Sie sind auf Seite 1von 52

Operating Manual

(Translation of the original German Operating Manual)

PacDrive
SCL-055
07.2013
Imprint

The information provided in this documentation contains general descriptions and/or


technical characteristics of the performance of the products contained herein. This
documentation is not intended as a substitute for and is not to be used for determining
suitability or reliability of these products for specific user applications. It is the duty of
any such user or integrator to perform the appropriate and complete risk analysis,
evaluation and testing of the products with respect to the relevant specific application
or use thereof. Neither Schneider Electric nor any of its affiliated or subsidiary com
panies are responsible or liable for a misuse of the information contained herein. If you
have any suggestions for improvements or amendments or have found errors in this
publication, please notify us.
No part of this document may be reproduced in any form or by any means, electronic
or mechanical, including photocopying, without express written permission of Schneid
er Electric.
All pertinent state, regional, and local safety regulations must be observed when in
stalling and using this product. For reasons of safety and to help ensure compliance
with documented system data, only the manufacturer should perform repairs to com
ponents.
When devices are used for applications with technical safety requirements, the rele
vant instructions must be followed.
Failure to use Schneider Electric software or approved software with our hardware
products may result in injury, harm, or improper operating results.
Failure to observe this information can result in injury or equipment damage.
2013 Schneider Electric. All rights reserved.

2 PacDrive SCL-055 Schneider Electric


Contents

Contents

1 About this manual 5


1.1 Introduction ............................................................................................................... 5
1.2 Symbols, designator and display format of safety messages .................................. 5

2 Safety information 7
2.1 Proper use ................................................................................................................ 7
2.2 Qualification of Personnel ........................................................................................ 8
2.3 Residual risks ........................................................................................................... 8

3 System overview 13

4 Indicators and control elements 15


4.1 Example of a diagnostic message .......................................................................... 17

5 Transport, storage, unpacking 18


5.1 Transport ................................................................................................................ 18
5.2 Storage ................................................................................................................... 18
5.3 Type plate ............................................................................................................... 18
5.4 Type code ............................................................................................................... 20

6 Installation and maintenance 21


6.1 Commissioning ....................................................................................................... 21
6.1.1 The PacDrive SCL-055 with the "positive pressure" option .................................... 22
6.1.2 Preparing commissioning ....................................................................................... 23
6.1.3 Setting the SERCOS address ................................................................................ 23
6.1.4 Slaves in sercos loop ............................................................................................. 23
6.1.5 Cabling ................................................................................................................... 25
6.2 Configuration, homing and programming ............................................................... 26
6.3 Electromagnetic compatibility, EMC ....................................................................... 27
6.4 Maintenance, repair, cleaning ................................................................................ 28
6.4.1 Repair ..................................................................................................................... 28
6.4.2 Cleaning ................................................................................................................. 28
6.5 Spare part inventory ............................................................................................... 29

Schneider Electric PacDrive SCL-055 3


Contents

6.6 Device-, parts- or cable exchange .......................................................................... 29


6.6.1 Device replacement ................................................................................................ 31
6.6.2 Cable replacement ................................................................................................. 32

7 Technical data 36
7.1 Definition of technical data ..................................................................................... 36
7.2 Mechanical and electrical data ............................................................................... 37
7.2.1 PacDrive Controller SCL-055 ................................................................................. 37
7.2.2 Technical Data - PacDrive SCL-055 30 011 and SCL-055 15 010 ........................ 38
7.2.3 Encoder .................................................................................................................. 38
7.2.4 Motor shaft and bearings ........................................................................................ 39
7.3 Mounting arrangement and degree of protection ................................................... 41
7.4 Torque/speed characteristic curves ....................................................................... 42
7.5 Electrical connections ............................................................................................. 44
7.6 Dimensions ............................................................................................................. 45

8 Appendix 47
8.1 Contact addresses ................................................................................................. 47
8.2 Product training courses ......................................................................................... 47
8.3 EC declaration of conformity .................................................................................. 48
8.4 Changes ................................................................................................................. 49
8.5 Units and conversion tables ................................................................................... 50
8.5.1 Length .................................................................................................................... 50
8.5.2 Mass ....................................................................................................................... 50
8.5.3 Force ...................................................................................................................... 50
8.5.4 Power ..................................................................................................................... 50
8.5.5 Rotation .................................................................................................................. 50
8.5.6 Torque .................................................................................................................... 51
8.5.7 Moment of inertia .................................................................................................... 51
8.5.8 Temperature ........................................................................................................... 51
8.5.9 Conductor cross-section ......................................................................................... 51

4 PacDrive SCL-055 Schneider Electric


1.1 Introduction

1 About this manual


1.1 Introduction

Read and understand the material contained in this manual before you work on the
PacDrive SCL-055 for the first time. Take particular note of the safety information (see
2.3 Residual risks). As described in section 2.2, only those persons who meet
the "Selection and qualification of employees" are allowed to work on the PacDrive
SCL-055.
A copy of this manual must be available for personnel who work on the PacDrive
SCL-055.
This manual is supposed to help you use the capabilities of the PacDrive SCL-055
safely and properly.
Follow the instructions within this manual to:
avoid risks
reduce repair costs and downtime of the PacDrive SCL-055
increase the service life of of the PacDrive SCL-055,
increase reliability of the PacDrive SCL-055.

1.2 Symbols, designator and display format of safety messages

Important Information
NOTE The following special messages may appear throughout this documentation or on the
equipment to warn of potential hazards or to call attention to information that clarifies
or simplifies a procedure.
The addition of this symbol to a Danger or Warning safety label indicates that an electrical
hazard exists, which will result in personal injury if the instructions are not followed.

This is the safety alert symbol. It is used to warn the user of potential personal injury
hazards. Obey all safety messages that follow this symbol to avoid possible injury or
death.

DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death
or serious injury.

WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, can result in death
or serious injury.

Schneider Electric PacDrive SCL-055 5


1 About this manual

CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in minor
or moderate injury.

NOTICE
NOTICE, used without the safety alert symbol, indicates a potentially hazardous situation
which, if not avoided, can result in equipment damage.

The following symbols and designators are used in this document:


Symbol/Character Meaning
Information Symbol: After this symbol, you will find important information
and useful tips on using the components.

Marker: After this symbol, you will find references for further information.

Prerequisite symbol: This symbol indicates a prerequisite you have to


fulfill before you start to implement an instruction.
Problem symbol: This symbol is followed by a description of the problem
and an instruction how to solve the problem.
Activity symbol: After this symbol, you will find an instruction. Follow the

instructions in sequence from top to bottom.
Result symbol: The text after this symbol contains the result of an action.

Image numbers in the text always refer to the image numbers in the
(1), (2), (3)
referenced figure.
Orientation aid: Information serving as an orientation aid regarding the
section's contents follows this symbol.

If the descriptive text contains keywords, such as parameters, they are


bold
highlighted in bold.
lBuffSelect Program code is written using a different font.

6 PacDrive SCL-055 Schneider Electric


2.1 Proper use

2 Safety information

This section contains information regarding working with the PacDrive SCL-055.
Qualified personnel working on the PacDrive SCL-055 must read and observe this
information. the PacDrive SCL-055 is conform to recognized technical safety regula
tions.

2.1 Proper use

The PacDrive SCL-055 is intended to be installed in a machine or assembled with


other components to form a machine or system.
Provide for Before installing the device, provide for appropriate protective devices in compliance
protective with local and national standards. Do not commission components without suitable
measures protective devices. After installation, commissioning, or repair, test the protective de
vices used.
Perform a risk evaluation concerning the specific use before operating the product and
take appropriate security measures.
If circumstances occur that affect the safety or cause changes to the operating be
havior of the of the PacDrive SCL-055, then immediately shut down the the PacDrive
SCL-055 and contact your Schneider Electric contact person.
Use original- Use only the accessories and mounting parts specified in the documentation and no
equipment third-party devices or components that have not been expressly approved by Schneid
only er Electric. Do not change the PacDrive SCL-055 inappropriately.

