Sie sind auf Seite 1von 340

High Voltage Induction Motors

for Chemical, Oil and Gas

1 COG catalogue_start_excl_DIP.indd 1 25.3.2008 9:33:54


Improved performance with ABB high voltage induction motors
ABB has been manufacturing high quality electric motors and generators for more than 100 years. Motors
for hazardous areas represent one of its special areas of focus. Working together with major companies
in the oil and gas, petrochemical and chemical industries, ABB has developed a comprehensive range of
products that offer safety, reliability and energy efciency.
The regulatory situation in which ABBs customers operate is complex and constantly changing, with the
introduction of new European and US standards among the latest developments. ABB ensures that its
products not only comply with the relevant regulations but in many cases surpass them.

This catalogue features induction motors for use in hazardous locations in the chemical, oil and gas
industries. Standard induction motors, which are also widely used in chemical, oil and gas industries,
are presented in a separate catalogue: ABB High Voltage Induction Motors, Technical catalogue (Code
9AKK103508)

1 COG catalogue_start_excl_DIP.indd 2 25.3.2008 9:33:56


Motors for Chemical, Oil and Gas
High voltage induction motors, sizes 315 to 710, from 100 to 4500 kW

Contents Page

1 General information 4 1

2 High voltage technical specication 14 2

3 Non-sparking motors Ex nA 19 3

4 Increased safety motors Ex e 111 4

5 Pressurized motors Ex p 113 5

6 Flameproof motors Ex d - Ex de 177 6


7 Class I Division 2 / Zone 2 motors 273
7

ABB reserves the right to change the


design, technical specication and
dimensions without prior notice.

ABB/ BU Machines / HV Motors for COG EN 02-2008 3

1 COG catalogue_start_excl_DIP.indd 3 25.3.2008 9:33:57


The following factors have helped to make ABB motors Lifecycle support - ABB motors and generators are
and generators the preferred choice of professionals covered by an extensive global technical and service
throughout the supply chain - from end users to original support network. From spare parts to maintenance
equipment manufacturers - in all parts of the world: contracts and motor diagnostics, ABB can provide
on-site service and maintenance throughout the
High efciency - ABB motors and generators feature
products lifetime. Support is always available!
high efciency, providing signicant savings in power
and operating expenses, and helping to reduce carbon Safety ABB puts safety rst. ABBs non-sparking
dioxide emissions. motors, for example, have passed the very demanding
gas environment tests required by the latest standards.
Reliability - independent research and internal studies
This veries that these motors really are non-sparking
by major oil and gas companies have conrmed that
in hazardous environments.
ABB motors help to maximize uptime. In a major
renery, even a small increase in average operating Durability - ABB has an unrivalled track record in
1 time can have a signicant impact on throughput.
Maintainability ABBs motors are designed for
supplying durable and dependable motors for all kinds
of operating environments, from the extreme cold of the
Arctic to the dry and dusty heat of the desert.
fast, easy, on-site maintenance. Clear maintenance
programs reduce long-term maintenance requirements,
providing important benets in the case of remote
installations.

Design and manufacturing specications


In chemical, oil and gas applications, safety must with clients, and the guidelines are mutually agreed
always come rst. ABB motors are designed and upon between ABB and the clients. A few examples
manufactured in accordance with all major national of the increasing numbers of company specications
and international standards, including IEC, ISO, ATEX, which ABB supports are Shell DEP, Saudi Aramco, API
NEMA, CSA and GOST. 541, API 547, ExxonMobil, Chevron Texaco, ADNOC,
Borealis, Repsol, SABIC, SINOPEC, Qatar Petroleum,
A number of company specic design and
PETRONAS, Kuwait Oil Company, KNPC, Engineers
manufacturing specications are taken into account to
India Limited, DOW, BASF, BP, ConocoPhillips, NesteOil
match local engineering practices and requirements.
etc.
Deviation and clarication lists are prepared and
approved in advance for a major proportion of existing For more information on company specic design
specications in order to streamline the technical and manufacturing, please contact your local ABB
ordering procedures. Company specic design and representative.
manufacturing guidelines are completed in collaboration

4 ABB/ BU Machines / HV Motors for COG EN 02-2008

1 COG catalogue_start_excl_DIP.indd 4 25.3.2008 9:33:59


Hazardous areas
Hazardous areas worldwide are classied by zone,
according to the risk posed by explosive gas in the

M000168

M000169
atmosphere.

Division 2
in abnormal conditions

Zone 2
Division 1 Abnormal condition
Occasionally or
continuously
Presence of explosive atmosphere
only by accident, but not during
normal duty ( 10 h per year)
1
Zone 1
Occasionally
Incidental presence of explosive
atmosphere during normal duty
(10 - 1000 h per year)

CE... II 2 G Ex d/Ex de Zone 0


CE... II 2 G Ex e Continously
Permanent presence of
CE... II 2 G Ex p
explosive atmosphere
CE... II 2 G-D Ex d IP65
(> 1000 h per year)

M000176
CE... II 3 G Ex nA
CE... II 3 G-D Ex nA IP55

Classication of hazardous locations according to CENELEC and IEC


The denition of areas according to the Explosive Permanent Incidental Accidental
presence of atmosphere are set up in atmosphere presence presence presence
the following standards: (normal operation (abnormal operation
conditions) conditions)
EN 60079-10 Gas
Gas ('G') Zone 0 Zone 1 Zone 2
IEC 60079-10 Gas

Note: In certain countries Ex d and Ex e motors are also used in Zone 2.

Marking temperatures, gas groups and hazardous areas


To ensure equipment can be safety used in potentially Categories or classication
explosive atmospheres, the hazardous areas where
The ATEX Directive has introduced the concept of
the equipment is installed must be known. Temperature
"Categories" which is a way of expressing the capability
class of equipment must be compared with the
of equipment respecting the EHSR versus the Zone
spontaneous ignition temperature of the gas mixtures
where the equipment is installed.
concerned and its gas group must be known in specic
cases (e.g. ame proof protection).
Category 1 according to Annex 1 of ATEX 95 used
in Zone 0
Category 2 according to Annex 1 of ATEX 95 used
in Zone 1
Category 3 according to Annex 1 of ATEX 95 used
in Zone 2

ABB/ BU Machines / HV Motors for COG EN 02-2008 5

1 COG catalogue_start_excl_DIP.indd 5 25.3.2008 9:34:00


Classication
Category Inammable Level of Fault protection Comparison with present
equipment substances protection practice and IEC
Equipment Methane Very high level 2 types of protection or Group I
group I M1 2 independent faults
(mines)
Methane High level 1 type of protection Group I
M2 Normal operation
Equipment Gas, vapours, Very high level 2 types of protection or Group II
group II 1 mist 2 independent faults Zone 0 (gas)
(surface)
Gas, vapours, High level 1 type of protection Group II
2 mist Habitual frequent malfunction Zone 1 (gas)
Gas, vapours, Normal Required level of protection Group II
3
1 Temperature classes
mist

Grouping of electrical apparatus


Zone 2 (gas)

Temperature Ignition temperature Max. permitted temperature Group I Apparatus for coal mines susceptible to redamp
class for the gas/vapour equipment C
Group II Apparatus for explosive atmospheres other than
C
mines; surface industries
T1 > 450 450
IIA, IIB, IIC Group II is subdivided for Ex d and
T2 > 300 < 450 300 Ex i -equipment according to the severity of the
environment. IIC is the highest rating; a motor
T3 > 200 < 300 200
from one of the higher categories can also be
T4 > 135 < 200 135 used in a lower category environment
T5 > 100 < 135 100
T6 > 85 < 100 85

Marking of equipment
Protection type marking:
EEx according to the EN standards series 50000
Ex according to the EN standards series 60079 and 61241

CE Conformity marking Class I, gases:

CE marking 0081 II 2 G Class I Div 2 Group D T2C


Explosive
Identication number material
of the notied body
responsible for the Incidence of
approval, 0537 VTT (Finland) explosive material
Gas group
The European Commission
mark for Ex products Temperature class

Motor grouping: II for surface


industry (I for mines)
Class I, gases - NEC:
Equipment category: 2 allowed for
Zone 1 (1 for Zone 0,
Class I Zone 2 (A)Ex nA II T2C
3 for Zone 2) Explosive
material
Atmosphere surrounding the motor: G for
explosive gas Incidence of
explosive material
Complementary marking for Ex:
Type of protection and
Ex d IIB T4 apparatus group
with "A" = "American Ex"
without "A" = "Canadian Ex"
Protection type Ex d = ameproof Temperature class
Motor grouping II = for surface industry
Temperature class T4 = max. permitted 135C

6 ABB/ BU Machines / HV Motors for COG EN 02-2008

1 COG catalogue_start_excl_DIP.indd 6 25.3.2008 9:34:00


Main standards complying with the EHSRs of
Products Directive 94/9/EC (ATEX 95)
IEC/EN 60079-0 / General requirements for gas

M000167
EN 50014
IEC/EN 60079-1 / d Protection
ATEX Directives and EN 50018

International Standards IEC/EN 60079-2 /


EN 50016
p Protection

ATEX Directives 95 and 137 IEC/EN 60079-7 / e Protection


EN 50019
ATEX Directives harmonise the safety rules in respect
with the free trading principles of the European
Community.
IEC/EN 60079-15 /
EN 50021
n Protection 1
Now the responsibilities are split in two areas EN 13463-1 General requirements for
between the manufacturers and the end users. The Non-Electrical
manufacturers have to comply with the 'Essential Health
and Safety Requirements' of the Products Directive
94/9/EC, or ATEX 95; and the end users must proceed IECEx Scheme
to make an extensive risks analysis of their 'work
places' and 'work equipment' to full the 'minimum The IECEx Scheme is the International Electrotechnical
requirements' listed in the Worker Protection Directive Commission (IEC) Scheme for certication of equipment
1999/92/EC or ATEX 137. and services for use in explosive atmospheres. The
Scheme is one of three conformity assessment systems
The ATEX Directive 95 apply as of July 1, 2003 for established and operated by the IEC, and is based on
equipment and the Directive 137 for workplaces as of IEC standards. It is a voluntary system which provides
July 1, 2006. The Directives enter into force in each an internationally accepted means of proving that
country with the publication of the corresponding products and services are in compliance with IEC
national regulation. standards. The voluntary and international aspects of
High voltage motors for hazardous areas comply fully the IECEx Scheme differentiate it from certication
with the ATEX product directive 94/9/EC. under ATEX, for example, which is mandatory but
applies only within the European Economic Area. The
According to the new requlations, low voltage motors for IECEx Scheme comprises global certication programs
hazardous areas are exempted from the Low Voltage for both equipment and service facilities.
Directive, the EMC directive as well as the Machinery
Directive. IECEx certication is not the same as IEC certication,
even though both relate to the same IEC standards.
IEC and the corresponding EN Standards are at the The fundamental difference is that IECEx certication
moment in a new process of renewal or revision. In is a quality based system, using a single set of Rules
general old and new standard or revision are both in and Operational Procedures, while IEC certication
parallel valid for about 3 years. This affects mostly the is usually based on product type testing alone. This
marking of the motor, occasionally also new technical means that IECEx certication involves in addition
requirements are introduced. to the product tests assessment of quality control
ABB refers to recently updated standards procedures and testing plans, audits of manufacturing
plants, and routine on-going surveillance and
In the implementation of ATEX 95 and ATEX 137 inspections.
directives ABB refers to the IEC and EN standards
which have been recently updated.
Technical Production Health Maintenance
Main standards for implementation evaluation quality & &
Worker Protection Directive (ATEX 137) per control Safety Repair
sample
IEC/EN 60079-10 Classication of gas areas
IECEx
IEC/EN 50281-3 Classication of dust areas x x x x
Scheme
IEC/EN 60079-14 Installation rules of gas equipment
ATEX x x x x
IEC/EN 60079-17 Inspection and maintenance
rules for gas CSA x x

IEC/EN 60079-19 Repair and overhaul rules IEC x

ABB/ BU Machines / HV Motors for COG EN 02-2008 7

1 COG catalogue_start_excl_DIP.indd 7 25.3.2008 9:34:00


General about hazardous areas
Preamble
In hazardous areas, it is the utmost importance to The hazard may be due to an explosive atmosphere
ensure the safe use of electrical apparatus. To this end, composed of a mixture of gas, vapors or dusts with air.
many countries have regulations concerning both the This chapter only deals with safety in explosive gas
design and use of such apparatus. These regulations atmospheres for which European Standards exist.
are becoming increasingly harmonized within the
framework of IEC recommendations and European
Standards.

1
Non-sparking design, Ex nA
This type of protection is allowed to be used in the
hazardous area corresponding to zone 2.
This design is also known as 'Non-sparking' type as the
motor must be designed in such a way that no sparks
can occur in normal operation, used within the
ratings specied by the manufacturer, which excludes
thermal requirements due to starting or accidental
stalling.

ABB provides non-sparking motors certied according


to ATEX 95 and IEC.

Risk assessment of the Ex nA motors


In order to avoid rotor and stator sparking, the latest
standard requires that a specic risk factor table is used
to identify possible risks (related to the motor's nominal
voltage). If the sum of the risk factors is greater than 5
(rotor) or 6 (stator), either a rotor/stator non-sparking
test must be passed or the motor must be equipped
with a provision for pre-start ventilation. ABB's rotor and
stator designs have passed the required tests.
Ex nA motors can be equipped with provision for
pre-start ventilation. Pre-start ventilation means that
the user can ventilate the enclosure before starting
to ensure that it is free of ammable gases. In this
case the motor is NOT overpressured during normal
operation. Please see page 13 for more details.

8 ABB/ BU Machines / HV Motors for COG EN 02-2008

1 COG catalogue_start_excl_DIP.indd 8 25.3.2008 9:34:00


Increased safety design, Ex e
The design of this motor type prevents the occurrence as measured by the change of resistance method,
of sparks, arcs or hot spots in service (including starting and the maximum temperature rise permitted by the
and locked rotor situation), that could reach the self- winding insulation class.
ignition temperature of the surrounding, potentially
Temperature rise limits during short circuit under
explosive atmosphere, in all inner and outer parts of the
accidental stalling conditions
machine.
Should the machine stall while in operation, a short-
This is ensured by applying constructional or circuit current nearly equal to the starting current will
dimensional provisions that mainly concern: develop, and stator and rotor winding temperatures will
specied minimum values for creepage distances rise rapidly (see gure 1).
and clearances
use of tracking-proof isolating materials
suppression of sharp angles where static electrical
To prevent this temperature value from exceeding the
temperature level below protection devices must trip
within a specied time (tE). This tripping time depends
1
loads could build-up on the short-circuit current level or the short-circuit
ensuring electrical and mechanical assemblies are current to rated current ratio (IA/IN). Figure 2 shows, for
tightly secured commonly used protection devices, the limiting ratio
minimum backlash values between stationary and between short-circuit current inrush IA/IN and rotor
rotating parts (e.g., air gap, ventilation, etc.) stalling time tE, according to the EN.
temperature-rise limits, taking into account locked
rotor, normal operation, accidental mechanical This type of protection is inappropriate for commutator
stalling of machine under the most adverse thermal machines or brake-motors which, by principle, are
conditions, i.e. when thermal equilibrium of machine capable of producing arcs, sparks or hot spots.
is reached while in service.
Temperature rise limits are to be considered for two
operating aspects; one for normal operating conditions
and the other under accidental stalling conditions.
Temperature rise limits under normal operating
conditions
The expected electrical lifespan of a motor depends on Minimum 5 s

its temperature rise for a given insulation class, and on


the motor winding temperature, in operation, which is
not homogeneous with hot spots appearing.
For these reasons, a safety margin of 10 K is allowed
for between windings temperature rise at rated output,

M000173
Figure 2. Min. value of time tE as a function of IA/IN
acc. to EN 60079-7.

Risk assessment of the Ex e motors


In order to avoid rotor and stator sparking, the latest
standard requires that a specic risk factor table is used
to identify possible risks (related to the motor's nominal
voltage). If the sum of the risk factors is greater than
6 (rotor and stator), either a rotor/stator non-sparking
test must be passed and the motor must be equipped
with provision for pre-start ventilation and a space
M000172

heater. ABB's rotor and stator designs have passed the


required tests.
Figure 1.
O = temperature 0C
Ex e motors above 1 kV have to be equipped with a
A = Max. ambient temperature, reference 40C space heater and provision for pre-start ventilation.
B = Temperature at rated load and at worst voltage conditions Pre-start ventilation means that user can ventilate
C = Max temperature as permitted by the insul. class
D = Max limit temperature as set by the nature of the the enclosure before starting to ensure that it is free
potentially explosive atmosphere of ammable gases. In this case the motor is NOT
E = Temperature-rise curve of motor at rated output and at worst
voltage conditions overpressured during normal operation. Please see
F = Temp. rise curve under stalled rotor conditions page 13 for more details.
tE = stalled rotor time

ABB/ BU Machines / HV Motors for COG EN 02-2008 9

1 COG catalogue_start_excl_DIP.indd 9 25.3.2008 9:34:01


Pressurized design, Ex p
Ex p protection prevents the presence of explosive To be installed in zone 1, the motor must comply with
atmospheres inside the motor by the following means: category 2 requirements, even if it is used in zone 2.
- Ex p protection is mainly based on the purging and This type of protection can be used for electrical and
pressurization of the enclosure by clean air or inert non-electrical equipment.
gas.
Motors can be designed with the stator enclosure and
- The enclosure should be purged before starting and
terminal box p protected, or with the stator enclosure
must be overpressured all the time during operation.
p protected and terminal box increased safety e
- The maximum surface temperature inside and
protected.
outside the motor must not exceed the temperature
class for which the motor is certied. The standards concerned with protection type p are
- No arcs or sparks shouldn't occur outside the motor EN 60079-2 and IEC 60079-2 (Electrical apparatus
1 enclosure
The EHSRs of the ATEX Directive corresponding to
for explosive gas atmospheres - Part 2: Pressurized
enclosures p).
category 2 must be followed.

Marking: IEC EN

Stator and Ex px or Ex pz
terminal box p
Stator p and Ex pxe or Ex pze
terminal box e

Type px pressurizing: pressurization that reduces the purged before starting and must be overpressured all
classication within the pressurized enclosure from the time during operation. The overpressure must be at
zone 1 to non-hazardous or group I to non-hazardous. least 50 Pa. If it falls under the trip limit, the electrical
supply should be automatically switched off. The
Type pz pressurizing: pressurization that reduces the
purging gas can be normal air, but it must be supplied
classication within the pressurized enclosure from
from a safe area.
zone 2 to non-hazardous.
Due to the overpressure, the inner part of the enclosure
Equipment must be designed and constructed so that
does not belong to the hazardous area, so the
it prevents ignition sources arising, even in the event
temperature limits for the stator and rotor are the same
of frequently occurring disturbances or equipment
as for a standard machine. The contributions of single
operating faults which normally have to be taken into
fault conditions must still be taken into account (e.g. the
account.
pressure can drop if the pressurized air supply from
Equipment parts must be designed and constructed so the network is lost). This means that all temperatures of
that their stated surface temperatures are not exceeded, inner parts should be under the T-class limit in normal
even in the case of risks arising from situations that are operating conditions.
abnormal anticipated by the manufacturer.
Ex p protection is mainly based on the motors purged
and pressured enclosure. The enclosure should be

10 ABB/ BU Machines / HV Motors for COG EN 02-2008

1 COG catalogue_start_excl_DIP.indd 10 25.3.2008 9:34:01


Flameproof enclosure Ex d and Ex de
The motor enclosure shall be designed in such a on this rated maximum temperature for the considered
way that no internal explosion can be transmitted area.
to the explosive atmosphere surrounding the motor. No motor device outside the ameproof enclosure (e.g.
The enclosure must withstand, without damage, any ventilation) shall be a potential source of sparks, arcs or
pressure levels caused by an internal explosion. The dangerous overheating.
shape, length and gap of part assembly joints, at shaft
opening, cable entries, etc., shall be designed to allow Variants combining two types of protection usually
for throttling and cooling of hot gases escaping outside. combine d and e protection. The most commonly
The standards emphasize the impact of an explosive used and recognized by the CENELEC European
atmosphere (for instance, explosion pressure) over Standards is the Ex de variant. The motor is designed
constructional requirements of such apparatus. with an Ex d ameproof enclosure, while the terminal
Work on assembly devices of enclosure component
parts is only permitted using prescribed tools. Cable
box features an Ex e increased safety protection. Such
design combines the superior safety degree of the 1
d type of protection with the less stringent electrical
entries must meet the requirements of this type of connection requirements of increased safety motors.
protection.
Motors featuring dual protection are seldom
The temperature of the motor's external enclosure encountered - such as an increased safety motor with
should not exceed the self-ignition temperature of the a ameproof enclosure designated Ex e + Ex d in
explosive atmosphere of the installation area during European Standards.
normal operation. For this reason, rated output depends

ABB/ BU Machines / HV Motors for COG EN 02-2008 11

1 COG catalogue_start_excl_DIP.indd 11 25.3.2008 9:34:01


Class I Division 2 / Class I Zone 2
US / Canadian Standards
Motors and generators intended for the US and The following table shows apparatus and gas groups,
Canadian markets must fulll certain NEMA or CSA and also provides an example gas for each group.
standards.
When the main design meets North American Apparatus and Gas groups
standards, the Ex protection and area classication can Apparatus group Gas group Example gas
now be implemented according to two different systems:
I - Mines susceptible Methane
the division system, which has been in use for several
to redamp
years, or the new zone system, which is based on
II - Other places IIA Propane
certain IEC standards.
1 Both systems have similar main classication
arrangements, which are based on the explosive
IIB
IIB + H2
IIC
Ethylene
IIB gases + Hydrogen
Acetylene, Hydrogen
substance in question.
Division system
The division system has been used in North America
Main classications according to NEC or CE Code for a long time and will remain important for many years
to come. At the same time, however, the number of
Class I Gases and vapors (e.g. chemical plant, oil renery)
industrial plants classied according to the zone system
is continuously increasing.
Temperature classes according to NEC and CE Code The system consists of two divisions, which are based
on the incidence of the ammable material.
Temperature class T1 T2 T2A T2B T2C T2D T3
Max temperature / C 450 300 280 260 230 215 200
Incidence of ammable material according to the division
Temperature class T3A T3B T3C T4 T4A T5 T6 system

Max temperature / C 180 165 160 135 120 100 85 Division 1 Flammable gases or vapors are present continuously,
for long period or occasionally in normal operation
Division 2 Flammable gases or vapors are present in abnormal
Zone system conditions only for short periods

NEC and CE Code have introduced a new system to


classify and mark motors and generators. The zone Gas groups
system is directly based on certain IEC standards,
NEC and CE Code have four groups for gases. Note
which dene the zones.
that in the IEC standards IIC is the most and IIA the
The IEC has classied hazardous areas into three least demanding gas group, while in the NEC and
zones based on the incidence of explosive gas or CE Code systems IIA is the most and IID the least
material. demanding group.

Incidence of explosive gas Example gas for each gas group (Class I)

Zone 0 Flammable gases or vapors are present continuously or Gas Group Example gas
for long period
Group A Acetylene
Zone 1 Flammable gases or vapors are likely to exist under
Group B Hydrogen
normal operation
Group C Ethylene
Zone 2 Flammable gases or vapors are not likely to occur in
normal operation and if they do occur, they will exist for Group D Methane, Propane
short periods

All electrical devices have been divided into two groups:


group I for equipment used in mines and group II for
equipment used in surface industry. The design is also
inuenced by the type of gas present, and the IEC
has created three gas groups: A, B and C. These gas
groups are used only for group II apparatus.

12 ABB/ BU Machines / HV Motors for COG EN 02-2008

1 COG catalogue_start_excl_DIP.indd 12 25.3.2008 9:34:01


Testing and certicates
Motors for hazardous areas have to be ofcially ABB's motors conform to the stringent standards set by
approved by a recognized test organization, authorized CENELEC (European Committee for Electrotechnical
to issue test certicates, to ensure compliance with Standardization), and are approved by testing
standards for this type of equipment. laboratories (ExNB: Notied Body). The EU member
countries have a common set of standards for motors
Motors are dened and classied according to the
for hazardous environments.
potentially explosive atmospheres present at the
installation site. Motors can be certied by any of the Notied Bodies
"ExNB" of EU member countries. These motors are
Depending on the nature of the atmosphere, it is the
therefore acceptable in all EU countries and many other
responsibility of the user to determine which group
countries.
and which maximum surface temperature should be
specied for the motor installation. The following global certicates are available: IEC,
IECEx Scheme, ATEX, CSA and CSA / US. National
1
The motors are rated and certied for ambient
certicates available include GOST-R (Russia), GOST-K
temperature between 20C and +40C according to
(Kazakhstan), Inmetro (Brazil), CQST (China), KOSHA
standards. For ambient temperatures below 20C and
(Korea) and CCE / DGFASLI (India). Local certications
above +40C certicates are available for most of the
are mainly obtained on the basis of IEC or ATEX.
motors.

Risk assessment and gas tests


Non-sparking (Ex nA) and increased safety (Ex e) ABBs approach to meet the new requirements
motors have to meet tough requirements with regard
Following a program of gas environment tests in which
to sparking. The latest IEC and EN standards specify
all tests were passed, ABB has secured certication for
criteria for risk assessment and gas environment tests
its HXR, AMA, AMI and M3GM motors, frame size up to
for rotor and stator designs to show that the motors are
630 mm, as follows:
spark-free in all operational conditions.
- All rotor tests passed
By testing and securing certication for its motors, ABB - Stator tests passed up to 13.2 with Group IIC gases*
is helping to streamline the risk assessment process for - Stator tests passed up to 15 kV with Group IIA and
its customers. Due to these tough tests to be fullled, it IIB gases*
re-inforce the insulation system and increase the time
life of products. For higher voltage levels pre-start ventilation or risk
assessment can be used.
The alternative to testing and certication involves,
in the majority of cases, equipping the motor with * Examples of gases in the three groups
IIA: methane, benzene, ammonia
provision for pre-start ventilation. This means investing
IIB: ethylene, propyne, nitroethane
in a higher capacity air compressor, piping, and a IIC: hydrogen, acetylene and carbon disulphide
ventilation control unit. It also requires an additional
operation ventilation every time the motor is started. Note:
Examples of gases in the four groups according to North American
Benets of the ABB approach therefore include Division system are:
reduced initial capital expenditure, lower operating - Group A: Acetylene
costs, and faster starting. Reliability is improved as no - Group B: Hydrogen
additional components are required. Most importantly, - Group C: Ethylene
- Group D: Propyne
ABBs certied motors offer proven safety, as testing
represents the only way to verify that equipment is
really safe.

ABB/ BU Machines / HV Motors for COG EN 02-2008 13

1 COG catalogue_start_excl_DIP.indd 13 25.3.2008 9:34:01


High voltage general technical specication
Mounting arrangement
Standard mounting arrangements for AMA motors.
Other mountings on request.

2
Code I: IM B3 Code I: IM V1
Code II: IM 1001 Code II: IM 4011
Horizontal foot mounted Vertical ange mounted
(free shaft end facing downwards)

Standard mounting arrangements for HXR motors

Code I: IM B3 Code I: IM V1
Code II: IM 1001 Code II: IM 3011
Standard oor mounting, feet facing downwards Flange and free shaft end facing downwards
(Horizontal foot mounted) (Vertical solid shaft, ange mounted)

14 ABB/ BU Machines / HV Motors for COG EN 02-2008

2 COG catalogue_general technical spec.indd 14 25.3.2008 9:37:43


Standard mounting arrangements for AMD motors,
which are in accordance with IEC 60034-7:

Code I: IM B3
Code II: IM 1001
Code I: IM B3
Code II: IM 1001
2
Horizontal foot mounted Horizontal foot mounted
Cooling method IC 411 Cooling method IC 511

Code I: IM V1
Code II: IM 4011
Vertical ange mounted (free shaft end facing downwards)

For AMD 355g and AMD 400g Code II: IM 3011


Other mountings types are available on request.

ABB/ BU Machines / HV Motors for COG EN 02-2008 15

2 COG catalogue_general technical spec.indd 15 25.3.2008 9:37:52


Voltage levels
The table below shows the Ex protection types, zones, areas. The supply voltage tolerance for IEC motors is in
temperature classes, altitudes and voltage limits accordance with zone B (IEC 60034-1).
applicable to ABBs high voltage motors for hazardous

Protection type Permitted Motor type Temperature Maximum supply voltage


in Zone classes

Ex nA 2 HXR, AMA, T1-T4 11 kV + IEC tolerance Zone B or 11.5 kV + IEC tolerance Zone A 1)
M3GM T1-T3 6.6 kV + IEC tolerance Zone A or B 4)
Ex px 1 and 2 HXR, AMA T1-T4 like standard motors
Ex pxe 1 and 2 HXR, AMA T1-T4 11 kV + IEC tolerance Zone B
Ex e 1 and 2 HXR, AMA T1-T3 7.2 kV + IEC tolerance zone B, if the stator gas test is passed
5.9 kV, if the stator gas test is not passed
Ex d 1 and 2 AMD R / AMD T T3/T4 like standard motor

2 Ex de
Class I Division 2 / N/A
Class I Zone 2
1 and 2 AMD R / AMD T
HXR, AMA
T3/T4
T1-T4
10.5 kV + IEC tolerance Zone B 3)
11 kV + NEMA tolerance 2)
AMI T1-T4 13.2 kV + NEMA tolerance 2)
M3GM T1-T3 4.16 kV + NEMA tolerance
Class I Zone 1 N/A AMD R / AMD T T3/T4 like standard motor
Ex d / AEx d
Class I Zone 1 N/A AMD R / AMD T T3/T4 10.5 kV + IEC tolerance Zone B 3)
Ex de / AEx de
1) Please contact the factory, if the supply voltage for Ex nA motors exceeds 6.6 kV. Special design features will be required. Even with the special design, the
maximum supply voltage is 11 kV + IEC tolerance zone B.
2) Please contact the factory if the supply voltage for Class I Division 2 / Class I Zone 2 motors exceeds 6.6 kV. Special design features will be required.
Note: 13.8 kV NEMA motors are only available with 5% tolerance at the rated frequency.
3) Maximum value accepted by CESI.
4) IEC tolerance according to zone A for generation code A motors and zone B for generation code B motors.

16 ABB/ BU Machines / HV Motors for COG EN 02-2008

2 COG catalogue_general technical spec.indd 16 25.3.2008 9:37:52


High voltage motors and frequency converters for
hazardous areas
Frequency converters provide signicant benets when Pressurized motors (Ex px, Ex pz)
used with motors for hazardous areas. The advantages Certication can be based on type testing or calculation,
include better process control through regulation of the depending on the agreement between the manufacturer
motor speed, as well as energy savings, and therefore and certication authority. The internal overpressure
improved environmental performance. must be maintained over the whole speed range and it
Certain criteria must be taken into account to ensure that must be veried during the nal test.
the combination of frequency converter and motor can be All Ex px motors must be certied by an authorized
used safely. The requirements depend on the protection certication body (third party certication). In the
type in use. The motor can either be considered as a case of Ex px motors the process must be carried out
separate entity, or as part of a system, which is how most separately for each completely identical motor series.
motor users view the situation. The certicate is supplied to the customer after nal
ABB offers hazardous area motors for use with variable testing at the factory. The certicate is typically motor
specic.
speed drives with the following protection types:
ameproof, increased safety, non-sparking, and dust
ignition protected.
Certicates for Ex pz motors can be issued by the
factory or authorized certication body (third party
2
certication). The certicates can be either motor
specic or standard.
Main requirements for
Flameproof motors (Ex d, Ex de)
hazardous area motors used
Certication can be based on type testing or calculation,
with variable speed drives depending on the agreement between the manufacturer
Non-sparking motors (Ex nA) and certication authority.
Certication can be based on type testing or calculation, Ex d motors used with a frequency converter are
depending on the agreement between the manufacturer certied as a motor series by an authorized certication
and certication authority. body (third party certication). The certication is
Certicates for Ex nA motor & frequency converter independent of the converter type (ABB or other). The
combinations can be issued by the factory or authorized descriptive documentation for the motor must include
certication body (third party certication). Many Ex nA the necessary parameters and conditions required for
motors already have standard type certicates for use use with a converter.
with ABB frequency converters, including the ACS 600,
ACS 800 and ACS 1000 converters.
Increased safety motors (Ex e)
An Ex e motor supplied by a frequency converter must
be tested and certied for this duty as a unit. This
means that the combined heat run test (temperature
rise test with frequency converter) is compulsory for
frequency converter supplied motors.
All Ex e motors used with a frequency converter
must be certied by an authorized certication body
(third party certication). In the case of Ex e motors
the process must be carried out separately for each
completely identical motor series with an identical
frequency converter. The certicate is supplied to the
customer after nal testing at the factory. The certicate
is typically motor specic.

ABB/ BU Machines / HV Motors for COG EN 02-2008 17

2 COG catalogue_general technical spec.indd 17 25.3.2008 9:37:52


Combinations of Ex motors with VSDs
The table below shows the available combinations of deviations from the information shown in the table will
VSDs and motor protection types in continuous duty. be accepted. Please contact ABB for further information.
In cases when a converter is used as a soft starter,

ACS 600/800 ACS 1000 ACS 5000 ACS 6000 LCI Other drives 1)

Ex nA Available Available Available* Not available Not available Veried at the


factory
Ex e Available Available Not available Not available Not available Veried at the
factory
Ex px, Ex pz Available Available Available Available Available Veried at the
factory
Ex d, Ex de Available Available Veried at the Veried at the Not available Veried at the
factory 2) factory 3) factory
Class I Zone 1 4) Available Available Veried at the Veried at the Not available Veried at the

2 Class I Div 2
Class I Zone 2
Available Available
factory 2)
Available*
factory 3)
Not available Not available
factory
Veried at the
factory
1)
Some non-sinusoidal supplies can be approved for other drives in case of Ex p. Minimum criterion is proofed sinusoidal supply in case of other MV drives for all
other protection types.
2)
Use of grounding brushes is recommended, and will be evaluated on a case-by-case basis by the factory.
3)
AMD motors with ACS 5000 and ACS 6000 converters are quite seldom required due to low maximum supply voltage level of AMD motors.
4)
Available only for AMDR IIB motors.
* For induction motors only.

Requirements for Ex motors with converter supply according to IEC and ATEX
Protection Product Requirements / ATEX 95 Installation Requirements / ATEX 137

Minimum requirements EN/ IEC 60079-0/EN 50014 2.4 Explosion protection measures
Precaution shall be taken to guard against any effect equipment,and any associated connecting
due to the presence of circulating currents devices must only be brought into service if the
explosion protection document indicates that they
can be safely used in an explosive atmosphere.

n Non Sparking EN 50021 / IEC 60079 -15 EN / IEC 60079 -14


The motors shall be tested for this duty with the To prevent any over-voltage spikes and higher
converter specied. In exceptional cases the temperatures in the motor.
temperature class may be determined by calculation.

eIncreased Safety EN 50019 / IEC 60079 -7 EN / IEC 60079 -14


The combination shall be tested as a unit with the The combination shall be tested as a unit with the
associated protective device. associated protective device.
To prevent any over-voltage spikes and higher
temperatures in the motor and bearing currents.

pPressurized EN 50016 / IEC 60079 -2 EN / IEC 60079-14


The safety of the combination shall be shown by No specic requirements.
calculations or other measures. The operational speed
range must determine the position and pressurization
of the minimum pressure point within the enclosure.
Electronic safety control equipment must be certied or
duplicated two independent faults.

dFlame Proof EN 50018 / IEC 60079 1 EN / IEC 60079-14 10.5


No specic requirements a) Either a direct temperature control by embedded
NB Clarication sheet 00/02/059/CS temperature sensors or other effective measures.
The combination shall be design and tested always The action of the protective device shall be to
as a unit with converter parameters listed, or direct cause the motor to be disconnected. The motor and
thermal protection with sufcient margin to protect converter combination does not need to be tested
bearings or rotor. together; or
Analysis of converter control electronic according to b) the motor shall have been type-tested for this
IEC 61508 or duplication of protection. duty as a unit in association with the converter and
with the protective device provided.

18 ABB/ BU Machines / HV Motors for COG EN 02-2008

2 COG catalogue_general technical spec.indd 18 25.3.2008 9:37:52


High voltage
Non-sparking Ex nA motors
Totally enclosed squirrel cage three phase
high voltage motors,
Sizes 315 - 450, 110 to 750 kW
For Zone 2

www.abb.com/motors&generators
> Motors
>> Motors and Generators for Hazardous Areas

Mechanical design........................... 20
Rating plates..................................... 30
Ordering information....................... 31
Technical data.................................. 32
Variant codes.................................... 48
Dimension drawings........................ 50
Accessories...................................... 53
Construction..................................... 55
Cast iron motors in brief................. 56

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 19


Mechanical design
This part of the section describes standard high engineered cast iron motor, please see the motor types
voltage motors for non-sparking protection, with limited described later in this section.
optional features and accessories. In case you need an

Stator frame
The motor frames including feet and bearing housing Motors can be supplied for foot mounting (horizontal),
are made of cast iron. The terminal boxes are made foot and ange mounting (horizontal) or ange mounting
of structural steel. Integrally cast feet allow a very rigid (vertical).
mounting and minimal vibration.

Protection against corrosion


Special attention has been paid to the nish of ABB's The color is blue, Munsel color code 8B, 4.5/3.25
motors. All parts are treated by the method most (NCS4822-B05G the closest shade in other standards).
appropriate to each material, giving reliable anti- Specic details of paint types are available on request.
corrosion protection under severe environmental
conditions.

3 Drain holes
Non-sparking high voltage motors are tted with drain For applications with a vertical mounting, the upper
holes and closable plugs. The drain hole plugs are open plug must be hammered home completely. In very dusty
on delivery and users must ensure that the drain holes environments, both plugs should be hammered home.
face downward when mounting the motors.

Closed

Open

Non-sparking motors
As standard with drain holes and closable plugs.
M000241

20 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Terminal boxes
The high voltage terminal box is shown below. The main
technical data are listed below.
Technical data: Materials:
Voltage (max.) 6.6 kV Box welded structural steel
Current (max.) 400 A (thickness min. 3 mm)
No of cables (max.) 1 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland plate Isolators epoxy casting resin or
(1 pcs) polyurethane resin
Clearance (min.) 60 mm Grounding pad stainless steel
Creepage (min.) 90 mm
Gross volume 47.3 dm3 Other features:
Usable volume 42.1 dm3 - rigid welded construction
Connection screws M16 (3 pcs) - ample size for making connections of supply cables
Connection nuts tightening torque 40 Nm - box turnable to allow cable entry from left or right side
Ground connections M12 (both in- and
- box turnable in steps of 90
outside)
Weight 33 kg - either 3-phase or 1-phase cables can be connected
Protection IP 66 - pressure relief plate in the bottom of the box in case of
Standard DIN 42962 an arching short circuit
TEIL 1, A2
Dynamic short circuit current 30 kA rms x 0.25s/
75 kA peak
3

M000243

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 21


The high voltage star point terminal box is shown below
(option, variant code 750). The main technical data are
listed below.

Technical data: Materials:


Voltage (max.) 6.6 kV Box welded structural steel
Current (max.) 400 A (thickness min. 3 mm)
Cable gland blind gland plate Cable gland plate steel
(1 pcs) Connection screws Bronze Bz
Creepage (min.) 90 mm Connection bar Copper Cu
Gross volume 47.3 dm3 Isolators epoxy casting resin or
Usable volume 42.1 dm3 polyurethane resin
Connection screws M16 (3 pcs) Grounding pad stainless steel
Connection nuts tightening torque 40 Nm
Ground connections M12 (both in- and Other features:
outside) - rigid welded construction
Weight 33 kg - box turnable to left or right side
Protection IP 66 - box turnable in steps of 90
Dynamic short circuit current 30kA rms x 0.25 s/ - pressure relief plate in the bottom of the box in case
75 kA peak - of an arching short circuit

M000244

22 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Star point terminal box (optional)

M000245
Delivery without main terminal box (optional)

M000360
M000359

Dimensions for terminal box inlet, blind gland plate


M000246

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 23


Auxiliary boxes
Auxiliary terminal box is used for control equipment and
heating elements.
Specication: Other features:
- default one box - equipped with assembly rail ARH 22
- stator Pt-100 (DIN-35, 35x203 mm)
- bearing Pt-100 (optional, variant code 107) - main dimensions 125x222x81
- separate box for heating elements - degree of protection IP 66 (IEC 529)
- gasket material polyurethane
Specication: - temperature resistance -55 - +80C
- max. terminal blocks: 34 pcs 2.5 mm2
Material designation Al-Si10Mg (pressure die cast) 28 pcs 4.0 mm2
Material standard EN 573-3 - weight 1.6 kg
Surface treatment RAL 7001 (grey)

Accessory box

M000248
M000247

Accessory box for heating elements


M000249

24 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Bigger auxiliary box

M000355

M000356
- one box as default Other features:
- stator Pt-100 (6 pcs) - equipped with assembly rail ARH 22 (DIN-35)
- bearing Pt-100 (optional, variant code 107)
- separate box for heating element (variant
- main dimensions 230x330x180
- degree of protection IP66 (IEC 529) 3
code 450/451) - gasket material silicone
- dial type thermometers for bearings - temperature resistance -55 - +100C
(optional, variant code 651/652)* - weight 5.6 kg
- Pt-100 (12 pcs) inside stator slots
(optional, variant code 653)* Specication:
- Provision for vibration sensors (optional, Material designation Al-Si12Mg (die cast)
variant code 654)* Material standard EN 573-3
* The bigger auxiliary box is needed if any of Surface treatment RAL 7001 (grey)
these variant codes is selected.

M000358
M000357

Option with bearing dial type thermometers


- Measuring range 0120 C - Temperature durability of capillary tube
- Degree of protection: IP65 (IEC529) -40+100 C
- Temperature durability of display -40+60 C - Without contacts (optional, variant codes 651)
- Ex i approved

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 25


Bearings
The motors are normally tted with single-row deep If the bearing at the D-end is replaced with a roller
groove ball bearings as listed in the table below. bearing (NU-), higher radial forces can be handled.
Roller bearings are suitable for belt drive applications.

Basic version with deep groove ball bearings Version with roller bearings, variant code 037
Motor Number Deep groove ball bearings Motor Number Roller bearings, variant code 037
size of poles D-end N-end size of poles D-end
315 2 6316M/C3 6316M/C3 315 4-6 NU 319/C3
4-6 6319/C3 6316/C3 355 4-6 NU 322/C3
355 2 6316M/C3 6316M/C3 400 4-8 NU 324/C3
4-6 6322/C3 6316/C3 450 4-8 NU 326/C3
400 2 6317M/C3 6317M/C3
4-8 6324/C3 6319/C3
450 2 6317M/C3 6317M/C3
4-8 6326M/C3 6322/C3

3 Axially-locked bearings
All motors are equipped as standard with an axially- The N-end bearing is axially free and can take the
locked bearing at the D-end. thermal expansion. Note! NU-bearing is axially locked at
N-end.
The bearing's outer ring is tightly locked between
bearing's covers and tight t of the housing t.

Transport locking
Motors with roller bearings are tted with a transport Locking may also be tted in other situations where
lock to prevent damage to the bearings during the transport conditions are considered as potentially
transport. All high voltage motors are tted with a damaging.
warning sign when the transport lock is tted to prevent
operational damage and alert operations.

26 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Bearing seals
All high voltage motors are equipped with labyrinth
sealed bearings.

Axially free (N-end)

M000251
M000250
3
Axially locked (D-end)

M000253
M000252

Vibration levels / Balancing


Motors are balanced according to ISO1940:1998 The following table lists the vibration values that the
standard, balancing grade G2.5. motors full in compliance with IEC 60034-14.

Poles Speed r/min Design Bearing housing


vibration
2 1800 < n 3600 Standard 2.3 mm/s rms
4 1800 Standard 2.3 mm/s rms

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 27


Bearing life
The nominal life L10 of a bearing is dened according test series under certain specied conditions. 50% of
to ISO 281 as the number of operating hours achieved the bearings achieve at least ve times this gure.
or exceeded by 90% of identical bearings in a large

Lubrication
On delivery, the motors are pre-lubricated with high Motors with relubrication nipples
quality grease. The grease grade is stamped on the
Motors are lubricated while running and the bearing
lubrication plate fastened to the motor frame. See page
system on all high voltage motors has been built so that
30 for an example of a lubrication plate.
a valve disc can be used for lubrication.
More information about lubrication and greases can
The grease outlet opening has closing valves at both
be found in ABB's High Voltage Process Performance
ends that should be opened before greasing and closed
Manual delivered with the motor.
1-2 hours after regreasing. Closing the valves ensures
that the construction is tight and dust or dirt cannot get
inside the bearing.

Lubrication intervals
Frame 3000 1500 <1000
The lubrication interval is dened by following the size Ambient C r/min r/min r/min

3 L1-principle. This means that 99% of ABB's motors


will achieve the normal service intervals. Values for the
lubrication intervals can also be calculated according to
Roller bearings: lubrication intervals in duty hours
315 25 - 4400 8800
315 40 1) - 2200 5100
the L10-principle, which are normally doubled compared 355 25 - 4400 4400
to L1-values. Values are available from ABB on request. 355 40 1) - 2200 2200
The table below gives lubrication intervals for different 400 25 - 3000 4400
speeds (according to the L1-principle). The values are valid 400 40 1) - 1500 2200
for motors using the synthetic base oil mentioned in ABBs 450 25 - 3000 4400
High Voltage Process Performance Motors Manual. 450 40 1) - 1500 2200
1)
For generation code B motors, same lubrication intervals are
For more information, see ABB's High Voltage Process valid for 50C ambient.
Performance Motors Manual.

Frame 3000 1500 <1000 Frame 3000 1500 <1000


size Ambient C r/min r/min r/min size Ambient C r/min r/min r/min
Ball bearings, horizontal motor: lubrication intervals in duty hours Ball bearings, vertical motor: lubrication intervals in duty hours
315 25 5900 8800 8800 315 25 - 6600 8800
315 40 1) 3000 6600 8800 315 40 1) - 3600 4400
355 25 4400 8800 8800 355 25 - 4400 8800
355 40 1) 2200 5100 8800 355 40 1) - 2200 4400
400 25 3000 6600 8800 400 25 - 3000 6600
400 40 1) 1500 3600 8000 400 40 1) - 1500 3600
450 25 3000 6600 8800 450 25 - 3000 6600
450 40 1) 1500 3600 8000 450 40 1) - 1500 3600
1)
1)
For generation code B motors, same lubrication intervals are For generation code B motors, same lubrication intervals are
valid for 50C ambient. valid for 50C ambient.

Pulley diameter
When the desired bearing life has been determined, where:
the minimum permissible pulley diameter can be D= diameter of pulley, mm
calculated using FR, as follows: P= power requirement, kW
n = motor speed, r/min
D=
1.9 107 K P K= belt tension factor, dependent on belt type
n FR and type of duty. A common value for
V-belts is 2.5.
FR = permissible radial force

28 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Permissible loadings on shaft
The tables give the maximum permissible radial force the permissible force FR can be calculated from the
in Newtons, assuming zero axial force. The values are following formula:
based on normal conditions at 50 Hz and calculated
bearing lives L10h for 40,000 hours. FR = FX0 - X (FX0 - FXmax)
E
Motors are foot-mounted IM 1001 (B3) version with E = length of shaft extension in basic version
force directed sideways. In some cases the strength of
the shaft affects the permissible forces.
Permissible loads of simultaneous radial and axial forces
will be supplied on request.
If the radial force is applied between points X0 and Xmax,

M000021
Permissible radial forces
Length of Ball bearings Roller bearings
shaft
extension
Motor 40,000 hours 40,000 hours
E (mm)
size Poles FX0 (N) FXmax(N) FX0 (N) FXmax(N)
315LK 2
4
140
170
4850
7900
4300
6850
-
25000
-
9500 3
6 170 9050 7850 30000 9500
355LK 2 140 2350 2150 - -
4 210 9900 8600 25000 12000
6 210 11500 9950 40000 12000
400L / LK 2 170 550 500 - -
4 210 8130 7160 25000 15000
6-8 210 10190 8900 45000 15000
450L 2 170 - - - -
4 210 8950 7950 25000 20800
6-8 210 10430 9250 50000 20800

Permissible axial forces


The following tables give the permissible axial forces Given axial forces FAD, assumes D-bearing locked by
in Newton, assuming zero radial force. The values are means of locking ring.
based on normal conditions at 50 Hz with standard
bearings and calculated bearing lives L10h 40,000 hours.

Mounting arrangement IM B3 Mounting arrangement IM V1


FAZ


FAD   FAZ 
M000022

M000023

FAD

40,000 hours 40,000 hours


2-pole 4-pole 6-8-pole 2-pole 4-pole 6-8-pole
Motor FAD FAZ FAD FAZ FAD FAZ Motor FAD FAZ FAD FAZ FAD FAZ
size N N N N N N size N N N N N N
315LK 2050 4050 4150 6150 5050 7050 315LK - - 7650 3750 9150 4350
355LK 850 4650 4350 8150 5650 9450 355LK - - 10900 3850 12700 4600
400L / LK 200 5200 2990 8990 3970 9970 400L / LK - - 11550 2780 15100 2480
450L - - 3200 9200 4220 10220 450L - - 15420 800 19080 380

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 29


Rating plates

Rating plate Lubrication plate

M000254

M000255
3 Restamping output, voltage, ambient and altitude
Motor catalogue ratings can be re-stamped as follows. Ambient temperature
Motor construction will not be changed but a new
rating plate and data sheet can be created with variant Motor can be de-rated to higher ambient temperatures.
code 002. In all the below cases or their combinations, Maximum ambient temperature is 55 C. The output
please contact ABB for correct motor size and motor has to be de-rated so that absolute temperature will not
data. Bearing re-lubrication intervals as shown in this be higher than the catalogue data.
catalogue are valid also for re-stamped motors. Altitude
Output Motor can be de-rated to higher altitudes than standard
Output can be re-stamped downwards from the 1000 meters above sea level. There are different
catalogue data. maximum altitude limits for different motors depending
on voltage level. The motor output has to be de-rated so
Voltage that the absolute temperatures of the motor will not be
higher than the catalogue data.
Voltage can be re-stamped downwards up to 10%
from the motor nominal voltage in the catalogue. Motor Note: M3GM (Ex) motors for higher than 1000 meters
output has to be de-rated so that the motor absolute above sea level altitude can be offered only case by
temperatures will not be higher compared to catalogue case from the manufacturing unit.
data.

30 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Ordering information
Sample order
When placing an order, please state the following Motor type M3GM 315LKA
minimum data in the order, as in example. Pole number 4
Mounting arrangement (IM code) IM B3 (IM 1001)
The product code of the motor is composed in Rated output 110 kW
accordance with the following example. Product code 3GGM312810-AQA
Variant codes if needed

Motor size
A Motor type
A B C D, E, F, G B Motor size
C Product code
M3GM 315LKA 3 G GM 312 810 - A Q A 003 etc. D Mounting arrangement code
E Voltage and frequency code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 F Generation code
G Variant codes

Explanation of the product code:


Positions 1 to 4 Position 11
3GGM = Totally enclosed fan cooled squirrel cage motor with cast - (dash)
iron frame, high voltage
Position 12
Positions 5 and 6 Mounting arrangement
IEC-frame
31 = 315
35 = 355
A = Horizontal
B = Vertical
H = Foot- and ange-mounted, terminal box top-mounted
3
40 = 400
45 = 450
Position 13
Position 7 Voltage and frequency code
Speed (Pole pairs) See table below
1 = 2 poles Position 14
2 = 4 poles Generation code
3 = 6 poles A, B, C...
4 = 8 poles A = Motor designed for 40C ambient
B = Motor designed for 50C ambient
Position 8 to 10
Serial number The product code must be, if needed, followed by variant codes.

Code letters for supplementing the product code - single speed motors
Code letter for voltage and frequency at 50 Hz
Q R S T
3000 V 3300 V 6600 V 6000 V

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 31


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 40C
Efciency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A
3000 r/min = 2 poles 3000 V 50 Hz
132 M3GM 315 LKA 3GGM  s1! 2971 94.5 94.4 0.92 0.92 29 6.2 5
155 M3GM 315 LKB 3GGM  s1! 2972 94.8 94.7 0.92 0.92 34 6.5 6
4)
200 M3GM 355 LKA 3GGM  s1! 2974 94.7 94.6 0.90 0.90 45 5.5 9
4)
250 M3GM 355 LKB 3GGM  s1! 2975 95.3 95.2 0.90 0.90 56 6.0 11
4)
310 M3GM 355 LKC 3GGM  s1! 2973 95.8 95.8 0.91 0.92 68 5.9 11
4)
315 M3GM 355 LKD 3GGM  s1! 2974 95.8 95.9 0.91 0.92 69 6.3 11
4)
345 M3GM 355 LKE 3GGM  s1! 2983 96.1 96.0 0.91 0.90 76 6.5 15
4)
355 M3GM 400 LA 3GGM  s1! 2980 95.9 95.8 0.90 0.90 79 6.2 16
4)
400 M3GM 400 LB 3GGM  s1! 2978 96.2 96.2 0.91 0.91 88 6.1 15
4)
440 M3GM 400 LC 3GGM  s1! 2979 96.3 96.3 0.91 0.92 96 6.5 16
4)
500 M3GM 400 LKA 3GGM  s1! 2983 96.6 96.6 0.91 0.91 109 6.1 19
4)
555 M3GM 400 LKB 3GGM  s1! 2983 96.8 96.8 0.91 0.92 121 6.1 19
4)
630 M3GM 450 LA 3GGM  s1! 2986 96.9 96.8 0.91 0.91 138 6.4 26
4)
700 M3GM 450 LB 3GGM  s1! 2986 97.0 97.0 0.91 0.91 152 6.5 27
3000 r/min = 2 poles 3300 V 50 Hz
160 M3GM 315 LKA 3GGM  s2! 2976 94.9 94.8 0.91 0.91 32 6.3 6

3 200
250
310
4)
4)
4)
M3GM
M3GM
M3GM
355 LKA
355 LKB
355 LKC
3GGM
3GGM
3GGM
 s2!
 s2!
 s2!
2977
2975
2975
94.8
95.3
95.8
94.5
95.2
95.8
0.89
0.90
0.91
0.89
0.90
0.92
41
51
62
6.1
6.0
6.4
9
10
11
4)
330 M3GM 355 LKD 3GGM  s2! 2975 96.0 96.0 0.91 0.92 66 6.5 11
4)
355 M3GM 400 LA 3GGM  s2! 2979 96.0 95.9 0.90 0.90 72 6.2 14
4)
400 M3GM 400 LB 3GGM  s2! 2978 96.1 96.1 0.91 0.91 80 6.1 14
4)
435 M3GM 400 LC 3GGM  s2! 2977 96.3 96.4 0.91 0.92 86 6.3 14
4)
500 M3GM 400 LKA 3GGM  s2! 2982 96.6 96.6 0.91 0.92 99 5.9 16
4)
555 M3GM 400 LKB 3GGM  s2! 2983 96.8 96.8 0.91 0.92 110 6.1 17
4)
630 M3GM 450 LA 3GGM  s2! 2986 96.9 96.8 0.91 0.91 125 6.4 24
4)
700 M3GM 450 LB 3GGM  s2! 2986 97.0 97.0 0.91 0.91 138 6.5 24
3000 r/min = 2 poles 6000 V 50 Hz
4)
250 M3GM 355 LKA 3GGM  s4! 2975 95.2 95.2 0.91 0.92 28 6.1 5
4)
280 M3GM 355 LKB 3GGM  s4! 2982 95.6 95.5 0.91 0.90 31 6.2 6
4)
300 M3GM 355 LKC 3GGM  s4! 2982 95.8 95.7 0.91 0.91 33 6.2 6
4)
315 M3GM 400 LA 3GGM  s4! 2981 95.5 95.4 0.89 0.88 35 6.4 8
4)
355 M3GM 400 LB 3GGM  s4! 2979 95.9 95.8 0.91 0.91 39 6.3 7
4)
390 M3GM 400 LC 3GGM  s4! 2978 96.0 96.0 0.91 0.91 43 6.3 8
4)
410 M3GM 400 LD 3GGM  s4! 2979 96.2 96.2 0.92 0.92 45 6.6 8
4)
450 M3GM 400 LKA 3GGM  s4! 2983 96.3 96.3 0.91 0.91 49 6.0 9
4)
500 M3GM 400 LKB 3GGM  s4! 2984 96.5 96.5 0.91 0.91 55 6.4 10
4)
530 M3GM 400 LKC 3GGM  s4! 2984 96.6 96.7 0.92 0.92 58 6.4 10
4)
560 M3GM 450 LA 3GGM  s4! 2986 96.6 96.5 0.90 0.90 62 6.3 13
4)
630 M3GM 450 LB 3GGM  s4! 2986 96.8 96.7 0.91 0.91 69 6.4 12
4)
670 M3GM 450 LC 3GGM  s4! 2986 97.0 96.9 0.92 0.92 73 6.5 13
3000 r/min = 2 poles 6600 V 50 Hz
4)
280 M3GM 355 LKA 3GGM  s3! 2982 95.5 95.5 0.91 0.91 28 6.1 5
4)
315 M3GM 400 LA 3GGM  s3! 2980 95.6 95.4 0.90 0.89 32 6.4 7
4)
355 M3GM 400 LB 3GGM  s3! 2980 95.8 95.7 0.91 0.91 36 6.3 7
4)
395 M3GM 400 LC 3GGM  s3! 2979 96.1 96.0 0.91 0.91 39 6.5 7
4)
415 M3GM 400 LD 3GGM  s3! 2979 96.2 96.2 0.91 0.92 41 6.6 7
4)
450 M3GM 400 LKA 3GGM  s3! 2983 96.3 96.4 0.91 0.91 45 6.0 8
4)
500 M3GM 400 LKB 3GGM  s3! 2984 96.5 96.5 0.91 0.91 50 6.5 9
4)
530 M3GM 400 LKC 3GGM  s3! 2984 96.6 96.7 0.92 0.92 52 6.4 9
4)
560 M3GM 450 LA 3GGM  s3! 2986 96.6 96.5 0.90 0.90 56 6.2 11
4)
630 M3GM 450 LB 3GGM  s3! 2986 96.8 96.7 0.91 0.91 63 6.4 12
4)
670 M3GM 450 LC 3GGM  s3! 2986 96.9 96.9 0.91 0.92 66 6.3 11
The bullet in the product code indicates choice of mounting
When ordering variant code for protection type has to be added
arrangement (see ordering information page).
to the product code according to needs:
456 Ex nA design, fullling IEC 60079-15, with certicate.
480 Ex nA II according to ATEX directive 94/9/EC, temperature
class T3.

32 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 40C
Torque Load Starting Maximum Rotor Rotor Motor Sound
TN TS Tmax Power inertia time stalling inertia weight weight pressure
1)
Output Motor type factor cold 2) time hot kgm2 kg kg level LP 3)
kW Nm TN TN cos k kgm2 s s dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


132 M3GM 315 LKA 424 1.2 2.6 0.17 10 8 16 2.0 230 1230 78
155 M3GM 315 LKB 498 1.3 2.8 0.17 12 7 16 2.1 240 1260 78
4)
200 M3GM 355 LKA 642 0.8 2.4 0.13 15 11 22 2.9 280 1680 78
4)
250 M3GM 355 LKB 803 0.9 2.6 0.13 18 9 16 3.2 300 1780 78
4)
310 M3GM 355 LKC 996 1.0 2.5 0.13 22 8 16 4.5 390 2150 78
4)
315 M3GM 355 LKD 1011 1.1 2.6 0.14 22 7 14 4.2 420 2240 78
4)
345 M3GM 355 LKE 1104 1.0 2.7 0.13 24 8 14 4.1 400 2220 78
4)
355 M3GM 400 LA 1138 0.9 2.6 0.13 24 9 20 6.9 460 2410 79
4)
400 M3GM 400 LB 1283 1.0 2.5 0.14 27 9 20 8.0 520 2660 79
4)
440 M3GM 400 LC 1411 1.1 2.6 0.14 29 7 16 7.8 580 2900 79
4)
500 M3GM 400 LKA 1601 0.8 2.6 0.11 32 9 16 8.8 560 2980 79
4)
555 M3GM 400 LKB 1777 0.8 2.6 0.11 35 9 14 8.4 620 3220 79
4)
630 M3GM 450 LA 2015 0.7 2.7 0.09 39 10 20 13.5 700 4030 82
4)
700 M3GM 450 LB 2238 0.8 2.8 0.09 43 10 20 15.0 770 4340 82
3000 r/min = 2 poles 3300 V 50 Hz
160 M3GM 315 LKA 513 0.9 2.8 0.14 12 8 16 1.9 210 1180 78
200
250
310
4)
4)
4)
M3GM
M3GM
M3GM
355 LKA
355 LKB
355 LKC
641
803
995
0.8
0.9
1.1
2.7
2.6
2.7
0.13
0.13
0.14
15
18
22
10
9
7
20
16
15
2.9
3.2
4.5
280
300
390
1670
1770
2140
78
78
78
3
4)
330 M3GM 355 LKD 1059 1.1 2.7 0.13 23 7 13 4.2 420 2250 78
4)
355 M3GM 400 LA 1138 0.9 2.6 0.13 24 9 20 6.9 460 2430 79
4)
400 M3GM 400 LB 1283 1.0 2.5 0.13 27 9 20 8.0 520 2650 79
4)
435 M3GM 400 LC 1395 1.1 2.5 0.14 29 8 16 7.8 580 2900 79
4)
500 M3GM 400 LKA 1601 0.8 2.5 0.11 32 10 16 9.4 590 3090 79
4)
555 M3GM 400 LKB 1777 0.8 2.6 0.11 35 9 14 8.4 620 3210 79
4)
630 M3GM 450 LA 2015 0.7 2.8 0.09 39 10 20 13.5 700 4030 82
4)
700 M3GM 450 LB 2239 0.8 2.7 0.09 43 10 20 15.0 770 4330 82
3000 r/min = 2 poles 6000 V 50 Hz
4)
250 M3GM 355 LKA 803 1.0 2.5 0.14 18 9 16 4.2 370 2010 78
4)
280 M3GM 355 LKB 897 0.9 2.6 0.13 20 9 18 4.1 350 2000 78
4)
300 M3GM 355 LKC 961 0.9 2.6 0.13 21 9 18 4.4 370 2090 78
4)
315 M3GM 400 LA 1009 0.9 2.7 0.14 22 9 20 6.4 430 2260 79
4)
355 M3GM 400 LB 1138 1.0 2.6 0.14 24 9 20 7.5 490 2510 79
4)
390 M3GM 400 LC 1250 1.0 2.6 0.14 26 8 17 6.7 520 2630 79
4)
410 M3GM 400 LD 1314 1.1 2.6 0.14 28 8 17 7.5 570 2810 79
4)
450 M3GM 400 LKA 1441 0.8 2.6 0.12 30 10 16 8.3 530 2820 79
4)
500 M3GM 400 LKB 1600 0.8 2.7 0.12 32 9 16 9.4 590 3050 79
4)
530 M3GM 400 LKC 1696 0.9 2.7 0.12 34 9 16 9.9 620 3170 79
4)
560 M3GM 450 LA 1791 0.7 2.7 0.09 36 12 20 12.3 650 3760 82
4)
630 M3GM 450 LB 2015 0.7 2.7 0.10 39 10 20 15.0 770 4250 82
4)
670 M3GM 450 LC 2142 0.8 2.7 0.10 41 10 20 15.8 800 4440 82
3000 r/min = 2 poles 6600 V 50 Hz
4)
280 M3GM 355 LKA 897 0.9 2.6 0.14 19 10 16 4.4 370 2080 78
4)
315 M3GM 400 LA 1009 1.0 2.7 0.14 22 9 20 6.4 430 2270 79
4)
355 M3GM 400 LB 1138 1.0 2.6 0.14 24 9 20 7.5 490 2500 79
4)
395 M3GM 400 LC 1266 1.1 2.6 0.14 27 8 16 6.7 520 2630 79
4)
415 M3GM 400 LD 1330 1.2 2.6 0.15 28 8 17 7.5 570 2810 79
4)
450 M3GM 400 LKA 1441 0.8 2.6 0.12 30 10 16 8.6 550 2880 79
4)
500 M3GM 400 LKB 1600 0.9 2.7 0.12 32 9 16 9.4 590 3050 79
4)
530 M3GM 400 LKC 1696 0.9 2.7 0.12 34 9 16 9.9 620 3170 79
4)
560 M3GM 450 LA 1791 0.7 2.7 0.09 36 12 20 12.7 670 3830 82
4)
630 M3GM 450 LB 2014 0.7 2.7 0.09 39 11 20 14.6 750 4200 82
4)
670 M3GM 450 LC 2143 0.7 2.6 0.09 41 10 20 15.8 800 4440 82
1)
315LK, 355LK, 400L: The given values of load inertia assume two starts from the rated torque at the rated speed and at rated voltage.
cold and one start from warm conditions in succession against quadratic load 400LK, 450L: Starting time with given values of the load inertia from cold
torque with 90% of the rated torque at the rated speed and at 80% of the rated condition in succession against quadratic load torque with 85% of the rated
voltage. torque at the rated speed and at rated voltage.
400LK, 450L: The given values of load inertia assume two starts from cold and 3)
The sound pressure levels are presented at no-load. The magnetic noise
one start from warm conditions in succession against quadratic load torque level of 2- and 4-pole motors is typically low compared to the fan noise,
with 85% of the rated torque at the rated speed and at 80% of the resulting no increase in the noise level on-load.
rated voltage. The variation and measuring tolerance of the gures is +3 dB(A).
To check validity against other starting requirements, contact ABB. 4)
Unidirectional fan construction as standard. Direction of rotation must be
2)
315LK, 355LK, 400L: Starting time with given values of the load inertia from stated when ordering, see variant codes 044 and 045.
cold condition in succession against quadratic load torque with 90% of

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 33


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 40C
Efciency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A
1500 r/min = 4 poles 3000 V 50 Hz
110 M3GM 315 LKA 3GGM  s1! 1488 94.6 94.3 0.84 0.80 27 6.2 10
132 M3GM 315 LKB 3GGM  s1! 1484 94.6 94.6 0.85 0.83 32 5.3 10
160 M3GM 315 LKC 3GGM  s1! 1485 94.9 94.8 0.87 0.85 37 6.2 11
200 M3GM 315 LKD 3GGM  s1! 1485 95.1 95.2 0.87 0.85 46 6.0 14
250 M3GM 355 LKA 3GGM  s1! 1490 95.6 95.4 0.84 0.80 60 6.2 22
315 M3GM 355 LKB 3GGM  s1! 1489 95.8 95.8 0.84 0.82 75 6.0 25
355 M3GM 355 LKC 3GGM  s1! 1488 96.0 96.0 0.85 0.82 84 6.0 27
400 M3GM 355 LKD 3GGM  s1! 1489 96.3 96.2 0.86 0.84 93 5.8 29
450 M3GM 400 LA 3GGM  s1! 1490 96.7 96.7 0.86 0.84 105 6.4 32
490 M3GM 400 LB 3GGM  s1! 1489 96.4 96.4 0.85 0.83 115 6.4 35
560 M3GM 400 LKA 3GGM  s1! 1491 96.7 96.6 0.85 0.83 131 6.0 43
600 M3GM 400 LKB 3GGM  s1! 1491 96.8 96.7 0.85 0.82 140 6.4 48
710 M3GM 450 LA 3GGM  s1! 1493 96.9 96.8 0.88 0.86 161 6.4 44
735 M3GM 450 LB 3GGM  s1! 1492 96.9 96.9 0.88 0.86 166 6.2 44
1500 r/min = 4 poles 3300 V 50 Hz
132 M3GM 315 LKA 3GGM  s2! 1488 94.8 94.6 0.82 0.77 30 6.2 13

3 160
200
250
M3GM
M3GM
M3GM
315 LKB
315 LKC
355 LKA
3GGM
3GGM
3GGM
 s2!
 s2!
 s2!
1484
1485
1489
95.0
95.1
95.6
95.0
95.1
95.4
0.84
0.87
0.84
0.82
0.85
0.81
35
42
55
5.5
6.1
6.0
12
13
19
315 M3GM 355 LKB 3GGM  s2! 1490 95.7 95.6 0.83 0.80 69 6.4 26
355 M3GM 355 LKC 3GGM  s2! 1489 96.0 95.9 0.84 0.81 77 6.4 27
400 M3GM 355 LKD 3GGM  s2! 1490 96.2 96.1 0.86 0.83 85 6.0 28
440 M3GM 400 LA 3GGM  s2! 1489 96.7 96.7 0.85 0.84 93 6.2 28
495 M3GM 400 LB 3GGM  s2! 1490 96.4 96.4 0.85 0.83 106 6.5 34
560 M3GM 400 LKA 3GGM  s2! 1491 96.7 96.6 0.85 0.83 119 6.0 39
600 M3GM 400 LKB 3GGM  s2! 1491 96.8 96.7 0.85 0.83 127 6.3 43
630 M3GM 450 LA 3GGM  s2! 1493 96.8 96.6 0.88 0.86 130 6.3 36
710 M3GM 450 LB 3GGM  s2! 1492 96.9 96.8 0.88 0.86 146 6.3 39
1500 r/min = 4 poles 6000 V 50 Hz
250 M3GM 355 LKA 3GGM  s4! 1486 95.5 95.5 0.84 0.81 30 5.8 10
315 M3GM 355 LKB 3GGM  s4! 1489 96.0 95.9 0.83 0.79 38 6.4 15
355 M3GM 400 LA 3GGM  s4! 1489 96.2 96.2 0.85 0.84 42 6.2 13
400 M3GM 400 LB 3GGM  s4! 1489 96.4 96.4 0.86 0.84 47 6.4 14
450 M3GM 400 LC 3GGM  s4! 1489 96.2 96.2 0.86 0.85 52 6.3 15
500 M3GM 400 LKA 3GGM  s4! 1491 96.5 96.4 0.85 0.83 58 5.9 19
560 M3GM 400 LKB 3GGM  s4! 1491 96.6 96.6 0.86 0.84 65 5.9 20
600 M3GM 400 LKC 3GGM  s4! 1492 96.7 96.6 0.85 0.82 70 6.4 24
630 M3GM 450 LA 3GGM  s4! 1493 96.7 96.6 0.87 0.85 72 6.5 21
710 M3GM 450 LB 3GGM  s4! 1493 96.9 96.8 0.88 0.86 80 6.4 22
1500 r/min = 4 poles 6600 V 50 Hz
250 M3GM 355 LKA 3GGM  s3! 1488 95.6 95.5 0.83 0.80 28 6.2 11
315 M3GM 355 LKB 3GGM  s3! 1487 95.9 95.9 0.84 0.81 34 6.3 12
355 M3GM 400 LA 3GGM  s3! 1489 96.2 96.2 0.86 0.84 38 6.1 11
400 M3GM 400 LB 3GGM  s3! 1489 96.3 96.4 0.86 0.84 42 6.3 13
450 M3GM 400 LC 3GGM  s3! 1489 96.3 96.2 0.86 0.84 48 6.5 14
500 M3GM 400 LKA 3GGM  s3! 1491 96.5 96.4 0.85 0.83 53 6.0 18
560 M3GM 400 LKB 3GGM  s3! 1491 96.6 96.5 0.86 0.84 59 5.9 18
600 M3GM 400 LKC 3GGM  s3! 1491 96.7 96.6 0.85 0.83 64 6.3 21
630 M3GM 450 LA 3GGM  s3! 1493 96.7 96.6 0.87 0.85 65 6.5 19
710 M3GM 450 LB 3GGM  s3! 1492 96.9 96.8 0.88 0.86 73 6.3 20

The bullet in the product code indicates choice of mounting


When ordering variant code for protection type has to be added
arrangement (see ordering information page).
to the product code according to needs:
456 Ex nA design, fullling IEC 60079-15, with certicate.
480 Ex nA II according to ATEX directive 94/9/EC, temperature
class T3.

34 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 40C
Torque Load Starting Maximum Rotor Rotor Motor Sound
TN TS Tmax Power inertia time stalling inertia weight weight pressure
1)
Output Motor type factor cold 2) time hot kgm2 kg kg level LP 3)
kW Nm TN TN cos k kgm2 s s dB(A)

1500 r/min = 4 poles 3000 V 50 Hz


110 M3GM 315 LKA 706 1.6 2.6 0.21 41 7 20 1.9 220 1180 73
132 M3GM 315 LKB 849 1.3 2.1 0.21 49 9 20 1.9 220 1180 73
160 M3GM 315 LKC 1029 1.6 2.4 0.21 58 7 16 2.8 260 1180 73
200 M3GM 315 LKD 1286 1.0 2.7 0.15 71 8 15 2.9 270 1210 73
250 M3GM 355 LKA 1603 1.3 2.5 0.17 87 8 18 5.5 400 1850 74
315 M3GM 355 LKB 2021 1.3 2.4 0.17 107 8 16 6.3 450 1980 74
355 M3GM 355 LKC 2278 1.4 2.3 0.17 119 8 14 6.8 480 2080 74
400 M3GM 355 LKD 2565 0.9 2.4 0.13 132 9 16 8.1 540 2260 74
450 M3GM 400 LA 2885 1.5 2.3 0.16 147 7 12 12.1 660 2870 74
490 M3GM 400 LB 3141 1.5 2.3 0.16 158 7 12 12.1 660 2860 79
560 M3GM 400 LKA 3587 1.0 2.5 0.12 177 9 14 13.7 730 3200 79
600 M3GM 400 LKB 3842 1.1 2.7 0.12 188 8 12 14.9 790 3380 79
710 M3GM 450 LA 4542 0.8 2.6 0.10 217 10 20 25.6 1050 4570 83
735 M3GM 450 LB 4704 0.8 2.5 0.10 224 11 22 22.9 1060 4580 83
1500 r/min = 4 poles 3300 V 50 Hz
132 M3GM 315 LKA 847 1.7 2.6 0.21 49 7 20 1.9 220 1180 73
160
200
250
M3GM
M3GM
M3GM
315 LKB
315 LKC
355 LKA
1029
1286
1603
1.4
1.0
1.3
2.2
2.7
2.4
0.21
0.15
0.17
58
71
87
8
8
8
20
15
20
2.1
2.9
5.5
240
270
400
1250
1210
1850
73
73
74
3
315 M3GM 355 LKB 2019 1.4 2.5 0.17 107 7 16 6.3 450 1970 74
355 M3GM 355 LKC 2277 1.4 2.5 0.17 119 7 14 6.8 480 2070 74
400 M3GM 355 LKD 2564 1.0 2.5 0.13 132 9 16 8.1 540 2250 74
440 M3GM 400 LA 2822 1.4 2.3 0.16 144 7 12 11.3 620 2770 74
495 M3GM 400 LB 3173 1.5 2.4 0.16 159 7 11 12.1 660 2860 79
560 M3GM 400 LKA 3587 1.0 2.5 0.12 177 9 14 13.7 730 3200 79
600 M3GM 400 LKB 3842 1.0 2.6 0.12 188 8 12 14.9 790 3370 79
630 M3GM 450 LA 4031 0.8 2.5 0.10 196 11 20 23.5 980 4340 83
710 M3GM 450 LB 4543 0.8 2.5 0.10 217 11 20 25.6 1050 4570 83
1500 r/min = 4 poles 6000 V 50 Hz
250 M3GM 355 LKA 1606 1.2 2.3 0.17 87 8 20 4.1 380 2010 74
315 M3GM 355 LKB 2021 1.1 2.7 0.14 107 8 20 4.8 420 2200 74
355 M3GM 400 LA 2277 1.4 2.3 0.17 119 7 17 10.8 600 2600 74
400 M3GM 400 LB 2565 1.5 2.4 0.17 132 7 14 11.6 640 2730 74
450 M3GM 400 LC 2887 1.5 2.3 0.17 147 7 12 12.4 670 2840 79
500 M3GM 400 LKA 3203 1.0 2.5 0.13 161 9 16 12.9 700 3050 79
560 M3GM 400 LKB 3588 1.0 2.5 0.13 177 9 14 14.1 750 3220 79
600 M3GM 400 LKC 3841 1.1 2.7 0.12 188 8 12 14.9 790 3340 79
630 M3GM 450 LA 4030 0.8 2.6 0.10 196 10 20 22.8 960 4240 83
710 M3GM 450 LB 4543 0.8 2.6 0.10 217 10 20 25.6 1050 4540 83
1500 r/min = 4 poles 6600 V 50 Hz
250 M3GM 355 LKA 1605 1.4 2.5 0.17 87 7 20 4.1 380 2010 74
315 M3GM 355 LKB 2023 1.4 2.5 0.17 107 7 20 5.0 440 2280 74
355 M3GM 400 LA 2277 1.4 2.3 0.17 119 7 17 10.8 600 2600 74
400 M3GM 400 LB 2566 1.5 2.3 0.17 132 7 14 11.6 640 2710 74
450 M3GM 400 LC 2886 1.6 2.4 0.17 147 6 12 12.4 670 2840 79
500 M3GM 400 LKA 3202 1.0 2.6 0.13 161 9 15 12.9 700 3040 79
560 M3GM 400 LKB 3588 1.0 2.5 0.13 177 9 14 14.1 750 3220 79
600 M3GM 400 LKC 3842 1.0 2.6 0.13 188 8 12 14.9 790 3330 79
630 M3GM 450 LA 4030 0.8 2.6 0.10 196 10 20 22.8 960 4230 83
710 M3GM 450 LB 4543 0.8 2.4 0.10 217 11 20 25.6 1050 4530 83

1) 3)
The given values of load inertia assume three starts from cold and two starts The sound pressure levels are presented at no-load. The magnetic noise
from warm conditions in succession against quadratic load torque with level of 2- and 4-pole motors is typically low compared to the fan noise,
90% of the rated torque at the rated speed and at 80% of the rated voltage. resulting no increase in the noise level on-load. The variation and measuring
To check validity against other starting requirements, contact ABB. tolerance of the gures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold condition in
succession against quadratic load torque with 90% of the rated torque
at the rated speed and at rated voltage.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 35


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 40C
Efciency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A
1000 r/min = 6 poles 3000 V 50 Hz
110 M3GM 315 LKA 3GGM  s1! 987 94.2 94.5 0.80 0.77 28 5.3 11
132 M3GM 315 LKB 3GGM  s1! 986 94.6 94.8 0.80 0.77 33 5.4 13
150 M3GM 315 LKC 3GGM  s1! 991 95.1 95.0 0.76 0.69 40 6.2 21
160 M3GM 355 LKA 3GGM  s1! 992 95.2 95.1 0.75 0.70 43 5.5 21
200 M3GM 355 LKB 3GGM  s1! 990 95.6 95.6 0.79 0.75 51 5.3 21
250 M3GM 355 LKC 3GGM  s1! 991 95.9 95.9 0.79 0.75 64 5.5 27
315 M3GM 400 L 3GGM  s1! 991 96.0 96.2 0.82 0.79 77 6.0 28
355 M3GM 400 LA 3GGM  s1! 991 96.2 96.3 0.82 0.80 86 5.9 30
400 M3GM 400 LB 3GGM  s1! 991 96.4 96.5 0.82 0.80 97 6.2 34
450 M3GM 400 LKA 3GGM  s1! 994 96.5 96.4 0.79 0.75 113 6.0 48
500 M3GM 400 LKB 3GGM  s1! 994 96.6 96.6 0.81 0.77 123 5.8 48
520 M3GM 400 LKC 3GGM  s1! 995 96.7 96.5 0.78 0.73 133 6.6 62
560 M3GM 450 LA 3GGM  s1! 994 96.7 96.7 0.84 0.81 133 5.9 46
630 M3GM 450 LB 3GGM  s1! 994 96.9 96.9 0.84 0.81 149 6.3 52
695 M3GM 450 LC 3GGM  s1! 995 97.0 96.9 0.84 0.81 164 6.6 60
1000 r/min = 6 poles 3300 V 50 Hz
3 112
132
150
M3GM
M3GM
M3GM
315 LKA
315 LKB
315 LKC
3GGM
3GGM
3GGM
 s2!
 s2!
 s2!
991
987
991
94.7
94.6
95.1
94.7
94.8
95.0
0.79
0.80
0.76
0.74
0.76
0.69
26
31
36
5.7
5.6
6.2
12
13
19
160 M3GM 355 LKA 3GGM  s2! 992 95.2 95.1 0.75 0.69 39 5.7 20
200 M3GM 355 LKB 3GGM  s2! 990 95.6 95.6 0.79 0.75 46 5.3 19
250 M3GM 355 LKC 3GGM  s2! 990 95.8 95.9 0.80 0.76 57 5.3 23
310 M3GM 400 L 3GGM  s2! 990 96.0 96.1 0.82 0.79 69 5.8 24
345 M3GM 400 LA 3GGM  s2! 991 96.2 96.3 0.82 0.79 77 6.2 27
390 M3GM 400 LB 3GGM  s2! 991 96.3 96.4 0.82 0.80 86 6.2 30
450 M3GM 400 LKA 3GGM  s2! 994 96.5 96.5 0.80 0.76 102 5.9 41
490 M3GM 400 LKB 3GGM  s2! 994 96.6 96.6 0.81 0.77 110 5.9 44
530 M3GM 400 LKC 3GGM  s2! 994 96.7 96.6 0.79 0.74 122 6.4 54
560 M3GM 450 LA 3GGM  s2! 994 96.7 96.7 0.84 0.82 120 6.0 41
630 M3GM 450 LB 3GGM  s2! 995 96.9 96.9 0.84 0.81 135 6.4 48
695 M3GM 450 LC 3GGM  s2! 995 97.0 96.9 0.84 0.81 150 6.6 54
1000 r/min = 6 poles 6000 V 50 Hz
220 M3GM 355 LKA 3GGM  s4! 992 95.5 95.6 0.80 0.76 28 6.3 12
250 M3GM 355 LKB 3GGM  s4! 992 95.6 95.8 0.81 0.78 31 5.7 12
280 M3GM 400 L 3GGM  s4! 991 96.0 96.0 0.80 0.76 35 5.6 14
315 M3GM 400 LA 3GGM  s4! 992 96.2 96.2 0.80 0.76 40 5.8 16
350 M3GM 400 LB 3GGM  s4! 991 96.3 96.3 0.80 0.77 44 5.7 17
400 M3GM 400 LKA 3GGM  s4! 993 96.4 96.3 0.81 0.77 50 5.5 19
450 M3GM 400 LKC 3GGM  s4! 993 96.6 96.5 0.80 0.76 56 6.0 23
500 M3GM 450 LA 3GGM  s4! 995 96.6 96.5 0.83 0.80 60 6.3 22
560 M3GM 450 LB 3GGM  s4! 995 96.7 96.7 0.84 0.81 66 6.3 23
630 M3GM 450 LC 3GGM  s4! 994 96.8 96.8 0.84 0.81 75 6.3 26
650 M3GM 450 LD 3GGM  s4! 994 96.9 96.9 0.85 0.82 76 6.4 26
1000 r/min = 6 poles 6600 V 50 Hz
250 M3GM 355 LKA 3GGM  s3! 994 95.8 95.7 0.79 0.74 29 6.5 13
280 M3GM 400 L 3GGM  s3! 991 95.9 95.9 0.79 0.75 32 5.6 13
315 M3GM 400 LA 3GGM  s3! 992 96.2 96.1 0.79 0.75 36 6.1 16
355 M3GM 400 LB 3GGM  s3! 991 96.3 96.3 0.80 0.76 40 5.8 16
400 M3GM 400 LKA 3GGM  s3! 993 96.4 96.3 0.80 0.77 45 5.7 18
450 M3GM 400 LKC 3GGM  s3! 993 96.5 96.4 0.80 0.76 51 6.0 21
500 M3GM 450 LA 3GGM  s3! 994 96.6 96.6 0.84 0.82 54 6.0 18
560 M3GM 450 LB 3GGM  s3! 994 96.7 96.7 0.85 0.82 60 6.1 20
630 M3GM 450 LC 3GGM  s3! 994 96.8 96.8 0.85 0.83 67 6.1 22

The bullet in the product code indicates choice of mounting


When ordering variant code for protection type has to be added
arrangement (see ordering information page).
to the product code according to needs:
456 Ex nA design, fullling IEC 60079-15, with certicate.
480 Ex nA II according to ATEX directive 94/9/EC, temperature
class T3.

