Sie sind auf Seite 1von 3

CORE LOSS TESTER VCL

INTRODUCTION

Core loss testing has become one of the most important tests for quality assurance in the
motor industr y. The function of a core loss test is to determine weather a motor has
damaged core iron. Damage could include shorts between laminations and electrical
arching. Although it is possible for a motor to still run with damaged core but the efficienc y
of that motor will be greatly reduced. The Motor will consume more power to operate at
normal levels and it will cause the Motor to generate more heat. Heat will reduce the
reliability of the motor and its overall life. VEER make Core Loss Tester is portable & eas y
to use instrument which is ver y useful to measure AC mag netic properties of Electrical
steel of core of different grade and size. W e provide Free Computer software along with
instrument to create test report in computer.
KEY FEATURES

Direct Measurement of Watt/kg, Magnetizing Force (AT/cm) & Induction of core

Tampere proof calibration

Portable / Table Top Model

20 x 4 Bright LCD Display

Inbuilt Data Storage memory to store upto 500 Test Results

Computer interface with USB & RS-232 Serial Port

Free software to generate test report

Hold Facility to Freeze any test results

Easy to use

THEORY OF OPERATIONS

There are two windings primary and secondary, which have same number of turns. After calculating core
Area of core we can test it using this instrument by applying respected test Voltage as required for
specific Induction. We are measuring Current of Primary winding & Voltage from secondary winding to
find Losses(Watt / kg), Induction (Bm) & Magnetizing Force (At/cm) of Core.

APPLICATION

Motor and Pump manufacturer, Supplier, Rewinder and User.

Motor Stator, Rotor, Armature Core Manufacturer & Supplier.

Alternator Core manufacturer, Supplier, Repairer and User.

Electrical & Metallurgical Department of Engineering Institutes.

SPECIFICATIONS

SPECIFICATIONS
Model VCL-01 VCL-02 VCL-03 VCL-05 VCL-10
Voltage Range 5V 6V 5V 5V, 15V 5V, 15V
Current Range 200A 300A 600A 333A, 1000A 2000A, 666A
Sourcing Capacity
1000 1800 3600 5000 10000
In VA
W att/kg, Magnetizing Force (AT/m), Flux Density (Induction in
Parameters
Tesla), Flux Volt, RMS Amp, Peak Amp, Power, Frequenc y etc.
0.2% FSD 5digit for Voltage, Current & W att, 0.05% of
Accuracy
reading for Frequenc y
AC 230V 10% @ 50 Hz OR AC 110V 10% @ 60 Hz (On
Power Supply
Request)
Power
Less than 50VA for No Load condition
Consumption
Dimensions ( W x D
450mm x 350mm x 1000mm approx. ( VCL -02)
x H ) in mm
Weight of
75 kg approx.(for VCL-02)
Instrument
1 Year against manufacturing defects & Extended optional. No
Warranty
W arranty for accessories.