Sie sind auf Seite 1von 15

PRODUCT VALIDATION REPORT FOR LED LUMINAIRES

Product Name : 50W FLOOD LIGHT Sample Recd. Date :


Manufacturer (Fixture / Driver) : HAVELLS Sample Ref No :
Qty : Report Prep Date : :20/7/2017
Class (Fixture / Driver) : Ambient Temp : :25 C
Operating Temp. Range : Category :PLUM(Outdoor)

EXECUTIVE SUMMARY

Summary Of Tests
(1) Optical Test PASS

(2) IP Test PASS

(3) Electrical Test : PASS

(4) Fault Conditions Test : PASS

(5) Continuous Ageing Test PASS

(6) Safety Tests PASS

(7) EMC Test : Immunity (Surge & Voltage Dips Interruptions) PASS

(8) Thermal Test PASS

(9) Endurance Test PASS

Major Observations & Corrective Actions :


1.Lumen output is below the limit provided

Gonio Report is required for confirmation

2.Initially input power was low.Then the value of Shunt Resistors R3,R4,R5,R6 were changed to 1E,0.25W 1206

3.Tj is very slightly above the limit (Should be within the limits)

Minor Observations & Corrective Actions :


2 way screw connector at driver output side was found loose.

Connector should be soldered properly to avoid disconnection between led module and driver output

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 1
All Tests have been Performed As Per Concerned IEC and IS Standards
IEC Description
IEC 62384 DC or AC Supplied Electronic Control Gear for LED Modules Performance Requirements
IEC 61347-2-13
DC or AC Supplied Electronic Control Gear for LED Modules Safety Requirements

IEC 61547 DC or AC Supplied Electronic Control Gear for LED Modules Immunity Requirements
IEC 61000-4-2 ESD Immunity Test

IEC 61000-4-4 Electrical Fast transient

IEC 61000-4-5
Surge Immunity Test
IEC 61000-4-11
Voltage Dips & Short Interruptions

IEC 61000-3-2 DC or AC Supplied Electronic Control Gear for LED Modules Harmonics Requirements
IEC 62384
DC or AC supplied electronic control gear for LED modules Endurance & Thermal requirements

IEC 60598-1:2014 Luminaires- Part 1: General Requirements and Tests

IS

IS 15885 (Part2/Sec13) : 2012 Safety of Lamp Control Gear Part 2 Particular Requirements Section 13 d.c. or a.c. Supplied Electronic Controlgear for Led Modules

IS 16102(Part 1 & 2) : 2012 Self- Ballasted LED Lamps for General Lighting Services Part 1 Safety Requirements and Part 2 Performance Requirements

IS 16103(Part 1 & 2) : 2012 Led Modules for General Lighting Part 1 : Safety Requirements and Part 2 : Performance Requirements

IS 16104 : 2012 d.c. or a.c. Supplied Electronic Control Gear for LED Modules - Performance Requirements

IS 16105 : 2012 Method of mesurement of Lumen Maintenance for SSL Product

IS 16106 : 2012 Method of Electrical and Photometric Measurement for SSL Product

IS 16107 : 2012 Luminaires Performance Part 1 General Requirements and Part 2 Particular Requirements Section 1 LED Luminaire

IS 10322 : 2014 Luminaires General Requirements and Tests

IS 11000 : (Part 2 / Sec 1) Glow Wire test

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 2
S.No. Technical Data
Particulars NPI Data Observed Data
Integrated
Instrument Used Sphere
Gonio

Optical Parameter
1 Luminous Flux (Lumen) 4790.7
2 Luminous Efficacy (Lm / W) 104.16
3 CRI 73.8
4 SDCM 7.6
5 CCT (K) 5922
6 Beam Angle and Geometry
7 Flicker Index
8 Flicker Freq. (Hz)
9 Flicker Percentage (%)
10 Operating Supply Range, AC
11 Stabilization Period : T=0 T1= 45min
12 Rated Supply Voltage 240.05 243.73
13 Input Current (mA) 0.2052 0.1979
14 Input Power (W) (IS 16104 / IEC 62384) 48.32 47.2
15 Power Factor (P.F.) (IS 16104 / IEC 62384) 0.981 0.979
16 Mains Frequency (Hz) 50 50
17 V THD (%) (IEC61000-3-2)
18 I THD (%) 4.88 5.16
19 I THD Level 3rd (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2) 1.39 1.04
Electrical Parameters