36 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 40C
Torque Load Starting Maximum Rotor Rotor Motor Sound
TN TS Tmax Power inertia time stalling inertia weight weight pressure
1)
Output Motor type factor cold 2) time hot kgm2 kg kg level LP 3)
kW Nm TN TN cos k kgm2 s s dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


110 M3GM 315 LKA 1065 1.5 2.2 0.23 111 9 20 2.8 270 1170 65
132 M3GM 315 LKB 1278 1.6 2.3 0.22 131 8 20 3.2 290 1240 65
150 M3GM 315 LKC 1445 1.4 2.9 0.17 148 8 16 3.3 300 1270 65
160 M3GM 355 LKA 1541 1.4 2.4 0.19 157 9 20 4.6 350 1660 70
200 M3GM 355 LKB 1928 1.4 2.2 0.19 192 9 20 5.7 410 1850 70
250 M3GM 355 LKC 2410 1.5 2.2 0.19 236 8 20 6.9 480 2030 70
315 M3GM 400 L 3036 1.6 2.2 0.18 291 8 18 14.6 670 2500 75
355 M3GM 400 LA 3422 1.6 2.2 0.18 324 8 18 17.4 770 2730 75
400 M3GM 400 LB 3854 1.7 2.3 0.18 360 7 18 20.1 870 2970 75
450 M3GM 400 LKA 4323 1.2 2.5 0.14 400 9 22 17.9 870 3090 78
500 M3GM 400 LKB 4806 1.2 2.4 0.13 439 9 22 20.5 960 3330 78
520 M3GM 400 LKC 4993 1.4 2.7 0.13 455 7 21 21.1 980 3380 78
560 M3GM 450 LA 5379 1.1 2.5 0.14 486 10 20 29.2 1040 3990 78
630 M3GM 450 LB 6049 1.2 2.6 0.14 539 9 20 34.5 1190 4360 78
695 M3GM 450 LC 6673 1.3 2.6 0.14 587 8 22 34.0 1250 4510 78
1000 r/min = 6 poles 3300 V 50 Hz
112
132
150
M3GM
M3GM
M3GM
315 LKA
315 LKB
315 LKC
1080
1277
1445
1.2
1.6
1.4
2.6
2.3
2.9
0.18
0.22
0.17
113
131
148
9
8
8
20
20
16
3.0
3.2
3.3
280
290
300
1200
1240
1270
65
65
65
3
160 M3GM 355 LKA 1540 1.5 2.4 0.19 157 8 20 4.6 350 1660 70
200 M3GM 355 LKB 1928 1.4 2.2 0.19 192 9 20 5.7 410 1850 70
250 M3GM 355 LKC 2412 1.4 2.1 0.19 236 9 20 6.9 480 2030 70
310 M3GM 400 L 2989 1.5 2.2 0.18 286 8 22 13.3 680 2500 75
345 M3GM 400 LA 3324 1.7 2.3 0.18 315 7 22 16.0 780 2730 75
390 M3GM 400 LB 3758 1.7 2.3 0.18 352 7 18 20.1 870 2960 75
450 M3GM 400 LKA 4324 1.2 2.4 0.14 400 9 22 18.5 890 3160 78
490 M3GM 400 LKB 4709 1.2 2.4 0.14 432 9 22 20.5 960 3310 78
530 M3GM 400 LKC 5090 1.3 2.7 0.13 463 8 20 21.1 980 3390 78
560 M3GM 450 LA 5379 1.1 2.5 0.14 486 10 20 30.3 1070 4060 78
630 M3GM 450 LB 6049 1.2 2.6 0.14 539 9 20 34.5 1190 4360 78
695 M3GM 450 LC 6673 1.3 2.6 0.14 857 8 22 34.0 1250 4510 78
1000 r/min = 6 poles 6000 V 50 Hz
220 M3GM 355 LKA 2118 1.7 2.5 0.21 210 7 16 8.1 540 2170 70
250 M3GM 355 LKB 2406 1.0 2.4 0.16 203 9 14 8.0 530 2150 70
280 M3GM 400 L 2697 1.3 2.2 0.16 261 9 20 10.5 590 2530 75
315 M3GM 400 LA 3033 1.4 2.3 0.16 291 8 20 11.8 640 2710 75
350 M3GM 400 LB 3372 1.4 2.2 0.16 319 8 20 12.7 680 2830 75
400 M3GM 400 LKA 3848 0.9 2.4 0.11 360 11 22 11.9 730 3090 78
450 M3GM 400 LKC 4326 1.0 2.6 0.11 400 10 22 14.0 820 3380 78
500 M3GM 450 LA 4801 1.2 2.6 0.14 439 9 20 28.2 1010 3880 78
560 M3GM 450 LB 5377 1.2 2.6 0.14 486 9 20 32.4 1130 4180 78
630 M3GM 450 LC 6050 1.4 2.5 0.16 539 7 20 37.2 1260 4480 78
650 M3GM 450 LD 6242 1.2 2.6 0.14 554 9 20 36.7 1250 4480 78
1000 r/min = 6 poles 6600 V 50 Hz
250 M3GM 355 LKA 2403 1.3 2.8 0.16 236 8 13 8.3 540 2200 70
280 M3GM 400 L 2697 1.3 2.2 0.17 261 9 20 10.1 570 2470 75
315 M3GM 400 LA 3031 1.5 2.4 0.16 291 8 20 11.8 640 2710 75
355 M3GM 400 LB 3419 1.4 2.3 0.16 324 8 20 12.7 680 2830 75
400 M3GM 400 LKA 3847 0.9 2.4 0.11 360 11 22 11.9 730 3090 78
450 M3GM 400 LKC 4326 1.0 2.6 0.11 400 10 22 14.0 820 3380 78
500 M3GM 450 LA 4802 1.1 2.5 0.14 439 10 20 29.2 1040 3950 78
560 M3GM 450 LB 5379 1.1 2.5 0.14 486 9 20 32.4 1130 4170 78
630 M3GM 450 LC 6051 1.2 2.5 0.14 539 9 20 36.7 1250 4470 78

1) 3)
The given values of load inertia assume three starts from cold and two starts The sound pressure levels are presented at no-load. Sound level values
from warm conditions in succession against quadratic load torque with of 68-pole motors at no-load are typically 1...3 dB(A) higher than
90% of the rated torque at the rated speed and at 80% of the rated voltage. the corresponding values at no-load. The variation and measuring tolerance
To check validity against other starting requirements, contact ABB. of the gures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold condition in
succession against quadratic load torque with 90% of the rated torque
at the rated speed and at rated voltage.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 37


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 40C
Efciency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A
750 r/min = 8 poles 3000 V 50 Hz
200 M3GM 400 LA 3GGM  s1! 742 94.9 95.1 0.79 0.76 51 5.2 21
220 M3GM 400 LB 3GGM  s1! 742 95.1 95.2 0.79 0.75 56 5.5 24
250 M3GM 400 LC 3GGM  s1! 742 95.3 95.5 0.80 0.77 63 5.4 25
270 M3GM 400 LD 3GGM  s1! 741 95.3 95.5 0.80 0.77 68 5.4 26
290 M3GM 400 LE 3GGM  s1! 741 95.5 95.7 0.80 0.77 73 5.5 29
315 M3GM 400 LKA 3GGM  s1! 744 95.7 95.7 0.78 0.73 82 5.2 37
355 M3GM 400 LKB 3GGM  s1! 744 95.9 95.9 0.78 0.74 91 5.1 39
370 M3GM 400 LKC 3GGM  s1! 745 96.0 95.9 0.76 0.71 97 5.6 47
400 M3GM 450 LA 3GGM  s1! 746 96.3 96.1 0.78 0.74 102 5.8 46
450 M3GM 450 LB 3GGM  s1! 746 96.4 96.2 0.78 0.73 115 6.0 53
500 M3GM 450 LC 3GGM  s1! 746 96.5 96.3 0.78 0.74 127 6.0 58
530 M3GM 450 LD 3GGM  s1! 746 96.5 96.3 0.78 0.73 135 6.1 61
750 r/min = 8 poles 3300 V 50 Hz
200 M3GM 400 LA 3GGM  s2! 742 94.9 95.1 0.79 0.76 46 5.1 18
220 M3GM 400 LB 3GGM  s2! 742 95.1 95.2 0.80 0.76 51 5.2 20
250 M3GM 400 LC 3GGM  s2! 741 95.2 95.5 0.80 0.78 57 5.0 21

3 280
290
315
M3GM
M3GM
M3GM
400 LD
400 LE
400 LKA
3GGM
3GGM
3GGM
 s2!
 s2!
 s2!
741
742
744
95.4
95.4
95.8
95.6
95.6
95.8
0.80
0.80
0.77
0.77
0.76
0.72
64
67
74
5.4
5.7
5.3
25
27
34
345 M3GM 400 LKB 3GGM  s2! 744 95.8 95.8 0.78 0.74 81 5.2 36
375 M3GM 400 LKC 3GGM  s2! 744 96.0 95.9 0.77 0.72 89 5.5 42
400 M3GM 450 LA 3GGM  s2! 745 96.3 96.1 0.78 0.74 93 5.8 42
450 M3GM 450 LB 3GGM  s2! 745 96.3 96.2 0.78 0.73 104 5.9 47
500 M3GM 450 LC 3GGM  s2! 745 96.5 96.3 0.79 0.75 114 5.8 49
530 M3GM 450 LD 3GGM  s2! 745 96.4 96.3 0.80 0.75 121 5.8 52
750 r/min = 8 poles 6000 V 50 Hz
160 M3GM 400 LA 3GGM  s4! 741 94.4 94.4 0.76 0.71 21 5.2 10
180 M3GM 400 LB 3GGM  s4! 740 94.5 94.6 0.77 0.72 24 5.0 11
200 M3GM 400 LC 3GGM  s4! 740 94.8 94.8 0.77 0.73 26 5.1 12
220 M3GM 400 LD 3GGM  s4! 740 94.8 95.0 0.78 0.74 29 4.9 12
250 M3GM 400 LE 3GGM  s4! 740 95.1 95.1 0.77 0.72 33 5.3 15
280 M3GM 400 LKA 3GGM  s4! 743 95.6 95.6 0.77 0.72 37 5.3 17
315 M3GM 400 LKB 3GGM  s4! 743 95.7 95.6 0.76 0.71 42 5.4 20
355 M3GM 450 LA 3GGM  s4! 746 96.0 95.8 0.78 0.74 45 5.8 20
400 M3GM 450 LB 3GGM  s4! 746 96.1 96.0 0.78 0.74 51 5.8 23
450 M3GM 450 LC 3GGM  s4! 745 96.2 96.2 0.80 0.76 56 5.6 24
500 M3GM 450 LD 3GGM  s4! 745 96.4 96.3 0.80 0.76 62 5.7 26
750 r/min = 8 poles 6600 V 50 Hz
160 M3GM 400 LA 3GGM  s3! 741 94.5 94.4 0.76 0.71 20 5.3 9
180 M3GM 400 LB 3GGM  s3! 741 94.6 94.5 0.76 0.70 22 5.3 11
200 M3GM 400 LC 3GGM  s3! 739 94.6 94.8 0.78 0.74 24 4.8 10
220 M3GM 400 LD 3GGM  s3! 740 94.9 94.9 0.77 0.72 26 5.2 12
250 M3GM 400 LE 3GGM  s3! 741 95.1 95.1 0.76 0.71 30 5.4 14
280 M3GM 400 LKA 3GGM  s3! 743 95.6 95.5 0.76 0.71 34 5.4 16
315 M3GM 400 LKB 3GGM  s3! 743 95.6 95.6 0.76 0.71 38 5.4 18
355 M3GM 450 LA 3GGM  s3! 745 96.0 95.9 0.79 0.75 41 5.7 18
400 M3GM 450 LB 3GGM  s3! 745 96.1 96.0 0.80 0.75 46 5.6 19
450 M3GM 450 LC 3GGM  s3! 745 96.2 96.2 0.80 0.76 51 5.5 21
500 M3GM 450 LD 3GGM  s3! 745 96.3 96.3 0.81 0.77 56 5.5 22

The bullet in the product code indicates choice of mounting


When ordering variant code for protection type has to be added
arrangement (see ordering information page).
to the product code according to needs:
456 Ex nA design, fullling IEC 60079-15, with certicate.
480 Ex nA II according to ATEX directive 94/9/EC, temperature
class T3.

38 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 40C
Torque Load Starting Maximum Rotor Rotor Motor Sound
TN TS Tmax Power inertia time stalling inertia weight weight pressure
1)
Output Motor type factor cold 2) time hot kgm2 kg kg level LP 3)
kW Nm TN TN cos k kgm2 s s dB(A)

750 r/min = 8 poles 3000 V 50 Hz


200 M3GM 400 LA 2575 1.0 2.4 0.15 388 11 22 13.6 630 2370 75
220 M3GM 400 LB 2831 1.1 2.5 0.15 423 10 22 15.0 680 2490 75
250 M3GM 400 LC 3219 1.1 2.4 0.14 476 10 22 17.7 780 2730 75
270 M3GM 400 LD 3479 1.1 2.4 0.15 510 10 22 19.1 830 2830 75
290 M3GM 400 LE 3736 1.1 2.4 0.14 545 9 22 20.5 870 2960 75
315 M3GM 400 LKA 4041 1.2 2.1 0.18 587 11 20 20.0 880 3080 75
355 M3GM 400 LKB 4557 1.1 2.1 0.17 655 12 20 22.0 950 3270 75
370 M3GM 400 LKC 4745 1.3 2.3 0.18 680 10 22 21.8 1000 3380 75
400 M3GM 450 LA 5124 1.1 2.4 0.14 730 11 20 30.8 1080 4050 76
450 M3GM 450 LB 5763 1.2 2.5 0.14 811 10 20 33.0 1140 4200 76
500 M3GM 450 LC 6404 1.2 2.5 0.14 892 10 20 37.3 1260 4500 76
530 M3GM 450 LD 6787 1.2 2.6 0.14 940 10 20 39.5 1330 4620 76
750 r/min = 8 poles 3300 V 50 Hz
200 M3GM 400 LA 2576 1.0 2.3 0.15 388 11 22 13.6 630 2370 75
220 M3GM 400 LB 2833 1.0 2.4 0.15 423 10 22 15.0 680 2490 75
250 M3GM 400 LC 3224 1.0 2.2 0.15 476 11 22 17.7 780 2720 75
280
290
315
M3GM
M3GM
M3GM
400 LD
400 LE
400 LKA
3607
3734
4041
1.1
1.2
1.2
2.4
2.5
2.2
0.14
0.15
0.17
528
545
587
10
9
11
22
22
20
19.1
20.5
20.0
830
870
880
2840
2950
3100
75
75
75
3
345 M3GM 400 LKB 4428 1.2 2.2 0.18 638 11 22 20.5 950 3260 75
375 M3GM 400 LKC 4811 1.3 2.3 0.17 688 10 20 23.3 990 3390 75
400 M3GM 450 LA 5124 1.1 2.4 0.14 730 11 20 30.8 1080 4040 76
450 M3GM 450 LB 5764 1.1 2.5 0.14 811 10 20 33.0 1140 4190 76
500 M3GM 450 LC 6406 1.1 2.4 0.14 892 11 20 37.3 1260 4490 76
530 M3GM 450 LD 6790 1.1 2.4 0.14 940 11 20 39.5 1330 4620 76
750 r/min = 8 poles 6000 V 50 Hz
160 M3GM 400 LA 2062 1.1 2.5 0.16 315 10 22 10.2 560 2400 75
180 M3GM 400 LB 2322 1.0 2.4 0.16 352 11 22 10.7 580 2460 75
200 M3GM 400 LC 2580 1.1 2.4 0.15 388 10 22 12.1 640 2640 75
220 M3GM 400 LD 2840 1.0 2.3 0.15 423 10 22 13.0 680 2760 75
250 M3GM 400 LE 3225 1.1 2.5 0.15 476 9 22 14.4 740 2930 75
280 M3GM 400 LKA 3597 1.0 2.4 0.13 528 11 20 15.0 790 3240 75
315 M3GM 400 LKB 4047 1.0 2.5 0.13 587 10 20 15.9 830 3350 75
355 M3GM 450 LA 4547 1.1 2.4 0.15 655 11 20 28.6 1020 3850 76
400 M3GM 450 LB 5124 1.1 2.4 0.15 730 10 20 30.8 1080 4000 76
450 M3GM 450 LC 5766 1.1 2.3 0.15 811 11 20 35.2 1200 4300 76
500 M3GM 450 LD 6406 1.1 2.3 0.15 892 11 20 39.5 1330 4600 76
750 r/min = 8 poles 6600 V 50 Hz
160 M3GM 400 LA 2061 1.1 2.6 0.16 315 10 22 10.7 580 2450 75
180 M3GM 400 LB 2319 1.1 2.6 0.16 352 10 22 10.7 580 2460 75
200 M3GM 400 LC 2583 1.0 2.2 0.15 388 11 22 12.1 640 2630 75
220 M3GM 400 LD 2838 1.1 2.4 0.15 423 10 22 13.0 680 2750 75
250 M3GM 400 LE 3223 1.2 2.6 0.15 476 9 22 14.4 740 2930 75
280 M3GM 400 LKA 3596 1.0 2.5 0.13 528 10 20 15.0 790 3230 75
315 M3GM 400 LKB 4047 1.0 2.5 0.13 587 10 20 15.9 830 3350 75
355 M3GM 450 LA 4548 1.1 2.4 0.15 655 12 20 29.7 1050 3920 76
400 M3GM 450 LB 5125 1.1 2.3 0.15 730 11 20 31.9 1110 4070 76
450 M3GM 450 LC 5767 1.1 2.3 0.15 811 12 20 35.2 1200 4300 76
500 M3GM 450 LD 6408 1.0 2.2 0.15 892 12 20 39.5 1330 4590 76

1) 3)
The given values of load inertia assume three starts from cold and two starts The sound pressure levels are presented at no-load. Sound level values
from warm conditions in succession against quadratic load torque with of 68-pole motors at no-load are typically 1...3 dB(A) higher than the
90% of the rated torque at the rated speed and at 80% of the rated voltage. corresponding values at no-load. The variation and measuring tolerance of
To check validity against other starting requirements, contact ABB. the gures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold condition in
succession against quadratic load torque with 90% of the rated torque
at the rated speed and at rated voltage.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 39


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 50C
Efciency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

3000 r/min = 2 poles 3300 V 50 Hz


4)
180 M3GM 355 LKA 3GGM  s2" 2979 94.7 94.5 0.90 0.90 37 5.3 7
4)
200 M3GM 355 LKB 3GGM  s2" 2980 95.2 95.0 0.91 0.91 41 5.3 7
4)
224 M3GM 355 LKC 3GGM  s2" 2980 95.4 95.3 0.91 0.92 45 5.4 7
4)
250 M3GM 355 LKD 3GGM  s2" 2980 95.7 95.6 0.91 0.92 50 5.4 8
4)
265 M3GM 355 LKE 3GGM  s2" 2978 95.7 95.7 0.91 0.92 53 5.3 8
4)
280 M3GM 400 LKA 3GGM  s2" 2981 95.7 95.5 0.91 0.91 57 5.3 10
4)
315 M3GM 400 LKB 3GGM  s2" 2982 95.9 95.8 0.90 0.90 64 5.3 12
4)
355 M3GM 400 LKC 3GGM  s2" 2983 96.2 96.1 0.91 0.91 71 5.4 12
4)
400 M3GM 400 LKD 3GGM  s2" 2983 96.4 96.4 0.92 0.92 79 5.4 11
4)
450 M3GM 400 LKE 3GGM  s2" 2982 96.5 96.6 0.92 0.93 89 5.3 12
4)
500 M3GM 450 LA 3GGM  s2" 2984 96.7 96.6 0.90 0.91 101 5.3 16
4)
560 M3GM 450 LB 3GGM  s2" 2985 96.8 96.7 0.90 0.91 112 5.4 18

3 3000 r/min = 2 poles


224 4)
M3GM 400 LKA 3GGM  s3"
6600 V 50 Hz
2982 95.2 94.9 0.88 0.88 23 5.4 5
4)
250 M3GM 400 LKB 3GGM  s3" 2982 95.3 95.1 0.88 0.88 26 5.4 5
4)
280 M3GM 400 LKC 3GGM  s3" 2982 95.5 95.4 0.91 0.91 28 5.4 5
4)
315 M3GM 400 LKD 3GGM  s3" 2982 95.6 95.6 0.91 0.91 32 5.4 5
4)
355 M3GM 400 LKE 3GGM  s3" 2982 95.9 96.0 0.91 0.92 36 5.4 5
4)
400 M3GM 400 LKF 3GGM  s3" 2982 96.2 96.3 0.91 0.92 40 5.4 6
4)
450 M3GM 450 LA 3GGM  s3" 2985 96.4 96.3 0.90 0.91 45 5.3 8
4)
500 M3GM 450 LB 3GGM  s3" 2984 96.6 96.5 0.90 0.91 50 5.3 8

The bullet in the product code indicates choice of mounting


When ordering variant code for protection type has to be added
arrangement (see ordering information page).
to the product code according to needs:
456 Ex nA design, fullling IEC 60079-15, with certicate.
480 Ex nA II according to ATEX directive 94/9/EC, temperature
class T3.

40 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 50C
Torque Load Starting Maximum Rotor Rotor Motor Sound
TN TS Tmax Power inertia time stalling inertia weight weight pressure
1)
Output Motor type factor cold 2) time hot kgm2 kg kg level LP 3)
kW Nm TN TN cos k kgm2 s s dB(A)

3000 r/min = 2 poles 3300 V 50 Hz


4)
180 M3GM 355 LKA 577 0.5 2.5 0.11 13 15 20 3.1 290 1750 78
4)
200 M3GM 355 LKB 641 0.6 2.5 0.11 15 14 20 3.9 340 1980 78
4)
224 M3GM 355 LKC 718 0.6 2.5 0.11 16 14 20 4.2 360 2070 78
4)
250 M3GM 355 LKD 801 0.6 2.5 0.11 18 13 20 4.6 390 2210 78
4)
265 M3GM 355 LKE 850 0.6 2.4 0.11 19 13 20 4.6 390 2210 78
4)
280 M3GM 400 LKA 897 0.4 2.5 0.09 20 19 25 5.6 430 2440 79
4)
315 M3GM 400 LKB 1009 0.5 2.5 0.09 22 17 25 6.0 440 2500 79
4)
355 M3GM 400 LKC 1137 0.5 2.5 0.09 24 16 25 7.6 500 2740 79
4)
400 M3GM 400 LKD 1281 0.5 2.5 0.10 27 15 20 10.0 570 3090 79
4)
450 M3GM 400 LKE 1441 0.6 2.4 0.10 30 14 20 10.8 600 3190 79
4)
500 M3GM 450 LA 1600 0.8 2.3 0.11 32 12 20 16.8 780 4400 82
4)
560 M3GM 450 LB 1792 0.8 2.3 0.11 36 11 20 18.0 820 4560 82

3000 r/min = 2 poles


224 4)
M3GM 400 LKA 717 0.8 2.4
3300 V 50 Hz
0.13 16 12 20 6.4 480 2530 79
3
4)
250 M3GM 400 LKB 801 0.8 2.4 0.12 18 11 20 6.4 480 2530 79
4)
280 M3GM 400 LKC 897 0.5 2.5 0.10 20 17 25 6.7 460 2510 79
4)
315 M3GM 400 LKD 1009 0.5 2.4 0.10 19 15 20 6.7 460 2510 79
4)
355 M3GM 400 LKE 1137 0.5 2.4 0.10 23 15 20 7.7 510 2740 79
4)
400 M3GM 400 LKF 1281 0.5 2.4 0.10 27 15 20 10.4 580 3090 79
4)
450 M3GM 450 LA 1440 0.7 2.3 0.11 30 13 20 15.0 740 4130 82
4)
500 M3GM 450 LB 1600 0.7 2.3 0.11 32 12 20 16.8 780 4360 82

1)
355LK: The given values of load inertia assume two starts from cold and one 400LK, 450L: Starting time with given values of the load inertia from cold
start from warm conditions in succession against quadratic load torque with condition in succession against quadratic load torque with 70% of the rated
75% of the rated torque at the rated speed and at 80% of the rated voltage. torque at the rated speed and at rated voltage.
3)
400LK, 450L: The given values of load inertia assume two starts from cold and The sound pressure levels are presented at no-load. The magnetic noise
one start from warm conditions in succession against quadratic load torque level of 2- and 4-pole motors is typically low compared to the fan noise,
with 70% of the rated torque at the rated speed and at 80% of the resulting no increase in the noise level on-load. The variation and measuring
rated voltage. tolerance of the gures is +3 dB(A).
4)
To check validity against other starting requirements, contact ABB. Unidirectional fan construction as standard. Direction of rotation must be
2)
355LK: Starting time with given values of the load inertia from cold condition stated when ordering, see variant codes 044 and 045.
in succession against quadratic load torque with 75% of the rated torque
at the rated speed and at rated voltage.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 41


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 50C
Efciency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

1500 r/min = 4 poles 3300 V 50 Hz


132 M3GM 315 LKA 3GGM  s2" 1486 94.7 94.6 0.85 0.83 29 5.2 10
140 M3GM 315 LKB 3GGM  s2" 1486 94.8 94.8 0.85 0.83 30 5.4 10
155 M3GM 315 LKC 3GGM  s2" 1485 95.0 95.0 0.85 0.83 33 5.3 11
180 M3GM 355 LKA 3GGM  s2" 1490 95.1 94.8 0.83 0.79 40 5.4 15
200 M3GM 355 LKB 3GGM  s2" 1490 95.4 95.1 0.84 0.81 44 5.3 15
224 M3GM 355 LKC 3GGM  s2" 1490 95.6 95.4 0.84 0.82 49 5.2 16
250 M3GM 355 LKD 3GGM  s2" 1490 95.8 95.6 0.84 0.82 54 5.4 18
280 M3GM 355 LKE 3GGM  s2" 1490 95.8 95.7 0.85 0.82 61 5.2 20
315 M3GM 355 LKF 3GGM  s2" 1490 96.0 95.9 0.85 0.83 68 5.3 22
335 M3GM 355 LKG 3GGM  s2" 1490 96.2 96.1 0.85 0.83 72 5.4 23
355 M3GM 400 LKA 3GGM  s2" 1489 96.1 96.0 0.85 0.83 76 5.0 23
400 M3GM 400 LKB 3GGM  s2" 1490 96.3 96.2 0.85 0.83 86 5.2 27

3 450
500
560
M3GM
M3GM
M3GM
400 LKC
400 LKD
450 LA
3GGM
3GGM
3GGM
 s2"
 s2"
 s2"
1490
1490
1491
96.5
96.7
96.6
96.5
96.6
96.5
0.86
0.86
0.86
0.84
0.85
0.86
95
105
117
5.3
5.4
5.4
28
29
31
600 M3GM 450 LB 3GGM  s2" 1491 96.7 96.6 0.87 0.86 125 5.4 32

1500 r/min = 4 poles 6600 V 50 Hz


224 M3GM 355 LKA 3GGM  s3" 1487 95.5 95.4 0.84 0.82 24 5.3 8
250 M3GM 355 LKB 3GGM  s3" 1487 95.7 95.6 0.85 0.82 27 5.4 9
280 M3GM 400 LKA 3GGM  s3" 1491 95.5 95.2 0.84 0.81 31 5.4 11
315 M3GM 400 LKB 3GGM  s3" 1491 95.6 95.6 0.85 0.82 34 5.3 11
355 M3GM 400 LKC 3GGM  s3" 1490 96.1 96.0 0.86 0.85 37 5.3 10
400 M3GM 400 LKD 3GGM  s3" 1491 96.3 96.3 0.87 0.85 42 5.4 12
450 M3GM 400 LKE 3GGM  s3" 1490 96.4 96.4 0.87 0.86 47 5.3 13
500 M3GM 450 LA 3GGM  s3" 1491 96.4 96.3 0.86 0.85 53 5.4 14
560 M3GM 450 LB 3GGM  s3" 1491 96.6 96.4 0.86 0.85 59 5.4 16

The bullet in the product code indicates choice of mounting


When ordering variant code for protection type has to be added
arrangement (see ordering information page).
to the product code according to needs:
456 Ex nA design, fullling IEC 60079-15, with certicate.
480 Ex nA II according to ATEX directive 94/9/EC, temperature
class T3.

42 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 50C
Torque Load Starting Maximum Rotor Rotor Motor Sound
TN TS Tmax Power inertia time stalling inertia weight weight pressure
1)
Output Motor type factor cold 2) time hot kgm2 kg kg level LP 3)
kW Nm TN TN cos k kgm2 s s dB(A)

1500 r/min = 4 poles 3300 V 50 Hz


132 M3GM 315 LKA 848 0.8 2.4 0.15 49 11 20 1.9 220 1180 73
140 M3GM 315 LKB 900 0.8 2.5 0.15 52 11 20 2.0 230 1210 73
155 M3GM 315 LKC 997 0.8 2.4 0.15 57 11 20 2.1 240 1250 73
180 M3GM 355 LKA 1153 0.9 2.4 0.15 65 11 20 5.0 370 1750 74
200 M3GM 355 LKB 1282 0.9 2.3 0.15 71 11 20 5.5 400 1840 74
224 M3GM 355 LKC 1435 0.9 2.3 0.15 79 11 20 6.1 430 1940 74
250 M3GM 355 LKD 1602 1.0 2.3 0.15 87 10 20 6.7 460 2030 74
280 M3GM 355 LKE 1795 0.9 2.2 0.15 97 11 20 6.9 470 2060 74
315 M3GM 355 LKF 2019 1.0 2.3 0.15 107 10 20 7.8 520 2200 74
335 M3GM 355 LKG 2147 1.0 2.3 0.15 113 10 20 8.3 550 2300 74
355 M3GM 400 LKA 2277 0.7 2.2 0.11 119 13 20 9.6 560 2670 79
400 M3GM 400 LKB 2564 0.7 2.3 0.11 132 12 18 12.0 600 2790 79
450
500
560
M3GM
M3GM
M3GM
400 LKC
400 LKD
450 LA
2884
3204
3586
0.7
0.7
1.0
2.3
2.3
2.3
0.11
0.11
0.13
147
161
177
12
11
10
18
18
20
14.4
18.0
23.5
660
760
970
3020
3350
4280
79
79
83
3
600 M3GM 450 LB 3843 1.0 2.2 0.13 188 10 20 30.7 1070 4570 83

1500 r/min = 4 poles 3300 V 50 Hz


224 M3GM 355 LKA 1438 1.1 2.3 0.16 79 9 20 4.8 390 2050 74
250 M3GM 355 LKB 1606 1.1 2.3 0.16 87 9 20 5.5 420 2190 74
280 M3GM 400 LKA 1793 1.0 2.4 0.15 97 10 20 10.2 560 2560 79
315 M3GM 400 LKB 2018 0.7 2.3 0.12 107 14 20 9.6 560 2600 79
355 M3GM 400 LKC 2275 0.7 2.3 0.12 119 13 20 13.8 650 2900 79
400 M3GM 400 LKD 2562 0.7 2.3 0.11 132 12 20 16.2 710 3130 79
450 M3GM 400 LKE 2884 0.7 2.3 0.11 147 12 20 17.4 750 3240 79
500 M3GM 450 LA 3202 1.1 2.2 0.15 161 9 20 28.6 1030 4390 83
560 M3GM 450 LB 3586 1.1 2.2 0.15 177 9 20 30.7 1080 4550 83

1)
315LK: The given values of load inertia assume three starts from cold and two in succession against quadratic load torque with 90% of the rated torque at
starts from warm conditions in succession against quadratic load torque with the rated speed and at rated voltage.
90% of the rated torque at the rated speed and at 80% of the rated voltage. 355LK: Starting time with given values of the load inertia from cold condition
355LK: The given values of load inertia assume two starts from cold and one in succession against quadratic load torque with 80% of the rated torque at
start from warm conditions in succession against quadratic load torque with the rated speed and at rated voltage.
80% of the rated torque at the rated speed and at 80% of the rated voltage. 400LK, 450L: Starting time with given values of the load inertia from cold
400LK, 450L: The given values of load inertia assume two starts from cold and condition in succession against quadratic load torque with 75% of the rated
one start from warm conditions in succession against quadratic load torque torque at the rated speed and at rated voltage.
with 75% of the rated torque at the rated speed and at 80% of the 3)
The sound pressure levels are presented at no-load. The magnetic noise
rated voltage. level of 2- and 4-pole motors is typically low compared to the fan noise,
To check validity against other starting requirements, contact ABB. resulting no increase in the noise level on-load. The variation and measuring
2)
315LK: Starting time with given values of the load inertia from cold condition tolerance of the gures is +3 dB(A).

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 43


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 50C
Efciency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

1000 r/min = 6 poles 3300 V 50 Hz


112 M3GM 315 LKA 3GGM  s2" 990 94.7 94.8 0.79 0.75 26 5.1 11
125 M3GM 315 LKB 3GGM  s2" 990 94.8 95.0 0.79 0.75 29 5.1 13
132 M3GM 315 LKC 3GGM  s2" 991 95.0 95.1 0.78 0.73 31 5.3 14
140 M3GM 355 LKA 3GGM  s2" 993 95.4 95.3 0.78 0.74 33 5.0 14
160 M3GM 355 LKB 3GGM  s2" 993 95.7 95.6 0.79 0.75 37 5.1 16
180 M3GM 355 LKC 3GGM  s2" 993 95.8 95.8 0.78 0.74 42 5.2 18
200 M3GM 355 LKD 3GGM  s2" 993 96.0 95.9 0.79 0.75 46 5.2 20
224 M3GM 355 LKE 3GGM  s2" 993 96.1 96.1 0.79 0.74 52 5.3 22
250 M3GM 355 LKF 3GGM  s2" 992 96.0 96.1 0.79 0.75 58 5.1 24
280 M3GM 355 LKG 3GGM  s2" 993 96.2 96.2 0.79 0.74 65 5.3 28
355 M3GM 400 LKA 3GGM  s2" 993 96.3 96.3 0.81 0.78 80 5.3 30
400 M3GM 400 LKB 3GGM  s2" 994 96.5 96.5 0.81 0.78 89 5.5 33

3 425
450
500
M3GM
M3GM
M3GM
400 LKC
450 LA
450 LB
3GGM
3GGM
3GGM
 s2"
 s2"
 s2"
993
993
993
96.5
96.5
96.7
96.6
96.6
96.7
0.82
0.84
0.85
0.79
0.83
0.83
94
97
107
5.4
5.3
5.4
34
29
32
560 M3GM 450 LC 3GGM  s2" 993 96.8 96.8 0.85 0.84 119 5.4 34

1000 r/min = 6 poles 6600 V 50 Hz


150 M3GM 355 LKA 3GGM  s3" 991 95.2 95.1 0.77 0.72 18 5.2 8
160 M3GM 355 LKB 3GGM  s3" 990 95.3 95.2 0.78 0.73 19 5.2 9
180 M3GM 355 LKC 3GGM  s3" 990 95.4 95.4 0.78 0.74 21 5.0 9
200 M3GM 355 LKD 3GGM  s3" 990 95.6 95.5 0.77 0.72 24 5.2 11
280 M3GM 400 LKA 3GGM  s3" 993 95.9 95.8 0.78 0.74 33 5.1 14
315 M3GM 400 LKB 3GGM  s3" 993 96.1 96.0 0.79 0.75 37 5.2 15
355 M3GM 400 LKC 3GGM  s3" 993 96.3 96.2 0.79 0.75 41 5.4 17
375 M3GM 400 LKD 3GGM  s3" 993 96.4 96.3 0.80 0.76 43 5.4 17
400 M3GM 450 LA 3GGM  s3" 994 96.4 96.4 0.84 0.82 43 5.4 14
450 M3GM 450 LB 3GGM  s3" 994 96.5 96.5 0.84 0.83 48 5.3 15
500 M3GM 450 LC 3GGM  s3" 994 96.6 96.7 0.85 0.83 54 5.4 16
525 M3GM 450 LD 3GGM  s3" 993 96.6 96.7 0.85 0.84 56 5.5 16

The bullet in the product code indicates choice of mounting


When ordering variant code for protection type has to be added
arrangement (see ordering information page).
to the product code according to needs:
456 Ex nA design, fullling IEC 60079-15, with certicate.
480 Ex nA II according to ATEX directive 94/9/EC, temperature
class T3.

44 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 50C
Torque Load Starting Maximum Rotor Rotor Motor Sound
TN TS Tmax Power inertia time stalling inertia weight weight pressure
1)
Output Motor type factor cold 2) time hot kgm2 kg kg level LP 3)
kW Nm TN TN cos k kgm2 s s dB(A)

1000 r/min = 6 poles 3300 V 50 Hz


112 M3GM 315 LKA 1080 1.1 2.3 0.18 113 11 20 3.1 290 1230 65
125 M3GM 315 LKB 1206 1.1 2.2 0.18 125 11 20 3.3 300 1260 65
132 M3GM 315 LKC 1272 1.2 2.4 0.18 131 10 20 3.5 310 1300 65
140 M3GM 355 LKA 1347 0.8 2.2 0.14 139 14 20 5.0 370 1740 70
160 M3GM 355 LKB 1539 0.8 2.3 0.13 157 14 20 5.8 410 1870 70
180 M3GM 355 LKC 1731 0.9 2.3 0.13 175 13 20 6.1 430 1920 70
200 M3GM 355 LKD 1924 0.9 2.3 0.13 192 13 20 6.6 460 2010 70
224 M3GM 355 LKE 2154 0.9 2.3 0.13 213 12 20 7.2 490 2100 70
250 M3GM 355 LKF 2406 0.9 2.2 0.13 236 13 20 7.5 500 2130 70
280 M3GM 355 LKG 2694 0.9 2.3 0.13 261 12 20 8.3 550 2270 70
355 M3GM 400 LKA 3412 1.0 2.3 0.14 324 11 22 17.9 860 3100 78
400 M3GM 400 LKB 3843 1.1 2.4 0.14 360 11 22 21.1 980 3390 78
425
450
500
M3GM
M3GM
M3GM
400 LKC
450 LA
450 LB
4085
4327
4807
1.1
1.1
1.2
2.2
2.1
2.2
0.14
0.16
0.16
380
400
439
11
10
10
22
20
20
21.0
33.6
36.6
980
1050
1110
3380
4000
4150
78
78
78
3
560 M3GM 450 LC 5385 1.2 2.1 0.16 486 9 20 45.4 1290 4580 78

1000 r/min = 6 poles 6600 V 50 Hz


150 M3GM 355 LKA 1446 1.0 2.4 0.15 148 11 20 4.8 390 2040 70
160 M3GM 355 LKB 1543 1.0 2.4 0.15 157 11 20 5.0 410 2090 70
180 M3GM 355 LKC 1737 0.9 2.3 0.15 175 12 20 5.3 420 2140 70
200 M3GM 355 LKD 1929 1.0 2.4 0.15 192 11 20 5.7 440 2230 70
280 M3GM 400 LKA 2693 1.0 2.2 0.14 261 11 22 9.6 630 2740 78
315 M3GM 400 LKB 3030 1.1 2.2 0.14 291 11 22 10.9 680 2920 78
355 M3GM 400 LKC 3414 1.1 2.3 0.14 324 10 22 12.6 750 3150 78
375 M3GM 400 LKD 3606 1.1 2.2 0.14 340 10 22 14.3 830 3380 78
400 M3GM 450 LA 3844 1.2 2.2 0.17 360 10 20 30.8 1080 4030 78
450 M3GM 450 LB 4325 1.2 2.2 0.17 400 10 20 39.5 1170 4250 78
500 M3GM 450 LC 4806 1.2 2.2 0.17 439 10 20 43.9 1260 4480 78
525 M3GM 450 LD 5048 1.2 2.2 0.16 459 9 22 34.5 1260 4480 78

1)
315LK, 355LK: The given values of load inertia assume three starts from cold 400LK, 450L: Starting time with given values of the load inertia from cold
and two starts from warm conditions in succession against quadratic condition in succession against quadratic load torque with 80% of the rated
load torque with 90% of the rated torque at the rated speed and at 80% of the torque at the rated speed and at rated voltage.
rated voltage. 3)
The sound pressure levels are presented at no-load. Sound level values
400LK, 450L: The given values of load inertia assume two starts from cold and of 68-pole motors at no-load are typically 1...3 dB(A) higher than the
one start from warm conditions in succession against quadratic load torque corresponding values at no-load. The variation and measuring tolerance of
with 80% of the rated torque at the rated speed and at 80% of the the gures is +3 dB(A).
rated voltage.
To check validity against other starting requirements, contact ABB.
2)
315LK, 355LK: Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90% of the
rated torque at the rated speed and at rated voltage.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 45


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 50C
Efciency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

750 r/min = 8 poles 3300 V 50 Hz


160 M3GM 400 LKA 3GGM  s2" 744 94.9 94.8 0.76 0.71 39 5.0 19
180 M3GM 400 LKB 3GGM  s2" 744 95.1 95.1 0.77 0.73 43 4.9 19
200 M3GM 400 LKC 3GGM  s2" 744 95.3 95.3 0.78 0.73 47 5.0 21
224 M3GM 400 LKD 3GGM  s2" 744 95.5 95.4 0.78 0.74 53 5.2 23
250 M3GM 400 LKE 3GGM  s2" 745 95.7 95.6 0.78 0.73 59 5.4 26
280 M3GM 400 LKF 3GGM  s2" 745 95.9 95.8 0.78 0.74 65 5.4 29
315 M3GM 400 LKG 3GGM  s2" 744 95.9 95.8 0.78 0.74 74 5.4 33
355 M3GM 450 LA 3GGM  s2" 745 96.2 96.0 0.79 0.75 82 5.4 35
400 M3GM 450 LB 3GGM  s2" 745 96.3 96.1 0.79 0.74 92 5.4 40
450 M3GM 450 LC 3GGM  s2" 745 96.4 96.2 0.79 0.74 104 5.5 45

750 r/min = 8 poles 6600 V 50 Hz

3 160
180
200
M3GM
M3GM
M3GM
400 LKA
400 LKB
400 LKC
3GGM
3GGM
3GGM
 s3"
 s3"
 s3"
744
744
744
94.8
95.0
95.2
94.6
94.9
95.1
0.75
0.76
0.76
0.70
0.71
0.71
20
22
24
5.0
4.9
5.1
10
10
12
224 M3GM 400 LKD 3GGM  s3" 744 95.4 95.3 0.76 0.70 27 5.3 13
250 M3GM 400 LKE 3GGM  s3" 744 95.5 95.4 0.76 0.71 30 5.3 15
280 M3GM 400 LKF 3GGM  s3" 744 95.6 95.4 0.75 0.69 34 5.4 17
315 M3GM 450 LA 3GGM  s3" 745 95.9 95.7 0.79 0.75 36 5.4 16
355 M3GM 450 LB 3GGM  s3" 745 96.1 95.9 0.79 0.75 41 5.3 17
400 M3GM 450 LC 3GGM  s3" 745 96.2 96.1 0.79 0.75 46 5.3 19

The bullet in the product code indicates choice of mounting


When ordering variant code for protection type has to be added
arrangement (see ordering information page).
to the product code according to needs:
456 Ex nA design, fullling IEC 60079-15, with certicate.
480 Ex nA II according to ATEX directive 94/9/EC, temperature
class T3.

46 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Ex nA
Technical data for totally enclosed squirrel cage
three phase cast iron motors
IP 55 - IC 411 - Insulation class F, temperature rise class B, ambient temperature 50C
Torque Load Starting Maximum Rotor Rotor Motor Sound
TN TS Tmax Power inertia time stalling inertia weight weight pressure
1)
Output Motor type factor cold 2) time hot kgm2 kg kg level LP 3)
kW Nm TN TN cos k kgm2 s s dB(A)

750 r/min = 8 poles 3300 V 50 Hz


160 M3GM 400 LKA 2053 1.0 2.1 0.18 315 14 20 12.6 590 2400 75
180 M3GM 400 LKB 2310 1.0 2.0 0.18 352 14 20 14.4 640 2510 75
200 M3GM 400 LKC 2566 1.0 2.1 0.17 388 14 20 16.2 690 2630 75
224 M3GM 400 LKD 2873 1.1 2.2 0.18 430 12 20 20.7 800 2900 75
250 M3GM 400 LKE 3206 1.2 2.3 0.18 476 12 20 24.3 900 3130 75
280 M3GM 400 LKF 3591 1.2 2.2 0.17 528 11 20 26.1 950 3270 75
315 M3GM 400 LKG 4041 1.2 2.2 0.17 587 11 20 27.9 990 3370 75
355 M3GM 450 LA 4548 1.2 2.2 0.16 655 12 20 34.4 1180 4270 76
400 M3GM 450 LB 5125 1.2 2.3 0.16 730 11 20 42.4 1240 4420 76
450 M3GM 450 LC 5766 1.2 2.3 0.16 811 11 20 46.8 1330 4650 76

750 r/min = 8 poles 6600 V 50 Hz

3
160 M3GM 400 LKA 2054 1.0 2.3 0.17 315 13 20 10.8 590 2600 75
180 M3GM 400 LKB 2312 0.9 2.2 0.17 352 14 20 12.6 650 2770 75
200 M3GM 400 LKC 2568 1.0 2.3 0.16 388 13 20 14.4 710 2950 75
224 M3GM 400 LKD 2876 1.1 2.3 0.16 430 12 20 16.8 780 3180 75
250 M3GM 400 LKE 3210 1.1 2.3 0.16 476 12 20 18.0 820 3300 75
280 M3GM 400 LKF 3596 1.1 2.4 0.16 528 11 20 18.6 840 3360 75
315 M3GM 450 LA 4035 1.2 2.2 0.16 587 12 20 36.6 1120 4070 76
355 M3GM 450 LB 4548 1.2 2.2 0.16 655 12 20 34.4 1180 4230 76
400 M3GM 450 LC 5126 1.1 2.2 0.16 730 12 20 37.7 1270 4450 76

1)
400LK: The given values of load inertia assume three starts from cold and two 450L: Starting time with given values of the load inertia from cold condition
starts from warm conditions in succession against quadratic load torque with in succession against quadratic load torque with 85% of the rated torque
90% of the rated torque at the rated speed and at 80% of the rated voltage. at the rated speed and at rated voltage.
3)
450L: The given values of load inertia assume two starts from cold and one The sound pressure levels are presented at no-load. Sound level values
start from warm conditions in succession against quadratic load torque with of 68-pole motors at no-load are typically 1...3 dB(A) higher than the
85% of the rated torque at the rated speed and at 80% of the rated voltage. corresponding values at no-load. The variation and measuring tolerance of
To check validity against other starting requirements, contact ABB. the gures is +3 dB(A).
2)
400LK: Starting time with given values of the load inertia from cold condition
in succession against quadratic load torque with 90% of the rated torque at the
rated speed and at rated voltage.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 47


High voltage non-sparking motors - Variant codes
Code 1) Variant Motor size
315 355 400 450
Hazardous environments
Following codes have to be added to the product code according to needs.
456 Ex nA design, fullling IEC 60079-15, with certicate. P P P P
480 Ex nA II according to ATEX directive 94/9/EC, temperature class T3. P P P P
Balancing
423 Balanced without key P P P P
424 Full key balancing. P P P P
Bearings and lubrication
036 Transport lock for bearings. P P P P
037 Roller bearing at D-end. P P P P
107 Bearing mounted PT100 resistance elements. P P P P
651 Dial type thermometers (2 pcs) for bearings, without contacts. P P P P
654 Provision for vibration sensors (M8x1). P P P P
Branch standard designs
178 Stainless steel/acid proof bolts. P P P P
398 Motor designed for ambient temperature -20C to -40C. P P P P

3 Cooling system
044 Unidirectional fan, clockwise seen from D-end. NA P P P
045 Unidirectional fan, counter clockwise seen from D-end. NA P P P
Coupling
035 Assembly of customer supplied coupling-half P P P P

Drain holes
065 Plugged existing drain holes. P P P P
448 Draining holes with metal plugs. P P P P
Heating elements
450 Heating element, 100-120 V. P P P P
451 Heating element, 200-240 V. P P P P
Painting
114 Special paint colour, standard grade. P P P P
754 Painting system C5M - Coastal and offshore areas with high salinity P P P P
Protection
005 Metal protective roof, vertical motor, shaft down. P P P P
158 Degree of protection IP 65. P P P P
403 Degree of protection IP 56. P P P P
Rating & instruction plates
002 Restamping output, continuous duty. R R R R
135 Mounting of additional identication plate, stainless P P P P
Standards and regulations
010 Fullling CSA Safety Certicate. P P P P
778 GOST R Export/Import Certicate (Russia). P P P P
782 Fullling CQST Certicate requirements (China). P P P P

1)
Certain variant codes cannot be used simultaneously. P = New manufacture only.
R = On request.
NA = Not applicable.

48 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


High voltage non-sparking motors - Variant codes
Code 1) Variant Motor size
315 355 400 450
Stator winding temperature sensors
653 Pt-100 (12 pcs) inside stator slots. P P P P
Terminal box
021 Terminal box LHS (seen from D-end). P P P P
655 No terminal box, three (3) leads out 1.5 m (5 ft). P P P P
656 No terminal box, six (6) leads out 1.5 m (5 ft). P P P P
750 Star point terminal box. P P P P
Testing
Routine test report included as standard.
146 Type test with report for motor from specic delivery patch. P P P P
147 Type test with report for motor from specic delivery patch, customer witnessed. P P P P
762 Noise level test. P P P P
Variable speed drives
701 Insulated bearing at N-end. P P P P
Foundation and installation
Foundation studs P P P P
Sole plates without anchor bolts
Sole plates with anchor bolts
P
P
P
P
P
P
P
P
3
Slide rails for belt drives P P P P

1)
Certain variant codes cannot be used simultaneously. P = New manufacture only.
R = On request.
NA = Not applicable.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 49


HV Non-sparking and motors Sizes 315-450
Dimension drawings
Foot-mounted: IM B3 (IM 1001)

M000257

M000258
3

M000259
M000256

Motor size Poles A AA AB AC AD B B B BA BB C D DB E EG


315 LK 2 508 100 590 654 555 508 560 710 336 851 216 65 M20 140 42
315 LK 4-6 508 100 590 654 555 508 560 710 336 851 216 90 M24 170 52
355 LK 2 610 120 700 746 627 630 710 900 447 1077 254 70 M20 140 42
355 LK 4-6 610 120 700 746 627 630 710 900 447 1077 254 100 M24 210 51
400 L 2 710 150 840 834 627 900 1000 - 410 1156 224 80 M20 170 42
400 L 4-8 710 150 840 834 627 900 1000 - 410 1156 224 110 M24 210 50
400 LK 2 710 150 840 834 627 900 1000 1120 410 1316 224 80 M20 170 42
400 LK 4-8 710 150 840 834 627 900 1000 1120 410 1316 224 110 M24 210 50
450 L 2 800 160 950 966 613 1000 1120 1250 451 1421 250 80 M20 170 42
450 L 4-8 800 160 950 966 613 1000 1120 1250 451 1421 250 120 M24 210 50

Motor size Poles F G GA GD H HA HC HD K L LD O


315 LK 2 18 58 69 11 315 40 644 1055 28 1490 355 115
315 LK 4-6 25 81 95 14 315 40 644 1055 28 1521 385 115
355 LK 2 20 62.5 74.5 12 355 52 725 1138 35 1764 398 250
355 LK 4-6 28 90 106 16 355 52 725 1138 35 1834 468 130
400 L 2 22 71 85 14 400 45 814 1225 35 1851 458 300
400 L 4-8 28 100 116 16 400 45 814 1225 35 1891 498 200
400 LK 2 22 71 85 14 400 45 814 1225 35 2011 478 300
400 LK 4-8 28 100 116 16 400 45 814 1225 35 2051 518 200
450 L 2 22 71 85 14 450 81 933 1378 42 2147 485 300
450 L 4-8 32 109 127 18 450 81 933 1378 42 2187 525 200

Tolerances:
A, B, C 0.8 Above table gives the main dimensions in mm.
D ISO m6
For detailed drawings please see our web-pages 'www.
F ISO h9
abb.com/motors&generators' or contact us.
H +0 -1.0

50 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking motors Sizes 315-450
Dimension drawings
Flange-mounted;IM V1 (IM 3011)

M000257

M000258
3

M000261
M000260

Motor size Poles AC D DB E EG F G GA GD HB


315 LK 4-6 645 90 M24 170 52 25 81 95 14 731
355 LK 4-6 740 100 M24 210 51 28 90 106 16 774
400 L 4-8 827 110 M24 210 50 28 100 116 16 816
400 LK 4-8 810 110 M24 210 50 28 100 116 16 816
450 L 4-8 966 120 M24 210 50 32 109 127 18 887

Motor size Poles L LA LB LD M N O P S T


315 LK 4-6 1521 25 1351 1115 600 550 115 660 23 6
355 LK 4-6 1834 25 1624 1386 740 680 130 800 23 6
400 L 4-8 1891 26 1681 1400 940 880 200 1000 28 6
400 LK 4-8 2051 26 1841 1540 940 880 200 1000 28 6
450 L 4-8 2187 33 1977 1645 1080 1000 200 1149 28 6

Tolerances:
D ISO m6
F ISO h9
N ISO js6 (315_)

Above table gives the main dimensions in mm.


For detailed drawings please see our web-pages 'www.
abb.com/motors&generators' or contact us.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 51


HV Non-sparking motors Sizes 315-450
Dimension drawings
Foot- and ange-mounted motors: IM B35 (IM 2001)

M000361
Motor size Poles A AA AB AC AD B B B BA BB C D DB E EG F G
315LK 2 508 100 590 885 555 508 560 710 336 851 216 65 M20 140 42 18 58
315LK 4-6 508 100 590 885 555 508 560 710 336 851 216 90 M24 170 52 25 81
355LK 2 610 120 700 1027 627 630 710 900 447 1077 254 70 M20 140 42 20 62.5
355LK 4-6 610 120 700 1027 627 630 710 900 447 1077 254 100 M24 210 51 28 90
400L 2 710 150 840 1127 627 900 1000 - 410 1156 224 80 M20 170 42 22 71
400L 4-12 710 150 840 1127 627 900 1000 - 410 1156 224 110 M24 210 50 28 100
400LK 2 710 150 840 1127 627 900 1000 1120 410 1316 224 80 M20 170 42 22 71
400LK 4-8 710 150 840 1127 627 900 1000 1120 410 1316 224 110 M24 210 50 28 100
450L 2 800 160 950 1188 613 1000 1120 1250 451 1421 250 80 M20 170 42 22 71
450L 4-8 800 160 950 1188 613 1000 1120 1250 451 1421 250 120 M24 210 50 32 109

Motor size Poles GA GD H HA HC HD K L LD O LA LB M N P S T


315LK 2 69 11 315 40 643 1055 28 1490 355 115 25 1350 600 550 660 23 6
315LK 4-6 95 14 315 40 643 1055 28 1521 385 115 25 1350 600 550 660 23 6
355LK 2 74.5 12 355 52 725 1138 35 1764 398 250 25 1624 740 680 800 23 6
355LK 4-6 106 16 355 52 725 1138 35 1834 468 130 25 1624 740 680 800 23 6
400L 2 85 14 400 45 814 1225 35 1851 458 300 26 1681 940 880 1000 28 6
400L 4-12 116 16 400 45 814 1225 35 1891 498 200 26 1681 940 880 1000 28 6
400LK 2 85 14 400 45 814 1225 35 2011 478 300 26 1841 940 880 1000 28 6
400LK 4-8 116 16 400 45 814 1225 35 2051 518 200 26 1841 940 880 1000 28 6
450L 2 85 14 450 81 933 1378 42 2147 485 300 33 1977 1080 1000 1149 28 6
450L 4-8 127 18 450 81 933 1378 42 2187 525 200 33 1977 1080 1000 1149 28 6

Tolerances:
A, B, D 0.8 Above table gives the main dimensions in mm.
D ISO m6
F ISO h9 For detailed drawings please see our web-pages 'www.
abb.com/motors&generators' or contact us.
H +0 -1.0

52 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Accessories
Foundation studs Slide rails

M000263
M000262

Frame size
315
Set code
FOST315-M3
Frame size
315
Set code
SLRA315-M3 3
355 FOST355-M3 355 SLRA355-M3
400 FOST400-M3 400 SLRA400-M3
450 FOST450-M3 450 SLRA450-M3
The set code has to be mentioned on order. The set code has to be mentioned on order.

Sole plates Sole plates

M000327
M000327

With anchor bolts for concrete foundation Without anchor bolts


Frame size Set code Frame size Set code
315 SOPL315A-M3 315 SOPL315-M3
355 SOPL355A-M3 355 SOPL355-M3
400 L SOPL400A-M3 400 L SOPL400-M3
400 LK SOPL400A-M3LK 400 LK SOPL400-M3LK
450 SOPL450A-M3 450 SOPL450-M3
The set code has to be mentioned on order. The set code has to be mentioned on order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 53


Accessories
Protective roof

Variant code 005


Motor Pole L LL
size no
315 LK 4-6 1591 1421
355 LK 4-6 1951 1741
400 L 4-8 2008 1798
400 LK 4-8 2168 1958

LL
450 L 4-8 2389 2179

M000264
3

Provision for vibration sensors

X
M000362

Provision for vibration sensors M8x1. XYZ-directions. Available only for D-end.

54 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Motor construction

Typical exploded view of high voltage cast iron motor

M000363
1 Stator frame 17 Valve disc with labyrinth seal, D-end
2 End shield, D-end 18 Bearing, N-end
3 Screws for end shield, D-end 19 Inner bearing cover, N-end
4 End shield, N-end 20 Spring
5 Screws for end shield, N-end 21 Screws for bearing cover, N-end
6 Rotor with shaft 22 Fan
7 Key, D-end 23 Fan cover
8 Main terminal box 24 Screws for fan cover
9 Middle box 25 Rating plate
10 Screws for terminal box cover 26 Lubrication plate
11 Outer bearing cover, D-end 27 Auxiliary terminal box
12 Valve disc with labyrinth seal, D-end 28 Grease nipple, D-end
13 Bearing, D-end 29 Grease nipple, N-end
14 Inner bearing cover 30 SPM nipple, D-end
15 Screws for bearing cover, D-end 31 SPM nipple, N-end
16 Outer bearing cover, N-end 32 Additional identication plate

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 55


HV Non-sparking cast iron motors in brief, basic design
Motor size 315 355 400 450
Stator Material Cast iron EN-GJL-250 EN 1561
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014
Paint thickness Two-pack epoxy paint, thickness 180 m
Bearing end shields Material Cast iron EN-GJL-200 SFS-EN 1561
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014
Paint thickness Two-pack epoxy paint, thickness 180 m
Bearings D-end 2 pole 6316M/C3 6316M/C3 6317M/C3 6317M/C3
4-8 pole 6319/C3 6322/C3 6324/C3 6326M/C3
N-end 2 pole 6316M/C3 6316M/C3 6317M/C3 6317M/C3
4-8 pole 6316/C3 6316/C3 6319/C3 6322/C3
Axially-locked Inner bearing cover As standard, locked at D-end
bearings
Bearing seal As standard, labyrinth seal in both ends.
Lubrication Regreasable bearings
Regreasing nipples M10x1 DIN 71412 A
SPM-nipples As standard

3 Rating and
lubrication plate
Material Stainless steel, EN 10088, thickness 0.5 mm.

Terminal box Frame material Structural steel S235JRG2-EN-10025, thickness 3 mm.


Cover material Structural steel S235JRG2-EN-10025, thickness 3 mm.
Cover screws material Blue passivated.
Connections Cable entries Blind gland plate.
Terminals 3 terminals for connection with cable lugs (not included)
Grounding locations on frame and terminal box (in- and outside)
Fan Material Glass reinforced polypropylene, aluminum, steel or glass reinforced polyamide fan with
metal hub.
Direction of rotation / fans (IC411)
- glass reinforced polypropylene bidirectional
- aluminum birectional
- steel bidirectional
- glass reinforced polyamide fan unidirectional.
Fan cover Material Steel
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014
Paint thickness Two-pack epoxy polyester powder, thickness 80 m
Stator winding Material Form wound copper, VPI
Insulation Insulation class F
Winding protection PT100, 6 pieces
Rotor winding Material Pressure die-cast aluminum
Balancing method Half key balancing as standard
Key ways Open key way
Heating elements On request 1x200 W 1x200 W 1x300 W 1x400 W
Drain holes Standard, open on delivery.
Enclosure IP 55, higher protection as option.
Cooling method IC 411

56 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors
Squirrel cage three phase high voltage motors,
Up to 2800 kW
For Zone 2

www.abb.com/motors&generators
> Motors
>> Motors and Generators for Hazardous Areas

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 57


Contents Page
General Information 59
Enclosure and Cooling 60
Type designation 62
High voltage terminal box for non-sparking motors 63
Auxiliary boxes 67
Bearings 68
Vibrations 73
Notes 74
Technical Data 75
Technical Data, Non-sparking cast iron motors, HXR 75
Technical Data, Non-sparking modular motors 81
Dimension Drawings, Non-sparking engineered motors, HXR, IC411 93
Dimension Drawings, Non-sparking engineered motors, AMA, IC611 99
Dimension Drawings, Non-sparking engineered motors, AMA, IC81W 105

ABB reserves the right to change the design,

3 technical specication and dimensions


without prior notice.

58 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


General Information
ABB's engineered motors are tailor-made to meet its The AMA range features a welded steel frame and is
customers' needs. All ABB engineered motors are available as standard with the following cooling methods
congured and optimized individually for each order and and protection types: IC 611 / IP 55 and IC 81W / IP 55.
application. Please contact ABB for further information. The standard shaft heights are between 400 and
500 mm.
This catalogue contains information on ABBs standard
construction squirrel-cage induction motors operating at The HXR range features a rugged cast iron frame and
50 Hz and with synchronous speed from 500 to is totally enclosed fan cooled motor of IC 411 / IP 55.
3000 rpm. The output range is up to 2800 kW. HXR motors have standard shaft heights between 355
and 560 mm.
This catalogue describes two different motor types,
the AMA range and the HXR range. Both motor types The table below shows the available output power,
can be operated with variable speed drives or used voltage range and pole numbers for the motor types
as induction generators and motors can be mounted described in this catalogue.
horizontally or vertically. Either motor can be used for
both standard and special applications.

Output (kW) at 50 Hz Output (kW) at 50 Hz


HXR AMA
Poles 3 kV 6 kV 3 kV 6 kV
2 100 - 1600 160 - 1250 630 - 2500 630 - 2500 3
4 100 - 2000 160 - 1800 630 - 2800 630 - 2500
6 160 - 1800 125 - 1600 450 - 2000 450 - 2000
8 180 - 1600 180 - 1400 280 - 1600 280 - 1600
10 140 - 1250 200 - 1120 200 - 1120 200 - 1120
12 125 - 1000 140 - 900 140 - 900 140 - 900
Output ranges of ABB motors (Temperature rise class B, insulation class F). Other voltages on request.

Higher voltage, speed and power ratings are available


on request. Please contact ABB for further information.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 59


Enclosure and Cooling
Standard combinations used for AMA-motors are:

IC 611 / IP 55
In this design the fully enclosed motor has an air-
to-air heat exchanger mounted on the motor. Shaft
mounted fans are tted both inside and outside of the
casing to supply the inside and outside cooling circuits
respectively. The motor is protected against dust and
splashing water from any direction.

IC 81W / IP 55
This fully enclosed motor is tted with an air-to-water

3 heat exchanger. A shaft mounted fan is tted inside the


casing to supply the internal cooling circuit. Motor is
protected against dust and splashing water from any
direction.

The terminal boxes have a protection of at least IP 55.

60 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


IC 411 / IP55 HXR motor
The HXR motor has an external shaft mounted fan protected against dust and water jets. The principle of
that use the surrounding air for cooling. The motor is this motor is shown in below:

Sectional drawing of IC 411 / IP55 motor.

3
Protection denition IP55 Method of Cooling (IC 411)
In a dust-protected motor, some dust can ingress the Frame surface cooled:
motor but it does not enter in sufcient quantity to The primary coolant is circulated in a closed circuit
interfere with the motor's operation. in the motor and gives its heat through the external
surface of the motor (in addition to the heat transfer
The motor protected against water jets:
via the stator core and other heat conducting parts) to
Water projected by a nozzle against the motor from any
the nal coolant which is the surrounding medium. The
direction shall have no harmful effect.
surface may be plain or ribbed, with or without an outer
shell to improve the heat transfer.
Self circulation:
The coolant is moved dependent on the rotational
speed of the main motor either by action of the rotor
alone or by means of a component designed for this
purpose and mounted directly on the rotor of the main
motor, or by a fan or pump unit mechanically driven by
the rotor or the main motor.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 61


Type designation
The type designation of the AMA motor follows
the coding principle shown below.

Example: AMA 450L4A BATH


1 AM Stands for Alternating Current Machines
2 A Indicates the type of machine, A - E = SCIM, K - P = WRIM
3 450 Frame size in mm, 400, 450 or 500
4 L Frame length, S = small, M = medium or L = long
5 4 Number of poles
6 A Stands for the IC/IP combination
D = IC01 / IP23 [WP I] L = IC81W / IP54 (55) [TEWAC]
W = IC01 / IPW24 [WP II] A = IC611 / IP55 [TEAAC]
P = IC11, 21, 31 / IP23, 54 (55) [OPV, TEPV]
7 B Mounting arrangement, B = IM1001 (Horizontal), V = IM4011 (Vertical)
8 A Bearing type, A = antifriction, S = sleeve
9 T Indication of special construction
T = separate ventilation X = electrically special
N = Non-sparking design F = frequency converter drive Y = mechanically special
10 H Location of manufacture

3 The type designation of the HXR motor follows


the coding principle shown below.

Example: HXR 355LA4


1. HXR Stands for the HXR machine family, three digits.
2. 355 Shaft height in mm, three digits.
3. L Frame length, one digit.
4. A Core length, one digit.
5. 4 Number of poles.

62 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


High voltage terminal box for non-sparking motors
The picture shows the high voltage terminal box with its
main technical data below.

Technical data: Materials:


Voltage (max.) 6.6 kV Box welded sheet steel (thickness
Current (max.) 400 A min. 3 mm)
Dynamic short circuit current 75 kA (0.25 s) Cable gland plate steel
No of cables (max.) 1 per phase Connection screws Bronze Bz
Cross section of cables (max.) 300 mm2/cable Isolators epoxy casting resin or
Cable gland blind gland (1 pce) polyurethane resin
Clearance (min.) 60 mm Grounding pad stainless steel
Creepage (min.) 119 mm
Gross volume 47.3 dm3 Other features:
Usable volume 42.1 dm3 - rigid welded construction
Connection screws M16 (3 pcs) - ample size for making connections of supply cables
Connection nuts tightening torque 40 Nm - box turnable to allow cable entry from left or right side
Ground connections M12 (both in- and out - box turnable in steps of 90
side) - either 3-phase or 1-phase cables can be connected
Weight 33 kg - pressure relief plate in the bottom of the box in case
Protection IP66 of an arching short circuit
Standard DIN 42962 TEIL 1, A2 - different cable glands available
- terminal box tested acc. to IEC 298 concerning
internal arc strength
3

Figure above: High voltage terminal box. Dimensions in mm.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 63


High voltage terminal box for non-sparking motors
Figure below shows the high voltage terminal box with
its main technical data.

Technical data: Materials:


Voltage (max.) 6.6 kV Box welded sheet steel (thickness
Current (max.) 800 A min. 3 mm)
No of cables (max.) 2 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators polyurethane resin or epoxy
Clearance (min.) 70 mm casting resin
Creepage (min.) 119 mm Grounding pad stainless steel
Gross volume 194.6 dm3
Usable volume 186.5 dm3 Other features:
Connection screws (M16x1/M12x2/ - rigid welded construction
M10x2)/phase - ample size for making connections of supply cables
Tightening torque for - box turnable to allow cable entry from left or right side
connection nuts 40 Nm - box turnable in steps of 90
Ground connections M12 (both in- and - either 3-phase or 1-phase cables can be connected
outside) - pressure relief plate in the bottom of the box in case
Weight 90 kg of an arching short circuit
Protection IP66 - different cable glands available
3 Standards DIN 42962 Teil 2, D2
(internal dimensions)

Figure above: High voltage terminal box. Dimensions in mm.

64 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


High voltage terminal box for non-sparking motors
The picture shows high voltage terminal box with its
main technical data below.

Technical data: Materials:


Voltage (max.) 11.0 kV Box welded sheet steel (thickness
Current (max.) 400 A min. 3 mm)
No of cables (max.) 1 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators epoxy casting resin
Clearance (min.) 100 mm Grounding pad stainless steel
Creepage (min.) 158 mm
Gross volume 122 dm3 Other features:
Usable volume 116 dm3 - rigid welded construction
Connection screws M16 (3 pcs) - ample size for making connections of supply cables
Connection nuts tightening torque 40 Nm - box turnable to allow cable entry from left or right side
Ground connections M12 (both in- and - box turnable in steps of 90
outside) - either 3-phase or 1-phase cables can be connected
Weight 62 kg - pressure relief plate in the bottom of the box in case
Protection IP66 of an arching short circuit
Standard DIN 42962 TEIL 2, C2 - different cable glands available

Figure above: High voltage terminal box. Dimensions in mm.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 65


Dimensions for terminal box inlet, blind ange
As standard, main terminal boxes are with blind ange.
Cable glands are available on request.

3
Figure above: Blind ange FL 33 for main terminal box.

66 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Auxiliary boxes
As standard motors in safe area are equipped with one As standard motors in hazardous area are equipped
common auxiliary terminal box for monitoring devices with two auxiliary terminal boxes, one for monitoring
and space heaters. devices and one for space heaters.

Type designation Use Size (W x L x H)


mm
ZWA ALX122208 Standard 125 x 222 x 81

ZWA ALX233318 Is used when additional space is needed 230 x 330 x 180

Table above: Standard auxiliary terminal boxes.

The typical arrangements for standard terminal boxes the motor. Additional terminals can be supplied on
are shown below. The number of terminal blocks request.
depends on the number of accessories equipped with

Standard terminal box ZWA ALX122208


with terminal blocks and cable glands. 3
1) Cable gland M20x1.5 for cable outer
diameter 10...14 mm (2 pcs)
2) Threaded hole for cable gland M16x1.5
(3 pcs), plugged.

Standard terminal box ZWA ALX233318


with terminal blocks and cable glands.
1) Cable gland M20x1.5 for cable outer
diameter 10...14 mm (4 pcs)
2) Threaded hole for cable gland M16x1.5
(3 pcs), plugged.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 67


Bearings
Horizontal motors
Horizontal motors 355 - 500 have deep groove ball stated in table below and the bearing construction is
bearings in both ends. HXR 560 has a double bearing shown in the gures on page 69.
arrangement (deep groove ball bearing and a cylindrical
The standard bearing solution is designed to carry the
roller bearing) at D-end and cylindrical roller bearing at
weight of the typical coupling half and the weight of
N-end (only horizontal motor available).
the motor rotor only. Any additional radial or axial force
The bearing in D-end is axially locked in horizontal caused by driven equipment may need the bearings to
motors. Standard bearings of horizontal motors are be specially constructed.

Table below: Standard bearings for horizontal motors.

Frame size Poles D-end N-end

HXR 355 2 6317M/C3 6317M/C3


HXR 355 4 6322/C3 6319/C3
HXR 400 2 6317M/C3 6317M/C3

3 HXR 400
HXR 450
4
2
6324/C3
6317M/C3
6319/C3
6317M/C3
HXR 450 4 6324/C3 6322/C3
HXR 500 2 6319M/C3 6319M/C3
HXR 500 4 6326/C3 6324/C3
HXR 560 4 6034/C3 + NU1034/C3 NU322/C3
HXR 560 2 sleeve* sleeve*
AMA 400 2 6319M/C3 6319M/C3
AMA 400 4 6324/C3 6319/C3
AMA 450 2 6319M/C3 6319M/C3
AMA 450 4 6326/C3 6322/C3
AMA 500 4 6330/C3 6324/C3
AMA 500 2 sleeve* sleeve*
* See section sleeve bearings.

68 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Figure below: Standard bearing construction for horizontally mounted motors, frame sizes 355-500.

1 Groove ball bearing


2 Inner bearing cover
3 Grease valve
4 Outer bearing cover
5 Circlip
6 Hexagon screw
7 Spring
8 O-ring

3
D-end, axially locked N-end, axially free

Figure below: Standard bearing construction for horizontally mounted motors HXR 560.

1 Inner bearing cover 1 Cylindrical roller bearing


2 Cylindrical roller bearing 2 Inner bearing cover
3 Grease valve 3 Grease valve
4 Outer bearing cover 4 Outer bearing cover
5 Deep groove ball bearing 5 Circlip
6 Outer bearing cover lid 6 Hexagon screw
7 Labyrinth seal
8 Grub screw

D-end, axially locked N-end, axially free

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 69


Bearing rating life
Most motors with standard bearings have a rated life The basic rated life L10h is the number of hours at rated
time L10h in excess of 100000 h. Rated life time for frame bearing load and speed that 90% of a group of identical
500, 2-pole, may be less than 100000h. The life times bearings will complete or exceed before the rst
are calculated in accordance with ISO R 281-1. evidence of failure.

Lubrication intervals
The motors are equipped with greasing nipple(s) in grease and the interval of greasing are stamped on the
both ends for lubricating the bearings. The greasing relubrication plate. The values are also shown in the
nipples are located on top of the motor. The amount of table below.

Table below: Relubrication intervals and grease amount.

Bearing Amount of Lubrication intervals in running hours at different speeds [rpm]


type grease [g] 3600 3000 1800 - 1500 1200 - 1000 900 - 750 600 - 500

6317 35 800 2200 8800 8800 8800 8800

3 6319
6322
45
60
400 1600 6600
6600
8800
8800
8800
8800
8800
8800
6324 70 4400 8800 8800 8800
6326 80 4400 8800 8800 8800
6034 55 1600 3300 6600 8800
NU1034 55 1600 3300 4400 8800
NU322 60 3300 4400 4400 8800
7317 35 1100 4400 4400 4400 6600
7319 45 800 3300 4400 4400 6600
7322 60 3300 4400 4400 6600
7324 70 2200 4400 4400 6600
NB: Ball bearings on vertical motors should be lubricated twice as frequently as horizontal motors. The motor type is indicated by the rst letter
of the bearing type (6).

70 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Sleeve bearings
The axial oat of rotor is as standard 8 mm from Sleeve bearings are generally self-cooled, oil ring
mechanical center. The running center locates within lubricated but some require external ood lubrication.
the oat area and therefore operation is also allowed Please see the lubrication table below for standard
while machine is uncoupled, e.g. during test run. A lubrication requirements based on a maximum 40 C
pointer showing running center with regard to end limits ambient and 50 Hz operation. Consult ABB for ambient
is available as standard. Continuous axial forces are temperatures above 40 C, and/or for self-cooling of
not permitted and therefore limiting type coupling is bearings where ood lubrication is standard. Those
needed to ensure rotor location within axial oat range. units requiring ood lubrication are supplied with
On request, when special axial oat is at least 3 mm, provisions only. Refer oil supply pressure, type of oil,
magnetic running center can be adjusted within and location of provisions to factory for review prior to
2.4 mm from mechanical center (option). order acceptance.

Table below: Sleeve bearings and lubrication method.

Frame size Poles D-end bearing N-end bearing Lubrication Method

HXR 355 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)


HXR 355 4 EFZLB 9-90 EFZLQ 9-90 Self lubrication
HXR 400 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)
HXR 400
HXR 450
4
2
EFZLB 9-100
EFZLB 9-80
EFZLQ 9-100
EFZLQ 9-80
Self lubrication
Oil circulation 1)
3
HXR 450 4 EFZLB 9-100 EFZLQ 9-100 Oil circulation 1)
HXR 450 6 EFZLB 9-100 EFZLQ 9-100 Self lubrication
HXR 500 2 EFZLB 9-90 EFZLQ 9-90 Oil circulation 1)
HXR 500 4 EFZLB 11-100 EFZLQ 9-100 Oil circulation 1)
HXR 500 6 EFZLB 11-100 EFZLQ 9-100 Self lubrication
HXR 560 2 EFZLB 14-125 EFZLQ 14-125 Oil circulation
HXR 560 4 EFZLB 14-125 EFZLQ 14-125 Oil circulation 1)
HXR 560 6 EFZLB 14-125 EFZLQ 14-125 Self lubrication
HXR 560 8 EFZLB 14-140 EFZLQ 14-140 Self lubrication
AMA 400 2 EFZLB 9-80 EFZLQ 9-80 Self lubrication
AMA 400 4 EFZLB 9-100 EFZLQ 9-100 Self lubrication
AMA 450 2 EFZLB 9-80 EFZLQ 9-80 Self lubrication
AMA 450 4 EFZLB 11-125 EFZLQ 9-100 Self lubrication
AMA 500 2 EFZLB 9-100 EFZLQ 9-100 Oil circulation 1)
AMA 500 4 EFZLB 14-125 EFZLQ 11-125 Self lubrication
AMA 500 6 EFZLB 14-140 EFZLQ 11-125 Self lubrication
1)
Possibility for self lubrication, please contact ABB

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 71


Vertical motors
Vertical motors 355 - 500 have deep groove ball bearing Standard bearing solution is designed to carry the
in D-end and single-row angular contact ball bearing in weight of the typical coupling half and the weight of
N-end. the motor rotor only. Any additional radial or axial
force caused by driven equipment may require special
The bearing in D-end is axially free in vertical motors
bearing construction.
when an angular contact ball bearing is mounted in
N-end. Standard bearings of vertical motors are stated
in table below and the bearing construction is shown in
gure below.

Table below: Standard bearings for vertical motors.

Frame size Poles D-end N-end

HXR 355 2 6317M/C3 7317 BMP 1)


HXR 355 4 6322/C3 7319 BMP
HXR 400 2 6317M/C3 7317 BMP 2)
HXR 400 4 6324/C3 7319 BMP
HXR 450 4 6324/C3 7322 BMP
HXR 500 4 6326/C3 7324 BMP

3 AMA 400
AMA 450
4
4
6324/C3
6326/C3
7319 BMP
7322 BMP
AMA 500 4 6330/C3 7324 BMP
1)
60 Hz motors have ball bearing 6317M/C3.
2)
Only for 50 Hz motors.

Figure below: Standard bearing construction of vertically mounted motor, frame sizes 355 - 500. On the left the
bearing is "axially locked" angular contact ball bearing and on the right is an axially free deep
groove ball bearing.

1 Bearing 5 Circlip
2 Inner bearing cover 6 Hexagon screw
3 Grease valve 7 Spring
4 Outer bearing cover 8 O-ring

72 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Bearing rating life
The bearing rates for all vertical motors with standard bearings will complete or exceed before the rst
bearings have a rated life time L10h in excess of evidence of failure.
100000 h. The life times are calculated in accordance
Additional axial force from the driven equipment is not
with ISO R 281-1.
allowed.
The basic rated life L10h is the number of hours at rated
bearing load and speed that 90% of a group of identical

Lubrication intervals
The motors are equipped with greasing nipple(s) in relubrication plate. The values are also available in the
both ends for lubricating the bearings. The amount of table on page 70.
grease and the interval of greasing are stamped on the

Vibrations 3
Standard design
The standard motors manufactured according to IEC- Other vibration limit specication, such as IEC 60034-14
standard satisfy the Grade A vibration limits found in Grade B, NEMA special motor or API 541, are available
IEC 60034-14. The table below shows the maximum on request.
accepted values.

Table below: Standard design unltered vibration limits for IEC motors.

Poles Speed [rpm] Bearing housing Relative shaft Combined runout


vibration vibration
2 1800 < n 3600 2.3 mm/s rms 65 m p-p 16 m p-p
4 n 1800 2.3 mm/s rms 90 m p-p 23 m p-p

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 73


Notes
All ratings in this catalogue are designed for the
following:
- Class F insulation / Maximum temperature rise of
80 C by resistance
- Maximum 40 C ambient
- Altitude of 1000 meters or less
- Data presented in rating lists are typical values.
Guaranteed values are available on request.
All engineered motors are optimized for the
specied application. Accurate motor data will be
given on request at quotation phase. Legally binding
performance and specication data is given to the end
user once each order is conrmed.
- Please provide load data and starting requirements to
ABB for nal design conrmation.