The components must not be used in the following environments:


Forbidden In hazardous (explosive) atmospheres
environments In mobile, movable or floating systems
In life support systems
In domestic appliances
underground

Installation Only use the components in accordance with the installation and operating conditions
and operating described in this documentation. The operating conditions at the installation location
conditions must be inspected and maintained in accordance with the required technical data
(performance data and ambient conditions). Commissioning is prohibited until the
usable machine or system in which the PacDrive SCL-055 is installed meets all re
quirements of EC guidelines 2006/42/EC (machinery directive).
In addition, the following standards, directives and regulations are to be observed:
EN ISO 13849-1 Safety of machinery - Safety-related parts of control systems -
Part 1: General principles for design
EN 60204-1 Safety of machinery - Electrical equipment of machines - Part 1: Gen
eral requirements
EN ISO 12100-1 - Safety of machines - Basic terms, general principles for design
- Part 1: Basic terminology, methodology
EN ISO 12100-2 - Safety of machines - Basic terms, general principles of design
- Part 2: Technical guidelines
EN 50178 - Electronic equipment for use in power installations

EN 61800-3 Adjustable speed electrical power drive systems - Part 3: EMC re


quirements and specific test methods

Schneider Electric PacDrive SCL-055 7


2 Safety information

The generally applicable local and national safety and accident prevention regu
lations.
The rules and regulations on accident prevention and environmental protection that
apply in the country where the product is used.

2.2 Qualification of Personnel


Target audi Electrical equipment must be installed, operated, serviced, and maintained only by
ence qualified personnel. No responsibility is assumed by Schneider Electric for any con
for this manual sequences arising out of the use of this material.

Qualified per A qualified person is one who has skills and knowledge related to the construction and
son operation of electrical equipment and the installation, and has received safety training
to recognize and avoid the hazards involved.
The qualified personnel must be able to detect possible hazards that may arise from
parameterization, changing parameter values and generally from mechanical, electri
cal or electronic equipment. The qualified personnel must be familiar with the stand
ards, provisions and regulations for the prevention of industrial accidents, which they
must observe when working on the drive system.

2.3 Residual risks

Health risks arising from the PacDrive SCL-055 have been reduced. However a re
sidual risk remains, since the PacDrive SCL-055 is working with electrical voltage and
electrical currents.

If activities involve residual risks, a safety message is made at the appropriate points.
This includes potential hazard(s) that may arise, their possible consequences, and
describes preventive measures to avoid the hazard(s). The following types of warnings
concerning residual risks which cannot be assigned to a specific handling. The struc
ture of a warning instruction is identical to that of a safety label.
Assembly and handling

WARNING
CRUSHING, SHEARING, CUTTING AND HITTING DURING HANDLING
Observe the general construction and safety regulations for handling and as
sembly.
Use suitable mounting and transport equipment correctly and use special tools
if necessary.
Prevent clamping and crushing by taking appropriate precautions.
Cover edges and angles to protect against cutting damage.
Wear suitable protective clothing (e.g. safety goggles, safety boots, protective
gloves) if necessary.
Failure to follow these instructions can result in death or serious injury.

8 PacDrive SCL-055 Schneider Electric


2.3 Residual risks

Hanging loads

WARNING
HAZARD FROM HANGING LOADS
Do not stand under hanging loads.
Failure to follow these instructions can result in death or serious injury.

High leakage current

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Connect devices with leakage current greater than 3.5 mA AC via a fixed con
nection with the power supply network.
In addition, implement one of the measures according to EN 50178:1997, Section
5.3.2.1.
Failure to follow these instructions will result in death or serious injury.

Touching hot surfaces

As warning against housing temperatures of the motor exceeding 70C (158F) during
nominal operation, the symbol shown here is affixed on the motor.

CAUTION
HOT SURFACES OVER 70C (158F)
Wait until the surface temperature has cooled to allow safe contact.
Wear protective gloves.
Attach protective cover or touch guard
Failure to follow these instructions can result in injury.

Schneider Electric PacDrive SCL-055 9


2 Safety information

Touching electrical parts

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Observe the general construction and safety regulations for working on high-
current electrical systems.
Operate electrical components only with a connected protective conductor.
After the installation, verify the fixed connection of the protective conductor to all
electrical devices to ensure that connection complies with the connection dia
gram.
Before enabling the device, safely cover the live components to prevent contact.
Do not touch the electrical connection points of the components when the unit is
switched on. First shut down drives because potentially fatal voltage can occur
on the motor lines in generator operation.
Provide protection against indirect contact (EN 50178:1997, Section 5.3.2).
Disconnect/plug in Plug-in connectors of the cables and plug-in terminals on the
device only when the system is disconnected from the power supply.
Isolate the unused conductors on both ends of the motor cable because AC vol
tages in the motor cable can couple to unused conductors.
Failure to follow these instructions will result in death or serious injury.

WARNING
RISK GROUPS IN THE IMMEDIATE VICINITY OF MAGNETIC AND ELECTRO
MAGNETIC FIELDS
Do not allow personnel with pacemakers or similar sensitive implants to work in
the immediate vicinity of live conductors and motor permanent magnets.
Failure to follow these instructions can result in death or serious injury.

10 PacDrive SCL-055 Schneider Electric


2.3 Residual risks

Hazardous movements
There can be different causes of hazardous movements:
Missing or incorrect homing of the drive
Wiring or cabling errors
Errors in the application program
Potential component errors
Potential error in the measured value and signal transmitter
Operation error
Protective devices breakdown

Provide for personal safety by primary equipment monitoring or measures. Do not rely
only on the internal monitoring of the drive components. Adapt the monitoring or other
arrangements and measures to the specific conditions of the installation in accordance
with a risk and error analysis carried out by the system manufacturer. For this purpose,
consider the valid safety regulations for the equipment.

DANGER
MISSING PROTECTIVE DEVICE OR INCORRECT PROTECTION
Prevent entry to a hazard area, for example with protective fencing, mesh guards,
protective coverings, or light barriers.
Dimension the protective devices properly and do not remove them.
Do not carry out any changes that can invalidate the protection device.
Before accessing the drives or entering the hazard area, safely bring the drives
to a stop.
Protect existing work stations and operating terminals against unauthorized op
eration.
Position EMERGENCY STOP switches so that they are easily accessible and
can be quickly reached.
Check the functionality of EMERGENCY STOP equipment before start-up and
during maintenance periods.
Prevent unintentional start-up by disconnecting the power connection of the drive
using the EMERGENCY STOP circuit or using an appropriate lock-out tag-out
sequence.
Check the system and installation before the initial start-up for possible glitches
in all general purposes.
Avoid operating high-frequency, remote control, and radio devices close to the
system electronics and their feed lines.
If necessary, perform a special EMC check of the system.
Failure to follow these instructions will result in death or serious injury.

Schneider Electric PacDrive SCL-055 11


2 Safety information

PELV circuits
The signal voltage and the control voltage of the devices are <30Vdc and have to be
carried out as PELV circuits. In this range the specification as PELV system, according
to IEC 60364-4-41 contains a protective measure against direct and indirect contact
with dangerous voltage through a implemented safe separation in the system/machine
of the primary and the secondary side. We recommend to design the system/machine
with a safe separation (PELV Protective-Extra-Low-Voltage).

DANGER
HAZARD OF ELECTRIC SHOCK BY INADEQUATE PROTECTIVE SEPARATION
Only connect devices, electrical components or lines to the signal voltage con
nectors of these components that feature a sufficient, protective separation from
the connected circuits in accordance with the standards (EN 50178: 1997 - Elec
tronic equipment for use in power installations - Section 5.2.14.2).
Failure to follow these instructions will result in death or serious injury.
Achieve a safe separation in the entire process of the electric circuit.
To protect from direct contact, always cover connections and contacts which guide
FELV (Functional Extra Low Voltage) voltages.
Avoid using FELV current circuits for safety reasons.
Design the cover or device connection so that it can only be removed by using a
tool.
The protection measures have to be followed on all connected devices.

12 PacDrive SCL-055 Schneider Electric


3.3 Residual risks

3 System overview

Figure 3-1: PacDrive System overview

PacDrive Controller family

The PacDrive Controller, microprocessor-based control hardware with the VxWorks


real-time operating system, centrally implements the PLC and motion functions. A
PacDrive Controller synchronizes, coordinates, and creates the motion functions for
maximum
2 drives for the PacDrive Controller C200 A2
8 drives for the PacDrive Controller C200
8 drives for the PacDrive Controller C400 A8
16 drives for the PacDrive Controller C400
99 drives for the PacDrive Controller C600
of a food and packaging machine.
Many different HMIs are used for the HMI tasks. Whether it is low-cost clear text or
IPC, it is no problem for the flexible PacDrive Controller. The PacDrive P600 Controller
is additionally equipped with a full-fledged PC. Due to its PC-based architecture, it can
perform HMI tasks with no problem in addition to the usual motion functions.
PacDrive PS-4

The power supply unit PS-4 is characterized by a compact and autonomous structure
for swapping housing installations with highly modern technology. All PacDrive SCLs
are supplied power only through one connection via PacDrive PS-4, which can be
installed quickly.
The highlights:
1 or 3 phase power supply
Integrated network filter and braking resistor
5 kW rated current / 10 kW peak current
Direct current for up to 32 SCL-055
Comprehensive diagnostic possibilities

Schneider Electric PacDrive SCL-055 13


3 System overview

PacDrive PD-8

The PacDrive PD-8 represents the combination of PS-4 and SCL-055. A distributor to
the 1 to 8 SCL-055 can be connected. If more than 8 drives are to be operated, it can
be easily expanded with one or more PD-8 distributors.
The highlights:
1 to 8 connections to the SCL-055
Easily expandable
Aseptic variants available

PacDrive SCL

The innovative SCL combines motor, power stages and the digital servo regulator for
one axis in a space-saving housing. Its compact size combines motor and power elec
tronics in the smallest space. It is excellent for decentral installations. The SCL is
available with single or multi-turn encoders and configures itself with the help of the
electronic nameplate in the SCL itself.