20 I THD Level 5th (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2) 2.61 2.38
21 I THD Level 7th (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2) 1.03 0.93
22 I THD Level 9th (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2) 2.19 1.97
23 I THD Level 11th (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2) 0.46 0.39
24 Output Voltage (V) 36.18 35.9
25 Output Current (mA) 1.195 1.157
26 Output Power (W) 42.68 41.54
27 Efficiency (%) 0.883 0.88
28 Driver Losses (W) 6.26 5.89
29 Voltage / LED (V) 5.98
30 Maximum Output Current Peak (Irms Hi in Amp) 0.223 0.222
31 Ripple Factor (%) 19.28%
32 Open Ckt Voltage (Voc) in (V) @ 240V (IS 15885-2-13 Amend 1) 41.46
33 Starting Voltage of Luminaire (V) 51V
34 APFC Range of Luminaire (O/P CC Range) 140-270V
35 Input voltage AC Over Voltage cutoff 308V
36 cutoff Low Voltage cutoff not provided
37 Output Short Circuit Protection (IS 16104 Cl 12c / IEC 62384) provided
38 O/P Reverse Polarity Protection provided
Immunity or
protections

39 Inrush Current Protection Test (At Max Operating Voltage of Luminaire) provided
40 Open Circuit Protection w/o Load (for 15 min) provided
41 Operation of Luminaire @ 440V Protection for 2 hrs Pass
42 Surge Voltage Protection in Diff, CM Mode (IEC 61000-4-5 / IEC 61547) Pass
43 Voltage Dips & Interruption test (IEC 61000-4-11 / IEC 61547) Pass
44 IP Duty (Fixture / Driver) (IS 10322 Part I / IEC 60598-1) Pass
Contin

45 Low Voltage Ageing @ 120V for 8 Hrs Pass


Agein
uous

46 High Voltage Ageing @ Max Operating Voltage of Luminaire for 8 Hrs Pass
47 Humidity Test (IS 10322 Part I / IEC 60598) Pass
48 HV Test @ (1.5KV Class-I ; 3.75KV Class II) for 1 min (IS 10322 Part I / IEC 60598-1) Pass
Safety

49 Insulation Resistance (Class I > 2 M ; Class II > 4 M at 500VDC (IS 10322 Part I) Pass
50 Leakage Current (Class I < 0.5mA ; Class II < 1.0mA) - (IS 10322 Part I) Pass
51 Isolation of LED Driver @ 3.75KV for 1 min @ Tripping Current 5 mA (IEC 61347-2-13/ 61347-1) Pass
52 Flammability Test for Plastic Parts (IS 10322 - Part I) Pass
53 Wireways Smooth and Free from Sharp Edges (IEC 60598) YES
54 Insulating Lining and Sleeves Used (IEC 60598) YES
55 Switches of Adequate Rating if used (IEC 60598) N/A
56 Screws Used (IEC 60598) Philip head screws
57 Screw Locking (IEC 60598) Spring Washer
Construction

58 Impact Test Fragile Parts (IS 62262) Not Available


59 Suspension Fixing Means of Adjusting Load Test (IEC 60598) Not Available
60 Resistance to Corrosion (IEC 60598) Not Available
61 Vibration Test for Rough Service Luminaire (IS 10322) Not Available
62 Creepage and Clearances (IEC 60598-1) Pass
63 Earthing Resistance Not Available
64 Type of Attachment --- X/Y/Z marking should be on the cable Not Mentioned
65 Pull Test for External Wiring(IS 10322 Part 1) Not Available

