Beruflich Dokumente
Kultur Dokumente
Release 4.0
www.siemens.com/healthcare
ACUSON X300 Ultrasound System
Premium Edition
GENERAL INFORMATION
The ACUSON X300 ultrasound system, premium
edition (PE) is a portable, compact, fully shared
service imaging solution. The ACUSON X300 PE
delivers exceptional clinical performance across a
wide variety of applications and streamlines exam
workflow with an easy-to-use ErgoDynamic
imaging system design.
4
- Up to two PW Doppler frequencies in color,
power or pulsed wave modes
- One frequency in SCW Doppler mode
Beamforming in 2D-Mode
New generation all-digital beam former
technology enables parallel Quad beam processing
of the RF signal data in the time and amplitude
domains
2D-mode line density up to 512 lines
Up to 2,240 processing channels
Total system dynamic range > 199 dB
Focusing
Up to 4 transmit focal zones
Digital dynamic receive focusing with dynamic 2D Image Display
apodization Full screen, Curved Vector, Split, Quad and
Dual Select screen formats
SynAps Synthetic Aperture Technology
L/R flip and U/D flip for all formats in real-time
SynAps synthetic aperature technology is
and digital cine replay
available on the CH5-2, C8-5, VF8-3 and VF10-5
Split/Zoom
transducers for higher image resolution at depth
Dual image display from freeze
User can turn SynAps technology On and Off
Image depth from 2 cm to 30 cm in 1.0 cm
2D-mode Image Processing increments transducer dependent
All-digital parallel signal processing with frame Virtual Format Imaging (transducer dependent)
rates up to 1001fps transducer dependent - Left/right steer
MultiHertz multiple frequency imaging with up - Trapezoid Imaging
to seven user selectable transmit frequencies Digital read/write zoom with image pan
Six levels Res/Speed selection: 0 5 - Available on live and cine replay images
Five persistence levels: 0 4 - At least 2.5x and up to 10x zoom transducer
Four edge enhancement levels: 0 3 dependent
Display dynamic range: 30 to 70 dB in five 4B mode
decibel increments
2D Calipers Generic Measurements and
Adjustable gain from 0 to 60 dB in one decibel
Calculations
increments
Multiple cursor sets on frozen, live, dual screen
DTO technology 3 levels
and cine playback images
Eight DGC controls for Depth Gain Compensation
Up to eight distance measurements per screen
Nine gain balanced user-selectable gray maps
Distance measurement
16 user-selectable 2D colorization maps
Depth measurement from skin line
Maximum Depth: 30 cm with CH5-2, P4-2
Angle measurement
and P5-1
Area and circumference: ellipse, trace
Minimum Depth: 2 cm with VF13-5SP
5
Compound Measurements: PRF range: 1.56 kHz to 34.7 kHz Sample Rate
- Volume: user-selectable preset by 1 distance, Velocity scale range is 30 ~ 650 cm/sec with 0
2 distance, 3 distance; 1 ellipse and 1 degree angle correction
distance Eight wall filter selections transducer
- Flow volume: 1 velocity and 1 distance, or 1 dependent
velocity and 1 ellipse 17 levels of baseline shift
- Stenosis: user-selectable preset calculated by Spectral invert
2 ellipse, or 2 distance measurements Autotrace function is not supported in
SCW mode
Pulsed Wave Spectral Doppler
Available on all imaging array transducers SCW and Spectral Doppler Display
Up to two user-selectable transmit frequencies Full screen Doppler trace, 2D/Doppler mode,
per transducer triplex or update 2D/C/Doppler
DTI Doppler tissue imaging available on select Four imaging display formats top-bottom:
transducers 1/3-2/3, 1/2-1/2, 2/3-1/3; side-by-side: 40-60
Eight sweep speed selections: 1, 2, 3, 4, 5, 6, 7, 8
Doppler Calipers Generic Measurements and
Eight selectable post-processing gray maps
Calculations
12 user-selectable Doppler colorization maps:
Multiple cursor sets on frozen and cine
0 11
playback images
Adjustable gain from 0 to 90 dB in one decibel
Velocity/Frequency/Pressure Gradient
increments
Heart rate/Heart cycle/Time
PRF range: 100 to 19,500 Hz
Autotrace measurements and calculations
Velocity scale range is 1.5 ~ 350 cm/sec
including PS, ED, TAMx, TAMn, PI, RI and S/D