The highlights:
Integrated SERCOS interface
High-resolution single or multi-turn encoder
IP 65 / IP 67 degree of protection
Superior reliability
Trapezoid shape
Aseptic variants IP67 (with positive pressure)
Stainless steel housing

14 PacDrive SCL-055 Schneider Electric


4.3 Residual risks

4 Indicators and control elements


The PacDrive System supports the user by means of its diagnostic system which con
tains a powerful message logger in which additional diagnostic information is recorded
How to use the diagnostic system:
Read out diagnostic messages using the EPAS-4 Automation Toolkit or PD Di
agnostics.
If applicable, read out diagnostic messages on the control panel of the machine.
Then contact the machine manufacturer.
Detailed information on diagnostic is available in the Online Help of the EPAS-4
Automation Toolkit or the PD Diagnostics tool.

The PacDrive SCL is equipped with diagnostic LEDs for onsite diagnostic.
After removing the sercos address switch dust cap, a first diagnostic is possible directly
on the PacDrive SCL with the help of the
LEDs.
Green diagnostic LED
LED permanent off: not ready to operate, fatal system error
on

off
t in sec

LED fast flash: SCL ready to operate, SERCOS communication not in phase 4
on

off
0 0.26 0.51 1.02 2.05 t in sec

LED slow flash: boot loader is running, firmware is corrupt


on

off
1.02 2.05 t in sec

LED permanent on: SCL ready to operate,


error diagnosis available via PacDrive Controller (SERCOS phase 4)
on

off
t in sec
PD_Diagnose_LED_gruen_us.fh8

Figure 4-1: Display status of the green diagnostic LED on the SCL

Schneider Electric PacDrive SCL-055 15


4 Indicators and control elements

Red diagnostic LED


LED permanent off: no error
on

off
t in sec

LED fast flash: general error


on

off
0 0.26 0.51 1.02 2.05 t in sec

LED slow flash: SERCOS error or boot loader is corrupt


on

off
0 1.02 2.05 t in sec

LED short flash: no error, fault or interrupt procedure on the SERCOS ring
on

off
0 0.26 2.05 t in sec

LED permanent on: fatal system error


on

off
t in sec
PD_Diagnose_LED_rot_us.fh8

Figure 4-2: Display status of the red diagnostic LED on the SCL

sercos address rotary switch


With the rotary switches S1 and S2 the sercos address (0 - 99) of the device can be
set; on the switch S1 the decade and on switch S2 the unit position.

SERCOS adress: optional


sensor/actuator
tens digit connection
of the SCL
units digit standard
23
45 6
9 1
0

78
23
45 6
9 1
0

78

Figure 4-3: Rotary switch to set the sercos address

16 PacDrive SCL-055 Schneider Electric


4.1 Example of a diagnostic message

4.1 Example of a diagnostic message

The diagnostic message 121 "Braking resistor temperature too high" is displayed.
Meaning of diagnostic message:
Class 2 error
Diagnostic code 121

The meaning of the diagnostic code is explained more thoroughly in the online help
section of the EPAS-4 Automation Toolkit.
121 Braking resistor Temperature Too High
Diagnostic class (Standard): 2
Reaction: B
The braking resistor is overloaded.
The drive sizing is incorrect.
Check drive sizing.
Potential hardware error detected: The braking resistor or triggering is not oper
ating properly.
Contact the Schneider Electric customer service.

Schneider Electric PacDrive SCL-055 17


5 Transport, storage, unpacking

5 Transport, storage, unpacking


5.1 Transport
Avoid heavy shocks and/or vibrations during transport.
Check the devices for visible transport damage and inform the shipping company
immediately if necessary.
For further information on transportation. (see 7.2.1 PacDrive Controller SCL-055)

5.2 Storage
PacDrive SCL-055 has to be stored in a clean and dry room.
For further information on storage. (see 7.2.1 PacDrive Controller SCL-055)

5.3 Type plate

Figure 5-1: Nameplate of the PacDrive SCL 15010

Figure 5-2: Nameplate of the PacDrive SCL 30011

18 PacDrive SCL-055 Schneider Electric


5.3 Type plate

Label Meaning
SCL055/30011/A/00/AA/AA/ Device type, see type code
03/001
ID no. Item no.
SN Serial number
Input 1 Rated voltage and rated current of the power supply
Input 2 Rated voltage and rated current of the electronics
Type rating Degree of protection of the housing in accordance with Nema 250
and UL 50
HW Hardware version
SW Software version
IP Degree of protection
Th-Cl Insulation material class of the motor
M0 Standstill torque
Mmax Peak torque
nN Nominal speed of rotation
DOM Date of manufacture
Table 5-1: Explanation of the nameplate

NOTICE
The ready-for-use hybrid cable is already attached to the drive at the factory. (Order for each
SCL-055!)

Schneider Electric PacDrive SCL-055 19


5 Transport, storage, unpacking

5.4 Type code

SCL055 / 30 011 / A / 00 / AA / AA / 03 / 001


Flange size

Speed nN
15, 30 (x 100 min-1)

Torque M0
010 (/10 Nm) = stainless steel
011 (/10 Nm) = standard

Electronics
A = with attached motor electronic

Shaft version
0 = Standard shaft without feather key
1 = Standard shaft with feather key acording to DIN 6885
2 = Stainless stell shaft without feather key
3 = Stainless stell shaft with feather key according to DIN 6885

Casing type
0 = Self-cooling

Connection technology / motor


A = hybrid connector on the motor
B = patch connector

Connection technology / IO
0 = no I/O
A = M12-plug

Protection class shaft


A = without shaft sealing ring, without labyrinth seal / IP54
B = with shaft sealing ring, with labyrinth seal / IP65

Protection class casing


A = IP65
B = IP67 (nur fr Aseptic)

Encoder feedback
03 = SKS 36
04 = SKM 36

Option 1
0 = no option
1 = tightened drive-end
end shield

Option 2
0 = no option

Surface
1 = coated
3 = stainless stell

Figure 5-3: Type code legend of the PacDrive SCL

NOTICE
The type code is only to translate the motor identification with its codes in plain text and vice
versa. Never randomly combine the given options with each other because several options
exclude each other. The combinations that are possible depend on the technical
circumstances.

20 PacDrive SCL-055 Schneider Electric


6.1 Commissioning

6 Installation and maintenance


For warranty reasons, we recommend that you employ Schneider Electric personnel
for initial start-up. The Schneider Electric personnel
will check the equipment,
determine the optimal configuration
and instruct the operating staff.
Proceed with care during the following steps and take all precautions described
in order to help to avoid the following points:
Injuries and material damage
Incorrect installation and programming of components
the incorrect operation of components
The use of non-authorized cables or modified components

6.1 Commissioning

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Observe the general construction and safety regulations for working on high-
current electrical systems.
Operate electrical components only with a connected protective conductor.
After the installation, verify the fixed connection of the protective conductor to all
electrical devices to ensure that connection complies with the connection dia
gram.
Before enabling the device, safely cover the live components to prevent contact.
Do not touch the electrical connection points of the components when the unit is
switched on. First shut down drives because potentially fatal voltage can occur
on the motor lines in generator operation.
Provide protection against indirect contact (EN 50178:1997, Section 5.3.2).
Disconnect/plug in Plug-in connectors of the cables and plug-in terminals on the
device only when the system is disconnected from the power supply.
Isolate the unused conductors on both ends of the motor cable because AC vol
tages in the motor cable can couple to unused conductors.
Failure to follow these instructions will result in death or serious injury.
Pay attention to the ESD protection measures, to avoid damages caused by elec
trostatic discharge.

