Heat Load Calculations

1. Space to be cooled
Length : 5.25 m
Width : 4.15 m
Area : 21.79 m2
BTU required : 7,329 BTU/hr

2. Heat generated by occupants


Assumed no of workers : 3 pax
Assumed no of customers : 5 pax
Total occupants : 8 pax
BTU required : 4,800 BTU/hr

3. Heat generated by machinery


Freezer - 2 door : 1.1 kW
Chiller - 3 door : 1.2 kW
Display chiller : 1.2 kW
Total input power : 3.5 kW
BTU required : 4,900 BTU/hr

4. Heat generated by lighting


12W LED double grill : 0.06 kW
15W LED strip light : 0.45 kW
6W LED pendant lamp : 0.018 kW
18W 4ft LED T5 light : 0.18 kW
3W signage LED light : 0.003 kW
2W ceiling emergency light : 0.002 kW
Total lighting input power : 0.713 kW
BTU required : 3,030 BTU/hr

5. Total BTU required : 20,059 BTU/hr