with 0 degree angle correction
Resistive Index (RI)
Angle correction 0 - 89 degree in one degree
Pulsatility Index (PI), including Peak-to-Peak
increments
method
Gate size: from 1.0 mm up to 20 mm
Time Average Velocity max (TAV)
Eight wall filter selections transducer dependent
Systolic/diastolic ratio (S/D)
17 levels of baseline shift
Velocity Time Integral (VTI)
Spectral invert
Acceleration/Deceleration
Autotrace function
Flow volume using combined velocity and
Steerable Continuous Wave (SCW) Doppler distance, or velocity and ellipse measurements
Available on all phased array transducers when Doppler angle correction after measurement
basic cardiac package is purchased
Color Doppler Velocity Imaging
One transmit frequency
Available on all imaging array transducers
Eight sweep speed selections: 1, 2, 3, 4, 5, 6, 7, 8
MultiBeam Formation technology provides
Eight selectable post processing gray maps
quad signal processing for color Doppler frame
12 user-selectable Doppler colorization maps:
rates up to 171 fps transducer dependent
0 11
DTI capability imaging available on select
Adjustable gain from 0 dB to 90 dB in
transducers
one decibel increments
6
Left/right steer on all linear transducers Four levels of power smoothing
Advanced processing in color mode resulting in Five tissue/color priority selections
excellent spatial resolution and superior Flash Five color persistence levels
suppression
Color and Power Doppler Display
Up to two user-selectable transmit frequencies
2D/C mode, Split 2D-2D/C mode
per transducer
Dual real-time 2D/C mode
Up to nine user-selectable color velocity maps
2D/C/D mode (simultaneous triplex), 2D/C/D
(seven velocity and two velocity/variance)
mode (update)
Velocity scale range: 0.6~244.4 cm/sec
PRF scale range: 100 Hz to 19,500 Hz M-Mode
transducer dependent Available on all imaging array transducers
Adjustable gain from -20 dB to 20 dB in one Anatomical M-mode live, cineloop and
decibel increments DIMAQ image review
Six color line density selections Up to five user-selectable, including fundamental
Four wall filter selections and harmonics
Four levels of color smoothing Four edge enhancement selections
Five tissue/color priority selections Display dynamic range: 30 dB to 70 dB in five
Five color persistence levels decibel increments
Color invert Adjustable gain from 0 dB to 60 dB in one decibel
Velocity tag increments
Peak hold: Off, 1 sec, 2 sec, and 3 sec Nine user-selectable gray maps
AutoColor flow state optimization with high, 16 user-selectable M-mode colorization maps
medium and low flow settings Eight sweep speed selections: 1, 2, 3, 4, 5, 6, 7, 8
7
FREEZE, CINE AND CINE
POST-PROCESSING FUNCTIONS
Cine Review
Cine feature is standard and offers post-acquisition
optimization of all real-time post-processing
functions.
Frame-by-frame cineloop review and continuous
cine motion review, including control of playback
rate
Independent cine review in mixed modes
(2D/M, 2D/Doppler, 2D/C/Doppler)
Independent cine review in 2D Dual Select
mode with image align playback feature
Maximum Standard Cine Memory is up to
M-mode
2729 frames
- Gray map
Acoustic clip capture from cine review
- M-mode colorization map
Retrospective clip capture during real-time
- Measurements/reports/annotations/pictograms
imaging with a selectable duration of 1, 2, 3,
or 4 seconds or a selectable duration 1, 2, 3 TRANSDUCER TECHNOLOGY
or 4 beat capture; ECG triggerable
Prospective clip capture during real-time Ultra-sensitive, wideband transducers, matched with
imaging with a selectable duration of 1 to user-selectable MultiHertz imaging, improve
120 seconds a selectable duration 1 to 120 resolution and penetration. Depending on the
beat capture; ECG triggerable transducer, the user can select up to seven 2D and
Anatomical M-mode live, cineloop and THI frequencies and up to two color and spectral
DIMAQ image review Doppler frequencies, expanding the clinical
versatility of a single transducer, and thereby
Post Processing Features in Freeze Frame or Cine maximizing transducer investment.