NOTICE
ELECTROSTATIC DISCHARGE
Do not touch any of the electrical connections or components.
Prevent electrostatic charges; e.g., by wearing appropriate clothing.
If necessary at all, touch circuit boards only on the edges.
Move the circuit boards as little as possible, to avoid the formation of elec
trostatic charge caused by clothing, carpet, or furnishings.
Remove existing static charge by touching a grounded, metallic surface, like
for example, a grounded housing.
Failure to follow these instructions can result in equipment damage.

Schneider Electric PacDrive SCL-055 21


6 Installation and maintenance

6.1.1 The PacDrive SCL-055 with the "positive pressure" option

Operating a PacDrive SCL-055 in the aseptic area demands high requirements for
protection against leaking fluids. The implementation of housing parts and screwed
cable glands in compliance with IP67 is not adequate in many cases because this
protection type only ensures that when immersing for minimum 30 minutes, no dam
aging quantity of water penetrates into the device.
However, in practice, various fluids with creeping properties different from water are
used. In addition, during the IP protection type test, it is not considered that there is
high pressure in the housing due to the drive heating and low pressure during cooling,
which favors the penetration of liquids.
Sealing air Continuous protection against the penetration of liquids and gases is achieved when
the housing is held under a slight overpressure with positive pressure. The com
pressed air must be dry and free of dust and oil. The air consumption is negligible since
the system is closed.
Properties Value Comment
Pressure 0.1...0.2 bar recommended
Pressure 0.4 bar Max.
Operating conditions Dust-free using suitable micro filters
Operating conditions Oil-free using appropriate oil separators
Relative humidity 20...30 %
Table 6-1: Operating conditions for the usage of positive pressure

Positive pres Positive pressure is supplied to the SCL-055 through a pneumatic hose in the hybrid
sure connec cable.
tion

plug of the SCL-055

pneumatic hose

Figure 6-1: Hybrid connection cable with pneumatic hose

The distribution terminal is impinged with positive pressure. The high pressure auto
matically reaches the housing of all SCL drives that are connected to this distribution
terminal via the open ends of the pneumatic hoses.

22 PacDrive SCL-055 Schneider Electric


6.1 Commissioning

6.1.2 Preparing commissioning

Unpacking How to unpack the device:


Remove packaging.
Dispose of the packaging material in accordance with the relevant local regula
tions.
Verifying How to check the device:
Verify that the delivery is complete.
Verify if the device is in working condition.

WARNING
DAMAGED OR MODIFIED DRIVE SYSTEMS
Do not mount or commission damaged drive systems.
Do not modify the drive systems.
Send back inoperative devices.
Failure to follow these instructions can result in death or serious injury.
Check data against type plates.
Observe requirements for the installation location.
Observe requirements for the degree of protection and the EMC rules.
Then install PacDrive SCL-055.
High leakage current

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Connect devices with leakage current greater than 3.5 mA AC via a fixed con
nection with the power supply network.
In addition, implement one of the measures according to EN 50178:1997, Section
5.3.2.1.
Failure to follow these instructions will result in death or serious injury.

6.1.3 Setting the SERCOS address


Remove the protective cap from the sercos address switch on the SCL.
Using an appropriate tool, on the back of drive, set the specified sercos address
(0-99) of the node according to the machine diagram.
Be extremely careful not to assign an address more than once in a sercos loop. Each
drive must have its own unique sercos address.
Tighten dust cap (1Nm).
6.1.4 Slaves in sercos loop

Sequence of the servcos slaves


All the slaves in the sercos loop are connected with each other via the distribution box
PacDrive PD-8. But the physical sequence of sercos slaves in the loop is the other
way around, just like the numbering of the cable glands on the PacDrive PD-8. For
example, if you have a PacDrive Controller MAx-4, one PacDrive PS-4 and four
SCL-055 motors, then the counting is as follows:
Alltogether you get six slaves.

Schneider Electric PacDrive SCL-055 23


6 Installation and maintenance

First slave -> last SCL-055 (fourth SCL-055)


Second slave -> third SCL-055
...
Fifth slave -> PacDrive PS-4
Sixth slave -> PacDrive Controller MAx-4

MAx-4 fiber optic cable transmission


copper-transmission
upgradeable
with e.g. MC-4

LWL
slip ring *)

Cu
SCL055 SCL055 SCL055
SERCOS
SERCOS SERCOS SERCOS

PS-4
SCL 1 SCL 2 SCL n
*) for information about external power via slip ring see Operation Manual PacDrive PS-4 / PD-8

Figure 6-2: Signal transmission and numbering of the sercos slaves

Changing the number of slaves in the sercos loop


If the number of sercos slaves change, you must carry out the termination as described
for the PacDrive SCL-055 according to the chapter Commissioning.

NOTICE
During commissioning, if certain circumstances result in a temporary change in the number
of slaves you do not have to remove all the cabled PacDrive SCL-055 again. Proceed as in
the example below.

Example 24 SCL-055 motors are running on your system (already fully cabled). For test pur
poses, you want to reduce the number of slaves to 10 motors.
Proceed as follows:
Remove the plug of the 11th sercos connection (this corresponds to the connec
tion (3) of the second PacDrive PD-8 box). This ensures that the physical con
nection to the subsequent sercos slaves is separated.
Terminate the 10th SCL-055 motor by inserting the jumper.
Remove the plug of the sercos connection from the SERCOS port that leads to
the subsequent PacDrive PD-8 box.
Now you have reduced the sercos loop to 10 motors.

NOTICE
It is not enough to place the jumpers on the desired terminations; no slave can be connected
on the following sercos slot.

24 PacDrive SCL-055 Schneider Electric


6.1 Commissioning

6.1.5 Cabling

You receive the PacDrive SCL with a pre-assembled, motor-sided attached cable.
Connect the cable to the PacDrive PD-8 as follows:
SERCOS in SCL055 (1) SCL055 (3) SCL055 (5) SCL055 (7) SERCOS out

Power in SCL055 (2) SCL055 (4) SCL055 (6) SCL055 (8) Power out
PD-8_Ansch.fh8

Figure 6-3: PD-8 cable glands

Remove dust cap of cable gland on the PD-8.


Push the cable of the first/next SCL-055 through the SCL-055 (1-8) opening. (For
SCL-055 (1) connection, begin in ascending order up to SCL-055 (8). Observe
sequence!)
(1) (2) (3)

(7) (8)
(4) (5) (6)
Figure 6-4: Connection of the SCL-055 to the PacDrive PD-8

(1) Power Supply


(2) Jumper for scheduling
(3) sercos connection (SCL)
(4) sercos cable
(5) Cap nut
(6) Cable gland
(7) Fuse
(8) Dummy plug

Schneider Electric PacDrive SCL-055 25


6 Installation and maintenance

Connect the power supply plug.


Insert the sercos connection plug into the sercos.
If another SCL-055 is connected, repeat steps under "Connect to electricity" until
all drives are connected as described.
If no other SCL-055 is connected, terminate the connection by inserting the two
jumpers onto the plug-in bridge.

NOTICE
The two jumpers (for termination) must be plugged in to the "closed" position at the last
PacDrive SCL-055 port via the sercos connecting plug, even if several PD-8 are used. This
closes the sercos loop, also see the chapter Technical Data.

Information on the PacDrive PD-8 connection to the PacDrive PS-4 is available in the
operating manual for "PacDrive PS-4 and PacDrive PD-8".

CAUTION
OBSERVE BENDING RADIUS FOR SCL HYBRID CABLES
For fixed installed cables, do not exceed a bending radius of 5 times the cable
diameter.
For flexible cables, do not exceed a bending radius of 12 times the cable diam
eter.
Cable damage

6.2 Configuration, homing and programming

The adjustment of the PacDrive System to its task takes place with the Automation
Toolkit EPAS-4. The system is configured and programmed in EPAS-4 according to
IEC 61131-3.

NOTICE
IMPROPER PROGRAM CHANGES
Program changes may only be carried out by trained personnel with detailed
knowledge of the system.
Program changes may only be carried out by your machine supplier or Schneider
Electric employees.
Schneider Electric is not liable for damages caused by unauthorized program
changes.
Failure to follow these instructions can result in equipment damage.

26 PacDrive SCL-055 Schneider Electric


6.3 Electromagnetic compatibility, EMC

6.3 Electromagnetic compatibility, EMC

To control and regulate the motors, the mains voltage is stored by rectification in the
DC bus of the servo amplifier. This stored power is supplied to the motor by precise
on and off switching using six semi-conductor switches. The steep increase/decrease
in voltage places considerable demands on the dielectric strength of the motor winding.
An important additional aspect to observe is the electromagnetic compatibility (EMC)
with other system components. The high rate of change of the clocked voltage gen
erates harmonics of great intensity up into the high frequency range.