74 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


100 HXR 355LA2 2963 93.1 92.5 0.91 0.90 23 5.8 6 322 0.7 2.4 2.7 1570 85
125 HXR 355LA2 2967 93.8 93.4 0.91 0.90 28 6.1 7 402 0.7 2.6 2.7 1570 85
160 HXR 355LA2 2967 94.5 94.3 0.92 0.91 35 6.1 8 515 0.7 2.5 3.0 1650 85
200 HXR 355LA2 2967 94.9 94.8 0.93 0.92 44 6.1 9 644 0.7 2.5 3.0 1650 85
224 HXR 355LA2 2968 95.1 95.1 0.92 0.90 49 6.1 11 721 0.7 2.5 3.0 1650 85
250 HXR 355LB2 2971 95.6 95.6 0.91 0.90 62 6.4 15 900 0.7 2.6 3.3 1750 85
315 HXR 400LC2 2981 96.2 95.9 0.90 0.89 79 6.8 20 1137 0.6 2.7 5.7 2590 82
355 HXR 400LD2 2980 96.3 96.1 0.91 0.89 88 6.7 21 1282 0.6 2.7 6.0 2630 82
400 HXR 400LE2 2982 96.5 96.4 0.90 0.89 100 6.7 24 1441 0.6 2.5 6.8 2810 82
450 HXR 400LF2 2982 96.6 96.5 0.90 0.89 110 6.7 26 1601 0.6 2.5 7.3 2930 82
560
630
710
HXR 450LG2
HXR 450LJ2
HXR 500LH2
2984
2983
2989
96.7
96.9
96.8
96.5
96.8
96.5
0.92
0.93
0.91
0.90
0.92
0.89
136
151
175
7.3
7.3
7.4
32
31
44
2016
2273
2556
0.6
0.7
0.6
2.9
2.8
3.0
11.9
13.9
23.7
4000
4390
5820
85
85
86
3
800 HXR 500LK2 2986 96.9 96.8 0.93 0.92 192 7.0 38 2878 0.6 2.7 25.8 6110 86
900 HXR 500LL2 2988 97.1 96.9 0.92 0.91 215 7.2 46 3196 0.6 2.8 27.7 6380 86
1000 HXR 500LP2 2988 97.2 97.0 0.91 0.90 243 7.3 54 3579 0.7 2.8 31.4 6860 86
1250 HXR 560LM2 2989 97.4 97.2 0.92 0.91 300 7.3 70 4473 0.6 2.9 45.6 9810 87
1400 HXR 560LR2 2990 97.6 97.4 0.93 0.92 339 7.3 72 5111 0.6 2.9 53.0 10790 87
1600 HXR 560LS2 2991 97.6 97.5 0.92 0.91 370 7.6 84 5524 0.6 3.0 58.0 11360 87

1500 r/min = 4 poles 3000 V 50 Hz


100 HXR 355LA4 1487 93.9 93.2 0.83 0.79 25 6.1 10 642 1.0 2.4 4.7 1620 77
125 HXR 355LA4 1485 94.3 93.9 0.84 0.80 30 6.0 12 804 1.0 2.3 4.8 1620 77
160 HXR 355LA4 1485 94.8 94.5 0.85 0.82 38 6.1 14 1029 1.0 2.3 4.8 1630 77
200 HXR 355LA4 1484 95.0 94.9 0.85 0.82 48 5.9 17 1287 1.0 2.2 4.8 1630 77
224 HXR 355LA4 1485 95.3 95.2 0.85 0.82 53 6.0 18 1441 1.0 2.2 5.1 1670 77
250 HXR 355LB4 1485 95.5 95.4 0.85 0.82 59 6.1 21 1607 1.0 2.2 5.4 1720 77
280 HXR 355LB4 1486 95.7 95.6 0.84 0.81 67 6.2 24 1799 1.0 2.2 5.7 1770 77
315 HXR 355LC4 1487 95.9 95.8 0.84 0.81 75 6.2 27 2023 1.0 2.2 6.3 1870 77
400 HXR 400LC4 1491 96.4 96.3 0.86 0.83 93 6.1 31 2562 0.8 2.2 11.4 2630 76
450 HXR 400LD4 1490 96.6 96.6 0.87 0.85 103 6.0 31 2884 0.8 2.1 12.5 2750 76
500 HXR 400LE4 1490 96.7 96.7 0.88 0.86 113 6.0 32 3204 0.8 2.1 13.6 2880 76
560 HXR 400LG4 1491 96.9 96.8 0.87 0.85 128 6.5 40 3586 0.9 2.2 15.2 3070 76
630 HXR 450LG4 1492 97.1 97.1 0.88 0.86 160 6.4 48 4545 0.8 2.3 26.7 4170 77
710 HXR 450LJ4 1492 97.2 97.2 0.88 0.86 180 6.4 52 5120 0.8 2.2 29.4 4420 77
800 HXR 450LL4 1492 97.3 97.3 0.88 0.86 201 6.5 58 5760 0.9 2.2 33.0 4740 77
900 HXR 500LJ4 1491 97.2 97.3 0.90 0.88 220 6.5 58 6404 0.7 2.4 48.5 6010 77
1000 HXR 500LK4 1492 97.4 97.4 0.90 0.89 245 6.3 62 7167 0.7 2.3 53.1 6310 77
1120 HXR 500LL4 1492 97.4 97.5 0.90 0.89 274 6.2 68 7998 0.7 2.2 55.8 6510 77
1250 HXR 500LP4 1493 97.6 97.6 0.89 0.88 308 6.4 83 8953 0.7 2.3 63.7 7090 77
1400 HXR 560LK4 1494 97.7 97.7 0.90 0.88 351 6.7 95 10229 0.7 2.4 89.4 9410 82
1600 HXR 560LP4 1495 97.8 97.7 0.89 0.87 399 6.9 119 11500 0.7 2.5 107.7 10330 82
1800 HXR 560LS4 1495 97.9 97.9 0.89 0.87 440 7.1 127 12777 0.7 2.5 127.5 11350 82
2000 HXR 560LT4 1496 98.0 97.9 0.87 0.85 504 7.2 161 14298 0.7 2.4 139.7 11980 82

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 75


HV Non-sparking cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


160 HXR 355LA6 988 94.6 94.5 0.78 0.74 42 5.2 19 1546 1.1 2.0 5.4 1660 75
180 HXR 355LB6 988 94.9 94.9 0.79 0.74 46 5.4 21 1740 1.2 2.0 5.7 1700 75
200 HXR 355LC6 988 95.1 95.1 0.80 0.76 50 5.2 21 1934 1.2 1.9 6.3 1800 75
224 HXR 355LC6 988 95.3 95.3 0.80 0.76 57 5.4 24 2165 1.2 1.9 6.6 1850 75
250 HXR 355LD6 988 95.4 95.5 0.80 0.76 63 5.4 26 2416 1.2 1.9 7.3 1940 75
315 HXR 400LD6 992 96.1 96.1 0.83 0.79 86 5.9 32 3417 1.1 2.0 18.4 2710 75
355 HXR 400LF6 993 96.3 96.3 0.83 0.80 96 6.0 36 3848 1.1 2.0 20.9 2900 75
400 HXR 400LH6 993 96.4 96.4 0.83 0.79 109 6.1 41 4327 1.0 2.0 24.2 3140 75
500 HXR 450LF6 993 96.8 96.8 0.85 0.83 131 5.8 42 5388 1.0 2.0 34.9 3970 76
560 HXR 450LH6 993 96.8 96.9 0.86 0.83 146 5.9 47 6060 1.0 2.0 38.9 4200 76

3 630
800
900
HXR 450LK6
HXR 500LG6
HXR 500LJ6
993
994
994
97.0
97.1
97.2
97.0
97.2
97.3
0.86
0.86
0.87
0.83
0.84
0.85
165
207
228
6.0
6.0
5.9
53
66
68
6828
8648
9611
1.0
0.9
0.9
2.0
2.1
2.0
44.2
58.3
66.3
4540
5680
6080
76
77
77
1000 HXR 500LN6 994 97.4 97.4 0.86 0.84 256 6.1 83 10754 0.9 2.1 81.6 6860 77
1120 HXR 500LQ6 995 97.5 97.5 0.86 0.83 288 6.3 98 11998 0.9 2.2 89.1 7250 77
1400 HXR 500LS6 995 97.5 97.5 0.84 0.81 328 6.5 122 13431 0.9 2.3 97.9 7690 77
1400 HXR 560LN6 995 97.6 97.6 0.87 0.84 363 6.5 118 15348 0.8 2.3 142.1 10060 81
1600 HXR 560LR6 996 97.7 97.7 0.87 0.84 409 6.7 135 17262 0.8 2.4 169.5 11060 81
1800 HXR 560LU6 996 97.8 97.8 0.88 0.86 445 6.7 133 19171 0.7 2.4 207.4 12330 81

750 r/min = 8 poles 3000 V 50 Hz


180 HXR 400LB8 741 94.9 95.1 0.81 0.78 50 4.9 20 2577 0.9 1.9 15.2 2460 75
200 HXR 400LC8 741 95.1 95.3 0.82 0.78 55 5.0 21 2886 1.0 1.9 16.9 2580 75
224 HXR 400LE8 741 95.4 95.6 0.83 0.79 61 5.0 23 3221 1.0 1.9 19.4 2770 75
250 HXR 400LF8 742 95.5 95.7 0.83 0.79 68 5.0 26 3606 1.0 1.9 21.9 2950 75
280 HXR 400LH8 742 95.7 95.9 0.82 0.78 78 5.2 31 4052 1.0 2.0 24.3 3140 75
355 HXR 450LD8 743 95.9 96.0 0.83 0.80 96 5.3 35 5143 0.9 2.0 30.1 3610 78
400 HXR 450LE8 743 96.0 96.1 0.83 0.80 108 5.3 40 5786 0.9 2.0 31.5 3700 75
450 HXR 450LG8 743 96.2 96.3 0.83 0.80 120 5.5 44 6423 1.0 2.0 38.2 4100 75
500 HXR 450LH8 744 96.3 96.3 0.83 0.79 135 5.5 52 7192 0.9 2.0 40.9 4260 75
560 HXR 450LL8 744 96.4 96.4 0.82 0.79 153 5.7 60 8085 1.0 2.1 48.9 4720 75
630 HXR 500LF8 745 96.4 96.4 0.82 0.78 173 5.6 68 9101 0.9 2.0 55.2 5470 75
710 HXR 500LH8 745 96.5 96.5 0.82 0.78 194 5.6 75 10253 0.9 2.0 61.2 5780 75
800 HXR 500LK8 745 96.7 96.6 0.82 0.78 218 5.7 85 11532 0.9 2.0 69.2 6170 75
900 HXR 500LN8 745 96.6 96.6 0.82 0.79 242 5.5 90 12822 1.0 1.9 80.4 6740 75
1000 HXR 500LP8 745 96.8 96.8 0.83 0.80 268 5.7 97 14353 0.9 1.9 85.2 6910 75
1120 HXR 500LR8 745 96.9 96.9 0.82 0.79 301 5.7 113 16013 0.9 1.9 94.9 7430 75
1250 HXR 560LN8 746 97.3 97.3 0.82 0.78 339 5.9 137 17918 0.8 2.1 144.0 10050 78
1400 HXR 560LR8 747 97.5 97.4 0.82 0.78 387 6.1 154 20460 0.9 2.0 173.3 11020 78
1600 HXR 560LU8 747 97.6 97.5 0.81 0.77 440 6.0 180 23009 0.8 2.0 211.5 12390 78

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

76 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


140 HXR 400LC10 594 94.2 94.0 0.71 0.64 46 4.8 26 2572 1.0 2.0 16.9 2580 75
160 HXR 400LD10 594 94.4 94.2 0.72 0.66 51 4.8 27 2895 1.0 2.0 18.7 2710 75
180 HXR 400LE10 594 94.6 94.3 0.72 0.65 57 4.8 31 3215 1.0 2.0 19.8 2800 75
200 HXR 400LF10 594 94.7 94.6 0.72 0.66 63 4.8 34 3601 1.0 2.0 22.0 2970 75
224 HXR 400LH10 594 94.9 94.7 0.72 0.66 70 4.9 37 4018 1.0 2.0 24.5 3160 75
280 HXR 450LG10 595 95.8 95.8 0.76 0.70 83 5.2 41 5059 1.0 2.1 38.3 4090 75
315 HXR 450LJ10 595 95.9 96.0 0.76 0.71 93 5.2 45 5701 1.0 2.0 42.4 4330 75
355 HXR 450LK10 595 96.1 96.1 0.76 0.70 105 5.3 52 6422 1.0 2.1 46.5 4570 75
400 HXR 450LM10 595 96.2 96.1 0.75 0.70 120 5.4 60 7222 1.0 2.1 51.9 4900 75
450 HXR 500LH10 595 96.5 96.6 0.78 0.73 128 5.2 59 8026 0.9 2.1 62.9 5860 75
500
560
630
HXR 500LK10
HXR 500LM10
HXR 500LN10
595
595
595
96.5
96.6
96.6
96.6
96.7
96.7
0.79
0.79
0.79
0.74
0.74
0.75
142
159
179
5.1
5.2
5.0
62
70
75
8990
10113
11402
0.9
0.9
0.9
2.0
2.0
1.9
70.9
78.9
82.9
6220
6610
6820
75
75
75
3
710 HXR 500LP10 594 96.6 96.8 0.79 0.76 201 4.9 82 12851 0.9 1.9 86.9 7010 75
800 HXR 500LR10 595 96.7 96.8 0.79 0.75 227 5.2 98 14448 0.9 2.0 99.0 7600 75
900 HXR 560LN10 597 97.0 97.0 0.77 0.73 256 5.0 114 16006 0.7 1.9 145.4 10030 77
1000 HXR 560LQ10 597 97.1 97.0 0.77 0.72 289 5.3 135 17921 0.8 2.0 159.7 10520 77
1120 HXR 560LS10 597 97.1 97.1 0.78 0.74 318 5.1 139 20006 0.7 1.9 181.2 11270 77
1250 HXR 560LU10 597 97.2 97.0 0.75 0.69 368 6.0 187 22384 0.9 2.2 213.3 12390 77

500 r/min = 12 poles 3000 V 50 Hz


125 HXR 400LD12 494 93.6 93.4 0.68 0.61 42 4.3 25 2707 1.0 1.8 18.6 2710 75
140 HXR 400LE12 494 93.8 93.7 0.69 0.62 48 4.2 27 3094 1.0 1.8 20.3 2830 75
160 HXR 400LG12 494 94.0 93.9 0.70 0.64 53 4.1 29 3482 1.0 1.7 22.8 3030 75
180 HXR 400LH12 494 94.0 93.8 0.70 0.64 59 4.2 32 3867 1.0 1.8 25.4 3210 75
224 HXR 450LH12 495 94.9 94.7 0.71 0.65 72 4.3 38 4827 0.9 1.8 39.7 4180 75
250 HXR 450LJ12 494 95.0 94.9 0.72 0.66 79 4.2 40 5408 0.8 1.7 42.5 4370 75
280 HXR 450LL12 495 95.1 95.0 0.72 0.66 89 4.3 46 6081 0.9 1.8 49.3 4750 75
315 HXR 450LM12 495 95.1 95.0 0.71 0.66 101 4.3 53 6853 0.9 1.8 52.0 4910 75
355 HXR 500LJ12 495 95.5 95.4 0.71 0.65 113 4.4 60 7717 0.9 1.8 66.5 6040 75
400 HXR 500LL12 495 95.6 95.5 0.72 0.66 126 4.4 65 8683 0.9 1.8 72.6 6340 75
450 HXR 500LN12 495 95.7 95.6 0.72 0.67 139 4.4 71 9648 0.9 1.8 80.6 6740 75
500 HXR 500LQ12 495 95.6 95.5 0.72 0.66 157 4.4 81 10803 0.9 1.8 88.5 7100 75
560 HXR 500LR12 495 95.7 95.6 0.72 0.67 175 4.4 88 12157 0.9 1.8 92.6 7300 75
630 HXR 500LS12 495 95.8 95.7 0.72 0.66 199 4.5 103 13695 0.9 1.8 104.5 7890 75
710 HXR 560LM12 496 96.5 96.6 0.77 0.72 207 4.5 94 15407 0.7 1.9 133.9 9610 75
800 HXR 560LQ12 496 96.6 96.6 0.78 0.74 230 4.4 99 17335 0.7 1.8 158.8 10450 75
900 HXR 560LS12 496 96.7 96.7 0.77 0.72 257 4.8 119 19247 0.7 2.0 180.2 11210 75
1000 HXR 560LU12 497 96.9 96.8 0.75 0.69 296 5.1 148 21512 0.8 2.0 213.4 12320 75

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 77


HV Non-sparking cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


160 HXR 355LB2 2966 94.3 94.0 0.89 0.86 18 6.6 6 515 0.8 2.9 2.2 1670 85
180 HXR 355LB2 2962 94.3 94.2 0.90 0.88 20 6.2 6 580 0.7 2.7 2.2 1670 85
200 HXR 355LB2 2966 94.7 94.6 0.90 0.88 23 6.5 6 644 0.7 2.8 2.3 1720 85
280 HXR 400LC2 2976 95.6 95.4 0.89 0.87 36 6.7 9 1011 0.8 2.5 6.0 2540 82
315 HXR 400LC2 2981 95.9 95.8 0.91 0.89 39 6.9 10 1137 0.7 2.8 5.7 2530 82
355 HXR 400LD2 2981 96.2 96.1 0.92 0.91 44 6.9 10 1281 0.6 2.7 6.1 2640 82
500 HXR 450LF2 2984 96.5 96.3 0.93 0.91 60 7.4 13 1792 0.7 3.0 11.5 3870 85
560 HXR 450LH2 2984 96.7 96.6 0.93 0.92 67 7.2 14 2016 0.7 2.8 13.0 4170 85
690 HXR 500LG2 2988 96.6 96.3 0.91 0.90 77 7.3 19 2269 0.6 2.9 22.4 5570 86
710 HXR 500LH2 2987 96.7 96.5 0.92 0.91 86 7.3 19 2557 0.6 2.8 23.8 5760 86

3 800
900
1120
HXR 500LL2
HXR 500LN2
HXR 560LM2
2988
2987
2986
96.9
97.1
97.1
96.7
97.0
97.0
0.92
0.93
0.92
0.91
0.93
0.91
97
106
134
7.2
7.1
7.4
21
20
32
2877
3197
3997
0.6
0.6
0.6
2.8
2.7
3.0
27.0
30.3
46.2
6230
6690
9680
86
86
87
1250 HXR 560LN2 2989 97.3 97.2 0.92 0.90 151 7.4 36 4473 0.6 2.9 48.4 10030 87

1500 r/min = 4 poles 6000 V 50 Hz


160 HXR 355LA4 1487 94.6 94.3 0.82 0.77 20 5.6 8 1028 0.9 2.2 4.0 1720 77
180 HXR 355LA4 1486 94.7 94.5 0.81 0.77 23 5.4 9 1157 0.8 2.0 4.0 1730 77
200 HXR 355LA4 1486 94.9 94.8 0.83 0.79 25 5.3 10 1285 0.8 2.1 4.0 1730 77
224 HXR 355LC4 1486 95.0 94.9 0.82 0.79 28 5.3 11 1440 0.8 2.1 4.0 1730 77
250 HXR 355LC4 1486 95.3 95.3 0.83 0.80 30 5.5 11 1606 0.8 2.1 4.4 1830 77
355 HXR 400LC4 1486 96.0 96.0 0.86 0.84 41 5.2 13 2281 0.7 2.0 7.2 2530 76
400 HXR 400LD4 1487 96.2 96.2 0.86 0.83 47 5.5 15 2568 0.8 2.1 7.9 2660 76
450 HXR 400LD4 1490 96.5 96.5 0.87 0.85 52 6.2 16 2884 0.9 2.2 12.5 2720 76
500 HXR 400LE4 1490 96.6 96.6 0.88 0.86 57 6.1 17 3204 0.9 2.1 13.6 2850 76
560 HXR 450LE4 1492 96.9 96.8 0.87 0.84 72 6.6 24 4031 0.8 2.4 22.9 3810 77
630 HXR 450LG4 1492 97.0 97.0 0.88 0.86 80 6.4 24 4545 0.8 2.3 26.7 4130 77
710 HXR 450LJ4 1492 97.2 97.2 0.88 0.87 90 6.3 25 5121 0.8 2.2 30.3 4450 77
900 HXR 500LF4 1491 97.1 97.1 0.89 0.87 100 6.1 28 5763 0.8 2.2 40.0 5430 77
1000 HXR 500LG4 1492 97.2 97.2 0.89 0.87 112 6.2 32 6401 0.8 2.2 44.0 5690 77
1120 HXR 500LJ4 1493 97.3 97.3 0.88 0.86 125 6.6 37 7165 0.8 2.3 49.5 6080 77
1250 HXR 500LP4 1493 97.5 97.5 0.88 0.86 140 6.5 42 7994 0.8 2.3 63.3 7030 77
1400 HXR 560LM4 1495 97.7 97.6 0.89 0.86 178 6.9 54 10223 0.7 2.5 95.6 9670 82
1600 HXR 560LR4 1495 97.8 97.7 0.89 0.87 199 6.9 58 11499 0.7 2.5 122.4 10970 82
1800 HXR 560LT4 1496 97.9 97.8 0.88 0.86 224 7.0 68 12767 0.7 2.3 137.5 11730 82

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

78 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


125 HXR 355LC6 991 94.4 93.9 0.74 0.67 17 6.0 10 1204 1.0 2.8 4.8 1810 75
160 HXR 355LC6 988 94.5 94.4 0.78 0.73 21 5.0 10 1546 0.8 2.2 4.8 1810 75
180 HXR 355LD6 988 94.6 94.6 0.78 0.73 23 4.9 11 1740 0.7 2.1 4.8 1820 75
250 HXR 400LC6 991 95.7 95.7 0.82 0.77 35 5.9 15 2698 1.0 2.2 11.2 2490 75
280 HXR 400LC6 991 95.8 95.8 0.83 0.79 38 5.8 15 3037 1.0 2.1 11.8 2560 75
315 HXR 400LD6 991 96.0 96.0 0.82 0.78 43 5.8 18 3421 1.0 2.1 12.9 2680 75
355 HXR 400LF6 992 96.2 96.2 0.82 0.77 49 5.9 20 3852 1.0 2.2 14.5 2870 75
450 HXR 450LD6 992 96.3 96.4 0.85 0.82 53 6.0 19 4330 1.0 2.1 28.3 3520 76
500 HXR 450LF6 993 96.6 96.7 0.86 0.83 65 6.0 21 5388 1.1 2.0 35.0 3920 76
560 HXR 450LH6 993 96.7 96.8 0.86 0.83 73 6.0 24 6060 1.1 2.0 38.9 4160 76
630
710
800
HXR 450LK6
HXR 500LH6
HXR 500LJ6
994
994
994
96.9
97.0
97.0
96.9
96.9
97.1
0.84
0.83
0.84
0.81
0.80
0.81
84
95
107
6.4
5.8
5.7
30
36
38
6822
7685
8647
1.1
0.8
0.8
2.1
2.1
2.0
45.3
59.2
63.0
4520
5690
5890
76
77
77
3
900 HXR 500LK6 994 97.1 97.2 0.84 0.82 117 5.8 40 9609 0.9 2.0 69.0 6180 77
1000 HXR 500LN6 994 97.3 97.3 0.84 0.80 132 6.1 48 10755 0.9 2.1 80.4 6760 77
1120 HXR 500LR6 995 97.4 97.4 0.85 0.82 145 6.2 52 11995 0.8 2.2 92.5 7350 77
1250 HXR 560LM6 996 97.5 97.4 0.86 0.82 161 6.8 58 13423 0.8 2.5 134.5 9720 81
1400 HXR 560LR6 996 97.6 97.5 0.85 0.81 186 6.9 71 15334 0.8 2.5 161.0 10670 81
1600 HXR 560LU6 996 97.6 97.7 0.87 0.85 203 6.7 66 17260 0.8 2.4 204.3 12160 81

750 r/min = 8 poles 6000 V 50 Hz


180 HXR 400LC8 741 94.4 94.4 0.77 0.72 24 4.7 11 2319 1.0 1.9 11.7 2520 75
200 HXR 400LD8 742 94.7 94.7 0.76 0.71 27 4.8 13 2575 1.0 1.9 12.8 2650 75
224 HXR 400LE8 741 94.8 94.9 0.78 0.74 29 4.8 13 2887 1.0 1.9 13.9 2780 75
250 HXR 400LF8 741 94.9 95.1 0.80 0.76 32 4.7 13 3224 1.0 1.8 15.1 2900 75
315 HXR 450LD8 743 95.5 95.6 0.84 0.81 43 5.3 15 4565 0.9 2.0 30.1 3570 75
355 HXR 450LF8 743 95.8 95.8 0.83 0.80 48 5.4 18 5140 0.9 2.1 34.1 3810 75
400 HXR 450LG8 743 95.9 95.9 0.84 0.80 54 5.4 20 5783 0.9 2.0 36.8 3970 75
450 HXR 450LK8 744 96.1 96.1 0.84 0.80 60 5.6 22 6420 1.0 2.1 46.3 4530 75
630 HXR 500LJ8 745 96.3 96.2 0.83 0.80 85 5.9 33 9102 0.9 2.2 67.0 5970 75
710 HXR 500LK8 745 96.4 96.3 0.83 0.80 96 5.9 37 10257 0.9 2.2 69.1 6080 75
800 HXR 500LL8 745 96.4 96.4 0.84 0.80 107 5.7 40 11542 0.9 2.1 73.1 6270 75
900 HXR 500LP8 745 96.6 96.5 0.84 0.80 119 5.9 45 12819 0.9 2.2 85.0 6860 75
1120 HXR 560LM8 746 97.1 97.2 0.82 0.78 151 5.7 59 16002 0.8 2.0 136.9 9700 78
1250 HXR 560LQ8 747 97.2 97.2 0.81 0.76 172 6.6 76 17907 1.0 2.4 158.1 10390 78
1400 HXR 560LU8 747 97.4 97.2 0.79 0.74 199 6.4 93 20454 0.9 2.4 206.0 12110 78

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 79


HV Non-sparking cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


200 HXR 450LD10 595 95.1 95.0 0.74 0.68 31 5.3 16 3596 1.0 2.1 30.1 3550 75
224 HXR 450LE10 595 95.2 95.2 0.75 0.69 34 5.2 17 4015 1.0 2.1 32.8 3710 75
250 HXR 450LF10 595 95.3 95.4 0.76 0.70 37 5.2 18 4497 1.0 2.1 35.6 3860 75
280 HXR 450LG10 595 95.5 95.5 0.76 0.70 42 5.2 21 5059 1.0 2.1 38.3 4030 75
315 HXR 450LJ10 594 95.6 95.7 0.78 0.72 46 5.2 21 5703 1.0 2.0 43.8 4340 75
355 HXR 450LK10 595 95.7 95.7 0.76 0.71 53 5.3 26 6422 1.1 2.1 46.5 4500 75
450 HXR 500LJ10 594 96.2 96.3 0.78 0.74 64 5.0 28 8038 1.0 1.9 64.6 5890 75
500 HXR 500LL10 594 96.3 96.4 0.79 0.74 71 5.1 31 9001 1.0 1.9 74.6 6370 75
560 HXR 500LM10 595 96.3 96.3 0.79 0.75 80 5.1 34 10116 0.9 2.0 78.9 6540 75
630 HXR 500LP10 595 96.3 96.4 0.79 0.75 89 5.0 37 11405 0.9 1.9 84.9 6830 75

3 710
900
1000
HXR 500LQ10
HXR 560LN10
HXR 560LR10
594
597
597
96.4
96.9
97.0
96.5
96.8
96.8
0.80
0.78
0.75
0.76
0.73
0.70
100
128
147
4.9
5.0
5.8
41
57
75
12852
16006
17910
0.9
0.7
0.9
1.9
1.9
2.2
90.9
145.4
174.0
7120
9910
10900
75
77
77
1120 HXR 560LU10 597 97.0 96.9 0.77 0.72 161 5.7 77 19991 0.8 2.1 209.7 12070 77

500 r/min = 12 poles 6000 V 50 Hz


140 HXR 450LF12 496 94.0 93.4 0.62 0.55 26 4.2 17 3082 0.8 2.0 27.1 3970 75
160 HXR 450LF12 494 94.2 94.0 0.67 0.61 30 3.6 17 3863 0.6 1.6 27.1 3970 75
200 HXR 450LG12 495 94.4 94.3 0.71 0.65 32 4.3 17 4324 0.9 1.8 38.4 4040 75
224 HXR 450LJ12 495 94.6 94.4 0.71 0.65 36 4.3 19 4824 0.8 1.8 43.8 4360 75
250 HXR 450LK12 495 94.7 94.5 0.71 0.66 40 4.3 21 5405 0.9 1.8 46.6 4520 75
280 HXR 450LL12 495 94.8 94.6 0.72 0.66 45 4.3 23 6081 0.9 1.8 49.3 4680 75
315 HXR 500LJ12 495 95.1 94.9 0.71 0.65 50 4.5 27 6851 0.9 1.9 64.6 5890 75
355 HXR 500LK12 495 95.0 94.8 0.71 0.66 57 4.5 30 7720 0.9 1.9 68.6 6080 75
400 HXR 500LL12 495 95.1 95.0 0.72 0.66 63 4.5 33 8687 0.9 1.8 74.6 6380 75
450 HXR 500LN12 495 95.3 95.1 0.72 0.67 70 4.5 36 9651 0.9 1.8 82.6 6770 75
500 HXR 500LQ12 495 95.3 95.1 0.72 0.66 79 4.5 41 10806 0.9 1.8 90.5 7160 75
630 HXR 560LM12 496 96.3 96.3 0.77 0.73 92 4.6 42 13669 0.7 1.9 137.5 9600 75
710 HXR 560LP12 496 96.4 96.3 0.76 0.70 106 5.1 54 15388 0.8 2.1 151.7 10060 75
800 HXR 560LS12 497 96.5 96.5 0.76 0.70 118 5.2 59 17308 0.8 2.2 180.2 11060 75
900 HXR 560LU12 497 96.7 96.6 0.77 0.72 130 4.8 60 19215 0.8 1.9 209.8 12020 75

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

80 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


630 AMA 400L2A 2977 95.3 95.1 0.86 0.84 148 5.4 43 2021 0.6 2.3 7.1 3000 85
710 AMA 400L2A 2977 95.6 95.5 0.86 0.85 165 5.5 46 2277 0.6 2.3 7.5 3130 85
800 AMA 400L2A 2977 95.7 95.7 0.87 0.86 184 5.5 47 2566 0.6 2.3 8.0 3220 85
900 AMA 400L2A 2978 96.0 96.0 0.87 0.86 206 5.6 52 2886 0.6 2.3 8.5 3340 85
1000 AMA 400L2A 2979 96.2 96.2 0.87 0.85 230 5.8 61 3206 0.7 2.4 8.9 3450 85
1120 AMA 450L2A 2979 96.2 96.1 0.86 0.85 259 5.1 69 3590 0.5 2.2 11.6 4270 86
1250 AMA 450L2A 2980 96.4 96.3 0.85 0.83 295 5.1 84 4005 0.5 2.2 12.3 4420 86
1400 AMA 450L2A 2982 96.6 96.5 0.85 0.83 328 5.4 93 4484 0.5 2.3 13.8 4710 86
1600 AMA 500L2A 2983 96.5 96.5 0.89 0.89 357 5.0 80 5121 0.4 2.1 21.1 5370 87
1800 AMA 500L2A 2986 96.7 96.6 0.88 0.86 409 5.5 113 5757 0.5 2.3 22.4 5520 87
2000
2240
AMA 500L2A
AMA 500L2A

1500 r/min = 4 poles


2983
2986
96.8
97.0
96.8
97.0
0.90
0.88
0.89
0.87

3000 V 50 Hz
443
504
5.0
5.5
94
128
6402
7164
0.4
0.5
2.1
2.2
23.8
26.3
5710
6090
87
87 3
630 AMA 400L4A 1486 95.3 95.3 0.88 0.86 145 5.0 41 4049 0.6 2.0 15.6 3050 79
710 AMA 400L4A 1488 95.6 95.6 0.86 0.83 166 5.6 56 4558 0.7 2.3 16.6 3150 79
800 AMA 400L4A 1487 95.7 95.7 0.87 0.84 186 5.5 60 5136 0.7 2.2 17.6 3220 79
900 AMA 400L4A 1488 95.9 95.9 0.86 0.83 210 5.5 69 5778 0.7 2.2 18.5 3330 79
1000 AMA 400L4A 1488 96.1 96.1 0.87 0.84 231 5.8 75 6417 0.8 2.3 20.5 3520 79
1120 AMA 400L4A 1487 96.1 96.2 0.87 0.85 257 5.4 75 7191 0.7 2.2 21.3 3550 79
1250 AMA 450L4A 1488 96.0 96.0 0.87 0.85 288 5.5 85 8023 0.7 2.1 31.5 4210 81
1400 AMA 450L4A 1488 96.2 96.3 0.88 0.86 318 5.5 87 8984 0.7 2.1 35.0 4470 81
1600 AMA 450L4A 1488 96.4 96.5 0.88 0.86 364 5.6 102 10265 0.8 2.1 38.4 4720 81
1800 AMA 500L4A 1491 96.3 96.3 0.89 0.87 406 5.5 106 11531 0.7 2.0 55.9 5570 82
2000 AMA 500L4A 1491 96.5 96.5 0.88 0.87 453 5.5 121 12811 0.7 2.0 58.8 5730 82
2240 AMA 500L4A 1491 96.6 96.6 0.88 0.87 506 5.7 135 14344 0.7 2.1 64.6 6030 82
2500 AMA 500L4A 1490 96.7 96.8 0.89 0.89 556 5.5 125 16024 0.8 2.0 70.2 6380 82

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 81


HV Non-sparking modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


450 AMA 400L6A 988 95.0 95.2 0.84 0.81 109 5.0 40 4350 0.8 2.0 17.0 2950 78
500 AMA 400L6A 989 95.2 95.3 0.81 0.77 124 5.0 51 4829 0.7 2.0 18.1 3050 78
560 AMA 400L6A 988 95.3 95.4 0.83 0.80 136 5.0 51 5411 0.8 1.9 19.4 3130 78
630 AMA 400L6A 990 95.5 95.6 0.82 0.78 155 5.2 62 6080 0.8 2.0 21.7 3320 78
710 AMA 400L6A 990 95.6 95.7 0.81 0.77 175 5.3 73 6851 0.8 2.0 22.9 3410 78
800 AMA 400L6A 990 95.8 95.9 0.83 0.79 193 5.4 74 7720 0.8 2.0 25.4 3600 78
900 AMA 450L6A 991 96.0 96.2 0.86 0.83 210 5.2 67 8670 0.6 2.0 39.8 4220 79
1000 AMA 450L6A 992 96.2 96.3 0.85 0.82 236 5.4 82 9629 0.7 2.0 42.0 4340 79
1120 AMA 450L6A 991 96.1 96.3 0.86 0.84 260 5.4 80 10792 0.7 2.1 44.4 4450 79
1250 AMA 450L6A 992 96.4 96.5 0.84 0.81 296 5.5 104 12033 0.7 2.1 48.6 4700 79

3 1400
1600
1800
AMA 500L6A
AMA 500L6A
AMA 500L6A
992
993
992
96.5
96.6
96.6
96.6
96.7
96.8
0.87
0.87
0.88
0.85
0.85
0.87
320
367
406
5.6
5.8
5.5
95
115
106
13474
15393
17328
0.7
0.8
0.7
2.1
2.2
2.0
68.5
75.6
83.0
5560
5850
6140
79
79
79
2000 AMA 500L6A 993 96.8 96.9 0.86 0.84 461 5.8 149 19225 0.7 2.2 91.0 6450 79

750 r/min = 8 poles 3000 V 50 Hz


280 AMA 400L8A 741 94.8 94.8 0.82 0.78 69 5.2 28 3611 0.9 2.1 19.1 2920 77
315 AMA 400L8A 740 94.7 94.9 0.84 0.81 76 4.9 28 4066 0.9 1.9 20.5 3000 77
355 AMA 400L8A 741 95.0 95.1 0.83 0.79 87 5.3 35 4576 1.0 2.1 21.9 3100 77
400 AMA 400L8A 740 95.1 95.3 0.83 0.80 97 5.2 37 5158 0.9 2.1 23.3 3200 77
450 AMA 400L8A 740 95.1 95.3 0.83 0.80 109 5.2 41 5804 0.9 2.0 24.8 3290 77
500 AMA 400L8A 741 95.3 95.4 0.83 0.79 121 5.3 47 6447 1.0 2.1 26.2 3380 77
560 AMA 400L8A 741 95.3 95.5 0.84 0.80 135 5.2 50 7221 1.0 2.0 29.0 3570 77
630 AMA 450L8A 743 95.7 95.8 0.81 0.77 155 5.5 66 8097 0.8 2.2 42.7 4050 77
710 AMA 450L8A 742 95.9 96.1 0.85 0.82 167 5.4 58 9136 0.8 2.0 48.3 4300 77
800 AMA 450L8A 742 96.0 96.2 0.85 0.83 188 5.4 63 10293 0.8 2.0 53.7 4540 77
900 AMA 450L8A 743 96.2 96.4 0.85 0.82 211 5.7 74 11572 0.9 2.2 59.1 4790 77
1000 AMA 500L8A 742 96.1 96.4 0.87 0.85 231 5.0 67 12870 0.7 2.0 79.5 5500 77
1120 AMA 500L8A 743 96.4 96.6 0.87 0.85 258 5.4 79 14394 0.7 2.1 89.0 5810 77
1250 AMA 500L8A 743 96.4 96.6 0.86 0.83 291 5.5 96 16065 0.8 2.1 96.7 6080 77
1400 AMA 500L8A 743 96.4 96.7 0.87 0.84 323 5.6 101 17997 0.8 2.1 105.9 6380 77

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

82 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


200 AMA 400L10A 592 93.6 93.6 0.73 0.67 56 4.5 30 3227 0.8 2.0 17.6 2820 76
224 AMA 400L10A 592 93.8 93.8 0.75 0.69 61 4.4 31 3615 0.7 1.9 19.1 2920 76
250 AMA 400L10A 592 94.0 94.0 0.75 0.70 68 4.4 33 4035 0.7 1.9 20.5 3020 76
280 AMA 400L10A 592 94.1 94.2 0.75 0.70 76 4.4 38 4517 0.8 1.9 21.9 3110 76
315 AMA 400L10A 593 94.3 94.2 0.74 0.67 87 4.8 46 5071 0.9 2.0 24.8 3290 76
355 AMA 400L10A 593 94.5 94.5 0.75 0.69 97 4.6 49 5718 0.9 1.9 26.3 3400 76
400 AMA 400L10A 593 94.7 94.5 0.73 0.67 111 4.9 59 6437 0.9 2.0 29.1 3590 76
450 AMA 450L10A 592 94.9 95.1 0.82 0.78 112 4.7 45 7254 0.8 1.9 42.7 4040 76
500 AMA 450L10A 593 95.1 95.2 0.81 0.77 125 4.9 52 8055 0.9 2.0 45.4 4160 76
560 AMA 450L10A 593 95.2 95.4 0.82 0.78 139 4.9 56 9021 0.9 2.0 50.8 4400 76
630
710
800
AMA 450L10A
AMA 500L10A
AMA 500L10A
593
595
595
95.4
95.8
95.9
95.5
95.8
95.9
0.82
0.81
0.82
0.79
0.76
0.77
154
177
197
4.9
5.6
5.3
60
79
82
10149
11397
12849
0.9
0.8
0.8
2.0
2.2
2.1
58.9
80.2
84.7
4770
5450
5600
76
76
76
3
900 AMA 500L10A 594 96.0 96.1 0.83 0.80 216 5.5 83 14457 0.8 2.1 98.4 6060 76
1000 AMA 500L10A 594 96.0 96.2 0.85 0.82 237 5.2 84 16073 0.8 2.0 107.4 6350 76

500 r/min = 12 poles 3000 V 50 Hz


140 AMA 400L12A 493 92.5 92.2 0.70 0.64 41 4.1 23 2711 0.8 1.9 19.2 2910 76
160 AMA 400L12A 493 92.7 92.5 0.72 0.66 46 4.0 25 3101 0.8 1.8 20.6 3010 76
180 AMA 400L12A 493 92.9 92.7 0.72 0.66 52 4.0 27 3488 0.8 1.8 22.1 3100 76
200 AMA 400L12A 493 93.1 92.8 0.71 0.65 58 4.0 31 3874 0.8 1.9 23.5 3200 76
224 AMA 400L12A 493 93.2 92.8 0.70 0.64 66 4.2 37 4335 0.9 2.0 24.9 3290 76
250 AMA 400L12A 493 93.1 92.9 0.71 0.65 72 4.1 39 4842 0.8 1.9 26.4 3370 76
315 AMA 450L12A 495 94.5 94.3 0.72 0.65 90 4.7 51 6082 0.9 2.1 42.9 4020 76
355 AMA 450L12A 495 94.6 94.4 0.71 0.64 101 4.7 58 6855 0.9 2.1 45.6 4150 76
400 AMA 450L12A 494 94.7 94.6 0.73 0.67 111 4.6 60 7726 0.8 2.0 51.0 4380 76
450 AMA 450L12A 494 94.6 94.6 0.74 0.69 123 4.4 63 8698 0.8 1.9 53.7 4480 76
500 AMA 450L12A 494 94.8 94.7 0.74 0.68 137 4.6 72 9659 0.8 2.0 59.0 4720 76
560 AMA 500L12A 494 95.2 95.2 0.77 0.72 148 4.5 70 10816 0.7 1.9 79.9 5440 76
630 AMA 500L12A 495 95.3 95.3 0.77 0.72 166 4.5 78 12165 0.7 1.9 88.9 5750 76
710 AMA 500L12A 494 95.4 95.5 0.77 0.72 186 4.4 85 13715 0.7 1.8 93.3 5930 76
800 AMA 500L12A 495 95.5 95.5 0.77 0.72 209 4.6 98 15444 0.7 1.9 106.8 6350 76

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 83


HV Non-sparking modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


630 AMA 400L2A 2979 95.0 94.9 0.88 0.86 73 5.7 20 2020 0.6 2.4 7.5 3050 85
710 AMA 400L2A 2977 95.3 95.3 0.87 0.85 83 5.5 23 2277 0.6 2.3 7.5 3070 85
800 AMA 400L2A 2977 95.6 95.6 0.88 0.86 92 5.5 24 2566 0.6 2.3 8.0 3190 85
900 AMA 400L2A 2978 95.8 95.8 0.87 0.86 103 5.5 26 2886 0.6 2.3 8.5 3300 85
1000 AMA 400L2A 2979 96.0 96.0 0.87 0.85 115 5.8 31 3206 0.7 2.4 8.9 3410 85
1120 AMA 450L2A 2979 96.1 96.0 0.86 0.85 130 5.1 35 3590 0.5 2.2 11.6 4220 86
1250 AMA 450L2A 2980 96.3 96.2 0.84 0.82 148 5.3 43 4005 0.5 2.2 12.3 4350 86
1600 AMA 500L2A 2986 96.4 96.3 0.87 0.85 183 5.4 52 5118 0.4 2.2 21.0 5250 87
1800 AMA 500L2A 2986 96.6 96.6 0.88 0.86 204 5.5 56 5757 0.5 2.3 22.4 5460 87
2000 AMA 500L2A 2986 96.8 96.7 0.87 0.85 228 5.5 64 6396 0.5 2.3 23.7 5640 87

3 2240 AMA 500L2A

1500 r/min = 4 poles


2986 96.9 96.9 0.88 0.87

6000 V 50 Hz
252 5.5 64 7164 0.5 2.2 26.3 6010 87

630 AMA 400L4A 1487 94.9 95.0 0.89 0.87 72 5.1 20 4046 0.6 2.0 16.6 3060 79
710 AMA 400L4A 1487 95.3 95.4 0.86 0.83 84 5.5 29 4558 0.7 2.2 16.5 3080 79
800 AMA 400L4A 1487 95.5 95.6 0.86 0.84 93 5.4 31 5136 0.7 2.2 17.5 3180 79
900 AMA 400L4A 1487 95.7 95.8 0.86 0.83 105 5.5 34 5778 0.7 2.2 18.5 3280 79
1250 AMA 450L4A 1488 95.9 95.9 0.87 0.85 144 5.5 43 8023 0.7 2.1 31.5 4150 81
1400 AMA 450L4A 1488 96.1 96.2 0.88 0.86 160 5.5 45 8985 0.7 2.0 34.9 4410 81
1600 AMA 500L4A 1491 96.0 96.0 0.88 0.87 181 5.5 49 10249 0.7 2.0 52.8 5310 82
1800 AMA 500L4A 1491 96.2 96.2 0.89 0.87 203 5.6 53 11531 0.7 2.0 55.8 5470 82
2000 AMA 500L4A 1491 96.3 96.4 0.88 0.86 227 5.5 62 12811 0.7 2.1 58.6 5630 82
2240 AMA 500L4A 1491 96.5 96.6 0.88 0.86 255 5.6 70 14344 0.7 2.1 64.2 5950 82

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

84 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


450 AMA 400L6A 988 94.9 95.0 0.84 0.81 54 4.7 19 4351 0.7 1.9 15.2 3000 78
500 AMA 400L6A 989 94.9 95.0 0.82 0.78 62 5.1 26 4829 0.8 2.0 18.1 2980 78
560 AMA 400L6A 988 95.0 95.2 0.83 0.80 68 5.1 25 5410 0.8 2.0 19.4 3070 78
630 AMA 400L6A 990 95.3 95.4 0.82 0.78 77 5.3 31 6080 0.8 2.0 21.7 3260 78
710 AMA 400L6A 990 95.4 95.5 0.82 0.77 88 5.3 37 6851 0.8 2.0 22.9 3360 78
800 AMA 450L6A 991 95.7 95.9 0.86 0.84 93 5.3 30 7707 0.7 2.0 37.6 4030 79
900 AMA 450L6A 991 95.9 96.0 0.86 0.84 105 5.3 34 8670 0.7 2.0 39.8 4160 79
1000 AMA 450L6A 992 96.1 96.2 0.85 0.82 118 5.5 41 9629 0.7 2.1 42.0 4290 79
1125 AMA 450L6A 991 96.0 96.3 0.86 0.84 130 5.4 40 10840 0.7 2.1 44.4 4400 79
1250 AMA 500L6A 992 96.3 96.4 0.87 0.85 161 5.5 48 13475 0.7 2.0 68.3 5450 79
1400
1600
1800
AMA 500L6A
AMA 500L6A
AMA 500L6A
992
992
993
96.4
96.5
96.6
96.6
96.7
96.8
0.88
0.89
0.87
0.86
0.87
0.84
182
203
230
5.6
5.5
6.1
51
53
74
15400
17328
19224
0.8
0.8
0.8
2.0
2.0
2.3
75.6
83.0
91.6
5740
6040
6380
79
79
79
3
750 r/min = 8 poles 6000 V 50 Hz
280 AMA 400L8A 740 94.1 94.3 0.83 0.79 35 5.1 14 3611 0.9 2.1 19.1 2860 77
315 AMA 400L8A 740 94.2 94.5 0.84 0.81 38 4.8 14 4067 0.8 1.9 20.5 2960 77
355 AMA 400L8A 741 94.5 94.7 0.83 0.79 44 5.3 17 4577 0.9 2.1 21.9 3050 77
400 AMA 400L8A 740 94.6 94.9 0.83 0.80 49 5.1 19 5159 0.9 2.0 23.3 3140 77
450 AMA 400L8A 740 94.7 95.0 0.84 0.80 55 5.1 21 5805 0.9 2.0 24.8 3240 77
500 AMA 400L8A 741 94.9 95.1 0.83 0.80 61 5.2 24 6447 1.0 2.0 26.2 3330 77
560 AMA 450L8A 743 95.3 95.4 0.82 0.77 69 5.3 29 7198 0.8 2.1 40.0 3880 77
630 AMA 450L8A 743 95.4 95.6 0.81 0.77 78 5.4 33 8098 0.8 2.1 42.7 4000 77
710 AMA 450L8A 742 95.6 95.9 0.85 0.82 84 5.3 29 9136 0.8 2.1 48.3 4240 77
800 AMA 450L8A 742 95.8 96.0 0.86 0.83 94 5.4 32 10293 0.8 2.0 53.7 4480 77
900 AMA 500L8A 742 95.8 96.1 0.86 0.84 105 5.0 32 11585 0.7 2.0 70.6 5130 77
1000 AMA 500L8A 742 95.9 96.3 0.87 0.85 115 5.0 33 12870 0.7 2.0 79.5 5430 77
1120 AMA 500L8A 743 96.1 96.4 0.87 0.85 129 5.3 39 14395 0.7 2.1 89.0 5700 77
1250 AMA 500L8A 743 96.2 96.4 0.86 0.83 146 5.4 48 16062 0.8 2.0 96.7 5990 77

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 85


HV Non-sparking modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


200 AMA 400L10A 592 93.2 93.0 0.70 0.63 30 4.0 17 3225 0.7 2.0 15.4 2970 76
224 AMA 400L10A 591 93.1 93.2 0.72 0.66 32 3.7 17 3618 0.6 1.7 15.4 2970 76
250 AMA 400L10A 593 93.6 93.4 0.72 0.65 36 4.6 20 4026 0.8 2.1 20.9 3150 76
280 AMA 400L10A 592 93.6 93.6 0.74 0.68 39 4.2 20 4516 0.7 1.9 20.9 3150 76
315 AMA 400L10A 593 93.9 93.8 0.74 0.68 44 4.7 23 5071 0.9 2.0 24.8 3240 76
400 AMA 450L10A 592 94.4 94.7 0.82 0.78 50 4.7 20 6448 0.8 1.9 40.1 3850 76
450 AMA 450L10A 592 94.5 94.8 0.82 0.78 56 4.7 22 7254 0.8 1.9 42.7 3970 76
500 AMA 450L10A 593 94.7 94.9 0.81 0.77 62 4.9 26 8055 0.9 2.0 45.4 4090 76
560 AMA 450L10A 593 94.9 95.1 0.82 0.78 69 4.9 28 9021 0.9 2.0 50.8 4330 76
630 AMA 500L10A 595 95.5 95.5 0.82 0.77 78 5.5 33 10115 0.8 2.2 75.8 5230 76

3 710
800
900
AMA 500L10A
AMA 500L10A
AMA 500L10A
594
594
594
95.5
95.7
95.9
95.6
95.9
96.0
0.83
0.83
0.84
0.79
0.79
0.80
86
97
108
5.4
5.3
5.5
35
37
41
11405
12856
14457
0.8
0.8
0.8
2.2
2.1
2.1
80.4
84.9
98.4
5380
5560
6010
76
76
76
1000 AMA 500L10A 594 95.8 96.0 0.84 0.81 119 5.3 44 16067 0.8 2.1 107.4 6270 76

500 r/min = 12 poles 6000 V 50 Hz


140 AMA 400L12A 494 91.6 90.9 0.67 0.59 22 4.1 14 2708 0.9 2.1 19.6 3050 76
160 AMA 400L12A 493 91.7 91.4 0.70 0.63 24 3.8 14 3101 0.7 1.8 19.6 3050 76
180 AMA 400L12A 493 92.0 91.6 0.69 0.63 27 3.8 16 3487 0.8 1.8 20.9 3140 76
200 AMA 400L12A 492 92.1 91.9 0.70 0.65 30 3.7 16 3879 0.7 1.7 22.1 3240 76
224 AMA 400L12A 493 92.3 92.0 0.71 0.64 33 4.1 19 4336 0.8 1.9 24.9 3220 76
250 AMA 450L12A 495 93.8 93.6 0.72 0.65 40 4.8 23 5406 0.9 2.2 40.2 3850 76
280 AMA 450L12A 495 94.0 93.8 0.72 0.65 45 4.8 25 6083 0.9 2.2 42.9 3970 76
315 AMA 450L12A 495 94.1 94.0 0.72 0.65 50 4.8 29 6855 0.9 2.1 45.6 4090 76
355 AMA 450L12A 494 94.3 94.2 0.74 0.67 55 4.7 30 7726 0.9 2.1 51.0 4320 76
400 AMA 450L12A 494 94.0 94.1 0.75 0.69 61 4.5 31 8699 0.8 1.9 53.7 4410 76
450 AMA 500L12A 495 94.9 94.9 0.76 0.70 67 4.7 34 9650 0.8 2.0 75.2 5250 76
500 AMA 500L12A 494 94.8 94.9 0.77 0.72 73 4.6 35 10816 0.8 1.9 79.9 5370 76
560 AMA 500L12A 495 95.0 95.0 0.78 0.72 82 4.7 39 12164 0.8 2.0 88.9 5670 76
630 AMA 500L12A 494 95.2 95.3 0.78 0.73 92 4.6 42 13715 0.8 1.9 93.3 5850 76
710 AMA 500L12A 495 95.3 95.4 0.78 0.72 104 4.8 49 15444 0.8 2.0 106.8 6290 76

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

86 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


710 AMA 400L2L 2973 95.9 96.1 0.86 0.84 165 5.1 45 2280 0.6 2.2 6.1 2880 82
800 AMA 400L2L 2974 96.1 96.3 0.88 0.86 183 5.1 45 2568 0.6 2.2 6.5 2980 82
900 AMA 400L2L 2974 96.2 96.4 0.88 0.87 204 5.2 47 2890 0.6 2.1 7.0 3070 82
1000 AMA 400L2L 2977 96.4 96.6 0.89 0.87 225 5.4 53 3208 0.6 2.2 7.3 3190 82
1120 AMA 400L2L 2976 96.5 96.7 0.88 0.87 253 5.6 60 3593 0.7 2.3 7.9 3310 82
1250 AMA 450L2L 2977 96.6 96.7 0.88 0.86 283 4.9 69 4010 0.5 2.1 12.1 4080 83
1400 AMA 450L2L 2978 96.7 96.9 0.86 0.85 323 4.9 84 4489 0.5 2.1 12.8 4220 83
1600 AMA 450L2L 2979 96.9 97.1 0.87 0.86 367 5.1 92 5129 0.5 2.1 14.3 4520 83
1800 AMA 500L2L 2986 97.0 97.0 0.85 0.82 421 5.5 141 5756 0.5 2.3 19.7 5110 84
2000 AMA 500L2L 2984 97.0 97.1 0.89 0.87 447 5.2 112 6400 0.5 2.2 21.1 5300 84
2240
2500
AMA 500L2L
AMA 500L2L

1500 r/min = 4 poles


2987
2984
97.3
97.3
97.2
97.4
0.84
0.89
0.81
0.88

3000 V 50 Hz
526
553
5.8
5.3
183
126
7162
8000
0.5
0.5
2.4
2.2
22.4
25.1
5500
5880
84
84 3
710 AMA 400L4L 1488 95.8 95.9 0.80 0.75 178 5.4 80 4556 0.7 2.3 14.0 2850 79
800 AMA 400L4L 1488 96.0 96.1 0.81 0.77 197 5.4 82 5134 0.7 2.3 15.0 2960 79
900 AMA 400L4L 1488 96.2 96.3 0.82 0.77 221 5.5 91 5775 0.7 2.3 16.0 3070 79
1000 AMA 400L4L 1487 96.2 96.4 0.85 0.83 234 5.2 78 6423 0.7 2.1 17.0 3160 79
1120 AMA 400L4L 1487 96.3 96.5 0.84 0.81 265 5.4 94 7192 0.7 2.2 18.0 3260 79
1400 AMA 450L4L 1486 96.2 96.5 0.87 0.86 321 4.9 85 8996 0.7 1.9 29.4 4000 80
1600 AMA 450L4L 1486 96.4 96.7 0.88 0.88 361 5.0 86 10281 0.7 1.9 33.0 4260 80
1800 AMA 450L4L 1487 96.6 96.9 0.89 0.88 404 5.4 99 11559 0.8 2.0 36.5 4520 80
2000 AMA 500L4L 1490 96.6 96.8 0.89 0.88 450 5.0 106 12822 0.6 1.8 53.5 5330 81
2240 AMA 500L4L 1490 96.7 96.9 0.88 0.88 505 5.0 121 14360 0.6 1.8 56.4 5490 81
2500 AMA 500L4L 1490 96.8 97.0 0.89 0.88 559 5.3 133 16020 0.7 1.9 62.6 5790 81
2800 AMA 500L4L 1490 97.0 97.2 0.89 0.89 621 5.5 142 17940 0.7 2.0 68.6 6140 81

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 87


HV Non-sparking modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


500 AMA 400L6L 986 95.1 95.5 0.84 0.82 120 4.5 40 4841 0.7 1.8 15.5 2780 77
560 AMA 400L6L 987 95.4 95.6 0.84 0.80 135 4.9 49 5416 0.8 2.0 16.7 2880 77
630 AMA 400L6L 987 95.3 95.7 0.85 0.82 150 4.7 50 6096 0.7 1.9 18.0 2960 77
710 AMA 400L6L 988 95.6 95.9 0.85 0.82 169 5.2 59 6861 0.8 2.1 20.4 3150 77
800 AMA 400L6L 988 95.7 96.0 0.84 0.81 192 5.3 69 7729 0.9 2.1 21.6 3250 77
1000 AMA 450L6L 992 96.3 96.4 0.81 0.77 245 5.4 101 9626 0.7 2.1 37.4 4020 78
1120 AMA 450L6L 991 96.3 96.6 0.86 0.84 260 5.2 81 10796 0.7 2.0 40.0 4140 78
1250 AMA 450L6L 990 96.2 96.6 0.87 0.85 289 4.9 80 12059 0.7 1.9 42.3 4250 78
1400 AMA 450L6L 990 96.3 96.7 0.87 0.86 322 5.0 89 13502 0.7 2.0 46.8 4490 78
1600 AMA 500L6L 991 96.5 96.8 0.88 0.87 362 5.2 94 15418 0.7 1.9 65.5 5300 79

3 1800
2000
AMA 500L6L
AMA 500L6L

750 r/min = 8 poles


992
991
96.6
96.7
96.9
97.0
0.88
0.89
0.86
0.88

3000 V 50 Hz
408
446
5.6
5.4
113
105
17334
19271
0.8
0.8
2.1
2.0
72.8
80.2
5570
5890
79
79

315 AMA 400L8L 738 94.5 94.9 0.83 0.81 77 4.6 27 4075 0.9 1.8 17.5 2730 75
355 AMA 400L8L 739 94.7 95.0 0.83 0.80 86 4.7 31 4585 0.8 1.9 19.0 2830 75
400 AMA 400L8L 739 94.9 95.3 0.84 0.81 97 4.8 35 5166 0.9 1.9 20.4 2930 75
450 AMA 400L8L 739 95.1 95.4 0.84 0.81 108 4.7 37 5814 0.8 1.8 21.8 3040 75
500 AMA 400L8L 739 95.1 95.5 0.84 0.82 120 4.7 41 6460 0.9 1.8 23.3 3120 75
560 AMA 400L8L 739 95.2 95.5 0.84 0.81 135 4.8 47 7233 0.9 1.8 24.7 3220 75
630 AMA 400L8L 739 95.2 95.6 0.84 0.82 151 4.7 50 8139 0.9 1.8 27.5 3400 75
710 AMA 450L8L 742 95.8 96.0 0.83 0.80 171 5.3 66 9137 0.8 2.1 40.7 3850 76
800 AMA 450L8L 741 95.8 96.2 0.86 0.84 188 4.8 58 10310 0.7 1.8 46.1 4090 76
900 AMA 450L8L 741 95.8 96.3 0.86 0.84 210 4.8 63 11597 0.7 1.8 51.5 4310 76
1000 AMA 450L8L 743 96.2 96.4 0.83 0.80 240 5.7 93 12854 0.9 2.2 56.7 4550 76
1120 AMA 500L8L 739 95.9 96.4 0.87 0.86 258 4.5 66 14463 0.7 1.8 75.5 5240 77
1250 AMA 500L8L 741 96.2 96.6 0.87 0.86 287 4.7 76 16105 0.7 1.8 84.9 5550 77
1400 AMA 500L8L 742 96.4 96.7 0.87 0.85 323 5.2 96 18015 0.8 2.0 93.7 5830 77
1600 AMA 500L8L 742 96.4 96.7 0.87 0.86 367 5.0 101 20601 0.8 1.9 102.6 6130 77

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

88 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


224 AMA 400L10L 591 93.6 93.8 0.75 0.70 61 4.2 30 3621 0.7 1.8 16.2 2660 75
250 AMA 400L10L 591 93.8 94.1 0.77 0.72 67 4.1 31 4042 0.7 1.8 17.6 2750 75
280 AMA 400L10L 591 93.9 94.2 0.77 0.73 74 4.1 33 4528 0.7 1.7 19.0 2850 75
315 AMA 400L10L 591 94.1 94.4 0.77 0.72 84 4.1 38 5092 0.7 1.8 20.5 2940 75
355 AMA 400L10L 592 94.3 94.4 0.76 0.71 96 4.5 46 5724 0.8 1.8 23.4 3120 75
400 AMA 400L10L 592 94.5 94.7 0.76 0.72 107 4.3 49 6454 0.8 1.7 24.8 3240 75
450 AMA 400L10L 592 94.7 94.8 0.75 0.70 121 4.6 59 7253 0.9 1.8 27.7 3420 75
500 AMA 450L10L 591 94.8 95.3 0.82 0.79 123 4.3 45 8073 0.7 1.7 40.5 3840 76
560 AMA 450L10L 592 95.0 95.4 0.82 0.79 138 4.4 52 9037 0.8 1.8 43.2 3960 76
630 AMA 450L10L 592 95.1 95.5 0.83 0.80 154 4.4 56 10167 0.8 1.8 48.6 4200 76
710
800
900
AMA 450L10L
AMA 500L10L
AMA 500L10L
592
594
593
95.2
95.8
95.9
95.6
96.0
96.2
0.83
0.82
0.84
0.81
0.78
0.81
172
196
215
4.4
5.1
4.8
60
79
75
11458
12857
14483
0.8
0.7
0.7
1.8
2.0
1.9
56.7
76.8
81.5
4560
5200
5390
76
77
77
3
1000 AMA 500L10L 594 96.0 96.2 0.84 0.81 238 5.0 83 16082 0.7 1.9 95.0 5810 77
1120 AMA 500L10L 594 96.1 96.3 0.83 0.79 270 5.2 104 17996 0.8 2.0 103.7 6100 77

500 r/min = 12 poles 3000 V 50 Hz


160 AMA 400L12L 491 92.4 92.5 0.73 0.68 45 3.7 23 3111 0.8 1.6 17.6 2740 75
180 AMA 400L12L 492 92.7 92.8 0.74 0.69 51 3.8 25 3496 0.7 1.7 19.2 2840 75
200 AMA 400L12L 492 92.9 93.0 0.74 0.69 56 3.8 27 3883 0.8 1.7 20.6 2940 75
224 AMA 400L12L 492 93.1 93.1 0.73 0.68 63 3.8 31 4347 0.8 1.7 22.1 3030 75
250 AMA 400L12L 493 93.3 93.1 0.72 0.67 71 4.0 37 4847 0.8 1.8 23.5 3130 75
280 AMA 400L12L 492 93.1 93.2 0.73 0.68 79 3.8 39 5434 0.8 1.7 24.9 3200 75
355 AMA 450L12L 494 94.5 94.6 0.74 0.68 98 4.3 51 6866 0.8 1.9 40.7 3820 76
400 AMA 450L12L 494 94.6 94.7 0.74 0.68 111 4.3 58 7736 0.8 1.9 43.4 3940 76
450 AMA 450L12L 494 94.7 94.8 0.75 0.70 122 4.2 60 8706 0.7 1.8 48.8 4180 76
500 AMA 450L12L 493 94.6 94.8 0.76 0.71 134 4.0 63 9680 0.7 1.7 51.5 4270 76
560 AMA 450L12L 493 94.7 94.9 0.75 0.70 151 4.2 72 10836 0.7 1.8 56.8 4520 76
630 AMA 500L12L 493 95.0 95.3 0.78 0.74 163 4.1 70 12197 0.6 1.7 76.4 5190 77
710 AMA 500L12L 493 95.2 95.4 0.78 0.74 183 4.2 79 13742 0.6 1.7 85.3 5500 77
800 AMA 500L12L 493 95.3 95.6 0.79 0.75 206 4.0 86 15492 0.6 1.7 89.7 5680 77
900 AMA 500L12L 494 95.4 95.6 0.78 0.74 231 4.2 99 17415 0.6 1.7 103.1 6100 77

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 89


HV Non-sparking modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


710 AMA 400L2L 2973 95.6 95.8 0.86 0.84 83 5.0 23 2280 0.6 2.1 6.1 2820 82
800 AMA 400L2L 2974 95.8 96.1 0.88 0.86 92 5.1 23 2569 0.6 2.1 6.5 2920 82
900 AMA 400L2L 2974 96.0 96.3 0.88 0.88 102 5.2 24 2890 0.6 2.1 7.0 3030 82
1000 AMA 400L2L 2977 96.2 96.5 0.89 0.87 113 5.4 27 3208 0.6 2.2 7.3 3140 82
1250 AMA 450L2L 2977 96.5 96.6 0.88 0.87 142 5.0 34 4010 0.5 2.1 12.1 4020 83
1400 AMA 450L2L 2978 96.6 96.8 0.86 0.85 162 5.0 42 4489 0.5 2.1 12.8 4170 83
1800 AMA 500L2L 2984 96.8 96.9 0.88 0.87 202 5.2 52 5761 0.4 2.2 19.8 5030 84
2000 AMA 500L2L 2984 97.0 97.1 0.89 0.87 224 5.3 56 6400 0.5 2.2 21.1 5230 84
2240 AMA 500L2L 2984 97.1 97.2 0.89 0.87 250 5.4 63 7168 0.5 2.2 22.4 5420 84
2500 AMA 500L2L 2984 97.2 97.3 0.89 0.88 277 5.4 63 8000 0.5 2.2 25.1 5790 84

3 1500 r/min = 4 poles


710 AMA 400L4L 1487 95.6 95.8
6000 V 50 Hz
0.86 0.84 83 5.4 27 4558 0.7 2.2 15.1 2900 79
800 AMA 400L4L 1486 95.7 96.0 0.87 0.85 92 5.1 28 5142 0.6 2.0 15.1 2910 79
900 AMA 400L4L 1486 95.8 96.2 0.87 0.85 103 5.1 30 5785 0.7 2.0 16.1 3010 79
1000 AMA 400L4L 1484 95.7 96.2 0.89 0.89 112 4.8 26 6435 0.6 1.9 17.2 3100 79
1250 AMA 450L4L 1487 95.9 96.2 0.86 0.84 145 5.0 43 8029 0.6 2.0 27.7 3810 80
1400 AMA 450L4L 1486 96.1 96.4 0.87 0.86 160 5.0 42 8996 0.7 1.9 29.4 3940 80
1600 AMA 450L4L 1486 96.3 96.6 0.89 0.88 180 5.1 43 10281 0.7 1.9 33.0 4210 80
1800 AMA 500L4L 1489 96.3 96.5 0.89 0.88 203 5.0 49 11540 0.6 1.8 50.5 5070 81
2000 AMA 500L4L 1490 96.4 96.6 0.89 0.88 225 5.1 53 12822 0.6 1.9 53.5 5230 81
2240 AMA 500L4L 1490 96.5 96.8 0.89 0.88 252 5.1 60 14359 0.7 1.9 56.4 5390 81
2500 AMA 500L4L 1490 96.7 97.0 0.89 0.88 281 5.3 68 16021 0.7 2.0 62.2 5710 81

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

90 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


HV Non-sparking modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


500 AMA 400L6L 986 94.9 95.4 0.84 0.82 60 4.3 19 4842 0.6 1.7 13.7 2830 77
560 AMA 400L6L 987 95.0 95.4 0.84 0.81 68 5.0 25 5416 0.8 2.0 16.7 2810 77
630 AMA 400L6L 987 95.1 95.5 0.85 0.82 75 4.9 25 6096 0.8 1.9 18.0 2910 77
710 AMA 400L6L 988 95.4 95.7 0.85 0.82 85 5.3 30 6861 0.9 2.1 20.4 3100 77
800 AMA 400L6L 988 95.5 95.8 0.84 0.81 96 5.4 35 7730 0.9 2.1 21.6 3190 77
900 AMA 450L6L 991 95.8 96.1 0.86 0.83 106 5.3 35 8674 0.7 2.1 35.5 3830 78
1000 AMA 450L6L 990 96.0 96.4 0.87 0.85 115 5.1 34 9643 0.7 1.9 37.8 3950 78
1120 AMA 450L6L 991 96.2 96.5 0.86 0.84 130 5.3 40 10796 0.7 2.0 40.0 4080 78
1250 AMA 450L6L 990 96.1 96.5 0.87 0.85 144 5.0 40 12059 0.7 1.9 42.3 4190 78
1400 AMA 450L6L 990 96.2 96.6 0.87 0.86 161 5.1 44 13502 0.7 2.0 46.8 4430 78
1600
1800
2000
AMA 500L6L
AMA 500L6L
AMA 500L6L
991
991
991
96.3
96.4
96.5
96.7
96.8
96.9
0.88
0.89
0.89
0.87
0.88
0.88
181
203
224
5.3
5.3
5.3
47
51
53
15418
17344
19272
0.8
0.8
0.8
2.0
2.0
2.0
65.5
72.8
80.1
5210
5500
5800
79
79
79
3
750 r/min = 8 poles 6000 V 50 Hz
315 AMA 400L8L 739 94.0 94.5 0.84 0.81 39 4.6 14 4070 0.8 1.8 17.6 2690 75
355 AMA 400L8L 739 94.0 94.5 0.84 0.81 43 4.6 16 4586 0.8 1.8 19.0 2790 75
400 AMA 400L8L 739 94.5 94.9 0.84 0.81 49 4.7 17 5166 0.8 1.8 20.4 2880 75
450 AMA 400L8L 739 94.5 95.0 0.84 0.82 54 4.6 19 5815 0.8 1.8 21.8 2980 75
500 AMA 400L8L 739 94.6 95.1 0.84 0.82 60 4.6 21 6461 0.8 1.8 23.3 3070 75
560 AMA 400L8L 739 94.8 95.2 0.84 0.81 68 4.7 24 7234 0.9 1.8 24.7 3160 75
630 AMA 450L8L 742 95.3 95.7 0.83 0.80 76 5.2 29 8109 0.8 2.1 38.0 3670 76
710 AMA 450L8L 742 95.4 95.8 0.83 0.80 86 5.3 33 9138 0.8 2.1 40.7 3800 76
800 AMA 450L8L 741 95.5 96.0 0.86 0.84 94 4.7 29 10311 0.7 1.8 46.1 4030 76
900 AMA 450L8L 741 95.7 96.1 0.86 0.84 105 4.8 32 11598 0.7 1.8 51.5 4270 76
1000 AMA 500L8L 739 95.5 96.1 0.87 0.86 116 4.5 32 12914 0.7 1.8 66.7 4870 77
1120 AMA 500L8L 739 95.6 96.2 0.87 0.86 129 4.5 33 14464 0.7 1.8 75.5 5170 77
1250 AMA 500L8L 741 95.9 96.4 0.87 0.86 144 4.7 38 16101 0.7 1.8 85.0 5440 77
1400 AMA 500L8L 742 96.2 96.5 0.87 0.85 161 5.2 48 18011 0.8 2.0 93.9 5750 77
1600 AMA 500L8L 742 96.2 96.6 0.87 0.86 184 5.0 51 20596 0.7 1.9 102.8 6040 77

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 91


HV Non-sparking modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


224 AMA 400L10L 591 93.2 93.3 0.72 0.66 32 3.7 17 3618 0.6 1.7 13.9 2800 75
250 AMA 400L10L 591 93.4 93.5 0.72 0.66 36 3.7 19 4037 0.6 1.8 14.8 2900 75
280 AMA 400L10L 592 93.4 93.6 0.74 0.68 39 4.1 20 4520 0.7 1.8 18.1 2890 75
315 AMA 400L10L 591 93.7 93.9 0.75 0.70 43 4.0 21 5086 0.6 1.8 20.6 3080 75
355 AMA 400L10L 592 93.8 94.0 0.76 0.71 48 4.4 23 5725 0.8 1.8 23.4 3070 75
400 AMA 400L10L 592 93.9 94.2 0.77 0.72 53 4.3 24 6455 0.8 1.7 24.8 3170 75
450 AMA 450L10L 591 94.2 94.8 0.83 0.80 56 4.2 20 7268 0.7 1.7 37.9 3650 76
500 AMA 450L10L 591 94.4 94.9 0.83 0.80 62 4.3 22 8074 0.7 1.7 40.5 3770 76
560 AMA 450L10L 592 94.6 95.0 0.82 0.79 69 4.4 26 9038 0.8 1.8 43.2 3890 76
630 AMA 450L10L 592 94.7 95.2 0.83 0.80 77 4.4 28 10167 0.8 1.8 48.6 4120 76

3 710
800
900
AMA 500L10L
AMA 500L10L
AMA 500L10L
594
594
593
95.4
95.5
95.6
95.7
95.8
96.0
0.83
0.84
0.84
0.79
0.81
0.81
86
96
108
5.0
4.9
4.7
33
35
37
11414
12869
14484
0.7
0.7
0.7
2.0
1.9
1.9
72.4
77.0
81.5
4980
5130
5320
77
77
77
1000 AMA 500L10L 594 95.8 96.1 0.84 0.81 119 4.9 41 16082 0.7 1.9 95.0 5760 77
1120 AMA 500L10L 594 95.7 96.1 0.85 0.82 133 4.8 44 18019 0.7 1.8 104.0 6020 77

500 r/min = 12 poles 6000 V 50 Hz


160 AMA 400L12L 493 91.8 91.5 0.69 0.63 24 3.8 14 3101 0.7 1.8 18.1 2880 75
180 AMA 400L12L 493 91.9 91.6 0.69 0.63 27 3.7 16 3490 0.7 1.7 18.1 2880 75
200 AMA 400L12L 493 92.1 91.7 0.68 0.61 31 3.8 18 3875 0.8 1.8 19.4 2980 75
224 AMA 400L12L 492 92.2 92.0 0.70 0.63 34 3.7 19 4344 0.7 1.7 20.6 3070 75
250 AMA 400L12L 492 92.3 92.3 0.73 0.67 36 3.9 19 4848 0.8 1.8 23.5 3060 75
280 AMA 400L12L 492 92.4 92.5 0.74 0.69 40 3.7 20 5435 0.7 1.6 24.9 3150 75
315 AMA 450L12L 494 93.9 93.9 0.74 0.68 44 4.4 23 6091 0.8 1.9 38.0 3640 76
355 AMA 450L12L 494 94.0 94.1 0.75 0.69 49 4.4 25 6866 0.8 1.9 40.7 3760 76
400 AMA 450L12L 494 94.1 94.2 0.74 0.68 55 4.4 29 7736 0.8 1.9 43.4 3880 76
450 AMA 450L12L 494 94.3 94.4 0.76 0.70 61 4.3 30 8706 0.8 1.8 48.8 4120 76
500 AMA 450L12L 493 93.9 94.3 0.77 0.72 67 4.1 31 9681 0.7 1.7 51.5 4200 76
560 AMA 500L12L 494 94.6 94.8 0.78 0.73 73 4.4 34 10831 0.7 1.9 71.8 4960 77
630 AMA 500L12L 493 94.6 95.0 0.79 0.75 81 4.2 35 12197 0.7 1.8 76.4 5110 77
710 AMA 500L12L 493 94.8 95.1 0.79 0.75 91 4.3 39 13741 0.7 1.8 85.3 5410 77
800 AMA 500L12L 493 95.0 95.3 0.79 0.75 102 4.2 43 15491 0.6 1.7 89.7 5600 77
900 AMA 500L12L 494 95.2 95.4 0.79 0.75 115 4.4 49 17414 0.7 1.8 103.1 6040 77

Data presented in rating lists are typical values. Guaranteed values


on request. All engineered motors are optimized for the specied
application. Accurate motor data will be given on request at quotation
phase. Legally binding performance and specication data is given to
the end user once each order is conrmed.

92 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, HXR
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

355L 2 610 630 254 70 140 20 355 980 1195 1505 35 1080 380
355L 4 610 630 254 100 210 28 355 980 1195 1670 35 1150 450
400L 2 710 900 224 80 170 22 400 1030 1285 1765 35 1325 430
400L 4 710 900 224 110 210 28 400 1030 1285 1900 35 1365 470
450L 2 800 1000 250 80 170 22 450 1075 1385 1985 42 1520 445
450L 4 800 1000 250 110 210 28 450 1075 1385 2120 42 1560 485
500L 2 900 1250 280 90 170 25 500 1175 1510 2320 42 1800 460
500L 4 900 1250 280 120 210 32 500 1175 1510 2455 42 1840 500
560L 4 1000 1600 400 160 300 40 560 1285 1655 3025 48 2350 630

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

355L 2 120 700 745 210 886 55 6317M/C3 6317M/C3


355L 4 120 700 745 210 886 55 6322/C3 6319/C3
400L 2 140 840 840 260 1120 35 6317M/C3 6317M/C3
400L 4 140 840 840 260 1120 35 6324/C3 6319/C3
450L 2 160 950 940 320 1300 40 6317M/C3 6317M/C3
450L 4 160 950 940 320 1300 40 6324/C3 6322/C3
500L 2 170 1050 1050 375 1570 45 6319M/C3 6319M/C3
500L 4 170 1050 1050 375 1570 45 6326/C3 6324/C3
560L 4 230 1170 1190 620 1940 50 6034/C3 + NU1034/C3 NU322/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 93


Non-sparking engineered motors, HXR
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

450L 2 800 1000 250 80 170 22 450 1225 1505 1985 42 1520 445
450L 4 800 1000 250 110 210 28 450 1225 1505 2120 42 1560 485
500L 2 900 1250 280 90 170 25 500 1280 1630 2320 42 1800 460
500L 4 900 1250 280 120 210 32 500 1280 1630 2455 42 1840 500
560L 4 1000 1600 400 160 300 40 560 1360 1780 3025 48 2350 630

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

450L 2 160 950 940 320 1300 40 6317/C3 6317/C3


450L 4 160 950 940 320 1300 40 6324/C3 6322/C3
500L 2 170 1050 1050 375 1570 45 6319M/C3 6319M/C3
500L 4 170 1050 1050 375 1570 45 6326/C3 6324/C3
560L 4 230 1170 1190 620 1940 50 6034/C3 + NU1034/C3 NU322/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

94 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, HXR
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM3011, IC411

HXR Poles M N P S D E F G GD HD L LA

355L 2 740 680 800 23 70 140 20 62.5 12 1225 1505 25


355L 4 740 680 800 23 100 210 28 90 16 1225 1670 25
400L 2 940 880 1000 28 80 170 22 71 14 1370 1765 30
400L 4 940 880 1000 28 110 210 28 100 16 1370 1900 30
450L 4 1080 1000 1150 28 110 210 28 100 16 1495 2120 30
500L 4 1080 1000 1150 28 120 210 32 109 18 1570 2455 30
560L 6 1320 1250 1400 28 160 300 40 147 22 1780 3005 40

HXR Poles LD LE LF T AC AD AE D-end bearing N-end bearing

355L 2 395 1080 130 6 750 822 745 6317M/C3 7317 BM


355L 4 465 1150 130 6 750 822 745 6322/C3 7319 BM
400L 2 425 1315 150 6 840 867 790 6317M/C3 7317 BM
400L 4 465 1355 150 6 840 867 790 6324/C3 7319 BM
450L 4 480 1555 180 6 940 917 840 6324/C3 7322 BM
500L 4 510 1850 200 6 1040 992 915 6326/C3 7324 BM
560L 6 630 2350 250 6 1190 1077 1000 6034/C3 7334 BM
Note! Rain canopy is recommended for outdoor location.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 95


Non-sparking engineered motors, HXR
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 3011, IC411

HXR Poles M N P S D E F G GD HD L LA

450L 4 1080 1000 1150 28 110 210 28 100 16 1590 2120 30


500L 4 1080 1000 1150 28 120 210 32 109 18 1665 2455 30
560L 6 1320 1250 1400 28 160 300 40 147 22 1875 3005 40

HXR Poles LD LE LF T AC AD AE D-end bearing N-end bearing

450L 4 480 1555 180 6 940 1012 935 6324/C3 7322 BM


500L 4 510 1850 200 6 1040 1087 1010 6326/C3 7324 BM
560L 6 630 2350 250 6 1190 1172 1095 6034/C3 7334 BM
Note! Rain canopy is recommended for outdoor location.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

96 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, HXR
Dimension drawings
Sleeve bearings, 1 < UN 6.6 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

355L 2 610 630 475 70 140 20 355 980 1195 1905 35 1300 600
355L 4 610 630 475 100 210 28 355 980 1195 2075 35 1370 670
400L 2 710 900 450 80 170 22 400 1030 1285 2170 35 1550 655
400L 4 710 900 450 110 210 28 400 1030 1285 2305 35 1590 695
450L 2 800 1000 475 80 170 22 450 1075 1385 2390 42 1745 670
450L 4 800 1000 475 110 210 28 450 1075 1385 2525 42 1785 710
500L 2 900 1250 500 90 170 25 500 1175 1510 2705 42 2020 680
500L 4 900 1250 500 120 210 32 500 1175 1510 2840 42 2060 720
560L 2 1000 1600 670 120 210 32 560 1285 1655 3280 48 2530 810
560L 4 1000 1600 670 160 300 40 560 1285 1655 3465 48 2620 900

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

355L 2 120 700 750 210 886 55 EFZLB 9-80 1) EFZLQ 9-80 1)
355L 4 120 700 750 210 886 55 EFZLB 9-90 EFZLQ 9-90
400L 2 140 840 840 260 1120 35 EFZLB 9-80 1) EFZLQ 9-80 1)
400L 4 140 840 840 260 1120 35 EFZLB 9-100 EFZLQ 9-100
450L 2 160 950 940 320 1300 40 EFZLB 9-80 1) EFZLQ 9-80 1)
450L 4 160 950 940 320 1300 40 EFZLB 9-100 2) EFZLQ 9-100 2)
500L 2 170 1050 1050 375 1570 45 EFZLB 9-90 1) EFZLQ 9-90 1)
500L 4 170 1050 1050 375 1570 45 EFZLB 11-100 2) EFZLQ 9-100 2)
560L 2 230 1170 1190 620 1940 50 EFZLB 14-125 1) EFZLQ 14-125 1)
560L 4, 6 230 1170 1190 620 1940 50 EFZLB 14-125 2) EFZLQ 14-125 2)
560L 8 230 1170 1190 620 1940 50 EFZLB 14-140 EFZLQ 14-140
1)
With oil circulation as standard. The above table gives the main dimensions in mm.
2)
With oil circulation as standard for 4 poles.
The customer is responsible for the preparation of the
Note! Axial oat of rotor as standard 8 mm.
foundation. Certied outline drawing is delivered with each
Note! The bearing cannot withstand continuous axial forces.
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 97


Non-sparking engineered motors, HXR
Dimension drawings
Sleeve bearings, 6.6 < UN 11 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

450L 2 800 1000 475 80 170 22 450 1225 1505 2390 42 1745 670
450L 4 800 1000 475 110 210 28 450 1225 1505 2525 42 1785 710
500L 2 900 1250 500 90 170 25 500 1280 1630 2705 42 2020 680
500L 4 900 1250 500 120 210 32 500 1280 1630 2840 42 2060 720
560L 2 1000 1600 670 120 210 32 560 1360 1780 3280 48 2530 810
560L 4 1000 1600 670 160 300 40 560 1360 1780 3465 48 2620 900

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

450L 2 160 950 940 320 1300 40 EFZLB 9-80 1) EFZLQ 9-80 1)
450L 4 160 950 940 320 1300 40 EFZLB 9-100 2) EFZLQ 9-100 2)
500L 2 170 1050 1050 375 1570 45 EFZLB 9-90 1) EFZLQ 9-90 1)
500L 4 170 1050 1050 375 1570 45 EFZLB 11-100 2) EFZLQ 9-100 2)
560L 2 230 1170 1190 620 1940 50 EFZLB 14-125 1) EFZLQ 14-125 1)
560L 4, 6 230 1170 1190 620 1940 50 EFZLB 14-125 2) EFZLQ 14-125 2)
560L 4 230 1170 1190 620 1940 50 EFZLB 14-140 EFZLQ 14-140
1)
With oil circulation as standard.
2)
With oil circulation as standard for 4 poles.
Note! Axial oat of rotor as standard 8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

98 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

400L 2 750 1250 200 85 170 22 76 400 35 2290 150 880 855 335
400L 4 750 1250 200 110 210 28 100 400 35 2330 150 880 855 335
450L 2 850 1400 200 90 170 25 81 450 42 2480 150 980 905 335
450L 4 850 1400 200 125 210 32 114 450 42 2520 150 980 905 335
500L 4 950 1600 200 140 250 36 128 500 42 2830 150 1080 955 335

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1400 545 1450 445 14 20 130 1590 615 1480 565 6319M/C3 6319M/C3
400L 4 1400 545 1450 445 16 20 130 1590 655 1520 565 6324/C3 6319/C3
450L 2 1500 575 1600 465 14 25 230 1760 710 1630 665 6319M/C3 6319M/C3
450L 4 1500 575 1600 465 18 25 230 1760 750 1670 665 6326/C3 6322/C3
500L 4 1605 645 1800 495 20 35 330 1960 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 99


Non-sparking engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 4011, IC611 / IP55

AMA Poles M N P S D E F G HD L LA LD LE

400L 4 1080 1000js6 1130 28 110 210 28 100 1755 2330 30 655 1150
450L 4 1180 1120h8 1230 28 125 210 32 114 1925 2520 40 750 1300
500L 4 1320 1250h8 1370 28 140 250 36 128 2145 2830 47 860 1540

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L 4 6 855 775 1425 16 50 6324/C3 7319B


450L 4 7 905 825 1525 18 50 6326/C3 7322B
500L 4 8 955 875 1645 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

100 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, AMA
Dimension drawings
Sleeve bearings, 1 < UN 6.6 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

400L 2 750 1250 375 85 170 22 76 400 35 2465 150 880 855 335 1400 545
400L 4 750 1250 375 110 210 28 100 400 35 2505 150 880 855 335 1400 545
450L 2 850 1400 375 90 170 25 81 450 42 2655 150 980 905 335 1500 575
450L 4 850 1400 400 125 210 32 114 450 42 2720 150 980 905 335 1500 575
500L 2 950 1600 375 110 210 28 100 500 42 2965 150 1080 955 335 1605 645
500L 4 950 1600 450 140 250 36 128 500 42 3080 150 1080 955 335 1605 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1450 445 14 20 130 1590 790 1655 565 EFZLB9-80 EFZLQ9-80
400L 4 1450 445 16 20 130 1590 830 1695 565 EFZLB9-100 EFZLQ 9-100
450L 2 1600 465 14 25 230 1760 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L 4 1600 465 18 25 230 1760 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 330 1960 995 2045 765 EFZLB9-100 1) EFZLQ9-100 1)
500L 4 1800 495 20 35 330 1960 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L 6 1800 495 20 35 330 1960 1110 2160 765 EFZLB14-140 EFZLQ11-125
1)
With oil circulation as standard.
Note! Axial oat of rotor as standard 8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 101


Non-sparking engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

450L 2 850 1400 200 90 170 25 81 450 42 2480 150 980 1005 430
450L 4 850 1400 200 125 210 32 114 450 42 2520 150 980 1005 430
500L 4 950 1600 200 140 250 36 128 500 42 2830 150 1080 1055 430

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 575 1600 465 14 25 35 1760 710 1630 665 6319M/C3 6319M/C3
450L 4 1600 575 1600 465 18 25 35 1760 750 1670 665 6326/C3 6322/C3
500L 4 1700 645 1800 495 20 35 135 1960 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

102 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 4011, IC611 / IP55

AMA Poles M N P S D E F G HD L LA LD LE

450L 4 1180 1120h8 1230 28 125 210 32 114 1925 2520 40 750 1100
500L 4 1320 1250h8 1370 28 140 250 36 128 2145 2830 47 860 1340

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

450L 4 7 1000 920 1620 18 50 6326/C3 7322B


500L 4 8 1050 970 1740 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 103


Non-sparking engineered motors, AMA
Dimension drawings
Sleeve bearings, 6.6 < UN 11 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

450L 2 850 1400 375 90 170 25 81 450 42 2655 150 980 1005 430 1600 575
450L 4 850 1400 400 125 210 32 114 450 42 2720 150 980 1005 430 1600 575
500L 2 950 1600 375 110 210 28 100 500 42 2965 150 1080 1055 430 1700 645
500L 4 950 1600 450 140 250 36 128 500 42 3080 150 1080 1055 430 1700 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 465 14 25 35 1760 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L 4 1600 465 18 25 35 1760 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 135 1960 995 2045 765 EFZLB9-100 1) EFZLQ9-100 1)
500L 4 1800 495 20 35 135 1960 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L 6 1800 495 20 35 135 1960 1110 2160 765 EFZLB14-140 EFZLQ11-125
1)
With oil circulation as standard.
Note! Axial oat of rotor as standard 8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

104 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

400L 2 750 1250 200 85 170 22 76 400 35 1825 150 880 855 335
400L 4 750 1250 200 110 210 28 100 400 35 1865 150 880 855 335
450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 905 335
450L 4 850 1400 200 125 210 32 114 450 42 2025 150 980 905 335
500L 4 950 1600 200 140 250 36 128 500 42 2265 150 1080 955 335

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1400 545 1450 445 14 20 130 1670 615 1480 565 6319M/C3 6319M/C3
400L 4 1400 545 1450 445 16 20 130 1670 655 1520 565 6324/C3 6319/C3
450L 2 1500 575 1600 465 14 25 230 1870 710 1630 665 6319M/C3 6319M/C3
450L 4 1500 575 1600 465 18 25 230 1870 750 1670 665 6326/C3 6322/C3
500L 4 1605 645 1800 495 20 35 330 2070 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 105


Non-sparking engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 4011, IC81W / IP55

AMA Poles M N P S D E F G HD L LA LD LE

400L 4 1080 1000js6 1130 28 110 210 28 100 1835 1860 30 655 1150
450L 4 1180 1120h8 1230 28 125 210 32 114 2035 2020 40 750 1300
500L 4 1320 1250h8 1370 28 140 250 36 128 2255 2260 47 860 1540

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L 4 6 855 775 1425 16 50 6324/C3 7319B


450L 4 7 905 825 1525 18 50 6326/C3 7322B
500L 4 8 955 875 1645 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

106 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, AMA
Dimension drawings
Sleeve bearings, 1 < UN 6.6 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

400L 2 750 1250 375 85 170 22 76 400 35 2065 150 880 855 335 1400 545
400L 4 750 1250 375 110 210 28 100 400 35 2100 150 880 855 335 1400 545
450L 2 850 1400 375 90 170 25 81 450 42 2215 150 980 905 335 1500 575
450L 4 850 1400 400 125 210 32 114 450 42 2275 150 980 905 335 1500 575
500L 2 950 1600 375 110 210 28 100 500 42 2485 150 1080 955 335 1605 645
500L 4 950 1600 450 140 250 36 128 500 42 2595 150 1080 955 335 1605 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1450 445 14 20 130 1670 790 1655 565 EFZLB9-80 EFZLQ9-80
400L 4 1450 445 16 20 130 1670 830 1695 565 EFZLB9-100 EFZLQ 9-100
450L 2 1600 465 14 25 230 1870 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L 4 1600 465 18 25 230 1870 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 330 2070 995 2045 765 EFNLB11-90 EFNLB11-90
500L 4 1800 495 20 35 330 2070 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L 6 1800 495 20 35 330 2070 1110 2160 765 EFZLB14-140 EFZLQ11-125
Note! Axial oat of rotor as standard 8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 107


Non-sparking engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 1001, IC81W / IP55
J

AMA Poles A B C D E F G H K L AA AB AC AD

450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 1005 430
450L 4 850 1400 200 125 210 32 114 450 42 2025 150 980 1005 430
500L 4 950 1600 200 140 250 36 128 500 42 2265 150 1080 1055 430

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 575 1600 465 14 25 35 1870 710 1630 665 6319M/C3 6319M/C3
450L 4 1600 575 1600 465 18 25 35 1870 750 1670 665 6326/C3 6322/C3
500L 4 1700 645 1800 495 20 35 135 2070 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

108 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Non-sparking engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 4011, IC81W / IP55

AMA Poles M N P S D E F G HD L LA LD LE

450L 4 1180 1120h8 1230 28 125 210 32 114 2035 2030 40 750 1100
500L 4 1320 1250h8 1370 28 140 250 36 128 2255 2270 47 860 1340

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

450L 4 7 1000 920 1620 18 50 6326/C3 7322B


500L 4 8 1050 970 1740 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008 109


Non-sparking engineered motors, AMA
Dimension drawings
Sleeve bearings, 6.6 < UN 11 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

450L 2 850 1400 375 90 170 25 81 450 42 2215 150 980 1005 430 1600 575
450L 4 850 1400 400 125 210 32 114 450 42 2275 150 980 1005 430 1600 575
500L 2 950 1600 375 110 210 28 100 500 42 2485 150 1080 1055 430 1700 645
500L 4 950 1600 450 140 250 36 128 500 42 2595 150 1080 1055 430 1700 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 465 14 25 35 1870 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L 4 1600 465 18 25 35 1870 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 135 2070 995 2045 765 EFNLB11-90 EFNLB11-90
500L 4 1800 495 20 35 135 2070 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L 6 1800 495 20 35 135 2070 1110 2160 765 EFZLB14-140 EFZLQ11-125

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

110 ABB/ BU Machines / HV Motors for COG / Non-sparking EN 02-2008


Increased safety engineered motors
Squirrel cage three phase high voltage motors,

For Zone 1 and 2

www.abb.com/motors&generators
> Motors
>> Motors and Generators for Hazardous Areas

ABB/ BU Machines / Motors for COG / Increased safety EN 02-2008 111


ABB has a full range of increased safety motors
available. The motors are optimized for the specied
application and manufactured on a case-by-case basis.
Please contact ABB for further details.

112 ABB/ BU Machines / Motors for COG / Increased safety EN 02-2008


Pressurized engineered motors
Squirrel cage three phase high voltage motors,
Up to 2800 kW
For Zone 1 and 2

www.abb.com/motors&generators
> Motors
>> Motors and Generators for Hazardous Areas

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 113


Contents Page
General Information 115
Enclosure and Cooling 116
Type designation 118
High voltage terminal box for pressurized motors 119
Auxiliary boxes 123
Bearings 124
Vibrations 129
Notes 130
Technical Data 131
Technical Data, Pressurized cast iron motors, HXR 131
Technical Data, Pressurized modular motors 143
Dimension Drawings, Pressurized engineered motors, HXR, IC411 159
Dimension Drawings, Pressurized engineered motors, AMA, IC611 165
Dimension Drawings, Pressurized engineered motors, AMA, IC81W 171

ABB reserves the right to change the design,


technical specication and dimensions
without prior notice.

114 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


General Information
ABB's engineered motors are tailor-made to meet its The AMA range features a welded steel frame and is
customers' needs. All ABB engineered motors are available as standard with the following cooling methods
congured and optimized individually for each order and and protection types: IC 611 / IP 55 and IC 81W / IP 55.
application. Please contact ABB for further information. The standard shaft heights are between 400 and
500 mm.
This catalogue contains information on ABBs standard
construction squirrel-cage induction motors operating at The HXR range features a rugged cast iron frame and
50 Hz and with synchronous speed from 500 to is totally enclosed fan cooled motor of IC 411 / IP 55.
3000 rpm. The output range is up to 2800 kW. HXR motors have standard shaft heights between 355
and 560 mm.
This catalogue describes two different motor types,
the AMA range and the HXR range. Both motor types The table below shows the available output power,
can be operated with variable speed drives or used voltage range and pole numbers for the motor types
as induction generators and motors can be mounted described in this catalogue.
horizontally or vertically. Either motor can be used for
both standard and special applications.

Output (kW) at 50 Hz Output (kW) at 50 Hz


HXR AMA
Poles 3 kV 6 kV 10 kV 3 kV 6 kV 10 kV
2 100 - 1730 160 - 1600 400 - 1250 630 - 2500 630 - 2500 560 - 1800
4 100 - 2240 160 - 2000 355 - 1400 630 - 2800 630 - 2800 630 - 2240
6 160 - 2000 125 - 1800 315 - 1400 450 - 2250 450 - 2250 450 - 1600
8 200 - 1800 180 - 1600 315 - 1120 280 - 1600 280 - 1600 630 - 1250
10 160 - 1400 224 - 1250 560 - 710 200 - 1120 200 - 1120 450 - 800
12 140 - 1120 140 - 1000 - 140 - 900 140 - 900 315 - 630
Output ranges of ABB motors (Temperature rise class B, insulation class F). Other voltages on request.

Higher voltage, speed and power ratings are available


5
on request. Please contact ABB for further information.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 115


Enclosure and Cooling
Standard combinations used for AMA-motors are:

IC 611 / IP 55
In this design the fully enclosed motor has an air-
to-air heat exchanger mounted on the motor. Shaft
mounted fans are tted both inside and outside of the
casing to supply the inside and outside cooling circuits
respectively. The motor is protected against dust and
splashing water from any direction.

IC 81W / IP 55
This fully enclosed motor is tted with an air-to-water
heat exchanger. A shaft mounted fan is tted inside the
casing to supply the internal cooling circuit. Motor is
protected against dust and splashing water from any
direction.

5
The terminal boxes have a protection of at least IP 55.

116 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


IC 411 / IP55 HXR motor
The HXR motor has an external shaft mounted fan protected against dust and water jets. The principle of
that use the surrounding air for cooling. The motor is this motor is shown in below:

Sectional drawing of IC 411 / IP55 motor.

Protection denition IP55 Method of Cooling (IC 411)


In a dust-protected motor, some dust can ingress the Frame surface cooled:
motor but it does not enter in sufcient quantity to The primary coolant is circulated in a closed circuit
interfere with the motor's operation. in the motor and gives its heat through the external
surface of the motor (in addition to the heat transfer
The motor protected against water jets:
via the stator core and other heat conducting parts) to
Water projected by a nozzle against the motor from any
the nal coolant which is the surrounding medium. The
direction shall have no harmful effect.
surface may be plain or ribbed, with or without an outer
shell to improve the heat transfer.
Self circulation:
The coolant is moved dependent on the rotational 5
speed of the main motor either by action of the rotor
alone or by means of a component designed for this
purpose and mounted directly on the rotor of the main
motor, or by a fan or pump unit mechanically driven by
the rotor or the main motor.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 117


Type designation
The type designation of the AMA motor follows
the coding principle shown below.

