIS and 42KA short time
arrangement
insulated stranded copper. (30 cycle withstand) for
Breaker sections are 18, 22 or UL 1558
Integrated HRG optional (HRG 44 inches wide
can be stand alone or wall
mount)
Cable compartments are 18, 1200A continuous current
22, 30 or 44 inches wide with 65KA short circuit
MDN 4000A in 30 structure for UL 891
508 Vac100 kAIC
maximum short circuit 24 enclosure two
3P NRX breakers side
635 Vac65 kAIC maximum
by side
short circuit

2 EATON Low Voltage Switchgear


Improved maintainability Increased reliability Reduced installation cost Increased safety
with dedicated secondary with modular design allows with front-accessible controls with complete enhanced
terminals with separate access for reduced parts for both and wiring enables rapid performance suite of options
door and front accessible structures and breakers installation and commissioning
control wireway

Shown with plenum.


Can be provided without plenum. Shown without plenum. Plenum and duct can be added upon request.

ArcGardarc-resistant rear access ArcGard arc-resistant front access


Arc faults can generate thermal energy as high as 35,000F and a Arc-resistant front-accessible switchgear from Eaton provides the
blast equivalent to 20.7 lbs of TNT. Arc-resistant gear is designed to robustness and strength of arc-resistant rear-accessible construction,
safely redirect and contain these arcs should they occur, regardless but with the flexibility of an innovative front-accessible design.
of the originating location of the arc. ArcGard Magnum DS switchgear This unique gear design allows for mounting against a wall, while
has been tested in all three compartments for a full 0.5 seconds, protecting operating and maintenance personnel from potentially
passing ANSI Type 2 and Type 2B standards at 100 kA at 508V and dangerous arcing events.
85 kA at 635V.

Short circuit withstand rating up to Short circuit withstand rating


85kAIC @ 635Vac max and up to up to 85kAIC @ 635Vac max
100kAIC @ 508Vac max and up to 100kAIC @ 508Vac
max
Up to 10,000A continuous current
horizontal main bus Up to 6,000A continuous
current horizontal main bus
Up to 5,000A continuous
current vertical riser bus Up to 5,000A continuous
current vertical riser bus
Type 2 & 2B
Type 2 & 2B
Plenum & direct venting available Type 2B secondary
compartment Plenum & direct venting
Clearance @ 10 floor-to-ceiling available
60 minimum line-up width Clearance @ 10 floor-to-ceiling
72 90 structure depth 66 minimum line-up width
Allowing drawout of breaker while Fixed 54-inch switchgear depth
maintaining type 2B approachability
rating Up to four-high breaker
arrangement
Venting system directs arc gasses
to top of the enclosure Breaker structures are 22 or
44 inches wide
Up to four-high breaker
configuration Cable compartments are 22,
30 or 44 inches wide
NEMA 1 enclosure, with either top
or bottom cable or bus duct entry NEMA1 indoor

EATON Low Voltage Switchgear 3


Automatic transfer and intelligent control packages
pre-engineered flexible smart

Low voltage switchgear


elevation and one line view

Eatons Magnum DS low voltage Features and benefits a switchgear assembly and
switchgear offers optional pre- continuously monitor and control
engineered automatic transfer Eaton ATC-900 controller various devices and parameters.
and intelligent control pack- This controller can be utilized The dashboard can be integral
ages with features that can for transfer in a lineup with to the switchgear assembly or
be modified to meet specific Main-Main, Main-Generator or remotely mounted offering a
requirements. The packages are GeneratorGenerator application monitoring and control option
available on both standard and (no tie breaker present). This outside the arc flash zone. It
arc-resistant switchgear as well option will include a selector provides features required to
as both front and rear access switch for Auto/Manual as well maintain a switchgear assembly
equipment. Classified by the as generator start/stop/exercise. such as:
interface, the automatic transfer
Eaton PLC with Eaton
Remotely open/close circuit
and intelligent control packages
touchscreen breakers through control mode
are as follows:
Using the Eaton PLC and Eaton Initiate a transfer scheme in a
Eaton ATC-900 controller touchscreen, Eaton can provide Main/Tie/Main switchgear for
Eaton PLC with Eaton automatic Main-Tie-Main transfer uninterrupted power supply
touchscreen to increase uptime and effi-
ciency. The desired sequence of Ability to configure/ monitor
Power Xpert dashboard operation can be selected during alarms for various devices
project quotation. Provides a rich interface to
monitor parameters of all
Power Xpert dashboard devices and study the trends
The Power Xpert dashboard is of those parameters.
an intelligent collection of views
which allow users to configure

For more information, visit


www.eaton.com/lva
or call your local Eaton sales office.

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

2015 Eaton
All Rights Reserved Eaton is a registered trademark.
Printed in USA
Publication No. BR019001EN / 828 All other trademarks are property
February 2015 of their respective owners.