Sie sind auf Seite 1von 2

SALES BULLETIN MEASUREMENT SOLUTIONS

Smith Meter PRIME 4 We put you first.


And keep you ahead.

FOR ACCURATE, RELIABLE, AFFORDABLE


MEASUREMENT OF LIQUIDS AT THE TERMINAL Long Radius
Accurate: FMC Technologies realizes that loading rack Flow Pattern

meters are important to liquid terminals, not only for


custody transfer, but also for liquid inventory control
and leak detection. Liquid measurement numbers that
terminal managers rely on are only as good as the
meters being used.

The Smith Meter PRIME 4 is the best meter to use because


it delivers superior accuracy, stability, and meets or exceeds
Single Case
all load rack requirements. This enhanced performance is Housing
Direct
made possible with unique features including: Pulse Output
Polyketone blades
Super-hardened cam
Horizontal rotor with long-life journal bearings
Direct pulse output which eliminates the mechanical Superhardened
Cam
calibrator
Polyketone
Reliable: Reliability of metering equipment is as equally Blades

important as accuracy at the liquid terminal. Due to Vent/Drain


(3 places) Horizontal Shaft
increased product throughput demands, minimal downtime and Journal Bearing
and maintenance are essential.
(continued on next page)
We put you first.
And keep you ahead.

The PRIME 4 was engineered and manufactured to ensure


TECHNICAL SPECIFICATIONS
trouble-free operation. The packing gland and most bearings
have been eliminated, and wear is reduced by using: Line Size 4" ANSI Class 150; DN 100, PN 16;
and End DN 100, PN 25
Direct pulse output Connections
Polyketone blades
Horizontal rotor with long-life journal bearings Flow Range Normal 75-750 gpm (285-2,850 L/min.)
Extended 50-900 (190-3,400 L/min.)
Only three moving parts
Maximum 285 psi (19 bar) - 4" ANSI 150, Steel
Affordable: With the industrys focus on economics,
Working 362 psi (25 bar) - DN 100, PN 25, Steel
equipment value is more important than ever. By using Pressure
modern materials and manufacturing methods, PRIME 4
makes the advantages of displacement meter technology Housing/ Meets the requirements of NFPA-30, ASME
available at an affordable price. Pressure B31.3, and German TUV Code and AD Techni-
Vessel cal Regulation of Pressure Vessel Design.
Polyketone blades which allow the meter to run at higher For other requirements consult factory.

speeds with smaller parts


Operating -20F to 150F (-29C to 65C)
Direct pulse output which replaces the more expensive
Temperature
pulse transmitter Range

Weight 310 lb (140 kg.)


8.4"
9.6" (213) 5.0" Accuracy Repeatability - better than 0.02%
16.0" (128)
(406)
(243)
Thermal 8.0" Linearity - better than 0.15% over normal
3.7" Well (203)
(94) flow range
9.0"
(229)

Stability - better than 0.05% per 10 million


8.3" gallons (38 million litres)
(221)
12.9"
22.9" (328) 10.8"
(583) (274) 1.3" Electrical Pulse output
(33)
50 pulses per gallon (13 pulses per litre)
Line driver type
7.7" Dual pulse quadrature (optional)
(196)

Drain
7.3" 7.3"
Materials Housing and cover - steel
(186) .500-13 UNC-2B
(186)
(2 Places) Blades - reinforced polyketone
Rotor - cast iron
Horizontal Installation Shown Cam - superhardened steel

Vertical Installation PRIME 4 can also be configured for vertical


installation with the same relative dimensions as shown for the
horizontally configured meter.
USA Operation
1602 Wagner Avenue
Erie, Pennsylvania 16510 USA
P:+1 814.898.5000
FMC Technologies
Measurement Solutions, Inc. Germany Operation
500 North Sam Houston Parkway West, Smith Meter GmbH
www.fmctechnologies.com/measurementsolutions Suite 100 Regentstrasse 1
Houston, Texas 77067 USA 25474 Ellerbek, Germany
2013 FMC Technologies. All rights reserved. SF01014 Issue/Rev. 0.6 (3/13) P:+1 281.260.2190 P:+49 4101 304.0
2