Sie sind auf Seite 1von 6

Tankless Heater

Sizing Calculator
200 50 140 kW
Sizing Based on Water Temperature and Flow Rate
180 45 120 kW
Temprature Change (T) Required for an Application
160 40
100 kW
140 35
Input Value
120 80 kW
Incoming Water Temp. 30
100 60 kW
Desired Process Temp. 25
Temperature Rise (T ) F = [Desired Temp] - [Incoming Temp] 80
20 40 kW
Flow Rate 60
15
Power Required = GPM * T * [Heater Series] 40 20 kW
10
20 Power
kW Required To Reach Temp
5
Standard Unit Size 0
Incoming Desired 0
Water Process Flow Rate
Temp. Temp.

Calculations for Downsizing or Choosing Alternate Heaters


Adjust Flow Rate to Achieve Temperature Rise Adjust Temperature Rise to Achieve Flow Rate

Input Value Input Value


kW kW Input
GPM Delta T

Temperature Rise = kW * 6.824 / GPM Max. Flow at Temp = kW * 6.824 / T


Unit Conversion
British Thermal Unit (BTU) <-> kW

BTU to kW kW to BTU
BTU kW
kW BTU

Convert Temperature

C to F F to C
C F
F C

Calculate Delta-T Fahrenheit from Celsius

Input Value
Incoming Water Temperature C
Desired Process Temperature C

Delta-T Fahrenheit F

Convert Horsepower to kW

HP to KW
HP HP
kW kW
Calculate Max Amp-Draw From kW and Voltage

3 Phase Single Phase


kW kW kW kW
Voltage Volts Voltage Volts
Amp Draw Amps Amp Draw Amps

Calculate Power Ratio for Downrating applications

Input Value
Original Design Unit Voltage Volts
New Service Voltage Volts

Power Ratio
Calculate Effective kW in Downrated Applications
from Power Ratio Calculator

Input Value
Rated kW Output at Advertised Voltage kW

Actual kW Output kW
Mixing Valve Flow Bias Calculator
Input Value
Cold Water Temperature F Max Hot Water Flow Rate for
Hot Water Temperature F Minimum Flow Rate Required
Mixed Temperature F
Mixed Flow Rate - Single Fixture GPM
Number of Fixtures

Hot Water Flow Rate GPM


Cold Water Flow Rate GPM
Calculator

Hot Water Flow Rate for Application GPM


um Flow Rate Required for Activation GPM