NOTICE
SYSTEM FAILURE DUE TO ELECTROMAGNETIC FIELDS
During installation, select the grounding option with the lowest resistance for high
frequency operation (e.g. unpainted sub plate in control cabinet).
Provide the largest possible contact surface area (skin effect).
If necessary, remove existing layers (paint) to establish electrical contact.
Lay the grounding in a star configuration from the Central Grounding Point to the
corresponding connections.
Avoid looping the grounding to prevent unnecessary influences.
Use shielded cable only.
Ensure large shielding transitions.
Do not connect shields via the PIN contacts of connectors.
Observe the circuit suggestions.
Shorten motor cable to minimum length.
Avoid laying cable loops in the control cabinet.
In conjunction with electronic controllers, do not switch inductive loads without
suitable interference suppression.
Provide suitable interference suppression. To this end, use recovery diodes for
direct current operation and protector type-based, industry-standard quenching
circuits during alternating current activity.
Arrange the interference suppression immediately at the point of inductivity, as
otherwise even more interference may be generated by the shock of the switch
ing current on the interference suppression lines.
Avoid sources of interference instead of eliminating the effects of existing inter
ference.
Do not arrange contacts with unsuppressed inductive loads in the same room as
the PacDrive SCL-055. The same applies for connection lines that do not lead
suppressed, switched inductances and lines that run parallel to them.
Isolate the controller from such interference sources using a Faraday cage (sep
arately partitioned control cabinet).
Mains filters and motor filters may by used depending on the combination of the
servo amplifier/motor and the cable length.
Failure to follow these instructions can result in equipment damage.

Schneider Electric PacDrive SCL-055 27


6 Installation and maintenance

6.4 Maintenance, repair, cleaning

6.4.1 Repair

Quick detection and correction of faults during machine downtime help keep produc
tion downtime to a minimum.
The diagnostic messages of the PacDrive system, which can be queried using the
Automation Toolkit EPAS, allow specific and effective fault location.
In the event of a breakdown it is possible to smoothly replace defective components
to guarantee that the fault is quickly eliminated and operation can be resumed. These
jobs may only be carried out by qualified maintenance personnel.

6.4.2 Cleaning

It is not possible to test in advance, all materials of the Schneider Electric product range
that are used presently and in the future on the compatibility with the cleaning agents
available on the market.

NOTICE
DAMAGE CAUSED BY CLEANING AGENTS
Before using a cleaning agent, carry out a compatibility test in relation to the
cleaning agent and the component affected.
Do not use alkaline detergent, as polycarbonates can lose their stability if you
come into contact with them.
Do not use any chloride-containing cleaning agents as these corrode the stain
less steel and in particular the welds, and thus reduce the strength of the me
chanics.
Failure to follow these instructions can result in equipment damage.

For more information on the material properties of your component (see 7.2 Mechan
ical and electrical data).
The standard cooling method of the motor is by natural convection. Therefore, keep
the motor surfaces free from dirt.

NOTICE
IMPROPER CLEANING
Liquids can penetrate into the PacDrive SCL-055 by improper cleaning!
Use cleaning processes appropriate to the degree of protection of the PacDrive
SCL-055.
Failure to follow these instructions can result in equipment damage.

28 PacDrive SCL-055 Schneider Electric


6.5 Spare part inventory

6.5 Spare part inventory


Keep a stock of the most important components to make certain the equipment is
functioning and ready for operation at all times.
Only exchange devices with the same hardware configuration.
Indicate the following information on the spare part order:
Item name: e.g. PacDrive SCL-055:
Item no.: e.g. SCL055/30011/A/00/AA/AA/03/001
Hardware code: not specified
Software version: not specified

This information can be found on the nameplate (see 5.3 Type plate).

6.6 Device-, parts- or cable exchange

NOTICE
IMPROPER DEVICE- OR CABLE EXCHANGE
In addition to the following instructions, you must observe the machine manu
facturer's specifications when replacing devices or cables.
Failure to follow these instructions can result in equipment damage.

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Observe the general construction and safety regulations for working on high-
current electrical systems.
Operate electrical components only with a connected protective conductor.
After the installation, verify the fixed connection of the protective conductor to all
electrical devices to ensure that connection complies with the connection dia
gram.
Before enabling the device, safely cover the live components to prevent contact.
Do not touch the electrical connection points of the components when the unit is
switched on. First shut down drives because potentially fatal voltage can occur
on the motor lines in generator operation.
Provide protection against indirect contact (EN 50178:1997, Section 5.3.2).
Disconnect/plug in Plug-in connectors of the cables and plug-in terminals on the
device only when the system is disconnected from the power supply.
Isolate the unused conductors on both ends of the motor cable because AC vol
tages in the motor cable can couple to unused conductors.
Failure to follow these instructions will result in death or serious injury.

How to de-energize the system:


Set main switch to "OFF Position".
Prevent main switch from being switched back on.
After switching off, wait 15 minutes so that the DC bus can discharge.

Schneider Electric PacDrive SCL-055 29


6 Installation and maintenance

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Turn off all power supplying this equipment before working on or inside
equipment.
Failure to follow these instructions will result in death or serious injury.
Check the DC bus with a measuring instrument to make sure that it is de-energized
(< 42,4 Vdc).

Help in case of an unforeseen issue:


DC bus does not discharge completely.
Do not repair or operate component.
Contact the Schneider Electric Customer Service (see 8.1 Contact address
es).

CAUTION
HOT SURFACES OVER 70C (158F)
Wait until the surface temperature has cooled to allow safe contact.
Wear protective gloves.
Attach protective cover or touch guard
Failure to follow these instructions can result in injury.
Pay attention to the ESD protection measures, to avoid damages caused by elec
trostatic discharge.

NOTICE
ELECTROSTATIC DISCHARGE
Do not touch any of the electrical connections or components.
Prevent electrostatic charges; e.g., by wearing appropriate clothing.
If necessary at all, touch circuit boards only on the edges.
Move the circuit boards as little as possible, to avoid the formation of elec
trostatic charge caused by clothing, carpet, or furnishings.
Remove existing static charge by touching a grounded, metallic surface, like
for example, a grounded housing.
Failure to follow these instructions can result in equipment damage.

30 PacDrive SCL-055 Schneider Electric


6.6 Device-, parts- or cable exchange

6.6.1 Device replacement

How to replace the PacDrive SCL-055:


Set main switch to "OFF Position".
Prevent main switch from being switched back on.
Turn off all power supplying this equipment before working on or inside equipment.

NOTICE
MECHANICAL FORCE TO THE ENCODER SYSTEM
Prevent impacts on the motor shaft when removing and attaching couplings to
the motor shaft, as this could damage the encoder.
Use appropriate tools, such as an extractor.
Avoid mechanical damage to the coating of the motor housing.
Do not use cleaning fluid as it will damage the motor's aluminum housing.
Failure to follow these instructions can result in equipment damage.

WARNING
UNINTENTIONAL AXIS MOVEMENTS DUE TO LOSS OF REFERENCES IN CASE
OF A MOTOR REPLACEMENT
For servo axes with indirect distance measuring systems, restore the reference
to the machine coordinate system via the motor encoder every time a motor is
replaced.
Failure to follow these instructions can result in death or serious injury.

Disassembling the drive


Disassemble the earthing cable.
Dismount the drive according to the machine manufacturer's specifications.
The motor gear or coupling is released.
The screwed connections of the motor are released.
If you exchange the drive without the cable, then the following information (see
6.6.2 Cable replacement) must be considered.
Assembling the drive
If you exchange the drive without the cable, then the following information (see
6.6.2 Cable replacement) must be considered.
Assemble the drive according to the machine manufacturer's specifications.
The screwed connections of the motor are tightened.
The motor gear or coupling is connected.
Connect the earthing cable and tighten it with a 2.8 Nm torque.

NOTICE
INSUFFICIENT SHIELDING/GROUNDING
Operate the drive only with fixed cover and cable gland.
Failure to follow these instructions can result in equipment damage.

Schneider Electric PacDrive SCL-055 31


6 Installation and maintenance

6.6.2 Cable replacement

The PacDrive SCL055 is available with three different cable variants:


fixed, angular motor cable connection (standard)
fixed, straight motor cable connection (standard, stainless steel)
Plug connection, straight motor cable connection (standard, stainless steel)

NOTE Observe the following procedures during cable replacement for the different connec
tion variants and the special safety information for these activities.

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Disconnect/plug in Plug-in connectors of the cables and plug-in terminals on the
device only when the system is disconnected from the power supply.
Only connectPlug-in connectors of the cables and plug-in terminals on the device
if it is dry and clean.
If you no prefabricated cables from Schneider Electric are used, make sure that
the assignment of the new cables complies with the connection diagram of the
machine manufacturer.
Isolate the unused conductors on both ends of the motor cable because AC vol
tages in the motor cable can couple to unused conductors.
Failure to follow these instructions will result in death or serious injury.