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 3
APFC Range (CC Range)
180
Vin Iin Pin P.F. Vout Iout Pout Efficiency
0.995
100 0.5023 50.31 0.995 35.8 1.1428 40.91 81%
0.99
120 0.405 48.77 0.995 35.8 1.1452 40.99 84%
0.985
140 0.3453 47.98 0.996 35.79 1.1459 41.01 86%
0.98
160 0.2964 47.34 0.996 35.79 1.1642 41.14 87%
0.975
180 0.2631 46.99 0.994 35.78 1.1657 41.16 87%
0.97
200 0.2363 46.7 0.991 35.76 1.1644 41.08 88%
0.965
220 0.2135 46.5 0.985 35.76 1.1653 41.09 85%
0.96
240 0.1973 46.48 0.979 35.75 1.1644 41.06 85%
0.955
260 0.1832 46.35 0.972 35.74 1.1631 41.03 89%
170 0.95
280 0.1714 46.35 0.963 35.74 1.1638 41.04 89% 100 120 140 160 180 200 220 240 260 280

300 0.1612 47.35 0.953 35.72 1.1846 41.87 88%


Power Fa ctor O/P Curre nt

5) Endurance And Thermal Test (IEC 60598 / 62384)

5.1) Endurance Test Test Results / Remarks

1 Temperature Cycling Test Non Energized Control Gear For 5 Times (EN 62384) Not Available
Endurance Of Led Driver (Control Gear Shall Be Switched On & Off For 30 Seconds,200 Cycle w/o load and 800
2 cycle with load) - (EN 62384 / IS 16104 Sec 13.1) Pass
Control Gear Shall Be Operated With An Appropriate LED Module
3 Not Available
At The Ambient Temperature Which Produce Tc, Until A Test Period Of 200Hrs- (IS 16104 Clause 13.1)
4 Endurance of Fixture at Ta+10C @ 21 hrs ON / 3 hrs OFF (IS 10322 Part I / IEC 60598) Pass

5.2) Thermal Measurement of Luminaire & LED Driver Critical Components (IEC 60598)

S.No. Particulars Max.Temp. limit (C) Observed Value @ 45 (C) Remarks

5.2.1) Luminaire :
1 Soldering Temp (Ts) 92.7
2 Junction Temp (Tj) <100 101.54
3 Heat Sink Not Mentioned 82.1
4 Glass Not Mentioned 71.3

5 Lens Not Mentioned 77.1

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 4
7) Physical Test Report :

Content Picture Observations Corrective Actions

Fixture is suitable for mounting with the help of U-


Front / Rear View
shaped clamp provided at the rear side.
of Fixture Grey coloured AL-PDC housing is used.

Total 12 LED's (2 parallel combinations of 6 led's


in series is used)
LED Module /
Make-Osram
Thermal Paste Model-GW P7LT32.PM
Driver output wires are directly soldered to MCPCB

Promptec make constant current isolated LED


driver is used.
LED Driver / SPD 3 way connector is used at input side while 2 way
connector is used at output side.
Connector at the output side was found loose

Fixture and Driver


Mounting

Glass / Diffuser / Black polished glass is used."HAVELLS" is


Lens / Gasket / printed over the glass.
Sceondary Optics / Glass is fixed to housing with the help of 4 no od
Reflector philips head screws

Connectors and
Internal Wiring /
Cable

M12 plastic gland is used.3 core cable (0.75 sq


mm) enters into the fixture via gland.
Earthing is provided via screw and stud
arrangement

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 5
Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 6
7) Physical Dimensions

Particulars Fixture Driver Remarks


Length (mm) 241 155

Width (mm) 150 35

Height(mm) 42 26

Pole Dia / CD (mm) 100-160 146*24


Earthing 142*24
Weight (Kg) 1.53

8) LED Specifications 9) Material Specifications

Make Osram Heat Sink / Housing AL-PDC

Model / Part No. GW P9LT32.PM Reflector N/A

Forward Voltage 6-6.6V Front frame N/A

Forward Current 710-820mA LED PCB MCPCB

CRI >70 Gasket Silicon

CCT(K) 5700K Gland M12-Plastic Gland

Led Driver PCB FR-4 Lens (Part Number / Beam Angle) LEDLINK-(92*139(FWHM*FWTM))