Example: AMA 450L4A BATH


1 AM Stands for Alternating Current Machines
2 A Indicates the type of machine, A - E = SCIM, K - P = WRIM
3 450 Frame size in mm, 400, 450 or 500
4 L Frame length, S = small, M = medium or L = long
5 4 Number of poles
6 A Stands for the IC/IP combination
D = IC01 / IP23 [WP I] L = IC81W / IP54 (55) [TEWAC]
W = IC01 / IPW24 [WP II] A = IC611 / IP55 [TEAAC]
P = IC11, 21, 31 / IP23, 54 (55) [OPV, TEPV]
7 B Mounting arrangement, B = IM1001 (Horizontal), V = IM4011 (Vertical)
8 A Bearing type, A = antifriction, S = sleeve
9 T Indication of special construction
T = separate ventilation X = electrically special
N = Non-sparking design F = frequency converter drive Y = mechanically special
10 H Location of manufacture

The type designation of the HXR motor follows


the coding principle shown below.

Example: HXR 355LA4


1. HXR Stands for the HXR machine family, three digits.
2. 355 Shaft height in mm, three digits.
3. L Frame length, one digit.
4. A Core length, one digit.
5. 4 Number of poles.

118 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


High voltage terminal box for pressurized motors
The picture shows the high voltage terminal box with its
main technical data below.

Technical data:
Voltage (max.) 6.6 kV Materials:
Current (max.) 400 A Box welded sheet steel (thickness
Dynamic short circuit current 75 kA (0.25 s) min. 3 mm)
No of cables (max.) 1 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators epoxy casting resin or
Clearance (min.) 60 mm polyurethane resin
Creepage (min.) 119 mm Grounding pad stainless steel
Gross volume 47.3 dm3
Usable volume 42.1 dm3 Other features:
Connection screws M16 (3 pcs) - rigid welded construction
Connection nuts tightening torque 40 Nm - ample size for making connections of supply cables
Ground connections M12 (both in- and out - box turnable to allow cable entry from left or right side
side) - box turnable in steps of 90
Weight 33 kg - either 3-phase or 1-phase cables can be connected
Protection IP66 - pressure relief plate in the bottom of the box in case
Standard DIN 42962 TEIL 1, A2 of an arching short circuit
- different cable glands available
- terminal box tested acc. to IEC 298 concerning
internal arc strength

Figure above: High voltage terminal box. Dimensions in mm.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 119


High voltage terminal box for pressurized motors
Figure below shows the high voltage terminal box with
its main technical data.

Technical data: Materials:


Voltage (max.) 6.6 kV Box welded sheet steel (thickness
Current (max.) 800 A min. 3 mm)
No of cables (max.) 2 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators polyurethane resin or epoxy
Clearance (min.) 70 mm casting resin
Creepage (min.) 119 mm Grounding pad stainless steel
Gross volume 194.6 dm3
Usable volume 186.5 dm3 Other features:
Connection screws (M16x1/M12x2/ - rigid welded construction
M10x2)/phase - ample size for making connections of supply cables
Tightening torque for - box turnable to allow cable entry from left or right side
connection nuts 40 Nm - box turnable in steps of 90
Ground connections M12 (both in- and - either 3-phase or 1-phase cables can be connected
outside) - pressure relief plate in the bottom of the box in case
Weight 90 kg of an arching short circuit
Protection IP66 - different cable glands available
Standards DIN 42962 Teil 2, D2
(internal dimensions)

Figure above: High voltage terminal box. Dimensions in mm.

120 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


High voltage terminal box for pressurized motors
The picture shows high voltage terminal box with its
main technical data below.

Technical data: Materials:


Voltage (max.) 11.0 kV Box welded sheet steel (thickness
Current (max.) 400 A min. 3 mm)
No of cables (max.) 1 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators epoxy casting resin
Clearance (min.) 100 mm Grounding pad stainless steel
Creepage (min.) 158 mm
Gross volume 122 dm3 Other features:
Usable volume 116 dm3 - rigid welded construction
Connection screws M16 (3 pcs) - ample size for making connections of supply cables
Connection nuts tightening torque 40 Nm - box turnable to allow cable entry from left or right side
Ground connections M12 (both in- and - box turnable in steps of 90
outside) - either 3-phase or 1-phase cables can be connected
Weight 62 kg - pressure relief plate in the bottom of the box in case
Protection IP66 of an arching short circuit
Standard DIN 42962 TEIL 2, C2 - different cable glands available

Figure above: High voltage terminal box. Dimensions in mm.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 121


Dimensions for terminal box inlet, blind ange
As standard, main terminal boxes are with blind ange.
Cable glands are available on request.

Figure above: Blind ange FL 33 for main terminal box.

122 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Auxiliary boxes
As standard motors in safe area are equipped with one As standard motors in hazardous area are equipped
common auxiliary terminal box for monitoring devices with two auxiliary terminal boxes, one for monitoring
and space heaters. devices and one for space heaters.

Type designation Use Size (W x L x H)


mm
ZWA ALX122208 Standard 125 x 222 x 81

ZWA ALX233318 Is used when additional space is needed 230 x 330 x 180

Table above: Standard auxiliary terminal boxes.

The typical arrangements for standard terminal boxes the motor. Additional terminals can be supplied on
are shown below. The number of terminal blocks request.
depends on the number of accessories equipped with

Standard terminal box ZWA ALX122208


with terminal blocks and cable glands.
1) Cable gland M20x1.5 for cable outer
diameter 10...14 mm (2 pcs)
2) Threaded hole for cable gland M16x1.5
(3 pcs), plugged.

Standard terminal box ZWA ALX233318


with terminal blocks and cable glands.
1) Cable gland M20x1.5 for cable outer
diameter 10...14 mm (4 pcs)
2) Threaded hole for cable gland M16x1.5
(3 pcs), plugged.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 123


Bearings
Horizontal motors
Horizontal motors 355 - 500 have deep groove ball stated in table below and the bearing construction is
bearings in both ends. HXR 560 has a double bearing shown in the gures on page 125.
arrangement (deep groove ball bearing and a cylindrical
The standard bearing solution is designed to carry the
roller bearing) at D-end and cylindrical roller bearing at
weight of the typical coupling half and the weight of
N-end (only horizontal motor available).
the motor rotor only. Any additional radial or axial force
The bearing in D-end is axially locked in horizontal caused by driven equipment may need the bearings to
motors. Standard bearings of horizontal motors are be specially constructed.

Table below: Standard bearings for horizontal motors.

Frame size Poles D-end N-end

HXR 355 2 6317M/C3 6317M/C3


HXR 355 4 6322/C3 6319/C3
HXR 400 2 6317M/C3 6317M/C3
HXR 400 4 6324/C3 6319/C3
HXR 450 2 6317M/C3 6317M/C3
HXR 450 4 6324/C3 6322/C3
HXR 500 2 6319M/C3 6319M/C3
HXR 500 4 6326/C3 6324/C3
HXR 560 4 6034/C3 + NU1034/C3 NU322/C3
HXR 560 2 sleeve* sleeve*

5 AMA 400 2 6319M/C3 6319M/C3


AMA 400 4 6324/C3 6319/C3
AMA 450 2 6319M/C3 6319M/C3
AMA 450 4 6326/C3 6322/C3
AMA 500 4 6330/C3 6324/C3
AMA 500 2 sleeve* sleeve*
* See section sleeve bearings.

124 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Figure below: Standard bearing construction for horizontally mounted motors, frame sizes 355-500.

1 Groove ball bearing


2 Inner bearing cover
3 Grease valve
4 Outer bearing cover
5 Circlip
6 Hexagon screw
7 Spring
8 O-ring

D-end, axially locked N-end, axially free

Figure below: Standard bearing construction for horizontally mounted motors HXR 560.

1 Inner bearing cover 1 Cylindrical roller bearing


2 Cylindrical roller bearing 2 Inner bearing cover
3 Grease valve 3 Grease valve
4 Outer bearing cover 4 Outer bearing cover
5 Deep groove ball bearing 5 Circlip
6 Outer bearing cover lid 6 Hexagon screw
7 Labyrinth seal
8 Grub screw

D-end, axially locked N-end, axially free

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 125


Bearing rating life
Most motors with standard bearings have a rated life The basic rated life L10h is the number of hours at rated
time L10h in excess of 100000 h. Rated life time for frame bearing load and speed that 90% of a group of identical
500, 2-pole, may be less than 100000h. The life times bearings will complete or exceed before the rst
are calculated in accordance with ISO R 281-1. evidence of failure.

Lubrication intervals
The motors are equipped with greasing nipple(s) in grease and the interval of greasing are stamped on the
both ends for lubricating the bearings. The greasing relubrication plate. The values are also shown in the
nipples are located on top of the motor. The amount of table below.

Table below: Relubrication intervals and grease amount.

Bearing Amount of Lubrication intervals in running hours at different speeds [rpm]


type grease [g] 3600 3000 1800 - 1500 1200 - 1000 900 - 750 600 - 500

6317 35 800 2200 8800 8800 8800 8800


6319 45 400 1600 6600 8800 8800 8800
6322 60 6600 8800 8800 8800
6324 70 4400 8800 8800 8800
6326 80 4400 8800 8800 8800
6034 55 1600 3300 6600 8800
NU1034 55 1600 3300 4400 8800
NU322 60 3300 4400 4400 8800
7317 35 1100 4400 4400 4400 6600

5 7319
7322
45
60
800 3300
3300
4400
4400
4400
4400
6600
6600
7324 70 2200 4400 4400 6600
NB: Ball bearings on vertical motors should be lubricated twice as frequently as horizontal motors. The motor type is indicated by the rst letter
of the bearing type (6).

126 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Sleeve bearings
The axial oat of rotor is as standard 8 mm from Sleeve bearings are generally self-cooled, oil ring
mechanical center. The running center locates within lubricated but some require external ood lubrication.
the oat area and therefore operation is also allowed Please see the lubrication table below for standard
while machine is uncoupled, e.g. during test run. A lubrication requirements based on a maximum 40 C
pointer showing running center with regard to end limits ambient and 50 Hz operation. Consult ABB for ambient
is available as standard. Continuous axial forces are temperatures above 40 C, and/or for self-cooling of
not permitted and therefore limiting type coupling is bearings where ood lubrication is standard. Those
needed to ensure rotor location within axial oat range. units requiring ood lubrication are supplied with
On request, when special axial oat is at least 3 mm, provisions only. Refer oil supply pressure, type of oil,
magnetic running center can be adjusted within and location of provisions to factory for review prior to
2.4 mm from mechanical center (option). order acceptance.

Table below: Sleeve bearings and lubrication method.

Frame size Poles D-end bearing N-end bearing Lubrication Method

HXR 355 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)


HXR 355 4 EFZLB 9-90 EFZLQ 9-90 Self lubrication
HXR 400 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)
HXR 400 4 EFZLB 9-100 EFZLQ 9-100 Self lubrication
HXR 450 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)
HXR 450 4 EFZLB 9-100 EFZLQ 9-100 Oil circulation 1)
HXR 450 6 EFZLB 9-100 EFZLQ 9-100 Self lubrication
HXR 500 2 EFZLB 9-90 EFZLQ 9-90 Oil circulation 1)
HXR 500 4 EFZLB 11-100 EFZLQ 9-100 Oil circulation 1)
HXR 500 6 EFZLB 11-100 EFZLQ 9-100 Self lubrication
HXR 560 2 EFZLB 14-125 EFZLQ 14-125 Oil circulation
HXR 560
HXR 560
4
6
EFZLB 14-125
EFZLB 14-125
EFZLQ 14-125
EFZLQ 14-125
Oil circulation 1)
Self lubrication
5
HXR 560 8 EFZLB 14-140 EFZLQ 14-140 Self lubrication
AMA 400 2 EFZLB 9-80 EFZLQ 9-80 Self lubrication
AMA 400 4 EFZLB 9-100 EFZLQ 9-100 Self lubrication
AMA 450 2 EFZLB 9-80 EFZLQ 9-80 Self lubrication
AMA 450 4 EFZLB 11-125 EFZLQ 9-100 Self lubrication
AMA 500 2 EFZLB 9-100 EFZLQ 9-100 Oil circulation 1)
AMA 500 4 EFZLB 14-125 EFZLQ 11-125 Self lubrication
AMA 500 6 EFZLB 14-140 EFZLQ 11-125 Self lubrication
1)
Possibility for self lubrication, please contact ABB

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 127


Vertical motors
Vertical motors 355 - 500 have deep groove ball bearing Standard bearing solution is designed to carry the
in D-end and single-row angular contact ball bearing in weight of the typical coupling half and the weight of
N-end. the motor rotor only. Any additional radial or axial
force caused by driven equipment may require special
The bearing in D-end is axially free in vertical motors
bearing construction.
when an angular contact ball bearing is mounted in
N-end. Standard bearings of vertical motors are stated
in table below and the bearing construction is shown in
gure below.

Table below: Standard bearings for vertical motors.

Frame size Poles D-end N-end

HXR 355 2 6317M/C3 7317 BMP 1)


HXR 355 4 6322/C3 7319 BMP
HXR 400 2 6317M/C3 7317 BMP 2)
HXR 400 4 6324/C3 7319 BMP
HXR 450 4 6324/C3 7322 BMP
HXR 500 4 6326/C3 7324 BMP
AMA 400 4 6324/C3 7319 BMP
AMA 450 4 6326/C3 7322 BMP
AMA 500 4 6330/C3 7324 BMP
1)
60 Hz motors have ball bearing 6317M/C3.
2)
Only for 50 Hz motors.

Figure below: Standard bearing construction of vertically mounted motor, frame sizes 355 - 500. On the left the
bearing is "axially locked" angular contact ball bearing and on the right is an axially free deep

5 groove ball bearing.

1 Bearing 5 Circlip
2 Inner bearing cover 6 Hexagon screw
3 Grease valve 7 Spring
4 Outer bearing cover 8 O-ring

128 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Bearing rating life
The bearing rates for all vertical motors with standard bearings will complete or exceed before the rst
bearings have a rated life time L10h in excess of evidence of failure.
100000 h. The life times are calculated in accordance
Additional axial force from the driven equipment is not
with ISO R 281-1.
allowed.
The basic rated life L10h is the number of hours at rated
bearing load and speed that 90% of a group of identical

Lubrication intervals
The motors are equipped with greasing nipple(s) in relubrication plate. The values are also available in the
both ends for lubricating the bearings. The amount of table on page 126.
grease and the interval of greasing are stamped on the

Vibrations
Standard design
The standard motors manufactured according to IEC- Other vibration limit specication, such as IEC 60034-14
standard satisfy the Grade A vibration limits found in Grade B, NEMA special motor or API 541, are available
IEC 60034-14. The table below shows the maximum on request.
accepted values.

Table below: Standard design unltered vibration limits for IEC motors.

Poles Speed [rpm] Bearing housing


vibration
Relative shaft
vibration
Combined runout 5
2 1800 < n 3600 2.3 mm/s rms 65 m p-p 16 m p-p
4 n 1800 2.3 mm/s rms 90 m p-p 23 m p-p

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 129


Notes
All ratings in this catalogue are designed for the
following:
- Class F insulation / Maximum temperature rise of
80 C by resistance
- Maximum 40 C ambient
- Altitude of 1000 meters or less
- Data presented in rating lists are typical values.
Guaranteed values are available on request.
All engineered motors are optimized for the
specied application. Accurate motor data will be
given on request at quotation phase. Legally binding
performance and specication data is given to the end
user once each order is conrmed.
- Please provide load data and starting requirements to
ABB for nal design conrmation.

130 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


100 HXR 355LA2 2963 93.1 92.5 0.91 0.90 23 5.8 6 322 0.7 2.4 2.7 1570 85
125 HXR 355LA2 2967 93.8 93.4 0.91 0.90 28 6.1 7 402 0.7 2.6 2.7 1570 85
160 HXR 355LA2 2967 94.5 94.3 0.92 0.91 35 6.1 8 515 0.7 2.5 3.0 1650 85
200 HXR 355LA2 2967 94.9 94.8 0.93 0.92 44 6.1 9 644 0.7 2.5 3.0 1650 85
224 HXR 355LA2 2968 95.1 95.1 0.92 0.90 49 6.1 11 721 0.7 2.5 3.0 1650 85
250 HXR 355LB2 2969 95.4 95.3 0.92 0.90 55 6.2 13 804 0.7 2.5 3.1 1700 85
280 HXR 355LB2 2971 95.6 95.6 0.91 0.90 62 6.4 15 900 0.7 2.6 3.3 1750 85
315 HXR 355LD2 2970 95.8 95.9 0.93 0.92 68 6.5 14 1013 0.7 2.6 3.7 1890 85
355 HXR 400LC2 2981 96.2 95.9 0.90 0.89 79 6.8 20 1137 0.6 2.7 5.7 2590 82
400 HXR 400LD2 2980 96.3 96.1 0.91 0.89 88 6.7 21 1282 0.6 2.7 6.0 2630 82
450 HXR 400LE2 2982 96.5 96.4 0.90 0.89 100 6.7 24 1441 0.6 2.5 6.8 2810 82
500 HXR 400LF2 2982 96.6 96.5 0.90 0.89 110 6.7 26 1601 0.6 2.5 7.3 2930 82
560 HXR 400LG2 2982 96.8 96.7 0.91 0.89 123 6.9 28 1793 0.7 2.6 7.8 3050 82
630 HXR 450LG2 2984 96.7 96.5 0.92 0.90 136 7.3 32 2016 0.6 2.9 11.9 4000 85
710 HXR 450LJ2 2983 96.9 96.8 0.93 0.92 151 7.3 31 2273 0.7 2.8 13.9 4390 85
800 HXR 500LH2 2989 96.8 96.5 0.91 0.89 175 7.4 44 2556 0.6 3.0 23.7 5820 86
900 HXR 500LK2 2986 96.9 96.8 0.93 0.92 192 7.0 38 2878 0.6 2.7 25.8 6110 86
1000 HXR 500LL2 2988 97.1 96.9 0.92 0.91 215 7.2 46 3196 0.6 2.8 27.7 6380 86
1120 HXR 500LP2 2988 97.2 97.0 0.91 0.90 243 7.3 54 3579 0.7 2.8 31.4 6860 86
1250
1400
HXR 500LR2
HXR 560LM2
2989
2989
97.4
97.4
97.3
97.2
0.93
0.92
0.92
0.91
265 7.5
300 7.3
53
70
3993
4473
0.6
0.6
2.9
2.9
32.8
45.6
7220
9810
86
87
5
1600 HXR 560LR2 2990 97.6 97.4 0.93 0.92 339 7.3 72 5111 0.6 2.9 53.0 10790 87
1730 HXR 560LS2 2991 97.6 97.5 0.92 0.91 370 7.6 84 5524 0.6 3.0 58.0 11360 87

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 131


HV Pressurized cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1500 r/min = 4 poles 3000 V 50 Hz


100 HXR 355LA4 1487 93.9 93.2 0.83 0.79 25 6.1 10 642 1.0 2.4 4.7 1620 77
125 HXR 355LA4 1485 94.3 93.9 0.84 0.80 30 6.0 12 804 1.0 2.3 4.8 1620 77
160 HXR 355LA4 1485 94.8 94.5 0.85 0.82 38 6.1 14 1029 1.0 2.3 4.8 1630 77
200 HXR 355LA4 1484 95.0 94.9 0.85 0.82 48 5.9 17 1287 1.0 2.2 4.8 1630 77
224 HXR 355LA4 1485 95.3 95.2 0.85 0.82 53 6.0 18 1441 1.0 2.2 5.1 1670 77
250 HXR 355LB4 1485 95.5 95.4 0.85 0.82 59 6.1 21 1607 1.0 2.2 5.4 1720 77
280 HXR 355LB4 1486 95.7 95.6 0.84 0.81 67 6.2 24 1799 1.0 2.2 5.7 1770 77
315 HXR 355LC4 1487 95.9 95.8 0.84 0.81 75 6.2 27 2023 1.0 2.2 6.3 1870 77
355 HXR 355LE4 1487 96.1 96.1 0.85 0.82 84 6.2 29 2279 1.0 2.1 7.2 2020 77
400 HXR 400LC4 1491 96.4 96.3 0.86 0.83 93 6.1 31 2562 0.8 2.2 11.4 2630 76
450 HXR 400LD4 1490 96.6 96.6 0.87 0.85 103 6.0 31 2884 0.8 2.1 12.5 2750 76
500 HXR 400LE4 1490 96.7 96.7 0.88 0.86 113 6.0 32 3204 0.8 2.1 13.6 2880 76
560 HXR 400LG4 1491 96.9 96.8 0.87 0.85 128 6.5 40 3586 0.9 2.2 15.2 3070 76
630 HXR 400LH4 1491 97.0 97.0 0.88 0.86 143 6.5 43 4034 0.9 2.2 16.8 3270 76
710 HXR 450LG4 1492 97.1 97.1 0.88 0.86 160 6.4 48 4545 0.8 2.3 26.7 4170 77
800 HXR 450LJ4 1492 97.2 97.2 0.88 0.86 180 6.4 52 5120 0.8 2.2 29.4 4420 77
900 HXR 450LL4 1492 97.3 97.3 0.88 0.86 201 6.5 58 5760 0.9 2.2 33.0 4740 77
1000 HXR 500LJ4 1491 97.2 97.3 0.90 0.88 220 6.5 58 6404 0.7 2.4 48.5 6010 77

5
1120 HXR 500LK4 1492 97.4 97.4 0.90 0.89 245 6.3 62 7167 0.7 2.3 53.1 6310 77
1250 HXR 500LL4 1492 97.4 97.5 0.90 0.89 274 6.2 68 7998 0.7 2.2 55.8 6510 77
1400 HXR 500LP4 1493 97.6 97.6 0.89 0.88 308 6.4 83 8953 0.7 2.3 63.7 7090 77
1600 HXR 560LK4 1494 97.7 97.7 0.90 0.88 351 6.7 95 10229 0.7 2.4 89.4 9410 82
1800 HXR 560LP4 1495 97.8 97.7 0.89 0.87 399 6.9 119 11500 0.7 2.5 107.7 10330 82
2000 HXR 560LS4 1495 97.9 97.9 0.89 0.87 440 7.1 127 12777 0.7 2.5 127.5 11350 82
2240 HXR 560LT4 1496 98.0 97.9 0.87 0.85 504 7.2 161 14298 0.7 2.4 139.7 11980 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

132 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


160 HXR 355LA6 988 94.6 94.5 0.78 0.74 42 5.2 19 1546 1.1 2.0 5.4 1660 75
180 HXR 355LB6 988 94.9 94.9 0.79 0.74 46 5.4 21 1740 1.2 2.0 5.7 1700 75
200 HXR 355LC6 988 95.1 95.1 0.80 0.76 50 5.2 21 1934 1.2 1.9 6.3 1800 75
224 HXR 355LC6 988 95.3 95.3 0.80 0.76 57 5.4 24 2165 1.2 1.9 6.6 1850 75
250 HXR 355LD6 988 95.4 95.5 0.80 0.76 63 5.4 26 2416 1.2 1.9 7.3 1940 75
280 HXR 355LE6 989 95.6 95.6 0.80 0.76 71 5.7 30 2704 1.3 2.0 7.9 2040 75
315 HXR 355LF6 991 96.0 95.9 0.78 0.73 81 5.8 38 3036 1.1 2.1 8.2 2100 75
355 HXR 400LD6 992 96.1 96.1 0.83 0.79 86 5.9 32 3417 1.1 2.0 18.4 2710 75
400 HXR 400LF6 993 96.3 96.3 0.83 0.80 96 6.0 36 3848 1.1 2.0 20.9 2900 75
450 HXR 400LH6 993 96.4 96.4 0.83 0.79 109 6.1 41 4327 1.0 2.0 24.2 3140 75
500 HXR 400LK6 994 96.6 96.5 0.82 0.78 122 6.3 50 4804 1.0 2.1 28.2 3460 75
560 HXR 450LF6 993 96.8 96.8 0.85 0.83 131 5.8 42 5388 1.0 2.0 34.9 3970 76
630 HXR 450LH6 993 96.8 96.9 0.86 0.83 146 5.9 47 6060 1.0 2.0 38.9 4200 76
710 HXR 450LK6 993 97.0 97.0 0.86 0.83 165 6.0 53 6828 1.0 2.0 44.2 4540 76
800 HXR 450LM6 994 97.1 97.1 0.85 0.83 186 6.1 62 7689 1.0 2.0 50.7 4930 76
900 HXR 500LG6 994 97.1 97.2 0.86 0.84 207 6.0 66 8648 0.9 2.1 58.3 5680 77
1000 HXR 500LJ6 994 97.2 97.3 0.87 0.85 228 5.9 68 9611 0.9 2.0 66.3 6080 77
1120 HXR 500LN6 994 97.4 97.4 0.86 0.84 256 6.1 83 10754 0.9 2.1 81.6 6860 77
1250 HXR 500LQ6 995 97.5 97.5 0.86 0.83 288 6.3 98 11998 0.9 2.2 89.1 7250 77
1400
1600
HXR 500LS6
HXR 560LN6
995
995
97.5
97.6
97.5
97.6
0.84
0.87
0.81
0.84
328 6.5 122
363 6.5 118
13431 0.9
15348 0.8
2.3
2.3
97.9
142.1
7690
10060
77
81
5
1800 HXR 560LR6 996 97.7 97.7 0.87 0.84 409 6.7 135 17262 0.8 2.4 169.5 11060 81
2000 HXR 560LU6 996 97.8 97.8 0.88 0.86 445 6.7 133 19171 0.7 2.4 207.4 12330 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 133


HV Pressurized cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

750 r/min = 8 poles 3000 V 50 Hz


200 HXR 400LB8 741 94.9 95.1 0.81 0.78 50 4.9 20 2577 0.9 1.9 15.2 2460 75
224 HXR 400LC8 741 95.1 95.3 0.82 0.78 55 5.0 21 2886 1.0 1.9 16.9 2580 75
250 HXR 400LE8 741 95.4 95.6 0.83 0.79 61 5.0 23 3221 1.0 1.9 19.4 2770 75
280 HXR 400LF8 742 95.5 95.7 0.83 0.79 68 5.0 26 3606 1.0 1.9 21.9 2950 75
315 HXR 400LH8 742 95.7 95.9 0.82 0.78 78 5.2 31 4052 1.0 2.0 24.3 3140 75
355 HXR 400LJ8 742 95.8 96.0 0.82 0.79 86 5.1 33 4568 1.0 1.9 26.9 3330 75
400 HXR 450LD8 743 95.9 96.0 0.83 0.80 96 5.3 35 5143 0.9 2.0 30.1 3610 78
450 HXR 450LE8 743 96.0 96.1 0.83 0.80 108 5.3 40 5786 0.9 2.0 31.5 3700 75
500 HXR 450LG8 743 96.2 96.3 0.83 0.80 120 5.5 44 6423 1.0 2.0 38.2 4100 75
560 HXR 450LH8 744 96.3 96.3 0.83 0.79 135 5.5 52 7192 0.9 2.0 40.9 4260 75
630 HXR 450LL8 744 96.4 96.4 0.82 0.79 153 5.7 60 8085 1.0 2.1 48.9 4720 75
710 HXR 500LF8 745 96.4 96.4 0.82 0.78 173 5.6 68 9101 0.9 2.0 55.2 5470 75
800 HXR 500LH8 745 96.5 96.5 0.82 0.78 194 5.6 75 10253 0.9 2.0 61.2 5780 75
900 HXR 500LK8 745 96.7 96.6 0.82 0.78 218 5.7 85 11532 0.9 2.0 69.2 6170 75
1000 HXR 500LN8 745 96.6 96.6 0.82 0.79 242 5.5 90 12822 1.0 1.9 80.4 6740 75
1120 HXR 500LP8 745 96.8 96.8 0.83 0.80 268 5.7 97 14353 0.9 1.9 85.2 6910 75
1250 HXR 500LR8 745 96.9 96.9 0.82 0.79 301 5.7 113 16013 0.9 1.9 94.9 7430 75
1400 HXR 560LN8 746 97.3 97.3 0.82 0.78 339 5.9 137 17918 0.8 2.1 144.0 10050 78
1600 HXR 560LR8 747 97.5 97.4 0.82 0.78 387 6.1 154 20460 0.9 2.0 173.3 11020 78
5 1800 HXR 560LU8 747 97.6 97.5 0.81 0.77 440 6.0 180 23009 0.8 2.0 211.5 12390 78

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

134 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


160 HXR 400LC10 594 94.2 94.0 0.71 0.64 46 4.8 26 2572 1.0 2.0 16.9 2580 75
180 HXR 400LD10 594 94.4 94.2 0.72 0.66 51 4.8 27 2895 1.0 2.0 18.7 2710 75
200 HXR 400LE10 594 94.6 94.3 0.72 0.65 57 4.8 31 3215 1.0 2.0 19.8 2800 75
224 HXR 400LF10 594 94.7 94.6 0.72 0.66 63 4.8 34 3601 1.0 2.0 22.0 2970 75
250 HXR 400LH10 594 94.9 94.7 0.72 0.66 70 4.9 37 4018 1.0 2.0 24.5 3160 75
280 HXR 400LK10 594 95.1 94.9 0.73 0.67 78 4.9 41 4499 1.0 2.0 28.4 3450 75
315 HXR 450LG10 595 95.8 95.8 0.76 0.70 83 5.2 41 5059 1.0 2.1 38.3 4090 75
355 HXR 450LJ10 595 95.9 96.0 0.76 0.71 93 5.2 45 5701 1.0 2.0 42.4 4330 75
400 HXR 450LK10 595 96.1 96.1 0.76 0.70 105 5.3 52 6422 1.0 2.1 46.5 4570 75
450 HXR 450LM10 595 96.2 96.1 0.75 0.70 120 5.4 60 7222 1.0 2.1 51.9 4900 75
500 HXR 500LH10 595 96.5 96.6 0.78 0.73 128 5.2 59 8026 0.9 2.1 62.9 5860 75
560 HXR 500LK10 595 96.5 96.6 0.79 0.74 142 5.1 62 8990 0.9 2.0 70.9 6220 75
630 HXR 500LM10 595 96.6 96.7 0.79 0.74 159 5.2 70 10113 0.9 2.0 78.9 6610 75
710 HXR 500LN10 595 96.6 96.7 0.79 0.75 179 5.0 75 11402 0.9 1.9 82.9 6820 75
800 HXR 500LP10 594 96.6 96.8 0.79 0.76 201 4.9 82 12851 0.9 1.9 86.9 7010 75
900 HXR 500LR10 595 96.7 96.8 0.79 0.75 227 5.2 98 14448 0.9 2.0 99.0 7600 75
1000 HXR 560LN10 597 97.0 97.0 0.77 0.73 256 5.0 114 16006 0.7 1.9 145.4 10030 77
1120 HXR 560LQ10 597 97.1 97.0 0.77 0.72 289 5.3 135 17921 0.8 2.0 159.7 10520 77
1250 HXR 560LS10 597 97.1 97.1 0.78 0.74 318 5.1 139 20006 0.7 1.9 181.2 11270 77
1400 HXR 560LU10 597 97.2 97.0 0.75 0.69 368 6.0 187 22384 0.9 2.2 213.3 12390 77

500 r/min = 12 poles


140 HXR 400LD12 494
3000 V 50 Hz
93.6 93.4 0.68 0.61 42 4.3 25 2707 1.0 1.8 18.6 2710 75
5
160 HXR 400LE12 494 93.8 93.7 0.69 0.62 48 4.2 27 3094 1.0 1.8 20.3 2830 75
180 HXR 400LG12 494 94.0 93.9 0.70 0.64 53 4.1 29 3482 1.0 1.7 22.8 3030 75
200 HXR 400LH12 494 94.0 93.8 0.70 0.64 59 4.2 32 3867 1.0 1.8 25.4 3210 75
224 HXR 400LK12 494 94.1 93.8 0.68 0.61 67 4.3 39 4327 1.0 1.8 27.7 3390 75
250 HXR 450LH12 495 94.9 94.7 0.71 0.65 72 4.3 38 4827 0.9 1.8 39.7 4180 75
280 HXR 450LJ12 494 95.0 94.9 0.72 0.66 79 4.2 40 5408 0.8 1.7 42.5 4370 75
315 HXR 450LL12 495 95.1 95.0 0.72 0.66 89 4.3 46 6081 0.9 1.8 49.3 4750 75
355 HXR 450LM12 495 95.1 95.0 0.71 0.66 101 4.3 53 6853 0.9 1.8 52.0 4910 75
400 HXR 500LJ12 495 95.5 95.4 0.71 0.65 113 4.4 60 7717 0.9 1.8 66.5 6040 75
450 HXR 500LL12 495 95.6 95.5 0.72 0.66 126 4.4 65 8683 0.9 1.8 72.6 6340 75
500 HXR 500LN12 495 95.7 95.6 0.72 0.67 139 4.4 71 9648 0.9 1.8 80.6 6740 75
560 HXR 500LQ12 495 95.6 95.5 0.72 0.66 157 4.4 81 10803 0.9 1.8 88.5 7100 75
630 HXR 500LR12 495 95.7 95.6 0.72 0.67 175 4.4 88 12157 0.9 1.8 92.6 7300 75
710 HXR 500LS12 495 95.8 95.7 0.72 0.66 199 4.5 103 13695 0.9 1.8 104.5 7890 75
800 HXR 560LM12 496 96.5 96.6 0.77 0.72 207 4.5 94 15407 0.7 1.9 133.9 9610 75
900 HXR 560LQ12 496 96.6 96.6 0.78 0.74 230 4.4 99 17335 0.7 1.8 158.8 10450 75
1000 HXR 560LS12 496 96.7 96.7 0.77 0.72 257 4.8 119 19247 0.7 2.0 180.2 11210 75
1120 HXR 560LU12 497 96.9 96.8 0.75 0.69 296 5.1 148 21512 0.8 2.0 213.4 12320 75
Data presented in rating lists are typical values.
Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 135


HV Pressurized cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


160 HXR 355LB2 2966 94.3 94.0 0.89 0.86 18 6.6 6 515 0.8 2.9 2.2 1670 85
180 HXR 355LB2 2962 94.3 94.2 0.90 0.88 20 6.2 6 580 0.7 2.7 2.2 1670 85
200 HXR 355LB2 2966 94.7 94.6 0.90 0.88 23 6.5 6 644 0.7 2.8 2.3 1720 85
224 HXR 355LB2 2968 94.9 94.8 0.89 0.87 25 6.6 7 721 0.7 2.8 2.4 1760 85
250 HXR 355LC2 2971 95.2 95.1 0.89 0.88 28 6.7 7 804 0.9 2.5 3.7 1810 85
280 HXR 355LD2 2978 95.5 95.4 0.90 0.88 31 6.9 8 898 0.7 2.7 3.7 1840 85
315 HXR 400LC2 2976 95.6 95.4 0.89 0.87 36 6.7 9 1011 0.8 2.5 6.0 2540 82
355 HXR 400LC2 2981 95.9 95.8 0.91 0.89 39 6.9 10 1137 0.7 2.8 5.7 2530 82
400 HXR 400LD2 2981 96.2 96.1 0.92 0.91 44 6.9 10 1281 0.6 2.7 6.1 2640 82
450 HXR 400LF2 2982 96.5 96.4 0.92 0.91 49 6.9 11 1441 0.6 2.7 7.1 2880 82
500 HXR 400LG2 2983 96.6 96.5 0.91 0.90 55 6.9 12 1601 0.6 2.6 7.4 2940 82
560 HXR 450LF2 2984 96.5 96.3 0.93 0.91 60 7.4 13 1792 0.7 3.0 11.5 3870 85
630 HXR 450LH2 2984 96.7 96.6 0.93 0.92 67 7.2 14 2016 0.7 2.8 13.0 4170 85
690 HXR 450LK2 2984 96.8 96.7 0.93 0.92 74 7.3 15 2208 0.7 2.8 14.2 4410 85
710 HXR 500LG2 2988 96.6 96.3 0.91 0.90 77 7.3 19 2269 0.6 2.9 22.4 5570 86
800 HXR 500LH2 2987 96.7 96.5 0.92 0.91 86 7.3 19 2557 0.6 2.8 23.8 5760 86
900 HXR 500LL2 2988 96.9 96.7 0.92 0.91 97 7.2 21 2877 0.6 2.8 27.0 6230 86
1000 HXR 500LN2 2987 97.1 97.0 0.93 0.93 106 7.1 20 3197 0.6 2.7 30.3 6690 86
1120 HXR 500LQ2 2988 97.2 97.1 0.92 0.91 121 7.3 26 3579 0.6 2.7 32.2 6970 86
5 1250
1400
HXR 560LM2
HXR 560LN2
2986
2989
97.1
97.3
97.0
97.2
0.92
0.92
0.91
0.90
134 7.4
151 7.4
32
36
3997
4473
0.6
0.6
3.0
2.9
46.2
48.4
9680
10030
87
87
1600 HXR 560LS2 2991 97.5 97.3 0.91 0.89 174 7.4 43 5109 0.6 2.8 59.2 11230 87

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

136 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1500 r/min = 4 poles 6000 V 50 Hz


160 HXR 355LA4 1487 94.6 94.3 0.82 0.77 20 5.6 8 1028 0.9 2.2 4.0 1720 77
180 HXR 355LA4 1486 94.7 94.5 0.81 0.77 23 5.4 9 1157 0.8 2.0 4.0 1730 77
200 HXR 355LA4 1486 94.9 94.8 0.83 0.79 25 5.3 10 1285 0.8 2.1 4.0 1730 77
224 HXR 355LC4 1486 95.0 94.9 0.82 0.79 28 5.3 11 1440 0.8 2.1 4.0 1730 77
250 HXR 355LC4 1486 95.3 95.3 0.83 0.80 30 5.5 11 1606 0.8 2.1 4.4 1830 77
280 HXR 355LC4 1487 95.4 95.3 0.84 0.81 34 6.5 13 1798 1.1 2.3 6.0 1780 77
315 HXR 355LE4 1488 95.6 95.6 0.85 0.81 37 6.5 14 2021 1.1 2.3 7.2 1970 77
355 HXR 400LC4 1486 96.0 96.0 0.86 0.84 41 5.2 13 2281 0.7 2.0 7.2 2530 76
400 HXR 400LD4 1487 96.2 96.2 0.86 0.83 47 5.5 15 2568 0.8 2.1 7.9 2660 76
450 HXR 400LD4 1490 96.5 96.5 0.87 0.85 52 6.2 16 2884 0.9 2.2 12.5 2720 76
500 HXR 400LE4 1490 96.6 96.6 0.88 0.86 57 6.1 17 3204 0.9 2.1 13.6 2850 76
560 HXR 400LG4 1491 96.8 96.8 0.87 0.85 64 6.3 19 3587 0.9 2.2 15.7 3100 76
630 HXR 450LE4 1492 96.9 96.8 0.87 0.84 72 6.6 24 4031 0.8 2.4 22.9 3810 77
710 HXR 450LG4 1492 97.0 97.0 0.88 0.86 80 6.4 24 4545 0.8 2.3 26.7 4130 77
800 HXR 450LJ4 1492 97.2 97.2 0.88 0.87 90 6.3 25 5121 0.8 2.2 30.3 4450 77
900 HXR 500LF4 1491 97.1 97.1 0.89 0.87 100 6.1 28 5763 0.8 2.2 40.0 5430 77
1000 HXR 500LG4 1492 97.2 97.2 0.89 0.87 112 6.2 32 6401 0.8 2.2 44.0 5690 77
1120 HXR 500LJ4 1493 97.3 97.3 0.88 0.86 125 6.6 37 7165 0.8 2.3 49.5 6080 77
1250 HXR 500LP4 1493 97.5 97.5 0.88 0.86 140 6.5 42 7994 0.8 2.3 63.3 7030 77
1400
1600
HXR 500LR4
HXR 560LM4
1493
1495
97.6
97.7
97.6
97.6
0.88
0.89
0.86
0.86
157 6.5
178 6.9
47
54
8952
10223
0.7
0.7
2.3
2.5
68.7
95.6
7420
9670
77
82
5
1800 HXR 560LR4 1495 97.8 97.7 0.89 0.87 199 6.9 58 11499 0.7 2.5 122.4 10970 82
2000 HXR 560LT4 1496 97.9 97.8 0.88 0.86 224 7.0 68 12767 0.7 2.3 137.5 11730 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 137


HV Pressurized cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


125 HXR 355LC6 991 94.4 93.9 0.74 0.67 17 6.0 10 1204 1.0 2.8 4.8 1810 75
160 HXR 355LC6 988 94.5 94.4 0.78 0.73 21 5.0 10 1546 0.8 2.2 4.8 1810 75
180 HXR 355LD6 988 94.6 94.6 0.78 0.73 23 4.9 11 1740 0.7 2.1 4.8 1820 75
200 HXR 355LD6 987 94.7 94.8 0.79 0.74 26 4.7 12 1934 0.7 2.0 5.0 1870 75
224 HXR 355LD6 990 95.0 94.9 0.79 0.74 29 5.9 13 2161 1.3 2.2 7.3 1910 75
250 HXR 355LE6 989 95.2 95.2 0.80 0.76 31 5.7 13 2414 1.3 2.0 7.9 2000 75
280 HXR 400LC6 991 95.7 95.7 0.82 0.77 35 5.9 15 2698 1.0 2.2 11.2 2490 75
315 HXR 400LC6 991 95.8 95.8 0.83 0.79 38 5.8 15 3037 1.0 2.1 11.8 2560 75
355 HXR 400LD6 991 96.0 96.0 0.82 0.78 43 5.8 18 3421 1.0 2.1 12.9 2680 75
400 HXR 400LF6 992 96.2 96.2 0.82 0.77 49 5.9 20 3852 1.0 2.2 14.5 2870 75
450 HXR 400LJ6 992 96.4 96.4 0.83 0.79 54 6.0 21 4332 1.0 2.2 17.8 3250 75
450 HXR 450LD6 992 96.3 96.4 0.85 0.82 53 6.0 19 4330 1.0 2.1 28.3 3520 76
560 HXR 450LF6 993 96.6 96.7 0.86 0.83 65 6.0 21 5388 1.1 2.0 35.0 3920 76
630 HXR 450LH6 993 96.7 96.8 0.86 0.83 73 6.0 24 6060 1.1 2.0 38.9 4160 76
710 HXR 450LK6 994 96.9 96.9 0.84 0.81 84 6.4 30 6822 1.1 2.1 45.3 4520 76
800 HXR 500LH6 994 97.0 96.9 0.83 0.80 95 5.8 36 7685 0.8 2.1 59.2 5690 77
900 HXR 500LJ6 994 97.0 97.1 0.84 0.81 107 5.7 38 8647 0.8 2.0 63.0 5890 77
1000 HXR 500LK6 994 97.1 97.2 0.84 0.82 117 5.8 40 9609 0.9 2.0 69.0 6180 77

5
1120 HXR 500LN6 994 97.3 97.3 0.84 0.80 132 6.1 48 10755 0.9 2.1 80.4 6760 77
1250 HXR 500LR6 995 97.4 97.4 0.85 0.82 145 6.2 52 11995 0.8 2.2 92.5 7350 77
1400 HXR 560LM6 996 97.5 97.4 0.86 0.82 161 6.8 58 13423 0.8 2.5 134.5 9720 81
1600 HXR 560LR6 996 97.6 97.5 0.85 0.81 186 6.9 71 15334 0.8 2.5 161.0 10670 81
1800 HXR 560LU6 996 97.6 97.7 0.87 0.85 203 6.7 66 17260 0.8 2.4 204.3 12160 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

138 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

750 r/min = 8 poles 6000 V 50 Hz


180 HXR 400LC8 741 94.4 94.4 0.77 0.72 24 4.7 11 2319 1.0 1.9 11.7 2520 75
200 HXR 400LD8 742 94.7 94.7 0.76 0.71 27 4.8 13 2575 1.0 1.9 12.8 2650 75
224 HXR 400LE8 741 94.8 94.9 0.78 0.74 29 4.8 13 2887 1.0 1.9 13.9 2780 75
250 HXR 400LF8 741 94.9 95.1 0.80 0.76 32 4.7 13 3224 1.0 1.8 15.1 2900 75
280 HXR 400LH8 741 95.2 95.3 0.79 0.75 36 4.8 15 3607 1.0 1.9 17.3 3150 75
315 HXR 400LJ8 741 95.2 95.2 0.78 0.74 41 4.8 18 4057 1.0 1.9 17.8 3220 75
355 HXR 450LD8 743 95.5 95.6 0.84 0.81 43 5.3 15 4565 0.9 2.0 30.1 3570 75
400 HXR 450LF8 743 95.8 95.8 0.83 0.80 48 5.4 18 5140 0.9 2.1 34.1 3810 75
450 HXR 450LG8 743 95.9 95.9 0.84 0.80 54 5.4 20 5783 0.9 2.0 36.8 3970 75
500 HXR 450LK8 744 96.1 96.1 0.84 0.80 60 5.6 22 6420 1.0 2.1 46.3 4530 75
560 HXR 450LM8 744 96.2 96.2 0.84 0.80 67 5.6 25 7190 0.9 2.1 51.7 4850 75
630 HXR 450LN8 745 96.4 96.2 0.81 0.77 77 6.2 33 8075 1.0 2.4 53.1 4930 75
710 HXR 500LJ8 745 96.3 96.2 0.83 0.80 85 5.9 33 9102 0.9 2.2 67.0 5970 75
800 HXR 500LK8 745 96.4 96.3 0.83 0.80 96 5.9 37 10257 0.9 2.2 69.1 6080 75
900 HXR 500LL8 745 96.4 96.4 0.84 0.80 107 5.7 40 11542 0.9 2.1 73.1 6270 75
1000 HXR 500LP8 745 96.6 96.5 0.84 0.80 119 5.9 45 12819 0.9 2.2 85.0 6860 75
1120 HXR 500LS8 745 96.7 96.7 0.84 0.80 132 6.1 50 14352 0.9 2.2 105.0 7830 78
1250 HXR 560LM8 746 97.1 97.2 0.82 0.78 151 5.7 59 16002 0.8 2.0 136.9 9700 78
1400 HXR 560LQ8 747 97.2 97.2 0.81 0.76 172 6.6 76 17907 1.0 2.4 158.1 10390 78
1600 HXR 560LU8 747 97.4 97.2 0.79 0.74 199 6.4 93 20454 0.9 2.4 206.0 12110 78 5

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 139


HV Pressurized cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


224 HXR 450LD10 595 95.1 95.0 0.74 0.68 31 5.3 16 3596 1.0 2.1 30.1 3550 75
250 HXR 450LE10 595 95.2 95.2 0.75 0.69 34 5.2 17 4015 1.0 2.1 32.8 3710 75
280 HXR 450LF10 595 95.3 95.4 0.76 0.70 37 5.2 18 4497 1.0 2.1 35.6 3860 75
315 HXR 450LG10 595 95.5 95.5 0.76 0.70 42 5.2 21 5059 1.0 2.1 38.3 4030 75
355 HXR 450LJ10 594 95.6 95.7 0.78 0.72 46 5.2 21 5703 1.0 2.0 43.8 4340 75
400 HXR 450LK10 595 95.7 95.7 0.76 0.71 53 5.3 26 6422 1.1 2.1 46.5 4500 75
450 HXR 450LM10 595 95.8 95.8 0.76 0.70 60 5.4 30 7222 1.0 2.1 51.9 4820 75
500 HXR 500LJ10 594 96.2 96.3 0.78 0.74 64 5.0 28 8038 1.0 1.9 64.6 5890 75
560 HXR 500LL10 594 96.3 96.4 0.79 0.74 71 5.1 31 9001 1.0 1.9 74.6 6370 75
630 HXR 500LM10 595 96.3 96.3 0.79 0.75 80 5.1 34 10116 0.9 2.0 78.9 6540 75
710 HXR 500LP10 595 96.3 96.4 0.79 0.75 89 5.0 37 11405 0.9 1.9 84.9 6830 75
800 HXR 500LQ10 594 96.4 96.5 0.80 0.76 100 4.9 41 12852 0.9 1.9 90.9 7120 75
900 HXR 500LS10 596 96.4 96.3 0.75 0.69 120 5.3 60 14414 1.0 2.0 101.1 7610 75
1000 HXR 560LN10 597 96.9 96.8 0.78 0.73 128 5.0 57 16006 0.7 1.9 145.4 9910 77
1120 HXR 560LR10 597 97.0 96.8 0.75 0.70 147 5.8 75 17910 0.9 2.2 174.0 10900 77
1250 HXR 560LU10 597 97.0 96.9 0.77 0.72 161 5.7 77 19991 0.8 2.1 209.7 12070 77

500 r/min = 12 poles 6000 V 50 Hz


140 HXR 400LG12 493 92.9 92.4 0.63 0.56 23 3.7 15 2710 0.8 1.9 16.5 3020 75

5 180
160
HXR 400LJ12
HXR 450LF12
496
496
93.3
94.0
92.7
93.4
0.65
0.62
0.57
0.55
29
26
4.7
4.2
18
17
3469
3082
1.1
0.8
2.1
2.0
26.2
27.1
3200
3970
75
75
200 HXR 450LF12 494 94.2 94.0 0.67 0.61 30 3.6 17 3863 0.6 1.6 27.1 3970 75
224 HXR 450LG12 495 94.4 94.3 0.71 0.65 32 4.3 17 4324 0.9 1.8 38.4 4040 75
250 HXR 450LJ12 495 94.6 94.4 0.71 0.65 36 4.3 19 4824 0.8 1.8 43.8 4360 75
280 HXR 450LK12 495 94.7 94.5 0.71 0.66 40 4.3 21 5405 0.9 1.8 46.6 4520 75
315 HXR 450LL12 495 94.8 94.6 0.72 0.66 45 4.3 23 6081 0.9 1.8 49.3 4680 75
355 HXR 500LJ12 495 95.1 94.9 0.71 0.65 50 4.5 27 6851 0.9 1.9 64.6 5890 75
400 HXR 500LK12 495 95.0 94.8 0.71 0.66 57 4.5 30 7720 0.9 1.9 68.6 6080 75
450 HXR 500LL12 495 95.1 95.0 0.72 0.66 63 4.5 33 8687 0.9 1.8 74.6 6380 75
500 HXR 500LN12 495 95.3 95.1 0.72 0.67 70 4.5 36 9651 0.9 1.8 82.6 6770 75
560 HXR 500LQ12 495 95.3 95.1 0.72 0.66 79 4.5 41 10806 0.9 1.8 90.5 7160 75
630 HXR 500LS12 495 95.4 95.2 0.71 0.66 89 4.6 47 12153 1.0 1.9 102.5 7740 75
710 HXR 560LM12 496 96.3 96.3 0.77 0.73 92 4.6 42 13669 0.7 1.9 137.5 9600 75
800 HXR 560LP12 496 96.4 96.3 0.76 0.70 106 5.1 54 15388 0.8 2.1 151.7 10060 75
900 HXR 560LS12 497 96.5 96.5 0.76 0.70 118 5.2 59 17308 0.8 2.2 180.2 11060 75
1000 HXR 560LU12 497 96.7 96.6 0.77 0.72 130 4.8 60 19215 0.8 1.9 209.8 12020 75

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

140 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized cast iron motors, HXR 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 10000 V 50 Hz


400 HXR 450LF2 2983 95.5 95.2 0.91 0.89 27 6.7 7 1281 0.6 2.6 11.5 3790 85
450 HXR 450LF2 2984 95.8 95.5 0.90 0.88 30 7.0 8 1440 0.7 2.7 11.9 3870 85
500 HXR 450LG2 2985 96.0 95.8 0.91 0.89 33 7.1 8 1600 0.6 2.8 12.5 4010 85
560 HXR 500LF2 2987 96.0 95.6 0.90 0.88 37 7.2 10 1790 0.6 2.9 20.7 5300 86
630 HXR 500LG2 2987 96.2 95.9 0.92 0.90 41 7.2 10 2014 0.6 2.8 22.8 5570 86
710 HXR 500LJ2 2988 96.5 96.2 0.91 0.89 47 7.3 11 2269 0.6 2.8 24.7 5850 86
800 HXR 500LL2 2988 96.7 96.5 0.92 0.91 52 7.2 11 2557 0.6 2.7 27.6 6300 86
900 HXR 500LM2 2989 96.8 96.6 0.90 0.89 59 7.5 15 2875 0.6 2.8 29.3 6490 86
1120 HXR 560LM2 2990 97.0 96.7 0.91 0.89 74 7.5 19 3577 0.6 2.9 46.0 9690 87
1250 HXR 560LQ2 2990 97.1 96.9 0.91 0.89 82 7.5 21 3992 0.6 2.8 52.5 10400 87

1500 r/min = 4 poles 10000 V 50 Hz


355 HXR 450LC4 1491 95.8 95.5 0.83 0.79 26 6.0 10 2273 0.8 2.3 11.8 3460 77
400 HXR 450LD4 1491 96.0 95.8 0.84 0.81 29 5.9 11 2561 0.8 2.2 12.9 3620 77
450 HXR 450LE4 1491 96.2 96.1 0.85 0.82 32 6.0 11 2882 0.8 2.2 14.0 3780 77
500 HXR 450LF4 1492 96.4 96.2 0.85 0.82 35 6.1 13 3201 0.8 2.2 15.0 3940 77
560 HXR 450LG4 1492 96.6 96.4 0.85 0.81 40 6.4 15 3584 0.9 2.3 16.1 4100 77
630 HXR 450LJ4 1493 96.7 96.5 0.83 0.79 45 6.6 18 4031 0.9 2.4 17.0 4270 77
710 HXR 500LF4 1491 96.6 96.5 0.86 0.83 50 5.7 16 4547 0.8 2.1 36.4 5460 77
800
900
HXR 500LG4
HXR 500LK4
1492
1493
96.8
97.0
96.8
97.0
0.87
0.87
0.85
0.85
55
61
6.2 17
6.5 19
5120
5758
0.8
0.8
2.2
2.3
39.3
46.8
5660
6240
77
77 5
1000 HXR 500LL4 1493 97.1 97.1 0.87 0.84 68 6.3 22 6397 0.8 2.2 49.0 6430 77
1120 HXR 560LL4 1494 97.4 97.3 0.87 0.85 76 6.6 25 7159 0.7 2.5 71.7 9530 82
1250 HXR 560LN4 1495 97.4 97.4 0.87 0.84 85 6.9 29 7985 0.7 2.6 78.9 9950 82
1400 HXR 560LR4 1495 97.6 97.5 0.87 0.84 95 7.0 33 8942 0.7 2.7 87.7 10560 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 141


HV Pressurized cast iron motors, HXR 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 10000 V 50 Hz


315 HXR 450LD6 993 95.5 95.2 0.79 0.73 24 5.1 11 3030 0.7 2.1 14.4 3680 76
355 HXR 450LE6 992 95.6 95.4 0.79 0.74 27 5.3 12 3419 0.8 2.3 15.9 3910 76
400 HXR 450LH6 994 95.9 95.7 0.77 0.71 31 5.7 15 3844 0.8 2.4 17.6 4160 76
450 HXR 450LJ6 993 96.1 95.9 0.79 0.74 34 5.4 16 4326 0.8 2.2 18.7 4310 76
500 HXR 450LK6 994 96.3 96.0 0.80 0.75 37 6.3 17 4801 0.9 2.4 28.9 4540 76
560 HXR 500LF6 995 96.4 96.3 0.82 0.77 41 6.3 18 5375 0.9 2.4 41.1 5420 77
630 HXR 500LG6 995 96.6 96.5 0.82 0.78 46 6.2 19 6048 0.8 2.3 44.0 5610 77
710 HXR 500LH6 995 96.7 96.6 0.83 0.79 51 6.1 21 6817 0.9 2.2 46.9 5800 77
800 HXR 500LL6 995 96.9 96.8 0.82 0.77 58 6.5 25 7676 0.9 2.4 54.0 6280 77
900 HXR 500LM6 995 97.0 96.9 0.81 0.76 66 6.3 29 8635 0.8 2.3 58.1 6560 77
1000 HXR 560LL6 996 97.2 97.1 0.84 0.79 71 6.3 28 9588 0.7 2.5 94.5 9480 81
1120 HXR 560LN6 996 97.3 97.2 0.84 0.79 79 6.5 32 10737 0.7 2.5 104.6 9960 81
1250 HXR 560LQ6 996 97.3 97.2 0.82 0.78 90 6.5 38 11980 0.7 2.6 113.8 10380 81
1400 HXR 560LR6 997 97.4 97.2 0.79 0.72 106 7.1 53 13410 0.8 2.8 118.0 10620 81

750 r/min = 8 poles 10000 V 50 Hz


315 HXR 500LD8 745 94.8 94.3 0.77 0.71 25 5.8 13 4038 0.9 2.4 35.5 4990 75
355 HXR 500LE8 745 94.9 94.6 0.79 0.73 28 5.7 13 4552 0.9 2.3 37.0 5090 75
400 HXR 500LF8 745 95.2 94.9 0.78 0.72 31 5.7 15 5128 0.9 2.3 39.9 5290 75

5 450
500
HXR 500LG8
HXR 500LH8
745
745
95.5
95.7
95.2
95.4
0.78
0.79
0.72
0.74
35
38
5.8 17
5.8 18
5767
6409
0.9
0.9
2.3
2.3
44.3
47.3
5580
5770
75
75
560 HXR 500LJ8 745 95.8 95.6 0.80 0.75 42 5.8 19 7180 0.9 2.3 50.3 5960 75
630 HXR 500LK8 745 96.0 95.8 0.80 0.75 47 5.7 21 8078 0.9 2.2 53.3 6160 75
710 HXR 500LM8 745 96.1 96.0 0.80 0.76 53 5.6 23 9105 0.9 2.2 57.7 6440 75
800 HXR 500LP8 744 96.2 96.2 0.81 0.77 59 5.5 25 10261 0.9 2.1 63.6 6830 75
900 HXR 560LM8 746 96.7 96.6 0.77 0.72 70 5.5 33 11518 0.8 2.2 97.9 9570 78
1000 HXR 560LN8 747 96.9 96.8 0.76 0.70 78 5.8 40 12789 0.8 2.3 106.0 9940 78
1120 HXR 560LR8 746 97.0 96.9 0.78 0.72 86 5.7 41 14332 0.8 2.2 120.8 10660 78

600 r/min = 10 poles 10000 V 50 Hz


560 HXR 560LL10 597 95.6 95.3 0.71 0.64 48 5.1 27 8959 0.8 2.1 95.7 9390 77
630 HXR 560LN10 596 95.7 95.5 0.72 0.65 53 5.3 29 10086 1.0 2.1 105.9 9870 77
710 HXR 560LR10 597 96.0 95.7 0.71 0.65 60 5.0 33 11359 0.8 2.1 118.6 10480 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

142 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


630 AMA 400L2A 2977 95.3 95.1 0.86 0.84 148 5.4 43 2021 0.6 2.3 7.1 3000 85
710 AMA 400L2A 2977 95.6 95.5 0.86 0.85 165 5.5 46 2277 0.6 2.3 7.5 3130 85
800 AMA 400L2A 2977 95.7 95.7 0.87 0.86 184 5.5 47 2566 0.6 2.3 8.0 3220 85
900 AMA 400L2A 2978 96.0 96.0 0.87 0.86 206 5.6 52 2886 0.6 2.3 8.5 3340 85
1000 AMA 400L2A 2979 96.2 96.2 0.87 0.85 230 5.8 61 3206 0.7 2.4 8.9 3450 85
1120 AMA 450L2A 2979 96.2 96.1 0.86 0.85 259 5.1 69 3590 0.5 2.2 11.6 4270 86
1250 AMA 450L2A 2980 96.4 96.3 0.85 0.83 295 5.1 84 4005 0.5 2.2 12.3 4420 86
1400 AMA 450L2A 2982 96.6 96.5 0.85 0.83 328 5.4 93 4484 0.5 2.3 13.8 4710 86
1600 AMA 500L2A 2983 96.5 96.5 0.89 0.89 357 5.0 80 5121 0.4 2.1 21.1 5370 87
1800 AMA 500L2A 2986 96.7 96.6 0.88 0.86 409 5.5 113 5757 0.5 2.3 22.4 5520 87
2000 AMA 500L2A 2983 96.8 96.8 0.90 0.89 443 5.0 94 6402 0.4 2.1 23.8 5710 87
2240 AMA 500L2A 2986 97.0 97.0 0.88 0.87 504 5.5 128 7164 0.5 2.2 26.3 6090 87

1500 r/min = 4 poles 3000 V 50 Hz


630 AMA 400L4A 1486 95.3 95.3 0.88 0.86 145 5.0 41 4049 0.6 2.0 15.6 3050 79
710 AMA 400L4A 1488 95.6 95.6 0.86 0.83 166 5.6 56 4558 0.7 2.3 16.6 3150 79
800 AMA 400L4A 1487 95.7 95.7 0.87 0.84 186 5.5 60 5136 0.7 2.2 17.6 3220 79
900 AMA 400L4A 1488 95.9 95.9 0.86 0.83 210 5.5 69 5778 0.7 2.2 18.5 3330 79
1000 AMA 400L4A 1488 96.1 96.1 0.87 0.84 231 5.8 75 6417 0.8 2.3 20.5 3520 79
1120
1250
AMA 400L4A
AMA 450L4A
1487
1488
96.1
96.0
96.2
96.0
0.87
0.87
0.85
0.85
257
288
5.4 75
5.5 85
7191
8023
0.7
0.7
2.2
2.1
21.3
31.5
3550
4210
79
81 5
1400 AMA 450L4A 1488 96.2 96.3 0.88 0.86 318 5.5 87 8984 0.7 2.1 35.0 4470 81
1600 AMA 450L4A 1488 96.4 96.5 0.88 0.86 364 5.6 102 10265 0.8 2.1 38.4 4720 81
1800 AMA 500L4A 1491 96.3 96.3 0.89 0.87 406 5.5 106 11531 0.7 2.0 55.9 5570 82
2000 AMA 500L4A 1491 96.5 96.5 0.88 0.87 453 5.5 121 12811 0.7 2.0 58.8 5730 82
2240 AMA 500L4A 1491 96.6 96.6 0.88 0.87 506 5.7 135 14344 0.7 2.1 64.6 6030 82
2500 AMA 500L4A 1490 96.7 96.8 0.89 0.89 556 5.5 125 16024 0.8 2.0 70.2 6380 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 143


HV Pressurized modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


450 AMA 400L6A 988 95.0 95.2 0.84 0.81 109 5.0 40 4350 0.8 2.0 17.0 2950 78
500 AMA 400L6A 989 95.2 95.3 0.81 0.77 124 5.0 51 4829 0.7 2.0 18.1 3050 78
560 AMA 400L6A 988 95.3 95.4 0.83 0.80 136 5.0 51 5411 0.8 1.9 19.4 3130 78
630 AMA 400L6A 990 95.5 95.6 0.82 0.78 155 5.2 62 6080 0.8 2.0 21.7 3320 78
710 AMA 400L6A 990 95.6 95.7 0.81 0.77 175 5.3 73 6851 0.8 2.0 22.9 3410 78
800 AMA 400L6A 990 95.8 95.9 0.83 0.79 193 5.4 74 7720 0.8 2.0 25.4 3600 78
900 AMA 450L6A 991 96.0 96.2 0.86 0.83 210 5.2 67 8670 0.6 2.0 39.8 4220 79
1000 AMA 450L6A 992 96.2 96.3 0.85 0.82 236 5.4 82 9629 0.7 2.0 42.0 4340 79
1120 AMA 450L6A 991 96.1 96.3 0.86 0.84 260 5.4 80 10792 0.7 2.1 44.4 4450 79
1250 AMA 450L6A 992 96.4 96.5 0.84 0.81 296 5.5 104 12033 0.7 2.1 48.6 4700 79
1400 AMA 500L6A 992 96.5 96.6 0.87 0.85 320 5.6 95 13474 0.7 2.1 68.5 5560 79
1600 AMA 500L6A 993 96.6 96.7 0.87 0.85 367 5.8 115 15393 0.8 2.2 75.6 5850 79
1800 AMA 500L6A 992 96.6 96.8 0.88 0.87 406 5.5 106 17328 0.7 2.0 83.0 6140 79
2000 AMA 500L6A 993 96.8 96.9 0.86 0.84 461 5.8 149 19225 0.7 2.2 91.0 6450 79

750 r/min = 8 poles 3000 V 50 Hz


280 AMA 400L8A 741 94.8 94.8 0.82 0.78 69 5.2 28 3611 0.9 2.1 19.1 2920 77
315 AMA 400L8A 740 94.7 94.9 0.84 0.81 76 4.9 28 4066 0.9 1.9 20.5 3000 77
355 AMA 400L8A 741 95.0 95.1 0.83 0.79 87 5.3 35 4576 1.0 2.1 21.9 3100 77

5 400
450
AMA 400L8A
AMA 400L8A
740
740
95.1
95.1
95.3
95.3
0.83
0.83
0.80
0.80
97
109
5.2 37
5.2 41
5158
5804
0.9
0.9
2.1
2.0
23.3
24.8
3200
3290
77
77
500 AMA 400L8A 741 95.3 95.4 0.83 0.79 121 5.3 47 6447 1.0 2.1 26.2 3380 77
560 AMA 400L8A 741 95.3 95.5 0.84 0.80 135 5.2 50 7221 1.0 2.0 29.0 3570 77
630 AMA 450L8A 743 95.7 95.8 0.81 0.77 155 5.5 66 8097 0.8 2.2 42.7 4050 77
710 AMA 450L8A 742 95.9 96.1 0.85 0.82 167 5.4 58 9136 0.8 2.0 48.3 4300 77
800 AMA 450L8A 742 96.0 96.2 0.85 0.83 188 5.4 63 10293 0.8 2.0 53.7 4540 77
900 AMA 450L8A 743 96.2 96.4 0.85 0.82 211 5.7 74 11572 0.9 2.2 59.1 4790 77
1000 AMA 500L8A 742 96.1 96.4 0.87 0.85 231 5.0 67 12870 0.7 2.0 79.5 5500 77
1120 AMA 500L8A 743 96.4 96.6 0.87 0.85 258 5.4 79 14394 0.7 2.1 89.0 5810 77
1250 AMA 500L8A 743 96.4 96.6 0.86 0.83 291 5.5 96 16065 0.8 2.1 96.7 6080 77
1400 AMA 500L8A 743 96.4 96.7 0.87 0.84 323 5.6 101 17997 0.8 2.1 105.9 6380 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

144 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


200 AMA 400L10A 592 93.6 93.6 0.73 0.67 56 4.5 30 3227 0.8 2.0 17.6 2820 76
224 AMA 400L10A 592 93.8 93.8 0.75 0.69 61 4.4 31 3615 0.7 1.9 19.1 2920 76
250 AMA 400L10A 592 94.0 94.0 0.75 0.70 68 4.4 33 4035 0.7 1.9 20.5 3020 76
280 AMA 400L10A 592 94.1 94.2 0.75 0.70 76 4.4 38 4517 0.8 1.9 21.9 3110 76
315 AMA 400L10A 593 94.3 94.2 0.74 0.67 87 4.8 46 5071 0.9 2.0 24.8 3290 76
355 AMA 400L10A 593 94.5 94.5 0.75 0.69 97 4.6 49 5718 0.9 1.9 26.3 3400 76
400 AMA 400L10A 593 94.7 94.5 0.73 0.67 111 4.9 59 6437 0.9 2.0 29.1 3590 76
450 AMA 450L10A 592 94.9 95.1 0.82 0.78 112 4.7 45 7254 0.8 1.9 42.7 4040 76
500 AMA 450L10A 593 95.1 95.2 0.81 0.77 125 4.9 52 8055 0.9 2.0 45.4 4160 76
560 AMA 450L10A 593 95.2 95.4 0.82 0.78 139 4.9 56 9021 0.9 2.0 50.8 4400 76
630 AMA 450L10A 593 95.4 95.5 0.82 0.79 154 4.9 60 10149 0.9 2.0 58.9 4770 76
710 AMA 500L10A 595 95.8 95.8 0.81 0.76 177 5.6 79 11397 0.8 2.2 80.2 5450 76
800 AMA 500L10A 595 95.9 95.9 0.82 0.77 197 5.3 82 12849 0.8 2.1 84.7 5600 76
900 AMA 500L10A 594 96.0 96.1 0.83 0.80 216 5.5 83 14457 0.8 2.1 98.4 6060 76
1000 AMA 500L10A 594 96.0 96.2 0.85 0.82 237 5.2 84 16073 0.8 2.0 107.4 6350 76

500 r/min = 12 poles 3000 V 50 Hz


140 AMA 400L12A 493 92.5 92.2 0.70 0.64 41 4.1 23 2711 0.8 1.9 19.2 2910 76
160 AMA 400L12A 493 92.7 92.5 0.72 0.66 46 4.0 25 3101 0.8 1.8 20.6 3010 76
180
200
AMA 400L12A
AMA 400L12A
493
493
92.9
93.1
92.7
92.8
0.72
0.71
0.66
0.65
52
58
4.0 27
4.0 31
3488
3874
0.8
0.8
1.8
1.9
22.1
23.5
3100
3200
76
76 5
224 AMA 400L12A 493 93.2 92.8 0.70 0.64 66 4.2 37 4335 0.9 2.0 24.9 3290 76
250 AMA 400L12A 493 93.1 92.9 0.71 0.65 72 4.1 39 4842 0.8 1.9 26.4 3370 76
280 AMA 400L12A 494 93.3 93.0 0.70 0.64 82 4.2 46 5418 0.9 2.0 29.2 3560 76
315 AMA 450L12A 495 94.5 94.3 0.72 0.65 90 4.7 51 6082 0.9 2.1 42.9 4020 76
355 AMA 450L12A 495 94.6 94.4 0.71 0.64 101 4.7 58 6855 0.9 2.1 45.6 4150 76
400 AMA 450L12A 494 94.7 94.6 0.73 0.67 111 4.6 60 7726 0.8 2.0 51.0 4380 76
450 AMA 450L12A 494 94.6 94.6 0.74 0.69 123 4.4 63 8698 0.8 1.9 53.7 4480 76
500 AMA 450L12A 494 94.8 94.7 0.74 0.68 137 4.6 72 9659 0.8 2.0 59.0 4720 76
560 AMA 500L12A 494 95.2 95.2 0.77 0.72 148 4.5 70 10816 0.7 1.9 79.9 5440 76
630 AMA 500L12A 495 95.3 95.3 0.77 0.72 166 4.5 78 12165 0.7 1.9 88.9 5750 76
710 AMA 500L12A 494 95.4 95.5 0.77 0.72 186 4.4 85 13715 0.7 1.8 93.3 5930 76
800 AMA 500L12A 495 95.5 95.5 0.77 0.72 209 4.6 98 15444 0.7 1.9 106.8 6350 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 145


HV Pressurized modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


630 AMA 400L2A 2979 95.0 94.9 0.88 0.86 73 5.7 20 2020 0.6 2.4 7.5 3050 85
710 AMA 400L2A 2977 95.3 95.3 0.87 0.85 83 5.5 23 2277 0.6 2.3 7.5 3070 85
800 AMA 400L2A 2977 95.6 95.6 0.88 0.86 92 5.5 24 2566 0.6 2.3 8.0 3190 85
900 AMA 400L2A 2978 95.8 95.8 0.87 0.86 103 5.5 26 2886 0.6 2.3 8.5 3300 85
1000 AMA 400L2A 2979 96.0 96.0 0.87 0.85 115 5.8 31 3206 0.7 2.4 8.9 3410 85
1120 AMA 450L2A 2979 96.1 96.0 0.86 0.85 130 5.1 35 3590 0.5 2.2 11.6 4220 86
1250 AMA 450L2A 2980 96.3 96.2 0.84 0.82 148 5.3 43 4005 0.5 2.2 12.3 4350 86
1400 AMA 450L2A 2982 96.5 96.4 0.85 0.83 164 5.4 46 4484 0.5 2.3 13.8 4650 86
1600 AMA 500L2A 2986 96.4 96.3 0.87 0.85 183 5.4 52 5118 0.4 2.2 21.0 5250 87
1800 AMA 500L2A 2986 96.6 96.6 0.88 0.86 204 5.5 56 5757 0.5 2.3 22.4 5460 87
2000 AMA 500L2A 2986 96.8 96.7 0.87 0.85 228 5.5 64 6396 0.5 2.3 23.7 5640 87
2240 AMA 500L2A 2986 96.9 96.9 0.88 0.87 252 5.5 64 7164 0.5 2.2 26.3 6010 87

1500 r/min = 4 poles 6000 V 50 Hz


630 AMA 400L4A 1487 94.9 95.0 0.89 0.87 72 5.1 20 4046 0.6 2.0 16.6 3060 79
710 AMA 400L4A 1487 95.3 95.4 0.86 0.83 84 5.5 29 4558 0.7 2.2 16.5 3080 79
800 AMA 400L4A 1487 95.5 95.6 0.86 0.84 93 5.4 31 5136 0.7 2.2 17.5 3180 79
900 AMA 400L4A 1487 95.7 95.8 0.86 0.83 105 5.5 34 5778 0.7 2.2 18.5 3280 79
1000 AMA 400L4A 1488 95.9 95.9 0.85 0.82 118 5.8 42 6417 0.8 2.3 19.5 3380 79

5 1250
1400
AMA 450L4A
AMA 450L4A
1488
1488
95.9
96.1
95.9
96.2
0.87
0.88
0.85
0.86
144 5.5 43
160 5.5 45
8023
8985
0.7
0.7
2.1
2.0
31.5
34.9
4150
4410
81
81
1600 AMA 500L4A 1491 96.0 96.0 0.88 0.87 181 5.5 49 10249 0.7 2.0 52.8 5310 82
1800 AMA 500L4A 1491 96.2 96.2 0.89 0.87 203 5.6 53 11531 0.7 2.0 55.8 5470 82
2000 AMA 500L4A 1491 96.3 96.4 0.88 0.86 227 5.5 62 12811 0.7 2.1 58.6 5630 82
2240 AMA 500L4A 1491 96.5 96.6 0.88 0.86 255 5.6 70 14344 0.7 2.1 64.2 5950 82
2500 AMA 500L4A 1490 96.6 96.7 0.88 0.86 284 5.6 75 16020 0.8 2.0 67.1 6130 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

146 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


450 AMA 400L6A 988 94.9 95.0 0.84 0.81 54 4.7 19 4351 0.7 1.9 15.2 3000 78
500 AMA 400L6A 989 94.9 95.0 0.82 0.78 62 5.1 26 4829 0.8 2.0 18.1 2980 78
560 AMA 400L6A 988 95.0 95.2 0.83 0.80 68 5.1 25 5410 0.8 2.0 19.4 3070 78
630 AMA 400L6A 990 95.3 95.4 0.82 0.78 77 5.3 31 6080 0.8 2.0 21.7 3260 78
710 AMA 400L6A 990 95.4 95.5 0.82 0.77 88 5.3 37 6851 0.8 2.0 22.9 3360 78
800 AMA 450L6A 991 95.7 95.9 0.86 0.84 93 5.3 30 7707 0.7 2.0 37.6 4030 79
900 AMA 450L6A 991 95.9 96.0 0.86 0.84 105 5.3 34 8670 0.7 2.0 39.8 4160 79
1000 AMA 450L6A 992 96.1 96.2 0.85 0.82 118 5.5 41 9629 0.7 2.1 42.0 4290 79
1125 AMA 450L6A 991 96.0 96.3 0.86 0.84 130 5.4 40 10840 0.7 2.1 44.4 4400 79
1250 AMA 450L6A 993 96.3 96.4 0.82 0.78 152 5.9 62 12024 0.8 2.3 48.6 4670 79
1400 AMA 500L6A 992 96.3 96.4 0.87 0.85 161 5.5 48 13475 0.7 2.0 68.3 5450 79
1600 AMA 500L6A 992 96.4 96.6 0.88 0.86 182 5.6 51 15400 0.8 2.0 75.6 5740 79
1800 AMA 500L6A 992 96.5 96.7 0.89 0.87 203 5.5 53 17328 0.8 2.0 83.0 6040 79
2000 AMA 500L6A 993 96.6 96.8 0.87 0.84 230 6.1 74 19224 0.8 2.3 91.6 6380 79

750 r/min = 8 poles 6000 V 50 Hz


280 AMA 400L8A 740 94.1 94.3 0.83 0.79 35 5.1 14 3611 0.9 2.1 19.1 2860 77
315 AMA 400L8A 740 94.2 94.5 0.84 0.81 38 4.8 14 4067 0.8 1.9 20.5 2960 77
355 AMA 400L8A 741 94.5 94.7 0.83 0.79 44 5.3 17 4577 0.9 2.1 21.9 3050 77
400
450
AMA 400L8A
AMA 400L8A
740
740
94.6
94.7
94.9
95.0
0.83
0.84
0.80
0.80
49
55
5.1
5.1
19
21
5159
5805
0.9
0.9
2.0
2.0
23.3
24.8
3140
3240
77
77 5
500 AMA 400L8A 741 94.9 95.1 0.83 0.80 61 5.2 24 6447 1.0 2.0 26.2 3330 77
560 AMA 450L8A 743 95.3 95.4 0.82 0.77 69 5.3 29 7198 0.8 2.1 40.0 3880 77
630 AMA 450L8A 743 95.4 95.6 0.81 0.77 78 5.4 33 8098 0.8 2.1 42.7 4000 77
710 AMA 450L8A 742 95.6 95.9 0.85 0.82 84 5.3 29 9136 0.8 2.1 48.3 4240 77
800 AMA 450L8A 742 95.8 96.0 0.86 0.83 94 5.4 32 10293 0.8 2.0 53.7 4480 77
900 AMA 500L8A 742 95.8 96.1 0.86 0.84 105 5.0 32 11585 0.7 2.0 70.6 5130 77
1000 AMA 500L8A 742 95.9 96.3 0.87 0.85 115 5.0 33 12870 0.7 2.0 79.5 5430 77
1120 AMA 500L8A 743 96.1 96.4 0.87 0.85 129 5.3 39 14395 0.7 2.1 89.0 5700 77
1250 AMA 500L8A 743 96.2 96.4 0.86 0.83 146 5.4 48 16062 0.8 2.0 96.7 5990 77
1400 AMA 500L8A 743 96.3 96.5 0.86 0.84 162 5.5 51 17994 0.8 2.1 105.9 6290 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 147


HV Pressurized modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


200 AMA 400L10A 592 93.2 93.0 0.70 0.63 30 4.0 17 3225 0.7 2.0 15.4 2970 76
224 AMA 400L10A 591 93.1 93.2 0.72 0.66 32 3.7 17 3618 0.6 1.7 15.4 2970 76
250 AMA 400L10A 593 93.6 93.4 0.72 0.65 36 4.6 20 4026 0.8 2.1 20.9 3150 76
280 AMA 400L10A 592 93.6 93.6 0.74 0.68 39 4.2 20 4516 0.7 1.9 20.9 3150 76
315 AMA 400L10A 593 93.9 93.8 0.74 0.68 44 4.7 23 5071 0.9 2.0 24.8 3240 76
355 AMA 400L10A 593 94.0 94.0 0.75 0.69 49 4.6 24 5719 0.8 1.9 26.3 3330 76
400 AMA 450L10A 592 94.4 94.7 0.82 0.78 50 4.7 20 6448 0.8 1.9 40.1 3850 76
450 AMA 450L10A 592 94.5 94.8 0.82 0.78 56 4.7 22 7254 0.8 1.9 42.7 3970 76
500 AMA 450L10A 593 94.7 94.9 0.81 0.77 62 4.9 26 8055 0.9 2.0 45.4 4090 76
560 AMA 450L10A 593 94.9 95.1 0.82 0.78 69 4.9 28 9021 0.9 2.0 50.8 4330 76
630 AMA 500L10A 595 95.5 95.5 0.82 0.77 78 5.5 33 10115 0.8 2.2 75.8 5230 76
710 AMA 500L10A 594 95.5 95.6 0.83 0.79 86 5.4 35 11405 0.8 2.2 80.4 5380 76
800 AMA 500L10A 594 95.7 95.9 0.83 0.79 97 5.3 37 12856 0.8 2.1 84.9 5560 76
900 AMA 500L10A 594 95.9 96.0 0.84 0.80 108 5.5 41 14457 0.8 2.1 98.4 6010 76
1000 AMA 500L10A 594 95.8 96.0 0.84 0.81 119 5.3 44 16067 0.8 2.1 107.4 6270 76

500 r/min = 12 poles 6000 V 50 Hz


140 AMA 400L12A 494 91.6 90.9 0.67 0.59 22 4.1 14 2708 0.9 2.1 19.6 3050 76
160 AMA 400L12A 493 91.7 91.4 0.70 0.63 24 3.8 14 3101 0.7 1.8 19.6 3050 76

5 180
200
AMA 400L12A
AMA 400L12A
493
492
92.0
92.1
91.6
91.9
0.69
0.70
0.63
0.65
27
30
3.8 16
3.7 16
3487
3879
0.8
0.7
1.8
1.7
20.9
22.1
3140
3240
76
76
224 AMA 400L12A 493 92.3 92.0 0.71 0.64 33 4.1 19 4336 0.8 1.9 24.9 3220 76
250 AMA 400L12A 493 92.4 92.3 0.72 0.66 36 4.0 20 4843 0.8 1.8 26.4 3320 76
280 AMA 450L12A 495 93.8 93.6 0.72 0.65 40 4.8 23 5406 0.9 2.2 40.2 3850 76
315 AMA 450L12A 495 94.0 93.8 0.72 0.65 45 4.8 25 6083 0.9 2.2 42.9 3970 76
355 AMA 450L12A 495 94.1 94.0 0.72 0.65 50 4.8 29 6855 0.9 2.1 45.6 4090 76
400 AMA 450L12A 494 94.3 94.2 0.74 0.67 55 4.7 30 7726 0.9 2.1 51.0 4320 76
450 AMA 450L12A 494 94.0 94.1 0.75 0.69 61 4.5 31 8699 0.8 1.9 53.7 4410 76
500 AMA 500L12A 495 94.9 94.9 0.76 0.70 67 4.7 34 9650 0.8 2.0 75.2 5250 76
560 AMA 500L12A 494 94.8 94.9 0.77 0.72 73 4.6 35 10816 0.8 1.9 79.9 5370 76
630 AMA 500L12A 495 95.0 95.0 0.78 0.72 82 4.7 39 12164 0.8 2.0 88.9 5670 76
710 AMA 500L12A 494 95.2 95.3 0.78 0.73 92 4.6 42 13715 0.8 1.9 93.3 5850 76
800 AMA 500L12A 495 95.3 95.4 0.78 0.72 104 4.8 49 15444 0.8 2.0 106.8 6290 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

148 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized modular motors 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 10000 V 50 Hz


560 AMA 450L2A 2980 94.1 93.7 0.87 0.84 40 5.9 13 1794 0.6 2.6 10.5 3820 86
630 AMA 450L2A 2983 94.6 94.2 0.87 0.83 44 6.4 15 2017 0.6 2.8 11.2 3970 86
710 AMA 450L2A 2982 94.9 94.6 0.88 0.85 49 6.2 15 2274 0.6 2.7 11.9 4110 86
800 AMA 450L2A 2982 95.1 94.9 0.87 0.84 56 6.3 18 2562 0.6 2.7 11.9 4120 86
900 AMA 450L2A 2981 95.4 95.3 0.88 0.86 62 5.7 16 2883 0.6 2.4 12.7 4270 86
1000 AMA 500L2A 2985 95.4 95.1 0.87 0.85 69 5.5 20 3199 0.5 2.3 18.7 4810 87
1120 AMA 500L2A 2985 95.7 95.4 0.88 0.86 77 5.5 21 3583 0.5 2.3 20.0 5000 87
1250 AMA 500L2A 2985 95.9 95.7 0.88 0.87 85 5.5 22 3999 0.5 2.2 21.4 5190 87
1400 AMA 500L2A 2986 96.1 96.0 0.88 0.87 95 5.5 24 4477 0.5 2.2 22.7 5370 87
1600 AMA 500L2A 2985 96.3 96.2 0.88 0.86 109 5.5 28 5118 0.5 2.2 24.1 5560 87

1500 r/min = 4 poles 10000 V 50 Hz


630 AMA 450L4A 1490 94.7 94.3 0.87 0.84 44 6.5 16 4038 0.7 2.7 26.3 4050 81
710 AMA 450L4A 1489 94.8 94.6 0.88 0.85 49 5.8 16 4555 0.6 2.4 26.3 4050 81
800 AMA 450L4A 1488 95.1 94.9 0.89 0.87 54 5.9 16 5134 0.7 2.4 27.8 4180 81
900 AMA 450L4A 1488 95.2 95.1 0.88 0.86 62 6.0 19 5776 0.7 2.5 27.3 4180 81
1000 AMA 500L4A 1491 94.5 94.4 0.86 0.83 71 5.3 24 6405 0.6 2.0 43.4 4760 82
1120 AMA 500L4A 1491 94.8 94.7 0.87 0.85 78 5.3 23 7175 0.6 2.0 46.4 4910 82
1250 AMA 500L4A 1491 95.3 95.2 0.88 0.86 86 5.5 25 8007 0.7 2.0 49.1 5080 82
1400
1600
AMA 500L4A
AMA 500L4A
1491
1491
95.7
95.9
95.6
95.9
0.90
0.90
0.89
0.89
94 5.6 22
107 5.7 26
8965 0.6
10246 0.7
2.0
2.0
55.7
58.9
5400
5570
82
82 5
1800 AMA 500L4A 1490 95.9 96.0 0.88 0.86 124 5.5 35 11536 0.6 2.1 57.9 5560 82
2000 AMA 500L4A 1491 96.1 96.1 0.85 0.82 141 5.8 47 12811 0.7 2.3 60.6 5720 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 149


HV Pressurized modular motors 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 10000 V 50 Hz


450 AMA 450L6A 992 95.0 94.5 0.81 0.76 34 6.5 15 4331 1.0 2.7 30.6 4070 79
500 AMA 450L6A 991 95.0 94.8 0.83 0.78 37 5.9 15 4816 0.9 2.4 30.6 4070 79
560 AMA 450L6A 990 95.1 95.0 0.84 0.80 41 5.4 15 5401 0.8 2.2 30.6 4070 79
630 AMA 450L6A 989 95.0 95.1 0.85 0.82 45 5.0 15 6084 0.8 2.0 30.8 4070 79
710 AMA 450L6A 989 95.3 95.3 0.84 0.81 51 5.3 18 6852 0.8 2.1 32.3 4200 79
800 AMA 450L6A 989 95.4 95.5 0.85 0.83 57 4.9 19 7721 0.7 1.9 32.6 4200 79
900 AMA 500L6A 994 95.6 95.7 0.87 0.84 63 5.6 21 8649 0.6 2.1 64.0 5210 79
1000 AMA 500L6A 994 95.8 95.8 0.86 0.84 70 5.6 23 9609 0.6 2.1 67.5 5350 79
1120 AMA 500L6A 994 95.9 96.0 0.86 0.82 79 5.6 28 10760 0.6 2.1 70.9 5500 79
1250 AMA 500L6A 994 96.1 96.1 0.85 0.82 88 5.6 31 12009 0.6 2.1 74.6 5660 79
1400 AMA 500L6A 993 96.1 96.2 0.88 0.85 96 6.0 30 13460 0.8 2.2 75.8 5670 79

750 r/min = 8 poles 10000 V 50 Hz


630 AMA 500L8A 744 95.3 95.3 0.83 0.78 46 6.0 19 8082 1.0 2.1 74.4 5180 77
710 AMA 500L8A 746 95.7 95.6 0.82 0.77 52 5.7 22 9094 0.7 2.2 79.3 5330 77
800 AMA 500L8A 745 95.8 95.8 0.82 0.78 59 5.7 25 10248 0.7 2.2 83.7 5480 77
900 AMA 500L8A 745 95.9 95.9 0.82 0.77 66 5.7 28 11529 0.7 2.2 88.1 5620 77
1000 AMA 500L8A 745 96.0 96.1 0.83 0.78 73 5.7 30 12810 0.7 2.2 96.9 5920 77
1120 AMA 500L8A 745 96.0 96.1 0.84 0.81 80 5.6 30 14359 0.8 2.0 97.6 5920 77