CAUTION
STATIC CHARGE OF ELECTRONIC COMPONENTS DUE TO IMPROPER HAN
DLING
Observe the ESD regulations when opening the PacDrive SCL.
Destruction or damage to electronic components

Replace cable (fixed, angular model)


Open main switch and prevent against restart.
Turn off all power supplying this equipment before working on or inside equipment.
toothing

cap nut
screw connection

Figure 6-5: Detaching the motor cable

Loosen cap nuts and pull away backwards from the cable gland.
Press left and right tooth forming of the cable gland outwards.
Swing open rectangular cable gland at 180, until it is lying along the cable.

32 PacDrive SCL-055 Schneider Electric


6.6 Device-, parts- or cable exchange

2 Nm *) 0,6 Nm *) metal nut

sensor / actor connector


end of green
cable sheath
1,4 Nm *)
motor cover
*) stud torque washer

Figure 6-6: Open the SCL housing

Open motor cover screw.

CAUTION
IMPROPER REMOVAL OF CABLE AND PLUG! DAMAGE TO SOCKETS DUE TO
TENSILE LOAD!
Do not expose the cables to tensile load.
Press the cables through the cable gland in the direction of the motor opening,
thereby hold cable and push motor cover from the motor housing through the cable
until the green cable sleeve is visible on the inside of the motor cover.
Loosen connector lock and remove the three plugs.
Loosen inner metal nuts of the cable gland and remove cable from the cover.

NOTICE
Always replace the cable fully (cable and cable glands).Dispose off defective or worn cables
in an environmental-friendly manner. Do not work with used cables. This minimizes faults and
defects. This minimizes faults and defects.
Assemble new cable in reverse order (make sure to use the specified tightening
torques).
Replace cable (fixed, straight model)
Open main switch and prevent against restart.
Turn off all power supplying this equipment before working on or inside equipment.
Standard
cable mark
(justified)

cap nut
screw fixture

Figure 6-7: Detaching the motor cable

Loosen cap nuts and pull away backwards from the cable gland.

Schneider Electric PacDrive SCL-055 33


6 Installation and maintenance

NOTICE
Observe the cable marking. When properly assembled, the cable marking must be aligned
flushed with the cable gland so that it is just about visible. In this way, the cable is under no
strain during operation.

Standard washer
*) *) cable mark
3 Nm 0,6 Nm

1,4 Nm *)

motor cover
washer
Stainless steel
O-seal 0,6 Nm *) cable mark
cap bolt

7,5 Nm *)
O-seal
cap nut

motor cover
*) stud torque *)
1,4 Nm
Figure 6-8: Open the SCL housing

Open motor cover screw.

CAUTION
IMPROPER REMOVAL OF CABLE AND PLUG! DAMAGE TO SOCKETS DUE TO
TENSILE LOAD!
Do not expose the cables to tensile load.
Hold cable and push motor cover away from the motor housing through the cable.
Loosen connector lock and remove the three plugs.
Loosen inner metal nuts of the cable gland and remove cable from the cover.
(Aseptic variant: cable gland is screwed directly in the cover)

34 PacDrive SCL-055 Schneider Electric


6.6 Device-, parts- or cable exchange

CAUTION
LEAKING FLUID DUE TO IMPROPER INSTALLATION! MOTOR DAMAGE! IN
STALLATION OF THE SCL-055 STAINLESS STEEL:
While installing the motor cover, new O-rings must be mounted (seal set
SCL-055, 25 available (Order No. 15154410).
Before replacement, the O-rings and the motor cover seal must be greased with
suitable lubricants approved for foodstuff (e.g: Klber Lubrication, PARALIQ GTE
703).
Remove excess grease after installation.
For the stainless steel variant, use only the cable with the Item No. E-MO-105.
Dispose off defective or worn cables in an environmental-friendly manner and
never reuse.
Always replace the cable fully (cable and cable glands).
Assemble new cable in reverse order (make sure to use the specified tightening
torques, see figure "Open the SCL housing").
Perform a leak test.

NOTICE
In the SCL-055 stainless steel variant, a leak test is mandatory to ensure that the motor is
always protected from leaking liquids. The PacDrive TSP-1 (Item No. 13140022) test device
is available for the test. The exact procedure is given in the PacDrive TSP-1 operating manual.

Replace cable (jumper, standard)


Open main switch and prevent against restart.
Standard open
close

clip

Figure 6-9: Detaching the motor cable

Press strap in direction of motor housing to unlock the plug, see figure.
Install new cable in reverse order.

Schneider Electric PacDrive SCL-055 35


7 Technical data

7 Technical data
7.1 Definition of technical data

Abbre Unit Explanation


viation
I0 [Arms] Standstill current
Effective value of the motor current at standstill torque M0
IN [Arms] Rated current
Effective value of the motor current at rated torque MN
Imax [Arms] Peak current
Effective value of the motor current at peak torque Mmax
JM [kgcm2] Rotor moment of inertia
The rotor inertia refers to a motor without brake.
kT [Nm/Arms] Torque constant
Quotient from the standstill torque M0 and standstill current I0 (at 120C winding temperature).
m [kg] Mass
Motor mass without brake and without fan
M0 [Nm] Standstill torque; Continuous torque (100% ED) at 5 min-1 by an ambient temperature of 40 C and
a winding temperature of 120 C..
MN [Nm] Rated torque; Continuous torque (100% ED) by nN due to the speed-dependent losses less than
M0, by an ambient temperature of 40 C and a winding temperature of 120 C..
Mmax [Nm] Peak torque
The maximum torque that the servo motor can briefly deliver to the output shaft.
nN [min-1] Rated motor speed
nmax [min ] -1
Mechanical limit velocity
PN [kW] Mechanical rated power (power delivered to the shaft)
At the rated motor speed and load with the rated torque
RU-V, 20 [] Winding resistance
Resistance between two phases at a winding temperature of 20 C.
LU-V [mH] Winding inductance between two phases
kE [Vrms/kmin ] -1
Voltage constant; Induced voltage between two phases at 1000 min-1
V [m/s2] Maximum vibration (all directions)
S [m/s2] Maximum shock (all directions)
TTK [C] Response limit temperature sensor
tth [min] Thermal time constant
p Number of pole pairs
Table 7-1: Physical sizes with units and explanations

36 PacDrive SCL-055 Schneider Electric


7.2 Mechanical and electrical data

7.2 Mechanical and electrical data

7.2.1 PacDrive Controller SCL-055

Designation Value
Power supply
- Rated connecting voltage/ current DC 325 V / 1 A
- DC circuit capacity 33 F
Electronics supply
- Control voltage / control current DC 24 V / 0.3 A
- Input capacity 40 F
Touch probe inputs (Sensor/Actuator) Number: 2 (IEC61131-2)
Range UIN 0 Voltage: DC 0 ... 5 V
Range UIN 1 Voltage: DC 15 ... 35 V
Input current: IIN = 5 mA at UIN = 24 V
polarized: yes
Input filter: 100 s
Digital outputs (Sensor/Actuator) Number: 1 (IEC61131-2)
Output voltage:
low 0 to 5 V, high > 21 V
ILnom.: 250 mA
Start-up current: Iemax < 0.7 A for 1 s
Idle current: 0.3 A
short-circuit protection: yes
Weight see techn. Data SCL 055 - Motor data
Ventilation Natural convection
Ambient conditions
- Degree of protection IP65, IP67
- Ambient temp. during operation +5 ... +40 C
- during storage and transport -25 C ... +70 C, T/t = max. 30 K/h
- Overvoltage category K II, (DIN VDE 0110)
- Radio interference level Class A EN 55011 / EN 61800 - 3
- Insulation material class F
Approval CE, UL (available as of KW42), cUL
Table 7-2: Technical Data - SCL055 - Controller

NOTICE
The PacDrive SCL made of stainless steel can only be operated with Firmware versions
V00.16.33 or higher.

