Sie sind auf Seite 1von 2

175 WATT N/ERCURY VAPOR

M3311

1. Medium base socket B. Adjustable square plaster ring


2. Extruded aluminum heat sink
is mounted to lrame to allow
lor heal dissipalion adjustment according to
ceilino depth up to 1" from
3. Veni holes below the ceiling
4.8" low brighlness black baflle 9. Baflle and hoLrsing held with
and housing tension springs-2 ways
5. 175W. R40 10. Die formed lrame is
6. Ballast and splice box constructed of '16 GA.
assembly CWA HPF accessible galvanized steel
from below the ceiling 11. 2 27" long mounting bars
7. Double-faced junction box 1 2. Slotied adlustment for
mountinq bars

Housing Recessed Trim Type of


Design
Numbet Dimensions widrh Length Height Oimensions Lamp

175W
M3311 8%" Square 91/t" 23va' 13" 9Tr" Square R40 Coated
Specily Voltage Required Bafile ls finished in 3M Nexlel Black

S PECIFICATIONS
Low brightness downlight utilizing a sharply defined allow a maximum of 1" of movement lo compensate
groove in a square 8" ba{fle with a long ljfe coated for ceilinq construction. Frame is furnished with
mercury "R" lamp provides a widespread distributjon double-faced junction box and is completely pre-
of light with minimum brighlness. Baffle and housing wired.
maintained in unit by two tension springs to assure Fixture is wired with 200'C. SF2 Silicone wire and
ease of inslallation. nickel-plated screw shell socket. Aluminum conduit
Encased and potted constant wattage autotrans- allows total flexibility. Porcelain socket is housed in
former ballast carries a "B" sound rating on a scale pure aluminum heat sink for effective heat dissipation.
ol "A" thru "F", and is guaranteed lor two years of Labels
normal service with free replacement and installa- Underwriters listed, damp location, through branch
tion if due to faulty workmanship or material. Ballast circ u it wiring, l.B.E.W.
is completely accessible from below ceiling line and
can be mounted remote if desired. Note
The 1 6 GA. qalvan ized steel strength f rame is Fixture is shipped fully assembled and pre-wired.
f urnished f or installation with lwo 10 GA. 27" long Baffle and Housing separately protected to prevent
mounting bars. Cut-outs on end of frame allows for damage durjng installatjon and finishing of ceiling.
complete flexibility of mounting bars or lathing Keyhole slotted top allows ease of installation to
channel (by others). lnner plaster ring is slotted to heat sink. M
43
O COPYEIGHT OCT. 1 975, N L CORPOBATION . ] 4901 BsOADWAY, CLEVELANO, OHIO 441 37
Certilied Test Report No. ERL 1400
NL Corp. Recessed Downlight, Cat. No.3311
One GE H175RFL39-22 175w Mercury Lamp, Rated 5700 Lumens