Note : ABS material should pass Glow Wire test at 650C

: Poly Carbonate material should pass Glow Wire test at 950C

Instruments Used :

S.No Description

1 LED Power Driver Tester, UI2050 Volnic Make

2 Power source VPS 1030; make Everfine

3 SpectroPhotocolorimeter PMS 80, Everfine Make

4 Hafely EMC Technology Impulse module.

5 8- Channel, Temperature Scanner Logger, Countron make

Results:

Tested and Prepared By : YASH KALRA

Approved By : Subrata Dutta

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 7
HAVELLS INDIA LTD

PRODUCT VALIDATION REPORT FOR LED LUMINAIRES


Product Name : Sample Recd. Date :
Manufacturer (Fixture / Driver) : Sample Ref No :
Qty : Report Prep Date :
Class (Fixture / Driver) : Ambient Temp :
Operating Temp. Range : Category : CLUM / PLUM

EXECUTIVE SUMMARY

Summary Of Tests
(1) Optical Test PASS / FAIL

(2) IP Test PASS / FAIL

(3) Electrical Test : PASS / FAIL

(4) Fault Conditions Test : PASS / FAIL

(5) Continuous Ageing Test PASS / FAIL

(6) Safety Tests PASS / FAIL

(7) EMC Test : Immunity (Surge & Voltage Dips Interruptions) PASS / FAIL

(8) Thermal Test PASS / FAIL

(9) Endurance Test PASS / FAIL

Major Observations & Corrective Actions :


1) xxxxxxxxxxxxx

---->yyyyyyyyyy

Minor Observations & Corrective Actions :


1) xxxxxxxxxxxxx

---->yyyyyyyyyy

Front view of Fixture Rear View of fixture

Driver

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 8
HAVELLS INDIA LTD

All Tests have been Performed As Per Concerned IEC/IS Standards


IEC 62384 DC or AC Supplied Electronic Control Gear for LED Modules Performance Requirements
IEC 61347-2-13
DC or AC Supplied Electronic Control Gear for LED Modules Safety Requirements

IEC 61547 DC or AC Supplied Electronic Control Gear for LED Modules Immunity Requirements
IEC 61000-4-2 ESD Immunity Test
IEC 61000-4-4 Electrical Fast transient
IEC 61000-4-5
IEC 61000-4-11
Surge Immunity Test
Voltage Dips & Short Interruptions

IEC 61000-3-2 DC or AC Supplied Electronic Control Gear for LED Modules Harmonics Requirements
IEC 62384
DC or AC supplied electronic control gear for LED modules Endurance & Thermal requirements

IEC 60598-1:2014 Luminaires- Part 1: General Requirements and Tests

IS 15885 (Part2/Sec13) :
2012 Safety of Lamp Control Gear Part 2 Particular Requirements Section 13 d.c. or a.c. Supplied Electronic Controlgear for Led Modules
IS 16102(Part 1 & 2) :
2012
Self- Ballasted LED Lamps for General Lighting Services Part 1 Safety Requirements and Part 2 Performance Requirements
IS 16103(Part 1 & 2) :
2012
Led Modules for General Lighting Part 1 : Safety Requirements and Part 2 : Performance Requirements

IS 16104 : 2012 d.c. or a.c. Supplied Electronic Control Gear for LED Modules - Performance Requirements

IS 16105 : 2012 Method of mesurement of Lumen Maintenance for SSL Product

IS 16106 : 2012 Method of Electrical and Photometric Measurement for SSL Product

IS 16107 : 2012 Luminaires Performance Part 1 General Requirements and Part 2 Particular Requirements Section 1 LED Luminaire

