July - September 2005

Issued by : EBG - Electrical Systems & Equipment, LARSEN & TOUBRO LIMITED, Powai Works, Mumbai 400 072

Prospect / Retrospect

L&T Switchboards Seismically Qualified


In critical applications, like Nuclear Power Plants, operation or safety in the event of a design-basis
Seismic Qualification of equipment is essential from accident and whose failure would not result in the
safety point of view. In order to define acceptance release of a significant amount of radioactivity. Loads
criteria for various equipment depending on their connected to this system can tolerate prolonged
application, they are classified as :- power supply interruptions.

Class I : Where failure of equipment might cause or Larsen & Toubro Limited, has successfully tested
increase the severity of a design basis accident or its complete range of LV Switchboards for Seismic
result in an uncontrolled release of substantial Qualification for Class-II & Class-III. L&T is the only
LV switchboard manufacturer in India to have its
amount of radioactivity.
complete range Seismically Qualified.
Class II : Structures and components which are The range covers :
important to reactor operation, but not essential for
& Power Control Centre
safe shutdown and isolation of the reactor, and
& Motor Control Centre
whose failure could not result in the release of a
& AC Distribution Boards
substantial amount of radioactivity.
& DC Distribution Boards
Class III : Structures not directly related to reactor The test procedure was based on IEEE 344-1987
operation or safety in the event of a design-basis Recommended Practice for Seismic Qualification
accident and whose failure would not result in the of Class-1E equipment for Nuclear Power Generating
release of a significant amount of radioactivity. Loads Stations.
connected to class III bus can tolerate short
interruptions in the power supply. This issue of L&T Current Trends elaborates on the
theory of earthquakes and the test essentials for
Class IV : Structures not directly related to reactor Seismic Qualification.