5 600 r/min = 10 poles


450 AMA 500L10A 595 94.4 94.4
10000 V 50 Hz
0.81 0.75 34 5.8 16 7223 0.9 2.4 70.6 5000 76
500 AMA 500L10A 595 94.6 94.6 0.82 0.77 37 5.9 17 8028 0.9 2.4 75.3 5150 76
560 AMA 500L10A 595 94.8 94.9 0.82 0.77 42 5.9 19 8983 0.9 2.4 80.5 5300 76
630 AMA 500L10A 595 95.0 95.0 0.82 0.77 47 5.9 21 10107 0.9 2.4 85.0 5450 76
710 AMA 500L10A 595 95.1 95.1 0.82 0.77 53 5.9 24 11391 0.9 2.4 89.5 5600 76

500 r/min = 12 poles 10000 V 50 Hz


315 AMA 500L12A 495 93.3 93.2 0.74 0.67 26 4.5 15 6077 0.6 2.2 57.7 4860 76
355 AMA 500L12A 495 93.6 93.4 0.73 0.66 30 4.6 17 6847 0.7 2.2 61.4 5010 76
400 AMA 500L12A 495 94.0 93.8 0.74 0.67 33 4.7 18 7714 0.7 2.2 68.8 5300 76
450 AMA 500L12A 495 94.0 93.9 0.76 0.70 36 5.3 19 8678 0.8 2.3 84.2 5430 76
500 AMA 500L12A 495 94.2 94.1 0.76 0.70 40 5.2 21 9644 0.8 2.3 88.7 5570 76
560 AMA 500L12A 495 94.3 94.2 0.76 0.70 45 5.2 24 10802 0.8 2.3 93.1 5720 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

150 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


710 AMA 400L2L 2973 95.9 96.1 0.86 0.84 165 5.1 45 2280 0.6 2.2 6.1 2880 82
800 AMA 400L2L 2974 96.1 96.3 0.88 0.86 183 5.1 45 2568 0.6 2.2 6.5 2980 82
900 AMA 400L2L 2974 96.2 96.4 0.88 0.87 204 5.2 47 2890 0.6 2.1 7.0 3070 82
1000 AMA 400L2L 2977 96.4 96.6 0.89 0.87 225 5.4 53 3208 0.6 2.2 7.3 3190 82
1120 AMA 400L2L 2976 96.5 96.7 0.88 0.87 253 5.6 60 3593 0.7 2.3 7.9 3310 82
1250 AMA 450L2L 2977 96.6 96.7 0.88 0.86 283 4.9 69 4010 0.5 2.1 12.1 4080 83
1400 AMA 450L2L 2978 96.7 96.9 0.86 0.85 323 4.9 84 4489 0.5 2.1 12.8 4220 83
1600 AMA 450L2L 2979 96.9 97.1 0.87 0.86 367 5.1 92 5129 0.5 2.1 14.3 4520 83
1800 AMA 500L2L 2986 97.0 97.0 0.85 0.82 421 5.5 141 5756 0.5 2.3 19.7 5110 84
2000 AMA 500L2L 2984 97.0 97.1 0.89 0.87 447 5.2 112 6400 0.5 2.2 21.1 5300 84
2240 AMA 500L2L 2987 97.3 97.2 0.84 0.81 526 5.8 183 7162 0.5 2.4 22.4 5500 84
2500 AMA 500L2L 2984 97.3 97.4 0.89 0.88 553 5.3 126 8000 0.5 2.2 25.1 5880 84

1500 r/min = 4 poles 3000 V 50 Hz


710 AMA 400L4L 1488 95.8 95.9 0.80 0.75 178 5.4 80 4556 0.7 2.3 14.0 2850 79
800 AMA 400L4L 1488 96.0 96.1 0.81 0.77 197 5.4 82 5134 0.7 2.3 15.0 2960 79
900 AMA 400L4L 1488 96.2 96.3 0.82 0.77 221 5.5 91 5775 0.7 2.3 16.0 3070 79
1000 AMA 400L4L 1487 96.2 96.4 0.85 0.83 234 5.2 78 6423 0.7 2.1 17.0 3160 79
1120 AMA 400L4L 1487 96.3 96.5 0.84 0.81 265 5.4 94 7192 0.7 2.2 18.0 3260 79
1250
1400
AMA 400L4L
AMA 450L4L
1487
1486
96.4
96.2
96.6
96.5
0.83
0.87
0.80
0.86
298 5.5
321 4.9
109
85
8025
8996
0.7
0.7
2.2
1.9
19.0
29.4
3370
4000
79
80 5
1600 AMA 450L4L 1486 96.4 96.7 0.88 0.88 361 5.0 86 10281 0.7 1.9 33.0 4260 80
1800 AMA 450L4L 1487 96.6 96.9 0.89 0.88 404 5.4 99 11559 0.8 2.0 36.5 4520 80
2000 AMA 500L4L 1490 96.6 96.8 0.89 0.88 450 5.0 106 12822 0.6 1.8 53.5 5330 81
2240 AMA 500L4L 1490 96.7 96.9 0.88 0.88 505 5.0 121 14360 0.6 1.8 56.4 5490 81
2500 AMA 500L4L 1490 96.8 97.0 0.89 0.88 559 5.3 133 16020 0.7 1.9 62.6 5790 81
2800 AMA 500L4L 1490 97.0 97.2 0.89 0.89 621 5.5 142 17940 0.7 2.0 68.6 6140 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 151


HV Pressurized modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


500 AMA 400L6L 986 95.1 95.5 0.84 0.82 120 4.5 40 4841 0.7 1.8 15.5 2780 77
560 AMA 400L6L 987 95.4 95.6 0.84 0.80 135 4.9 49 5416 0.8 2.0 16.7 2880 77
630 AMA 400L6L 987 95.3 95.7 0.85 0.82 150 4.7 50 6096 0.7 1.9 18.0 2960 77
710 AMA 400L6L 988 95.6 95.9 0.85 0.82 169 5.2 59 6861 0.8 2.1 20.4 3150 77
800 AMA 400L6L 988 95.7 96.0 0.84 0.81 192 5.3 69 7729 0.9 2.1 21.6 3250 77
900 AMA 400L6L 988 95.8 96.1 0.85 0.82 213 5.2 71 8697 0.9 2.0 24.0 3440 77
1000 AMA 450L6L 992 96.3 96.4 0.81 0.77 245 5.4 101 9626 0.7 2.1 37.4 4020 78
1120 AMA 450L6L 991 96.3 96.6 0.86 0.84 260 5.2 81 10796 0.7 2.0 40.0 4140 78
1250 AMA 450L6L 990 96.2 96.6 0.87 0.85 289 4.9 80 12059 0.7 1.9 42.3 4250 78
1400 AMA 450L6L 990 96.3 96.7 0.87 0.86 322 5.0 89 13502 0.7 2.0 46.8 4490 78
1600 AMA 500L6L 991 96.5 96.8 0.88 0.87 362 5.2 94 15418 0.7 1.9 65.5 5300 79
1800 AMA 500L6L 992 96.6 96.9 0.88 0.86 408 5.6 113 17334 0.8 2.1 72.8 5570 79
2000 AMA 500L6L 991 96.7 97.0 0.89 0.88 446 5.4 105 19271 0.8 2.0 80.2 5890 79
2250 AMA 500L6L 991 96.8 97.1 0.89 0.88 502 5.5 121 21673 0.8 2.0 87.6 6190 79

750 r/min = 8 poles 3000 V 50 Hz


315 AMA 400L8L 738 94.5 94.9 0.83 0.81 77 4.6 27 4075 0.9 1.8 17.5 2730 75
355 AMA 400L8L 739 94.7 95.0 0.83 0.80 86 4.7 31 4585 0.8 1.9 19.0 2830 75
400 AMA 400L8L 739 94.9 95.3 0.84 0.81 97 4.8 35 5166 0.9 1.9 20.4 2930 75

5 450
500
AMA 400L8L
AMA 400L8L
739
739
95.1
95.1
95.4
95.5
0.84
0.84
0.81
0.82
108
120
4.7 37
4.7 41
5814
6460
0.8
0.9
1.8
1.8
21.8
23.3
3040
3120
75
75
560 AMA 400L8L 739 95.2 95.5 0.84 0.81 135 4.8 47 7233 0.9 1.8 24.7 3220 75
630 AMA 400L8L 739 95.2 95.6 0.84 0.82 151 4.7 50 8139 0.9 1.8 27.5 3400 75
710 AMA 450L8L 742 95.8 96.0 0.83 0.80 171 5.3 66 9137 0.8 2.1 40.7 3850 76
800 AMA 450L8L 741 95.8 96.2 0.86 0.84 188 4.8 58 10310 0.7 1.8 46.1 4090 76
900 AMA 450L8L 741 95.8 96.3 0.86 0.84 210 4.8 63 11597 0.7 1.8 51.5 4310 76
1000 AMA 450L8L 743 96.2 96.4 0.83 0.80 240 5.7 93 12854 0.9 2.2 56.7 4550 76
1120 AMA 500L8L 739 95.9 96.4 0.87 0.86 258 4.5 66 14463 0.7 1.8 75.5 5240 77
1250 AMA 500L8L 741 96.2 96.6 0.87 0.86 287 4.7 76 16105 0.7 1.8 84.9 5550 77
1400 AMA 500L8L 742 96.4 96.7 0.87 0.85 323 5.2 96 18015 0.8 2.0 93.7 5830 77
1600 AMA 500L8L 742 96.4 96.7 0.87 0.86 367 5.0 101 20601 0.8 1.9 102.6 6130 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

152 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


224 AMA 400L10L 591 93.6 93.8 0.75 0.70 61 4.2 30 3621 0.7 1.8 16.2 2660 75
250 AMA 400L10L 591 93.8 94.1 0.77 0.72 67 4.1 31 4042 0.7 1.8 17.6 2750 75
280 AMA 400L10L 591 93.9 94.2 0.77 0.73 74 4.1 33 4528 0.7 1.7 19.0 2850 75
315 AMA 400L10L 591 94.1 94.4 0.77 0.72 84 4.1 38 5092 0.7 1.8 20.5 2940 75
355 AMA 400L10L 592 94.3 94.4 0.76 0.71 96 4.5 46 5724 0.8 1.8 23.4 3120 75
400 AMA 400L10L 592 94.5 94.7 0.76 0.72 107 4.3 49 6454 0.8 1.7 24.8 3240 75
450 AMA 400L10L 592 94.7 94.8 0.75 0.70 121 4.6 59 7253 0.9 1.8 27.7 3420 75
500 AMA 450L10L 591 94.8 95.3 0.82 0.79 123 4.3 45 8073 0.7 1.7 40.5 3840 76
560 AMA 450L10L 592 95.0 95.4 0.82 0.79 138 4.4 52 9037 0.8 1.8 43.2 3960 76
630 AMA 450L10L 592 95.1 95.5 0.83 0.80 154 4.4 56 10167 0.8 1.8 48.6 4200 76
710 AMA 450L10L 592 95.2 95.6 0.83 0.81 172 4.4 60 11458 0.8 1.8 56.7 4560 76
800 AMA 500L10L 594 95.8 96.0 0.82 0.78 196 5.1 79 12857 0.7 2.0 76.8 5200 77
900 AMA 500L10L 593 95.9 96.2 0.84 0.81 215 4.8 75 14483 0.7 1.9 81.5 5390 77
1000 AMA 500L10L 594 96.0 96.2 0.84 0.81 238 5.0 83 16082 0.7 1.9 95.0 5810 77
1120 AMA 500L10L 594 96.1 96.3 0.83 0.79 270 5.2 104 17996 0.8 2.0 103.7 6100 77

500 r/min = 12 poles 3000 V 50 Hz


160 AMA 400L12L 491 92.4 92.5 0.73 0.68 45 3.7 23 3111 0.8 1.6 17.6 2740 75
180 AMA 400L12L 492 92.7 92.8 0.74 0.69 51 3.8 25 3496 0.7 1.7 19.2 2840 75
200
224
AMA 400L12L
AMA 400L12L
492
492
92.9
93.1
93.0
93.1
0.74
0.73
0.69
0.68
56
63
3.8 27
3.8 31
3883
4347
0.8
0.8
1.7
1.7
20.6
22.1
2940
3030
75
75 5
250 AMA 400L12L 493 93.3 93.1 0.72 0.67 71 4.0 37 4847 0.8 1.8 23.5 3130 75
280 AMA 400L12L 492 93.1 93.2 0.73 0.68 79 3.8 39 5434 0.8 1.7 24.9 3200 75
315 AMA 400L12L 493 93.4 93.3 0.73 0.67 89 4.0 46 6107 0.8 1.8 27.8 3400 75
355 AMA 450L12L 494 94.5 94.6 0.74 0.68 98 4.3 51 6866 0.8 1.9 40.7 3820 76
400 AMA 450L12L 494 94.6 94.7 0.74 0.68 111 4.3 58 7736 0.8 1.9 43.4 3940 76
450 AMA 450L12L 494 94.7 94.8 0.75 0.70 122 4.2 60 8706 0.7 1.8 48.8 4180 76
500 AMA 450L12L 493 94.6 94.8 0.76 0.71 134 4.0 63 9680 0.7 1.7 51.5 4270 76
560 AMA 450L12L 493 94.7 94.9 0.75 0.70 151 4.2 72 10836 0.7 1.8 56.8 4520 76
630 AMA 500L12L 493 95.0 95.3 0.78 0.74 163 4.1 70 12197 0.6 1.7 76.4 5190 77
710 AMA 500L12L 493 95.2 95.4 0.78 0.74 183 4.2 79 13742 0.6 1.7 85.3 5500 77
800 AMA 500L12L 493 95.3 95.6 0.79 0.75 206 4.0 86 15492 0.6 1.7 89.7 5680 77
900 AMA 500L12L 494 95.4 95.6 0.78 0.74 231 4.2 99 17415 0.6 1.7 103.1 6100 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 153


HV Pressurized modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


710 AMA 400L2L 2973 95.6 95.8 0.86 0.84 83 5.0 23 2280 0.6 2.1 6.1 2820 82
800 AMA 400L2L 2974 95.8 96.1 0.88 0.86 92 5.1 23 2569 0.6 2.1 6.5 2920 82
900 AMA 400L2L 2974 96.0 96.3 0.88 0.88 102 5.2 24 2890 0.6 2.1 7.0 3030 82
1000 AMA 400L2L 2977 96.2 96.5 0.89 0.87 113 5.4 27 3208 0.6 2.2 7.3 3140 82
1120 AMA 400L2L 2976 96.4 96.6 0.88 0.87 127 5.6 30 3594 0.7 2.3 7.9 3260 82
1250 AMA 450L2L 2977 96.5 96.6 0.88 0.87 142 5.0 34 4010 0.5 2.1 12.1 4020 83
1400 AMA 450L2L 2978 96.6 96.8 0.86 0.85 162 5.0 42 4489 0.5 2.1 12.8 4170 83
1600 AMA 450L2L 2979 96.8 97.0 0.87 0.86 183 5.1 46 5129 0.5 2.1 14.3 4460 83
1800 AMA 500L2L 2984 96.8 96.9 0.88 0.87 202 5.2 52 5761 0.4 2.2 19.8 5030 84
2000 AMA 500L2L 2984 97.0 97.1 0.89 0.87 224 5.3 56 6400 0.5 2.2 21.1 5230 84
2240 AMA 500L2L 2984 97.1 97.2 0.89 0.87 250 5.4 63 7168 0.5 2.2 22.4 5420 84
2500 AMA 500L2L 2984 97.2 97.3 0.89 0.88 277 5.4 63 8000 0.5 2.2 25.1 5790 84

1500 r/min = 4 poles 6000 V 50 Hz


710 AMA 400L4L 1487 95.6 95.8 0.86 0.84 83 5.4 27 4558 0.7 2.2 15.1 2900 79
800 AMA 400L4L 1486 95.7 96.0 0.87 0.85 92 5.1 28 5142 0.6 2.0 15.1 2910 79
900 AMA 400L4L 1486 95.8 96.2 0.87 0.85 103 5.1 30 5785 0.7 2.0 16.1 3010 79
1000 AMA 400L4L 1484 95.7 96.2 0.89 0.89 112 4.8 26 6435 0.6 1.9 17.2 3100 79
1120 AMA 400L4L 1484 95.8 96.3 0.89 0.88 126 4.9 30 7206 0.7 1.9 18.2 3200 79

5 1250
1400
AMA 450L4L
AMA 450L4L
1487
1486
95.9
96.1
96.2
96.4
0.86
0.87
0.84
0.86
145 5.0 43
160 5.0 42
8029
8996
0.6
0.7
2.0
1.9
27.7
29.4
3810
3940
80
80
1600 AMA 450L4L 1486 96.3 96.6 0.89 0.88 180 5.1 43 10281 0.7 1.9 33.0 4210 80
1800 AMA 500L4L 1489 96.3 96.5 0.89 0.88 203 5.0 49 11540 0.6 1.8 50.5 5070 81
2000 AMA 500L4L 1490 96.4 96.6 0.89 0.88 225 5.1 53 12822 0.6 1.9 53.5 5230 81
2240 AMA 500L4L 1490 96.5 96.8 0.89 0.88 252 5.1 60 14359 0.7 1.9 56.4 5390 81
2500 AMA 500L4L 1490 96.7 97.0 0.89 0.88 281 5.3 68 16021 0.7 2.0 62.2 5710 81
2800 AMA 500L4L 1490 96.9 97.1 0.89 0.88 312 5.5 73 17941 0.7 2.0 68.3 6020 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

154 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


500 AMA 400L6L 986 94.9 95.4 0.84 0.82 60 4.3 19 4842 0.6 1.7 13.7 2830 77
560 AMA 400L6L 987 95.0 95.4 0.84 0.81 68 5.0 25 5416 0.8 2.0 16.7 2810 77
630 AMA 400L6L 987 95.1 95.5 0.85 0.82 75 4.9 25 6096 0.8 1.9 18.0 2910 77
710 AMA 400L6L 988 95.4 95.7 0.85 0.82 85 5.3 30 6861 0.9 2.1 20.4 3100 77
800 AMA 400L6L 988 95.5 95.8 0.84 0.81 96 5.4 35 7730 0.9 2.1 21.6 3190 77
900 AMA 450L6L 991 95.8 96.1 0.86 0.83 106 5.3 35 8674 0.7 2.1 35.5 3830 78
1000 AMA 450L6L 990 96.0 96.4 0.87 0.85 115 5.1 34 9643 0.7 1.9 37.8 3950 78
1120 AMA 450L6L 991 96.2 96.5 0.86 0.84 130 5.3 40 10796 0.7 2.0 40.0 4080 78
1250 AMA 450L6L 990 96.1 96.5 0.87 0.85 144 5.0 40 12059 0.7 1.9 42.3 4190 78
1400 AMA 450L6L 990 96.2 96.6 0.87 0.86 161 5.1 44 13502 0.7 2.0 46.8 4430 78
1600 AMA 500L6L 991 96.3 96.7 0.88 0.87 181 5.3 47 15418 0.8 2.0 65.5 5210 79
1800 AMA 500L6L 991 96.4 96.8 0.89 0.88 203 5.3 51 17344 0.8 2.0 72.8 5500 79
2000 AMA 500L6L 991 96.5 96.9 0.89 0.88 224 5.3 53 19272 0.8 2.0 80.1 5800 79
2250 AMA 500L6L 991 96.6 97.0 0.89 0.89 251 5.4 59 21678 0.8 2.0 87.4 6090 79

750 r/min = 8 poles 6000 V 50 Hz


315 AMA 400L8L 739 94.0 94.5 0.84 0.81 39 4.6 14 4070 0.8 1.8 17.6 2690 75
355 AMA 400L8L 739 94.0 94.5 0.84 0.81 43 4.6 16 4586 0.8 1.8 19.0 2790 75
400 AMA 400L8L 739 94.5 94.9 0.84 0.81 49 4.7 17 5166 0.8 1.8 20.4 2880 75
450
500
AMA 400L8L
AMA 400L8L
739
739
94.5
94.6
95.0
95.1
0.84
0.84
0.82
0.82
54
60
4.6 19
4.6 21
5815
6461
0.8
0.8
1.8
1.8
21.8
23.3
2980
3070
75
75 5
560 AMA 400L8L 739 94.8 95.2 0.84 0.81 68 4.7 24 7234 0.9 1.8 24.7 3160 75
630 AMA 450L8L 742 95.3 95.7 0.83 0.80 76 5.2 29 8109 0.8 2.1 38.0 3670 76
710 AMA 450L8L 742 95.4 95.8 0.83 0.80 86 5.3 33 9138 0.8 2.1 40.7 3800 76
800 AMA 450L8L 741 95.5 96.0 0.86 0.84 94 4.7 29 10311 0.7 1.8 46.1 4030 76
900 AMA 450L8L 741 95.7 96.1 0.86 0.84 105 4.8 32 11598 0.7 1.8 51.5 4270 76
1000 AMA 500L8L 739 95.5 96.1 0.87 0.86 116 4.5 32 12914 0.7 1.8 66.7 4870 77
1120 AMA 500L8L 739 95.6 96.2 0.87 0.86 129 4.5 33 14464 0.7 1.8 75.5 5170 77
1250 AMA 500L8L 741 95.9 96.4 0.87 0.86 144 4.7 38 16101 0.7 1.8 85.0 5440 77
1400 AMA 500L8L 742 96.2 96.5 0.87 0.85 161 5.2 48 18011 0.8 2.0 93.9 5750 77
1600 AMA 500L8L 742 96.2 96.6 0.87 0.86 184 5.0 51 20596 0.7 1.9 102.8 6040 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 155


HV Pressurized modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


224 AMA 400L10L 591 93.2 93.3 0.72 0.66 32 3.7 17 3618 0.6 1.7 13.9 2800 75
250 AMA 400L10L 591 93.4 93.5 0.72 0.66 36 3.7 19 4037 0.6 1.8 14.8 2900 75
280 AMA 400L10L 592 93.4 93.6 0.74 0.68 39 4.1 20 4520 0.7 1.8 18.1 2890 75
315 AMA 400L10L 591 93.7 93.9 0.75 0.70 43 4.0 21 5086 0.6 1.8 20.6 3080 75
355 AMA 400L10L 592 93.8 94.0 0.76 0.71 48 4.4 23 5725 0.8 1.8 23.4 3070 75
400 AMA 400L10L 592 93.9 94.2 0.77 0.72 53 4.3 24 6455 0.8 1.7 24.8 3170 75
450 AMA 450L10L 591 94.2 94.8 0.83 0.80 56 4.2 20 7268 0.7 1.7 37.9 3650 76
500 AMA 450L10L 591 94.4 94.9 0.83 0.80 62 4.3 22 8074 0.7 1.7 40.5 3770 76
560 AMA 450L10L 592 94.6 95.0 0.82 0.79 69 4.4 26 9038 0.8 1.8 43.2 3890 76
630 AMA 450L10L 592 94.7 95.2 0.83 0.80 77 4.4 28 10167 0.8 1.8 48.6 4120 76
710 AMA 500L10L 594 95.4 95.7 0.83 0.79 86 5.0 33 11414 0.7 2.0 72.4 4980 77
800 AMA 500L10L 594 95.5 95.8 0.84 0.81 96 4.9 35 12869 0.7 1.9 77.0 5130 77
900 AMA 500L10L 593 95.6 96.0 0.84 0.81 108 4.7 37 14484 0.7 1.9 81.5 5320 77
1000 AMA 500L10L 594 95.8 96.1 0.84 0.81 119 4.9 41 16082 0.7 1.9 95.0 5760 77
1120 AMA 500L10L 594 95.7 96.1 0.85 0.82 133 4.8 44 18019 0.7 1.8 104.0 6020 77

500 r/min = 12 poles 6000 V 50 Hz


160 AMA 400L12L 493 91.8 91.5 0.69 0.63 24 3.8 14 3101 0.7 1.8 18.1 2880 75
180 AMA 400L12L 493 91.9 91.6 0.69 0.63 27 3.7 16 3490 0.7 1.7 18.1 2880 75

5 200
224
AMA 400L12L
AMA 400L12L
493
492
92.1
92.2
91.7
92.0
0.68
0.70
0.61
0.63
31
34
3.8 18
3.7 19
3875
4344
0.8
0.7
1.8
1.7
19.4
20.6
2980
3070
75
75
250 AMA 400L12L 492 92.3 92.3 0.73 0.67 36 3.9 19 4848 0.8 1.8 23.5 3060 75
280 AMA 400L12L 492 92.4 92.5 0.74 0.69 40 3.7 20 5435 0.7 1.6 24.9 3150 75
315 AMA 450L12L 494 93.9 93.9 0.74 0.68 44 4.4 23 6091 0.8 1.9 38.0 3640 76
355 AMA 450L12L 494 94.0 94.1 0.75 0.69 49 4.4 25 6866 0.8 1.9 40.7 3760 76
400 AMA 450L12L 494 94.1 94.2 0.74 0.68 55 4.4 29 7736 0.8 1.9 43.4 3880 76
450 AMA 450L12L 494 94.3 94.4 0.76 0.70 61 4.3 30 8706 0.8 1.8 48.8 4120 76
500 AMA 450L12L 493 93.9 94.3 0.77 0.72 67 4.1 31 9681 0.7 1.7 51.5 4200 76
560 AMA 500L12L 494 94.6 94.8 0.78 0.73 73 4.4 34 10831 0.7 1.9 71.8 4960 77
630 AMA 500L12L 493 94.6 95.0 0.79 0.75 81 4.2 35 12197 0.7 1.8 76.4 5110 77
710 AMA 500L12L 493 94.8 95.1 0.79 0.75 91 4.3 39 13741 0.7 1.8 85.3 5410 77
800 AMA 500L12L 493 95.0 95.3 0.79 0.75 102 4.2 43 15491 0.6 1.7 89.7 5600 77
900 AMA 500L12L 494 95.2 95.4 0.79 0.75 115 4.4 49 17414 0.7 1.8 103.1 6040 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

156 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


HV Pressurized modular motors 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 10000 V 50 Hz


630 AMA 450L2L 2978 94.9 95.0 0.87 0.85 44 5.3 13 2020 0.5 2.3 10.9 3620 83
710 AMA 450L2L 2975 94.8 95.0 0.88 0.86 49 4.8 13 2279 0.5 2.0 10.9 3620 83
800 AMA 450L2L 2973 95.0 95.3 0.88 0.88 55 4.5 12 2570 0.4 1.9 11.7 3770 83
900 AMA 450L2L 2975 95.4 95.6 0.89 0.87 61 4.9 15 2889 0.5 2.1 12.5 3920 83
1000 AMA 450L2L 2980 96.0 96.1 0.89 0.87 68 5.4 16 3204 0.5 2.3 12.9 4070 83
1120 AMA 500L2L 2985 96.0 95.9 0.87 0.84 78 5.5 24 3583 0.5 2.3 17.4 4580 84
1250 AMA 500L2L 2985 96.2 96.2 0.88 0.86 86 5.5 24 3999 0.5 2.3 18.8 4770 84
1400 AMA 500L2L 2985 96.4 96.4 0.88 0.86 95 5.5 26 4479 0.5 2.2 20.1 4960 84
1600 AMA 500L2L 2984 96.5 96.6 0.90 0.89 107 5.3 24 5120 0.5 2.2 21.5 5160 84
1800 AMA 500L2L 2985 96.7 96.8 0.90 0.88 120 5.5 28 5758 0.5 2.2 22.5 5340 84

1500 r/min = 4 poles 10000 V 50 Hz


710 AMA 450L4L 1488 95.3 95.2 0.88 0.85 49 5.8 15 4557 0.6 2.4 22.5 3720 80
800 AMA 450L4L 1488 95.4 95.3 0.87 0.83 56 5.8 19 5135 0.6 2.5 22.5 3730 80
900 AMA 450L4L 1488 95.7 95.7 0.88 0.86 62 6.0 19 5776 0.7 2.5 25.2 3970 80
1000 AMA 450L4L 1487 95.6 95.8 0.88 0.87 68 5.4 19 6424 0.6 2.3 25.2 3970 80
1120 AMA 500L4L 1491 95.4 95.4 0.88 0.86 77 5.6 22 7172 0.5 2.2 44.2 4670 81
1250 AMA 500L4L 1491 95.8 95.9 0.89 0.87 85 5.6 24 8004 0.6 2.1 46.9 4840 81
1400 AMA 500L4L 1491 96.0 96.1 0.89 0.87 95 5.7 26 8964 0.6 2.2 49.8 4990 81
1600
1800
2000
AMA 500L4L
AMA 500L4L
AMA 500L4L
1491
1489
1491
96.2
96.2
96.4
96.3
96.3
96.5
0.88
0.88
0.87
0.86
0.87
0.85
109 5.5 31
123 5.6 33
138 6.0 43
10245
11544
12810
0.5
0.7
0.7
2.1
2.2
2.4
52.4
55.0
58.2
5150
5310
5460
81
81
81
5
2240 AMA 500L4L 1490 96.3 96.5 0.88 0.86 152 5.7 42 14359 0.7 2.2 58.5 5460 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 157


HV Pressurized modular motors 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Speed load load load load inertia weight level LP
kW type r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 10000 V 50 Hz


500 AMA 450L6L 991 95.4 95.3 0.83 0.78 37 6.0 15 4816 0.9 2.4 28.4 3870 78
560 AMA 450L6L 990 95.4 95.4 0.84 0.80 40 5.4 15 5401 0.8 2.2 28.4 3870 78
630 AMA 450L6L 989 95.3 95.5 0.85 0.82 45 5.0 15 6084 0.8 2.0 28.5 3870 78
710 AMA 450L6L 990 95.6 95.7 0.84 0.81 51 5.4 18 6852 0.8 2.1 30.1 3990 78
800 AMA 450L6L 989 95.5 95.8 0.85 0.83 57 4.8 18 7726 0.7 1.9 30.3 4000 78
900 AMA 450L6L 989 95.5 95.8 0.85 0.82 64 4.8 21 8690 0.7 1.9 30.4 4000 78
1000 AMA 500L6L 994 95.9 96.1 0.87 0.85 69 5.6 21 9610 0.6 2.1 61.7 4970 79
1120 AMA 500L6L 994 96.0 96.3 0.87 0.85 77 5.6 24 10763 0.6 2.1 65.2 5120 79
1250 AMA 500L6L 993 96.1 96.3 0.87 0.85 86 5.6 27 12018 0.7 2.1 68.1 5260 79
1400 AMA 500L6L 993 96.2 96.5 0.87 0.85 96 5.6 30 13460 0.7 2.1 71.8 5420 79
1600 AMA 500L6L 992 96.1 96.5 0.88 0.87 109 5.5 30 15397 0.7 2.0 72.8 5430 79

750 r/min = 8 poles 10000 V 50 Hz


710 AMA 500L8L 744 95.5 95.7 0.84 0.81 51 5.8 19 9107 0.8 2.1 71.8 4930 77
800 AMA 500L8L 745 95.7 95.9 0.84 0.80 58 5.6 22 10255 0.7 2.1 76.3 5080 77
900 AMA 500L8L 745 95.9 96.0 0.84 0.80 65 5.5 25 11538 0.7 2.0 80.8 5230 77
1000 AMA 500L8L 745 95.9 96.1 0.83 0.79 72 5.6 28 12819 0.8 2.1 85.2 5380 77
1120 AMA 500L8L 745 96.1 96.3 0.84 0.81 80 5.5 30 14359 0.7 2.0 94.1 5670 77
1250 AMA 500L8L 744 96.0 96.3 0.86 0.83 88 5.5 29 16039 0.8 2.0 94.8 5680 77

5 600 r/min = 10 poles


500 AMA 500L10L 594 94.4 94.6
10000 V 50 Hz
0.82 0.78 37 5.5 16 8034 0.9 2.2 67.4 4750 77
560 AMA 500L10L 594 94.6 94.8 0.83 0.79 41 5.4 17 9002 0.8 2.1 71.9 4900 77
630 AMA 500L10L 594 94.7 95.0 0.84 0.80 46 5.2 18 10130 0.8 2.1 76.3 5050 77
710 AMA 500L10L 595 94.9 95.2 0.83 0.79 52 5.3 21 11404 0.8 2.1 81.6 5200 77
800 AMA 500L10L 595 95.0 95.3 0.83 0.79 58 5.3 24 12849 0.8 2.1 86.1 5350 77

500 r/min = 12 poles 10000 V 50 Hz


355 AMA 500L12L 494 93.3 93.5 0.76 0.70 29 4.1 15 6859 0.6 1.9 54.3 4610 77
400 AMA 500L12L 494 93.6 93.7 0.75 0.69 33 4.2 17 7725 0.6 2.0 58.0 4760 77
450 AMA 500L12L 495 94.0 94.0 0.76 0.70 37 4.3 18 8690 0.6 2.0 65.4 5050 77
500 AMA 500L12L 495 94.0 94.1 0.78 0.72 39 4.9 19 9654 0.7 2.1 80.8 5180 77
560 AMA 500L12L 494 94.1 94.3 0.78 0.73 44 4.8 21 10815 0.7 2.0 85.3 5330 77
630 AMA 500L12L 494 94.3 94.4 0.78 0.73 49 4.7 24 12169 0.7 2.0 89.7 5470 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

158 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, HXR
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

355L 2 610 630 254 70 140 20 355 980 1195 1505 35 1080 380
4
355L
400L
400L
2
4
610
710
710
630
900
900
254
224
224
100
80
110
210
170
210
28
22
28
355
400
400
980
1030
1030
1195
1285
1285
1670
1765
1900
35
35
35
1150
1325
1365
450
430
470
5
450L 2 800 1000 250 80 170 22 450 1075 1385 1985 42 1520 445
450L 4 800 1000 250 110 210 28 450 1075 1385 2120 42 1560 485
500L 2 900 1250 280 90 170 25 500 1175 1510 2320 42 1800 460
500L 4 900 1250 280 120 210 32 500 1175 1510 2455 42 1840 500
560L 4 1000 1600 400 160 300 40 560 1285 1655 3025 48 2350 630

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

355L 2 120 700 745 210 886 55 6317M/C3 6317M/C3


355L 4 120 700 745 210 886 55 6322/C3 6319/C3
400L 2 140 840 840 260 1120 35 6317M/C3 6317M/C3
400L 4 140 840 840 260 1120 35 6324/C3 6319/C3
450L 2 160 950 940 320 1300 40 6317M/C3 6317M/C3
450L 4 160 950 940 320 1300 40 6324/C3 6322/C3
500L 2 170 1050 1050 375 1570 45 6319M/C3 6319M/C3
500L 4 170 1050 1050 375 1570 45 6326/C3 6324/C3
560L 4 230 1170 1190 620 1940 50 6034/C3 + NU1034/C3 NU322/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 159


Pressurized engineered motors, HXR
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

450L 2 800 1000 250 80 170 22 450 1225 1505 1985 42 1520 445

5 450L
500L
500L
4
2
4
800
900
900
1000
1250
1250
250
280
280
110
90
120
210
170
210
28
25
32
450
500
500
1225
1280
1280
1505
1630
1630
2120
2320
2455
42
42
42
1560
1800
1840
485
460
500
560L 4 1000 1600 400 160 300 40 560 1360 1780 3025 48 2350 630

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

450L 2 160 950 940 320 1300 40 6317/C3 6317/C3


450L 4 160 950 940 320 1300 40 6324/C3 6322/C3
500L 2 170 1050 1050 375 1570 45 6319M/C3 6319M/C3
500L 4 170 1050 1050 375 1570 45 6326/C3 6324/C3
560L 4 230 1170 1190 620 1940 50 6034/C3 + NU1034/C3 NU322/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

160 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, HXR
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM3011, IC411

HXR Poles M N P S D E F G GD HD L LA

355L 2 740 680 800 23 70 140 20 62.5 12 1225 1505 25


4
355L
400L
400L
2
4
740
940
940
680
880
880
800
1000
1000
23
28
28
100
80
110
210
170
210
28
22
28
90
71
100
16
14
16
1225
1370
1370
1670
1765
1900
25
30
30
5
450L 4 1080 1000 1150 28 110 210 28 100 16 1495 2120 30
500L 4 1080 1000 1150 28 120 210 32 109 18 1570 2455 30
560L 6 1320 1250 1400 28 160 300 40 147 22 1780 3005 40

HXR Poles LD LE LF T AC AD AE D-end bearing N-end bearing

355L 2 395 1080 130 6 750 822 745 6317M/C3 7317 BM


355L 4 465 1150 130 6 750 822 745 6322/C3 7319 BM
400L 2 425 1315 150 6 840 867 790 6317M/C3 7317 BM
400L 4 465 1355 150 6 840 867 790 6324/C3 7319 BM
450L 4 480 1555 180 6 940 917 840 6324/C3 7322 BM
500L 4 510 1850 200 6 1040 992 915 6326/C3 7324 BM
560L 6 630 2350 250 6 1190 1077 1000 6034/C3 7334 BM
Note! Rain canopy is recommended for outdoor location.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 161


Pressurized engineered motors, HXR
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 3011, IC411

HXR Poles M N P S D E F G GD HD L LA

450L 4 1080 1000 1150 28 110 210 28 100 16 1590 2120 30

5 500L
560L
4
6
1080
1320
1000
1250
1150
1400
28
28
120
160
210
300
32
40
109
147
18
22
1665
1875
2455
3005
30
40

HXR Poles LD LE LF T AC AD AE D-end bearing N-end bearing

450L 4 480 1555 180 6 940 1012 935 6324/C3 7322 BM


500L 4 510 1850 200 6 1040 1087 1010 6326/C3 7324 BM
560L 6 630 2350 250 6 1190 1172 1095 6034/C3 7334 BM
Note! Rain canopy is recommended for outdoor location.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

162 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, HXR
Dimension drawings
Sleeve bearings, 1 < UN 6.6 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

355L 2 610 630 475 70 140 20 355 980 1195 1905 35 1300 600
4
355L
400L
400L
2
4
610
710
710
630
900
900
475
450
450
100
80
110
210
170
210
28
22
28
355
400
400
980
1030
1030
1195
1285
1285
2075
2170
2305
35
35
35
1370
1550
1590
670
655
695
5
450L 2 800 1000 475 80 170 22 450 1075 1385 2390 42 1745 670
450L 4 800 1000 475 110 210 28 450 1075 1385 2525 42 1785 710
500L 2 900 1250 500 90 170 25 500 1175 1510 2705 42 2020 680
500L 4 900 1250 500 120 210 32 500 1175 1510 2840 42 2060 720
560L 2 1000 1600 670 120 210 32 560 1285 1655 3280 48 2530 810
560L 4 1000 1600 670 160 300 40 560 1285 1655 3465 48 2620 900

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

355L 2 120 700 750 210 886 55 EFZLB 9-80 1) EFZLQ 9-80 1)
355L 4 120 700 750 210 886 55 EFZLB 9-90 EFZLQ 9-90
400L 2 140 840 840 260 1120 35 EFZLB 9-80 1) EFZLQ 9-80 1)
400L 4 140 840 840 260 1120 35 EFZLB 9-100 EFZLQ 9-100
450L 2 160 950 940 320 1300 40 EFZLB 9-80 1) EFZLQ 9-80 1)
450L 4 160 950 940 320 1300 40 EFZLB 9-100 2) EFZLQ 9-100 2)
500L 2 170 1050 1050 375 1570 45 EFZLB 9-90 1) EFZLQ 9-90 1)
500L 4 170 1050 1050 375 1570 45 EFZLB 11-100 2) EFZLQ 9-100 2)
560L 2 230 1170 1190 620 1940 50 EFZLB 14-125 1) EFZLQ 14-125 1)
560L 4, 6 230 1170 1190 620 1940 50 EFZLB 14-125 2) EFZLQ 14-125 2)
560L 8 230 1170 1190 620 1940 50 EFZLB 14-140 EFZLQ 14-140
1)
With oil circulation as standard. The above table gives the main dimensions in mm.
2)
With oil circulation as standard for 4 poles.
The customer is responsible for the preparation of the
Note! Axial oat of rotor as standard 8 mm.
foundation. Certied outline drawing is delivered with each
Note! The bearing cannot withstand continuous axial forces.
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 163


Pressurized engineered motors, HXR
Dimension drawings
Sleeve bearings, 6.6 < UN 11 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

450L 2 800 1000 475 80 170 22 450 1225 1505 2390 42 1745 670
4
5 450L
500L
500L
2
4
800
900
900
1000
1250
1250
475
500
500
110
90
120
210
170
210
28
25
32
450
500
500
1225
1280
1280
1505
1630
1630
2525
2705
2840
42
42
42
1785
2020
2060
710
680
720
560L 2 1000 1600 670 120 210 32 560 1360 1780 3280 48 2530 810
560L 4 1000 1600 670 160 300 40 560 1360 1780 3465 48 2620 900

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

450L 2 160 950 940 320 1300 40 EFZLB 9-80 1) EFZLQ 9-80 1)
450L 4 160 950 940 320 1300 40 EFZLB 9-100 2) EFZLQ 9-100 2)
500L 2 170 1050 1050 375 1570 45 EFZLB 9-90 1) EFZLQ 9-90 1)
500L 4 170 1050 1050 375 1570 45 EFZLB 11-100 2) EFZLQ 9-100 2)
560L 2 230 1170 1190 620 1940 50 EFZLB 14-125 1) EFZLQ 14-125 1)
560L 4, 6 230 1170 1190 620 1940 50 EFZLB 14-125 2) EFZLQ 14-125 2)
560L 4 230 1170 1190 620 1940 50 EFZLB 14-140 EFZLQ 14-140
1)
With oil circulation as standard.
2)
With oil circulation as standard for 4 poles.
Note! Axial oat of rotor as standard 8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

164 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

400L 2 750 1250 200 85 170 22 76 400 35 2290 150 880 855 335
400L
450L
450L
4
2
4
750
850
850
1250
1400
1400
200
200
200
110
90
125
210
170
210
28
25
32
100
81
114
400
450
450
35
42
42
2330
2480
2520
150
150
150
880
980
980
855
905
905
335
335
335
5
500L 4 950 1600 200 140 250 36 128 500 42 2830 150 1080 955 335

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1400 545 1450 445 14 20 130 1590 615 1480 565 6319M/C3 6319M/C3
400L 4 1400 545 1450 445 16 20 130 1590 655 1520 565 6324/C3 6319/C3
450L 2 1500 575 1600 465 14 25 230 1760 710 1630 665 6319M/C3 6319M/C3
450L 4 1500 575 1600 465 18 25 230 1760 750 1670 665 6326/C3 6322/C3
500L 4 1605 645 1800 495 20 35 330 1960 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 165


Pressurized engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 4011, IC611 / IP55

AMA Poles M N P S D E F G HD L LA LD LE

400L 4 1080 1000js6 1130 28 110 210 28 100 1755 2330 30 655 1150

5 450L
500L
4
4
1180
1320
1120h8
1250h8
1230
1370
28
28
125
140
210
250
32
36
114
128
1925
2145
2520
2830
40
47
750
860
1300
1540

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L 4 6 855 775 1425 16 50 6324/C3 7319B


450L 4 7 905 825 1525 18 50 6326/C3 7322B
500L 4 8 955 875 1645 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

166 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, AMA
Dimension drawings
Sleeve bearings, 1 < UN 6.6 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

400L 2 750 1250 375 85 170 22 76 400 35 2465 150 880 855 335 1400 545
400L
450L
450L
4
2
4
750
850
850
1250
1400
1400
375
375
400
110
90
125
210
170
210
28
25
32
100
81
114
400
450
450
35
42
42
2505
2655
2720
150
150
150
880
980
980
855
905
905
335
335
335
1400
1500
1500
545
575
575
5
500L 2 950 1600 375 110 210 28 100 500 42 2965 150 1080 955 335 1605 645
500L 4 950 1600 450 140 250 36 128 500 42 3080 150 1080 955 335 1605 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1450 445 14 20 130 1590 790 1655 565 EFZLB9-80 EFZLQ9-80
400L 4 1450 445 16 20 130 1590 830 1695 565 EFZLB9-100 EFZLQ 9-100
450L 2 1600 465 14 25 230 1760 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L 4 1600 465 18 25 230 1760 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 330 1960 995 2045 765 EFZLB9-100 1) EFZLQ9-100 1)
500L 4 1800 495 20 35 330 1960 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L 6 1800 495 20 35 330 1960 1110 2160 765 EFZLB14-140 EFZLQ11-125
1)
With oil circulation as standard.
Note! Axial oat of rotor as standard 8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 167


Pressurized engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

450L 2 850 1400 200 90 170 25 81 450 42 2480 150 980 1005 430
4
5 450L
500L 4
850
950
1400
1600
200
200
125
140
210
250
32
36
114
128
450
500
42
42
2520
2830
150
150
980
1080
1005
1055
430
430

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 575 1600 465 14 25 35 1760 710 1630 665 6319M/C3 6319M/C3
450L 4 1600 575 1600 465 18 25 35 1760 750 1670 665 6326/C3 6322/C3
500L 4 1700 645 1800 495 20 35 135 1960 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

168 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 4011, IC611 / IP55

AMA Poles M N P S D E F G HD L LA LD LE

450L 4 1180 1120h8 1230 28 125 210 32 114 1925 2520 40 750 1100
500L 4 1320 1250h8 1370 28 140 250 36 128 2145 2830 47 860 1340
5
AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

450L 4 7 1000 920 1620 18 50 6326/C3 7322B


500L 4 8 1050 970 1740 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 169


Pressurized engineered motors, AMA
Dimension drawings
Sleeve bearings, 6.6 < UN 11 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

450L 2 850 1400 375 90 170 25 81 450 42 2655 150 980 1005 430 1600 575
4
5 450L
500L
500L
2
4
850
950
950
1400
1600
1600
400
375
450
125
110
140
210
210
250
32
28
36
114
100
128
450
500
500
42
42
42
2720
2965
3080
150
150
150
980
1080
1080
1005
1055
1055
430
430
430
1600
1700
1700
575
645
645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 465 14 25 35 1760 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L 4 1600 465 18 25 35 1760 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 135 1960 995 2045 765 EFZLB9-100 1) EFZLQ9-100 1)
500L 4 1800 495 20 35 135 1960 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L 6 1800 495 20 35 135 1960 1110 2160 765 EFZLB14-140 EFZLQ11-125
1)
With oil circulation as standard.
Note! Axial oat of rotor as standard 8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

170 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

400L 2 750 1250 200 85 170 22 76 400 35 1825 150 880 855 335
4
400L
450L
450L
2
4
750
850
850
1250
1400
1400
200
200
200
110
90
125
210
170
210
28
25
32
100
81
114
400
450
450
35
42
42
1865
1975
2025
150
150
150
880
980
980
855
905
905
335
335
335
5
500L 4 950 1600 200 140 250 36 128 500 42 2265 150 1080 955 335

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1400 545 1450 445 14 20 130 1670 615 1480 565 6319M/C3 6319M/C3
400L 4 1400 545 1450 445 16 20 130 1670 655 1520 565 6324/C3 6319/C3
450L 2 1500 575 1600 465 14 25 230 1870 710 1630 665 6319M/C3 6319M/C3
450L 4 1500 575 1600 465 18 25 230 1870 750 1670 665 6326/C3 6322/C3
500L 4 1605 645 1800 495 20 35 330 2070 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 171


Pressurized engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN 6.6 kV, IM 4011, IC81W / IP55

AMA Poles M N P S D E F G HD L LA LD LE

400L 4 1080 1000js6 1130 28 110 210 28 100 1835 1860 30 655 1150

5 450L
500L
4
4
1180
1320
1120h8
1250h8
1230
1370
28
28
125
140
210
250
32
36
114
128
2035
2255
2020
2260
40
47
750
860
1300
1540

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L 4 6 855 775 1425 16 50 6324/C3 7319B


450L 4 7 905 825 1525 18 50 6326/C3 7322B
500L 4 8 955 875 1645 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

172 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, AMA
Dimension drawings
Sleeve bearings, 1 < UN 6.6 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

400L 2 750 1250 375 85 170 22 76 400 35 2065 150 880 855 335 1400 545
400L
450L
450L
4
2
4
750
850
850
1250
1400
1400
375
375
400
110
90
125
210
170
210
28
25
32
100
81
114
400
450
450
35
42
42
2100
2215
2275
150
150
150
880
980
980
855
905
905
335
335
335
1400
1500
1500
545
575
575
5
500L 2 950 1600 375 110 210 28 100 500 42 2485 150 1080 955 335 1605 645
500L 4 950 1600 450 140 250 36 128 500 42 2595 150 1080 955 335 1605 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1450 445 14 20 130 1670 790 1655 565 EFZLB9-80 EFZLQ9-80
400L 4 1450 445 16 20 130 1670 830 1695 565 EFZLB9-100 EFZLQ 9-100
450L 2 1600 465 14 25 230 1870 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L 4 1600 465 18 25 230 1870 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 330 2070 995 2045 765 EFNLB11-90 EFNLB11-90
500L 4 1800 495 20 35 330 2070 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L 6 1800 495 20 35 330 2070 1110 2160 765 EFZLB14-140 EFZLQ11-125
Note! Axial oat of rotor as standard 8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 173


Pressurized engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 1001, IC81W / IP55
J

AMA Poles A B C D E F G H K L AA AB AC AD

450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 1005 430

5 450L
500L
4
4
850
950
1400
1600
200
200
125
140
210
250
32
36
114
128
450
500
42
42
2025
2265
150
150
980
1080
1005
1055
430
430

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 575 1600 465 14 25 35 1870 710 1630 665 6319M/C3 6319M/C3
450L 4 1600 575 1600 465 18 25 35 1870 750 1670 665 6326/C3 6322/C3
500L 4 1700 645 1800 495 20 35 135 2070 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

174 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Pressurized engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 4011, IC81W / IP55

AMA Poles M N P S D E F G HD L LA LD LE

450L 4 1180 1120h8 1230 28 125 210 32 114 2035 2030 40 750 1100
500L

AMA
4

Poles
1320

T
1250h8

AC
1370

AD
28

AE
140

GD
250

HU
36 128

D-end bearing
2255 2270 47

N-end bearing
860 1340
5
450L 4 7 1000 920 1620 18 50 6326/C3 7322B
500L 4 8 1050 970 1740 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008 175


Pressurized engineered motors, AMA
Dimension drawings
Sleeve bearings, 6.6 < UN 11 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

450L 2 850 1400 375 90 170 25 81 450 42 2215 150 980 1005 430 1600 575
4
5 450L
500L
500L
2
4
850
950
950
1400
1600
1600
400
375
450
125
110
140
210
210
250
32
28
36
114
100
128
450
500
500
42
42
42
2275
2485
2595
150
150
150
980
1080
1080
1005
1055
1055
430
430
430
1600
1700
1700
575
645
645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 465 14 25 35 1870 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L 4 1600 465 18 25 35 1870 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 135 2070 995 2045 765 EFNLB11-90 EFNLB11-90
500L 4 1800 495 20 35 135 2070 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L 6 1800 495 20 35 135 2070 1110 2160 765 EFZLB14-140 EFZLQ11-125

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specied in the order.

176 ABB/ BU Machines / Motors for COG / Pressurized EN 02-2008


Flameproof motors
Squirrel cage three phase high voltage motors,
Up to 4500 kW
For Zone 1 and 2

6
www.abb.com/motors&generators
> Motors
>> Motors and Generators for Hazardous Areas

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 177


Contents Page
General Information 179
Mechanical design 180
Enclosure and cooling 180
Type designation 182
Terminal boxes for ameproof motors 183
Bearings 212
Lubrication 220
Permissible forces 222
Vibrations 223
Rating plate 223
Certicates 224
Notes 225
Technical Data 226
Technical data, Flameproof motors, AMD R IIB 226
Technical data, Flameproof motors, AMD R IIC 230
Technical data, Flameproof motors, AMD T IIB 234
Dimension drawings, Flameproof motors, AMD Rg 242
Dimension drawings, Flameproof motors, AMD R 257
Dimension drawings, Flameproof motors, AMD T 268

ABB reserves the right to change the design,


technical specication and dimensions
without prior notice.

178 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


General Information
ABB engineered motors are tailormade to meet the 630 and 710 mm (vertical execution for 2 pole and IIC
customers needs, and are congured and optimized motors is available on request).
individually for each order and application. Please
The motors are available with the following cooling
contact ABB for further information.
methods and degrees of protection: IC411, IP55 and
This catalogue contains information on ABB squirrel IC511, IP55. The corresponding designations under
cage induction motors, ameproof execution (type NEMA MG1 are TEFC and TEAAC. As an option,
AMD). These high voltage motors have an output range forced cooling (IC416 and IC516) and IP56 protection
from 160 to 4500 kW at 50 Hz and from 250 to 7100 HP are available. The motors are normally designed for
at 60 Hz, with synchronous speeds up to 3600 rpm. continuous operation at their rated output (duty type
S1 to standard IEC 60034-1). The motors can also be
AMD motors can be used for for a wide range of
quoted for other duty cycles.
applications. They can also be operated by variable
speed drives or used as induction generators. More information about AMD motors (output power,
Horizontal or vertical mounting is available, and the voltage ranges and pole numbers) is shown in table
standard shaft heights are 355, 400, 450, 500, 560, below.

Shaft height 355 400 450 - 500 500 - 710 355 400 450 - 500
cast iron cast iron welded cast iron cast iron welded
frame frame frame frame frame frame

Protection & cooling IP55 - IC411 IP55 - IC411 IP55 - IC411 IP55 - IC511 IP55 - IC411 IP55 - IC411 IP55 - IC411

Voltage [kV] 6 6, 11 6, 11 6, 10 6 6, 11 6, 11

Frequency [Hz] 50 50 50 50 50 50 50

Gas group IIB IIB IIB IIB IIC IIC IIC

Note: AMD motors with shaft height 355-500 are available with a rated voltage of 11 kV, on request.
AMD motors for 60 Hz are also available on request.

AMD ameproof squirrel cage induction motors deformations will occur in the event of an explosion
are designed for installation in zone 1 and zone 2 inside the motor. All mechanical gaps and all couplings
according to the following European Standards and IEC are checked to guarantee conformity with the
recommendations: requirements specied in the standards. The certicate
ATEX 94/9/CE number issued by the notied body is stamped on the
EN 60079-0
EN 60079-1
nameplate.
The basic standard certications are for group IIB - T4,
6
EN 60079-7 (when Ex e terminal boxes are tted) which also allows the motors to be used in hazardous
IEC 60079-0 areas in the presence of gas classied as group IIA.
IEC 60079-1 Extensions of the basic certication are available on
IEC 60079-7 (when Ex e terminal boxes are tted) request for temperature classes T5 and T6. AMD 355-
500...R (rib-cooled) motors are also available for
Ex d motors must be certied by an authorized notied IIC - T4 (hydrogen and acetylene gas group). Due to the
body (third party certication). The entire Ex d motor very small radial clearance in the labyrinths, IIC - 2 pole
series already has a standard type certicate. A motors are not available for 60 Hz.
prototype is prepared and tested by a notied body
to guarantee that no transmission of ame and no

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 179


Mechanical design
Enclosure and cooling
Standard combinations used for AMD motors

IC411 / IP 55
The motor has an external shaft-mounted fan using the
surrounding air for cooling. Motor is protected against
dust and water jets.

IC511 / IP 55
The motor is totally enclosed, having an integral air-to-
air heat exchanger using the surrounding medium.

In inverter drives, when a constant torque and wide


speed regulation range are needed, ventilation is forced
by an externally mounted electric motor-driven fan.

IC416 / IP 55

6 The motor has an externally mounted motor-driven fan


using the surrounding air for cooling. Motor is protected
against dust and water jets.

IC516 / IP 55
The motor has an externally mounted motor-driven fan
using the surrounding air for cooling.

180 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


IP55 protection (EN/IEC 60529) means: IP56 protection (EN/IEC 60529) means:

- rst digit -> dust-protected motor: ingress of - rst digit -> see IP55, rst digit denition, on the
dust is not totally prevented but dust left
does not enter in sufcient quantity - second digit -> motor protected against powerful
to interfere with satisfactory water jets: water projected in
operation of the motor powerful jets against the enclosure
- second digit -> motor protected against water jets: from any direction shall have no
water projected by a nozzle against harmful effect
the enclosure from any direction
shall have no harmful effect

IC411 method of cooling (EN/IEC 60034-6) means: IC511 method of cooling (EN/IEC 60034-6) means:

- rst digit -> frame surface cooled: the primary - rst digit -> integral heat exchanger using
coolant is circulated in a closed surrounding medium: the primary
circuit in the motor and surrenders coolant ows in a closed circuit
heat through the external surface and transfers its heat to the
of the motor (in addition to the heat secondary coolant in a heat
transfer via the stator core and other exchanger. The secondary coolant
heat conducting parts) to the nal is air from the surrounding
coolant, which is the surrounding atmosphere. The heat exchanger is
medium. The surface may be plain an integral part of the motor
or ribbed, with or without an outer - second &
shell to improve the heat transfer third digit -> see IC411, second & third digit, on
- second & the left
third digit -> self circulation: the coolant is moved
dependent on the rotation speed of
the main motor, either by action of
the rotor alone or by means of
a component designed for this
purpose and mounted directly on
the rotor of the main motor, or by a
fan or pump unit mechanically driven
by the rotor of the main motor

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 181


IC416 method of cooling (EN/IEC 60034-6) means: IC516 method of cooling (EN/IEC 60034-6) means:

- rst digit -> frame surface cooled: the primary - rst digit -> see IC511, rst digit denition, on
coolant is circulated in a closed the previous page
circuit in the motor and surrenders - second digit -> see IC511, second digit denition,
heat through the external surface on the previous page
of the motor (in addition to the heat
- third digit -> coolant is circulated by an
transfer via the stator core and other
independent component mounted
heat conducting parts) to the nal
on the motor: the coolant is forced
coolant, which is the surrounding
to move by a ventilating device
medium. The surface may be plain
mounted on the motor, but driven
or ribbed, with or without an outer
independently of the main motor
shell to improve the heat transfer
- second digit -> see IC411, second digit denition,
on the previous page
- third digit -> coolant circulated by an independent
component mounted on the motor:
the coolant is forced to move by a
ventilating device mounted on the
motor, but driven independently of
the main motor

Type designation
Type designations for AMD motors consist of a series of
symbols as described below:

AMD ... . . . . . . . F . M
AC Asynchronous motors with Ex d or Ex de protection

355 - 710 center height


S (short), M (medium), L (long), X (extra) frame length

6 2 - ... pole number

R closed motor with rib-cooling


T closed motor with tube-cooling
B horizontal axis motor
V vertical axis motor

A antifriction bearing
S sleeve bearing (IIB only)

B IIB enclosure
C IIC enclosure

x; y constructive variants (electric, mechanical) compared to


the standard solution

F supplied by inverter (if present)

g cast iron frame (if applicable)

M Location of manufacture (M = Vittuone, Italy)

182 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Terminal boxes for ameproof motors
AMD motors are equipped with ameproof main insulation. The terminal box is designed so that
terminal boxes. These terminal boxes are manufactured the protection of the phase conductors against
to withstand the pressure developed in the event of electrical failure within the terminal box is achieved
an internal explosion and to prevent the transmission MAINLYBYSOLIDINSULATION
of ame to the external ambient, where an explosive s %XEPHASESEPARATEDTHETERMINALSARESEPARATED
atmosphere may be present. by insulated walls. The terminal box is designed so
The motors can be equipped with increased safety that phase separation is provided by earthed metallic
terminal boxes (Ex e) on request. In this case additional barriers within the single compartment so as to
measures are applied for increased safety in case of RESTRICTANYELECTRICALBREAKDOWNTOANEARTHFAULT
excessive temperatures, and to avoid arcs and sparks s %XEPHASESEGREGATEDTHETERMINALSARESEGREGATED
inside the terminal boxes. These additional measures in chambers, one for each phase. The terminal box
involve clearance and creepage distances (between is designed so that phase segregation is provided by
terminals and from terminals to metal parts), insulators earthed metallic barriers forming completely distinct
and gasket materials, the degree of mechanical individual phase compartments so as to restrict any
protection, non-loosening terminals, etc. electrical breakdown to an earth fault.
When Ex e main terminal boxes are required, the According to the EN and IEC standards the maximum
following solutions are available: voltage for Ex e execution is 11 kV including positive
s %XESTANDARD variations.
s %XEPHASEINSULATED2AYCHEMSYSTEM THE The terminal boxes are certied according to EN
terminals are insulated with heat shrink tubing. The 60079-0, EN 60079-1, EN 60079-7 and IEC standards,
terminal box is designed so that the protection of the as required for the European market, with additional
phase conductors against electrical failure within the markings:
TERMINALBOXISACHIEVEDMAINLYBYSOLIDINSULATION Installation group: II (surface plant)
s %XEPHASEINSULATED%LASTIMOLDSYSTEM THE Equipment category: 2 (for high protection level)
terminals are insulated with separable connectors Explosive atmosphere: G (explosive gas)
which are easily removed without damaging the

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 183


Standard terminal box for ameproof motors - II2G-Ex d IIB

Technical data: Materials:


Voltage (max.) 8.3, 11, 12.5 kV Box welded steel
Current (max.) 400 A Insulators epoxy resin
No of cables (max.) 1 for phase Cables clamping device ber glass
Cross section of cables Entry cable removable plate not applicable
(min/max) 95/300 mm2/cable Grounding pad stainless steel
Connection terminals M16
Ground connections M12
Mechanical protection degree IP55 (IP56 on request)
Fault level 31.5 kA for 0.25 sec.
- with 95 mm2 min
section of cables
40 kA for 0.25 sec.
- with min 120 mm2
section of cables
- on request with
cables clamping device
Fault level (peak) 79 kA
100 kA with cables
device

184 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Phase segregated terminal box for ameproof motors - II2G-Ex d IIB

Technical data: Materials:


Voltage (max.) 13.8 kV Box welded steel
Current (max.) 850 A Insulators epoxy resin
No of cables (max.) 1 for phase Grounding bolt stainless steel
Cross section of cables Entry cables removable plate not applicable
(min/max) 120/300 mm2/cable
Connection terminals M16
Ground connections M12
Mechanical protection degree IP66
Fault level 40 kA for 0.25 sec.
- with 120 mm2 min
section of cables
Fault level (peak) 100 kA

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 185


Standard terminal box for ameproof motors - II2G-Ex d IIC

Technical data: Materials:


Voltage (max.) 6.6, 11, 12.5 kV Box welded steel
Current (max.) 400 A Insulators epoxy resin
No of cables (max.) 1 for phase Cables clamping device ber glass
Cross section of cables Entry cable removable plate not applicable
(min/max) 95/300 mm2/cable Grounding pad stainless steel
Connection terminals M16
Ground connections M20
Mechanical protection degree IP55 (IP56 on request)
Fault level 31.5 kA for 0.25 sec.
- with 95 mm2 min
section of cables
40 kA for 0.25 sec.
- with 120 mm2 min
section of cables
- on request with cables
clamping device
Fault level (peak) 79 kA

186 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Standard terminal box (small size) for ameproof motors - II2G-Ex d IIC

Technical data: Materials:


Voltage (max.) 6.6 kV Box welded steel
Current (max.) 400 A Insulators epoxy resin
No of cables (max.) 1 for phase Grounding bolt stainless steel
Cross section of cables Entry cables removable plate not applicable
(min/max) 95/300 mm2/cable
Connection terminals M16
Ground connections M12
Mechanical protection degree IP55
Fault level 31.5 kA for 0.25 sec.
- with 95 mm2 min
section of cables
Fault level (peak) 79 kA

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 187


Standard terminal box for ameproof motors - II2G-Ex e II
Derived from Ex d execution
Technical data: Materials:
Voltage (max.) 8.3 kV Box welded steel
Current (max.) 400 A Insulators epoxy resin
No of cables (max.) 1 for phase Cables clamping device ber glass
Cross section of cables Entry cable removable plate not applicable
(min/max) 95/300 mm2/cable Grounding pad stainless steel
Connection terminals with Ex e non loosening
terminals
Ground connections M20
Mechanical protection degree IP55 (IP56 on request)
Fault level 31.5 kA for 0.25 sec.
- with 95 mm2 min
section of cables
40 kA for 0.25 sec.
- with 120 mm2 min
section of cables
- on request with cables
clamping device
Fault level (peak) 79 kA
100 kA with cables
device

188 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Terminal box (small size) for ameproof motors - II2G-Ex e II

Technical data: Materials:


Voltage (max.) 6.6 kV Box welded steel
Current (max.) 400 A Insulators epoxy resin
No of cables (max.) 1 for phase Grounding bolt stainless steel
Cross section of cables Entry cable removable plate in a magnetic material
(min/max) 35/150 mm2/cable
Connection terminals with Ex e non loosening
terminals
Ground connections M12
Mechanical protection degree IP66
Fault level - internal arc
fault current 40.2 kA for 0.25 sec.
- with 120 mm2 min
section of cables

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 189


Terminal box (big size) for ameproof motors - II2G-Ex e II

Technical data: Materials:


Voltage (max.) 11 kV Box welded steel
Current (max.) 400 A Insulators epoxy resin
No of cables (max.) 1 for phase Grounding bolt stainless steel
Cross section of cables Entry cable removable plate in a magnetic material
(min/max) 35/150 mm2/cable
Connection terminals with Ex e non loosening
terminals
Ground connections M12
Mechanical protection degree IP66
Fault level - internal arc
fault current 39.1 kA for 0.3 sec.
- with 120 mm2 min
section of cables

190 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Main terminal box for ameproof motors - II2G-Ex e II
With 6 insulators
Technical data: Materials:
Voltage (max.) 3.3 kV Box welded steel
Current (max.) 800 A Insulators epoxy resin
No of cables (max.) 1 for phase Grounding pad stainless steel
Cross section of cables Entry cables removable plate not applicable
(min/max) 95/300 mm2/cable
Connection terminals M16
Ground connections M12
Mechanical protection degree IP55 (IP56 on request)
Fault level 31.5 kA for 0.25 sec.
- with 95 mm2 min
section of cables
Fault level (peak) 79 kA

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 191


Oversized terminal box for ameproof motors - II2G-Ex e II

Technical data: Materials:


Voltage (max.) 11 kV Box welded steel
Current (max.) 2000 A Insulators epoxy resin
No of cables (max.) 4 for phase Grounding bolt steel
Cross section of cables Entry cables removable plate in a magnetic material
(min/max) 120/300 mm2/cable
Connection terminals M16
Ground connections M10
Mechanical protection degree IP55 (IP56 on request)
Fault level 38.2 kA for 0.2 sec.
- with min section of
cables
Fault level (peak) 95.5 kA

192 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Phase insulated terminal box for ameproof motors - II2G-Ex e II
Raychem system (High mechanical strength solution)
Technical data: Materials:
Voltage (max.) 11 kV Box welded steel
Current (max.) 800 A Connection terminals copper
No of cables (max.) 1 for phase Termination kit supplied by Raychem
Cross section of cables Grounding bolt stainless steel
(min/max) 185/300 mm2/cable Entry cables removable plate in a magnetic material
Connection terminals 35 (bore 35 mm max)
Ground connections M12 For low temperatures (below 40C) II2G-Ex e heating
Mechanical protection degree IP55 (IP56 on request) elements can be mounted inside the II2G-Ex e terminal
Fault level 50 kA for 0.2 sec. box (P=145 W max. power).
- with 185 mm2 min
section of cables
Fault level (peak) 125 kA

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 193


Phase insulated terminal box for ameproof motors - II2G-Ex e II
Elastimold system or Bimold
Technical data: Materials:
Voltage (max.) 11 kV Box welded sheet steel
Current (max.) 630 A Termination kit supplied by Euromold
No of cables (max.) 1 for phase Grounding bolt stainless steel
Cross section of cables Entry cables removable plate in a magnetic material
(min/max) 35/300 mm2/cable
Connection terminals different size For low temperatures (below 20C) II2G-Ex e heating
according to dimensions elements can be mounted inside the II2G-Ex e terminal
and material (Cu/Al) box (P=145 W max. power).
Ground connections M12
Mechanical protection degree IP55 (IP56 on request)
Fault level (peak) 50 kA for 1 sec.
- value guaranteed by
insulators and their
connectors

194 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Phase separated terminal box for ameproof motors - II2G-Ex e II

Technical data: Materials:


Voltage (max.) 11 kV Box welded steel
Current (max.) 400 A internal walls and
No of cables (max.) 1 for phase separations barriers are
Cross section of cables coated by epoxy resin
(min/max) 120/300 mm2/cable and ber glass
Connection terminals M16 (thickness 2 mm)
Ground connections M12 Insulators epoxy resin
Mechanical protection degree IP55 (IP56 on request) Grounding bolt stainless steel
Fault level (peak) 40 kA for 0.25 sec. Entry cables removable plate in a magnetic material
- with 120 mm2 min
section of cables

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 195


Phase segregated terminal box for ameproof motors - II2G-Ex e II

Technical data: Materials:


Voltage (max.) 11 kV Box welded steel
Current (max.) 400 A internal walls and
No of cables (max.) 1 for phase separations barriers are
Cross section of cables coated by epoxy resin
(min/max) 125 or 150 / 300 mm2/ and ber glass
cable (depending on (thickness 2 mm)
max fault level) Insulators epoxy resin
Connection terminals M16 Grounding bolt stainless steel
Ground connections 3xM12 Entry cables removable plate in a magnetic material
Mechanical protection degree IP55 (IP56 on request)
Fault level (peak) 30 kA for 0.5 sec.
40 kA for 0.25 sec.
50 kA for 0.2 sec.

196 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Star point terminal box for ameproof motors - II2G-Ex d IIB
(also certicated in Ex e execution)
Technical data: Materials:
Voltage (max.) 11 kV Box welded steel
Current (max.) 400 A Insulators epoxy resin
No of cables (max.) 1 for phase Grounding bolt stainless steel
Cross section of cables Entry cables removable plate not applicable
(min/max) 300 mm2/cable
Connection terminals M16 - with m2 plates for
star point connection in
brass material
Ground connections M12
Mechanical protection degree IP55 (IP56 on request)

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 197


Current transformers and star point terminal box for ameproof
motors - II2G-Ex d IIB
(protection and measuring CT)
Technical data: Current transformer:
Voltage (max.) 13.8 kV Manufacturer: F.T.M. Opera (MI), Italy
Current (max.) 800 A Ring core type: AOC 80 protection CT
Mechanical protection degree IP66 - standard (no
certication required)
Materials: - II2 G-Ex e II (option)
Box welded steel
Current transformer epoxy casting resin
Insulators epoxy resin
Grounding bolt stainless steel
Star point connection bar copper

198 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Star point terminal box for ameproof motors - II2G-Ex d IIC
(also certicated in Ex e execution)
Technical data: Materials:
Voltage (max.) 12.5 kV Box welded steel
11 kV Ex e execution Insulators epoxy resin
Current (max.) 400 A Grounding bolt stainless steel
No of cables (max.) 1 for phase Entry cables removable plate not applicable
Cross section of cables
(min/max) 300 mm2/cable
Connection terminals M16 - with m2 plates for
star point connection in
brass material
Ground connections M12
Mechanical protection degree IP55 (IP56 on request)

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 199


Main terminal box for ameproof motors II2G-Ex e II
(Derived from Ex d execution)
Technical data: Materials:
Voltage (max.) 8.3 kV Box welded sheet steel
Current (max.) 400 A Insulators epoxy casting resin
No of cables (max.) 1 for phase Grounding bolt stainless steel
Cross section of cables Entry cables removable plate not applicable
(min/max) 150 mm2/cable
Connection terminals M16
Ground connections M12
Mechanical protection degree IP55 (IP56 on request)
Fault level 31 kA for 0.25 sec. (rms)

200 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Current transformers and star point terminal box for ameproof
motors - II2G-Ex e II
(protection and measuring CT)
Technical data: Current transformer:
Voltage (max.) 11 kV Maker: F.T.M. Opera (MI), Italy
Current (max.) 800 A Ring core type: AOC 80 protection CT
Mechanical protection degree IP55 (IP56 on request) II2 G-Ex e II

Materials:
Box welded steel
Current transformer epoxy casting resin
Insulators epoxy resin
Star point connection bar copper

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 201


Auxiliary terminal box outline RTDs for ameproof motors
Available for all types of AMD IIB
Technical data:
Voltage (max.) 550 V
Current (max.) 36 A
Cross section of cables (max.) 1x0.5/10 mm2/cable
Terminal blocks Weidmuller WDU 6/E*
Max. number of terminals 40
Earth cable terminals (N4) Weidmuller TE WPE 6/E*
Protection IP55 (IP56 on request)

For different types and number of terminals, please


contact ABB.

* Weidmuller manufacturer of terminal blocks


7$5%4%70%%nTYPEOFTERMINALBLOCKS

202 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Auxiliary terminal box with surges for ameproof motors
Only Ex d IIB motors
Technical data:
3 wired RTD
Working Voltage 1V
Max. continuous operating
voltage 7.7 V
Rated load current 1/10 mA
Cross section of cables 2.5 mm2/cable
Protection IP55 (IP56 on request)
MTL type SRTD surges
arresters 6 or SD 32T3 for
separately powered
4/20mA loops*
MTL type ETL 7000 earth
cable terminal* 2

For different types and number of terminals, please


contact ABB.

Also available in Ex ia execution

* MTL manufacturer of surge arresters


SRTD, SD 32T3, ETL 7000 type of surge arresters

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 203


Auxiliary terminal box with trasmitters for ameproof motors II2G-Ex d IIB

Technical data:
Temperature transmitters (No 3 or 6) Hart
programmable (Hart protocol)
Input of transmitters resistance thermometers
(2,3,4 wire circuit)
thermocouples
voltages mV or Ohm
3UPPLYVOLTAGE TOTO6
Typical supply voltage 8 .5 to 30 V (depending
of type of transmitter)
Output of transmitters 4/20 mA (2 wire)
Types available* ABB TH 02-Ex
Rosemount type 144H-PC
Rosemount type 248H-
Hart protocol
Rosemount type 644H-
Hart protocol
Mechanical protection degree IP55 (IP56 on request)

Additional terminal blocks included, max 20 Weidmuller


WDU 6/E + 2 earthing + block Weidmuller WPE 6/E.*
Also available in Ex ia execution.

* For other type of transmitter, please contact ABB.


7EIDMULLERnMANUFACTUREROFTERMINALBLOCKS
WDU 6/E, WPE 6/E type of terminal blocks.

204 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Space heater terminal box for ameproof motors
II2G-Ex d IIB / Ex e II / Ex ed IIB
Available for all types of AMD IIB
Technical data:
Voltage (max.) 550 V
Current (max.) 36 A
Cross section of cables (max.) 1x0.5/10 mm2/cable
Terminal blocks Weidmuller WDU 6/E*
Max. number of terminals 4
Earth cable terminals (N2) Weidmuller TE WPE 6/E*
Protection IP55 (IP56 on request)

* For different types and number of terminals, please


contact ABB.
Weidmuller manufacturer of terminal blocks
7$5%4%70%%nTYPEOFTERMINALBLOCKS

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 205


Thermoresistances & space heater terminal box for ameproof motors
II2G-Ex d IIB / Ex e II / Ex ed IIB

Technical data:
Voltage (max.) 550 V
Current (max.) 36 A
Cross section of cables (max.) 1x0.5/10 mm2/cable
Terminal blocks Weidmuller WDU 6/E*
Max. number of terminals 22
Earth cable terminals (N4) Weidmuller TE WPE 6/E*
Protection IP55 (IP56 on request)

* For different types and number of terminals, please


contact ABB.
Weidmuller manufacturer of terminal blocks
7$5%4%70%%nTYPEOFTERMINALBLOCKS

206 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


RTD's terminal box for ameproof motors
II2G-Ex d IIB / Ex e II / Ex ed IIB
Standard application for AMDR IIB
Technical data:
Voltage (max.) 550 V
Current (max.) 36 A
Cross section of cables (max.) 1x0.5/10 mm2/cable
Terminal blocks Weidmuller WDU 6/E*
Max. number of terminals 28
Earth cable terminals (N2) Weidmuller TE WPE 6/E*
Protection IP55 (IP56 on request)

* For different types and number of terminals, please


contact ABB.
Weidmuller manufacturer of terminal blocks
7$5%4%70%%nTYPEOFTERMINALBLOCKS

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 207


Thermoresistances terminal box for ameproof motors
Standard application for AMDR IIC

Technical data:
Voltage (max.) 550 V
Current (max.) 36 A
Cross section of cables (max.) 1x0.5/10 mm2/cable
Terminal blocks Weidmuller WDU 6/E*
Max. number of terminals 28
Earth cable terminals (N2) Weidmuller TE WPE 6/E*
Protection IP55 (IP56 on request)

* For different types and number of terminals, please


contact ABB.
Weidmuller manufacturer of terminal blocks
7$5%4%70%%nTYPEOFTERMINALBLOCKS

208 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Space heater & thermoresistances terminal box for ameproof motors
II2G-Ex d IIC / Ex e II

Technical data:
Voltage (max.) 550 V
Current (max.) 36 A
Cross section of cables (max.) 1x0.5/10 mm2/cable
Terminal blocks Weidmuller WDU 6/E*
Max. number of terminals 22
Earth cable terminals (N4) Weidmuller TE WPE 6/E*
Protection IP55 (IP56 on request)

* For different types and number of terminals, please


contact ABB.
Weidmuller manufacturer of terminal blocks
7$5%4%70%%nTYPEOFTERMINALBLOCKS

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 209


Space heater or RTD's terminal box for ameproof motors
II2G-Ex d IIC / Ex e II

Technical data:
Voltage (max.) 500 V
Current (max.) 24 A
Cross section of cables (max.) 1 x 0.2/4 mm2/cable
Terminal blocks
(max 24 in two rails) type CABUR*
Max. number of terminals 12
Earth cable terminals (N2) type CABUR*
Protection IP66

* For different types and number of terminals, please


contact ABB.

210 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


RTDS terminal box for ameproof motors II2G-Ex d IIC / Ex e II

Technical data:
Voltage (max.) 500 V
Current (max.) 24 A
Cross section of cables (max.) 1x0.2/4 mm2/cable
Terminal blocks type CABUR RN2/4*
Max. number of terminals 40
Earth cable terminals (N2) type CABUR*
Protection IP66

* For different types and number of terminals, please


contact ABB.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 211


Bearings
Antifriction bearings
Horizontally mounted motors up to size 630 (except 2 Vertically mounted motors are provided, as standard,
pole) are, as standard, provided with deep groove ball with an angular contact ball bearing at the N-end
BEARINGSFORGREASELUBRICATIONSIZEISPROVIDED which carries the rotor weight. At the D-end there is an
with rolling bearings for the radial load and a deep axially free spring loaded deep groove ball bearing. The
groove ball bearing at the D-end for rotor axial location. standard degree of protection is IP55.
The N-end bearing is axially free to allow thermal
elongation of the shaft. If this bearing is of the deep
groove type, it is also spring loaded to reduce noise and
vibration. The standard degree of protection is IP55.

Horizontal motors
Standard bearing arrangements for horizontal motors
are listed in tables 1 and 2. The bearing constructions
are shown in the diagrams on the following pages.

Table below: Antifriction bearings for horizontal mounted Table below: Antifriction bearings for horizontal mounted
rib cooled welded AMD. rib cooled, IIB, cast iron, AMD.

Frame size Poles D end N end Frame size Poles D end N end

450 .. RM 2 6317 NU215 355...RgM 2 6316 6316

450 .. RM 4 - 10 6324 6321 355...RgM 4-6 6322 6316

500 .. RM 2 6319 NU217 400...RgM 2 6317 6317

500 .. RM 4 - 12 6326 6324 400...RgM 4-6 6324 6319

Table below: Antifriction bearings for horizontal mounted tube cooled AMD.
Frame Size Number of pole End Frequency
6 50 Hz 60 Hz
500T 2 D 6317 C3 Not standard
N 6317 C3 Not standard
500T 4 D 6324 C3
N 6319 C3
560T 2 D 6319 C3 Not standard
N 6319 C3 Not standard
560T 4 D 6326 C3
N 6322 C3
630T 2 D not available not available
N not available not available
630T 4 D 6330 C3
N 6324 C3
710T 2 D not available not available
N not available not available
710T 4 D 6034 C3
NU1034 EC
N NU322 EC3

212 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Figure below: Antifriction bearing arrangement 630, 4 and more poles

D-end N-end

Some AMD motors with a rolling bearing at the N-end described above. When NU bearings are used, the
are not spring preloaded. rotor is always transport locked and warning labels are
placed on the motor.
For belt drive applications with high radial forces, the
motors can be delivered with a roller (NU) bearing at All the bearings are selected with C3 internal tolerance.
the D-end. Cylindrical roller bearings have a greater There is no difference in bearing arrangements between
radial load capacity than the deep groove ball bearings 50 and 60 Hz motors.

Figure below: Antifriction bearing arrangement 710, 4 and more poles

D-end N-end

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 213


Vertical motors
Vertically mounted motors are generally provided with Standard bearing arrangements for vertical motors are
an angular contact ball bearing at the N-end which listed in the table below. The bearing constructions are
carries the rotor weight. At the D-end there is generally shown in the diagrams on the following pages.
an axially free spring loaded deep groove ball bearing,
All the bearings have C3 internal tolerance. There is no
usually. The standard degree of protection is IP55.
difference in bearing arrangements between 50 and 60
Hz motors.

Table below: Antifriction bearings for vertical mounted Table below: Antifriction bearings for vertical mounted
rib-cooled welded AMD. rib-cooled, IIB, cast iron, AMD.

Frame size Poles D end N end Frame size Poles D end N end

450...RM 2 NU 215 6317 355...R..gM 2 6316 7213

450...RM 4 - 10 6324 7321 355...R..gM 4-6 6322 6316

500...RM 4 - 12 6326 7321 400...R..gM 2 6217 7217

400...R..gM 4-6 6324 6319

Table below: Antifriction bearings for vertical mounted tube-cooled AMD.

Frame size Number of pole End Antifriction bearing type at frequency


50 Hz 60 Hz

500T 4 D 6024 - C3 6024 - C3


500T 4 N 7319 7319

560T 4 D 6026 - C3 6026 - C3


560T 4 N 7322 7322

630T 4 D 6030 - C3 6030 - C3


630T 4 N 7324 7324

6 710T
710T
4
4
D
N
Not standard
Not standard
Not available
Not available
710T 6 D 6034 - c3 6034 - C3
710T 6 N 7330 7330

214 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Figure below: Antifriction bearing, N-end, arrangement with single row angular contact ball bearing.

Figure below: Antifriction bearing, D-end, arrangement with axially free preloaded deep groove ball bearing.

Bearing rating life


The bearing lifetime (L10h) is calculated at 50 Hz
according to ISO R 281-11), with the following results: 6
Table below: AMD with horizontal assembly and rib-cooling circuit, cast iron frame, IIB / IIC, operating at 50 Hz and 60 Hz*.

Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles

355...R..gM >100 000 >100 000 >100 000

400...R..gM >100 000 >100 000 >100 000 >100 000


*)
If the frequency is 60 Hz, then the values in the table should be divided by 1.2.

Table below: AMD with horizontal assembly and rib-cooling circuit, steel frame, IIB / IIC, operating at 50 Hz and 60 Hz*.

Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles

450...RM > 100 000 > 100 000 > 100 000 > 100 000 > 100 000 > 100 000

500...RM > 100 000 > 100 000 > 100 000 > 100 000 > 100 000 > 100 000
*)
If the frequency is 60 Hz, then the values in the table should be divided by 1.2.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 215


Table below: AMD with horizontal assembly and tube-cooling circuit, operating at 50 Hz and 60 Hz*.

Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles

500T > 100 000 > 100 000 > 100 000 > 100 000 > 100 000 > 100 000

560T > 100 000 > 100 000 > 100 000 > 100 000 > 100 000 > 100 000

630T > 50 000 > 50 000 > 60 000 > 60 000 > 80 000

710T > 100 000 > 100 000 > 100 000 > 80 000 > 100 000
*)
If the frequency is 60 Hz, then the values in the table should be divided by 1.2.

Table below: AMD with vertical assembly and rib-cooling circuit, cast iron frame, IIB / IIC, operating at 50 Hz and 60 Hz*.

Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles

355...R..gM 55 000 35 000 42 000

400...R..gM 50 000 53 000 80 000


*)
If the frequency is 60 Hz, then the values in the table should be divided by 1.2.

Table below: AMD with vertical assembly and rib-cooling circuit, steel frame, IIB / IIC, operating at 50 Hz and 60 Hz*.

Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles

450...RM 10 000 > 100 000 > 100 000 > 100 000 > 100 000 > 100 000

500...RM > 50 000 > 60 000 > 60 000 > 70 000 > 80 000
*)
If the frequency is 60 Hz, then the values in the table should be divided by 1.2.

Table below: AMD with vertical assembly and tube-cooling circuit, operating at 50 Hz and 60 Hz*.

6 Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles

500T > 100 000 > 100 000 > 100 000 > 100 000 > 100 000

560T > 100 000 > 100 000 > 100 000 > 100 000 > 100 000

630T > 90 000 > 100 000 > 100 000 > 100 000 > 100 000

710T > 90 000 > 80 000 > 90 000 > 80 000 > 90 000
*)
If the frequency is 60 Hz, then the values in the table should be divided by 1.2.

216 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Lubrication
The bearing arrangements are designed for grease The bearings are lled with the following types of
lubrication and are provided with grease valves in order grease1) before testing at the factory:
to ensure that the correct quantity of grease is applied
Horizontal mounting
for proper lubrication. Re-lubrication must be performed
while the motor is rotating in accordance with the 2 poles: ESSO Unirex N3
maintenance instructions supplied with the motor. Old or 4 and more poles: Lithium k2k or k3k
excess grease is displaced and automatically removed
Vertical mounting
by the grease valve through the outer bearing cover.
All: ESSO Unirex N3
1)
Equivalent types can also be used.

Table below: Lubricating intervals in hours for 50 Hz horizontal mounted rib-cooled, IIB or IIC, welded AMD motors.

Grease (g)
Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles
2 poles 4-n poles
355RM 1500 7000 8760 30 45

400RM 1500 5000 8000 8760 45 70

450RM 1500 5000 8000 8760 8760 45 70

500RM 1200 4500 8000 8760 8760 8760 45 80

Table below: Lubricating intervals in hours for 60 Hz horizontal mounted rib-cooled, IIB or IIC, welded AMD motors.

Grease (g)
Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles 2 poles 4-n poles

355RM 700 6000 8000 30 45

400RM 700 4000 7000 8000 45 70

450RM 700 4000 7000 8000 8760 45 70

500RM 3500 6500 8000 8760 8760 80

Table below: Lubricating intervals in hours for 50 Hz horizontal mounted tube-cooled AMD motors.

Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles


Grease (g)
2 poles 4-n poles
6
500..T 2500 4000 35 70

560..T 1500 4000 5500 8000 8760 8760 45 80

630..T 3500 4500 7000 8500 8760 45 90

710..T 1800 2000 5000 6000 7000 55 x 2

Table below: Lubricating intervals in hours for 60 Hz horizontal mounted tube-cooled AMD motors.

Grease (g)
Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles 2 poles 4-n poles

500..T 3500 35 70

560..T 3000 4500 6500 8760 8760 45 80

630..T 3000 4000 6000 7000 8000 90

710..T 1000 1800 3000 4000 5000 55 x 2

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 217


For vertical motors (except 710 size) the values motors and by 1/3 for tube-cooled motors. For 710 size
indicated above must be reduced by 1/2 for rib-cooled motors the same value as shown above is used.

Table below: Lubricating intervals in hours for 50 Hz horizontal mounted rib-cooled, cast iron, AMD motors.

Grease (g)
Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles 2 poles 4-n poles

355...RgM 3100 8100 33 60

400RgM 2500 7000 41 60

Table below: Lubricating intervals in hours for 60 Hz horizontal mounted rib-cooled cast iron, AMD motors.

Grease (g)
Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles 2 poles 4-n poles

355...RgM 1300 6600 33 60

400RgM 1200 5000 41 60

Table below: Lubricating intervals in hours for 50 Hz vertical mounted rib-cooled, IIB, cast iron, AMD motors.

Grease (g)
Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles 2 poles 4-n poles

355...RgM 1500 4000 5500 33 60

400RgM 1250 3500 5000 21 71.5

Table below: Lubricating intervals Hz in hours for 60 vertical mounted rib-cooled, IIB, cast iron, AMD motors.