IS 10322 : 2014 Luminaires General Requirements and Tests


IS 11000 : (Part 2 / Sec
1)
Glow Wire test

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 9
HAVELLS INDIA LTD

S.No. Technical Data


Particulars NPI Data Observed Data
Integrated
Instrument Used Sphere
Gonio

Optical Parameter
1 Luminous Flux (Lumen)
2 Luminous Efficacy (Lm / W)
3 CRI
4 SDCM
5 CCT (K)
6 Beam Angle and Geometry
7 Flicker Index
8 Flicker Freq. (Hz)
9 Flicker Percentage (%)
10 Operating Supply Range, AC (IS 16102 - II)
11 Stabilization Period : T=0 T1= 45min
12 Rated Supply Voltage (IS 16102 - II)
13 Input Current (mA) (IS 16104)
14 Input Power (W) (IS 16102)
15 Power Factor (P.F.) (IS 16104)
16 Mains Frequency (Hz) (IS 16102 - II)
17 V THD (%) (IEC61000-3-2 / IS 16104)
18 I THD (%) (IEC61000-3-2 / IS 16104)
19 I THD Level 3rd (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2)
Electrical Parameters

20 I THD Level 5th (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2)
21 I THD Level 7th (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2)
22 I THD Level 9th (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2)
23 I THD Level 11th (mA/W for Pin 25W & % for Pin>25W) (IEC61000-3-2)
24 Output Voltage (V) (IS 16104 )
25 Output Current (mA) (IS 16104 )
26 Output Power (W)
27 Efficiency (%) (IS 16102 - II)
28 Driver Losses (W) (IS 16102 - II)
29 Voltage / LED (V) (IS 16102 - II)
30 Maximum Output Current Peak (Irms Hi in Amp) (IS 16102 - II)
31 Ripple Factor (%)
32 Open Ckt Voltage (Voc) in (V) @ 240V (IS 15885-2-13 Amend 1)
33 Starting Voltage of Luminaire (V)
34 APFC Range of Luminaire (O/P CC Range)
35 Input voltage AC Over Voltage cutoff
36 cutoff Low Voltage cutoff
44 IP Duty (Fixture / Driver) (IS 10322 Part I / IEC 60598-1)
tio
un
ity
Im

ns
ec
or
pr
ot
m

37 Output Short Circuit Protection (IS 16104 Cl 12c)


38 O/P Reverse Polarity Protection
39 Inrush Current Protection Test (At Max Operating Voltage of Luminaire)
40 Open Circuit Protection w/o Load (for 15 min)

APFC Range (CC Range)


180
Vin Iin Pin P.F. Vout Iout Pout Efficiency
0.995

100
0.99

120
0.985

140
0.98

160
0.975

180
0.97

200
0.965

220
0.96

240
0.955

260
170 0.95
100 120 140 160 180 200 220 240 260 280

280

300 Power Factor O/P Curre nt

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 10
HAVELLS INDIA LTD

Contin
45 Low Voltage Ageing @ 120V for 8 Hrs

Agein
uous

g
46 High Voltage Ageing @ Max Operating Voltage of Luminaire for 8 Hrs
43 Voltage Dips & Interruption test (IEC 61000-4-11 / IEC 61547)

Safety
47 Humidity Test (IS 10322 Part I / IEC 60598)
48 HV Test @ (1.5KV Class-I ; 3.75KV Class II) for 1 min (IS 10322 Part I / IEC 60598-1)
49 Insulation Resistance (Class I > 2 M ; Class II > 4 M at 500VDC (IS 10322 Part I)
50 Leakage Current (Class I < 0.5mA ; Class II < 1.0mA) - (IS 10322 Part I)
51 Isolation of LED Driver @ 3.75KV for 1 min @ Tripping Current 5 mA (IEC 61347-2-13/ 61347-1)
42 Surge Voltage Protection in Diff, CM Mode (IEC 61000-4-5 / IEC 61547)
52 Flammability Test for Plastic Parts (IS 10322 - Part I)

5.2) Thermal Measurement of Luminaire & LED Driver Critical Components (IEC 60598)