Average Luminance Data Luminance Summary-Footlambens


Foollamberts Angle Average FL
Angle Luminance 45 2736
0 35246 50 1189
30 15022 55 320
40 5527 60 84 Total Lumens
45 2736 65 46
Zone Lumens Percent
50 11a9 70 I
55 320 75 0 0-40 2815 49.39
60 B4 80 0 0-60 3049 53.50
65 85 0 0-90 30s1 53.s4
70 I
75 0
80 C"nified Test Reporl No. ERL t4ff)
85 I"
NL Corp. Becessed Oownlight, Cat. No.3311
One GE Hl75RFL39-22 175W. Mercury Lamp, Rated 5700 Lumens
coefficients 0f utilization
: .20
Effective Floor Cavity Rellectance
cc80 70 5030 l00
Wall 70 50 30 10 70 50 30 't0 50 30 l0 50 30 t0 50 30 10 0
RCR
1 .61 .60 .59 .58 .60 .59 .58 .57 .57 .56 .s5 .55 .54 .54 .53 .52 .52 .51
2 .59 .57 .55 .53 .58 .56 .s4 .53 .54 .53 .52 .53 .52 .51 .51 .50 .50 .49
3 .57 .54 .52 .50 .56 .53 .51 .50 .52 .50 .49 .51 .49 .48 .49 .48 .47 .47
4 .54 .51 .49 .47 .54 .51 .48 .47 .49 .48 .46 .44 .47 .4$ .47 .46 .45 .44
5 .52 .49 .46 .44 .51 .4a .45 .44 .47 .45 .43 .46 .44 .43 .45 .44 .43 .42
6 .50 .46 .44 .42 .49 .46 .43 .41 .45 .43 .41 .44 .42 .41 .44 .42 .41 .40
7 .4a .44 .41 .39 .47 .43 .41 .39 .43 .40 .39 .42 .40 .39 .42 .40 .38 .38
a .46 .42 .39 .37 .45 .41 .39 .37 .41 .38 .37 .40 .38 .37 .40 .38 .36 .36
s/MH : .8 L44 .39 .37 .35 .43 .39 .37 .35 .39 .36 .35 .38 .36 .34 .38 .36 .34 .34
MED. SPREAD 10 .42 .37 .35 .33 .41 .37 .35 .33 .37 .34 .33 .36 .34 .33 .36 .34 .33 .32

Number ol Luminaires Required lor 30.0 and 70.0 FC. Candlepower Oata Candlepower Summary
Lighl Loss Faclor: .75 See Footnote Angle Candlepower Lumens Angle Average CP
-
Cc, Wall + FC Relleclances: 80, 50, 20 0 4170 0 4170
Work Plane Height = 2.5 Feet 5 3990 377 5 3990
10 10 3667
Room 30.0 Footcandles 70.0 Footcandles
Dimensions Height
15 3184 8BB 15 3184
Height 20 2495 20 2495
WL 8.s 10.0 13.0 16.0 8.5 10.0 13.0 16.0
25 1976 924 25 1976
20 20 556 6 12 13 14 '15 30 1539 30 '1539
20 30 888 I 18 18 20 21 35 973 626 35 973
20 40 10 10 11 12 23 24 26 27 40 501 40 501
20 60 15 15 16 17 35 36 37 39 45 228 203 45 228
s0
30 20 8BB I 18 1A 20 2l 50 90
22
50
22
30 30 11 11 12 13 26 27 28 30 55 31
5
30 40 15 15 16 34 35 37 38 60 5
22
60
30 60 22 22 23 24 50 52 54 56 65 65 2
30 80 29 29 30 32 67 6a 71 74 70
75
0
00
70
75
0
0
40 20 10 10 11 12 23 24 26 27 BO 0 BO 0
40 30 15 15 '16 16 34 35 37 38 85 00 85 0
40 40 19 20 20 21 45 46 48 50 90 0
40 60 2A 29 30 66 68 70 72
40 80 38 38 39 41 88 89 92 95 Total Oulpul
40 100 47 48 49 50 110 111 114 118 Zone Lumens Percent
60 30 22 22 23 24 50 52 54 56 0-40 2a15 49.39
60 40 28 29 30 66 68 70 72 0-60 3049 53.50
60 60 42 43 44 45 98 100 102 105 o-70 3051 53.54
60 80 57 56 58 133 132 135 138 0-90 3051 53.54
60 100 72 70 72 167 164 167 171 40-90 236 4.15
100 40 47 4a 49 50 110 111 114 118 60-90 2 .04
100 60 72 70 72 167 164 167 171 70-90 0 .00
100 80 97 95 95 96 226 222 221 225 90-180 0 0.00
'100 100 122 120 117 119 245 241 274 278 0-180 3051 53.s4

For other light loss factors: Tested in Accordance with IES procedures.
No. ot luminaires required = No. lrom table X.7slNew LLF Test distance exceeds 25 leet.
M
44
ocopyRrcHTocr.lgTs, NL coRPoRATloN .14901 B RoADWAy, cLEVELAN D, oH to 44137