Visit us at www.LNTEBG.com
FEATURE

Seismic Qualification of Electrical Equipment


- Mr. Tushar N. Shah
Switchgear Design & Development Centre

Introduction: of Seismic
waves through
Earthquakes are perhaps the rocks cause
most devastating and destructive shaking that we
forces in nature. Because of feel as
mans present inability to predict earthquakes.
and control them due to the ever-
increasing settlement of large The majority of
population in areas of high earthquakes
seismic activity, the human occur on the fault
exposure to earthquakes is lines which
increasing. This calls for demarcate the
protection of men and machinery. tectonic plates
Earthquake
The problem is more severe from the earths
because of the development and crust. Tension accumulates when
epicenter . The depth of the
application of highly sensitive the plates slowly shift away from
hypocenter varies greatly: from a
technology in critical facilities such each other. The sudden release
few kilometers to up to 100 km.
as nuclear power plants, high tech of distorting energy which has
industries, bridges, dams, thus accumulated inside the
A list of some of the significant
buildings etc. Thus a need for earths crust, or in the underlying
earthquakes in India and their
building reliability in equipment and layer called the mantle, provokes
location:
structures against vibration a local agitation. Some of this
hazards posed by these energy is then transformed into
earthquakes has gained prime seismic waves at
importance. the surface of the Date Epicenter Magnitude
ground. It is the 2001 Jan 26 Bhuj, Gujarat 7.9
1999 March 29 Chamoli, Uttar Pradesh 6.8
Seismic qualification is necessary creation of a fault
1997 May 22 Jabalpur, MP 6.0
for all those equipment and line, or more 1993 Sept. 30 Latur-Osmanabad, Maharashtra 6.3
structures which are designed to frequently the slide 1991 Oct. 20 Uttarkashi 6.6
remain functional during/after the along an existing 1988 Aug 21 Bihar-Nepal Border 6.4
occurrence of an earthquake. fault line, which 1975 Jan 19 Kinnaur, Himachal Pradesh 6.2
constitutes the 1958 July 21 Anjar, Gujarat 7.0
Earthquakes: generating mecha- 1957 Dec 10 Koyna, Maharashtra 6.5
1950 Aug 15 AP-China Border 8.5
nism of an earth-
1943 Oct 23 Assam 7.2
Earthquakes are powerful quake. The place 1941 June 26 Andaman Islands 8.1
manifestations of sudden where it occurs is 1934 Jan 15 Bihar Nepal Border 8.3
releases of strain energy called the seismic 1930 July 2 Dhubri, Assam 7.1
accumulated during extensive time focus or the 1918 July 8 Assam 7.6
intervals. They radiate Seismic hypocenter . The 1905 April 4 Kangra, Himachal Pradesh 8.0
projection from this 1897 June 12 Shillong Plateau 8.7
waves of various types which
1885 May 30 Sopore, J&K 7.0
propagate in all directions through point to the ground 1869 Jan 10 Near Cachar, Assam 7.5
the Earths interior. The passage is called the 1819 June 16 Kutch, Gujarat 8.0
Mercalli sub-assemblies and components
(intensity) 1 2 3 4 5 6 7 8 9 10-11-12 as per National / International
standards.
Richter
(magnitude) 0-2 1-2 2-3 3-4 4-5 5-6 5-7 6-8 7-9 >8 The salient features of the system
The correlation between the Mercalli and Richter scales is completely indicative because they are as follows:
depend on soil type, distance from the seismic focus (from 5 to 100 km) and earthquake
duration. Table Size 3.0 x 3.0 m
Mode of Axis TRI AXIAL
Intensity & Magnitude: expresses the intensity of an
earthquake. It is a subjective Degrees of Six (3 translational
The Richter scale and the means to describe severity of the Freedom + 3 rotational motion)
modified Mercalli scale are the shock felt at a location. Pay Load 10 T
two common ways to express the
severity of an earthquake. Seismic Test System: Max. Height 10 m
of specimen
Richter scale indicates the Earthquake Engineering and AXIS X/Y Z
magnitude of an earthquake, Vibration Research Center of -Displacement (150mm) (100mm)
which is measured by the CPRI, Bangalore houses the -Velocity ( 1000mm/s )
amplitude of the seismic waves state-of-the-art tri-axial shaker -Acceleration ( 1 g )
and is related to the amount of system with six degrees of
energy released. freedom, capable of performing a Frequency Range 0.1 to 50 Hz
diverse range of seismic Yawing moment 0 ton.m
The modified Mercalli scale, qualification tests on equipment,
Overturning moment 40 ton.m
Intensity Modified Mercalli scale Actively controlled in 6 degrees of
freedom
1 Terror not felt.
2 Tremor felt by those resting or situated on top floors. The system consists of 4 vertical
3 Hanging objects move. Slight vibrations actuators and 4 horizontal actuators.
4 Vibrations similar to those provoked by a heavy lorry passing are felt.Window Waveforms of Response
panes and crockery rattle. Stationary vehicles sway.
Spectra of Seismic Tests:
5 Tremor felt outside buildings. Those sleeping are woken up. Small objects fall
down. Pictures are tipped sideways. Operating Basis Earthquake
6 Tremor felt by everyone. Furniture is moved. Damage: broken glass, objects (OBE) OBE level of earthquake