S.No. Particulars Max.Temp. limit (C) Observed Value @ ta (C) Remarks

5.2.1) Luminaire :
1 Soldering Temp (Ts)

2 Junction Temp (Tj)

3 Heat Sink

4 Glass

5 Lens

5.2.2) LED Driver Components :

1 LED Driver Casing (Tc)

2 Output Diode Not Available

3 Driver Output Wire Not Available

4 Transformer Winding 100

5 Transformer Core 100

6 Driver Input Wire Not Available

7 MOSFET Not Available

8 Device IC (U1) N/A

9 Output ELCO Not Available

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 11
HAVELLS INDIA LTD

6) IR Image of LED Driver Comonents

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 12
HAVELLS INDIA LTD

5) Endurance And Thermal Test

5.1) Endurance Test NPI Data Test Results / Remarks

1 Temperature Cycling Test Non Energized Control Gear For 5 Times (EN 62384)

Endurance Of Led Driver (Control Gear Shall Be Switched On & Off For 30 Seconds,200 Cycle w/o load and 800
2 cycle with load) - (EN 62384 / IS 16104 Sec 13.1)

Control Gear Shall Be Operated With An Appropriate LED Module


3
At The Ambient Temperature Which Produce Tc, Until A Test Period Of 200Hrs- (IS 16104 Clause 13.1)

4 Endurance of Fixture at Ta+10C @ 21 hrs ON / 3 hrs OFF (IS 10322 Part I)

5 Operation of Luminaire @ 440V Protection for 2 hrs

53 Wireways Smooth and Free from Sharp Edges (IEC 60598)


54 Insulating Lining and Sleeves Used (IEC 60598)
55 Switches of Adequate Rating if used (IEC 60598)
56 Screws Used (IEC 60598)
57 Screw Locking (IEC 60598)
Construction

58 Impact Test Fragile Parts (IS 62262)


59 Suspension Fixing Means of Adjusting Load Test (IEC 60598)
60 Resistance to Corrosion (IEC 60598)
61 Vibration Test for Rough Service Luminaire (IS 10322)
62 Creepage and Clearances (IEC 60598-1)
63 Earthing Resistance
64 Type of Attachment --- X/Y/Z marking should be on the cable
65 Pull Test for External Wiring(IS 10322 Part 1)

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 13
HAVELLS INDIA LTD

7) Physical Test Report :

Content Picture Observations Corrective Actions

Front / Rear View


of Fixture

LED Module /
Thermal Paste

LED Driver / SPD

Fixture and Driver


Mounting

Glass / Diffuser /
Lens / Gasket /
Sceondary Optics /
Reflector

Connectors and
Internal Wiring /
Cable

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 14
7) Physical Dimensions

Particulars Fixture Driver Remarks


Length (mm)

Width (mm)

Height (mm)

Pole Dia / CD (mm)

Earthing

Weight (Kg)

8) LED Specifications 9) Material Specifications


Make Heat Sink / Housing

Model / Part No. Reflector

Forward Voltage Front frame

Forward Current Glass

Wattage/LED LED PCB

Lumens Heat Sink Compound

CRI Gasket

CCT(K) LED Driver PCB


Thermal Resistance
Gland
(C/W)
Lens (Part Number / Beam Angle)

Note : ABS material should pass Glow Wire test at 650C

: Poly Carbonate material should pass Glow Wire test at 950C

Instruments Used
LED Power Driver Tester, UI2050 Volnic Make
Power source VPS 1030; make Everfine
Spectro Photocolorimeter PMS 80, Everfine Make
Hafely EMC Technology Impulse module.
20- Channel, Temperature Scanner Logger, Agilent make
Flicker Meter - MF250N

Results:

Tested and Prepared By : Approved By : Subrata Dutta

Havells India Ltd., Center For Research Innovation, 2d, Sector 126, Noida 201 304, INDIAfile:///conversion/tmp/scratch/364203579.xlsx 15

Das könnte Ihnen auch gefallen