Grease (g)
Frame Size 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles 2 poles 4-n poles

6 355...RgM 600 3300 4600 33 60

400RgM 600 2500 4100 21 71.5

The values have been calculated for an ambient motors the maximum allowable bearing wear is smaller
temperature of 40C. If the rated temperature is than for normal motors. Therefore the rated bearing life
different, the given values must be changed: the and lubricating intervals are normally reduced.
lubricating intervals are halved for every 15 K over the
Precise information on lubricating intervals, the type
reference value.
and quantity of grease, and bearing type, is shown on
The lubricating interval must not be greater than one the lubricating plate tted near to every bearing on all
year. motors.
Due to the reduced air gap between the static and
rotating parts of the ame arrestors, for ameproof

218 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Sleeve bearings
The sleeve bearings used in AMD motors are side All sleeve bearings are tted with an oil ring for self-
ange bearings. The bearing at the D-end is the guide lubrication and the bearing shells have provision for
bearing which determines the axial position of the shaft. an external oil supply: in some cases external ood
This means that the thrust faces in the D-end bearing lubrication is required.
shell carry limited axial force. Shaft thermal elongation
will be towards the N-end, where an axially free bearing
is provided.

1 Top half of the housing


2 Positioning pin hole
3 Positioning pin
4 Connection hole for the thrust part oil supply
5 Top sight glass
6 Eye bolt
7 Screw
8 Screw
9 Tap hole
10 Flame arrestor (schematic)
11 Top half of the shell
12 Split line screw
13 Bottom half of the shell
14 Spherical seating
15 Engraved number
16 Recess
17 Tap hole
18 Screw
19 Split line screw
20 Engraved numbers
22 Connection hole for temp measurement of the journal part
23 Oil inlet connection hole
24 Connection hole for the oil sump temp measurement
25 (Water cooling)
26 (Oil cooler)
27 Oil drain plug
28 Metal tabs
29 Oil outlet connection hole
30 Oil outlet pipe with special nut and lead sealing ring
31 Marking

The standard sleeve bearings for AMD motors and the 6


respective lubrication methods are listed below.

Table below: Sleeve bearings for rib-cooled AMD motors.

Frame size Poles D-end N-end Lubrication

355R 2 EFNLB 9-80 EFNLQ 9-80 Self lubrication

355R 4 EFNLB 9-90 EFNLQ 9-80 Self lubrication

400R 2 EFNLB 9-80 EFNLQ 9-80 Self lubrication

400R 4 EFNLB 11-125 EFNLQ 9-100 Self lubrication

450R 2 EFNLB 9-80 EFNLQ 9-80 Self lubrication

450R 4 EFNLB 11-125 EFNLQ 9-100 Self lubrication

500R 2 EFNLB 9-90 EFNLQ 9-90 Self lubrication

500R 4 EFNLB 14-125 EFNLQ 9-100 Self lubrication

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 219


Table below: Sleeve bearings for rib-cooled, cast iron frame, AMD motors.

Frame size Poles D-end N-end Lubrication

355Rg 2 EFNLB 9-80 EFNLQ 9-80 Self lubrication

355Rg 4 EFNLB 9-90 EFNLQ 9-80 Self lubrication

400Rg 2 EFNLB 9-80 EFNLQ 9-80 Self lubrication

400Rg 4 EFNLB 11-125 EFNLQ 9-100 Self lubrication

Table below: Sleeve bearings for tube-cooled AMD motors.

Frame size Poles D-end N-end Lubrication

500T 2 EFNLB 9-80 EFNLQ 9-80 Self lubrication

500T 4 EFNLB 11-125 EFNLQ 9-100 Self lubrication

560T 2 EFNLB 9-90 EFNLQ 9-90 Self lubrication

560T 4 EFNLB 11-125 EFNLQ 9-100 Self lubrication

630MT 2 EFNLB 9-90 EFNLQ 9-90 Self lubrication

630LT 2 EFZLB 9-100 EFZLQ 9-100 Oil circulation

630T 4 EFNLB 14-140 EFNLQ 11-125 Self lubrication

710T 2 EFZLB 11-125 EFZLQ 11-125 Oil circulation

710T 46 EFZLB 14-160 EFZLQ 14-160 Oil circulation

710T 8 EFNLB 14-160 EFNLQ 14-160 Self lubrication

710XT 4 EFZLB 14-180 EFZLQ 14-180 Oil circulation

Lubrication
Mineral oils are used as standard for the bearings of is based on cinematic viscosity at 40C and uses the
6 AMD motors. The oil used must have a viscosity value
as dened in ISO 3448 or SSU. The ISO grade system
abbreviation cSt. The ISO and the SSU viscosity ranges
are shown below.

Table below: ISO and SSU viscosity ranges.

ISO viscosity grade number ISO viscosity range 40C SSU viscosity range 100F

VG 32 28.8 - 35.2 137 164

VG 46 41.4 - 50.6 193 235

VG 68 61.2 - 74.8 284 347

The function of the oil ring can be checked through glass opening on top of the bearing housing and the
the sight glass located in the upper part of the bearing drain screw is located in the bottom part of the housing.
housing. When external oil circulation is required, The recommended oil viscosity is determined by the
connectors are provided for an oil feed and drain. For rotation speed.
self-lubricated bearings, the oil is lled through the sight

220 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Table below: Rotation speed and oil viscosity grade number.

Rotation speed rpm Oil viscosity grade number

< 1200 ISO VG 68 315 SSU/100F

1200...1800 ISO VG 46 214 SSU/100F

> 1800 ISO VG 32 150 SSU/100F

Table below: Recommended oil lubricants.

Supplier ISO VG 32 150 SSU/100F ISO VG 46 214 SSU/100F ISO VG 68 315 SSU/100F

ESSO Terresso 32 Terresso 46 Terresso 68

GULF Harmony 32 Harmony 46 Harmony 68

MOBIL DTE 24 DTE 25 DTE 26

NESTE Paine 32 Paine 46 Paine 68

SHELL Tellus oil S 32 Tellus oil S 46 Tellus oil S 68

TEBOIL Larita oil 32 Larita oil 46 Larita oil 68

Synthetic oils
If synthetic oils are used, they must be approved by By using the synthetic oils listed in the table below, the
the bearing manufacturer. Synthetic oils can be more following changes can be made for self-lubrication only
effective than mineral oils if the ambient temperature is (no combinations allowed, only one change at the same
very cold or hot. With synthetic oils, bearings can be run time):
at higher operating temperatures and the alarm and trip 1. Tables 21 and 23 valid up to ambient
limits can also be increased. Note, however, that some temperature of 50C (instead of 40C).
synthetic oils may not be completely compatible with 2. Tables 21 and 23 valid up to 4000 m.a.s.l.
non-metallic bearing sealings. (instead of 1000 m.a.s.l.).
3. 8000 h of oil change interval.

Table below: Synthetic lubricants approved by the bearing manufacturer.


6
Supplier ISO VG 32 150 SSU/100F ISO VG 46 214 SSU/100F ISO VG 68 315 SSU/100F

Klber Summit SH 32 Summit SH 46 Summit SH 68

MOBIL SHC 624 - SHC 626

SHELL Mandrela Oil AS 32 Mandrela Oil AS 46 Mandrela Oil AS 68

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 221


Permissible forces
Radial forces
If the motor is subject to external radial loads, the Bearing type B is designed to carry limited, non-
standard bearing solutions must be veried by the continuous axial loads.
factory technical department. If oversize bearings are
Bearing type K is designed to carry small continuous
required, the motors explosion proof certication must
axial loads. The standard shaft design, which allows a
also be modied.
certain amount of axial play, cannot be used with this
type of bearing.
Axial forces
Sleeve bearings cannot withstand large axial forces. The temperature rise must be recalculated. In the event
The table below shows approximate values for the axial that bearings have to withstand axial loads please refer
forces that can be supported by the bearings. to ABB, as external oil circulation is probably required.

Table below: Permissible axial load for sleeve bearings.

Bearing size Diameter Axial force(momentary) for Type B Axial force(continuous) for Type K
[N] (lbf) [N] (lbf)

9 80 900 (200) 3000 (675)

9 90 1000 (225) 3500 (790)

9 100 1100 (250) 3500 (790)

14 140 2700 (610) 8950 (2010)

Rotor axial oat


Standard motors with sleeve bearings are equipped oat limits. The standard motor design has a maximum
with a pointer showing the rotor axial oat. One groove 3 mm end oat from the mechanical center. The
is marked on the shaft marking magnetic center. There mechanical center is the midpoint between the rotor
are also grooves on the shaft marking the rotor end end oat limits.

Figure below: Rotor end oat limits.

The motors magnetic center complies with the API must be carried by the driven machine. The coupling
541 standard, which species that the running center must be of the limited axial oat type.
of the rotor must not shift from either side of the stator
The axial oat is reduced to 2 mm in the case of an
mechanical center by more than 2.4 mm.
axial load.
When there is axial oat, the motor cannot withstand
any axial force from the driven machine. All axial force

222 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Vibrations
Standard motors manufactured to IEC standard satisfy Other vibration limit specication, such as IEC 60034-14
the Grade A vibration limits specied in IEC 60034-14. Grade B, NEMA special motor or API 541, are available
The table below shows the maximum accepted values. on request.

Speed range Maximum Relative Shaft Maximum Combined Mechanical and


rpm Displacement Sp-p Electrical Run-out
m m
1800 90 23

> 1800 65 16

Rating plate
Figure below: Rating plate for HV motor according to IEC Figure below: Rating plate for HV motor according to EN

The IEC recommends that the manufacturer provides


the following information on the rating plate: 6
- Name of manufacturer - Rated nominal power factor (cos())
- Manufacturers serial number or identication number - Max. permitted ambient temperature, if higher than
- Identication of manufacturing year +40C
- On rating plate - Min. permitted ambient temperature, if lower than
- Separate data sheet with motor (note in box) -15C
- Manufacturers machine code - Max. altitude above sea level, if higher than 1,000
- Number of phases m.a.s.l. (above sea level)
- Degrees of protection according to IEC 60034-5 - Total weight, if over 30 kg
- Insulation class or permitted temperature rise - If only one rotation direction is permitted, it should be
- Type of duty, if other than S1 (continuous duty) marked with an arrow (not necessarily on the
- Rated nominal power, voltage, frequency, current, rating plate).
speed
- Connection instructions (diagram or text if more than
three connection terminals)
- Nameplate mounted close to or in connection
box.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 223


Certicates
AMD ameproof motors are certied according to ATEX On request, other local certications are available.
Directive 94/9/EC based on EN standards for the
The table below shows all certications currently
European market and according to IEC standards for
available for AMD motors.
other markets.

AMDR / AMDRg
Standard Protection Hazard Category Area Gas Group Temperature
Ambient Class

ATEX Ex d Group II 2G Zone 1-2 IIB/IIC T3-T41)


Ex de
IEC Ex d - - Zone 1-2 IIB/IIC T3-T41)
Ex de
GOST-R 1Ex d Group II - Zone 1-2 IIB/IIC T3-T41)
2Ex de
CCE/DGFASLI Ex d Group II - Zone 1-2 IIB T3-T4
(India) 2) Ex de
CQST 2) Ex d Group II - Zone 1-2 IIB/IIC T3-T4
Ex de
KOREAN Ex d Group II - Zone 1-2 IIB/IIC T3-T41)
(Approval) 3) Ex de
CSA 4) Ex d Class I - Zone 1-2 B T3-T4
UL 4) AEx d
NEC 505 4) Ex d
3)
1)
Cast iron motors are available also for temperature class T5 In progress for AMDR 400 cast iron
2)
In progress for AMDR 355 & 400 cast iron 4)
Available for AMDR IIB motor series only

AMDT
Standard Protection Hazard Category Area Gas Group Temperature
Ambient Class

ATEX Ex d Group II 2G Zone 1-2 IIB T3-T4


Ex de
IEC Ex d - - Zone 1-2 IIB T3-T4
Ex de

6 GOST-R 1Ex d
2Ex de
Group II - Zone 1-2 IIB T3-T4

CQST Ex d Group II - Zone 1-2 IIB T3-T4


Ex de
CCE/DGFASLI Ex d Group II - Zone 1-2 IIB 1) T3-T4
(India) Ex de
KOREAN Ex d Group II - Zone 1-2 IIB T3-T4
(Approval) Ex de
1)
Certication according to Petroleum Rules for petroleum applications in the Indian market. The motors are IIB in any case.

AMDRg & dust explosive atmosphere


Standard Protection Hazard Category Zone Dust type Surface
Ambient Temperature

ATEX Ex tD A21/A22 Group II 2D/3D A21 / A22 Conductive / 85C450C


Non Conductive
IEC Ex tD A21/A22 Group II - A21 / A22 Conductive / 85C450C
Non Conductive

224 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Notes
All ratings in this catalogue are designed for the
following:

- Class F insulation / Maximum temperature rise of


80C by resistance
- Maximum 40C ambient
- Altitude of 1000 meters or less
- Data presented in rating lists are typical values
- Guaranteed values are available on request
- All engineered motors are optimized for the
specied application. Accurate motor data will be
given on request at quotation phase. Legally binding
performance and specication data is given to the
end user once each order is conrmed.
- Please provide load data and starting requirements to
ABB for nal design conrmation.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 225


HV Flameproof motors, AMD R IIB 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


160 AMD 355L2Rg 791 2983 94.2 93.5 0.89 0.88 18 109 4.8 512 0.3 1.2 4.5 2170 79
180 AMD 355L2Rg 790 2982 94.7 94.1 0.91 0.89 20 127 4.7 576 0.4 1.4 4.6 2170 79
200 AMD 355L2Rg 789 2982 94.8 94.4 0.91 0.90 22 137 4.7 641 0.4 1.5 4.7 2170 79
224 AMD 355L2Rg 788 2981 95.1 94.7 0.91 0.90 25 152 5.3 717 0.5 1.6 4.7 2170 79
250 AMD 355L2Rg 787 2981 95.2 94.9 0.90 0.90 28 165 5.9 801 0.5 1.8 4.7 2170 79
315 AMD 355L2Rg 102 2982 95.6 95.5 0.90 0.89 35 213 7.6 1009 0.7 2.3 5.1 2260 79
355 AMD 355L2Rg 103 2983 95.8 95.7 0.90 0.89 40 248 8.8 1137 0.8 2.6 5.5 2370 79
400 AMD 400L2Rg 736 2988 95.6 95.1 0.89 0.88 45 277 10.9 1279 0.7 3.0 8.3 2800 81
450 AMD 400L2Rg 737 2987 95.9 95.5 0.90 0.89 50 303 11.1 1439 0.8 3.2 9.0 2930 81
500 AMD 400L2Rg 738 2987 96.1 95.7 0.90 0.89 56 338 11.7 1598 0.9 3.6 9.6 3070 81
560 AMD 400L2Rg 739 2987 96.3 96.0 0.90 0.90 62 383 12.8 1790 1.0 4.0 10.3 3200 81
560 AMD 450L2R 172 2989 96.3 96.0 0.90 0.90 62 351 10.9 1789 0.8 3.7 16.2 4675 85
630 AMD 450L2R 173 2989 96.6 96.3 0.91 0.91 69 409 11.8 2013 1.0 4.2 17.7 4930 85
710 AMD 450L2R 174 2990 96.7 96.5 0.91 0.91 78 489 13.5 2268 1.2 5.0 19.3 5200 85
800 AMD 500L2R 175 2989 96.9 96.7 0.90 0.91 88 466 14.3 2556 1.0 4.9 33.1 6285 87
900 AMD 500L2R 176 2990 97.1 96.9 0.91 0.91 98 578 16.7 2875 1.3 6.0 35.6 6905 87
1000 AMD 500L2R 177 2989 97.2 97.1 0.91 0.91 109 634 17.0 3194 1.5 6.5 40.6 7520 87

1500 r/min = 4 poles 6000 V 50 Hz


160 AMD 355L4Rg 799 1489 94.6 94.2 0.84 0.80 19 113 7.6 1026 0.9 2.3 6.1 2070 79
180 AMD 355L4Rg 798 1491 95.0 94.5 0.80 0.75 23 150 10.6 1152 1.1 2.8 6.0 2070 79
200 AMD 355L4Rg 797 1491 95.1 94.6 0.79 0.73 26 170 12.5 1281 1.3 3.1 6.0 2070 79
224 AMD 355L4Rg 796 1491 95.3 94.9 0.80 0.75 28 179 12.7 1434 1.3 3.3 6.1 2070 79
280 AMD 355L4Rg 106 1490 95.5 95.4 0.83 0.79 34 189 13.1 1795 1.4 3.5 6.4 2170 79

6 315
355
AMD 355L4Rg
AMD 355L4Rg
107
108
1490
1490
95.8
96.0
95.7
96.0
0.84
0.84
0.81
0.81
38
42
212
242
13.5
14.7
2019
2275
1.6
1.9
3.9
4.4
7.3
7.9
2260
2370
79
79
400 AMD 355L4Rg 109 1491 96.2 96.1 0.84 0.80 48 290 17.7 2562 2.3 5.2 8.6 2500 79
450 AMD 400L4Rg 740 1491 96.3 96.1 0.86 0.83 52 339 18.1 2881 2.1 6.7 12.6 2700 80
500 AMD 400L4Rg 734 1491 96.4 96.3 0.87 0.84 58 369 18.6 3202 2.4 7.2 13.7 2850 80
560 AMD 400L4Rg 735 1491 96.6 96.5 0.88 0.86 64 353 17.0 3586 2.2 7.1 15.6 3060 80
630 AMD 400L4Rg 741 1491 96.7 96.5 0.87 0.85 72 448 22.0 4034 3.2 8.3 17.0 3250 80
630 AMD 450M4R 422 1492 96.8 96.6 0.88 0.86 71 432 20.4 4032 2.7 9.0 27.4 4485 80
710 AMD 450L4R 423 1492 96.9 96.8 0.88 0.86 80 511 23.5 4543 3.3 10.4 29.4 4910 80
800 AMD 450L4R 424 1492 97.1 96.9 0.89 0.87 90 582 25.9 5119 3.9 11.7 33.0 5295 80
900 AMD 500M4R 425 1492 97.1 97.0 0.88 0.86 101 583 28.7 5760 3.5 12.6 46.8 5920 80
1000 AMD 500M4R 426 1492 97.2 97.1 0.89 0.87 112 666 31.6 6398 4.0 14.3 54.0 6450 80
1120 AMD 500L4R 427 1492 97.3 97.3 0.89 0.87 125 741 34.3 7166 4.6 15.8 59.0 7100 80
1250 AMD 500L4R 428 1492 97.4 97.4 0.89 0.88 138 791 34.7 8000 5.1 16.9 70.6 7925 80

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

226 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, AMD R IIB 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


225 AMD 355L6Rg 112 990 94.5 94.5 0.80 0.75 29 149 12.3 2171 2.1 4.1 7.4 2150 76
250 AMD 355L6Rg 99 990 94.8 94.8 0.80 0.76 32 168 13.2 2412 2.4 4.6 8.3 2230 76
280 AMD 355L6Rg 100 989 95.1 95.1 0.80 0.77 35 175 13.9 2704 2.5 4.8 8.9 2340 76
315 AMD 355L6Rg 101 989 95.2 95.2 0.81 0.77 40 189 15.2 3042 2.7 5.2 9.2 2490 76
355 AMD 400L6Rg 742 992 95.8 95.7 0.80 0.76 45 234 19.0 3418 2.6 6.7 13.4 2740 77
400 AMD 400L6Rg 743 992 96.1 95.9 0.80 0.75 50 276 21.6 3849 3.1 7.8 15.1 2940 77
450 AMD 400L6Rg 744 993 96.2 96.0 0.78 0.73 58 350 27.3 4327 4.0 9.9 16.7 3160 77
500 AMD 400L6Rg 745 993 96.4 96.2 0.81 0.77 62 351 25.6 4810 4.0 9.8 19.5 3400 77
500 AMD 450M6R 433 993 96.6 96.6 0.86 0.85 58 340 17.2 4807 4.1 9.3 38.7 4335 76
560 AMD 450M6R 434 993 96.7 96.7 0.87 0.85 64 381 19.0 5384 4.7 10.4 41.4 4505 76
630 AMD 450L6R 435 993 96.8 96.9 0.87 0.85 72 422 20.6 6057 5.3 11.4 45.6 5040 76
710 AMD 450L6R 436 993 96.8 97.0 0.87 0.85 81 487 23.1 6825 6.2 13.0 53.7 5515 76
800 AMD 500M6R 437 993 96.8 96.8 0.86 0.84 92 515 28.4 7695 6.5 15.4 67.2 6145 76
900 AMD 500M6R 438 994 97.0 97.0 0.86 0.83 104 637 34.2 8651 8.2 18.8 75.2 6560 76
1000 AMD 500L6R 439 994 97.0 97.1 0.86 0.84 115 707 37.4 9612 9.2 20.7 81.9 7210 76
1120 AMD 500L6R 440 993 97.1 97.2 0.87 0.85 128 743 38.6 10769 9.8 21.9 93.9 7840 76

750 r/min = 8 poles 6000 V 50 Hz


180 AMD 400L8Rg 746 740 94.5 94.7 0.80 0.75 23 114 10.2 2323 2.0 4.9 12.2 2440 70
200 AMD 400L8Rg 747 739 94.6 94.9 0.81 0.78 25 114 9.9 2585 2.0 4.8 13.3 2570 70
225 AMD 400L8Rg 748 741 95.1 95.1 0.79 0.74 29 154 13.2 2900 2.8 6.5 14.4 2680 70
250 AMD 400L8Rg 749 740 95.2 95.3 0.80 0.76 31 161 13.6 3224 2.9 6.9 15.6 2800 70
280 AMD 400L8Rg 750 741 95.4 95.5 0.80 0.75 35 192 15.7 3608 3.5 8.2 17.8 3150 70
315 AMD 400L8Rg 751 741 95.6 95.7 0.80 0.75 40 212 17.6 4060 3.9 9.0 18.9 3280 70
315
355
AMD 450M8R
AMD 450M8R
447
448
743
743
95.8
95.9
95.9
96.0
0.84
0.84
0.81
0.81
38
42
198
225
13.6
15.0
4049
4563
3.4
3.9
8.0
8.9
33.3
37.3
3905
4195
75
75
6
400 AMD 450M8R 449 743 96.2 96.3 0.84 0.81 48 260 17.0 5139 4.5 10.3 41.4 4475 75
450 AMD 450L8R 450 744 96.2 96.3 0.84 0.81 54 305 19.6 5779 5.4 12.3 47.0 5085 75
500 AMD 450L8R 451 744 96.3 96.4 0.84 0.81 59 337 21.2 6421 6.0 13.6 52.4 5455 75
560 AMD 500M8R 452 744 96.3 96.3 0.82 0.78 68 377 26.8 7190 6.2 14.5 65.7 6060 75
630 AMD 500M8R 453 744 96.4 96.4 0.82 0.79 77 424 29.6 8088 7.0 16.3 73.7 6430 75
710 AMD 500M8R 454 744 96.6 96.6 0.82 0.77 87 518 35.6 9108 8.7 19.9 83.8 6945 75
800 AMD 500L8R 455 744 96.7 96.7 0.83 0.79 96 538 36.4 10269 9.0 21.3 94.6 7820 75
900 AMD 500L8R 456 744 96.7 96.8 0.83 0.80 108 590 39.6 11555 10.0 23.3 102.7 8230 75

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 227


HV Flameproof motors, AMD R IIB 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


200 AMD 450M10R 180 593 94.8 94.9 0.78 0.74 26 121 11.5 3219 2.6 5.9 27.9 3540 75
225 AMD 450M10R 181 594 95.0 95.1 0.78 0.73 29 144 13.5 3618 3.2 7.0 30.6 3710 75
250 AMD 450M10R 182 594 95.2 95.3 0.79 0.74 32 152 14.0 4022 3.4 7.4 33.4 3895 75
280 AMD 450M10R 183 594 95.5 95.5 0.78 0.73 36 182 16.3 4500 4.1 8.9 38.8 4255 75
315 AMD 450M10R 184 594 95.6 95.7 0.79 0.74 40 198 17.5 5064 4.5 9.7 42.9 4530 75
355 AMD 450L10R 185 594 95.7 95.8 0.79 0.75 45 222 19.5 5707 5.0 10.8 47.2 5050 75
400 AMD 450L10R 186 594 95.8 95.9 0.79 0.75 51 251 21.7 6430 5.7 12.2 52.6 5420 75
450 AMD 500M10R 187 594 95.9 95.9 0.80 0.76 57 281 23.3 7232 6.0 13.7 66.6 6020 75
500 AMD 500M10R 188 594 96.0 96.0 0.80 0.76 63 315 25.8 8034 6.8 15.3 74.8 6385 75
560 AMD 500M10R 189 595 96.0 96.0 0.80 0.76 70 360 29.1 8995 7.9 17.4 85.0 6905 75
630 AMD 500L10R 190 595 96.1 96.1 0.79 0.75 80 425 34.7 10116 9.4 20.6 85.8 7670 75
710 AMD 500L10R 191 595 96.1 96.2 0.80 0.75 89 465 37.8 11404 10.4 22.5 91.9 8190 75

500 r/min = 12 poles 6000 V 50 Hz


355 AMD 500M12R 192 495 95.5 95.5 0.72 0.66 50 231 25.8 6851 6.2 12.9 66.5 6020 75
400 AMD 500M12R 193 494 95.6 95.7 0.74 0.69 55 241 26.6 7725 6.5 13.4 74.7 6440 75
450 AMD 500M12R 194 494 95.7 95.8 0.74 0.69 61 270 29.6 8691 7.3 15.0 80.8 6750 75
500 AMD 500L12R 195 494 95.8 95.9 0.74 0.70 68 293 31.7 9658 8.0 16.3 91.8 7605 75
560 AMD 500L12R 196 495 95.8 95.8 0.73 0.67 77 360 39.1 10806 10.0 20.0 95.8 8210 75

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

228 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, AMD R IIB 11000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 11000 V 50 Hz


280 AMD 400L2Rg 752 2986 95.0 94.6 0.89 0.88 17 105 4.2 895 0.6 2.0 8.3 2800 81
315 AMD 400L2Rg 753 2987 95.3 94.9 0.89 0.88 19 122 4.9 1007 0.6 2.3 8.9 2930 81
355 AMD 400L2Rg 754 2987 95.5 95.2 0.90 0.89 22 137 5.0 1135 0.8 2.6 9.6 3070 81
400 AMD 450L2R 762 2990 95.5 95.0 0.91 0.90 24 164 5.0 1278 0.8 3.3 16.3 4675 85
450 AMD 450L2R 763 2990 95.7 95.3 0.91 0.90 27 181 5.6 1437 0.8 3.6 16.3 4675 85
500 AMD 450L2R 764 2989 96.0 95.6 0.92 0.91 30 195 5.5 1597 1.0 3.9 17.8 4930 85
560 AMD 500L2R 889 2990 95.8 95.4 0.92 0.91 33 223 6.6 1788 1.0 4.4 33.1 6285 87
630 AMD 500L2R 773 2990 96.1 95.7 0.92 0.91 38 254 7.4 2012 1.2 5.0 33.1 6285 87
710 AMD 500L2R 774 2990 96.3 96.0 0.92 0.92 42 285 7.7 2268 1.4 5.6 35.8 6905 87

1500 r/min = 4 poles 11000 V 50 Hz


315 AMD 400L4Rg 755 1490 95.2 95.0 0.87 0.85 20 118 6.1 2019 1.6 4.2 12.6 2700 80
355 AMD 400L4Rg 756 1491 95.5 95.3 0.87 0.85 22 137 6.9 2274 1.8 5.0 13.7 2850 80
400 AMD 400L4Rg 757 1491 95.8 95.7 0.87 0.86 25 146 7.2 2562 1.9 5.1 15.3 3060 80
450 AMD 400L4Rg 758 1491 95.9 95.7 0.88 0.86 28 183 8.5 2882 2.6 6.6 17.0 3490 80
500 AMD 450M4R 766 1491 96.1 96.0 0.89 0.88 31 179 8.0 3202 2.2 6.9 27.7 4485 80
560 AMD 450L4R 767 1493 96.4 96.2 0.88 0.85 35 226 10.9 3582 2.6 8.7 29.6 4910 80
630 AMD 500M4R 775 1493 96.6 96.4 0.88 0.85 39 258 13.0 4028 2.7 10.4 46.8 5920 80
710 AMD 500M4R 776 1493 96.7 96.5 0.87 0.84 44 286 14.7 4540 3.0 11.5 46.8 5920 80
800 AMD 500L4R 890 1493 96.9 96.8 0.89 0.86 49 323 14.8 5116 3.7 12.8 59.2 7100 80
900 AMD 500L4R 777 1493 97.0 96.9 0.89 0.87 55 357 16.2 5756 4.1 14.0 59.2 7100 80

1000 r/min = 6 poles 11000 V 50 Hz


250 AMD 400L6Rg 759 994 94.8 94.4 0.76 0.71 18 101 9.0 2401 2.1 5.0 13.6 2740 77
280 AMD 400L6Rg 760 994 95.1 94.9 0.79 0.75 20 101 8.4 2691 2.1 5.0 15.2 2940 77
315
355
AMD 400L6Rg
AMD 450M6R
761
768
994
993
95.4
95.7
95.1
95.7
0.78
0.87
0.73
0.85
22
23
124
121
10.1
6.7
3025
3413
2.6
2.5
6.1
6.5
16.9
38.7
3160
4335
77
76
6
400 AMD 450M6R 769 994 95.9 95.9 0.86 0.84 25 148 7.9 3845 3.1 7.7 38.7 4335 76
450 AMD 450M6R 770 994 96.1 96.0 0.85 0.83 29 169 9.6 4323 3.3 8.8 41.2 4505 76
500 AMD 450L6R 771 994 96.2 96.3 0.87 0.85 32 181 9.4 4806 3.9 9.4 45.7 5040 76
560 AMD 450L6R 772 995 96.4 96.3 0.86 0.83 36 225 12.3 5376 4.6 11.7 53.5 5515 76
630 AMD 500M6R 779 993 96.3 96.3 0.86 0.83 40 211 12.9 6057 4.3 12.1 67.2 6145 76
710 AMD 500L6R 780 993 96.6 96.6 0.86 0.84 45 239 14.2 6825 5.0 13.8 81.9 7210 76
800 AMD 500L6R 781 994 96.7 96.6 0.86 0.83 51 290 17.0 7688 6.2 16.3 81.9 7210 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 229


HV Flameproof motors, AMD R IIC 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


280 AMD 355L2RHg 679 2981 95.3 95.1 0.90 0.89 31 181 6.9 897 0.6 1.9 4.7 2170 79
315 AMD 355L2RHg 680 2982 95.6 95.5 0.90 0.89 35 213 7.6 1009 0.7 2.3 5.1 2260 79
355 AMD 355L2RHg 681 2983 95.8 95.7 0.90 0.89 40 248 8.8 1137 0.8 2.6 5.5 2370 79
400 AMD 400L2RHg 832 2987 95.6 95.1 0.89 0.88 45 277 10.9 1279 0.7 3.0 8.3 2800 81
450 AMD 400L2RHg 833 2988 95.9 95.5 0.90 0.89 50 303 11.1 1439 0.8 3.2 9.0 2930 81
560 AMD 450L2RH 31 2989 96.3 96.0 0.90 0.90 62 351 10.9 1789 0.8 3.7 16.2 4935 85
630 AMD 450L2RH 391 2989 96.6 96.3 0.91 0.91 69 409 11.8 2013 1.0 4.2 17.7 5190 85
710 AMD 450L2RH 392 2990 96.7 96.5 0.91 0.91 78 489 13.5 2268 1.2 5.0 19.3 5460 85
900 AMD 500L2RH 393 2990 97.1 96.9 0.91 0.91 98 578 16.7 2875 1.3 6.0 35.6 7185 87
1000 AMD 500L2RH 394 2989 97.2 97.1 0.91 0.91 109 634 17.0 3194 1.5 6.5 40.6 7805 87

1500 r/min = 4 poles 6000 V 50 Hz


250 AMD 355L4RHg 664 1490 95.3 95.2 0.82 0.78 31 173 12.7 1602 1.2 3.2 6.1 2070 79
280 AMD 355L4RHg 665 1490 95.5 95.4 0.83 0.79 34 189 13.1 1795 1.4 3.5 6.4 2170 79
315 AMD 355L4RHg 694 1490 95.8 95.7 0.84 0.81 38 212 13.5 2019 1.6 3.9 7.3 2260 79
355 AMD 355L4RHg 695 1490 96.0 96.0 0.84 0.81 42 242 14.7 2275 1.9 4.4 7.9 2370 79
400 AMD 355L4RHg 666 1491 96.2 96.1 0.84 0.80 48 290 17.7 2562 2.3 5.2 8.6 2500 79
450 AMD 400L4RHg 842 1491 96.3 96.1 0.86 0.83 52 339 18.1 2881 2.1 6.7 12.6 2700 80
500 AMD 400L4RHg 837 1491 96.4 96.3 0.87 0.84 58 369 18.6 3202 2.4 7.2 13.7 2850 80
560 AMD 400L4RHg 838 1491 96.6 96.5 0.88 0.86 64 353 17.0 3586 2.2 7.1 15.6 3060 80
630 AMD 450M4RH 123 1492 96.8 96.6 0.88 0.86 71 432 20.4 4032 2.7 9.0 27.4 4810 80
710 AMD 450L4RH 124 1492 96.9 96.8 0.88 0.86 80 511 23.5 4543 3.3 10.4 29.4 5220 80
800 AMD 450L4RH 125 1492 97.1 96.9 0.89 0.87 90 582 25.9 5119 3.9 11.7 33.0 5605 80
900 AMD 500M4RH 126 1492 97.1 97.0 0.88 0.86 101 583 28.7 5760 3.5 12.6 46.8 6245 80

6 1120 AMD 500L4RH 127 1492 97.3 97.3 0.89 0.87 125 741 34.3 7166 4.6 15.8 59.0 7445 80

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

230 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, AMD R IIC 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


225 AMD 355L6RHg 707 990 94.5 94.5 0.80 0.75 29 149 12.3 2171 2.1 4.1 7.4 2150 76
250 AMD 355L6RHg 708 990 94.8 94.8 0.80 0.76 32 168 13.2 2412 2.4 4.6 8.3 2230 76
280 AMD 355L6RHg 715 989 95.1 95.1 0.80 0.77 35 175 13.9 2704 2.5 4.8 8.9 2340 76
315 AMD 355L6RHg 709 989 95.2 95.2 0.81 0.77 40 189 15.2 3042 2.7 5.2 9.2 2490 76
355 AMD 400L6RHg 851 992 95.8 95.7 0.80 0.76 45 234 19.0 3418 2.6 6.7 13.4 2740 77
400 AMD 400L6RHg 850 992 96.1 95.9 0.80 0.75 50 276 21.6 3849 3.1 7.8 15.1 2940 77
450 AMD 400L6RHg 852 993 96.2 96.0 0.78 0.73 58 350 27.3 4327 4.0 9.9 16.7 3160 77
500 AMD 450M6RH 132 993 96.6 96.6 0.86 0.85 58 340 17.2 4807 4.1 9.3 38.7 4660 76
560 AMD 450M6RH 133 993 96.7 96.7 0.87 0.85 64 381 19.0 5384 4.7 10.4 41.4 4830 76
630 AMD 450L6RH 134 993 96.8 96.9 0.87 0.85 72 422 20.6 6057 5.3 11.4 45.6 5355 76
710 AMD 450L6RH 135 993 96.8 97.0 0.87 0.85 81 487 23.1 6825 6.2 13.0 53.7 5825 76
800 AMD 500M6RH 136 993 96.8 96.8 0.86 0.84 92 515 28.4 7695 6.5 15.4 67.2 6470 76
900 AMD 500M6RH 137 994 97.0 97.0 0.86 0.83 104 637 34.2 8651 8.2 18.8 75.2 6885 76
1000 AMD 500L6RH 138 994 97.0 97.1 0.86 0.84 115 707 37.4 9612 9.2 20.7 81.9 7560 76
1120 AMD 500L6RH 139 993 97.1 97.2 0.87 0.85 128 743 38.6 10769 9.8 21.9 93.9 8185 76

750 r/min = 8 poles 6000 V 50 Hz


180 AMD 400L8RHg 858 740 94.5 94.7 0.80 0.75 23 114 10.2 2323 2.0 4.9 12.2 2440 70
200 AMD 400L8RHg 856 739 94.6 94.9 0.81 0.78 25 114 9.9 2585 2.0 4.8 13.3 2570 70
225 AMD 400L8RHg 853 741 95.1 95.1 0.79 0.74 29 154 13.2 2900 2.8 6.5 14.4 2680 70
250 AMD 400L8RHg 854 740 95.2 95.3 0.80 0.76 31 161 13.6 3224 2.9 6.9 15.6 2800 70
280 AMD 400L8RHg 855 741 95.4 95.5 0.80 0.75 35 192 15.7 3608 3.5 8.2 17.8 3150 70
315 AMD 400L8RHg 857 741 95.6 95.7 0.80 0.75 40 212 17.6 4060 3.9 9.0 18.9 3280 70
315 AMD 450M8RH 146 743 95.8 95.9 0.84 0.81 38 198 13.6 4049 3.4 8.0 33.3 4230 75
355
400
AMD 450M8RH
AMD 450M8RH
147
148
743
743
95.9
96.2
96.0
96.3
0.84
0.84
0.81
0.81
42
48
225
260
15.0
17.0
4563
5139
3.9
4.5
8.9 37.3
10.3 41.4
4520
4800
75
75
6
450 AMD 450L8RH 149 744 96.2 96.3 0.84 0.81 54 305 19.6 5779 5.4 12.3 47.0 5710 75
500 AMD 450L8RH 150 744 96.3 96.4 0.84 0.81 59 337 21.2 6421 6.0 13.6 52.4 5765 75
560 AMD 500M8RH 151 744 96.3 96.3 0.82 0.78 68 377 26.8 7190 6.2 14.5 65.7 6385 75
630 AMD 500M8RH 152 744 96.4 96.4 0.82 0.79 77 424 29.6 8088 7.0 16.3 73.7 6755 75
800 AMD 500L8RH 153 744 96.7 96.7 0.83 0.79 96 538 36.4 10269 9.0 21.3 94.6 8165 75

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 231


HV Flameproof motors, AMD R IIC 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


200 AMD 450M10RH 154 593 94.8 94.9 0.78 0.74 26 121 11.5 3219 2.6 5.9 27.9 3865 75
225 AMD 450M10RH 155 594 95.0 95.1 0.78 0.73 29 144 13.5 3618 3.2 7.0 30.6 4035 75
250 AMD 450M10RH 156 594 95.2 95.3 0.79 0.74 32 152 14.0 4022 3.4 7.4 33.4 4220 75
280 AMD 450M10RH 157 594 95.5 95.5 0.78 0.73 36 182 16.3 4500 4.1 8.9 38.8 4580 75
315 AMD 450M10RH 158 594 95.6 95.7 0.79 0.74 40 198 17.5 5064 4.5 9.7 42.9 4855 75
355 AMD 450L10RH 159 594 95.7 95.8 0.79 0.75 45 222 19.5 5707 5.0 10.8 47.2 5365 75
400 AMD 450L10RH 160 594 95.8 95.9 0.79 0.75 51 251 21.7 6430 5.7 12.2 52.6 5735 75
450 AMD 500M10RH 161 594 95.9 95.9 0.80 0.76 57 281 23.3 7232 6.0 13.7 66.6 6340 75
500 AMD 500M10RH 162 594 96.0 96.0 0.80 0.76 63 315 25.8 8034 6.8 15.3 74.8 6710 75
630 AMD 500L10RH 163 595 96.1 96.1 0.79 0.75 80 425 34.7 10116 9.4 20.6 85.8 8015 75

500 r/min = 12 poles 6000 V 50 Hz


355 AMD 500M12RH 164 495 95.5 95.5 0.72 0.66 50 231 25.8 6851 6.2 12.9 66.5 6340 75
400 AMD 500M12RH 165 494 95.6 95.7 0.74 0.69 55 241 26.6 7725 6.5 13.4 74.7 6765 75
450 AMD 500M12RH 166 494 95.7 95.8 0.74 0.69 61 270 29.6 8691 7.3 15.0 80.8 7075 75
500 AMD 500L12RH 167 494 95.8 95.9 0.74 0.70 68 293 31.7 9658 8.0 16.3 91.8 7950 75

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

232 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, AMD R IIC 11000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 11000 V 50 Hz


400 AMD 450L2RH 860 2990 95.5 95.0 0.91 0.90 24 164 5.0 1278 0.8 3.3 16.3 4935 85
450 AMD 450L2RH 859 2990 95.7 95.3 0.91 0.90 27 181 5.6 1437 0.8 3.6 16.3 4935 85
500 AMD 500L2RH 892 2990 95.6 95.1 0.92 0.91 30 197 5.9 1597 0.9 4.0 33.1 6600 87
560 AMD 500L2RH 891 2990 95.8 95.4 0.92 0.91 33 223 6.6 1788 1.0 4.5 33.1 6600 87
630 AMD 500L2RH 867 2990 96.1 95.7 0.92 0.91 38 254 7.4 2012 1.2 5.0 33.1 6600 87
710 AMD 500L2RH 868 2990 96.3 96.0 0.92 0.92 42 285 7.7 2268 1.4 5.6 35.8 7185 87

1500 r/min = 4 poles 11000 V 50 Hz


315 AMD 400L4RHg 836 1490 95.2 95.0 0.87 0.85 20 118 6.1 2019 1.6 4.2 12.6 2700 80
355 AMD 400L4RHg 841 1491 95.5 95.3 0.87 0.85 22 137 6.9 2274 1.8 5.0 13.7 2850 80
400 AMD 450L4RH 894 1493 95.9 95.6 0.88 0.86 25 153 7.4 2559 1.7 6.1 29.6 5220 80
450 AMD 450L4RH 893 1492 96.0 95.8 0.88 0.86 28 170 8.2 2879 1.9 6.7 29.6 5220 80
500 AMD 450L4RH 861 1492 96.3 96.0 0.88 0.86 31 189 9.1 3199 2.1 7.4 29.6 5220 80
560 AMD 500M4RH 874 1494 96.3 96.1 0.88 0.85 35 235 11.7 3581 2.5 9.4 45.3 6100 80
630 AMD 500L4RH 870 1492 96.6 96.5 0.90 0.88 38 235 10.5 4031 2.7 9.5 56.6 7200 80
710 AMD 500L4RH 871 1493 96.7 96.6 0.89 0.87 43 260 12.2 4542 2.9 10.5 56.3 7200 80
900 AMD 500L4RH 869 1493 97.0 96.9 0.89 0.87 55 357 16.2 5756 4.1 14.0 59.2 7445 80

1000 r/min = 6 poles 11000 V 50 Hz


250 AMD 400L6RHg 845 994 94.8 94.4 0.76 0.71 18 101 9.0 2401 2.1 5.0 13.6 2740 77
280 AMD 400L6RHg 844 994 95.1 94.9 0.79 0.75 20 101 8.4 2691 2.1 5.0 15.2 2940 77
315 AMD 400L6RHg 843 994 95.4 95.1 0.78 0.73 22 124 10.1 3025 2.6 6.1 16.9 3160 77
355 AMD 450M6RH 866 993 95.7 95.7 0.87 0.85 23 121 6.7 3413 2.5 6.5 38.7 4660 76
400 AMD 450M6RH 865 994 95.9 95.9 0.86 0.84 25 148 7.9 3845 3.1 7.7 38.7 4660 76

6
450 AMD 450L6RH 863 994 96.2 96.1 0.86 0.83 29 167 9.4 4322 3.3 8.9 45.4 5355 76
500 AMD 450L6RH 864 994 96.2 96.3 0.87 0.85 32 181 9.4 4806 3.9 9.4 45.7 5355 76
560 AMD 500M6RH 876 993 96.2 96.1 0.85 0.83 36 194 12.1 5383 3.9 11.2 63.2 6200 76
630 AMD 500M6RH 875 994 96.3 96.2 0.85 0.81 41 239 14.8 6053 4.9 13.5 63.2 6400 76
710 AMD 500L6RH 873 993 96.6 96.6 0.86 0.84 45 239 14.2 6825 5.0 13.8 81.9 7560 76
800 AMD 500L6RH 872 994 96.7 96.6 0.86 0.83 51 290 17.0 7688 6.2 16.3 81.9 7560 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 233


HV Flameproof motors, AMD T IIB 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 511 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


800 AMD 500L2T 197 2977 95.5 95.5 0.91 0.90 88 467 17.7 2566 1.3 5.6 7.4 3880 83
900 AMD 500L2T 198 2978 95.8 95.8 0.91 0.91 99 541 19.9 2886 1.5 6.5 7.9 4080 83
1000 AMD 500L2T 368 2981 96.1 96.1 0.91 0.90 110 641 24.2 3204 1.9 7.5 8.5 4285 83
1120 AMD 560L2T 199 2980 95.9 95.9 0.91 0.91 123 635 21.5 3589 1.7 7.6 12.5 5205 83
1250 AMD 560L2T 200 2981 96.2 96.1 0.91 0.90 138 737 26.1 4004 1.9 8.7 13.2 5715 83
1400 AMD 560L2T 201 2983 96.4 96.4 0.91 0.90 154 857 29.3 4482 2.3 9.9 14.7 6020 83
1400 AMD 630M2T 895 2985 96.0 95.8 0.91 0.90 155 872 32.5 4479 1.9 10.5 22.0 7345 85
2000 AMD 630L2T 204 2985 96.5 96.4 0.91 0.91 219 1270 42.0 6398 3.1 15.5 27.8 8160 85
2150 AMD 630L2T 559 2986 96.6 96.5 0.92 0.92 233 1256 39.3 6875 2.8 15.4 32.4 8400 85
2250 AMD 710M2T 212 2987 96.0 95.6 0.92 0.93 244 1271 33.8 7193 2.4 15.7 50.7 9490 87
2500 AMD 710M2T 213 2987 96.2 95.9 0.93 0.93 270 1436 36.8 7992 2.8 17.7 53.5 9750 87
2900 AMD 710X2T 896 2988 96.1 96.0 0.93 0.92 313 1401 34.1 9297 3.1 17.7 65.5 10710 87

1500 r/min = 4 poles 6000 V 50 Hz


700 AMD 500L4T 211 1486 95.2 95.2 0.91 0.90 78 421 16.7 4498 3.1 9.5 14.7 3800 81
800 AMD 500L4T 210 1487 95.4 95.5 0.90 0.90 89 499 20.2 5138 3.7 11.2 15.6 4000 81
900 AMD 500L4T 209 1487 95.6 95.7 0.90 0.89 101 571 23.8 5780 4.3 12.9 16.7 4200 81
1120 AMD 560L4T 205 1489 95.9 96.0 0.89 0.88 126 732 33.0 7181 5.6 15.9 25.4 5815 82
1250 AMD 560L4T 206 1490 96.1 96.2 0.89 0.88 140 787 34.2 8013 5.6 17.1 27.4 6020 82
1400 AMD 560L4T 499 1489 96.2 96.4 0.91 0.91 154 858 31.2 8976 6.4 18.5 32.8 6120 82
1600 AMD 630L4T 826 1487 96.2 96.3 0.90 0.90 178 902 37.3 10275 7.1 19.9 41.2 7900 84
1800 AMD 630L4T 498 1490 96.5 96.6 0.90 0.90 199 1024 43.7 11534 6.5 22.4 45.1 8200 83
2000 AMD 630L4T 497 1491 96.7 96.7 0.90 0.88 222 1289 56.2 12809 8.1 28.4 49.4 8600 83
2240 AMD 710M4T 825 1491 96.5 96.5 0.92 0.91 244 1466 52.1 14351 9.5 33.4 83.3 9180 86

6 2500
2800
AMD 710M4T
AMD 710M4T
207
208
1491
1491
96.7
96.8
96.7
96.9
0.91
0.91
0.90
0.90
274 1516 58.0 16007 8.9 34.0 89.4
308 1704 65.6 17928 10.2 38.0 94.5
9690
10200
82
82
3150 AMD 710L4T 496 1491 96.8 96.8 0.92 0.91 341 1909 70.1 20177 10.3 45.5 94.5 11200 82
3550 AMD 710L4T 495 1490 96.9 97.0 0.92 0.91 384 2061 74.4 22745 11.3 49.2 103.3 12800 82
4000 AMD 710X4T 233 1492 97.0 97.0 0.92 0.92 431 2446 78.4 25598 12.8 56.3 141.1 13300 82
4500 AMD 710X4T 512 1493 97.2 97.2 0.92 0.92 483 2914 89.3 28782 16.4 65.5 155.8 13850 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

234 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, AMD T IIB 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 511 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


900 AMD 560L6T 214 991 95.8 96.0 0.87 0.85 105 574 31.6 8674 6.6 18.5 32.7 5815 82
1000 AMD 560L6T 500 991 95.9 96.1 0.87 0.86 115 655 33.0 9636 7.8 21.1 38.6 6120 82
1120 AMD 630L6T 827 992 95.6 95.6 0.88 0.87 128 745 35.2 10776 9.2 23.0 57.2 7245 83
1250 AMD 630L6T 215 992 96.0 96.1 0.88 0.87 142 811 39.0 12027 9.8 24.9 60.5 7450 80
1400 AMD 630L6T 507 992 95.8 95.9 0.89 0.88 158 901 38.8 13474 11.5 27.4 71.3 7855 80
1600 AMD 710M6T 828 994 96.7 96.7 0.89 0.88 178 1104 46.1 15364 11.0 35.4 116.1 9880 85
1800 AMD 710M6T 216 994 96.7 96.8 0.89 0.89 201 1061 45.0 17295 10.0 33.5 122.3 10200 79
2000 AMD 710M6T 217 994 96.8 97.0 0.90 0.89 222 1189 47.3 19217 11.6 37.3 136.1 10600 79
2250 AMD 710L6T 506 994 96.9 96.9 0.90 0.89 249 1414 56.5 21611 14.0 44.4 149.9 11000 79
2500 AMD 710L6T 508 994 96.8 97.0 0.90 0.90 277 1447 55.4 24027 14.6 45.1 144.3 11500 79
2800 AMD 710X6T 280 995 97.2 97.2 0.90 0.89 308 1873 72.2 26868 16.8 59.4 203.7 13850 79
3150 AMD 710X6T 281 995 97.2 97.2 0.91 0.90 344 2048 70.5 30242 20.1 66.1 214.5 14400 79

750 r/min = 8 poles 6000 V 50 Hz


630 AMD 560L8T 218 742 95.3 95.5 0.84 0.81 76 388 26.4 8106 6.2 15.6 35.2 5815 82
710 AMD 560L8T 501 742 95.3 95.7 0.86 0.84 83 400 24.3 9143 6.4 16.0 44.5 6120 82
800 AMD 630L8T 510 743 95.3 95.5 0.85 0.83 95 485 29.9 10276 7.7 18.5 57.7 6850 82
900 AMD 630L8T 509 743 95.6 95.7 0.85 0.83 106 518 32.4 11561 8.1 20.1 66.2 7100 82
1000 AMD 630L8T 222 744 95.8 95.9 0.85 0.83 118 606 37.1 12839 9.6 23.4 74.6 7700 82
1120 AMD 630L8T 223 743 95.8 95.9 0.86 0.85 131 652 36.9 14389 10.8 25.1 83.4 8000 82
1400 AMD 710M8T 219 744 96.4 96.5 0.87 0.86 161 851 43.5 17973 13.0 35.3 124.8 9540 74
1600 AMD 710M8T 220 744 96.5 96.6 0.87 0.86 184 974 50.5 20542 15.1 40.4 132.0 9800 74
1800 AMD 710L8T 283 744 96.6 96.8 0.87 0.87 205 978 48.0 23110 13.7 40.8 162.4 10815 74
2000 AMD 710L8T 282 745 96.8 96.9 0.88 0.87 225 1331 58.8 25638 19.9 53.8 181.4 11000 74
2250
2500
AMD 710X8T
AMD 710X8T
399
400
745
745
96.9
96.9
96.9
97.0
0.89
0.89
0.88
0.88
252
279
1433 62.8 28842 18.0 64.2 206.4
1519 64.7 32057 19.2 68.0 222.7
14100
14650
74
74
6

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 235


HV Flameproof motors, AMD T IIB 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 511 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


450 AMD 560L10T 221 594 94.6 94.6 0.77 0.72 59 305 27.5 7236 6.2 14.7 37.5 5815 82
500 AMD 560L10T 502 594 94.9 94.9 0.78 0.73 65 341 29.5 8037 6.9 16.4 44.4 6120 82
650 AMD 630M10T 279 595 95.5 95.7 0.83 0.80 79 413 29.2 10439 8.2 21.2 67.2 6800 82
730 AMD 630M10T 225 595 95.7 95.8 0.83 0.80 88 482 33.4 11720 9.7 24.7 75.8 7000 82
800 AMD 630M10T 224 594 95.5 95.9 0.85 0.84 95 421 27.9 12871 8.3 21.6 84.4 7200 82
1000 AMD 710M10T 226 595 95.9 96.1 0.85 0.83 118 612 38.0 16055 12.3 29.9 133.0 9400 74
1120 AMD 710M10T 227 595 96.0 96.1 0.85 0.82 133 695 43.1 17980 14.1 34.7 141.2 9550 74
1250 AMD 710L10T 228 595 96.0 96.2 0.85 0.83 147 758 45.6 20069 15.5 36.9 157.6 10100 74
1400 AMD 710L10T 229 595 96.1 96.3 0.85 0.83 165 855 50.9 22475 17.7 41.6 174.0 10700 74
1600 AMD 710X10T 518 595 96.4 96.5 0.86 0.85 185 983 52.1 25679 20.3 47.9 227.3 13850 74
1800 AMD 710X10T 519 595 96.4 96.6 0.86 0.85 208 1166 60.4 28877 24.8 56.5 256.9 14600 74

500 r/min = 12 poles 6000 V 50 Hz


280 AMD 560L12T 505 495 93.4 93.0 0.73 0.66 40 198 21.7 5405 5.0 11.0 34.5 5700 82
315 AMD 560L12T 504 494 93.5 93.4 0.76 0.71 43 193 20.5 6089 4.8 11.0 39.7 6000 82
355 AMD 560L12T 503 495 93.8 93.5 0.75 0.69 49 235 24.7 6855 6.0 13.3 44.8 6300 82
450 AMD 630M12T 230 494 94.2 94.3 0.78 0.74 59 249 25.2 8691 5.7 15.2 58.7 6800 82
500 AMD 630M12T 231 495 94.3 94.4 0.78 0.74 65 278 28.5 9655 6.4 16.8 63.0 7140 82
560 AMD 630M12T 232 495 94.5 94.5 0.77 0.73 74 327 33.4 10808 7.6 19.3 67.3 7755 82
630 AMD 630M12T 511 494 94.7 94.8 0.79 0.75 81 330 33.2 12167 7.4 21.1 80.2 8060 82
800 AMD 710M12T 234 495 95.5 95.7 0.84 0.81 96 474 33.8 15426 10.7 29.2 148.6 9435 74
900 AMD 710M12T 235 495 95.6 95.8 0.84 0.81 108 541 38.5 17352 12.3 33.0 157.3 9895 74
1000 AMD 710L12T 236 495 95.7 95.9 0.84 0.81 120 593 41.3 19281 13.6 36.2 174.9 10500 74
1120 AMD 710L12T 237 495 95.7 95.9 0.84 0.81 134 672 46.5 21592 15.5 40.7 178.4 10900 74

6 1250
1400
AMD 710X12T
AMD 710X12T
541
542
496
496
96.0
96.0
96.2
96.3
0.85
0.85
0.83
0.83
147 788
164 858
48.3 24083
53.0 26977
18.5 47.3 236.7 13850
19.9 51.6 256.5 14600
74
74

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

236 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, AMD T IIB 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 511 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

14 poles 6000 V 50 Hz
400 AMD 630M14T 375 422 93.4 93.5 0.74 0.68 56 229 28.1 9044 6.8 16.8 63.8 7600 82
450 AMD 630M14T 376 422 93.5 93.7 0.75 0.70 62 240 28.7 10185 7.2 17.7 72.4 7800 82
500 AMD 630M14T 377 422 93.6 93.9 0.76 0.71 68 260 30.7 11320 7.8 19.2 80.9 8000 82
560 AMD 710M14T 378 423 94.7 95.1 0.83 0.81 68 279 23.3 12641 7.2 22.0 137.2 9250 74
630 AMD 710M14T 379 423 94.7 95.1 0.83 0.81 77 305 25.6 14226 7.9 24.0 145.3 9450 74
710 AMD 710M14T 380 423 94.8 95.2 0.83 0.81 87 353 29.6 16024 9.1 27.6 161.5 10500 74
800 AMD 710L14T 543 424 95.2 95.5 0.83 0.80 98 429 35.8 18031 11.3 33.3 178.1 10900 74
900 AMD 710L14T 544 424 95.3 95.6 0.83 0.80 110 489 40.6 20281 13.0 37.8 194.4 11500 74
1000 AMD 710L14T 545 424 95.5 95.7 0.82 0.78 123 576 48.1 22518 15.4 44.2 210.7 12000 74
1120 AMD 710X14T 546 425 95.7 95.9 0.82 0.78 138 652 54.9 25169 15.6 48.8 228.5 13850 74
1250 AMD 710X14T 547 425 95.9 96.0 0.81 0.77 154 759 63.4 28078 18.3 56.6 258.6 14600 74

16 poles 6000 V 50 Hz
450 AMD 710M16T 386 371 94.6 94.9 0.77 0.73 60 231 26.0 11582 6.1 19.2 139.0 9250 74
500 AMD 710M16T 387 371 94.8 95.0 0.76 0.71 67 271 30.8 12860 7.3 22.6 147.2 9450 74
560 AMD 710M16T 388 371 95.0 95.1 0.76 0.71 75 311 35.0 14399 8.4 25.9 163.7 10500 74
710 AMD 710L16T 389 371 95.0 95.2 0.76 0.71 95 395 44.3 18255 10.8 32.8 196.5 11500 74
800 AMD 710L16T 390 371 95.1 95.3 0.77 0.72 106 447 48.0 20574 12.8 37.0 213.0 12000 74
900 AMD 710X16T 549 371 95.3 95.4 0.78 0.74 117 477 48.6 23156 13.4 39.4 238.8 13850 74
1000 AMD 710X16T 548 371 95.4 95.5 0.78 0.74 129 526 53.4 25731 14.9 43.3 258.9 14600 74

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 237


HV Flameproof motors, AMD T IIB 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 511 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 10000 V 50 Hz


615 AMD 560L2T 513 2981 94.2 94.0 0.90 0.90 42 201 8.7 1970 0.8 4.0 8.9 4795 86
690 AMD 560L2T 515 2982 94.6 94.5 0.90 0.89 47 243 10.6 2210 0.9 4.9 9.8 4900 86
775 AMD 560L2T 516 2984 95.0 94.8 0.91 0.90 52 288 11.2 2480 1.1 5.8 10.8 5000 86
875 AMD 560L2T 517 2983 95.3 95.2 0.92 0.91 58 313 11.0 2801 1.2 6.3 11.7 5100 86
975 AMD 560L2T 514 2982 95.6 95.5 0.91 0.91 64 337 12.4 3122 1.4 6.8 12.8 5205 86
1120 AMD 630M2T 521 2985 95.5 95.2 0.91 0.91 74 393 14.3 3583 1.5 8.0 20.7 7200 85
1250 AMD 630M2T 520 2985 95.7 95.5 0.92 0.92 82 454 14.8 3998 1.7 9.3 23.7 7345 85
1400 AMD 630L2T 522 2986 96.0 95.8 0.92 0.91 92 521 16.9 4478 2.1 10.7 25.2 7755 85
1600 AMD 710M2T 523 2990 95.2 94.5 0.93 0.92 105 660 18.3 5110 2.0 13.7 48.1 9490 87
1800 AMD 710M2T 524 2990 95.4 94.8 0.92 0.91 118 766 22.0 5748 2.3 15.8 50.9 9490 87
2000 AMD 710M2T 525 2990 95.7 95.1 0.93 0.92 130 844 23.1 6388 2.7 17.4 53.8 9490 87

1500 r/min = 4 poles 10000 V 50 Hz


900 AMD 560L4T 529 1492 95.4 95.2 0.88 0.86 62 386 19.3 5759 3.8 13.8 25.7 5815 82
1000 AMD 560L4T 530 1491 95.4 95.5 0.90 0.88 68 391 17.2 6403 4.0 14.0 27.5 5815 82
1090 AMD 560L4T 531 1492 95.7 95.7 0.89 0.87 74 458 20.9 6976 4.7 16.3 29.4 5815 82
1250 AMD 630L4T 532 1491 95.3 95.2 0.91 0.90 83 494 19.1 8007 5.7 17.5 43.3 7960 83
1400 AMD 630L4T 533 1492 95.6 95.6 0.91 0.90 93 559 21.5 8962 5.9 20.0 46.6 7960 83
1600 AMD 630L4T 534 1492 95.8 95.8 0.91 0.90 106 651 25.1 10242 7.1 23.2 49.7 7960 83
1800 AMD 710M4T 535 1492 96.0 95.8 0.92 0.92 117 698 22.5 11523 6.5 26.4 88.5 9690 82
2000 AMD 710M4T 536 1492 96.2 96.0 0.91 0.90 132 806 29.7 12797 7.2 29.9 92.7 9690 82
2250 AMD 710M4T 537 1492 96.3 96.3 0.92 0.92 146 896 28.5 14397 8.9 33.1 99.7 9690 82
2500 AMD 710L4T 538 1492 96.3 96.2 0.92 0.91 164 976 37.0 16005 8.6 38.8 90.0 11425 82
2800 AMD 710L4T 539 1492 96.5 96.4 0.91 0.90 184 1080 42.6 17926 9.5 42.9 94.5 11425 82

6 3000
3400
AMD 710L4T
AMD 710X4T
540
829
1491
1490
96.5
96.4
96.5
96.4
0.92
0.93
0.91
0.93
196 1138 41.4 19211 10.4 45.2 98.9
218 1192 34.0 21792 11.4 47.8 139.2 13600
11425 82
86
3600 AMD 710X4T 831 1491 96.6 96.5 0.93 0.93 232 1408 42.7 23058 13.8 56.4 145.4 13600 86
3700 AMD 710X4T 830 1490 96.6 96.6 0.93 0.93 237 1361 37.4 23708 13.4 54.4 151.6 13600 86

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

238 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, AMD T IIB 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 511 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 10000 V 50 Hz


450 AMD 560L6T 238 991 94.1 94.2 0.86 0.83 32 171 11.1 4334 2.8 8.7 23.9 4600 83
500 AMD 560L6T 239 991 94.4 94.5 0.86 0.84 35 186 11.4 4817 3.1 9.4 26.1 4800 83
560 AMD 560L6T 240 991 94.7 94.9 0.87 0.84 39 207 12.3 5395 3.6 10.6 28.3 5100 83
630 AMD 560L6T 241 991 94.9 95.1 0.87 0.85 44 236 13.7 6069 4.1 12.1 35.6 5400 83
710 AMD 560L6T 242 992 95.2 95.3 0.86 0.84 50 277 16.0 6838 5.0 14.2 38.2 5700 83
800 AMD 560L6T 733 993 95.4 95.5 0.86 0.83 56 341 18.9 7695 6.4 17.5 41.0 6000 83
900 AMD 630L6T 243 992 95.1 95.2 0.89 0.87 62 338 16.6 8662 6.7 17.5 62.5 7245 80
1000 AMD 630L6T 244 992 95.3 95.4 0.89 0.87 68 377 18.2 9625 7.6 19.5 66.8 7450 80
1120 AMD 630L6T 732 993 95.6 95.7 0.88 0.87 77 444 21.3 10772 8.7 22.6 74.9 7900 80
1250 AMD 710M6T 782 994 96.0 96.0 0.89 0.89 84 408 18.4 12015 5.9 21.5 109.3 9000 79
1400 AMD 710M6T 783 994 96.2 96.2 0.89 0.89 94 473 21.2 13454 7.0 24.9 116.8 9350 79
1600 AMD 710M6T 784 994 96.3 96.4 0.90 0.89 107 529 22.2 15378 8.0 27.7 131.8 10460 79
1800 AMD 710L6T 785 994 96.5 96.6 0.89 0.89 121 588 25.4 17298 9.1 29.9 137.1 11000 79
2000 AMD 710L6T 786 994 96.5 96.7 0.89 0.89 134 648 28.2 19223 10.2 33.6 143.4 11500 79

750 r/min = 8 poles 10000 V 50 Hz


630 AMD 630L8T 245 744 94.6 94.9 0.85 0.82 45 231 15.2 8086 5.6 14.7 57.9 6990 82
710 AMD 630L8T 246 744 94.8 95.1 0.85 0.83 51 265 16.8 9111 6.5 16.8 66.4 7245 82
800 AMD 630L8T 247 744 94.9 95.2 0.85 0.83 57 291 18.3 10268 7.2 18.4 70.7 7650 82
1000 AMD 710M8T 262 744 95.8 95.9 0.87 0.85 69 381 20.1 12828 9.1 26.2 109.9 9285 74
1120 AMD 710M8T 263 744 95.9 96.1 0.87 0.86 77 406 20.6 14373 9.8 27.1 124.3 9540 74
1250 AMD 710M8T 264 744 96.1 96.2 0.87 0.86 86 473 23.8 16036 11.7 32.4 131.6 10000 74
1400 AMD 710M8T 265 745 96.3 96.4 0.87 0.85 96 566 28.6 17953 14.3 38.8 138.8 10815 74
1600 AMD 710L8T 266 743 96.0 96.3 0.87 0.87 110 534 26.2 20551 13.4 36.5 133.3 11120 74
1800
2000
AMD 710L8T
AMD 710L8T
267
268
743
744
96.1
96.3
96.4
96.6
0.88
0.88
0.87
0.87
123 595
137 733
28.4
34.8
23120 15.1 39.5 153.0
25666 19.1 49.8 166.1
11530
11935
74
74
6

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 239


HV Flameproof motors, AMD T IIB 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 511 - Insulation class F, temperature rise class B

Efciency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 10000 V 50 Hz


450 AMD 630M10T 248 596 94.0 94.0 0.80 0.75 34 210 16.4 7212 6.4 17.4 58.6 6940 82
500 AMD 630M10T 249 596 94.2 94.3 0.81 0.76 38 226 17.3 8016 7.0 18.7 62.9 7040 82
560 AMD 630M10T 250 595 94.0 94.4 0.84 0.81 41 208 15.4 8992 6.4 17.4 67.2 7140 82
710 AMD 710M10T 269 594 94.9 95.2 0.84 0.83 51 229 15.3 11412 7.1 18.2 114.8 8980 74
800 AMD 710M10T 270 594 95.1 95.4 0.84 0.83 58 254 16.7 12861 7.9 20.0 123.0 9285 74
900 AMD 710M10T 271 594 95.2 95.6 0.84 0.83 65 288 18.8 14468 9.1 22.4 131.2 9590 74
1000 AMD 710M10T 272 595 95.4 95.7 0.84 0.83 72 348 22.2 16061 11.3 27.7 147.6 9895 74
1120 AMD 710L10T 273 595 95.5 95.7 0.84 0.83 80 391 24.5 17987 12.8 31.0 151.3 10710 74
1250 AMD 710L10T 274 594 95.6 95.9 0.85 0.84 89 410 25.2 20086 13.5 32.2 166.4 11120 74
1400 AMD 710L10T 275 595 95.8 96.1 0.85 0.83 100 478 28.9 22485 15.9 37.4 189.0 11730 74

500 r/min = 12 poles 10000 V 50 Hz


315 AMD 630M12T 251 493 91.1 91.9 0.80 0.78 25 88 9.3 6097 3.2 9.0 54.4 6735 82
355 AMD 630M12T 252 493 91.5 92.3 0.80 0.78 28 98 10.1 6873 3.6 10.1 58.7 6940 82
400 AMD 630M12T 253 493 92.2 92.9 0.80 0.78 31 114 11.5 7742 4.3 11.7 63.0 7140 82
450 AMD 630M12T 254 494 92.4 93.0 0.80 0.77 35 130 13.3 8706 4.9 13.4 67.3 7755 82
560 AMD 710M12T 276 494 94.3 94.7 0.84 0.81 41 175 13.6 10825 6.0 18.7 122.4 8365 74
630 AMD 710M12T 277 494 94.4 94.9 0.84 0.82 46 195 15.0 12181 6.7 20.8 130.6 8775 74
710 AMD 710M12T 278 494 94.6 95.0 0.84 0.82 52 221 16.9 13727 7.7 23.6 138.8 9435 74
800 AMD 710M12T 284 494 94.7 95.2 0.84 0.82 58 241 18.0 15472 8.5 25.8 155.2 9845 74
900 AMD 710L12T 285 494 94.8 95.2 0.84 0.82 66 288 21.6 17394 10.3 29.3 150.7 10710 74
1000 AMD 710L12T 286 494 95.0 95.4 0.84 0.82 72 318 23.3 19324 11.4 32.5 173.3 11220 74
1120 AMD 710L12T 287 494 95.3 95.6 0.84 0.82 81 372 27.0 21630 13.5 37.9 195.9 12240 74

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

240 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, AMD T IIB 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 511 - Insulation class F, temperature rise class B
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

14 poles 10000 V 50 Hz
500 AMD 710M14T 369 424 94.3 94.5 0.78 0.74 39 167 16.7 11250 6.6 20.2 129.6 8600 74
560 AMD 710M14T 370 424 94.3 94.6 0.79 0.75 43 179 17.6 12607 7.0 21.6 137.8 9250 74
630 AMD 710M14T 371 424 94.7 94.9 0.79 0.75 49 211 20.6 14174 8.4 25.4 154.3 9650 74
710 AMD 710L14T 372 425 94.9 95.0 0.77 0.73 56 251 25.2 15964 10.2 30.1 178.6 10900 74
800 AMD 710L14T 373 425 95.1 95.2 0.78 0.74 62 282 27.2 17991 11.7 33.5 195.0 11500 74
900 AMD 710L14T 374 425 95.2 95.3 0.78 0.74 70 307 29.9 20241 12.5 36.8 211.3 12000 74

16 poles 10000 V 50 Hz
450 AMD 710M16T 381 371 93.9 94.0 0.76 0.71 36 152 17.1 11568 6.7 20.8 155.4 9650 74
500 AMD 710M16T 382 371 94.0 94.1 0.76 0.72 40 166 18.7 12856 7.4 22.8 163.7 10500 74
560 AMD 710L16T 383 371 94.1 94.4 0.77 0.73 45 176 19.5 14407 7.8 24.2 180.1 10900 74
630 AMD 710L16T 384 371 94.2 94.5 0.78 0.74 50 190 20.8 16215 8.5 26.2 196.5 11500 74
710 AMD 710L16T 385 371 94.3 94.7 0.78 0.74 56 209 22.9 18279 9.4 28.9 213.0 12000 74

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 241


HV Flameproof motors, Ex d/(de) IIB T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 1001 (IM B3), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y


Hz

355 L 2 50-60 610 900 630 80 254 70 140 20 62.5 355 35 1765 2215 470 258 200 450
355 L 4-6 50-60 610 900 630 80 280 100 210 28 90 355 35 1860 2310 470 284 200 450

AMD Rg Poles Frequency Z Z1 Z2 AA AB AC AC1 AD AD1 BA BB GD HA D-end N-end


Hz bearing bearing

6 355 L
355 L
2
4-6
50-60
50-60
1236 20
1236 20
35
35
120
120
700
700
725
725
610
610
1430 740
1430 740
445 1078 12
445 1078 16
45
45
6316
6322
6316
6316

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

242 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d/(de) IIB T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 6.6 kV, IM 1001 (IM B3), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y Z


Hz

400 L 2 50-60 710 1120 900 100 224 80 170 22 71 400 35 2011 2461 360 308 200 450 1334
400 L 4-8 50-60 710 1120 900 100 224 110 210 28 100 400 35 2051 2501 360 308 200 450 1334

AMD Rg Poles Frequency Z1 Z2 AA AB AC AC1 AD AD1 AD2 AD3 AD4 BA BB GD HA D-end N-end
Hz bearing bearing

400 L
400 L
2
4-8
50-60
50-60
-
-
-
-
150 840
150 840
814 610
814 610
1518 630
1518 630
828
828
405
405
280
280
390 1296 14
390 1296 16
45
45
6317
6324
6317
6319 6

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 243


HV Flameproof motors, Ex d/(de) IIB T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 11 kV, IM 1001 (IM B3), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y Z


Hz

400 L 2 50-60 710 1120 900 100 224 80 170 22 71 400 35 2011 2461 470 308 200 450 1334
400 L 4-8 50-60 710 1120 900 100 224 110 210 28 100 400 35 2051 2501 470 308 200 450 1334

AMD Rg Poles Frequency Z1 Z2 AA AB AC AC1 AD AD1 AD2 AD3 AD4 BA BB GD HA D-end N-end
Hz bearing bearing

6 400 L
400 L
2
4-8
50-60
50-60
-
-
-
-
150
150
840 814 610
840 814 610
1536 630
1536 630
828
828
625
625
280
280
390 1296 14
390 1296 16
45
45
6317
6324
6317
6319

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

244 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d/(de) IIC T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 6.6 kV, IM 1001 (IM B3), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y Z


Hz

400 L 2 50-60 710 1120 900 100 224 80 170 22 71 400 35 2011 2461 360 308 200 450 1334
400 L 4-8 50-60 710 1120 900 100 224 110 210 28 100 400 35 2051 2501 360 308 200 450 1334

AMD Rg Poles Frequency Z1 Z2 AA AB AC AC1 AD AD1 AD2 AD3 AD4 BA BB GD HA D-end N-end
Hz bearing bearing

400 L
400 L
2
4-8
50-60
50-60
-
-
-
-
150 840
150 840
814 610
814 610
1518 630
1518 630
828
828
405
405
280
280
390 1296 14
390 1296 16
45
45
6317
6324
6317
6319
6

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 245


HV Flameproof motors, Ex d/(de) IIC T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 11 kV, IM 1001 (IM B3), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y Z


Hz

400 L 2 50-60 710 1120 900 100 224 80 170 22 71 400 35 2011 2461 525 308 200 450 1334
400 L 4-8 50-60 710 1120 900 100 224 110 210 28 100 400 35 2051 2501 525 308 200 450 1334

AMD Rg Poles Frequency Z1 Z2 AA AB AC AC1 AD AD1 AD2 AD3 AD4 BA BB GD HA D-end N-end
Hz bearing bearing

6 400 L
400 L
2
4-8
50-60
50-60
-
-
-
-
150
150
840
840
814 610
814 610
1536 630
1536 630
828
828
625
625
280
280
390 1296 14
390 1296 16
45
45
6317
6324
6317
6319

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

246 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d IIB T4, AMD Rg (IEC)
Dimension drawings
Sleeve bearings, 6.6 < UN 11 kV, IM 1001 (IM B3), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y


Hz

355 L 2 50-60 610 900 630 80 375 80 170 22 71 355 35 1955 2405 470 379 200 450
355 L 4 50-60 610 900 630 80 375 90 170 25 81 355 35 2065 2515 470 379 200 450

AMD Rg Poles Frequency Z Z1 Z2 AA AB AC AC1 AD AD1 BA BB GD HA D-end N-end


Hz bearing bearing

355 L
355 L
2
4
50-60
50-60
1238 20
1238 20
35
35
120
120
700
700
725
725
610
610
1440 740
1440 740
445
445
1078
1078
14
14
45
45
EFNLB 9-80
EFNLB 9-90
EFNLQ 9-80
EFNLQ 9-80 6

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 247


HV Flameproof motors, Ex d/(de) IIB T4, AMD Rg (IEC)
Dimension drawings
Sleeve bearings, 6.6 < UN 11 kV, IM 1001 (IM B3), IC01 / IC411

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y Z Z1


Hz

400 L 2 50-60 710 1120 900 100 335 80 170 22 71 400 35 2130 2580 470 419 200 450 1332 -
400 L 4-8 50-60 710 1120 900 100 375 110 210 28 100 400 35 2360 2810 470 459 200 450 1332 -

AMD Rg Poles Frequency Z2 AA AB AC AC1 AD AD1 AD2 AD3 AD4 BA BB GD HA D-end bearing N-end
Hz bearing

6 400 L
400 L
2
4-8
50-60
50-60
-
-
150 840 814 610
150 840 814 610
1533 628
1533 628
828
828
405
405
280
280
390 1296 14
390 1296 16
45
45
EFNLB 9-80 EFNLQ 9-80
EFNLB 11-125 EFNLQ 9-100

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

248 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d/(de) IIC T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 6.6 kV, IM 1001 (IM B3), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y Z


Hz

355 L 2 50-60 610 900 630 80 254 70 140 20 62.5 355 35 1765 2215 360 258 200 450 1191
355 L 4-6 50-60 610 900 630 80 280 100 210 28 90 355 35 1860 2310 360 284 200 450 1191

AMD Rg Poles Frequency Z1 Z2 AA AB AC AC1 AD AD1 AD2 AD3 AD4 BA BB GD HA D-end N-end
Hz bearing bearing

355 L
355 L
2
4-6
50-60
50-60
20
20
35
35
120
120
700
700
725 610
725 610
1346 740
1346 740
405
405
510
510
600
600
445 1078 12
445 1078 16
45
45
6316
6322
6316
6316
6

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 249


HV Flameproof motors, Ex d/(de) IIC T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 11 kV, IM 1001 (IM B3), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency A B B1 B2 C D E F G H K L L1 U V X Y Z


Hz

355 L 2 50-60 610 900 630 80 254 70 140 20 62.5 355 35 1765 2215 525 258 200 450 1248
355 L 4-6 50-60 610 900 630 80 280 100 210 28 90 355 35 1860 2310 525 284 200 450 1248

AMD Rg Poles Frequency Z1 Z2 AA AB AC AC1 AD AD1 AD2 AD3 AD4 BA BB GD HA D-end N-end
Hz bearing bearing

6 355 L
355 L
2
4-6
50-60
50-60
20
20
35
35
120
120
700
700
725
725
610
610
1450 740
1450 740
642
642
510
510
600
600
445 1078 12
445 1078 16
45
45
6316
6322
6316
6316

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

250 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d/(de) IIB T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 6.6 kV, IM 3011 (IM V1), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency D E F G M N L P S U V


Hz

355 L 2 50-60 70 140 20 62.5 740 680 1875 800 23 470 258
355 L 4-8 50-60 100 210 28 90 740 680 1970 800 23 470 258

AMD Rg Poles Frequency Z AC AC1 AD LA GD N holes a D-end N-end


Hz equid. bearing bearing

355 L
355 L
2
4-8
50-60
50-60
881
881
740
740
1100
1100
1075
1075
26
26
12
16
8
8
22.5
22.5
6316
6322
7213
6316
6

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 251


HV Flameproof motors, Ex d/(de) IIB T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 6.6 kV, IM 3011 (IM V1), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency D E F G M N L P S U V Z AC AC1


Hz

400 L 2 50-60 80 170 22 71 940 880 2180 1000 28 360 310 935 830 1100
400 L 4-8 50-60 110 210 28 100 940 880 2220 1000 28 360 310 935 830 1100

AMD Rg Poles Frequency AD AD1 AD2 AD3 AD4 LA GD N holes a D-end N-end
Hz equid. bearing bearing

6 400 L
400 L
2
4-8
50-60
50-60
1120
1120
650
650
560
560
405
405
280
280
-
-
14
16
8
8
22.5
22.5
6217
6324
7217
6319

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

252 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d/(de) IIB T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 11 kV, IM 3011 (IM V1), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency D E F G M N L P S U V Z AC


Hz

400 L 2 50-60 80 170 22 71 940 880 2180 1000 28 470 310 935 830
400 L 4-8 50-60 110 210 28 100 940 880 2220 1000 28 470 310 935 830

AMD Rg Poles Frequency AC1 AD AD1 AD2 AD3 AD4 LA GD N holes a D-end N-end
Hz equid. bearing bearing

400 L
400 L
2
4-8
50-60
50-60
1100
1100
1120
1120
650
650
560
560
625
625
280
280
-
-
14
16
8
8
22.5
22.5
6217
6324
7217
6319
6

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 253


HV Flameproof motors, Ex d/(de) IIC T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 6.6 kV, IM 3011 (IM V1), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency D E F G M N L P S U V Z AC


Hz

400 L 2 50-60 80 170 22 71 940 880 2180 1000 28 360 310 935 830
400 L 4-8 50-60 110 210 28 100 940 880 2220 1000 28 360 310 935 830

AMD Rg Poles Frequency AC1 AD AD1 AD2 AD3 AD4 LA GD N holes a D-end N-end
Hz equid. bearing bearing

6 400 L
400 L
2
4-8
50-60
50-60
1100
1100
1140
1140
650
650
560
560
405
405
280
280
-
-
14
16
8
8
22.5
22.5
6217
6324
7217
6319

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

254 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d/(de) IIC T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, UN = 11 kV, IM 3011 (IM V1), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency D E F G M N L P S U V Z AC


Hz

400 L 2 50-60 80 170 22 71 940 880 2180 1000 28 525 310 935 830
400 L 4-8 50-60 110 210 28 100 940 880 2220 1000 28 525 310 935 830

AMD Rg Poles Frequency AC1 AD AD1 AD2 AD3 AD4 LA GD N holes a D-end N-end
Hz equid. bearing bearing

400 L
400 L
2
4-8
50-60
50-60
1100
1100
1140
1140
650
650
560
560
625
625
280
280
-
-
14
16
8
8
22.5
22.5
6217
6324
7217
6319
6

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 255


HV Flameproof motors, Ex d/(de) IIC T4, AMD Rg (IEC)
Dimension drawings
Antifriction bearings, 6.6 < UN 11 kV, IM 3011 (IM V1), IC01 / IC411, cast iron frame

AMD Rg Poles Frequency D E F G M N L P S U V


Hz

355 L 2 50-60 70 140 20 62.5 740 680 1875 800 23 360 258
355 L 4-6 50-60 100 210 28 90 740 680 1970 800 23 360 284

AMD Rg Poles Frequency Z AC AC1 AD LA GD N holes a D-end N-end


Hz equid. bearing bearing

6
355 L 2 50-60 715 740 900 870 26 12 8 22.5 6316 7213
355 L 4-6 50-60 715 740 900 870 26 16 8 22.5 6322 6316

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

256 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d IIB T4, AMD R (IEC)
Dimension drawings
Antifriction bearings, UN 11 kV, IM 1001 (IM B3), IC01 / IC411

AMD Poles Frequency A B C D E F G H K L U V V1 X Z


Hz

450 M 4 50 - 60 800 900 315 110 210 28 100 450 42 2055 470 325 875 180 1449
450 M 6 - 10 50 - 60 800 900 315 110 210 28 100 450 42 2055 470 325 875 180 1449
450 L 2 50 - 60 800 1120 315 80 170 22 71 450 42 2085 470 355 1035 180 1449
450 L 4 50 - 60 800 1120 315 110 210 28 100 450 42 2245 470 355 1035 180 1449
450 L 6 - 10 50 - 60 800 1120 315 110 210 28 100 450 42 2245 470 355 1035 180 1449
500 M 4 50 - 60 850 1120 315 120 210 32 109 500 42 2310 470 355 1035 200 1544
500 M
500 L
500 L
6 - 12
2
4
50 - 60
50
50 - 60
850
850
850
1120
1250
1250
315
375
375
120
90
120
210
170
210
32
25
32
109
81
109
500
500
500
42
42
42
2310
2390
2575
470
470
470
355
360
360
1035
1295
1295
200
200
200
1544
1544
1544
6
500 L 6 - 12 50 - 60 850 1250 375 120 210 32 109 500 42 2575 470 360 1295 200 1544

AMD Poles Frequency Z2 Z3 AA AB AC AC1 AD BB BD GD HA D-end N-end


Hz bearing bearing

450 M 4 50 - 60 990 80 225 950 469.5 446 1645 1170 180 16 30 6324 6321
450 M 6 - 10 50 - 60 990 80 225 950 469.5 446 1645 1170 180 16 30 6324 6321
450 L 2 50 - 60 990 80 225 950 469.5 446 1645 1360 195 14 30 6317 NU215
450 L 4 50 - 60 990 80 225 950 469.5 446 1645 1360 195 16 30 6324 6321
450 L 6 - 10 50 - 60 990 80 225 950 469.5 446 1645 1360 195 16 30 6324 6321
500 M 4 50 - 60 1085 80 225 1020 521.5 496 1740 1360 195 18 30 6326 6324
500 M 6 - 12 50 - 60 1085 80 225 1020 521.5 496 1740 1360 195 18 30 6326 6324
500 L 2 50 1085 100 225 1020 521.5 496 1740 1610 205 14 30 6319 NU217
500 L 4 50 - 60 1085 100 225 1020 521.5 496 1740 1610 205 18 30 6326 6324
500 L 6 - 12 50 - 60 1085 100 225 1020 521.5 496 1740 1610 205 18 30 6326 6324

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 257


HV Flameproof motors, Ex d IIB T4, AMD R (NEMA)
Dimension drawings
Antifriction bearings, 1 < UN 7.2 kV, F3, TEFC, steel welded frame

AMD Poles Frequency A B C D G H J O R S U X Z


Hz

450 M 4 60 37.4 46 76.5 18 1.2 1.65 8.9 65 3.817 1 (+0.003 / 0) 4.375 7 57.3
450 M 6 60 37.4 46 81 18 1.2 1.65 8.9 65 3.817 1 (+0.003 / 0) 4.375 7 57.3
450 L 2 60 37.4 53.5 81 18 1.2 1.65 8.9 65 2.704 0.75 (+0.002 / 0) 3.125 7 57.3
450 L 4 60 37.4 53.5 84 18 1.2 1.65 8.9 65 3.817 1 (+0.003 / 0) 4.375 7 57.3
450 L 6 60 37.4 53.5 88.5 18 1.2 1.65 8.9 65 3.817 1 (+0.003 / 0) 4.375 7 57.3
500 M 4 60 41.5 53.5 85.5 20 1.2 1.65 8.9 68.8 4.041 1,25 (+0.003 / 0) 4.75 8 61.1

6 500 M
500 L
500 L
6
4
6
60
60
60
41.5
41.5
41.5
53.5
63.25
63.25
91
96
101.5
20
20
20
1.2
1.2
1.2
1.65
1.65
1.65
8.9
8.9
8.9
68.8
68.8
68.8
4.041
4.041
4.041
1,25 (+0.003 / 0)
1,25 (+0.003 / 0)
1,25 (+0.003 / 0)
4.75
4.75
4.75
8
8
8
61.1
61.1
61.1

AMD Poles Frequency 2E 2F AF BA BS DJ FDS FDS1 N-W D-end N-end


Hz bearing bearing

450 M 4 60 32 36 18.5 11.5 1.5 39.3 35.7 5.3 8.25 6324 6321
450 M 6 60 32 36 18.5 11.5 1.5 39.3 35.7 5.3 8.25 6324 6321
450 L 2 60 32 45 18.5 11.5 2.5 39.3 42 5.3 6.5 6317 NU215
450 L 4 60 32 45 18.5 11.5 2.5 39.3 42 5.3 8.25 6324 6321
450 L 6 60 32 45 18.5 11.5 2.5 39.3 42 5.3 8.25 6324 6321
500 M 4 60 35 45 18.5 11.5 2.5 43 42 5.3 8.25 6326 6324
500 M 6 60 35 45 18.5 11.5 2.5 43 42 5.3 8.25 6326 6324
500 L 4 60 35 50 18.5 16 -2 43 52 5.3 8.25 6326 6324
500 L 6 60 35 50 18.5 16 -2 43 52 5.3 8.25 6326 6324

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

258 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d IIC T4, AMD R (IEC)
Dimension drawings
Antifriction bearings, UN = 6.6 kV, IM 1001 (IM B3), IC01 / IC411, steel welded frame