Schneider Electric PacDrive SCL-055 37


7 Technical data

7.2.2 Technical Data - PacDrive SCL-055 30 011 and SCL-055 15 010

Designation Abbreviation SCL-055 30 011 SCL-055 15 010


[unit] Standard Stainless steel
Standstill torque M0 [Nm] 1.09 0.85
Rated motor speed nN [min ] -1
3000 1500
Peak torque (20 C) Mmax [Nm] 3.6 4.0
Physical Data
Max. mechanical limit velocity nlimit [rad/s] 420 420
Rotor moment of inertia JM [kgcm2] 0.11 0.146
Weight (incl. electronics):
1)
m [kg] 3.2 4.3
Thermal data
Response limit thermal contact TTK [C] 130 130
Thermal time constant tth [min] 44 44
Electrical data
Number of poles PZ 6 6
Motor coils circuit Y Y
Torque constant (20 C) KT20 [Nm/A] 0.89 1.21
Torque constant (120 C) KT120 [Nm/A] 0.81 1.1
Winding resistance (20 C) R20 [Ohm] 19.9 37.7
Winding inductivity L [mH] 45.5 87.3
EMF at 1000 [min-1] EMF [V] 50 78
Standstill current (Cu = 120 C) I0 [A] 1.35 0.76
Rated current IN 1.31 0.7
Peak current (Cu = 120 C) Imax [A] 5.0 3.8
1)
Weight without cable (cable weight per meter = 0.18 kg)

7.2.3 Encoder

SinCos-Encoder

Parameter SKS/SKM 36 Unit


Number of sine-cosine periods per revolution 128
Moment of inertia of the rotor 4.5 gcm2
Measuring step according to the arc tangent with 12bit res 2.5 Arcsecond
olution
Number of steps per revolution "SRS Singleturn" 4096
Number of steps per revolution "SRM Multiturn" 16.777.216 = 4096 x 4096
Resistance to shocks in mounted condition according to DIN 100/6 g/ms
IEC 68 Part 2-27
Resistance to vibration in mounted condition according to 50/10 ... 2000 g/Hz
DIN IEC 68 Part 2-6
Table 7-3: Technical data of the SinCos encoder (SKS/SKM)

38 PacDrive SCL-055 Schneider Electric


7.2 Mechanical and electrical data

7.2.4 Motor shaft and bearings

Design of the shaft end


Smooth With a non-positive connection, torque transmission must be achieved only by surface
shaft end pressure. That ensures safe power transmission without backlash.
(standard)

Manufacturer Designation
VMA Compensating coupling with clamping-hub ASK
Connection-, measuring and drive technic Type BB
Fliederweg 2
D-63814 Mainaschaff
Tel.: (06021) 79020
Fax: (06021) 790220
E-Mail: info@vma-nc.de
Table 7-4: Manufacturer's non-positive connections

Permissible shaft load


In case of technical correct use, the life of drives is limited by the bearing life. The
customer may not replace the bearing, as the measuring systems integrated in the
drive must then be reinitialized.

Figure 7-1: Definition of shaft load

Speed [min-1] 1000 1500 2000 3000


Radial force FRadial [N] 330 330 310 270
Table 7-5: Permitted radial force Fradial [N] depends on the drive speed of SCL-055

Radial and axial limit loads must not be simultaneous.

CAUTION
MECHANICAL FORCE!
POSSIBLE HAZARD TO THE MOTOR!
Do not exceed a maximum permissible pressing force of 165 N on the shaft end.

Schneider Electric PacDrive SCL-055 39


7 Technical data

Basis for calculation:


The permissible axial force Faxial [N] is calculated according to:
Faxial = 0.2 x Fradial
Nominal bearing life L10h = 20,000 h for a shaft without feather key nut (for operating
hours at a 10% failure probability)
Ambient temperature = 40 C (approx. 100 C storage temperature)
Peak torque = 10 % ED
Nominal torque = 100 % ED

40 PacDrive SCL-055 Schneider Electric


7.3 Mounting arrangement and degree of protection

7.3 Mounting arrangement and degree of protection

The drive degree of protection depends on the mounting arrangement. The mounting
flange for all drive types is designed in such a way that the installation type is possible
according to the types of construction IM B14, IM V18 and IM V19. By the DIN IEC
34-7 the drives can be mounted to the machine according to the following listing types.:

IM B14 IM V18 IM V19


Figure 7-2: Drive installations

CAUTION
PENETRATING LIQUIDS DUE TO INADMISSIBLE ASSEMBLY POSITION
When using the PacDrive SCL in the setup IM V19 you must use a drive with
radial shaft seal + labyrinth seal (stainless steel).
Failure to follow these instructions can result in equipment damage.

Motor part Degree of protection (ac Mounting position (conforming to DIN 42 950)
cording to EN 60529)
Shaft IP 50 IM V19
IP 54 IM B14, IM V18
IP 65 IM V19 (shaft sealing ring)
IP 67 -
Surface/connections IP 65 IM B14, IM V18, IM V19
Table 7-6: Degree of protection of the SCL servo motor

Schneider Electric PacDrive SCL-055 41


7 Technical data

7.4 Torque/speed characteristic curves

The torque-speed characteristic curve represents the following characteristics:


The permissible permanent torque (operating type S 1)
The peak torque with mains voltage = 3 x 230 Vac

4,0

3,6
Mmax230V 3 AC
3,2

2,8

2,4
Torque [Nm]

2,0

1,6
M0 MN(Operating mode S1) MN
1,2

0,8

0,4

0,0
0 500 1000 1500 2000 2500 3000
Speed [min-1]

Figure 7-3: Example of a torque-speed characteristic curve

The characteristic curves refer to an ambient temperature of 40C and a maximum


winding temperature of 120C.

42 PacDrive SCL-055 Schneider Electric


7.4 Torque/speed characteristic curves

4,0

3,6

3,2

2,8

2,4
Torque [Nm]

2,0

1,6

1,2

0,8

0,4

0,0
0 500 1000 1500 2000 2500 3000
Speed [min-1]

Figure 7-4: Torque/speed characteristic curve SCL 055/30011 Standard

4,0

3,6

3,2

2,8

2,4
Torque [Nm]

2,0

1,6

1,2

0,8

0,4

0,0
0 250 500 750 1000 1250 1500
Speed [min-1]

Figure 7-5: Torque - speed characteristic line SCL 055/15010, stainless steel design

Schneider Electric PacDrive SCL-055 43


7 Technical data

7.5 Electrical connections

plug of the PD-8

SERCOS
adress:
optional
tens digit sensor/actuator connection
units digit of the SCL Standard
23
45 6
9 1
0

78
23
45 6
9 1
0

78

Figure 7-6: Connection overview - PacDrive SCL

No sensor/actuator connection is available for the stainless steel variant.


No sensor/actuator connection is available for the stainless steel variant.

Pin Designation Meaning Range


5
4 1

1 OUT 0 Standard output 0 *)


DC 20 ... 30V / 0.1A
3 2 2 IN 1 Standard input 1 touch DC 20 ... 30 V
test of input 1**)
3 0V GND Ground
4 IN 0 Standard input 0 touch DC 20 ... 30 V
test of input 0**)
5 PE Ground conductor/
Shield
*) can also be used for the power supply of external sensors
**) from Firmware version V00.20.00
Table 7-7: Connection socket - Sensor/actuator on SCL
Power Supply

4 3
Pin Designation Meaning Range
1 PE Protective ground con
ductor
2 1

2 PE Shield
3 DC- DC circuit - DC 270 ... 370 V
4 DC + DC circuit + DC 270 ... 370 V
Table 7-8: Power supply connection plug

44 PacDrive SCL-055 Schneider Electric


7.6 Dimensions

sercos connection

8 7 6 5
Pin Designation Meaning Range
1 24 V Control voltage 24 V -15 % ... +25 %
4 3 2 1
2 sercos Out + sercos Transmit +
3 Shield Shield sercos Out
4 sercos In + sercos Receive +
5 0V Control voltage 0 V
6 sercos Out - sercos Transmit -
7 Shield Shield sercos In
8 sercos In - sercos Receive -
Table 7-9: sercos connection

7.6 Dimensions

Figure 7-7: PacDrive SCL-055 dimensions in mm (the conversion table is in the appendix) /
Standard design, angular cable

Figure 7-8: PacDrive SCL-055 dimensions in mm (the conversion table is in the appendix) /
Standard design, straight cable

Schneider Electric PacDrive SCL-055 45


7 Technical data

Figure 7-9: PacDrive SCL-055 dimensions in mm (the conversion table is in the appendix) /
Standard design, plug connector

 




M


7.


[
 

5
  r r
0[PP

[ 


r

Figure 7-10: PacDrive SCL-055 dimensions in mm (the conversion table is in the appendix) /
Stainless stell design, straight cable, Standard

  r

r





M

 
7.