thrown from shelves, slight cracks appear in plastering. is expected to occur at the site
once in 100 years.
7 Tremor felt in moving vehicles. Those standing fall off balance, church bells
ring. Damage: chimneys and other external architecture break away, plaster
Safe Shutdown Earthquake
falls down, broken furniture, extended cracks in plastering and masonry,
some houses in brick collapse. (SSE) SSE level of earthquake
is expected to occur at the site
8 Drivers in moving vehicles experience difficulties. Branches fall from trees. once in 10000 years.
Fissures appear in waterlogged ground. Destruction: water towers, monuments,
brick houses. Slight to substantial damage: brick buildings, prefabricated Required Response Spectrum
houses, irrigation works, and causeways.
(RRS) The response spectrum
9 Sand craters in sandy and waterlogged ground in urban areas. Landslides. issued by the user as a part of
Fissuring in ground. Destruction: non-reinforced brick masonry. Slight to the specifications. The RRS
substantial damage: insufficiently reinforced concrete structures, underground constitutes a requirement to be
piping. met.
10 Landslides and major ground destruction. Destruction: bridges, tunnels, certain
reinforced concrete structures. Slight to substantial damage: the majority of Test Response Spectrum (TRS)
buildings, dams, railway lines. The response spectrum that is
11 Permanent ground deformation. developed from the actual time
history of the motion of the shake
12 Almost total destruction. table.
Generation of Waveforms: l Resonance Search Test: fixing components.
These are generally not a & No undue chattering of
& RRS is extrapolated into a part of the seismic contacts should be observed
vector covering the whole qualification requirements. for a duration longer than
frequency range of interests, These tests are carried out 10ms.
with a spectral resolution of at input levels well below the & All the doors should remain
sample rate/Fast Fourier required seismic closed during testing.
Transform (FFT) block size. qualification vibration level
& Random time history is i.e. 0.2g. The resonance Conclusion:
generated for specified search is carried out up to
duration. 50Hz. (Sweep rate: 1 The high degree of continuity of
& FFT filter given by RRS is octave per min.) service required for electrical
applied. l 5nos. of Operating Basis distribution and control/monitoring
& TRS of filtered time history is Earthquake (OBE) Test. equipment demands that all types
computed. This is done by l 1no. of Safe Shutdown of environmental restrictions
generating a 2nd order low pass Earthquake (SSE) Test. (mechanical, electromagnetic,
filter. The process is repeated Both OBE and SSE test is climatic) are taken into account.
for all frequencies between the conducted with the equipment Seismic stresses, which are
lowest to highest frequency. in energized condition. particularly destructive, are also
& Low frequency end of final Duration for the each OBE & included and they must be
acceleration time history is SSE test is 30 sec. During the specified at the design stage of
modified and tapers are applied test, the condition of the relays/ the equipment.
to ensure the equivalent products is monitored.
velocity and displacement & There should not be mal- Proving that the equipment
histories start and finish at operation of products mounted remains operational during or after
zero. in the switchboard. the earthquake is very difficult and
& Overall acceleration amplitude & No permanent deformations or generally requires numerical
is adjusted to make sure that cracks/fractures should be analysis to be combined with tests
the TRS exceeds RRS over developed in any of the on the operational elements. As
the whole frequency range of components/structures that will for quality or electromagnetic
interest. affect satisfactory operation of compatibility, seismic withstand
the equipment. must be mastered at the design
Seismic Qualifications: & All welding, bolting should be stage; if this is neglected then it
intact. There should not be is often difficult and more
& Equipment is tested for the cracks in welds or loosening expensive to correct problems at
following tests: of bolts/hardware used for a later stage.

Typical TRS Plot for OBE Test Typical TRS Plot for SSE Test

For further details on this subject, please contact:


EBG - Electrical Systems & Equipment, Larsen & Toubro Limited, Saki-Vihar Road, P.O. Box 8901, Powai, Mumbai 400 072
Fax: 022-5505 1024 * E-mail: kotnisnd@Intebg.com

Printed by Printania Offset Pvt. Ltd.,D 20/21, Shalimar Industrial Estate, Matunga (East), Mumbai 400 019. Tel.: 2407 7996/
8866/4540 Fax : 2402 4703 Email: pds6@rediffmail.com The views expressed in this magazine are not necessarily those of the
management of Larsen & Toubro Limited. The contents of this magazine should not be reproduced without the written permission
ABCI
of the Editor. Not for sale-only for circulation among the customers. Editorial Coordinators : R. S. Mahajan, Neelam D. Kotnis,
Member EBG-ESE, Powai .

Das könnte Ihnen auch gefallen