AMD Poles Frequency A B C D E F G H K L U V V1 X Z


Hz

450 M 4 50 - 60 800 900 315 110 210 28 100 450 42 2055 360 345 845 180 1431
450 M 6 - 10 50 - 60 800 900 315 110 210 28 100 450 42 2055 360 345 845 180 1431
450 L 2 50 800 1120 315 80 170 22 71 450 42 2085 360 375 990 180 1431
450 L 4 50 - 60 800 1120 315 110 210 28 100 450 42 2245 360 375 990 180 1431
450 L 6 - 10 50 - 60 800 1120 315 110 210 28 100 450 42 2245 360 375 990 180 1431
500 M 2 50 850 1120 315 90 170 25 81 500 42 2130 360 375 990 200 1524
500 M
500 M
500 L
4
6 - 12
2
50 - 60
50 - 60
50
850
850
850
1120
1120
1250
315
315
375
120
120
90
210
210
170
32
32
25
109
109
81
500
500
500
42
42
42
2310
2310
2390
360
360
360
375
375
380
990
990
1250
200
200
200
1524
1524
1524
6
500 L 4 50 - 60 850 1250 375 120 210 32 109 500 42 2575 360 380 1250 200 1524
500 L 6 - 12 50 - 60 850 1250 375 120 210 32 109 500 42 2575 360 380 1250 200 1524

AMD Poles Frequency Z2 Z3 AA AB AC AC1 AD BB BD GD HA D-end N-end


Hz bearing bearing

450 M 4 50 - 60 993 80 225 950 469.5 446 1609 1170 180 16 30 6324 6321
450 M 6 - 10 50 - 60 993 80 225 950 469.5 446 1609 1170 180 16 30 6324 6321
450 L 2 50 993 80 225 950 469.5 446 1609 1350 200 14 30 6317 NU215
450 L 4 50 - 60 993 80 225 950 469.5 446 1609 1350 200 16 30 6324 6321
450 L 6 - 10 50 - 60 993 80 225 950 469.5 446 1609 1350 200 16 30 6324 6321
500 M 2 50 1088 80 225 1020 521.5 496 1702 1350 200 14 30 6319 NU217
500 M 4 50 - 60 1088 80 225 1020 521.5 496 1702 1350 200 18 30 6326 6324
500 M 6 - 12 50 - 60 1088 80 225 1020 521.5 496 1702 1350 200 18 30 6326 6324
500 L 2 50 1088 100 225 1020 521.5 496 1702 1610 205 14 30 6319 NU217
500 L 4 50 - 60 1088 100 225 1020 521.5 496 1702 1610 205 18 30 6326 6324

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 259


HV Flameproof motors, Ex d IIC T4, AMD R (IEC)
Dimension drawings
Antifriction bearings, UN = 11 kV, IM 1001 (IM B3), IC01 / IC411, steel welded frame

AMD Poles Frequency A B C D E F G H K L U V V1 X Z


Hz

450 M 4 50 - 60 800 900 315 110 210 28 100 450 42 2055 525 345 845 180 1488
450 M 6 - 10 50 - 60 800 900 315 110 210 28 100 450 42 2055 525 345 845 180 1488
450 L 2 50 800 1120 315 80 170 22 71 450 42 2085 525 375 990 180 1488
450 L 4 50 - 60 800 1120 315 110 210 28 100 450 42 2245 525 375 990 180 1488
450 L 6 - 10 50 - 60 800 1120 315 110 210 28 100 450 42 2245 525 375 990 180 1488
500 M 2 50 850 1120 315 90 170 25 81 500 42 2130 525 375 990 200 1581

6 500 M
500 M
500 L
4
6 - 12
2
50 - 60
50 - 60
50
850
850
850
1120
1120
1250
315
315
375
120
120
90
210
210
170
32
32
25
109
109
81
500
500
500
42
42
42
2310
2310
2390
525
525
525
375
375
380
990
990
1250
200
200
200
1581
1581
1581
500 L 4 50 - 60 850 1250 375 120 210 32 109 500 42 2575 525 380 1250 200 1581
500 L 6 - 12 50 - 60 850 1250 375 120 210 32 109 500 42 2575 525 380 1250 200 1581

AMD Poles Frequency Z2 Z3 AA AB AC AC1 AD BB BD GD HA D-end N-end


Hz bearing bearing

450 M 4 50 - 60 993 80 225 950 469.5 446 1713 1170 180 16 30 6324 6321
450 M 6 - 10 50 - 60 993 80 225 950 469.5 446 1713 1170 180 16 30 6324 6321
450 L 2 50 993 80 225 950 469.5 446 1713 1350 200 14 30 6317 NU215
450 L 4 50 - 60 993 80 225 950 469.5 446 1713 1350 200 16 30 6324 6321
450 L 6 - 10 50 - 60 993 80 225 950 469.5 446 1713 1350 200 16 30 6324 6321
500 M 2 50 1088 80 225 1020 521.5 496 1806 1350 200 14 30 6319 NU217
500 M 4 50 - 60 1088 80 225 1020 521.5 496 1806 1350 200 18 30 6326 6324
500 M 6 - 12 50 - 60 1088 80 225 1020 521.5 496 1806 1350 200 18 30 6326 6324
500 L 2 50 1088 100 225 1020 521.5 496 1806 1610 205 14 30 6319 NU217
500 L 4 50 - 60 1088 100 225 1020 521.5 496 1806 1610 205 18 30 6326 6324

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

260 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d IIB T4, AMD R (IEC)
Dimension drawings
Antifriction bearings, UN 11 kV, IM 1001 (IM B3), IC416, steel welded frame

AMD Poles Frequency A B C D E F G H K L L tot. L2 U V V1 X


Hz

450 M 4 800 900 315 110 210 28 100 450 42 2055 2515 460 470 325 875 180
450 M 6 - 10 800 900 315 110 210 28 100 450 42 2055 2515 460 470 325 875 180
450 L 2 800 1120 315 70 140 20 62.5 450 42 2055 2515 460 470 355 1035 180
450 L 4 800 1120 315 110 210 28 100 450 42 2245 2705 460 470 355 1035 180
450 L 6 - 10 800 1120 315 110 210 28 100 450 42 2245 2705 460 470 355 1035 180
500 M 4 850 1120 315 120 210 32 109 500 42 2310 2820 510 470 355 1035 200
500 M
500 L
500 L
6 - 12
4
6 - 12
850
850
850
1120
1250
1250
315
375
375
120
120
120
210
210
210
32
32
32
109
109
109
500
500
500
42
42
42
2310
2575
2575
2820
3085
3085
510
510
510
470
470
470
355
360
360
1035
1295
1295
200
200
200
6
AMD Poles Frequency Z Z2 Z3 AA AB AC AC1 AD BB BD GD HA D-end N-end
Hz bearing bearing

450 M 4 1449 990 80 225 950 469.5 446 1645 1170 180 16 30 6324 6321
450 M 6 - 10 1449 990 80 225 950 469.5 446 1645 1170 180 16 30 6324 6321
450 L 2 1449 990 80 225 950 469.5 446 1645 1360 195 12 30 6317 NU215
450 L 4 1449 990 80 225 950 469.5 446 1645 1360 195 16 30 6324 6321
450 L 6 - 10 1449 990 80 225 950 469.5 446 1645 1360 195 16 30 6324 6321
500 M 4 1544 1085 80 225 1020 521.5 496 1740 1360 195 18 30 6326 6324
500 M 6 - 12 1544 1085 80 225 1020 521.5 496 1740 1360 195 18 30 6326 6324
500 L 4 1544 1085 100 225 1020 521.5 496 1740 1610 205 18 30 6326 6324
500 L 6 - 12 1544 1085 100 225 1020 521.5 496 1740 1610 205 18 30 6326 6324

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 261


HV Flameproof motors, Ex d IIB T4, AMD R (IEC)
Dimension drawings
Sleeve bearings, UN = 11 kV, IM 1001 (IM B3), IC01 / IC411, steel welded frame

AMD Poles Frequency A B C D E F G H K L U V V1 X Z Z2


Hz

450 M 4 50 - 60 800 900 530 110 210 28 100 450 42 2400 470 540 875 180 1449 990
450 M 6 - 10 50 - 60 800 900 530 110 210 28 100 450 42 2450 470 540 875 180 1449 990
450 L 2 50 - 60 800 1120 450 80 170 22 71 450 42 2370 470 490 1035 180 1449 990
450 L 4 50 - 60 800 1120 500 110 210 28 100 450 42 2560 470 540 1035 180 1449 990
450 L 6 - 10 50 - 60 800 1120 500 110 210 28 100 450 42 2610 470 540 1035 180 1449 990
500 M 4 50 - 60 850 1120 500 125 210 32 114 500 42 2600 470 540 1035 200 1544 1085

6 500 M
500 L
500 L
6 - 12
2
4
50 - 60
50
50 - 60
850
850
850
1120
1250
1250
500
500
560
125
90
125
210
170
210
32
25
32
114
81
114
500
500
500
42
42
42
2600
2645
2865
470
470
470
540
485
545
1035
1295
1295
200
200
200
1544
1544
1544
1085
1085
1085
500 L 6 - 12 50 - 60 850 1250 560 125 210 32 114 500 42 2865 470 545 1295 200 1544 1085

AMD Poles Frequency Z3 Z4 Z5 AA AB AC AC1 AD BB BD GD HA D-end bearing N-end bearing


Hz

450 M 4 50 - 60 80 610 70 225 950 469.5 446 1645 1170 395 16 30 EFNLB 11-125 EFNLQ 9-100
450 M 6 - 10 50 - 60 80 610 70 225 950 469.5 446 1645 1170 395 16 30 EFNLB 11-125 EFNLQ 9-100
450 L 2 50 - 60 80 610 60 225 950 469.5 446 1645 1360 330 14 30 EFNLB 9-80 EFNLQ 9-80
450 L 4 50 - 60 80 610 70 225 950 469.5 446 1645 1360 380 16 30 EFNLB 11-125 EFNLQ 9-100
450 L 6 - 10 50 - 60 80 610 70 225 950 469.5 446 1645 1360 380 16 30 EFNLB 11-125 EFNLQ 9-100
500 M 4 50 - 60 80 660 85 225 1020 521.5 496 1740 1360 380 18 30 EFNLB 14-125 EFNLQ 9-100
500 M 6 - 12 50 - 60 80 660 85 225 1020 521.5 496 1740 1360 380 18 30 EFNLB 14-125 EFNLQ 9-100
500 L 2 50 100 660 60 225 1020 521.5 496 1740 1610 330 14 30 EFNLB 9-90 EFNLQ 9-90
500 L 4 50 - 60 100 660 60 225 1020 521.5 496 1740 1610 390 18 30 EFNLB 14-125 EFNLQ 9-100
500 L 6 - 12 50 - 60 100 660 60 225 1020 521.5 496 1740 1610 390 18 30 EFNLB 14-125 EFNLQ 9-100

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

262 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d IIB T4, AMD R (NEMA)
Dimension drawings
Sleeve bearings, 1 < UN 7.2 kV, F3, TEFC, steel welded frame

AMD Poles Frequency A B C D G H J O R S U X Z Z4


Hz

450 M 4 60 37.4 46 90.75 18 1.2 1.65 8.9 65 3.817 1 (+0.003 / 0) 4.375 7 57.3 24
450 M 6 60 37.4 46 96.5 18 1.2 1.65 8.9 65 3.817 1 (+0.003 / 0) 4.375 7 57.3 24
450 L 2 60 37.4 53.5 93.5 18 1.2 1.65 8.9 65 2.704 0.75 (+0.002 / 0) 3.125 7 57.3 24
450 L 4 60 37.4 53.5 97 18 1.2 1.65 8.9 65 3.817 1 (+0.003 / 0) 4.375 7 57.3 24
450 L 6 60 37.4 53.5 103 18 1.2 1.65 8.9 65 3.817 1 (+0.003 / 0) 4.375 7 57.3 24
500 M 4 60 41.5 53.5 97.75 20 1.2 1.65 8.9 68.8 4.295 1.25 (+0.003 / 0) 5 8 61.1 26
500 M
500 L
500 L
6
2
4
60
60
60
41.5
41.5
41.5
53.5
63.25
63.25
102.5
104.5
108.25
20
20
20
1.2
1.2
1.2
1.65
1.65
1.65
8.9
8.9
8.9
68.8
68.8
68.8
4.295
3.007
4.295
1.25 (+0.003 / 0)
0.875 (+0.003 / 0)
1.25 (+0.003 / 0)
5
3.5
5
8
8
8
61.1
61.1
61.1
26
26
26
6
500 L 6 60 41.5 63.25 113 20 1.2 1.65 8.9 68.8 4.295 1.25 (+0.003 / 0) 5 8 61.1 26

AMD Poles Frequency Z5 2E 2F AF BA BS DJ FDS FDS1 N-W D-end bearing N-end bearing
Hz

450 M 4 60 2.75 32 36 18.5 21 0.5 39.3 35.75 5.3 8.25 EFNLB 11-125 EFNLQ 9-100
450 M 6 60 2.75 32 36 18.5 21 0.5 39.3 35.75 5.3 8.25 EFNLB 11-125 EFNLQ 9-100
450 L 2 60 2.4 32 45 18.5 18 1.5 39.3 42 5.3 6.5 EFNLB 9-80 EFNLQ 9-80
450 L 4 60 2.75 32 45 18.5 20 1.5 39.3 42 5.3 8.25 EFNLB 11-125 EFNLQ 9-100
450 L 6 60 2.75 32 45 18.5 20 1.5 39.3 42 5.3 8.25 EFNLB 11-125 EFNLQ 9-100
500 M 4 60 3.35 35 45 18.5 20 1.5 43 42 5.3 8.25 EFNLB 14-125 EFNLQ 9-100
500 M 6 60 3.35 35 45 18.5 20 1.5 43 42 5.3 8.25 EFNLB 14-125 EFNLQ 9-100
500 L 2 60 2.4 35 50 18.5 20 -0.5 43 52 5.3 6.5 EFNLB 9-90 EFNLQ 9-90
500 L 4 60 2.4 35 50 18.5 22.5 -0.5 43 52 5.3 8.25 EFNLB 14-125 EFNLQ 9-100
500 L 6 60 2.4 35 50 18.5 22.5 -0.5 43 52 5.3 8.25 EFNLB 14-125 EFNLQ 9-100

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 263


HV Flameproof motors, Ex d IIB T4, AMD R (IEC)
Dimension drawings
Antifriction bearings, UN 11 kV, IM 4011 (IM V1), IC01 / IC411, steel welded frame

AMD Poles Frequency D E F G L M N P S T U V V1 Y


Hz

450 M 4 50 - 60 110 210 28 100 2055 1080 1000 1150 28 6 470 325 875 300
450 M 6 - 10 50 - 60 110 210 28 100 2055 1080 1000 1150 28 6 470 325 875 300
450 L 2 50 70 140 20 62.5 2055 1080 1000 1150 28 6 470 355 1035 420
450 L 4 50 - 60 110 210 28 100 2245 1080 1000 1150 28 6 470 355 1035 300
450 L 6 - 10 50 - 60 110 210 28 100 2245 1080 1000 1150 28 6 470 355 1035 300
500 M 4 50 - 60 120 210 32 109 2310 1180 1120 1250 28 7 470 355 1035 255

6 500 M
500 L
500 L
6 - 12
4
6 - 12
50 - 60
50 - 60
50 - 60
120
120
120
210
210
210
32
32
32
109
109
109
2310
2575
2575
1180
1180
1180
1120
1120
1120
1250
1250
1250
28
28
28
7
7
7
470
470
470
355
360
360
1035
1295
1295
255
255
255

AMD Poles Frequency Z Z2 AB AC AC1 AD GD LA N holes a D-end N-end


Hz equid. bearing bearing

450 M 4 50 - 60 999 540 1160 939 1455 1195 16 30 8 22.5 6324 7321
450 M 6 - 10 50 - 60 999 540 1160 939 1455 1195 16 30 8 22.5 6324 7321
450 L 2 50 999 540 1160 939 1455 1195 12 30 8 22.5 NU215 6317
450 L 4 50 - 60 999 540 1160 939 1455 1195 16 30 8 22.5 6324 7321
450 L 6 - 10 50 - 60 999 540 1160 939 1455 1195 16 30 8 22.5 6324 7321
500 M 4 50 - 60 1044 585 1250 1043 1610 1240 18 30 8 22.5 6326 7321
500 M 6 - 12 50 - 60 1044 585 1250 1043 1610 1240 18 30 8 22.5 6326 7321
500 L 4 50 - 60 1044 585 1250 1043 1610 1240 18 30 8 22.5 6326 7321
500 L 6 - 12 50 - 60 1044 585 1250 1043 1610 1240 18 30 8 22.5 6326 7321

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

264 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d IIB T4, AMD R (NEMA)
Dimension drawings
Antifriction bearings, 1 < UN 7.2 kV, vertical, TEFC, steel welded frame

AMD Poles Frequency H P R S T U Y AB AC AC1 AF AG AH AK


Hz

450 M 4 60 1.1 37 3.817 1 (+0.003 / 0) 45.75 4.375 16.5 47 39.3 57.25 18.5 76.5 8.25 39
450 M 6 60 1.1 37 3.817 1 (+0.003 / 0) 45.75 4.375 12 47 39.3 57.25 18.5 81 8.25 39
450 L 4 60 1.1 37 3.817 1 (+0.003 / 0) 45.75 4.375 16.5 47 39.3 57.25 18.5 84 8.25 39
450 L 6 60 1.1 37 3.817 1 (+0.003 / 0) 45.75 4.375 12 47 39.3 57.25 18.5 88.5 8.25 39
500 M 4 60 1.1 41 4.041 1.25 (+0.003 / 0) 49.25 4.75 16 48.8 41.1 63.5 18.5 85.5 8.25 44
500 M 6 60 1.1 41 4.041 1.25 (+0.003 / 0) 49.25 4.75 10 48.8 41.1 63.5 18.5 91 8.25 44
500 L
500 L
4
6
60
60
1.1
1.1
41
41
4.041
4.041
1.25 (+0.003 / 0)
1.25 (+0.003 / 0)
49.25
49.25
4.75
4.75
16
10
48.8
48.8
41.1
41.1
63.5
63.5
18.5
18.5
96
101.5
8.25
8.25
44
44 6
AMD Poles Frequency AJ BB BD BV DJ LA FDS FDS1 N holes a D-end N-end
Hz equid. bearing bearing
450 M 4 60 42.5 0.25 46 13 21.3 1.25 35.7 5.3 8 22.5 6324 7321
450 M 6 60 42.5 0.25 46 13 21.3 1.25 35.7 5.3 8 22.5 6324 7321
450 L 4 60 42.5 0.25 46 14 21.3 1.25 42 5.3 8 22.5 6324 7321
450 L 6 60 42.5 0.25 46 14 21.3 1.25 42 5.3 8 22.5 6324 7321
500 M 4 60 46.5 0.25 50 14 23 1.25 42 5.3 8 22.5 6326 7321
500 M 6 60 46.5 0.25 50 14 23 1.25 42 5.3 8 22.5 6326 7321
500 L 4 60 46.5 0.25 50 14 23 1.25 52 5.3 8 22.5 6326 7321
500 L 6 60 46.5 0.25 50 14 23 1.25 52 5.3 8 22.5 6326 7321

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 265


HV Flameproof motors, Ex d IIC T4, AMD R (IEC)
Dimension drawings
Antifriction bearings, UN = 6.6 kV, IM 4011 (IM V1), IC01 / IC411, steel welded frame

AMD Poles Frequency D E F G L M N P S T U V V1 Y


Hz

450 M 4 50 110 210 28 100 2055 1080 1000 1150 28 6 360 335 865 300
450 M 6 - 10 50 110 210 28 100 2055 1080 1000 1150 28 6 360 335 865 300
450 L 2 50 70 140 20 62.5 2055 1080 1000 1150 28 6 360 365 1025 420
450 L 4 50 110 210 28 100 2245 1080 1000 1150 28 6 360 365 1025 300
450 L 6 - 10 50 110 210 28 100 2245 1080 1000 1150 28 6 360 365 1025 300

6 500 M
500 M
500 L
4
6 - 12
4
50
50
50
120
120
120
210
210
210
32
32
32
109
109
109
2310
2310
2575
1180
1180
1180
1120
1120
1120
1250
1250
1250
28
28
28
7
7
7
360
360
360
365
365
370
1025
1025
1285
255
255
255
500 L 6 - 12 50 120 210 32 109 2575 1180 1120 1250 28 7 360 370 1285 255

AMD Poles Frequency Z Z2 AB AC AC1 AD GD LA N holes a D-end N-end


Hz equid. bearing bearing

450 M 4 50 981 543 1160 939 1455 1159 16 30 8 22.5 6324 7321
450 M 6 - 10 50 981 543 1160 939 1455 1159 16 30 8 22.5 6324 7321
450 L 2 50 981 543 1160 939 1455 1159 12 30 8 22.5 NU215 6317
450 L 4 50 981 543 1160 939 1455 1159 16 30 8 22.5 6324 7321
450 L 6 - 10 50 981 543 1160 939 1455 1159 16 30 8 22.5 6324 7321
500 M 4 50 1024 588 1250 1043 1610 1202 18 30 8 22.5 6326 7321
500 M 6 - 12 50 1024 588 1250 1043 1610 1202 18 30 8 22.5 6326 7321
500 L 4 50 1024 588 1250 1043 1610 1202 18 30 8 22.5 6326 7321
500 L 6 - 12 50 1024 588 1250 1043 1610 1202 18 30 8 22.5 6326 7321

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

266 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d IIC T4, AMD R (IEC)
Dimension drawings
Antifriction bearings, UN = 11 kV, IM 4011 (IM V1), IC01 / IC411, steel welded frame

AMD Poles Frequency D E F G L M N P S T U V V1 Y


Hz

450 M 4 50 110 210 28 100 2055 1080 1000 1150 28 6 525 335 865 300
450 M 6 - 10 50 110 210 28 100 2055 1080 1000 1150 28 6 525 335 865 300
450 L 2 50 70 140 20 62.5 2055 1080 1000 1150 28 6 525 365 1025 420
450 L 4 50 110 210 28 100 2245 1080 1000 1150 28 6 525 365 1025 300
450 L 6 - 10 50 110 210 28 100 2245 1080 1000 1150 28 6 525 365 1025 300
500 M 4 50 120 210 32 109 2310 1180 1120 1250 28 7 525 365 1025 255
500 M
500 L
500 L
6 - 12
4
6 - 12
50
50
50
120
120
120
210
210
210
32
32
32
109
109
109
2310
2575
2575
1180
1180
1180
1120
1120
1120
1250
1250
1250
28
28
28
7
7
7
525
525
525
365
370
370
1025
1285
1285
255
255
255
6
AMD Poles Frequency. Z Z2 AB AC AC1 AD GD LA N holes a D-end N-end
Hz equid. bearing bearing

450 M 4 50 1038 543 1160 939 1455 1263 16 30 8 22.5 6324 7321
450 M 6 - 10 50 1038 543 1160 939 1455 1263 16 30 8 22.5 6324 7321
450 L 2 50 1038 543 1160 939 1455 1263 12 30 8 22.5 NU215 6317
450 L 4 50 1038 543 1160 939 1455 1263 16 30 8 22.5 6324 7321
450 L 6 - 10 50 1038 543 1160 939 1455 1263 16 30 8 22.5 6324 7321
500 M 4 50 1081 588 1250 1043 1610 1306 18 30 8 22.5 6326 7321
500 M 6 - 12 50 1081 588 1250 1043 1610 1306 18 30 8 22.5 6326 7321
500 L 4 50 1081 588 1250 1043 1610 1306 18 30 8 22.5 6326 7321
500 L 6 - 12 50 1081 588 1250 1043 1610 1306 18 30 8 22.5 6326 7321

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 267


HV Flameproof motors, Ex d/(e) IIB T4, AMD T (IEC)
Dimension drawings
Antifriction bearings, UN 11 kV, IM 1001 (IM B3), IC511

AMD Poles Frequency A B C D E F G H K L V V1 V2 X Z1 Z2 Z3 Z4


Hz

500 L 2 50 900 1320 224 80 170 22 71 500 42 2535 1370 350 725 200 589 550 1054 68
500 L 4 50-60 900 1320 224 110 210 32 99 500 42 2280 1370 350 725 200 624 584 1059 68
560 L 2 50 1000 1400 224 90 170 25 81 560 42 2675 1455 345 720 250 652 610 1134 60
560 L 4 50-60 1000 1400 250 120 210 32 109 560 42 2380 1480 370 745 250 652 610 1134 35
630 M 2 50 1120 1400 250 90 170 25 81 630 42 2800 1480 370 745 300 741 704 1199 74
630 M 10 - 14 50-60 1120 1500 250 140 250 36 128 630 42 2615 1580 370 745 300 719 679 1199 56
630 L 4 - 8 50-60 1120 1600 250 140 250 36 128 630 42 2715 1680 370 745 300 744 704 1232 56

6 710 M
710 L
710 X
4 - 12
4 - 12
4
50-60
50-60
50-60
1250
1250
1320
1750
2000
2100
280
280
280
160
160
160
300
300
300
40
40
40
147
147
147
710
710
710
42
42
42
2945
3195
3300
1835
2085
2185
425
425
425
800
800
800
350
350
350
744
744
851
704
704
811
1284
1284
1314
10
10
10
710 X 6 - 12 50-60 1320 2000 280 160 300 40 147 710 42 3200 2085 425 800 350 851 811 1314 10

AMD Poles Frequency Z5 Z6 AA AB AC AD1 AE1 BA BB GD HA D-end N-end


Hz bearing bearing

500 L 2 50 630 100 160 1030 1005 1247 470 350 1600 14 45 6317-C3 6317-C3
500 L 4 50-60 630 100 185 1080 1040 1252 470 350 1600 18 45 6324-C3 6319-C3
560 L 2 50 710 100 160 1150 1125 1327 470 350 1690 14 45 6319-C3 6319-C3
560 L 4 50-60 710 100 160 1150 1125 1327 470 350 1690 18 45 6326-C3 6322-C3
630 M 2 50 800 100 180 1280 1265 1392 470 350 1690 14 45 6319-C3 6319-C3
630 M 10 - 14 50-60 800 100 180 1280 1265 1392 470 350 1790 20 45 6330-C3 6324-C3
630 L 4 - 8 50-60 800 100 200 1320 1290 1425 470 350 1890 20 45 6330-C3 6324-C3
710 M 4 - 12 50-60 900 100 240 1490 1455 1477 470 350 1990 22 45 6034-C3 / NU1034 EC NU322 EC3
710 L 4 - 12 50-60 900 100 240 1490 1455 1477 470 350 2240 22 45 6034-C3 / NU1034 EC NU322 EC3
710 X 4 50-60 900 100 260 1560 1490 1507 470 350 2340 22 45 6034-C3 / NU1034 EC NU322 EC3
710 X 6 - 12 50-60 900 100 260 1560 1490 1507 470 350 2240 22 45 6034-C3 / NU1034 EC NU322 EC3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

268 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d/(e) IIB T4, AMD T (IEC)
Dimension drawings
Sleeve bearings, UN 11 kV, IM 1001 (IM B3), IC511

AMD Poles Frequency A B C D E F G H K L V V1 V2 X Z1 Z2 Z3 Z4


Hz

500 L 2 50-60 900 1320 375 80 170 22 71 500 42 2830 1520 500 875 200 589 550 1054 655
500 L 4 50-60 900 1320 400 110 210 32 99 500 42 2830 1545 525 900 200 624 584 1059 655
560 M 2 50-60 1000 1250 375 90 170 25 81 560 42 2800 1454 496 871 250 646 606 1134 715
560 L 2 50-60 1000 1400 375 90 170 25 81 560 42 3040 1565 460 830 250 646 606 1134 715
560 L 4 50-60 1000 1400 400 120 210 32 109 560 42 2670 1630 520 895 250 646 606 1134 715
630 M 2 50-60 1120 1400 375 90 170 25 81 630 42 2800 1604 496 871 300 744 704 1232 780
630 M 10 - 12 50-60 1120 1500 450 140 250 36 128 630 42 2975 1780 570 945 300 719 679 1199 780
630 L
630 L
2
4-8
50-60
50-60
1120
1120
1700
1600
375
450
100
140
210
250
28
36
90
128
630
630
42
42
3300
3020
1905
1880
495
570
870
945
300
300
744
744
704
704
1232
1232
780
780 6
AMD Poles Frequency Z5 Z6 Z7 AA AB AC AD1 AE1 BA BB GD HA D-end bearing N-end bearing
Hz

500 L 2 50-60 60 60 100 160 1030 1005 1247 470 350 1600 14 45 EFNLB 9-80 EFNLQ 9-80
500 L 4 50-60 70 60 100 185 1080 1040 1252 470 350 1600 18 45 EFNLB 11-125 EFNLQ 9-100
560 M 2 50-60 60 60 100 160 1150 1125 1327 470 350 1540 14 45 EFNLB 9-90 EFNLQ 9-90
560 L 2 50-60 60 60 100 160 1150 1125 1327 470 350 1690 14 45 EFNLB 9-90 EFNLQ 9-90
560 L 4 50-60 70 60 100 160 1150 1125 1327 470 350 1690 18 45 EFNLB 11-125 EFNLQ 9-100
630 M 2 50-60 60 60 100 180 1280 1265 1425 470 350 1690 14 45 EFNLB 9-90 EFNLQ 9-90
630 M 10 - 12 50-60 85 70 100 180 1280 1265 1392 470 350 1790 20 45 EFNLB 14-140 EFNLQ 11-125
630 L 2 50-60 60 60 100 200 1320 1290 1425 470 350 1990 16 45 EFZLB 9-100 EFZLQ 9-100
630 L 4-8 50-60 85 70 100 200 1320 1290 1425 470 350 1890 20 45 EFNLB 14-140 EFNLQ 11-125

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 269


HV Flameproof motors, Ex d/(e) IIB T4, AMD T (IEC)
Dimension drawings
Sleeve bearings, UN 11 kV, IM 1001 (IM B3), IC511

AMD Poles Frequency A B C D E F G H K L V V1 V2 X Z1 Z2 Z3 Z4


Hz

710 S 2 50-60 1250 1500 375 120 210 32 109 710 42 3310 1590 520 895 350 823 784 1283 885
710 M 2 50-60 1250 1600 400 120 210 32 109 710 42 3320 1805 545 920 350 800 760 1284 865
710 M 4-6 50-60 1250 1750 450 160 300 40 147 710 42 3315 2005 595 970 350 744 704 1284 865
710 M 8 - 12 50-60 1250 1750 450 160 300 40 147 710 42 3315 2005 595 970 350 744 704 1284 865
710 L 4-6 50-60 1250 2000 450 160 300 40 147 710 42 3565 2255 595 970 350 744 704 1284 865
710 L 8 - 12 50-60 1250 2000 450 160 300 40 147 710 42 3565 2255 595 970 350 744 704 1284 865

6 710 X
710 X
710 X
2
4
6 - 12
50-60
50-60
50-60
1250
1320
1320
1800
2100
2000
375
450
450
120
175
175
210
300
300
32
45
45
109
160
160
710
710
710
42
42
42
3600
3900
3800
1980
2355
2255
520
595
595
895
970
970
350
350
350
821 781 1284 885
851 811 1314 910
851 811 1314 910

AMD Poles Frequency Z5 Z6 Z7 AA AB AC AD1 AE1 BA BB GD HA D-end bearing N-end bearing


Hz

710 S 2 50-60 70 70 100 240 1490 1448 1476 470 350 1740 18 45 EFZLB 11-125 EFZLQ 11-125
710 M 2 50-60 70 70 100 220 1450 1425 1477 470 350 1840 18 45 EFZLB 11-125 EFZLQ 11-125
710 M 4-6 50-60 85 85 100 240 1490 1455 1477 470 350 1990 22 45 EFZLB 14-160 EFZLQ 14-160
710 M 8 - 12 50-60 85 85 100 240 1490 1455 1477 470 350 1990 22 45 EFNLB 14-160 EFNLQ 14-160
710 L 4-6 50-60 85 85 100 240 1490 1455 1477 470 350 2240 22 45 EFZLB 14-160 EFZLQ 14-160
710 L 8 - 12 50-60 85 85 100 240 1490 1455 1477 470 350 2240 22 45 EFNLB 14-160 EFNLQ 14-160
710 X 2 50-60 70 70 100 240 1490 1510 1477 470 350 2040 18 45 EFZLB 11-125 EFZLQ 11-125
710 X 4 50-60 85 85 100 260 1560 1490 1507 470 350 2340 25 45 EFZLB 14-180 EFZLQ 14-180
710 X 6 - 12 50-60 85 85 100 260 1560 1490 1507 470 350 2240 25 45 EFZLB 14-180 EFZLQ 14-180

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

270 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


HV Flameproof motors, Ex d/(e) IIB T4, AMD T (IEC)
Dimension drawings
Antifriction bearings, UN 11 kV, IM 4011 (IM V1), IC511

AMD Poles Frequency D E F G L M N P S T V V1 V2 Y Z1


Hz

500 L 4 50-60 110 210 32 99 2300 1180 1120 1250 28 7 1390 370 745 340 589
560 L 4 50-60 120 210 32 109 2380 1320 1250 1400 28 8 1484 350 725 340 589
630 M 10 - 14 50-60 140 250 36 128 2565 1500 1400 1600 26 10 1581 373 748 340 719
630 L 4 - 12 50-60 140 250 36 128 2665 1500 1400 1600 26 10 1681 373 748 340 719
710 M 4 - 12 50 160 300 40 147 2950 1700 1600 1800 26 10 1841 433 808 400 800
710 L 4 - 12 50 160 300 40 147 3194 1700 1600 1800 26 10 2091 433 808 400 800

AMD Poles Frequency


Hz
Z2 Z3 AC AC1 AD1 AE1 GD LA N holes
equid.
a b D-end
bearing
N-end
bearing
6
500 L 4 50-60 549 1059 1010 1250 1252 470 18 30 8 45 22.5 6024-C3 7319
560 L 4 50-60 550 1134 1090 1360 1327 470 18 40 8 45 22.5 6026-C3 7322
630 M 10 - 14 50-60 679 1199 1230 1500 1392 470 20 37 12 30 5 6030-C3 7324
630 L 4 - 12 50-60 679 1199 1230 1500 1392 470 20 37 12 30 5 6030-C3 7324
710 M 4 - 12 50 760 1284 1380 1660 1477 470 22 47 12 30 5 6034-C3 7330
710 L 4 - 12 50 760 1284 1380 1660 1477 470 22 47 12 30 5 6034-C3 7330

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
The motor's rotational direction will be as specied in the order.

ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008 271


6

272 ABB/ BU Machines / Motors for COG / Flameproof EN 02-2008


Class I Standard NEMA motors
Totally enclosed squirrel cage three phase high
voltage motors,
Sizes 506AT - 728, 150 to 950 HP

www.abb.com/motors&generators
> Motors
>> Motors and Generators for Hazardous Areas

Mechanical design........................... 274


Ordering information ....................... 284
Rating plates .................................... 285
7
Technical data .................................. 286
Variant codes ................................... 288
Dimension drawings ....................... 290
Accessories ..................................... 293
Construction .................................... 294
Motor in brief.................................... 295
ABB reserves the right to change the design,
technical specication and dimensions
without prior notice.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 273


Mechanical design
This is a standard NEMA motor catalogue with limited engineered cast iron NEMA motor, please contact your
optional features and accessories. In case you need an local ABB Sales ofce for further information.

Stator frame
The motor frames feature integrally cast feet to provide Motors can be supplied for foot mounting (F1 & F2) or
a very rigid mounting and minimal vibration; the feet and foot and ange mounting. The terminal box is made of
bearing housing are made of cast iron. structural steel.

Drain holes
All the high voltage motors are tted with drain holes In very dusty environments, both plugs should be
and closable plugs. The drain hole plugs are open on hammered home.
delivery and users must ensure that the drain holes face
downward when mounting the motors.

Motor sizes 506AT-728


As standard with drain holes and closable plugs.

274 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Terminal boxes
NEMA terminal boxes for M3GM motors.

Type I
Technical data: Materials:

Voltage (max.) 4.8 kV Box welded sheet steel


Current (max.) 700 A (thickness min. 3 mm (0.12"))
No of cables (max.) 2 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable (0.465 in2) Grounding pad stainless steel
Cable gland blind gland (1 pce)
Gross volume 98.3 dm3 (6000 in3) Other features:
Ground connections M12 (inside) - rigid welded construction
Weight 42 kg (92 lbs) - box turnable to allow cable entry from left or right side
Protection IP 66 - box turnable in steps of 90.
Standard NEMA MG 1, Part 20

Type I terminal box.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 275


Type II

Technical data: Materials:


Voltage (max.) 6.9 kV Box welded sheet steel
Current (max.) 600 A (thickness min. 3 mm (0.12"))
No of cables (max.) 2 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable (0.465 in2) Connection hooks Copper Cu
Cable gland blind gland (1 pce) Isolators epoxy casting resin
Connection hooks 0.3" x 2.36" (3 pcs) Grounding pad stainless steel
Clearance (min.) 149.8 mm (5.9 in)
Creepage (min.) 249 mm (10 in) Other features:
Usable volume 0.295 m3 (18 000 in3) - rigid welded construction
Ground connections M16 (both in- and - ample size for making connections of supply cables
outside) - box turnable to allow cable entry from left or right side
Weight 105 kg (230 lbs) - box turnable in steps of 90.
Protection IP 66
Standard NEMA MG 1, Part 20

Type II terminal box.

276 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Dimensions for terminal box inlet, blind ange

Type I

Type II

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 277


Auxiliary boxes
Auxiliary box is used for control equipment and heating
elements.

- one box as default Other features:


- stator Pt-100 - equipped with assembly rail ARH 22
- bearing Pt-100 (optional, variant code 107) (DIN-35, 35 x 203 mm (1.38" x 7.99"))
- heating element (optional, variant code 450/451) - main dimensions 125 mm x 222 mm x 81 mm
- separate auxiliary box for heating element (optional, (4.92" x 8.74" x 3.19")
variant code 447) - cable gland M20
- degree of protection IP 66 (IEC 529)
Specication: - gasket material polyurethane
- temperature resistance -55 - +80 C
7 Material designation
Material standard
Surface treatment
Al-Si10Mg (pressure die cast)
EN 573-3
RAL 7001 (grey)
- max. terminal blocks:
34 pcs 0.004 in2 (2.5 mm2) AWG = 14
- weight 1.6 kg (3.53 lbs)

278 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Bigger auxiliary box

- one box as default Other features:


- stator Pt-100 (6 pcs) - equipped with assembly rail ARH 22 (DIN-35)
- bearing Pt-100 (optional, variant code 107) - main dimensions 230 mm x 330 mm x 180 mm
- separate box for heating element (variant code (9.1x12.99x7.09)
450/451) - degree of protection IP 66 (IEC 529)
- Provision for vibration sensors (optional, variant - gasket material silicone
code 654*) - temperature resistance -55 - +100 C
* The bigger auxiliary box is needed if the variant code 654 is - max. terminal blocks:
selected. 36 pcs 0.004 in2 (2.5 mm2) AWG = 14
Specication: - weight 5.6 kg (12.3 lbs) 7
Material designation Al-Si10Mg (pressure die cast)
Material standard EN 573-3
Surface treatment RAL 7001 (grey)

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 279


Bearings
The motors are normally tted with single-row deep If the bearing at the D-end is replaced with a roller
groove ball bearings as listed in the table below. bearing (NU-), higher radial forces can be handled.
Roller bearings are suitable for belt drive applications.

Basic version with deep groove ball bearings Version with roller bearings, variant code 037
Motor Number Deep groove ball bearings Motor Number Roller bearings, variant code 037
size of poles D-end N-end size of poles D-end
506AT 2 6316M/C3 6316M/C3 506AT 4-6 NU 319M/C3
4-6 6319/C3 6316/C3 587 4-6 NU 322M/C3
587 2 6316M/C3 6316M/C3 68_ 4-8 NU 324M/C3
4-6 6322/C3 6316/C3 728 4-8 NU 326M/C3
68_ 2 6317M/C3 6317M/C3
4-8 6324/C3 6319/C3
728 2 6317M/C3 6317M/C3
4-8 6326M/C3 6322/C3

Axially-locked bearings
All motors are equipped as standard with an axially- The N-end bearing is axially free and can take the
locked bearing at the D-end. thermal expansion. Note! NU-bearing is axially locked
at N-end.
The bearing's outer ring is tightly locked between
bearing's covers and the housing t.

Transport locking
Motors with roller bearings are tted with a transport Locking may be tted in other situations where the
lock to prevent damage to the bearings during transport. transport conditions are considered as potentially
All high voltage motors are tted with a warning sign damaging.
when the transport lock is tted to prevent operational
damage and alert operators.

280 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Bearing seals
All high voltage motors are equipped with labyrinth
sealed bearings.

Axially free (N-end)

Axially locked (D-end)

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 281


Lubrication
On delivery, the motors are pre-lubricated with high Motors with relubrication nipples
quality grease. The grease grade is stamped on the Motors are lubricated while running and the bearing
lubrication plate fastened to the motor frame. See page system on all high voltage motors has been built so that
285 for an example of a lubrication plate. a valve disc can be used for lubrication.
More information about lubrication and greases can The grease outlet opening has closing valves at both
be found in ABB's High Voltage Process Performance ends that should be opened before greasing and closed
Manual delivered with the motor. 1-2 hours after regreasing. Closing the valves ensures
that the construction is tight and prevents dust or dirt
getting inside the bearing.

Lubrication intervals
The lubrication interval is dened by following the The table below gives lubrication intervals for different
L1-principle. This means that 99% of ABB's motors speeds (according to the L1-principle). The values are
will achieve normal service intervals. Values for the valid for horizontal mounted motors (B3), using the
lubrication intervals can also be calculated according synthetic base oil mentioned in ABB's High Voltage
to the L10-principle, which are normally doubled Process Performance Motors Manual.
compared to L1-values. Values are available from ABB
For more information, see ABB's High Voltage Process
on request.
Performance Motors Manual.

Frame 3600 1800 <1200 Frame 3600 1800 <1200


size Ambient C r/min r/min r/min size Ambient C r/min r/min r/min

Ball bearings, horizontal motor: lubrication intervals in duty hours Roller bearings: lubrication intervals in duty hours
506AT 25 3000 8800 8800 506AT 25 - 4400 5900
506AT 40 1500 5100 8800 506AT 40 - 2200 3000
587 25 3000 7300 8800 587 25 - 3000 4400
587 40 1500 3600 8000 587 40 - 1500 2200
68_ 25 2200 5900 8800 68_ 25 - 2200 4400
68_ 40 1100 3000 6600 68_ 40 - 1100 2200
728 25 2200 5900 8800 728 25 - 2200 4400
728 40 1100 3000 8800 728 40 - 1100 2200
Note! The lubrication intervals dened at SF 1.0.

Note! Special grease for roller bearings.

282 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Permissible radial forces

Length of Ball bearings Roller bearings


shaft SI units Imperial units SI units Imperial units
Motor extension 40,000 hours 40,000 hours
size Poles E (mm) FX0 (N) FXmax(N) FX0 (lbs) FXmax(lbs) FX0 (N) FXmax(N) FX0 (lbf) FXmax(lbf)

506 2 140 4600 4100 1034 922 - - - -


4 170 7550 6550 1697 1472 24600 9500 5530 2136
6 170 8450 7300 1900 1641 27600 9500 6205 2136
587 2 140 2050 1850 461 416 - - - -
4 210 9200 7950 2068 1787 33300 12000 7486 2698
6 210 10700 9250 2405 2079 37750 12000 8487 2698
68_ 2 170 300 250 67 56 - - - -
4 210 6770 5980 1522 1344 38100 15000 8565 3372
6 210 9030 7960 2030 1789 42300 15000 9509 3372
728 2 170 - - - - - - - -
4 210 7400 6570 1664 1477 50550 21000 11364 4721
6 210 9440 8390 2122 1886 56850 21000 12780 4721

Permissible axial forces


The following tables give the permissible axial forces Given axial forces FAD, assumes D-bearing locked by
in Newton, assuming zero radial force. The values are means of locking ring.
based on normal conditions at 60 Hz with standard
bearings and calculated bearing lives L10h 40,000 hours.

Mounting arrangement IM B3

FAD  FAZ

SI units 40,000 hours


2-pole 4-pole 6-pole
Motor FAD FAZ FAD FAZ FAD FAZ
size N N N N N N
506 1850 3850 3800 5800 4600 6600
587 750 4550 3800 7600 5000 8800
68_ 100 5100 2480 8480 3340 9340
728 - 4600 2640 8640 3570 9570

Imperial units 40,000 hours


2-pole 4-pole 6-pole
Motor
size
506
FAD
lbf
416
FAZ
lbf
865
FAD
lbf
854
FAZ
lbf
1303
FAD
lbf
1034
FAZ
lbf
1483
7
587 169 1022 854 1708 1124 1978
68_ 22 1146 557 1906 751 2099
728 - 1034 593 1942 802 2151

Vibration limits
The following table lists the vibration values that the Poles Speed Design Bearing housing
motors full in compliance with IEC 60034-14. rpm vibration
2 1800 < n 3600 Standard 0.1 in./s peak (2.54 mm/s)
4 1800 Standard 0.1 in./s peak (2.54 mm/s)

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 283


Ordering information
Sample order
When placing an order, please state the following Motor type M3BM 587 LKA
minimum data in the order, as in example. Pole number 2
Mounting arrangement (IM code) IM B3 (IM 1001)
The product code of the motor is composed in Rated output 250 HP
accordance with the following example. Product code 3GBM981810-APA
Variant codes if needed

Motor size A Motor type


B Motor size
A B C D, E, F, G C Product code
D Mounting arrangement code
M3BM 587LKA 3GBM 981 810 - A P A 003 etc. E Voltage and frequency code
F Generation code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 G Variant codes

Explanation of the product code:


Positions 1 to 4 Position 11
3GBM, 3GGM = Totally enclosed fan cooled squirrel cage motor with - (dash)
cast iron frame, high voltage
Position 12
Positions 5 and 6 Mounting arrangement
NEMA-frame A = Foot mounted, terminal box on top (F0)
90 = 50_ H = Foot and ange mounting, D ange, terminal box on top (F0)
98 = 58_
99 = 68_ Position 13
02 = 72_ Voltage and frequency code
See table below
Position 7
Speed (Pole pairs) Position 14
1 = 2 poles Generation code
2 = 4 poles A, B, C...
3 = 6 poles The product code must be, if needed, followed by variant codes.
4 = 8 poles

Position 8 to 10
Serial number

Code letters for supplementing the product code - single speed motors

Code letter for voltage and frequency


W
60 Hz
4000 V

284 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Rating plate

Rating plate, HV motor

Lubrication plate

7
Lubrication plate, HV motor

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 285


NEMA Non-sparking HV cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 TEFC / IC 411 Insulation class F, temperature rise class B, ambient temperature 40 C, S.F. 1.15
Efciency Power factor Current
Full 3/4 Full 3/4 FLA at KV LRA NLC
Output Motor type Product code Speed load load load load 4 (Y) 2.3 (D)
HP r/min r/min 100% 75% 100% 75% A A % Code A

4000 V (star) or 2.3 kV (delta) 60 Hz


4)
250 3600 M3GM 587 LKA 3GGM 981811 sWA 3579 93.0 92.4 0.90 0.89 32 56 630 G 7
4)
300 3600 M3GM 587 LKB 3GGM 981821 sWA 3580 93.7 93.3 0.91 0.90 38 66 640 G 8
4)
350 3600 M3GM 587 LKC 3GGM 981831 sWA 3579 94.1 93.8 0.91 0.90 44 77 640 F 9
4)
400 3600 M3GM 688 LA 3GGM 991511 sWA 3581 94.3 93.9 0.89 0.88 51 89 640 G 12
4)
450 3600 M3GM 688 LB 3GGM 991521 sWA 3580 94.7 94.4 0.90 0.90 57 98 640 F 12
4)
480 3600 M3GM 688 LC 3GGM 991532 sWA 3580 94.7 94.5 0.91 0.90 60 105 670 G 12
4)
530 3600 M3GM 688 LD 3GGM 991542 sWA 3579 95.1 94.9 0.91 0.91 66 115 660 G 12
4)
600 3600 M3GM 728 LA 3GGM 021510 sWA 3587 95.0 94.6 0.90 0.89 76 132 650 G 18
4)
700 3600 M3GM 728 LB 3GGM 021520 sWA 3587 95.4 95.2 0.91 0.90 87 152 650 F 17
4)
800 3600 M3GM 728 LC 3GGM 021530 sWA 3586 95.7 95.5 0.91 0.91 99 173 640 F 19
4)
880 3600 M3GM 728 LD 3GGM 021541 sWA 3586 95.9 95.7 0.91 0.91 109 189 650 F 20
200 1800 M3GM 506AT LKA 3GGM 902811 sWA 1788 94.0 93.6 0.85 0.82 27 47 650 G 9
250 1800 M3GM 506AT LKB 3GGM 902821 sWA 1787 94.2 94.0 0.85 0.81 34 59 620 G 13
275 1800 M3GM 506AT LKC 3GGM 902830 sWA 1786 94.4 94.2 0.85 0.81 37 65 620 G 14
300 1800 M3GM 587 LKA 3GGM 982811 sWA 1790 94.0 93.6 0.82 0.79 42 73 600 G 16
350 1800 M3GM 587 LKB 3GGM 982821 sWA 1789 94.3 94.1 0.83 0.81 48 83 600 G 17
400 1800 M3GM 587 LKC 3GGM 982831 sWA 1790 94.7 94.5 0.83 0.80 55 95 650 G 20
450 1800 M3GM 587 LKD 3GGM 982841 sWA 1789 95.0 94.9 0.86 0.84 60 104 620 G 18
500 1800 M3GM 587 LKE 3GGM 982851 sWA 1791 95.1 94.9 0.86 0.83 66 115 630 G 22
600 1800 M3GM 688 LA 3GGM 992511 sWA 1792 95.9 95.7 0.85 0.82 79 138 640 G 27
700 1800 M3GM 689 LKA 3GGM 992810 sWA 1791 95.9 95.9 0.85 0.83 92 160 630 G 31
780 1800 M3GM 689 LKB 3GGM 992820 sWA 1792 96.1 96.0 0.85 0.83 102 178 650 G 34
880 1800 M3GM 728 LA 3GGM 022511 sWA 1793 95.9 95.6 0.86 0.84 115 199 660 G 35
175 1200 M3GM 506AT LKB 3GGM 903821 sWA 1192 93.8 93.5 0.76 0.70 26 46 640 H 13
250 1200 M3GM 587 LKA 3GGM 983811 sWA 1191 94.5 94.4 0.79 0.74 36 63 550 F 16
300 1200 M3GM 587 LKB 3GGM 983821 sWA 1192 94.8 94.7 0.79 0.75 43 75 580 G 18
350 1200 M3GM 587 LKC 3GGM 983831 sWA 1191 95.0 95.0 0.80 0.76 50 86 560 F 20
400 1200 M3GM 587 LKD 3GGM 983841 sWA 1192 95.3 95.2 0.80 0.76 57 98 610 G 23
450 1200 M3GM 587 LKE 3GGM 983850 sWA 1193 95.3 95.3 0.80 0.76 64 111 600 G 27
450 1200 M3GM 688 LA 3GGM 993511 sWA 1192 95.4 95.3 0.80 0.76 63 110 610 G 26
500 1200 M3GM 688 LB 3GGM 993521 sWA 1195 95.7 95.5 0.79 0.74 72 124 630 G 32
600 1200 M3GM 689 LKA 3GGM 993810 sWA 1195 95.9 95.7 0.79 0.74 86 149 630 G 38
670 1200 M3GM 689 LKB 3GGM 993821 sWA 1195 95.9 95.8 0.79 0.74 96 166 630 G 43
800 1200 M3GM 728 LA 3GGM 023510 sWA 1194 95.9 95.8 0.84 0.81 107 186 630 G 37
870 1200 M3GM 728 LB 3GGM 023521 sWA 1194 96.0 95.9 0.84 0.81 116 202 630 G 40
950 1200 M3GM 728 LC 3GGM 023530 sWA 1194 96.1 96.1 0.84 0.81 127 220 640 G 44
150 900 M3GM 688 LA 3GGM 994511 sWA 893 93.6 93.2 0.76 0.70 23 40 540 G 11
200 900 M3GM 688 LB 3GGM 994521 sWA 892 93.9 93.6 0.76 0.70 30 53 550 G 15
250 900 M3GM 688 LC 3GGM 994531 sWA 892 94.0 93.7 0.75 0.69 38 66 560 G 19
300 900 M3GM 688 LD 3GGM 994541 sWA 891 94.3 94.2 0.77 0.72 45 78 530 F 20
350 900 M3GM 688 LE 3GGM 994551 sWA 891 94.7 94.5 0.77 0.72 52 90 560 G 24
400 900 M3GM 689 LKA 3GGM 994810 sWA 895 94.9 94.8 0.77 0.72 59 103 550 G 28

7 450
490
540
900
900
900
M3GM
M3GM
M3GM
689 LKB
689 LKC
689 LKD
3GGM
3GGM
3GGM
994820 sWA
994831 sWA
994841 sWA
895
895
895
95.1
95.1
95.3
94.9
94.9
95.0
0.76
0.76
0.75
0.71
0.70
0.69
67
73
81
116
127
141
580
600
620
G
G
H
33
36
42
600 900 M3GM 728 LA 3GGM 024510 sWA 895 95.4 95.3 0.80 0.77 84 147 550 F 34
700 900 M3GM 728 LB 3GGM 024520 sWA 895 95.6 95.4 0.79 0.75 99 173 590 G 42
750 900 M3GM 728 LC 3GGM 024530 sWA 896 95.7 95.5 0.80 0.75 106 184 600 G 45
1)
3600 r/min: quadratic load torque with 90% of the rated torque at the rated speed and at
587LK, 688L: The given values of load inertia assume two starts from cold and 80% of the rated voltage.
one start from warm conditions in succession against quadratic load torque with Motors full the starting requirements in NEMA MG 1, Part 20.
90% of the rated torque at the rated speed and at 80% of the rated voltage.
2)
689LK, 728L: The given values of load inertia assume two starts from cold and Starting time with given values of the load inertia from cold condition in
one start from warm conditions in succession against quadratic load torque with succession against quadratic load torque dened in footnote 1).
85% of the rated torque at the rated speed and at 80% of the rated voltage. 3)
The sound pressure levels are presented at no-load. The magnetic noise
1800 r/min: level of 2- and 4-pole motors is typically low compared to the fan noise,
506AT LK, 587LK, 688L, 689LK: The given values of load inertia assume three resulting no increase in the noise level on-load. Sound level values of
starts from cold and two starts from warm conditions in succession against 6...8-pole motors at on-load are typically 1...3 dB(A) higher than the
quadratic load torque with 90% of the rated torque at the rated speed and at 80% corresponding values at no-load. The variation and measuring tolerance of
of the rated voltage. the gures is +3 dB(A).
728L: The given values of load inertia assume three starts from cold and two 4)
Unidirectional fan construction as standard. Direction of rotation must be
starts from warm conditions in succession against quadratic load torque with stated when ordering, see variant codes 044 and 045.
85% of the rated torque at the rated speed and at 80% of the rated voltage.
1200 r/min and 900 r/min: The given values of load inertia assume three The bullet in the product code indicates choice of
starts from cold and two starts from warm conditions in succession against mounting arrangement (see ordering information page).

286 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


NEMA Non-sparking HV cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 TEFC / IC 411 Insulation class F, temperature rise class B, ambient temperature 40 C, S.F. 1.15
Torque Power Load Starting Maximum Sound
Rated LRT BDT factor inertia time stalling Rotor Rotor Motor pressure
Output Motor type 1) at start 1)
cold 2) time hot inertia weight weight level 3)
HP r/min lb-ft % % cos k lb-ft2
s s lb-ft 2
lbs lbs dB(A)

4000 V (star) or 2.3 kV (delta) 60 Hz


4)
250 3600 M3GM 587 LKA 367 90 270 0.13 210 10 18 68.5 610 3960 82
4)
300 3600 M3GM 587 LKB 440 100 270 0.13 246 9 16 79.7 680 4270 82
4)
350 3600 M3GM 587 LKC 514 100 270 0.13 281 9 14 83.4 700 4370 82
4)
400 3600 M3GM 688 LA 587 80 270 0.11 315 11 20 137 880 5160 83
4)
450 3600 M3GM 688 LB 660 90 270 0.12 349 10 18 158 980 5560 83
4)
480 3600 M3GM 688 LC 704 90 270 0.12 368 9 13 140 1010 5650 83
4)
530 3600 M3GM 688 LD 778 90 270 0.11 400 9 12 150 1080 5960 83
4)
600 3600 M3GM 728 LA 878 60 290 0.08 443 12 20 208 1350 7960 87
4)
700 3600 M3GM 728 LB 1025 70 280 0.08 503 11 20 262 1560 8960 87
4)
800 3600 M3GM 728 LC 1172 70 270 0.08 560 12 20 344 1640 9300 87
4)
880 3600 M3GM 728 LD 1289 70 270 0.09 604 11 15 310 1750 9810 87
200 1800 M3GM 506AT LKA 588 170 260 0.20 831 6 20 54.1 570 3140 78
250 1800 M3GM 506AT LKB 735 100 280 0.14 1016 8 17 47.4 510 2910 78
275 1800 M3GM 506AT LKC 809 100 270 0.14 1107 8 16 49.8 530 2990 78
300 1800 M3GM 587 LKA 881 110 240 0.15 1197 9 16 103 750 3940 80
350 1800 M3GM 587 LKB 1028 110 240 0.15 1373 8 16 116 820 4120 80
400 1800 M3GM 587 LKC 1174 120 250 0.15 1545 7 14 129 880 4340 80
450 1800 M3GM 587 LKD 1322 110 230 0.14 1714 8 14 154 1010 4730 80
500 1800 M3GM 587 LKE 1467 100 270 0.13 1879 9 16 180 1120 5000 80
600 1800 M3GM 688 LA 1759 100 280 0.11 1879 9 15 280 1400 6540 80
700 1800 M3GM 689 LKA 2053 100 270 0.12 2513 9 12 295 1500 6980 80
780 1800 M3GM 689 LKB 2287 100 280 0.11 2755 8 12 354 1730 7750 80
880 1800 M3GM 728 LA 2579 110 270 0.12 3050 8 22 570 2350 10290 83
175 1200 M3GM 506AT LKB 772 130 300 0.16 5125 8 15 75.1 640 2940 70
250 1200 M3GM 587 LKA 1103 130 230 0.18 2743 9 20 122 840 4140 76
300 1200 M3GM 587 LKB 1323 140 230 0.18 3238 8 20 150 980 4530 76
350 1200 M3GM 587 LKC 1544 140 220 0.17 3722 8 20 164 1050 4730 76
400 1200 M3GM 587 LKD 1764 150 240 0.17 4197 7 20 206 1270 5340 76
450 1200 M3GM 587 LKE 1982 100 250 0.13 4664 9 20 210 1270 5360 76
450 1200 M3GM 688 LA 1983 140 240 0.15 4665 8 20 280 1420 6330 80
500 1200 M3GM 688 LB 2198 120 280 0.13 5125 9 20 440 1780 6660 80
600 1200 M3GM 689 LKA 2638 130 280 0.13 6025 9 20 507 2050 7530 80
670 1200 M3GM 689 LKB 2946 130 280 0.13 6640 8 22 510 2150 7740 80
800 1200 M3GM 728 LA 3519 130 250 0.15 7755 7 20 780 2500 9510 82
870 1200 M3GM 728 LB 3827 140 250 0.15 8341 7 21 770 2640 9840 82
950 1200 M3GM 728 LC 4179 140 250 0.15 9000 7 20 883 2770 10210 82
150 900 M3GM 688 LA 883 100 260 0.14 3455 11 22 232 1200 5590 80
200 900 M3GM 688 LB 1177 110 270 0.13 4507 10 22 243 1240 5730 80
250 900 M3GM 688 LC 1472 110 270 0.14 5533 9 22 254 1290 5810 80
300 900 M3GM 688 LD 1769 100 250 0.14 6539 10 22 287 1420 6200 80
350 900 M3GM 688 LE 2063 110 260 0.13 7526 9 22 342 1630 6910 80
400 900 M3GM 689 LKA 2349 120 230 0.17 8497 10 20 427 1770 6770 80
450
490
540
900
900
900
M3GM
M3GM
M3GM
689 LKB
689 LKC
689 LKD
2641
2876
3169
130
130
140
240
250
270
0.17
0.17
0.16
9453
10209
11142
10
9
8
20
22
22
491
490
520
1980
2090
2200
7280
7500
7790
80
80
80
7
600 900 M3GM 728 LA 3522 100 220 0.13 12246 12 20 731 2380 9190 78
700 900 M3GM 728 LB 4107 110 240 0.13 14053 10 20 835 2650 9810 78
750 900 M3GM 728 LC 4400 110 250 0.13 14942 10 20 938 2920 10470 78
1)
When ordering, the following variant codes have to be added to the product code acc. to needs.
for non-sparking motors:
807 CSA Design, Class I Div 2 Group A,B,C,D T3
809 CSA Design, Class I Zone 2 Ex nA IIC T3

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 287


NEMA Non-sparking HV Cast iron motors - Variant codes
Code Variant Motor size
1)
506AT 587 68_ 728
Balancing
423 Balanced without key P P P P
424 Full key balancing. P P P P
Bearings and lubrication
036 Transport lock for bearings. P P P P
037 Roller bearing at D-end. P P P P
107 PT100 2-wire in bearings. P P P P
654 Provision for vibration sensors (M8x1) P P P P
Branch standard designs
178 Stainless steel/acid proof bolts. P P P P
398 Motor designed for ambient temperature -20C to -40C P P P P
Cooling system
044 Unidirectional fan, clockwise seen from D-end. NA P P P
045 Unidirectional fan, counter clockwise seen from D-end. NA P P P
068 Metal fan. P P P P
Coupling
035 Assembly of customer supplied coupling-half. P P P P
Drain holes
065 Plugged existing drain holes. P P P P
448 Draining holes with metal plugs. P P P P
Hazardous environments
Motor type M3GM.
807 CSA design, Class I, Div 2 Group A, B, C, D T3 P P P P
809 CSA design, Class I, Zone 2 AEx nA IIC T3 and Ex nA II T3 P P P P
Heating elements
450 Heating element, 100-120 V. P P P P
451 Heating element, 200-240 V. P P P P
Painting
114 Special paint colour, standard grade. P P P P
754 Painting system C5M - Coastal and offshore areas with high salinity P P P P
Protection
158 Degree of protection IP 65. P P P P
403 Degree of protection IP 56. P P P P
Rating & instruction plates
002 Restamping voltage, frequency and output, continuous duty. P P P P

7 010
Standards and regulations
Fullling CSA Safety Certicate. S S S S

1)
Certain variant codes cannot be used simultaneously. P = New manufacture only. NA = Not applicable.
R = On request. S = Included as standard.

288 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Code Variant Motor size
1)
506AT 587 68_ 728
Terminal box
019 Larger than standard terminal box. P P P P
021 Terminal box LHS (seen from D-end). P P P P
447 Top mounted separate terminal box for monitoring equipment. P P P P
656 No terminal box, six (6) leads out 1.5 m (5 ft) P P P P
750 Star point terminal box. P P P P
Testing
146 Type test with report for motor from specic delivery patch. P P P P
147 Type test with report for motor from specic delivery patch, customer witnessed. P P P P
762 Noise level test. P P P P
Variable speed drives
701 Insulated bearing at N-end P P P P
Foundation and installation
Foundation studs P P P P
Sole plates without anchor bolts. P P P P
Sole plates with anchor bolts. P P P P
Slide rails for belt drives. P P P P

1)
Certain variant codes cannot be used simultaneously. P = New manufacture only. NA = Not applicable.
R = On request. S = Included as standard.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 289


NEMA Non-sparking HV Cast iron motors Sizes 506AT-728
Dimension drawings
Type I, Foot-mounted motors, IM B3 (IM 1001)

Motor Poles 2E 2F 2F' 2F'' BA U N-W F D FP O C A B J


size
506AT 2 20 20 22 28 8.5 2.5 5.5 0.625 12.5 47.9 38.2 58.7 23.2 33.5 3.2
506AT 4-6 20 20 22 28 8.5 3.5 6.5 0.875* 12.5 47.9 38.2 59.7 23.2 33.5 3.2
587 2 23 25 28 36 10 2.75 5.5 0.625 14.5 53.4 41.9 69.4 27.6 42.4 4.7
587 4-6 23 25 28 36 10 4 8.25 1* 14.5 53.4 41.9 72.2 27.6 42.4 4.7
688 2 27 - 32 36 11.5 3.125 6.5 0.75 17 53.4 46.1 72.7 33.1 45.5 5.9
688 4-8 27 - 32 36 11.5 4.375 8.25 1* 17 53.4 46.1 74.4 33.1 45.5 5.9
689 2 27 40 - - 11.5 3.125 6.5 0.75 17 53.4 46.1 79 33.1 51.8 5.9
689 4-8 27 40 - - 11.5 4.375 8.25 1* 17 53.4 46.1 80.7 33.1 51.8 5.9
728 2 32 36 - - 16 3.125 6.5 0.75 18 56.9 51.7 84.3 37.4 55.9 6.3
728 4-8 32 36 - - 16 4.375 8.25 1* 18 56.9 51.7 86.1 37.4 55.9 6.3

Motor Poles G P K H R AB OE BSX FDX CX

7 size
506AT 2 1.7 25.7 13.2 1.26 2.148 32.7 14.4 14 41.5 4.5
506AT 4-6 1.7 25.7 13.2 1.26 3.007 32.7 14.4 15 42.5 4.5
587 2 2.3 29.4 17.6 1.38 2.402 35.5 18.1 15.7 51.5 9.8
587 4-6 2.3 29.4 17.6 1.38 3.436 35.5 18.1 18.4 54.3 5.1
688 2 3 32.8 16.2 1.38 2.704 35.5 22.2 17.8 53.3 11.8
688 4-8 3 32.8 16.2 1.38 3.817 35.5 22.2 19.6 55 7.9
689 2 1 32.8 16.2 1.38 2.704 35.5 22.2 18.6 59.6 11.8
689 4-8 3 32.8 16.2 1.38 3.817 35.5 22.2 20.4 61.3 7.9
728 2 1.2 37 17.7 1.65 2.704 37 27.8 18.9 63.1 11.8
728 4-8 3.5 37 17.7 1.65 3.817 37 27.8 20.7 64.9 7.9

Tolerances: Above table gives the main dimensions in inches.


U +0 -0.001 F* +0 -0.003
For detailed drawings please see our web-pages
F +0 - 0.0025 D +0 -0.06 'www.abb.com/motors&generators' or contact us.

290 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


NEMA Non-sparking HV Cast iron motors Sizes 506AT-728
Dimension drawings
Type II, Foot-mounted motors, IM B3 (IM 1001)

Motor Poles 2E 2F 2F' 2F'' BA U N-W F D FP O C A B J


size
506AT 2 20 20 22 28 8.5 2.5 5.5 0.625 12.5 48.8 51.3 58.7 23.2 33.5 3.2
506AT 4-6 20 20 22 28 8.5 3.5 6.5 0.875* 12.5 48.8 51.3 59.7 23.2 33.5 3.2
587 2 23 25 28 36 10 2.75 5.5 0.625 14.5 54.2 55 69.4 27.6 42.4 4.7
587 4-6 23 25 28 36 10 4 8.25 1* 14.5 54.2 55 72.2 27.6 42.4 4.7
688 2 27 - 32 36 11.5 3.125 6.5 0.75 17 54.2 59.1 72.7 33.1 45.5 5.9
688 4-8 27 - 32 36 11.5 4.375 8.25 1* 17 54.2 59.1 74.4 33.1 45.5 5.9
689 2 27 40 - - 11.5 3.125 6.5 0.75 17 54.2 59.1 79 33.1 51.8 5.9
689 4-8 27 40 - - 11.5 4.375 8.25 1* 17 54.2 59.1 80.7 33.1 51.8 5.9
728 2 32 36 - - 16 3.125 6.5 0.75 18 57.7 64.7 84.3 37.4 55.9 6.3
728 4-8 32 36 - - 16 4.375 8.25 1* 18 57.7 64.7 86.1 37.4 55.9 6.3

Motor Poles G P K H R AB OE BSX FDX CX


size
506AT
506AT
2
4-6
1.7
1.7
25.7
25.7
13.2
13.2
1.26
1.26
2.148
3.007
33.6
33.6
11.8
11.8
14
15
41.5
42.5
4.5
4.5
7
587 2 2.3 29.4 17.6 1.38 2.402 36.3 15.4 15.7 51.5 9.8
587 4-6 2.3 29.4 17.6 1.38 3.436 36.3 15.4 18.4 54.3 5.1
688 2 3 32.8 15.8 1.38 2.704 36.3 19.6 17.8 53.3 11.8
688 4-8 3 32.8 15.8 1.38 3.817 36.3 19.6 19.6 55 7.9
689 2 1 32.8 16.2 1.38 2.704 36.3 19.6 18.6 59.6 11.8
689 4-8 3 32.8 16.2 1.38 3.817 36.3 19.6 20.4 61.3 7.9
728 2 1.2 37 17.7 1.65 2.704 37.6 25.2 18.9 63 11.8
728 4-8 3.5 37 17.7 1.65 3.817 37.6 25.2 20.7 64.9 7.9

Tolerances: Above table gives the main dimensions in inches.


U +0 -0.001 F* +0 -0.003
For detailed drawings please see our web-pages
F +0 - 0.0025 D +0 -0.06 'www.abb.com/motors&generators' or contact us.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 291


NEMA Non-sparking HV Cast iron motors Sizes 506AT-728
Dimension drawings
Type I, Foot- and ange-mounted motors, IM B35 (IM 2001)

Motor Poles 2E 2F 2F' 2F'' BA U N-W F D FP O C A B J G


size
506AT 2 20 20 22 28 8.5 2.5 5.5 0.625 12.5 47.9 38.2 58.7 23.2 33.5 3.2 1.7
506AT 4-6 20 20 22 28 8.5 3.5 6.5 0.875* 12.5 47.9 38.2 59.7 23.2 33.5 3.2 1.7
587 2 23 25 28 36 10 2.75 5.5 0.625 14.5 53.4 41.9 69.4 27.6 42.4 4.7 2.3
587 4-6 23 25 28 36 10 4 8.25 1* 14.5 53.4 41.9 72.2 27.6 42.4 4.7 2.3
688 2 27 - 32 36 11.5 3.125 6.5 0.75 17 53.4 46.1 72.7 33.1 45.5 5.9 3
688 4-8 27 - 32 36 11.5 4.375 8.25 1* 17 53.4 46.1 74.4 33.1 45.5 5.9 3
689 2 27 40 - - 11.5 3.125 6.5 0.75 17 53.4 46.1 79 33.1 51.8 5.9 1
689 4-8 27 40 - - 11.5 4.375 8.25 1* 17 53.4 46.1 80.7 33.1 51.8 5.9 3
728 2 32 36 - - 16 3.125 6.5 0.75 18 56.9 51.7 84.3 37.4 55.9 6.3 1.2
728 4-8 32 36 - - 16 4.375 8.25 1* 18 56.9 51.7 86.1 37.4 55.9 6.3 3.5

7 Motor
size
Poles P K H R AB OE BSX FDX CX BE CB AJ AK BD BF BB

506AT 2 25.7 13.2 1.26 2.148 32.7 14.4 14 41.5 4.5 0.98 53.2 23.6 21.654 26 0.91 0.24
506AT 4-6 25.7 13.2 1.26 3.007 32.7 14.4 15 42.5 4.5 0.98 53.2 23.6 21.654 26 0.91 0.24
587 2 29.4 17.6 1.38 2.402 35.5 18.1 15.7 51.5 5.1 0.98 64.0 29.1 26.772 31.5 0.91 0.24
587 4-6 29.4 17.6 1.38 3.436 35.5 18.1 18.4 54.3 5.1 0.98 64.0 29.1 26.772 31.5 0.91 0.24
688 2 32.8 15.8 1.38 2.704 35.5 22.2 17.8 53.3 11.8 1.02 66.2 37 34.646 39.37 1.1 0.24
688 4-8 32.8 15.8 1.38 3.817 35.5 22.2 19.6 55 5.9 1.02 66.2 37 34.646 39.37 1.1 0.24
689 2 32.8 16.2 1.38 2.704 35.5 22.2 18.6 59.6 11.8 1.02 72.5 37 34.646 39.37 1.1 0.24
689 4-8 32.8 16.2 1.38 3.817 35.5 22.2 20.4 61.3 7.9 1.02 72.5 37 34.646 39.37 1.1 0.24
728 2 37 17.7 1.65 2.704 37 27.8 18.9 63.1 11.8 1.3 77.9 42.52 39.37 45.3 1.1 0.24
728 4-8 37 17.7 1.65 3.817 37 27.8 20.7 64.9 7.9 1.3 77.9 42.52 39.37 45.3 1.1 0.24

Tolerances: Above table gives the main dimensions in inches.


U +0 -0.001 F* +0 -0.003
For detailed drawings please see our web-pages
F +0 - 0.0025 D +0 -0.06 'www.abb.com/motors&generators' or contact us.

292 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Accessories
Provision for vibration sensors

Provision for vibration sensors M8x1. XYZ-directions. Available only for D-end.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 293


NEMA Non-sparking HV cast iron motor construction

Typical exploded view of high voltage cast iron motor

1 Stator frame 17 Valve disc with labyrinth seal, N-end


2 End shield, D-end 18 Bearing, N-end
3 Screws for end shield, D-end 19 Inner bearing cover, N-end
4 End shield, N-end 20 Spring

7 5
6
7
Screws for end shield, N-end
Rotor with shaft
Key, D-end
21
22
23
Screws for bearing cover, N-end
Fan
Fan cover
8 Main terminal box 24 Screws for fan cover
9 Middle box 25 Rating plate
10 Screws for terminal box cover 26 Lubrication plate
11 Outer bearing cover, D-end 27 Auxiliary terminal box
12 Valve disc with labyrinth seal, D-end 28 Grease nipple, D-end
13 Bearing, D-end 29 Grease nipple, N-end
14 Inner bearing cover 30 SPM nipple, D-end
15 Screws for bearing cover, D-end 31 SPM nipple, N-end
16 Outer bearing cover, N-end 32 Additional identication plate

294 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


NEMA Non-sparking HV cast iron motors in brief, basic design
Motor size 506AT 587 68_ 728

Stator Material Cast iron EN-GJL-250 EN 1561


Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy paint, thickness 180 m
Bearing end shields Material Cast iron EN-GJL-200 SFS-EN 1561
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy paint, thickness 180 m
Bearings D-end 2 pole 6316M/C3 6316M/C3 6317M/C3 6317M/C3
4-8 pole 6319/C3 6322/C3 6324/C3 6326M/C3
N-end 2 pole 6316M/C3 6316M/C3 6317M/C3 6317M/C3
4-8 pole 6316/C3 6316/C3 6319/C3 6322/C3
Axially-locked Inner bearing cover As standard, locked at D-end
bearings
Bearing seal As standard, labyrinth seal in both ends.
Lubrication Regreasable bearings
Regreasing nipples M10x1 DIN 71412 A
SPM-nipples As standard
Rating and Material Stainless steel, EN 10088, thickness 0.5 mm (0.02 ").
lubrication plate
Terminal box Frame material Structural steel S235JRG2-EN-10025, thickness 3 mm (0.12").
Cover material Structural steel S235JRG2-EN-10025, thickness 3 mm (0.12").
Cover screws material Blue passivated.
Connections Cable entries Blind gland plate.
Terminals 3 terminals for connection with cable lugs (not included)
Grounding locations on frame and terminal box (in- and outside)
Fan Material Glass reinforced polypropylene, aluminum, steel or glass reinforced polyamide fan with
metal hub.
Direction of rotation / fans (IC411)
- glass reinforced polypropylene bidirectional
- aluminum birectional
- steel bidirectional
- glass reinforced polyamide fan unidirectional.
Fan cover Material Steel
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy polyester powder, thickness 80 m
Stator winding Material Form wound copper, VPI
Insulation Insulation class F
Winding protection PT100, 6 pieces
Rotor winding Material Pressure die-cast aluminum
Balancing method Half key balancing as standard
Key ways Open key way
Heating elements On request 1x200 W 1x200 W 1x300 W 1x400 W
Drain holes
Enclosure
Standard, open on delivery.
IP 55, higher protection as option.
7
Cooling method TEFC / IC 411

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 295


7

296 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Division 2 / Zone 2
Engineered Motors
Squirrel cage three phase high voltage motors,
Up to 4500 HP

www.abb.com/motors&generators
> Motors
>> Motors and Generators for Hazardous Areas
7

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 297


Contents Page
General information 299
Enclosure and cooling 301
Type designation 303
Frame sizes 303
Notes 304
Technical data 305
Technical data, HXR cast iron motors 305
Technical data, modular motors 311
Dimension drawings, engineered motors, HXR, TEFC 317
Dimension drawings, engineered motors, HXR, TEFC, vertical 323
Dimension drawings, engineered motors, AMA, WPII 324
Dimension drawings, engineered motors, AMA, TEAAC 326
Dimension drawings, engineered motors, AMA, TEWAC 328
Dimension drawings, engineered motors, AMA, WPII, vertical 330
Dimension drawings, engineered motors, AMA, TEAAC, vertical 331
Dimension drawings, engineered motors, AMA, TEWAC, vertical 332
NEMA type II terminal box 333

ABB reserves the right to change the design,


technical specication and dimensions
without prior notice.

298 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


General information
ABB's engineered motors are tailor-made to meet the shaft heights are 400 to 500 mm (NEMA frames 68xx to
customers' needs. This description contains information 80xx).
on ABBs squirrel cage induction motors 60 Hz, with
HXR motors can be used for both standard and special
synchronous speed from 720 to 3600 rpm. The output
applications. They can also be operated on adjustable
range is from 150 HP to 4500 HP.
speed drives or used as induction generators. The
There are two different motor type described in this mounting can be horizontal or vertical and the standard
catalogue. AMA motor features a welded steel frame. shaft heights are from 355 to 560 mm (NEMA frames
They are available with following cooling methods WPII, 58xx to 88xx). The largest frame 560 mm (88xx) is for
TEAAC and TEWAC. HXR features a rugged cast iron horizontal mounting only.
frame. They are totally enclosed fan cooled, TEFC.
All motors are manufactured for output power, voltage
AMA motors can be used for both standard and special ranges and pole numbers indicated in table below.
applications. They can also be operated on adjustable
Higher voltage, speed and power ratings are available
speed drives or used as induction generators. The
on request. Please contact ABB for further information.
mounting can be horizontal or vertical and the standard

Output (HP) at 60 Hz Output (HP) at 60 Hz


HXR AMA
Poles 2.3 kV 4 kV 4 kV
2 150 - 1500 150 - 1500 1000 - 3500
4 150 - 3000 150 - 3000 1000 - 4500
6 150 - 3000 150 - 3000 700 - 3500
8 200 - 2500 200 - 2250 450 - 2500
10 200 - 2000 250 - 2000 350 - 1750
12 200 - 1750 200 - 1500 200 - 1250
Output ranges of ABB NEMA motors (Temperature rise class B, insulation class F). Other voltages on request.

Mounting arrangement
Standard mounting arrangements for AMA motors. Other mountings on request.

Code I: IM B3 Code I: IM V1
Code II: IM 1001 Code II: IM 4011
Horizontal foot mounted Vertical ange mounted
(free shaft end facing downwards)

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 299


Standard mounting arrangements for HXR motors:

Code I: IM B3 Code I: IM V1
Code II: IM 1001 Code II: IM 3011
Standard oor mounting, feet facing downwards Flange and free shaft end facing downwards
(Horizontal foot mounted) (Vertical solid shaft, ange mounted)

300 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Enclosure and cooling
Standard combinations used for AMA-motors are:

WPII (IP24W)
The weather protected motor has a shaft mounted
inside fan using the surrounding air for cooling. Motor is
so designed that the ingress of rain, snow and airborne
particles into the electrical parts is reduced. The air
intake path provides an area of average velocity not
exceeding 3 m/s, enabling any particles to settle. Also
the air intake path provides three abrupt 90 changes
in the direction of the air intake. The motor is protected
against splashing water from any direction.

TEAAC (IP55)
The motor is totally enclosed having a motor-mounted
air-to-air heat exchanger. The motor has shaft mounted
inside and outside fans to move air in the inside and
outside cooling circuits respectively. Motor is dust
protected and protected against splashing water from
any direction.

TEWAC (IP55)
The motor is totally enclosed having a motor-mounted
air-to-water heat exchanger. The motor has a shaft
mounted inside fan to move air in the inside cooling
circuit. Motor is dust protected and protected against
7
splashing water from any direction.

The terminal boxes always have a protection of at least


IP55.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 301


Standard designs for AMA-motors are: Available as options are:
- Weather-protected motor TYPE II (WPII) acc. to - Washable reusable lters for the weather-protected
NEMA MG1 - 1.25.8.2. The corresponding AMA motor IC01 IP23/IPW24. The lter material is
design acc. to IEC 34 is IC01 IPW24. normally stainless steel.
- Totally-enclosed water-air-cooled motor (TEWAC) - Motor with long connecting cables without main
acc. to NEMA MG1 - 1.26.8. The corresponding AMA terminal box.
design acc. to IEC 34 is IC81W IP55.
- Totally-enclosed air-to-air-cooled motor (TEAAC) acc.
to NEMA MG1 - 1.26.9. The corresponding AMA
design acc. to IEC 34 is IC611 IP55.

TEFC (IP55) HXR motor


The HXR motor has an external shaft mounted fan against dust and water jets. The principle is shown in
using the surrounding air for cooling. Motor is protected below:

Sectional drawing of TEFC / IP55 motor.

Protection denition IP55 Method of Cooling (TEFC)


Dust-protected motor: Frame surface cooled:
Ingress of dust is not totally prevented but dust does not The primary coolant is circulated in a closed circuit
enter in sufcient quantity to interfere with satisfactory in the motor and gives its heat through the external

7 operation of the motor.


Motor protected against water jets:
surface of the motor (in addition to the heat transfer
via the stator core and other heat conducting parts) to
the nal coolant which is the surrounding medium. The
Water projected by a nozzle against the motor from any
surface may be plain or ribbed, with or without an outer
direction shall have no harmful effect.
shell to improve the heat transfer.
Self circulation:
The coolant is moved dependent on the rotational
speed of the main motor, either by action of the rotor
alone or by means of a component designed for this
purpose and mounted directly on the rotor of the main
motor, or by a fan or pump unit mechanically driven by
the rotor or the main motor.

302 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Type designation
The type designation of the AMA motor follows the coding principle shown below.

Example: AMA 450L4A BATH


1 AM Stands for Alternating Current Machines
2 A Indicates the type of machine, A - E = SCIM, K - P = WRIM
3 450 Frame size in mm, 400, 450 or 500
4 L Frame length, S = small, M = medium or L = long
5 4 Number of poles
6 A Stands for the IC/IP combination
L = IC81W / IP54 (55) [TEWAC]
W = IC01 / IPW24 [WP II] A = IC611 / IP54 (55) [TEAAC]
7 B Mounting arrangement, B = IM1001 (Horizontal), V = IM4011 (Vertical)
8 A Bearing type, A = antifriction, S = sleeve
9 T Indication of special construction
T = separate ventilation X = electrically special
N = Non-sparking design F = frequency converter drive Y = mechanically special
10 H Location of manufacture

The type designation of the HXR motor follows the coding principle shown below.

Example: HXR 355LA4


1. HXR Stands for the HXR machine family, three digits.
2. 355 Shaft height in mm, three digits.
3. L Frame length, one digit.
4. A Core length, one digit.
5. 4 Number of poles.

