Specifications

Street Light T1A Series

Features
Modular pluggable technology, easy tool onsite maintenance;
Honeycomb briquette burning effect and the whole structure cooling
technology;
Double-coupling IP68 protection, highest waterproof level;
Metal structure, high mechanical strength;
Ergonomic light distribution to achieve uniform illuminating effect;
Free modular serialization and full power range solution.

Applications
Street lighting
Parking lots
Roadway lighting
Path lighting

Standard Colors
White
Gray
Black

Advantages

Air Convection Effect Whole-structure Heat Dissipation

Double-coupling IP68 Protection Tool-less Maintenance

High-efficacy LED Light Source Flexible Combinations of Modules


Electrical and Photometric Specification

Driving Luminous
Input Voltage Flux Power Power
Model Current Power (W) Efficacy Beam Angle LED Brand CCT (K) CRI
(V) (lm) Factor Efficiency
(mA) (lm/W)

700 40 1105 4400200

Type I, II, III, IV, Lumileds 3000,4000,


T1A-1 AC100-277 860 50 1055 5250250 0.95 89% >70
VS Luxeon T 5000,5700

1050 60 1005 6000300

700 80 1105 8800400

Type I, II, III, IV, Lumileds 3000,4000,


T1A-2 AC100-277 860 100 1055 10500500 0.95 91% >70
VS Luxeon T 5000,5700

1050 120 1005 12000600

700 120 1105 13200600

Type I, II, III, IV, Lumileds 3000,4000,


T1A-3 AC100-277 860 150 1055 15750750 0.95 91% >70
VS Luxeon T 5000,5700

1050 180 1005 18000900

700 160 1105 17600800


Type I, II, III, IV, Lumileds 3000,4000,
T1A-4 AC100-277 0.95 91% >70
VS Luxeon T 5000,5700
860 200 1055 210001000

700 200 1105 220001000


Type I, II, III, IV, Lumileds 3000,4000,
T1A-5 AC100-277 0.95 91% >70
VS Luxeon T 5000,5700
860 250 1055 262501250

700 240 1105 264001200


Type I, II, III, IV, Lumileds 3000,4000,
T1A-6 AC100-277 0.95 91% >70
VS Luxeon T 5000,5700
860 300 1055 315001500

700 280 1105 297001400


Type I, II, III, IV, Lumileds 3000,4000,
T1A-7 AC100-277 0.95 91% >70
VS Luxeon T 5000,5700
860 350 1055 367501750

Mechanical and Environmental Specification

Lumen Pole
Working Storage Housing
Model Maintenance Diameter Product Size (mm) Packing Size (mm) N.W (kg) G.W (kg)
Environment Temperature Material
(h) (mm)

T1A-1 490*330*91 590*430*170 5.5 6.7

T1A-2 595*330*91 690*430*170 7.0 8.3

T1A-3 695*330*91 790*430*170 8.2 9.6

T1A-4 -40+50, 775*330*91 870*430*170 9.8 11.3


Aluminum
10% -40+50 >50,000 57-63
Alloy
90%RH 850*330*91 950*430*170 10.8 12.2
T1A-5
915*330*91 1010*430*170 12.0 13.5

T1A-6 1030*330*91 1130*430*170 12.7 14.4

T1A-7 1110*330*91 1210*430*170 14.2 16

4
Lighting Distribution

T1S3501 T1S3100 T1S1810 T2M3702


IESNA Type I Short IESNA Type I Short IESNA Type I Short IESNA Type II Medium

T3M3910 T3M2701 T4M5703 T5S3040


IESNA Type III Medium IESNA Type III Medium IESNA Type IV Medium IESNA Type Vs Short

T1A
Dimensions

850
775
695
595
490

330 91 330 91 330 91 330 91 330

T1A T1A-1

T1A
T1A-2 T1A-3 T1A-4
1110
1030

1110
1030
915
850

850
775

775
695

30 91 91 330 330 91 91 330 330


330 9191 91 330 330 91 91 330 91

T1A-5 T1A-5 T1A-6 T1A-7


Installation

Step 1: Loosen the 2 screws at the rear cover, then remove the rear cover;
Step 2: Loosen the 4 screws on the 2 arched clamps, insert and fix the cross arm under the 2 arched clamps, and then
tighten the 4 screws;
Step 3: Connect the wires to the AC wires.(The earth wire should be reliable and linked to the ground);
Step 4: Fix the rear cover back to the lamp and tighten the 2 screws on it.

Maintenance

Step 1: Loosen the 2 screws at the back cover, then open the back cover;
Step 2: Loosen the screws at both ends of the failed module(s)/driver(s);
Step 3: Disconnect the waterproof connectors to the failed module(s)/driver(s);
Step 4: Take out the failed module(s)/driver(s);
Step 5: Replace the failed module(s)/driver(s) with qualified one(s),and then tighten the screws at the ends and the waterproof connectors;
Step 6: Close the back cover and then tighten up the 2 screws on it.
Specifications
Street Light TT1A Series

Installation

1. Pull the two latches at side, then 2. Loosen the four screws on the 3. Connect the ground wire, neutral
open the cover. mounting bracket. wire and live wire to the AC input
(make sure it sufficiently grounded).

4. Insert the pole to the lamp after 5. Tighten up the screws on the 6. Close the cover, then press and
connecting the wire. mounting bracket. fasten the latches.
Specifications
Street Light T1A Series

Maintenance
Driver & Electrical Parts

1. Pull the two latches at side, then 2. Disconnect the driver from the AC 3. Unscrew the screws at ends of the
open the cover. input. driver.

4 Unscrew the waterproof connector to 5. Replace the failed driver with a new 6. Close the cover. Then press and
the driver one. Tighten up all the screws and the fasten the latches.
connector. Re-connect to the wires of
AC input.
Specifications
Street Light T1A Series

Module

1. Pull the two latches at side, then 2. Unscrew the two screws at ends of 3. Unscrew the waterproof connector to
open the cover. the failed module. the failed module.

4. Take out the failed module and 5. Align and tighten up the connector, 6. Close the cover. Then press and
replace with a new one. and the screws for the new module. fasten the latches.
Specifications
Street Light T1A Series

Connectors Operation Guide

Spin the male terminal clockwise. When the male indicatrix points between indicatrix female #2 and #3, and the gap
between male and female terminals is extremely small, the connectors are well connected; otherwise, there will be risks in
its waterproof performance.

When the gap between male and female terminals is extremely small, if any looseness can be sensed, please spin the male
terminal clockwise until tight.