[

5
  
0[PP
 
[
r

Figure 7-11: PacDrive SCL-055 dimensions in mm (the conversion table is in the appendix) /
Stainless steel design, straight cable, option 1 - reinforced drive end shield

46 PacDrive SCL-055 Schneider Electric


8.1 Contact addresses

8 Appendix
8.1 Contact addresses

Schneider Electric Automation GmbH


Schneiderplatz 1
97828 Marktheidenfeld, Germany
Phone: +49 (0) 9391 / 606 - 0
Fax: +49 (0) 9391 / 606 - 4000
Email: info-marktheidenfeld@schneider-electric.com
Internet: www.schneider-electric.com

Machine Solution Service


Schneiderplatz 1
97828 Marktheidenfeld, Germany
Phone: +49 (0) 9391 / 606 - 3265
Fax: +49 (0) 9391 / 606 - 3340
Email: automation.support.de@schneider-electric.com
Internet: www.schneider-electric.com

See the homepage for additional contact addresses:


www.schneider-electric.com

8.2 Product training courses

Schneider Electric offers a number of product training courses.


Our training instructors will help you take advantage of the extensive possibilities of
fered by the system.

See the homepage (www.schneider-electric.com) for further information and our cur
rent seminar schedule.

Schneider Electric PacDrive SCL-055 47


8 Appendix

8.3 EC declaration of conformity

EC DECLARATION OF CONFORMITY
Document number / Month.Year: HRB7837300_00 / 03.2013
- Original -

We: Schneider Electric Industries SA


35, rue Joseph Monier
92506 Rueil Malmaison
France

hereby declare that the product


Trademark: Schneider Electric
Product, Type, Function: SCL integrated servomodule
Models: VIL
Serial number: YYZZXXXXXX (YY: Year, 22=2012, 23=2013; ZZ: Supplier Code;
XXXXXX:Continuous number)
with the references
Reference Description
VIL2zxxxzzxzzxx SERVO SCL055, 3KRPM
VIL3zxxxzzxzzxx SERVO SCL055, 1,5KRPM
z are letters, x are numbers for different variations

are in conformity with the requirements of the following directives and conformity was checked in accordance with the
following standards:
Directive Harmonized Standard
DIRECTIVE 2004/108/EC OF THE EUROPEAN EN 61800-3:2004 + A1:2012
PARLIAMENT AND OF THE COUNCIL (EMC) Adjustable speed electrical power drive systems - Part 3:
of 15 December 2004 on the approximation of the EMC requirements and specific test methods (IEC 61800-
laws of the Member States relating to electromagnetic 3:2004 + A1:2011)
compatibility and repealing Directive 89/336/EEC
DIRECTIVE 2006/95/EC OF THE EUROPEAN EN 61800-5-1:2007
PARLIAMENT AND OF THE COUNCIL Adjustable speed electrical power drive systems - Part 5-
of 12 December 2006 on the harmonisation of the laws 1: Safety requirements - Electrical, thermal and energy
of Member States relating to electrical equipment (IEC 61800-5-1:2007)
designed for use within certain voltage limits

It is important that the component is subject to correct installation, maintenance and use conforming to its intended
purpose, to the applicable regulations and standards, to the suppliers instructions, user manual and to the accepted
rules of the art.

First year of affixing CE Marking: 2008

France -Rueil Malmaison, March 2013

i.A. Peter Spitzfaden


Certification Manager

48 PacDrive SCL-055 Schneider Electric


8.4 Changes

8.4 Changes

The latest product documentation, application notes and the change service are al
ways available on the Schneider Electric Homepage.

07/2003
New edition of the operating manual

12/2004
Addition of the chapter "sercos slaves"
Addition of the chapter "Aseptic variants"
Various error eliminations and additions
Layout change

01/2007
Addition of stainless steel variant

03/2008
Upgrading documentation to include SCL type 30011
Update of technical type plates and type keys
Operating manual limited to SCL Standard and stainless steel variants
Revising the chapters 3 and 6
Update of the Characteristic curves
Revising the Dimensional drawings

06/2013
Complete revision of the operating instructions

Schneider Electric PacDrive SCL-055 49


8 Appendix

8.5 Units and conversion tables

8.5.1 Length

in ft yd m cm mm
in - / 12 / 36 * 0.0254 * 2.54 * 25.4
ft * 12 - /3 * 0.30479 * 30.479 * 304.79
yd * 36 *3 - * 0.9144 * 91.44 * 914.4
m / 0.0254 / 0.30479 / 0.9144 - *100 * 1000
cm / 2.54 / 30.479 / 91.44 / 100 - * 10
mm / 25.4 / 304.79 / 914.4 / 1000 / 10 -

8.5.2 Mass

lb oz slug 0.22 kg g
lb - * 16 * 0.03108095 * 0.4535924 * 453.5924
oz / 16 - * 1.942559*10 -3
* 0.02834952 * 28.34952
slug / 0.03108095 / 1.942559*10-3 - * 14.5939 * 14593.9
0.22 kg / 0.45359237 / 0.02834952 / 14.5939 - * 1000
g / 453.59237 / 28.34952 / 14593.9 / 1000 -

8.5.3 Force

lb oz p dyne N
lb - * 16 * 453.55358 * 444822.2 * 4.448222
oz / 16 - * 28.349524 * 27801 * 0.27801
p / 453.55358 / 28.349524 - * 980.7 * 9.807*10-3
dyne / 444822.2 / 27801 / 980.7 - / 100*103
N / 4.448222 / 0.27801 / 9.807*10-3 * 100*103 -

8.5.4 Power

HP W
HP - * 746
W / 746 -

8.5.5 Rotation

min-1(rpm) rad/s deg./s


min (rpm)
-1
- * / 30 *6
rad/s * 30 / - * 57.295
deg./s /6 / 57.295 -

50 PacDrive SCL-055 Schneider Electric


8.5 Units and conversion tables

8.5.6 Torque

lbin lbft ozin Nm kpm kpcm dynecm


lbin - / 12 * 16 * 0.112985 * 0.011521 * 1.1521 * 1.129*106
lbft * 12 - * 192 * 1.355822 * 0.138255 * 13.8255 * 13.558*106
ozin / 16 / 192 - * 7.0616*10 -3
* 720.07*10 -6
* 72.007*10 -3
* 70615.5
Nm / 0.112985 / 1.355822 / 7.0616*10-3 - * 0.101972 * 10.1972 * 10*106
kpm / 0.011521 / 0.138255 / 720.07*10 -6
/ 0.101972 - * 100 * 98.066*106
kpcm / 1.1521 / 13.8255 / 72.007*10-3 / 10.1972 / 100 - * 0.9806*106
dynecm / 1.129*10 6
/ 13.558*10 6
/ 70615.5 / 10*10 6
/ 98.066*10 6
/ 0.9806*10 6
-

8.5.7 Moment of inertia

lbin2 lbft2 kgm2 kgcm2 kgcm2s2 ozin2


lbin2 - / 144 / 3417.16 / 0.341716 / 335.109 * 16
lbft 2
* 144 - /3 *0.30479 *30.479 *304.79
kgm2 * 3417.16 / 0.04214 - *0.9144 *91.44 *914.4
kgcm 2
* 0.341716 / 421.4 /0.9144 - *100 *1000
kgcm2s2 * 335.109 / 0.429711 /91.44 /100 - *10
ozin 2
/ 16 / 2304 / 54674 / 5.46 / 5361.74 -

8.5.8 Temperature

F max K
F - (F - 32) * 5/9 (F - 32) * 5/9 + 273.15
max C * 9/5 + 32 - C + 273.15
K (K - 273.15) * 9/5 + 32 K - 273.15 -

8.5.9 Conductor cross-section

AWG 1 2 3 4 5 6 7 8 9 10 11 12 13
mm 2
42.4 33.6 26.7 21.2 16.8 13.3 10.5 8.4 6.6 5.3 4.2 3.3 2.6

AWG 14 15 16 17 18 19 20 21 22 23 24 25 26
mm 2
2.1 1.7 1.3 1.0 0.82 0.65 0.52 0.41 0.33 0.26 0.20 0.16 0.13

Schneider Electric PacDrive SCL-055 51


Index

Index
S
Seminars 47
C Service addresses 47
Cleaning 28 Storage 18
Cleaning agents 28 Symbols 6
Configuration 26
Contact addresses 47
T
Training courses 47
D Type code 20
Definitions 36
Diagnostic message 17
Diagnostics 15 U
domestic appliances 7
underground 7

E
EMC rules 27

F
floating systems 7
flying systems 7

H
hazardous, explosive atmospheres 7
Hazards 8
Homepage 47

L
life support systems 7

M
mobile systems 7

P
Physical sizes 36
portable systems 7

Q
Qualification of Personnel 8
Qualified person 8

R
Residual risks 8

52 PacDrive SCL-055 Schneider Electric

Das könnte Ihnen auch gefallen