Frame sizes
IEC Equivalent to NEMA series*
355 58xx
400 68xx
450 72xx
500 80xx
560
* NEMA frames are for reference only.
88xx 7

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 303


Notes
All ratings in this catalogue are designed for the
following:
- Horizontal mounting
- 3 phase
- Class F insulation
- Service factor of 1.0
- Maximum temperature rise of 80 degrees C by
resistance at 1.0 service factor
- Maximum 104 degrees F (40 degrees C) ambient
- Altitude of 3300 feet or less

304 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 HXR Cast iron motors 2300 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEFC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

2300 V 60 Hz
150 3600 HXR 355LA2 3571 91.9 90.9 0.89 0.87 34 651 G 11 221 68 291 3483 89
150 1800 HXR 355LA4 1785 92.9 92.1 0.81 0.77 37 610 G 16 441 100 242 3505 82
150 1200 HXR 355LA6 1189 93.0 92.4 0.77 0.72 39 523 F 19 663 95 212 3483 80
200 3600 HXR 355LA2 3570 93.0 92.3 0.90 0.88 45 668 G 13 294 70 289 3483 89
200 1800 HXR 355LA4 1786 93.8 93.3 0.84 0.80 48 631 G 19 588 98 237 3682 82
200 1200 HXR 355LA6 1189 93.7 93.3 0.78 0.73 51 539 F 24 884 102 211 3704 80
200 900 HXR 400LA8 891 93.9 93.8 0.77 0.72 52 490 F 24 1179 91 197 5027 75
200 720 HXR 400LB10 714 93.6 93.1 0.69 0.63 58 466 F 33 1471 83 200 5445 79
200 600 HXR 400LC12 594 93.3 93.0 0.68 0.62 59 420 E 34 1770 93 178 5732 75
250 3600 HXR 355LA2 3570 93.6 93.0 0.89 0.87 56 670 G 17 368 71 289 3483 89
250 1800 HXR 355LA4 1786 94.3 93.9 0.85 0.82 58 643 G 21 735 97 240 3704 82
250 1200 HXR 355LA6 1190 94.1 93.8 0.78 0.73 63 541 F 30 1104 92 213 3682 80
250 900 HXR 400LA8 891 94.2 94.3 0.80 0.76 62 508 F 26 1474 88 202 5137 75
250 720 HXR 400LC10 714 93.9 93.6 0.72 0.66 69 465 F 37 1841 87 189 5732 79
250 600 HXR 400LE12 594 93.5 93.3 0.69 0.63 73 426 E 41 2212 95 178 6261 75
300 3600 HXR 355LA2 3569 94.1 93.8 0.91 0.89 66 666 G 17 442 73 279 3704 89
300 1800 HXR 355LA4 1786 94.6 94.3 0.85 0.82 70 635 G 25 883 98 231 3704 82
300 1200 HXR 355LB6 1190 94.6 94.4 0.80 0.75 74 547 F 32 1325 96 206 3858 80
300 900 HXR 400LB8 891 94.5 94.6 0.81 0.77 73 505 E 30 1768 88 198 5445 75
300 720 HXR 400LD10 714 94.1 93.9 0.72 0.66 83 467 F 43 2209 89 189 6019 79
300 600 HXR 400LG12 594 93.8 93.6 0.69 0.63 86 428 E 47 2655 95 177 6834 75
350 3600 HXR 355LB2 3570 94.5 94.3 0.91 0.89 76 656 G 20 515 71 268 3902 89
350 1800 HXR 355LB4 1786 94.9 94.7 0.86 0.83 81 661 G 28 1029 105 233 3902 82
350 1200 HXR 355LC6 1189 94.9 94.8 0.81 0.78 85 534 F 34 1547 95 198 4101 80
350 900 HXR 400LC8 891 94.8 94.9 0.82 0.78 85 501 E 33 2064 90 194 5600 75
350 720 HXR 400LF10 714 94.3 94.1 0.72 0.66 97 467 F 51 2576 87 186 6460 79
350 600 HXR 450LF12 595 94.3 94.0 0.70 0.64 99 438 E 54 3093 85 182 8576 75
400 3600 HXR 355LC2 3571 94.8 94.7 0.92 0.91 86 655 G 20 589 68 265 4079 89
400 1800 HXR 355LC4 1786 95.2 95.0 0.86 0.83 92 656 G 31 1177 106 227 4034 82
400 1200 HXR 355LD6 1189 95.1 95.1 0.82 0.78 97 528 F 38 1768 95 194 4211 80
400 900 HXR 400LC8 891 94.8 95.0 0.82 0.78 97 500 E 37 2359 91 193 5710 75
400 720 HXR 400LH10 714 94.3 94.0 0.72 0.66 111 473 F 59 2943 87 190 7121 79
400
450
450
600
3600
1800
HXR 450LG12
HXR 355LD2
HXR 355LD4
595
3571
1786
94.4
95.0
95.3
94.2
95.0
95.3
0.70
0.92
0.87
0.64
0.90
0.84
113
97
102
433
636
637
E
F
G
60
22
32
3535
662
1324
84
65
103
178
258
218
8951
4189
4233
75
89
82
7
450 1200 HXR 355LE6 1189 95.2 95.2 0.82 0.78 108 539 F 41 1988 98 191 4497 80
450 900 HXR 400LE8 892 95.1 95.2 0.81 0.77 109 517 F 45 2650 90 199 6283 75
450 720 HXR 400LK10 714 94.4 94.1 0.72 0.66 123 489 F 65 3310 93 195 7562 79
450 600 HXR 450LH12 594 94.6 94.4 0.71 0.65 125 431 E 66 3977 83 176 9480 75

IEC frame size NEMA frame size


355 58xx
Data presented in rating lists are typical values.
400 68xx Guaranteed values on request. All engineered motors
450 72xx are optimized for the specied application. Accurate
500 80xx motor data will be given on request at quotation phase.
Legally binding performance and specication data is
560 88xx
given to the end user once each order is conrmed.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 305


Class I Div/Zone 2 HXR Cast iron motors 2300 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEFC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

2300 V 60 Hz
500 3600 HXR 355LD2 3577 95.2 95.1 0.90 0.88 109 692 G 30 734 63 285 4277 89
500 1800 HXR 355LE4 1786 95.5 95.5 0.87 0.84 113 629 G 35 1471 101 213 4453 82
500 1200 HXR 355LF6 1189 95.3 95.3 0.82 0.79 120 548 F 46 2209 101 195 4718 80
500 900 HXR 400LG8 892 95.3 95.4 0.81 0.77 121 527 F 49 2944 93 202 6702 75
500 720 HXR 450LF10 714 95.5 95.6 0.76 0.71 129 506 F 62 3678 91 200 8554 76
500 600 HXR 450LK12 595 94.7 94.5 0.71 0.66 138 433 E 72 4419 84 176 10207 75
600 3600 HXR 400LE2 3579 95.3 95.1 0.92 0.91 128 696 G 28 881 69 274 6107 88
600 1800 HXR 400LC4 1789 95.8 95.7 0.87 0.84 135 634 G 43 1763 90 220 5842 80
600 1200 HXR 400LE6 1191 95.6 95.6 0.83 0.80 141 574 F 52 2647 88 202 6305 79
600 900 HXR 400LH8 892 95.2 95.3 0.82 0.78 145 522 F 57 3533 93 197 7143 75
600 720 HXR 450LH10 714 95.7 95.8 0.77 0.72 153 501 F 71 4415 90 195 9259 76
600 600 HXR 500LH12 595 95.0 94.8 0.71 0.65 167 455 F 88 5299 85 189 12919 75
700 3600 HXR 400LF2 3578 95.6 95.5 0.93 0.92 148 661 F 30 1028 66 259 6504 88
700 1800 HXR 400LD4 1789 96.0 96.0 0.87 0.85 156 627 F 47 2056 91 213 6129 80
700 1200 HXR 400LG6 1191 95.7 95.8 0.84 0.81 163 586 F 57 3089 94 202 6724 79
700 900 HXR 450LG8 894 95.7 95.6 0.82 0.78 167 586 F 67 4114 90 219 9083 76
700 720 HXR 450LK10 714 95.8 95.9 0.76 0.71 180 513 F 85 5148 92 198 10119 76
700 600 HXR 500LK12 595 95.1 94.9 0.71 0.65 194 460 F 102 6181 87 190 13801 75
800 3600 HXR 400LH2 3583 95.8 95.7 0.92 0.90 171 717 G 40 1174 63 282 6878 88
800 1800 HXR 400LF4 1789 96.2 96.2 0.88 0.87 176 623 F 48 2350 95 208 6702 80
800 1200 HXR 400LJ6 1191 95.9 96.0 0.85 0.82 184 566 F 60 3530 91 195 7430 79
800 900 HXR 450LJ8 894 95.8 95.7 0.81 0.77 192 600 G 81 4699 90 225 9789 76
800 720 HXR 450LM10 715 95.7 95.7 0.76 0.71 206 520 F 98 5882 94 200 10825 76
800 600 HXR 500LL12 595 95.1 94.9 0.72 0.66 220 450 E 113 7066 86 184 14242 75
900 3600 HXR 450LH2 3585 95.7 95.4 0.91 0.89 194 725 G 52 1319 57 290 9370 91
900 1800 HXR 400LH4 1789 96.3 96.4 0.88 0.87 198 635 F 53 2643 99 207 7187 80
900 1200 HXR 450LE6 1192 96.1 96.3 0.88 0.86 199 576 F 54 3968 90 198 8466 80
900 900 HXR 450LL8 895 96.0 95.9 0.81 0.77 215 588 G 87 5282 91 211 10516 76
900 720 HXR 500LJ10 715 96.1 96.2 0.78 0.74 223 511 F 97 6617 84 196 13360 78
900 600 HXR 500LN12 595 95.1 94.9 0.72 0.66 247 456 E 128 7948 87 186 15080 75
1000 3600 HXR 500LJ2 3585 95.7 95.4 0.92 0.91 212 714 G 52 1466 56 296 13360 91
1000 1800 HXR 450LG4 1790 96.3 96.3 0.89 0.87 219 669 G 60 2935 97 230 9215 82

7 1000
1000
1000
1200
900
720
HXR 450LJ6
HXR 450LN8
HXR 500LL10
1193
895
715
96.3
96.1
96.1
96.5
96.0
96.3
0.88
0.82
0.79
0.86
0.78
0.75
221
239
246
608
590
504
F
G
E
62
96
104
4404
5868
7353
93
91
83
208
211
192
9722
11244
14021
80
76
78
1000 600 HXR 500LQ12 595 95.2 95.1 0.72 0.67 271 438 E 134 8836 83 177 15741 75

IEC frame size NEMA frame size


355 58xx Data presented in rating lists are typical values.
400 68xx Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
450 72xx
motor data will be given on request at quotation phase.
500 80xx Legally binding performance and specication data is
560 88xx given to the end user once each order is conrmed.

306 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 HXR Cast iron motors 2300 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEFC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

2300 V 60 Hz
1250 3600 HXR 500LM2 3586 96.1 95.9 0.92 0.91 264 711 G 61 1832 57 279 14617 91
1250 1800 HXR 450LL4 1791 96.5 96.6 0.89 0.87 272 673 G 73 3667 98 224 10648 82
1250 1200 HXR 500LG6 1194 96.5 96.6 0.86 0.84 280 612 F 90 5501 82 218 12588 82
1250 900 HXR 500LM8 895 96.2 96.1 0.83 0.79 293 608 G 114 7340 86 221 14617 77
1250 720 HXR 500LP10 715 96.2 96.3 0.79 0.75 307 506 E 127 9192 85 187 15565 78
1250 600 HXR 560LM12 596 96.0 96.0 0.77 0.71 318 473 E 149 11013 68 197 21539 76
1500 3600 HXR 500LQ2 3587 96.3 96.1 0.91 0.89 320 728 G 82 2197 54 277 15829 91
1500 1800 HXR 500LJ4 1792 96.6 96.7 0.90 0.88 323 687 G 86 4398 85 245 13580 82
1500 1200 HXR 500LK6 1194 96.7 96.8 0.87 0.85 332 641 G 102 6599 83 225 13580 82
1500 900 HXR 500LS8 896 96.4 96.4 0.84 0.80 348 607 G 129 8799 90 213 17042 77
1500 720 HXR 500LS10 715 96.2 96.2 0.79 0.75 369 534 F 159 11018 83 197 17086 78
1500 600 HXR 560LR12 596 96.1 96.0 0.76 0.70 386 506 F 192 13215 75 212 23656 76
1750 1800 HXR 500LM4 1792 96.8 96.9 0.91 0.89 374 661 G 90 5132 86 232 14881 82
1750 1200 HXR 500LM6 1195 96.8 96.9 0.87 0.85 388 656 G 122 7696 84 229 14661 82
1750 900 HXR 560LM8 896 96.7 96.8 0.82 0.79 411 568 F 159 10258 72 209 21627 80
1750 720 HXR 560LP10 717 96.4 96.4 0.78 0.73 438 509 F 194 12827 69 187 22774 80
1750 600 HXR 560LU12 597 96.3 96.3 0.77 0.73 441 463 E 195 15402 67 183 26698 76
2000 1800 HXR 500LP4 1792 96.9 97.0 0.90 0.89 428 665 G 105 5864 84 229 15675 82
2000 1200 HXR 500LQ6 1194 96.9 97.1 0.88 0.86 438 639 F 124 8799 86 219 15984 82
2000 900 HXR 560LP8 897 96.8 96.9 0.81 0.77 475 614 G 191 11709 82 209 22774 80
2000 720 HXR 560LT10 717 96.5 96.5 0.78 0.73 499 540 F 225 14649 74 200 26015 80
2250 1800 HXR 560LK4 1793 96.8 96.8 0.90 0.89 482 669 G 123 6590 68 245 20723 85
2250 1200 HXR 500LS6 1196 97.0 97.1 0.86 0.83 505 688 G 171 9881 88 226 17350 82
2250 900 HXR 560LS8 897 96.9 97.0 0.82 0.78 531 607 G 207 13177 80 208 25552 80
2500 1800 HXR 560LM4 1794 96.9 96.9 0.90 0.88 538 703 G 149 7318 69 254 21826 85
2500 1200 HXR 560LR6 1195 96.9 96.9 0.88 0.85 550 666 G 168 10983 79 235 23920 85
2500 900 HXR 560LU8 897 97.0 97.1 0.83 0.79 581 621 G 228 14637 69 228 27514 80
3000 1800 HXR 560LT4 1794 97.4 97.5 0.91 0.90 633 689 G 143 8780 77 229 26301 85
3000 1200 HXR 560LU6 1196 97.4 97.4 0.89 0.87 651 622 F 167 13178 78 203 27249 85

IEC frame size NEMA frame size


355 58xx Data presented in rating lists are typical values.
Guaranteed values on request. All engineered motors
400 68xx
are optimized for the specied application. Accurate
450 72xx motor data will be given on request at quotation phase.
500 80xx Legally binding performance and specication data is
560 88xx given to the end user once each order is conrmed.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 307


Class I Div/Zone 2 HXR Cast iron motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEFC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
150 3600 HXR 355LA2 3558 91.6 90.8 0.90 0.89 20 555 E 5 222 58 256 3527 89
150 1800 HXR 355LA4 1787 93.1 92.3 0.82 0.78 21 560 F 9 441 71 238 3638 82
150 1200 HXR 355LA6 1188 93.0 92.5 0.79 0.74 22 493 F 10 664 68 225 3616 80
200 3600 HXR 355LA2 3572 92.8 92.1 0.89 0.87 26 615 F 7 294 66 257 3505 89
200 1800 HXR 355LA4 1787 93.3 92.7 0.82 0.77 28 647 H 12 588 100 245 3417 82
200 1200 HXR 355LA6 1189 93.3 93.0 0.79 0.74 29 520 F 13 884 98 202 3616 80
200 900 HXR 400LA8 890 93.7 93.7 0.78 0.73 30 459 E 13 1181 88 187 5093 75
200 600 HXR 400LD12 594 92.8 92.5 0.69 0.62 34 423 E 19 1769 91 181 5908 75
250 3600 HXR 355LA2 3568 93.2 92.8 0.90 0.88 32 655 G 9 368 71 279 3417 89
250 1800 HXR 355LA4 1785 93.7 93.4 0.83 0.79 35 638 G 14 736 104 245 3439 82
250 1200 HXR 355LA6 1187 93.7 93.6 0.79 0.75 36 513 F 15 1106 103 189 3594 80
250 900 HXR 400LB8 890 94.1 94.1 0.78 0.74 36 452 E 16 1476 87 180 5357 75
250 720 HXR 400LD10 714 93.5 93.1 0.71 0.64 41 482 F 23 1839 90 200 5776 79
250 600 HXR 400LF12 594 93.2 93.0 0.69 0.63 42 427 E 23 2212 94 179 6327 75
300 3600 HXR 355LA2 3573 93.9 93.6 0.90 0.88 38 646 G 10 441 70 260 3616 89
300 1800 HXR 355LA4 1783 94.0 93.9 0.84 0.81 41 586 F 15 884 97 221 3439 82
300 1200 HXR 355LB6 1187 94.1 94.0 0.80 0.76 43 513 F 18 1328 104 185 3814 80
300 900 HXR 400LD8 890 94.4 94.5 0.78 0.74 44 457 E 19 1770 87 180 5776 75
300 720 HXR 400LD10 714 93.5 93.3 0.72 0.66 48 476 F 26 2208 91 194 5908 79
300 600 HXR 400LH12 594 93.5 93.2 0.69 0.62 50 429 E 28 2653 93 181 7033 75
350 3600 HXR 355LB2 3571 94.3 94.2 0.91 0.90 44 607 F 10 515 68 239 3814 89
350 1800 HXR 355LA4 1786 94.6 94.4 0.85 0.81 47 646 G 17 1030 102 240 3638 82
350 1200 HXR 355LC6 1190 94.6 94.6 0.80 0.76 50 523 F 21 1546 89 198 4057 80
350 900 HXR 400LE8 890 94.6 94.7 0.79 0.76 50 458 E 21 2066 91 179 6063 75
350 720 HXR 400LF10 714 93.9 93.5 0.72 0.65 56 483 F 30 2575 91 193 6482 79
350 600 HXR 450LG12 595 94.1 93.8 0.70 0.63 58 437 E 32 3091 82 185 8841 75
400 3600 HXR 355LC2 3570 94.6 94.5 0.90 0.89 50 612 F 12 589 64 241 4034 89
400 1800 HXR 355LB4 1786 94.8 94.7 0.85 0.82 54 635 G 19 1177 100 228 3748 82
400 1200 HXR 355LD6 1189 94.8 94.8 0.81 0.78 56 535 F 22 1767 95 197 4255 80
400 900 HXR 400LG8 891 94.7 94.8 0.79 0.75 58 465 E 24 2359 89 181 6570 75
400 720 HXR 400LH10 714 94.1 93.8 0.73 0.67 63 487 F 33 2944 94 194 6900 79
400 600 HXR 450LH12 595 94.3 94.0 0.70 0.64 65 438 E 36 3533 82 184 9370 75

7 450
450
450
3600
1800
1200
HXR 355LD2
HXR 355LC4
HXR 355LE6
3573
1788
1190
94.9
95.1
95.0
94.9
95.1
95.0
0.92
0.85
0.82
0.90
0.82
0.78
56
60
63
654
631
542
G
G
F
13
21
25
662
1323
1988
66
103
97
261
210
198
4233
3990
4475
89
82
80
450 900 HXR 400LH8 891 94.9 95.1 0.79 0.76 64 459 E 26 2655 90 176 6900 75
450 720 HXR 400LK10 714 94.2 94.0 0.74 0.68 70 484 F 35 3312 93 191 7452 79
450 600 HXR 450LK12 595 94.4 94.1 0.70 0.64 73 448 F 41 3973 85 188 10075 75

IEC frame size NEMA frame size


355 58xx
Data presented in rating lists are typical values.
400 68xx Guaranteed values on request. All engineered motors
450 72xx are optimized for the specied application. Accurate
500 80xx motor data will be given on request at quotation phase.
560 88xx Legally binding performance and specication data is
given to the end user once each order is conrmed.

308 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 HXR Cast iron motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEFC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
500 3600 HXR 400LD2 3581 94.9 94.5 0.90 0.89 63 695 G 16 734 61 276 5886 88
500 1800 HXR 355LD4 1788 95.3 95.3 0.85 0.82 66 634 G 23 1469 103 208 4189 82
500 1200 HXR 400LD6 1191 95.5 95.4 0.83 0.79 68 589 F 26 2206 95 216 5975 79
500 900 HXR 400LH8 891 94.7 94.8 0.79 0.76 72 463 E 29 2950 92 178 6989 78
500 720 HXR 450LF10 714 95.2 95.4 0.77 0.72 74 513 F 35 3679 93 201 8576 76
500 600 HXR 450LN12 595 94.5 94.1 0.69 0.63 82 447 F 46 4413 82 191 11133 75
600 3600 HXR 400LE2 3581 95.3 95.0 0.91 0.89 75 701 G 19 880 64 269 6173 88
600 1200 HXR 400LE6 1191 95.6 95.6 0.84 0.80 81 577 F 30 2648 94 208 6217 79
600 1800 HXR 400LC4 1790 95.8 95.7 0.87 0.85 77 625 F 24 1763 81 223 5820 80
600 900 HXR 450LE8 893 95.3 95.3 0.83 0.80 81 571 F 31 3529 94 212 8289 76
600 720 HXR 450LH10 714 95.4 95.6 0.76 0.71 89 521 F 43 4413 95 204 9281 76
600 600 HXR 500LJ12 595 94.6 94.4 0.72 0.66 95 447 E 48 5302 86 182 13250 75
700 3600 HXR 400LG2 3582 95.6 95.4 0.91 0.89 87 705 G 21 1026 65 265 6548 88
700 1800 HXR 400LE4 1790 96.0 96.1 0.88 0.87 89 637 F 25 2055 88 220 6217 80
700 1200 HXR 400LH6 1192 95.8 95.8 0.83 0.79 95 593 F 36 3087 94 213 6923 79
700 900 HXR 450LG8 893 95.3 95.2 0.84 0.80 95 566 F 35 4117 93 212 8995 76
700 720 HXR 450LK10 714 95.3 95.4 0.77 0.72 103 506 F 47 5150 92 196 9811 76
700 600 HXR 500LM12 595 94.6 94.3 0.71 0.66 111 449 E 58 6183 86 183 14330 75
800 3600 HXR 450LG2 3584 95.5 95.2 0.91 0.90 99 705 G 24 1173 64 279 8929 91
800 1800 HXR 400LF4 1790 96.1 96.2 0.89 0.87 101 638 F 28 2348 87 217 6570 80
800 1200 HXR 450LE6 1192 96.0 96.1 0.88 0.86 102 598 F 29 3526 92 207 8378 80
800 900 HXR 450LH8 893 95.4 95.4 0.84 0.81 107 567 F 38 4706 95 206 9348 76
800 720 HXR 450LM10 714 95.4 95.6 0.77 0.73 117 504 F 53 5886 92 194 10516 76
800 600 HXR 500LP12 595 94.7 94.5 0.72 0.67 126 434 E 62 7070 82 173 15190 75
900 3600 HXR 450LK2 3582 95.7 95.5 0.93 0.92 109 686 G 23 1320 60 275 9766 91
900 1800 HXR 400LH4 1791 96.3 96.3 0.88 0.85 115 639 G 34 2639 82 219 7011 80
900 1200 HXR 450LG6 1193 96.1 96.2 0.87 0.85 115 620 F 35 3963 92 214 9039 80
900 900 HXR 450LM8 894 95.6 95.6 0.84 0.81 120 573 F 43 5292 93 217 10759 76
900 720 HXR 500LL10 715 95.9 96.0 0.79 0.75 128 515 F 55 6617 86 200 13911 78
900 600 HXR 500LR12 595 94.8 94.6 0.73 0.68 140 448 E 69 7953 88 179 16072 75
1000 3600 HXR 500LH2 3588 95.8 95.4 0.91 0.89 124 727 G 32 1464 56 289 12831 91
1000 1800 HXR 450LH4 1791 96.2 96.3 0.89 0.88 125 647 G 33 2933 83 227 9480 82
1000
1000
1000
1200
900
720
HXR 450LJ6
HXR 500LL8
HXR 500LN10
1193
895
715
96.2
96.1
96.0
96.4
96.0
96.1
0.88
0.83
0.79
0.86
0.80
0.74
127
134
142
610
586
518
F
F
F
36
50
62
4404
5868
7350
91
86
85
210
210
200
9744
13955
14991
80
77
78
7
1000 600 HXR 560LJ12 596 95.7 95.7 0.76 0.71 148 472 E 71 8815 67 199 19643 76

IEC frame size NEMA frame size


355 58xx
Data presented in rating lists are typical values.
400 68xx Guaranteed values on request. All engineered motors
450 72xx are optimized for the specied application. Accurate
500 80xx motor data will be given on request at quotation phase.
560 88xx Legally binding performance and specication data is
given to the end user once each order is conrmed.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 309


Class I Div/Zone 2 HXR Cast iron motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEFC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
1250 3600 HXR 500LM2 3587 96.1 95.9 0.93 0.92 151 711 G 33 1831 60 279 14462 91
1250 1800 HXR 450LL4 1791 96.5 96.6 0.89 0.88 156 644 F 40 3666 83 221 10362 82
1250 1200 HXR 500LG6 1194 96.4 96.5 0.86 0.83 162 611 F 53 5501 82 217 12434 82
1250 900 HXR 500LN8 896 96.2 96.2 0.83 0.80 168 599 F 63 7334 90 212 14947 77
1250 720 HXR 500LR10 715 95.9 96.0 0.80 0.76 176 510 E 72 9192 86 195 16204 78
1250 600 HXR 560LN12 597 95.9 95.9 0.76 0.71 184 464 E 86 11000 67 186 21760 76
1500 3600 HXR 500LQ2 3589 96.4 96.2 0.91 0.90 183 742 G 44 2196 60 278 15454 91
1500 1800 HXR 500LJ4 1792 96.5 96.6 0.89 0.88 187 646 F 50 4399 77 232 13140 82
1500 1200 HXR 500LK6 1194 96.5 96.7 0.87 0.85 192 614 F 59 6602 85 213 13735 82
1500 900 HXR 500LS8 896 96.3 96.3 0.83 0.80 202 601 G 76 8798 88 214 17108 77
1500 720 HXR 560LM10 715 96.1 96.1 0.79 0.75 213 485 E 89 11020 69 183 21363 80
1500 600 HXR 560LS12 597 96.1 96.1 0.77 0.72 219 475 E 100 13204 69 190 25111 76
1750 1800 HXR 500LL4 1792 96.7 96.8 0.90 0.88 217 637 F 56 5132 77 226 14286 82
1750 1200 HXR 500LP6 1194 96.7 96.8 0.87 0.84 225 613 F 69 7699 83 213 15454 82
1750 900 HXR 560LM8 896 96.6 96.7 0.82 0.79 236 581 F 92 10258 75 212 21451 80
1750 720 HXR 560LR10 717 96.4 96.3 0.78 0.74 250 521 F 111 12824 70 193 24097 80
2000 1800 HXR 500LR4 1793 96.9 96.9 0.89 0.87 250 641 F 69 5861 72 228 16424 82
2000 1200 HXR 560LK6 1195 96.6 96.6 0.87 0.85 255 662 G 81 8786 78 235 20437 85
2000 900 HXR 560LR8 896 96.7 96.8 0.82 0.79 270 569 F 104 11718 72 210 23634 80
2000 720 HXR 560LU10 717 96.5 96.4 0.78 0.74 285 535 F 126 14649 72 199 27117 80
2250 1800 HXR 560LK4 1794 96.7 96.8 0.90 0.89 277 688 G 73 6590 70 251 20613 85
2250 1200 HXR 560LP6 1196 96.8 96.8 0.87 0.84 288 669 G 95 9885 75 240 22355 85
2250 900 HXR 560LU8 896 96.8 96.9 0.83 0.79 303 613 G 120 13184 80 225 26940 80
2500 1800 HXR 560LS4 1793 96.9 97.0 0.91 0.90 304 651 F 68 7322 70 236 24978 85
2500 1200 HXR 560LS6 1196 96.9 96.9 0.88 0.86 316 674 G 97 10981 80 239 25287 85
3000 1800 HXR 560LT4 1795 97.4 97.4 0.90 0.88 370 709 G 98 8776 70 236 25948 85
3000 1200 HXR 560LU6 1196 97.3 97.3 0.87 0.85 381 679 G 119 13168 78 223 26985 85

IEC frame size NEMA frame size


355 58xx Data presented in rating lists are typical values.
Guaranteed values on request. All engineered motors
400 68xx
are optimized for the specied application. Accurate
450 72xx motor data will be given on request at quotation phase.
500 80xx Legally binding performance and specication data is
560 88xx given to the end user once each order is conrmed.

310 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 HV Modular motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
WPII Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
250 600 AMA 400L12D 593 91.9 91.6 0.71 0.65 41 403 E 22 2211 75 184 6041 77
300 600 AMA 400L12D 593 92.1 91.7 0.69 0.62 51 406 E 29 2660 76 190 6261 77
350 600 AMA 400L12D 593 92.3 92.0 0.70 0.64 58 398 E 32 3101 74 182 6482 77
400 720 AMA 400L10D 711 93.3 93.4 0.76 0.71 61 417 D 29 2952 65 179 6063 77
400 600 AMA 400L12D 592 92.6 92.4 0.73 0.67 64 397 D 32 3543 75 177 6878 77
450 720 AMA 400L10D 711 93.4 93.6 0.77 0.72 68 419 D 31 3330 67 179 6261 77
450 600 AMA 400L12D 593 92.7 92.5 0.71 0.65 73 406 E 39 3992 77 180 7099 77
500 900 AMA 400L8D 889 94.1 94.4 0.83 0.81 68 462 D 24 2955 74 184 6063 77
500 720 AMA 400L10D 711 93.6 93.8 0.77 0.72 75 423 D 34 3696 68 175 6482 77
500 600 AMA 400L12D 593 92.8 92.5 0.71 0.64 82 411 E 45 4429 77 185 7518 77
600 900 AMA 400L8D 889 94.3 94.6 0.84 0.81 82 450 D 28 3551 73 178 6283 77
600 720 AMA 400L10D 711 93.9 94.0 0.77 0.72 90 436 E 41 4435 69 180 7099 77
600 600 AMA 450L12D 593 94.0 94.2 0.77 0.72 90 431 D 42 5319 73 184 8686 78
700 900 AMA 400L8D 889 94.5 94.8 0.83 0.80 96 469 D 34 4135 78 184 6482 77
700 720 AMA 400L10D 711 94.0 94.2 0.77 0.72 104 436 E 47 5168 70 177 7518 77
700 600 AMA 450L12D 594 94.1 94.1 0.75 0.69 107 441 E 54 6191 73 191 9171 78
800 1200 AMA 400L6D 1187 94.7 95.0 0.83 0.80 109 500 E 41 3542 73 201 6085 79
800 900 AMA 400L8D 890 94.5 94.8 0.83 0.80 109 475 D 39 4727 78 185 6856 77
800 720 AMA 450L10D 712 94.4 94.7 0.82 0.79 111 449 D 42 5908 73 181 8400 78
800 600 AMA 450L12D 594 94.2 94.3 0.76 0.71 120 440 E 58 7083 74 187 9700 78
900 1200 AMA 400L6D 1188 94.9 95.1 0.82 0.79 124 511 E 48 3979 76 204 6305 79
900 900 AMA 400L8D 889 94.6 94.9 0.83 0.81 123 477 E 44 5313 80 184 7055 77
900 720 AMA 450L10D 712 94.5 94.8 0.82 0.79 125 454 D 47 6640 75 181 8664 78
900 600 AMA 500L12D 594 94.6 94.7 0.78 0.73 132 461 E 61 7955 72 190 11133 79
1000 3600 AMA 400L2D 3579 95.5 95.6 0.89 0.87 127 598 F 34 1468 60 249 6437 85
1000 1800 AMA 400L4D 1785 95.1 95.3 0.88 0.86 129 529 E 37 2943 65 213 6283 80
1000 1200 AMA 400L6D 1188 95.1 95.3 0.83 0.80 136 518 E 51 4423 78 204 6526 79
1000 900 AMA 400L8D 889 94.7 95.1 0.84 0.82 135 473 D 45 5909 80 181 7474 77
1000 720 AMA 450L10D 712 94.6 95.0 0.83 0.80 137 458 D 49 7383 77 181 9193 78
1000 600 AMA 500L12D 594 94.7 94.9 0.79 0.74 144 456 E 63 8845 71 187 11795 79
1250 3600 AMA 400L2D 3579 95.7 95.8 0.88 0.86 160 603 F 46 1834 62 249 6614 85
1250 1800 AMA 400L4D 1785 95.3 95.6 0.88 0.86 161 519 E 45 3678 67 206 6504 80
1250
1250
1250
1200
900
720
AMA 400L6D
AMA 450L8D
AMA 500L10D
1189
892
714
95.3
95.3
95.3
95.5
95.6
95.5
0.82
0.84
0.81
0.79
0.81
0.77
172
168
173
533
507
514
F
E
E
67
60
71
5527
7361
9189
80
72
68
204
193
203
7099
8708
11486
79
78
79
7
1250 600 AMA 500L12D 595 95.0 95.0 0.78 0.73 182 475 E 84 11042 74 195 13118 79

IEC frame size NEMA frame size Data presented in rating lists are typical values.
Guaranteed values on request. All engineered motors
400 68xx are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
450 72xx
Legally binding performance and specication data is
500 80xx given to the end user once each order is conrmed.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 311


Class I Div/Zone 2 HV Modular motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
WPII Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
1500 3600 AMA 400L2D 3579 95.9 96.1 0.89 0.87 189 599 F 50 2202 60 248 6900 85
1500 1800 AMA 400L4D 1784 95.3 95.7 0.87 0.85 195 513 E 57 4417 67 204 6680 80
1500 1200 AMA 450L6D 1191 95.6 95.8 0.86 0.83 197 541 E 63 6618 65 205 8774 81
1500 900 AMA 450L8D 893 95.6 95.8 0.83 0.79 205 521 E 79 8830 72 195 9502 78
1500 720 AMA 500L10D 714 95.4 95.6 0.82 0.78 207 503 E 82 11036 67 196 12147 79
1750 3600 AMA 400L2D 3579 96.0 96.3 0.89 0.88 219 599 F 54 2568 65 243 7385 85
1750 1800 AMA 400L4D 1785 95.6 96.0 0.89 0.88 222 519 E 56 5149 65 203 7121 80
1750 1200 AMA 450L6D 1191 95.7 96.0 0.86 0.83 230 533 E 73 7726 65 202 9061 81
1750 900 AMA 500L8D 891 95.6 96.0 0.86 0.84 229 490 D 68 10311 66 192 11177 79
1750 720 AMA 500L10D 714 95.6 95.7 0.82 0.79 239 508 E 92 12869 68 196 13140 79
2000 3600 AMA 450L2D 3579 96.0 96.0 0.88 0.86 255 552 E 71 2936 51 235 8752 86
2000 1800 AMA 450L4D 1784 95.4 95.7 0.87 0.86 259 488 D 67 5889 65 189 8466 81
2000 1200 AMA 450L6D 1190 95.8 96.1 0.87 0.85 259 542 E 76 8828 69 204 9590 81
2000 900 AMA 500L8D 892 95.6 96.1 0.87 0.85 260 497 D 73 11784 67 193 12170 79
2250 3600 AMA 450L2D 3578 96.1 96.3 0.89 0.88 283 526 E 68 3303 49 221 9127 86
2250 1800 AMA 450L4D 1785 95.6 95.9 0.87 0.86 291 498 D 75 6626 68 192 8752 81
2250 1200 AMA 500L6D 1191 95.8 96.1 0.87 0.85 291 536 E 85 9926 70 205 10913 81
2250 900 AMA 500L8D 892 95.8 96.2 0.86 0.85 293 506 E 86 13247 67 191 12831 79
2500 3600 AMA 450L2D 3579 96.6 96.7 0.90 0.89 311 553 E 71 3670 54 229 9811 86
2500 1800 AMA 450L4D 1786 96.1 96.3 0.89 0.88 315 520 E 74 7354 66 195 9326 81
2500 1200 AMA 500L6D 1192 96.3 96.6 0.89 0.87 316 547 E 82 11020 67 206 11640 81
2500 900 AMA 500L8D 892 96.0 96.4 0.87 0.86 322 502 D 87 14729 69 193 13404 79
3000 3600 AMA 500L2D 3580 96.5 96.5 0.90 0.89 371 566 E 84 4403 54 238 12081 87
3000 1800 AMA 500L4D 1790 96.3 96.4 0.87 0.85 386 553 E 112 8804 65 207 11244 83
3000 1200 AMA 500L6D 1192 96.4 96.7 0.89 0.89 375 539 E 87 13226 67 200 12632 81
3500 3600 AMA 500L2D 3579 96.6 96.7 0.91 0.90 430 553 E 88 5138 54 228 12853 87
3500 1800 AMA 500L4D 1790 96.5 96.6 0.88 0.87 445 554 E 117 10271 66 203 11971 83
3500 1200 AMA 500L6D 1193 96.6 96.8 0.89 0.88 439 560 E 111 15421 69 204 13558 81
4000 1800 AMA 500L4D 1790 96.6 96.8 0.88 0.87 505 557 E 127 11738 68 203 12632 83
4500 1800 AMA 500L4D 1790 96.7 96.9 0.89 0.88 562 559 E 131 13206 70 200 13316 83

IEC frame size NEMA frame size Data presented in rating lists are typical values.
Guaranteed values on request. All engineered motors
400 68xx are optimized for the specied application. Accurate
450 72xx motor data will be given on request at quotation phase.
Legally binding performance and specication data is
500 80xx
given to the end user once each order is conrmed.

312 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 HV Modular motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEAAC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
200 600 AMA 400L12A 593 91.6 91.0 0.71 0.64 33 418 E 18 1769 76 200 6415 77
250 600 AMA 400L12A 593 91.9 91.4 0.70 0.64 41 417 E 23 2208 77 193 6614 77
300 600 AMA 400L12A 593 92.2 91.7 0.70 0.64 50 417 E 28 2658 76 195 7033 77
350 720 AMA 400L10A 712 93.1 92.9 0.73 0.67 55 442 E 29 2581 68 196 6415 78
350 600 AMA 400L12A 593 92.4 91.9 0.70 0.64 58 422 E 32 3098 79 196 7253 77
400 720 AMA 400L10A 712 93.3 93.2 0.75 0.69 61 450 E 31 2948 71 195 6636 78
400 600 AMA 400L12A 593 92.6 92.2 0.72 0.65 65 428 E 35 3538 81 194 7672 77
450 900 AMA 400L8A 890 94.0 94.0 0.82 0.79 63 484 E 24 2659 75 198 6437 79
450 720 AMA 400L10A 712 93.5 93.4 0.75 0.70 69 450 E 34 3325 72 196 6834 78
450 600 AMA 450L12A 594 93.7 93.6 0.74 0.68 70 452 E 36 3984 75 204 8620 77
500 900 AMA 400L8A 891 94.2 94.2 0.82 0.78 70 486 E 28 2950 74 200 6636 79
500 720 AMA 400L10A 713 93.8 93.5 0.73 0.67 78 455 E 42 3685 67 199 7452 78
500 600 AMA 450L12A 594 93.7 93.7 0.75 0.70 76 463 E 38 4424 80 202 8841 77
600 900 AMA 400L8A 891 94.4 94.4 0.81 0.77 84 492 E 34 3542 76 200 6856 79
600 720 AMA 400L10A 713 93.9 93.8 0.74 0.68 93 445 E 48 4427 65 192 7871 78
600 600 AMA 450L12A 594 93.9 93.9 0.75 0.69 92 459 E 46 5312 78 199 9370 77
700 1200 AMA 400L6A 1189 94.4 94.3 0.81 0.76 99 519 F 42 3092 73 206 6460 81
700 900 AMA 400L8A 891 94.4 94.5 0.82 0.78 98 490 E 39 4127 75 198 7209 79
700 720 AMA 450L10A 713 94.3 94.4 0.80 0.76 99 472 E 42 5158 72 197 8841 78
700 600 AMA 450L12A 595 94.1 94.0 0.74 0.67 109 467 F 58 6184 77 207 10141 77
800 1200 AMA 400L6A 1189 94.6 94.5 0.80 0.75 114 521 F 50 3536 74 207 6658 81
800 900 AMA 400L8A 891 94.5 94.7 0.82 0.78 111 493 E 44 4721 78 196 7430 79
800 720 AMA 450L10A 713 94.4 94.6 0.81 0.77 113 480 E 47 5900 76 197 9105 78
800 600 AMA 500L12A 595 94.5 94.4 0.76 0.70 121 485 F 61 7069 74 206 11684 77
900 3600 AMA 400L2A 3576 94.6 94.4 0.88 0.85 117 589 F 34 1321 65 249 6482 88
900 1200 AMA 400L6A 1189 94.8 94.9 0.81 0.76 126 522 F 53 3974 74 203 6878 81
900 900 AMA 400L8A 890 94.7 94.8 0.84 0.80 122 509 E 45 5307 85 198 7848 79
900 720 AMA 450L10A 713 94.6 94.8 0.82 0.78 125 480 E 49 6632 77 195 9634 78
900 600 AMA 500L12A 595 94.7 94.6 0.77 0.72 133 476 E 63 7947 72 200 12346 77
1000 3600 AMA 400L2A 3578 95.0 94.8 0.89 0.87 127 605 F 34 1468 62 254 6768 88
1000 1800 AMA 400L4A 1786 94.8 94.8 0.88 0.86 129 532 E 37 2942 61 217 6658 81
1000 1200 AMA 400L6A 1190 95.0 94.9 0.80 0.76 141 535 F 62 4415 75 205 7253 81
1000
1000
1000
900
720
600
AMA 450L8A
AMA 500L10A
AMA 500L12A
892
715
595
95.1
95.2
94.8
95.3
95.1
94.8
0.85
0.80
0.79
0.82
0.76
0.74
133
141
144
526
524
487
E
F
E
45
62
64
5890
7349
8837
73
64
76
201
220
201
9171
11707
13338
79
78
77
7

Data presented in rating lists are typical values.


IEC frame size NEMA frame size Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
400 68xx
motor data will be given on request at quotation phase.
450 72xx Legally binding performance and specication data is
500 80xx given to the end user once each order is conrmed.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 313


Class I Div/Zone 2 HV Modular motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEAAC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
1250 3600 AMA 400L2A 3578 95.3 95.3 0.90 0.89 156 598 F 36 1835 64 245 7209 88
1250 1800 AMA 400L4A 1788 95.2 95.3 0.89 0.87 159 583 F 46 3672 69 232 7253 81
1250 1200 AMA 450L6A 1191 95.2 95.2 0.85 0.82 166 551 F 57 5515 63 209 8951 81
1250 900 AMA 450L8A 892 95.3 95.6 0.85 0.83 166 520 E 55 7357 72 197 9965 79
1250 720 AMA 500L10A 714 95.2 95.4 0.83 0.80 169 508 E 62 9193 68 198 12368 78
1500 3600 AMA 400L2A 3579 95.6 95.6 0.88 0.86 192 626 F 54 2202 72 254 7518 88
1500 1800 AMA 400L4A 1787 95.4 95.6 0.89 0.88 190 560 E 51 4411 68 219 7518 81
1500 1200 AMA 450L6A 1191 95.3 95.4 0.86 0.84 197 540 E 63 6619 65 205 9237 81
1500 900 AMA 500L8A 893 95.5 95.7 0.85 0.82 199 536 E 68 8828 69 205 11729 79
1500 720 AMA 500L10A 714 95.3 95.4 0.83 0.80 203 525 E 76 11032 70 205 13558 78
1750 3600 AMA 450L2A 3580 95.3 95.2 0.89 0.87 223 563 E 59 2567 52 240 9215 89
1750 1800 AMA 450L4A 1789 95.3 95.2 0.88 0.87 224 596 F 64 5137 67 230 9193 82
1750 1200 AMA 450L6A 1192 95.6 95.7 0.85 0.83 231 557 F 76 7719 65 207 10031 81
1750 900 AMA 500L8A 893 95.6 95.8 0.86 0.84 229 534 E 73 10294 68 201 12699 79
2000 3600 AMA 450L2A 3580 95.6 95.5 0.88 0.87 255 572 F 68 2935 53 242 9546 89
2000 1800 AMA 450L4A 1789 95.5 95.5 0.90 0.89 251 577 F 59 5875 66 217 9744 82
2000 1200 AMA 500L6A 1192 95.5 95.7 0.88 0.86 257 542 E 73 8818 68 204 11486 81
2000 900 AMA 500L8A 893 95.7 95.9 0.85 0.83 263 535 E 86 11766 67 201 13382 79
2250 3600 AMA 450L2A 3581 95.8 95.7 0.89 0.87 285 572 F 71 3300 53 237 10229 89
2250 1800 AMA 500L4A 1792 95.6 95.5 0.89 0.87 286 614 F 81 6595 66 222 12170 84
2250 1200 AMA 500L6A 1192 95.7 95.9 0.88 0.86 288 549 E 80 9920 69 204 12147 81
2250 900 AMA 500L8A 893 95.9 96.1 0.85 0.83 295 544 E 97 13232 70 200 14043 79
2500 3600 AMA 500L2A 3582 96.0 95.9 0.90 0.89 311 589 F 73 3668 55 245 12610 90
2500 1800 AMA 500L4A 1791 96.0 95.9 0.90 0.88 313 592 F 79 7333 67 212 12147 84
2500 1200 AMA 500L6A 1193 96.2 96.3 0.88 0.87 317 555 E 86 11015 67 197 13140 81
3000 3600 AMA 500L2A 3582 96.3 96.2 0.90 0.89 373 602 F 88 4400 57 247 13338 90
3000 1800 AMA 500L4A 1791 96.1 96.2 0.90 0.90 372 557 E 80 8803 65 203 12787 84
3000 1200 AMA 500L6A 1193 96.4 96.5 0.89 0.88 375 569 E 91 13215 68 208 14132 81
3500 1800 AMA 500L4A 1791 96.4 96.5 0.90 0.90 433 580 E 96 10268 70 211 13536 84

Data presented in rating lists are typical values.


IEC frame size NEMA frame size
Guaranteed values on request. All engineered motors
400 68xx are optimized for the specied application. Accurate
motor data will be given on request at quotation phase.
450 72xx Legally binding performance and specication data is
500 80xx given to the end user once each order is conrmed.

314 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 HV Modular motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEWAC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
250 600 AMA 400L12L 593 91.9 91.6 0.71 0.65 41 403 E 22 2211 75 184 6041 77
300 600 AMA 400L12L 593 92.1 91.7 0.69 0.62 51 406 E 29 2660 76 190 6261 77
350 600 AMA 400L12L 593 92.3 92.0 0.70 0.64 58 398 E 32 3101 74 182 6482 77
400 720 AMA 400L10L 711 93.3 93.4 0.76 0.71 61 417 D 29 2952 65 179 6063 77
400 600 AMA 400L12L 592 92.6 92.4 0.73 0.67 64 397 D 32 3543 75 177 6878 77
450 720 AMA 400L10L 711 93.4 93.6 0.77 0.72 68 419 D 31 3330 67 179 6261 77
450 600 AMA 400L12L 593 92.7 92.5 0.71 0.65 73 406 E 39 3992 77 180 7099 77
500 900 AMA 400L8L 889 94.1 94.4 0.83 0.81 68 462 D 24 2955 74 184 6063 77
500 720 AMA 400L10L 711 93.6 93.8 0.77 0.72 75 423 D 34 3696 68 175 6482 77
500 600 AMA 400L12L 593 92.8 92.5 0.71 0.64 82 411 E 45 4429 77 185 7518 77
600 900 AMA 400L8L 889 94.3 94.6 0.84 0.81 82 450 D 28 3551 73 178 6283 77
600 720 AMA 400L10L 711 93.9 94.0 0.77 0.72 90 436 E 41 4435 69 180 7099 77
600 600 AMA 450L12L 593 94.0 94.2 0.77 0.72 90 431 D 42 5319 73 184 8686 78
700 900 AMA 400L8L 889 94.5 94.8 0.83 0.80 96 469 D 34 4135 78 184 6482 77
700 720 AMA 400L10L 711 94.0 94.2 0.77 0.72 104 436 E 47 5168 70 177 7518 77
700 600 AMA 450L12L 594 94.1 94.1 0.75 0.69 107 441 E 54 6191 73 191 9171 78
800 1200 AMA 400L6L 1187 94.7 95.0 0.83 0.80 109 500 E 41 3542 73 201 6085 79
800 900 AMA 400L8L 890 94.5 94.8 0.83 0.80 109 475 D 39 4727 78 185 6856 77
800 720 AMA 450L10L 712 94.4 94.7 0.82 0.79 111 449 D 42 5908 73 181 8400 78
800 600 AMA 450L12L 594 94.2 94.3 0.76 0.71 120 440 E 58 7083 74 187 9700 78
900 1200 AMA 400L6L 1188 94.9 95.1 0.82 0.79 124 511 E 48 3979 76 204 6305 79
900 900 AMA 400L8L 889 94.6 94.9 0.83 0.81 123 477 E 44 5313 80 184 7055 77
900 720 AMA 450L10L 712 94.5 94.8 0.82 0.79 125 454 D 47 6640 75 181 8664 78
900 600 AMA 500L12L 594 94.6 94.7 0.78 0.73 132 461 E 61 7955 72 190 11133 79
1000 3600 AMA 400L2L 3579 95.5 95.6 0.89 0.87 127 598 F 34 1468 60 249 6437 85
1000 1800 AMA 400L4L 1785 95.1 95.3 0.88 0.86 129 529 E 37 2943 65 213 6283 80
1000 1200 AMA 400L6L 1188 95.1 95.3 0.83 0.80 136 518 E 51 4423 78 204 6526 79
1000 900 AMA 400L8L 889 94.7 95.1 0.84 0.82 135 473 D 45 5909 80 181 7474 77
1000 720 AMA 450L10L 712 94.6 95.0 0.83 0.80 137 458 D 49 7383 77 181 9193 78
1000 600 AMA 500L12L 594 94.7 94.9 0.79 0.74 144 456 E 63 8845 71 187 11795 79
1250 3600 AMA 400L2L 3579 95.7 95.8 0.88 0.86 160 603 F 46 1834 62 249 6614 85
1250 1800 AMA 400L4L 1785 95.3 95.6 0.88 0.86 161 519 E 45 3678 67 206 6504 80
1250
1250
1250
1200
900
720
AMA 400L6L
AMA 450L8L
AMA 500L10L
1189
892
714
95.3
95.3
95.3
95.5
95.6
95.5
0.82
0.84
0.81
0.79
0.81
0.77
172
168
173
533
507
514
F
E
E
67
60
71
5527
7361
9189
80
72
68
204
193
203
7099
8708
11486
79
78
79
7
1250 600 AMA 500L12L 595 95.0 95.0 0.78 0.73 182 475 E 84 11042 74 195 13118 79

Data presented in rating lists are typical values.


IEC frame size NEMA frame size Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
400 68xx
motor data will be given on request at quotation phase.
450 72xx Legally binding performance and specication data is
500 80xx given to the end user once each order is conrmed.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 315


Class I Div/Zone 2 HV Modular motors 4000 V - 60 Hz
Technical data for totally enclosed squirrel
cage three phase motors
TEWAC Insulation class F, temperature rise class B, S.F. 1.0
Efciency Power factor Current Torque Sound
Full 3/4 Full 3/4 FLA LRA NLC Rated LRT BDT Motor pressure
Output Motor Speed load load load load weight level L
HP r/min type r/min 100% 75% 100% 75% A % Code A lb-ft % % lbs dB(A)

4000 V 60 Hz
1500 3600 AMA 400L2L 3579 95.9 96.1 0.89 0.87 189 599 F 50 2202 60 248 6900 85
1500 1800 AMA 400L4L 1784 95.3 95.7 0.87 0.85 195 513 E 57 4417 67 204 6680 80
1500 1200 AMA 450L6L 1191 95.6 95.8 0.86 0.83 197 541 E 63 6618 65 205 8774 81
1500 900 AMA 450L8L 893 95.6 95.8 0.83 0.79 205 521 E 79 8830 72 195 9502 78
1500 720 AMA 500L10L 714 95.4 95.6 0.82 0.78 207 503 E 82 11036 67 196 12147 79
1750 3600 AMA 400L2L 3579 96.0 96.3 0.89 0.88 219 599 F 54 2568 65 243 7385 85
1750 1800 AMA 400L4L 1785 95.6 96.0 0.89 0.88 222 519 E 56 5149 65 203 7121 80
1750 1200 AMA 450L6L 1191 95.7 96.0 0.86 0.83 230 533 E 73 7726 65 202 9061 81
1750 900 AMA 500L8L 891 95.6 96.0 0.86 0.84 229 490 D 68 10311 66 192 11177 79
1750 720 AMA 500L10L 714 95.6 95.7 0.82 0.79 239 508 E 92 12869 68 196 13140 79
2000 3600 AMA 450L2L 3579 96.0 96.0 0.88 0.86 255 552 E 71 2936 51 235 8752 86
2000 1800 AMA 450L4L 1784 95.4 95.7 0.87 0.86 259 488 D 67 5889 65 189 8466 81
2000 1200 AMA 450L6L 1190 95.8 96.1 0.87 0.85 259 542 E 76 8828 69 204 9590 81
2000 900 AMA 500L8L 892 95.6 96.1 0.87 0.85 260 497 D 73 11784 67 193 12170 79
2250 3600 AMA 450L2L 3578 96.1 96.3 0.89 0.88 283 526 E 68 3303 49 221 9127 86
2250 1800 AMA 450L4L 1785 95.6 95.9 0.87 0.86 291 498 D 75 6626 68 192 8752 81
2250 1200 AMA 500L6L 1191 95.8 96.1 0.87 0.85 291 536 E 85 9926 70 205 10913 81
2250 900 AMA 500L8L 892 95.8 96.2 0.86 0.85 293 506 E 86 13247 67 191 12831 79
2500 3600 AMA 450L2L 3579 96.6 96.7 0.90 0.89 311 553 E 71 3670 54 229 9811 86
2500 1800 AMA 450L4L 1786 96.1 96.3 0.89 0.88 315 520 E 74 7354 66 195 9326 81
2500 1200 AMA 500L6L 1192 96.3 96.6 0.89 0.87 316 547 E 82 11020 67 206 11640 81
2500 900 AMA 500L8L 892 96.0 96.4 0.87 0.86 322 502 D 87 14729 69 193 13404 79
3000 3600 AMA 500L2L 3580 96.5 96.5 0.90 0.89 371 566 E 84 4403 54 238 12081 87
3000 1800 AMA 500L4L 1790 96.3 96.4 0.87 0.85 386 553 E 112 8804 65 207 11244 83
3000 1200 AMA 500L6L 1192 96.4 96.7 0.89 0.89 375 539 E 87 13226 67 200 12632 81
3500 3600 AMA 500L2L 3579 96.6 96.7 0.91 0.90 430 553 E 88 5138 54 228 12853 87
3500 1800 AMA 500L4L 1790 96.5 96.6 0.88 0.87 445 554 E 117 10271 66 203 11971 83
3500 1200 AMA 500L6L 1193 96.6 96.8 0.89 0.88 439 560 E 111 15421 69 204 13558 81
4000 1800 AMA 500L4L 1790 96.6 96.8 0.88 0.87 505 557 E 127 11738 68 203 12632 83
4500 1800 AMA 500L4L 1790 96.7 96.9 0.89 0.88 562 559 E 131 13206 70 200 13316 83

Data presented in rating lists are typical values.


IEC frame size NEMA frame size Guaranteed values on request. All engineered motors
are optimized for the specied application. Accurate
400 68xx
motor data will be given on request at quotation phase.
450 72xx Legally binding performance and specication data is
500 80xx given to the end user once each order is conrmed.

316 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 - Engineered motors, HXR
Dimension drawings
Antifriction bearings, 1000 < U 6900 V, TEFC, F1

HXR Poles 2E 2F BA U N-W F D FP O C H FDS BS


IEC NEMA

355L 58xx 2 25.00 25.00 10.00 2.750 5.500 0.625 14.50 54.9 57.1 59.5 1.38 27.6 0.7
355L 58xx 4 25.00 25.00 10.00 4.000 8.250 1.000 14.50 54.9 57.1 65.7 1.38 27.6 0.7
400L 68xx 2 28.00 36.00 9.00 3.125 6.500 0.750 17.00 54.9 61.3 69.1 1.38 35.2 1.3
400L 68xx 4 28.00 36.00 9.00 4.375 8.250 1.000 17.00 54.9 61.3 74.6 1.38 35.2 1.3
450L 72xx 2 32.00 40.00 10.00 3.125 6.500 0.750 18.00 61.8 64.3 78.0 1.65 42.3 0.8
450L 72xx 4 32.00 40.00 10.00 4.375 8.250 1.000 18.00 61.8 64.3 83.5 1.65 42.3 0.8
500L 80xx 2 36.00 50.00 11.00 3.500 6.500 0.875 20.00 61.8 69.3 91.1 1.65 52.8 0.4
500L 80xx 4 36.00 50.00 11.00 4.750 8.250 1.250 20.00 61.8 69.3 96.7 1.65 52.8 0.4
560L 88xx 4 40.00 63.00 16.00 6.250 12.00 1.500 22.00 61.8 74.6 119.3 1.89 67.7 3.0

HXR Poles J A P K B G D-end bearing N-end bearing


IEC

355L
NEMA

58xx 2 4.9 28.0 29.5 8.3 34.9 2.7 6317M/C3 6317M/C3


7
355L 58xx 4 4.9 28.0 29.5 8.3 34.9 2.7 6322/C3 6319/C3
400L 68xx 2 5.5 33.1 33.1 10.0 44.1 2.6 6317M/C3 6317M/C3
400L 68xx 4 5.5 33.1 33.1 10.0 44.1 2.6 6324/C3 6319/C3
450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.86 6317M/C3 6317M/C3
450L 72xx 4 6.3 37.4 37.0 12.6 51.2 1.86 6324/C3 6322/C3
500L 80xx 2 6.7 41.2 41.5 14.8 61.8 2.1 6319M/C3 6319M/C3
500L 80xx 4 6.7 41.2 41.5 14.8 61.8 2.1 6326/C3 6324/C3
560L 88xx 4 9.1 46.1 46.9 24.4 76.4 1.9 6034/C3 + NU1034/C3 NU322/C3

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 317


Class I Div/Zone 2 - Engineered motors, HXR
Dimension drawings
Sleeve bearings, 1000 < U 6900 V, TEFC, F1

HXR Poles 2E 2F BA U N-W F D FP O C H FDS BS


IEC NEMA

355L 58xx 2 25.00 25.00 19.00 2.750 5.500 0.625 14.50 54.9 57.1 75.4 1.38 27.6 0.67
355L 58xx 4 25.00 25.00 19.00 4.000 8.250 1.000 14.50 54.9 57.1 81.9 1.38 27.6 0.67
400L 68xx 2 28.00 36.00 18.00 3.125 6.500 0.750 17.00 54.9 61.3 85.2 1.38 35.3 1.3
400L 68xx 4 28.00 36.00 18.00 4.375 8.250 1.000 17.00 54.9 61.3 90.7 1.38 35.3 1.3
450L 72xx 2 32.00 40.00 19.00 3.125 6.500 0.750 18.00 61.8 64.3 94.1 1.65 42.3 0.8
450L 72xx 4 32.00 40.00 19.00 4.375 8.250 1.000 18.00 61.8 64.3 99.6 1.65 42.3 0.8
500L 80xx 2 36.00 50.00 20.00 3.500 6.500 0.875 20.00 61.8 69.3 106.7 1.65 52.8 0.4
500L 80xx 4 36.00 50.00 20.00 4.750 8.250 1.250 20.00 61.8 69.3 112.2 1.65 52.8 0.4
560L 88xx 4 40.00 63.00 26.50 6.250 12.00 1.500 22.00 61.8 74.6 136.4 1.89 67.7 2.8

HXR Poles J A P K B G D-end bearing N-end bearing


IEC NEMA

355L 58xx 2 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-80 EFZLQ 9-80
355L 58xx 4 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-90 EFZLQ 9-90

7 400L
400L
68xx
68xx
2
4
5.5
5.5
33.1
33.1
33.1
33.1
10.0
10.0
44.1
44.1
2.6
2.6
EFZLB 9-80
EFZLB 9-100
EFZLQ 9-80
EFZLQ 9-100
450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-80 EFZLQ 9-80
450L 72xx 4 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-100 EFZLQ 9-100
500L 80xx 2 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 9-90 EFZLQ 9-90
500L 80xx 4 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 11-100 EFZLQ 9-100
560L 88xx 4, 6 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-125 EFZLQ 14-125
560L 88xx 4 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-140 EFZLQ 14-140

Note! Includes provision for BN proximity probes.


Note! Axial oat of rotor as standard 0.31 inch. Above table gives the main dimensions in inches.
Note! The bearing can not withstand continuous axial forces. The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

318 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 - Engineered motors, HXR
Dimension drawings
Antifriction bearings, 1000 < U 6900 V, TEFC, F2

HXR Poles 2E 2F BA U N-W F D FP O C H FDS BS


IEC NEMA

355L 58xx 2 25.00 25.00 10.00 2.750 5.500 0.625 14.50 54.9 57.1 59.3 1.38 27.6 0.7
355L 58xx 4 25.00 25.00 10.00 4.000 8.250 1.000 14.50 54.9 57.1 65.7 1.38 27.6 0.7
400L 68xx 2 28.00 36.00 9.00 3.125 6.500 0.750 17.00 54.9 61.3 69.1 1.38 35.2 1.3
400L 68xx 4 28.00 36.00 9.00 4.375 8.250 1.000 17.00 54.9 61.3 74.6 1.38 35.2 1.3
450L 72xx 2 32.00 40.00 10.00 3.125 6.500 0.750 18.00 61.8 64.3 78.0 1.65 42.3 0.8
450L 72xx 4 32.00 40.00 10.00 4.375 8.250 1.000 18.00 61.8 64.3 83.5 1.65 42.3 0.8
500L 80xx 2 36.00 50.00 11.00 3.500 6.500 0.875 20.00 61.8 69.3 91.1 1.65 52.8 0.4
500L 80xx 4 36.00 50.00 11.00 4.750 8.250 1.250 20.00 61.8 69.3 96.7 1.65 52.8 0.4
560L 88xx 4 40.00 63.00 16.00 6.250 12.00 1.500 22.00 61.8 74.6 119.3 1.89 67.7 3.0

HXR Poles J A P K B G D-end bearing N-end bearing


IEC NEMA

355L 58xx 2 4.9 28.0 29.5 8.3 34.9 2.7 6317M/C3 6317M/C3
355L 58xx 4 4.9 28.0 29.5 8.3 34.9 2.7 6322/C3 6319/C3
400L
400L
68xx
68xx
2
4
5.5
5.5
33.1
33.1
33.1
33.1
10.0
10.0
44.1
44.1
2.6
2.6
6317M/C3
6324/C3
6317M/C3
6319/C3
7
450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.85 6317M/C3 6317M/C3
450L 72xx 4 6.3 37.4 37.0 12.6 51.2 1.85 6324/C3 6322/C3
500L 80xx 2 6.7 41.2 41.5 14.8 61.8 2.1 6319M/C3 6319M/C3
500L 80xx 4 6.7 41.2 41.5 14.8 61.8 2.1 6326/C3 6324/C3
560L 88xx 4 9.1 46.1 46.9 24.5 76.4 1.9 6034/C3 + NU1034/C3 NU322/C3

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 319


Class I Div/Zone 2 - Engineered motors, HXR
Dimension drawings
Sleeve bearings, 1000 < U 6900 V, TEFC, F2

HXR Poles 2E 2F BA U N-W F D FP O C H FDS BS


IEC NEMA

355L 58xx 2 25.00 25.00 19.00 2.750 5.500 0.625 14.50 54.9 57.1 75.4 1.38 27.6 0.67
355L 58xx 4 25.00 25.00 19.00 4.000 8.250 1.000 14.50 54.9 57.1 81.9 1.38 27.6 0.67
400L 68xx 2 28.00 36.00 18.00 3.125 6.500 0.750 17.00 54.9 61.3 85.2 1.38 35.3 1.3
400L 68xx 4 28.00 36.00 18.00 4.375 8.250 1.000 17.00 54.9 61.3 90.7 1.38 35.3 1.3
450L 72xx 2 32.00 40.00 19.00 3.125 6.500 0.750 18.00 61.8 64.3 94.1 1.65 42.3 0.8
450L 72xx 4 32.00 40.00 19.00 4.375 8.250 1.000 18.00 61.8 64.3 99.6 1.65 42.3 0.8
500L 80xx 2 36.00 50.00 20.00 3.500 6.500 0.875 20.00 61.8 69.3 106.7 1.65 52.8 0.4
500L 80xx 4 36.00 50.00 20.00 4.750 8.250 1.250 20.00 61.8 69.3 112.2 1.65 52.8 0.4
560L 88xx 4 40.00 63.00 26.50 6.250 12.00 1.500 22.00 61.8 74.6 136.4 1.89 67.7 2.8

HXR Poles J A P K B G D-end bearing N-end bearing


IEC NEMA

355L 58xx 2 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-80 EFZLQ 9-80
355L 58xx 4 4.9 28.0 29.4 8.3 34.9 2.7 EFZLB 9-90 EFZLQ 9-90

7 400L
400L
68xx
68xx
2
4
5.5
5.5
33.1
33.1
33.1
33.1
10.0
10.0
44.1
44.1
2.6
2.6
EFZLB 9-80
EFZLB 9-100
EFZLQ 9-80
EFZLQ 9-100
450L 72xx 2 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-80 EFZLQ 9-80
450L 72xx 4 6.3 37.4 37.0 12.6 51.2 1.9 EFZLB 9-100 EFZLQ 9-100
500L 80xx 2 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 9-90 EFZLQ 9-90
500L 80xx 4 6.7 41.3 41.2 14.8 61.8 2.1 EFZLB 11-100 EFZLQ 9-100
560L 88xx 4, 6 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-125 EFZLQ 14-125
560L 88xx 4 9.1 46.1 46.9 24.4 76.4 1.9 EFZLB 14-140 EFZLQ 14-140

Note! Includes provision for BN proximity probes.


Note! Axial oat of rotor as standard 0.31 inch. Above table gives the main dimensions in inches.
Note! The bearing can not withstand continuous axial forces.
The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

320 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 - Engineered motors, HXR
Dimension drawings
Antifriction bearings, 1000 < U 6900 V, TEFC, F1, ange mounting

HXR Poles 2E 2F A AB AC AE AF AJ AK B BA BB BD
IEC NEMA

355L 58xx 2 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50
355L 58xx 4 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50
400L 68xx 2 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37
400L 68xx 4 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37
450L 72xx 2 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28
450L 72xx 4 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28
500L 80xx 2 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28
500L 80xx 4 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28
560L 88xx 4 40.00 63.00 46.1 40.7 32.4 53.5 18.4 51.97 49.21 76.4 16.00 0.236 55.12

HXR Poles BE BF BS C D EV F FDS G H J K


IEC NEMA

355L 58xx 2 0.984 0.945 27.0 59.3 14.50 4.2 0.625 0.55 2.68 1.38 4.9 8.3
355L 58xx 4 0.984 0.945 27.0 65.7 14.50 4.2 1.000 0.55 2.68 1.38 4.9 8.3
400L 68xx 2 1.181 1.102 36.2 69.1 17.00 3.4 0.750 0.95 2.64 1.38 5.5 10.0
400L 68xx 4 1.181 1.102 36.2 74.6 17.00 3.4 1.000 0.95 2.64 1.38 5.5 10.0
450L 72xx 2 1.181 1.102 43.0 78.0 18.00 3.7 0.750 0.63 1.85 1.65 6.3 12.6
450L 72xx 4 1.181 1.102 43.0 83.5 18.00 3.7 1.000 0.63 1.85 1.65 6.3 12.6
500L 80xx 2 1.181 1.102 53.6 91.1 20.00 3.9 0.875 0.83 2.09 1.65 6.7 14.8
500L 80xx 4 1.181 1.102 53.6 96.7 20.00 3.9 1.250 0.83 2.09 1.65 6.7 14.8
560L 88xx 4 2.362 1.102 65.5 119.3 22.00 6.9 1.500 2.21 1.93 1.89 9.1 24.4

HXR
IEC NEMA
Poles N-W O P U D-end bearing N-end bearing 7
355L 58xx 2 5.500 57.1 29.5 2.750 6317/C3 6317/C3
355L 58xx 4 8.250 57.1 29.5 4.000 6322/C3 6319/C3
400L 68xx 2 6.500 61.3 33.1 3.125 6317/C3 6317/C3
400L 68xx 4 8.250 61.3 33.1 4.375 6324/C3 6319/C3
450L 72xx 2 6.500 64.3 37.0 3.125 6317/C3 6317/C3
450L 72xx 4 8.250 64.3 37.0 4.375 6324/C3 6322/C3
500L 80xx 2 6.500 69.3 40.9 3.500 6319M/C3 6319M/C3
500L 80xx 4 8.250 69.3 40.9 4.750 6326/C3 6324/C3
560L 88xx 4 12.00 74.6 46.9 6.250 6034/C3 + NU1034/C3 NU322/C3

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
Direction of rotation according to order.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 321


Class I Div/Zone 2 - Engineered motors, HXR
Dimension drawings
Antifriction bearings, 1000 < U 6900 V, TEFC, F2, ange mounting

HXR Poles 2E 2F A AB AC AE AF AJ AK B BA BB BD
IEC NEMA

355L 58xx 2 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50
355L 58xx 4 25.00 25.00 28.0 37.3 28.9 35.9 18.4 29.13 26.77 34.9 10.00 0.236 31.50
400L 68xx 2 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37
400L 68xx 4 28.00 36.00 33.1 37.3 28.9 40.2 18.4 37.00 34.65 44.1 9.00 0.236 39.37
450L 72xx 2 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28
450L 72xx 4 32.00 40.00 37.4 40.7 32.4 43.2 18.4 42.52 39.37 51.2 10.00 0.236 45.28
500L 80xx 2 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28
500L 80xx 4 36.00 50.00 41.3 40.7 32.4 48.1 18.4 42.52 39.37 61.8 11.00 0.236 45.28
560L 88xx 4 40.00 63.00 46.1 40.7 32.4 53.5 18.4 51.97 49.21 76.4 16.00 0.236 55.12

HXR Poles BE BF BS C D EV F FDS G H J K


IEC NEMA

355L 58xx 2 0.984 0.945 27.0 59.3 14.50 4.2 0.625 0.55 2.68 1.38 4.9 8.3
355L 58xx 4 0.984 0.945 27.0 65.7 14.50 4.2 1.000 0.55 2.68 1.38 4.9 8.3
400L 68xx 2 1.181 1.102 36.2 69.1 17.00 3.4 0.750 0.95 2.64 1.38 5.5 10.0
400L 68xx 4 1.181 1.102 36.2 74.6 17.00 3.4 1.000 0.95 2.64 1.38 5.5 10.0
450L 72xx 2 1.181 1.102 43.0 78.0 18.00 3.7 0.750 0.63 1.85 1.65 6.3 12.6
450L 72xx 4 1.181 1.102 43.0 83.5 18.00 3.7 1.000 0.63 1.85 1.65 6.3 12.6
500L 80xx 2 1.181 1.102 53.6 91.1 20.00 3.9 0.875 0.83 2.09 1.65 6.7 14.8
500L 80xx 4 1.181 1.102 53.6 96.7 20.00 3.9 1.250 0.83 2.09 1.65 6.7 14.8
560L 88xx 4 2.362 1.102 65.5 119.3 22.00 6.9 1.500 2.21 1.93 1.89 9.1 24.4

7 HXR
IEC NEMA
Poles N-W O P U D-end bearing N-end bearing

355L 58xx 2 5.500 57.1 29.5 2.750 6317/C3 6317/C3


355L 58xx 4 8.250 57.1 29.5 4.000 6322/C3 6319/C3
400L 68xx 2 6.500 61.3 33.1 3.125 6317/C3 6317/C3
400L 68xx 4 8.250 61.3 33.1 4.375 6324/C3 6319/C3
450L 72xx 2 6.500 64.3 37.0 3.125 6317/C3 6317/C3
450L 72xx 4 8.250 64.3 37.0 4.375 6324/C3 6322/C3
500L 80xx 2 6.500 69.3 40.9 3.500 6319M/C3 6319M/C3
500L 80xx 4 8.250 69.3 40.9 4.750 6326/C3 6324/C3
560L 88xx 4 12.00 74.6 46.9 6.250 6034/C3 + NU1034/C3 NU322/C3

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the foundation.
Certied outline drawing is delivered with each purchase order.
Direction of rotation according to order.

322 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 - Engineered motors, HXR
Dimension drawings
Antifriction bearings, 1000 < U 6900 V, TEFC, vertical

HXR Poles AB AC AF AJ AK BB BD BE BF BV C F
IEC NEMA

355L 58xx 4 41.00 32.70 18.40 29.13 26.77 0.236 31.50 0.984 0.945 37.00 65.70 1.000
400L 68xx 4 42.70 34.45 18.40 37.00 34.65 0.236 39.37 1.181 1.102 45.20 74.60 1.000
450L 72xx 4 44.70 36.40 18.40 42.52 39.37 0.236 45.28 1.181 1.102 52.95 83.50 1.000
500L 80xx 4 47.60 39.40 18.40 42.52 39.37 0.236 45.28 1.181 1.102 64.60 96.70 1.250
560L 88xx 6 51.00 42.70 18.40 51.97 49.21 0.236 55.12 1.575 1.102 80.70 118.5 1.500

HXR Poles FDS N-W P U D-end bearing N-end bearing


IEC NEMA

355L 58xx 4 10.0 8.250 29.5 4.000 6322/C3 7319 BM


400L 68xx 4 10.0 8.250 33.1 4.375 6324/C3 7319 BM
4
7
450L 72xx 10.6 8.250 37.0 4.375 6324/C3 7322 BM
500L 80xx 4 11.8 8.250 40.9 4.750 6326/C3 7324 BM
560L 88xx 6 13.0 12.00 46.9 6.250 6034/C3 7334 BM

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.
Rain canopy is recommended for outdoor location.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 323


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Antifriction bearings, 2300 < U 6900 V, F1/F2, WPII

AMA Poles 2E 2F BA N-W H G U F R SR D C O FP


IEC NEMA

400L 68xx 2 29.53 49.21 7.87 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 73.62 67.3 63.8
400L 68xx 4 29.53 49.21 7.87 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 75.20 67.3 63.8
450L 72xx 2 33.47 55.12 7.87 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 79.53 73.2 67.7
450L 72xx 4 33.47 55.12 7.87 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 81.10 73.2 67.7
500L 80xx 4 37.40 62.99 7.87 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 90.55 81.1 71.7

AMA Poles A B K FK J AB AC AE AF FDS BS


IEC NEMA

400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
400L 68xx 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
450L 72xx 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5

7 AMA
IEC NEMA
Poles D-end bearing N-end bearing

400L 68xx 2 6319M/C3 6319M/C3


400L 68xx 4 6324/C3 6319/C3
450L 72xx 2 6319M/C3 6319M/C3
450L 72xx 4 6326/C3 6322/C3
500L 80xx 4 6330/C3 6324/C3

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

324 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Sleeve bearings, 2300 < U 6900 V, F1/F2, WPII

AMA Poles 2E 2F BA N-W H G U F R SR D C O FP


IEC NEMA

400L 68xx 2 29.53 49.21 14.76 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 81.30 67.3 63.8
400L 68xx 4 29.53 49.21 14.76 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 82.68 67.3 63.8
450L 72xx 2 33.47 55.12 14.76 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 87.21 73.2 67.7
450L 72xx 4 33.47 55.12 15.75 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 89.57 73.2 67.7
500L 80xx 2 37.40 62.99 14.76 8.268 1.65 1.38 4.331 1.102 3.937 0.630 19.69 97.84 81.1 71.7
500L 80xx 4 37.40 62.99 17.72 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 102.17 81.1 71.7

AMA Poles A B K FK J AB AC AE AF FDS BS


IEC NEMA

400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
400L 68xx 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
450L 72xx 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
500L 80xx 2 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
500L

AMA
80xx 6

Poles
42.5 70.9 25.4

D-end bearing
19.5 5.9 46.3 37.8

N-end bearing
30.1 18.4 16.1 57.5
7
IEC NEMA

400L 68xx 2 EFZLB9-80 EFZLQ9-80


400L 68xx 4 EFZLB9-100 EFZLQ9-100
450L 72xx 2 EFZLB9-80 EFZLQ9-80
450L 72xx 4 EFZLB11-125 EFZLQ9-100
500L 80xx 2 EFNLB11-90 EFNLB11-90
500L 80xx 4 EFZLB14-125 EFZLQ11-125
500L 80xx 6 EFZLB14-140 EFZLQ11-125
Note! Includes provision for BN proximity probes.
Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 325


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Antifriction bearings, 2300 < U 6900 V, F1/F2, TEAAC

AMA Poles 2E 2F BA N-W H G U F R SR D C O FP


IEC NEMA

400L 68xx 2 29.53 49.21 7.87 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 90.16 62.6 63.8
400L 68xx 4 29.53 49.21 7.87 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 91.73 62.6 63.8
450L 72xx 2 33.47 55.12 7.87 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 97.64 69.3 67.7
450L 72xx 4 33.47 55.12 7.87 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 99.21 69.3 67.7
500L 80xx 4 37.40 62.99 7.87 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 111.42 77.2 71.7

AMA Poles A B K FK J AB AC AE AF FDS BS


IEC NEMA

400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
400L 68xx 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
450L 72xx 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5

7 AMA
IEC NEMA
Poles D-end bearing N-end bearing

400L 68xx 2 6319M/C3 6319M/C3


400L 68xx 4 6324/C3 6319/C3
450L 72xx 2 6319M/C3 6319M/C3
450L 72xx 4 6326/C3 6322/C3
500L 80xx 4 6330/C3 6324/C3

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

326 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Sleeve bearings, 2300 < U 6900 V, F1/F2, TEAAC

AMA Poles 2E 2F BA N-W H G U F R SR D C O FP


IEC NEMA

400L 68xx 2 29.53 49.21 14.76 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 97.05 62.6 63.8
400L 68xx 4 29.53 49.21 14.76 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 98.62 62.6 63.8
450L 72xx 2 33.47 55.12 14.76 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 104.53 69.3 67.7
450L 72xx 4 33.47 55.12 15.75 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 107.09 69.3 67.7
500L 80xx 2 37.40 62.99 14.76 8.268 1.65 1.38 4.331 1.102 3.937 0.630 19.69 116.73 77.2 71.7
500L 80xx 4 37.40 62.99 17.72 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 121.26 77.2 71.7

AMA Poles A B K FK J AB AC AE AF FDS BS


IEC NEMA

400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
400L 68xx 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
450L 72xx 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
500L 80xx 2 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
500L

AMA
80xx 6

Poles
42.5 70.9 25.4

D-end bearing
19.5 5.9 46.3 37.8

N-end bearing
30.1 18.4 16.1 57.5
7
IEC NEMA

400L 68xx 2 EFZLB9-80 EFZLQ9-80


400L 68xx 4 EFZLB9-100 EFZLQ9-100
450L 72xx 2 EFZLB9-80 EFZLQ9-80
450L 72xx 4 EFZLB11-125 EFZLQ9-100
500L 80xx 2 EFNLB11-90 EFNLB11-90
500L 80xx 4 EFZLB14-125 EFZLQ11-125
500L 80xx 6 EFZLB14-140 EFZLQ11-125

Note! Includes provision for BN proximity probes.


Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 327


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Antifriction bearings, 2300 < U 6900 V, F1/F2, TEWAC

AMA Poles 2E 2F BA N-W H G U F R SR D C O FP


IEC NEMA

400L 68xx 2 29.53 49.21 7.87 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 73.62 65.7 63.8
400L 68xx 4 29.53 49.21 7.87 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 75.20 65.7 63.8
450L 72xx 2 33.47 55.12 7.87 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 79.53 73.6 67.7
450L 72xx 4 33.47 55.12 7.87 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 81.10 73.6 67.7
500L 80xx 4 37.40 62.99 7.87 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 90.55 81.5 71.7

AMA Poles A B K FK J AB AC AE AF FDS BS


IEC NEMA
400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
400L 68xx 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
450L 72xx 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5

7 AMA
IEC NEMA
Poles D-end bearing N-end bearing

400L 68xx 2 6319M/C3 6319M/C3


400L 68xx 4 6324/C3 6319/C3
450L 72xx 2 6319M/C3 6319M/C3
450L 72xx 4 6326/C3 6322/C3
500L 80xx 4 6330/C3 6324/C3

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

328 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Sleeve bearings, 2300 < U 6900 V, F1/F2, TEWAC

AMA Poles 2E 2F BA N-W H G U F R SR D C O FP


IEC NEMA
400L 68xx 2 29.53 49.21 14.76 6.693 1.38 0.79 3.346 0.866 2.992 0.551 15.75 81.30 65.7 63.8
400L 68xx 4 29.53 49.21 14.76 8.268 1.38 0.79 4.331 1.102 3.937 0.630 15.75 82.68 65.7 63.8
450L 72xx 2 33.47 55.12 14.76 6.693 1.65 0.98 3.543 0.984 3.189 0.551 17.72 87.21 73.6 67.7
450L 72xx 4 33.47 55.12 15.75 8.268 1.65 0.98 4.921 1.260 4.488 0.709 17.72 89.57 73.6 67.7
500L 80xx 2 37.40 62.99 14.76 8.268 1.65 1.38 4.331 1.102 3.937 0.630 19.69 97.84 81.5 71.7
500L 80xx 4 37.40 62.99 17.72 9.843 1.65 1.38 5.512 1.417 5.039 0.787 19.69 102.17 81.5 71.7

AMA Poles A B K FK J AB AC AE AF FDS BS


IEC NEMA
400L 68xx 2 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
400L 68xx 4 34.6 57.1 21.5 17.5 5.9 42.3 33.9 22.2 18.4 9.6 43.7
450L 72xx 2 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
450L 72xx 4 38.6 63.0 22.6 18.3 5.9 44.3 35.9 26.2 18.4 13.4 49.6
500L 80xx 2 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
500L 80xx 4 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5
500L 80xx 6 42.5 70.9 25.4 19.5 5.9 46.3 37.8 30.1 18.4 16.1 57.5

AMA Poles D-end bearing N-end bearing


7
IEC NEMA
400L 68xx 2 EFZLB9-80 EFZLQ9-80
400L 68xx 4 EFZLB9-100 EFZLQ9-100
450L 72xx 2 EFZLB9-80 EFZLQ9-80
450L 72xx 4 EFZLB11-125 EFZLQ9-100
500L 80xx 2 EFNLB11-90 EFNLB11-90
500L 80xx 4 EFZLB14-125 EFZLQ11-125
500L 80xx 6 EFZLB14-140 EFZLQ11-125

Note! Includes provision for BN proximity probes.


Above table gives the main dimensions in inches.
The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 329


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1000 < U 6900 V, WPII, vertical

AMA Poles AB AC AD AF AJ AK BB BD BE BF BV C
IEC NEMA

400L 68xx 4 42.2 34.1 1.97 18.4 42.52 39.37 0.236 44.49 1.181 1.102 49.0 75.4
450L 72xx 4 44.2 36.0 1.97 18.4 46.46 44.09 0.276 48.43 1.575 1.102 54.9 81.3
500L 80xx 4 46.2 38.0 1.97 18.4 51.97 49.21 0.315 53.94 1.850 1.102 62.8 90.7

AMA Poles FDS N-W P R S T U U-R D-end bearing N-end bearing


IEC NEMA

400L 68xx 4 17.5 8.268 73.8 3.937 1.102 3.15 4.331 0.630 6324/C3 7319B
450L 72xx 4 21.3 8.268 79.7 4.488 1.260 3.15 4.921 0.709 6326/C3 7322B
500L 80xx 4 24.0 9.843 88.4 5.039 1.417 3.15 5.512 0.787 6330/C3 7324B

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

330 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1000 < U 6900 V, TEAAC, vertical

AMA Poles AB AC AD AF AJ AK BB BD BE BF BV C
IEC NEMA

400L 68xx 4 42.2 34.1 1.97 18.4 42.52 39.37 0.236 44.49 1.181 1.102 49.0 91.7
450L 72xx 4 44.2 36.0 1.97 18.4 46.46 44.09 0.276 48.43 1.575 1.102 54.9 99.2
500L 80xx 4 46.2 38.0 1.97 18.4 51.97 49.21 0.315 53.94 1.850 1.102 62.8 111.4

AMA Poles FDS N-W P R S U U-R D-end bearing N-end bearing


IEC NEMA

400L 68xx 4 17.5 8.268 69.3 3.937 1.102 4.331 0.630 6324/C3 7319B
450L 72xx 4 21.3 8.268 76.0 4.488 1.260 4.921 0.709 6326/C3 7322B
500L 80xx 4 24.0 9.843 84.6 5.039 1.417 5.512 0.787 6330/C3 7324B

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 331


Class I Div/Zone 2 - Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1000 < U 6900 V, TEWAC, vertical

AMA Poles AB AC AD AF AJ AK BB BD BE BF BV C
IEC NEMA

400L 68xx 4 42.2 34.1 1.97 18.4 42.52 39.37 0.236 44.49 1.181 1.102 49.0 91.8
450L 72xx 4 44.2 36.0 1.97 18.4 46.46 44.09 0.276 48.43 1.575 1.102 54.9 81.3
500L 80xx 4 46.2 38.0 1.97 18.4 51.97 49.21 0.315 53.94 1.850 1.102 62.8 90.7

AMA Poles FDS N-W P R S T U U-R D-end bearing N-end bearing


IEC NEMA

400L 68xx 4 17.5 8.268 72.3 3.937 1.102 3.15 4.331 0.630 6324/C3 7319B
450L 72xx 4 21.3 8.268 80.0 4.488 1.260 3.15 4.921 0.709 6326/C3 7322B
500L 80xx 4 24.0 9.843 89.0 5.039 1.417 3.15 5.512 0.787 6330/C3 7324B

Above table gives the main dimensions in inches.


The customer is responsible for the preparation of the
foundation. Certied outline drawing is delivered with each
purchase order. Direction of rotation according to order.

332 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


NEMA type II terminal box (normal size)
The high voltage terminal box is shown below. The main
technical data are listed below.

Technical data: Materials:


Voltage (max.) 6.9 kV Box welded sheet steel
Current (max.) 600 A (thickness min. 0.12")
No of cables (max.) 2 per phase Cable gland plate steel
Cable gland blind gland (1 pce) Connection hooks Copper Cu
Connection hooks 0.3" x 2.36" (3 pcs) Isolators epoxy casting resin
Clearance (min.) 5.9 in Grounding pad stainless steel
Creepage (min.) 10 in
Usable volume 18 000 in3 Other features:
Ground connections M16 (both in- and - rigid welded construction
outside) - ample size for making connections of supply cables
Weight 230 lbs - box turnable to allow cable entry from left or right
Protection NEMA 4 side
Standard NEMA MG 1, Part 20 - box turnable in steps of 90
- either 3-phase or 1-phase cables can be connected
- all removable cover plates are bolted and gasketed
- different cable glands available.

Figure above: High voltage NEMA Type II terminal box (normal size). Dimensions in inches [mm].

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 333


NEMA type II terminal box (over size)
The high voltage terminal box is shown below. The main
technical data are listed below.

Technical data: Materials:


Voltage (max.) 6.9 kV Box welded sheet steel
Current (max.) 600 A (thickness min. 0.12")
No of cables (max.) 2 per phase Cable gland plate steel
Cable gland blind gland (1 pce) Connection hooks Copper Cu
Connection hooks 0.3" x 2.36" (3 pcs) Isolators epoxy casting resin
Clearance (min.) 5.9 in Grounding pad stainless steel
Creepage (min.) 10 in
Usable volume 36 000 in3 Other features:
Ground connections M16 (both in- and - rigid welded construction
outside) - ample size for making connections of supply cables
Weight 375 lbs - box turnable to allow cable entry from left or right
Protection NEMA 4 side
Standard NEMA MG 1, Part 20 - box turnable in steps of 90
- either 3-phase or 1-phase cables can be connected
- all removable cover plates are bolted and gasketed
- different cable glands available
- can be equipped with: current transformer (CT),
lightning arrester (LA), surge capasitor (SC)

Figure above: High voltage NEMA Type II terminal box (over size). Dimensions in inches [mm].

334 ABB/ BU Machines / COG catalogue / Class I EN 02-2008


7

ABB/ BU Machines / COG catalogue / Class I EN 02-2008 335


336 ABB/ BU Machines / Motors for COG EN 02-2008
ABB/ BU Machines / Motors for COG EN 02-2008 337
ABB Low voltage motor's product offer
for hazardous areas
Flameproof motors
Type of protection: Ex d/Ex de IIB/IIC T4
Features: All common voltages, 50/60 Hz, 2-8 poles, VSD applications, IP55, IC411
Motor type IEC frame sizes Output kW
Cast iron 80 - 400 0.55 - 710 kW

Increased safety motors


Type of protection: Ex e II T3
Features: All common voltages, 50/60 Hz, 2-8 poles
Motor type IEC frame size Output kW
Aluminum 90 - 250 1.1 - 55 kW
Cast iron 80 - 400 0.55 - 390 kW

Non-sparking motors
Type of protection: Ex nA
Features: All common voltages, 50/60 Hz, 2-8 poles, VSD applications
Motor type IEC frame size Output kW
Aluminum 90 - 280 1.1 - 72
Cast iron 71 - 450 0.25 - 1000 kW

Dust ignition proof motors


Type of protection: Ex tD (DIP) A21, 2D, T125, IP65 & Ex tD (DIP) A22, 3D, T125, IP55
Features: All common voltages, 50/60 Hz, 2-8 poles, VSD applications
Motor type IEC frame size Output kW
Aluminum 71 - 280 0.25 - 75 kW
Cast iron 160 - 400 11 - 710 kW

More information for these motors


can be found from web-pages:
www.abb.com/motors&generators

338 ABB/ BU Machines / Motors for COG EN 02-2008


ABB Motors total product offer
ABB offers several comprehensive ranges of AC motors
and generators. We manufacture synchronous motors for
even the most demanding applications, and a full range
of low and high voltage induction motors. Our in-depth
knowledge of virtually every type of industrial
processing ensures we always specify the best solution
for your needs.

M000328
Low voltage motors and generators

General purpose motor for Process performance motors for Motors for hazardous areas
standard applications more demanding applications Flameproof motors
Aluminum motors Aluminum motors Increased safety motors
Steel motors Cast iron motors (IEC and NEMA) Non-sparking motors
Cast iron motors Motors for high ambient Dust ignition proof motors
Open drip proof motors temperatures
Global motors Permanent magnet motors Marine motors
Brake motors High speed motors Aluminum motors
Single phase motors Wind turbine generators Steel motors
Servomotors Smoke venting motors Cast iron motors
Water cooled motors Open drip proof motors
Motors for roller table drives

High voltage and synchronous motors


and generators
High voltage cast iron motors
Induction modular motors
Slip ring motors
Motors for hazardous areas
Synchronous motors and generators
DC motors and generators

ABB/ BU Machines / Motors for COG EN 02-2008 339


Printed in Finland, 03-2008/3000, Waasa Graphics Oy
ABB (www.abb.com) is a leader in power and automation
technologies that enable utility and industry customers to improve
their performance while lowering environmental impact. The ABB
Group of companies operates in around 100 countries and employs
about 110,000 people.

ABB's web site provides further information, including a library


of documents. Visit www.abb.com/motors&generators.

www.abb.com/motors&generators
> Motors
>> Motors for hazardous areas
>>> Hazardous environment
>>> International standards
>>> Certicates
>>> Gas protection
>>> Dust ignition protection
>>> Product range

9AKK104340 EN 02-2008

Copyright 2008 ABB All rights reserved.


www.abb.com/motors&generators Specications subject to change without notice.

Das könnte Ihnen auch gefallen