Sie sind auf Seite 1von 4

Epoxy mortar FIS EB

Chemical fixings
The basic epoxy mortar for applications in concrete

BUILDING MATERIALS APPROVALS


Approved for anchorings in:
Concrete C20/25, cracked and non-
cracked

ADVANTAGES APPLICATIONS FUNCTIONING


FIS EB is approved for use in cracked Heavy steel constructions The epoxy mortar FIS EB combined
concrete and for rebar applications Consoles with the threaded rod FIS A is
and achieves a good performance in Silo installations suitable for pre-positioned and push-
these applications which enables an Tall shelving through installation.
economical use of injection mortar. Post-installed rebar connections Resin and hardener are stored in two
Variable anchorage depths from 4xd separate chambers and are not
to 20xd allow for ideal adaptation to mixed and activated until extrusion
the load to be applied. through the injection capsule in the
FIS EB can be used in various static mixer.
conditions (dry/wet concrete, The mortar is injected bubble-free
flooded hole), thus working in almost from the drill hole base.
all situations on the building site and The mortar bonds the entire surface
making it a safe and reliable system. of the anchor rod with the drill hole
wall and seals off the drill hole.
The anchor rod is set manually by
slightly rotating it until it reached the
drill hole base.
During push-through installation, the
annular gap between the anchor rod
and the attachment is filled with FIS
EB.

TECHNICAL DATA

Epoxy mortar FIS EB

http://www.fischer.ae/ - 06/09/2016 1
Epoxy mortar FIS EB

Chemical fixings
ETA-approval
Languages on the Contents Sales unit
cartridge

Article name Art.-No. [pcs]


FIS EB 390 S 534984 GB, E, P 1 cartridge 390 ml, 2 x FIS 6
MR
FIS EB 390 S 534985 TR, RUS, KR 1 cartridge 390 ml, 2 x FIS 6
MR
FIS EB 585 S 534986 GB, E, P 1 cartridge 585 ml + 2 x FIS 6
UMR

http://www.fischer.ae/ - 06/09/2016 2
Accessories
Epoxy mortar FISconcrete:
EB FIS A

LOADS

Chemical fixings
Injection system FIS EB with threaded rod FIS A (property class 8.8)
Highest permissible loads for a single anchor1) 6) in concrete C20/254)
For the design the complete assessment ETA-15/0440 has to be considered.
Cracked concrete Non-cracked concrete
Type Min. Max. Min. Max. Per- Per- Min. Min. Per- Per- Min. Min.
eective eective member torque missible missible spacing edge missible missible spacing edge
anchorage anchorage thickness moment tensile shear distance tensile shear load distance
depth depth load load load
hef,min hef,max hmin Tinst,max Nperm3) Vperm3) smin2) cmin2) Nperm3) Vperm3) smin2) cmin2)
[mm] [mm] [mm] [Nm] [kN] [kN] [mm] [mm] [kN] [kN] [mm] [mm]
60 100 10,0 3,6 7,2 40 40 7,9 8,4 40 40
FIS A M8 (8.8)
160 190 10,0 9,6 8,4 40 40 13,9 8,4 40 40
60 100 20,0 4,5 9,0 45 45 9,0 13,3 45 45
FIS A M10 (8.8)
200 230 20,0 15,0 13,3 45 45 22,1 13,3 45 45
70 100 40,0 6,3 12,6 55 55 12,6 19,3 55 55
FIS A M12 (8.8)
240 270 40,0 21,5 19,3 55 55 32,1 19,3 55 55
80 116 60,0 7,7 15,3 65 65 17,2 34,4 65 65
FIS A M16 (8.8)
320 356 60,0 30,6 35,9 65 65 59,8 35,9 65 65
90 138 120,0 10,8 21,5 85 85 20,5 41,1 85 85
FIS A M20 (8.8)
400 448 120,0 47,9 56,0 85 85 93,3 56,0 85 85
96 152 150,0 13,4 32,2 105 105 18,8 45,2 105 105
FIS A M24 (8.8)
480 536 150,0 71,8 80,7 105 105 114,9 80,7 105 105
108 168 200,0 16,0 38,5 120 120 22,5 54,0 120 120
FIS A M27 (8.8)
540 600 200,0 90,9 104,9 120 120 136,3 104,9 120 120
120 190 300,0 18,8 45,1 140 140 26,3 63,2 140 140
FIS A M30 (8.8)
600 670 300,0 112,2 128,2 140 140 168,3 128,2 140 140
1) 4)
The partial safety factors for material resistance as regulated in the assessment and TR029 as For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
well as a partial safety factor for load actions of L = 1,4 are considered. As an single anchor 6)
The given loads are valid for temperatures in the substrate up to +50 C (resp. short term up
counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x h ef. to 72 C). Erection of the drill hole by hammer drilling with best possible drill hole cleaning
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. according assessment. The anchor may be installed in dry or wet concrete.
3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see assessment.

http://www.fischer.ae/ - 06/09/2016 3
Accessories
Epoxy mortar FIS EB concrete: FIS A

LOADS

Chemical fixings
Injection system FIS EB with threaded rod FIS A (property class A4-70)
Highest permissible loads for a single anchor1) 6) in concrete C20/254)
For the design the complete assessment ETA-15/0440 has to be considered.
Cracked concrete Non-cracked concrete
Type Min. Max. Min. Max. Per- Per- Min. Min. Per- Per- Min. Min.
3 eective eective member torque missible missible spacing edge missible missible spacing edge
anchorage anchorage thickness moment tensile shear distance tensile shear load distance
Chemical xings

depth depth load load load


hef,min hef,max hmin Tinst,max Nperm3) Vperm3) smin2) cmin2) Nperm3) Vperm3) smin2) cmin2)
[mm] [mm] [mm] [Nm] [kN] [kN] [mm] [mm] [kN] [kN] [mm] [mm]
60 100 10,0 3,6 5,9 40 40 7,9 5,9 40 40
FIS A M8 (A4-70)
160 190 10,0 9,6 5,9 40 40 9,8 5,9 40 40
60 100 20,0 4,5 9,0 45 45 9,0 9,3 45 45
FIS A M10 (A4-70)
200 230 20,0 15,0 9,3 45 45 15,5 9,3 45 45
70 100 40,0 6,3 12,6 55 55 12,6 13,5 55 55
FIS A M12 (A4-70)
240 270 40,0 21,5 13,5 55 55 22,5 13,5 55 55
80 116 60,0 7,7 15,3 65 65 17,2 25,2 65 65
FIS A M16 (A4-70)
320 356 60,0 30,6 25,2 65 65 42,0 25,2 65 65
90 138 120,0 10,8 21,5 85 85 20,5 39,3 85 85
FIS A M20 (A4-70)
400 448 120,0 47,9 39,3 85 85 65,5 39,3 85 85
96 152 150,0 13,4 32,2 105 105 18,8 45,2 105 105
FIS A M24 (A4-70)
480 536 150,0 71,8 56,6 105 105 94,4 56,6 105 105
108 168 200,0 16,0 38,5 120 120 22,5 54,0 120 120
FIS A M27 (A4-70)
540 600 200,0 90,9 73,6 120 120 122,7 73,6 120 120
120 190 300,0 18,8 45,1 140 140 26,3 63,2 140 140
FIS A M30 (A4-70)
600 670 300,0 112,2 89,9 140 140 150,0 89,9 140 140
1) 4)
The partial safety factors for material resistance as regulated in the assessment and TR029 as For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
well as a partial safety factor for load actions of L = 1,4 are considered. As an single anchor 6)
The given loads are valid for temperatures in the substrate up to +50 C (resp. short term up
counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x h ef. to 72 C). Erection of the drill hole by hammer drilling with best possible drill hole cleaning
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. according assessment. The anchor may be installed in dry or wet concrete.
3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see assessment.

LOADS
Injection system FIS green with threaded rod FIS A (property class 5.8)
Highest permissible loads for a single anchor1) 6) in concrete C20/254)
For the design the complete approval ETA-14/0408 has to be considered.
Non-cracked concrete
Type Min. eective Max. eective Min. member Max. torque Permissible Permissible Min. Min.
anchorage depth anchorage depth thickness moment tensile load shear load spacing edge distance
hef,min hef,max hmin Tinst,max Nperm3) Vperm3) smin2) cmin2)
[mm] [mm] [mm] [Nm] [kN] [kN] [mm] [mm]
60 100 10,0 6,3 5,1 40 40
FIS A M8 (5.8)
160 190 10,0 9,0 5,1 40 40
60 100 20,0 7,5 8,6 45 45
FIS A M10 (5.8)
200 230 20,0 13,8 8,6 45 45
70 100 40,0 9,9 12,0 55 55
FIS A M12 (5.8)
240 270 40,0 20,5 12,0 55 55
80 116 60,0 13,6 22,3 65 65
FIS A M16 (5.8)
320 356 60,0 37,6 22,3 65 65
90 138 120,0 16,8 34,9 85 85
FIS A M20 (5.8)
400 448 120,0 58,6 34,9 85 85
1) 4)
The partial safety factors for material resistance as regulated in the approval as well as a partial For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an 6)
The given loads are valid for temperatures in the substrate up to +50 C (resp. short term up
anchor with a spacing s 3 x h ef and an edge distance c 1,5 x h ef. to 80 C). Erection of the drill hole by hammer drilling with best possible drill hole cleaning
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. according approval. The anchor may be installed in dry or wet concrete.
3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.

160
http://www.fischer.ae/ - 06/09/2016 4