D-mode Wideband MultiHertz imaging allows user
- Zoom/pan selection of independent 2D and color
- Gray map frequencies for optimal resolution and
- 2D-mode colorization map penetration
- Measurements/reports/annotations/pictograms Universal, stainless steel and disposable biopsy
Color guides for specified linear and curved array
- Zoom/pan transducers
- Color map Innovative ultra low-loss lens materials and
- Color invert microelectronic technologies for efficient
- Measurements/reports/annotations/pictograms performance and increased signal bandwidth
Doppler Frequency range: 1.2 MHz to 13 MHz
- Gray map Hanafy Lens acoustic technology
- Doppler colorization map Single crystal piezoelectric design
- Angle correct microCase transducer miniaturization
- Measurements/reports/annotations/pictograms technology and SuppleFlex cables
8
Intracardiac echocardiography transducers Abdomen
ACUSON AcuNav 10F ultrasound catheter All general measurements and calculations
Adult intracardiac echocardiography Physician summary utility supports on-system
ACUSON AcuNav 8F ultrasound catheter report generation including customizable
Adult intracardiac echocardiography letterhead, patient data, results, graphs,
images, comments, recommendations, and
Note: See dedicated transducer flyer for more information. customizable signature line
Cerebrovascular Thyroid
All general measurements and calculations All general measurements and calculations
ICA prox, ICA mid, ICA dist, ECA and VA Thyroid volume
measurements Physician summary utility supports on-system
Area Percent Stenosis and Diameter Percent report generation including customizable
Stenosis measurements letterhead, patient data, results, graphs,
Cerebrovascular patient report images, comments, recommendations, and
Physician summary utility supports on-system customizable signature line
report generation including customizable
Urology
letterhead, patient data, results, graphs,
All general measurements and calculations
images, comments, recommendations, and
Residual volume calculations
customizable signature line
Prostate and urology patient report
Physician summary utility supports on-system
report generation including customizable
letterhead, patient data, results, graphs,
images, comments, recommendations, and
customizable signature line
10
Testicle
All general measurements and calculations
Physician summary utility supports on-system
report generation including customizable
letterhead, patient data, results, graphs,
images, comments, recommendations, and
customizable signature line
Musculoskeletal
All general measurements and calculations
Right and left hip angle measurement
Classification and Graf Sonometer
Hip angle patient report
Physician summary utility supports on-system
report generation including customizable
letterhead, patient data, results, graphs, Emergency Medicine Calculations
images, comments, recommendations, and FAST Focused Acute Sonography in Trauma
customizable signature line reporting elements to support emergency
medicine utility
TCI Aorta essential aorta measurements and
All general measurements and calculations reporting elements to support emergency
MCA, ICA-Siphon, ACA-A1, ACA-A2, ACoA, medicine clinical utility
PCA-P1, PCA-P2, PCoA, PCA, Basilar A and Vert OB subset of essential OB measurements and
A measurement reporting elements to support emergency
TCI patient report medicine clinical utility
Physician summary utility supports on-system Physician summary utility supports on-system
report generation including customizable report generation including customizable
letterhead, patient data, results, graphs, letterhead, patient data, results, graphs,
images, comments, recommendations, and images, comments, recommendations, and
customizable signature line customizable signature line
Penile
All general measurements and calculations
Corp Cav, Corp Spong, Cav A, Pre-Inj Cav A, DIGITAL PATIENT STUDY STORAGE
Post-Inj Cav A and Urethra B mode measurement AND ARCHIVING
Iliac A, Dorsal A, Urethral A, Bulbar A, Brach A,
The DIMAQ-IP integrated workstation allows for
Cav A, Pre-Inj Cav A, Post-Inj Cav A, Sup Dorsal
digital acquisition, storage and review of com-
V and Dp Penile V D mode measurement
plete ultrasound studies, including static images
Penile patient report
and dynamic clips, measurements, calculations
Physician summary utility supports on-system
and reports.
report generation including customizable
letterhead, patient data, results, graphs,
images, comments, recommendations, and
customizable signature line
11
Patient Study Management OPTIONS
Playback of digitally stored images in a selectable
1-up, 4-up, 9-up, 16-up or 25-up screen format. DICOM 3.0 Connectivity (Option)
The patient study screen allows searching, selecting Enables digital data transfer via a DICOM network
and deleting studies, and exporting studies to for both printing and storage. The ACUSON X300
DVD multi-drive (DVD-R/RW and CD-R/RW) PE acts as a DICOM Storage Class User and DICOM
100 GB internal hard drive reserved for Print Class User.
patient data management
Functionality supported:
Compatible with removable 650 MB, 700 MB
Connectivity to PACS system for storage of all
and 790 MB CD-R and 650 MB or 700 MB CD-RW
digital images and dynamic clips with patient
Removable 4.7 GB single layer DVD and
demographic data
8.5 GB single side double layer DVD
In-Progress Store during the exam
Hard drive capacity:
Image printing to DICOM color and
- Approximately 150,000 B/W and color
grayscale printers
images
DICOM Storage Commitment
Storage and retrieval of frozen static images
DICOM Exchange Media export to DVD-R/RW
Storage and retrieval of reports
and CD-R/RW
Instant dial-in and replay of static images
DICOM Region Calibration
in 1-up screen format
DICOM interchange media viewer software
Supports measurements and calculations on
SHOWCASE
archived study and on saved and retrieved
Interchange media database that identifies the
images
CD to which the patient study has been burned
Acoustic clip capture from cine review
Retrospective clip capture during real-time DICOM Modality Worklist (Option)
imaging with a selectable duration of 1, 2, 3 Enables query and direct download of the patient
or 4 seconds or a selectable duration of 1, 2, worklist schedule from the Hospital/Radiology
3 or 4 beat capture; ECG triggerable Information System (HIS/RIS) to the ACUSON
Prospective clip capture during real-time X300 PE, automatically populating the "New
imaging with a selectable duration of 1 to Patient" screen with patient demographic
120 seconds or a selectable duration of 1 to information. (Requires DICOM 3.0 Connectivity
120 beat capture; ECG triggerable option.)
Export of patient studies from hard drive to
DVD-R/RW and CD-R/RW drive. Studies can be DICOM MPPSModality Performed Procedure
individually selected Step (Option)
Images are exported in PC compatible TIFF Enables automatic exchange of Modality
format, AVI format, or DICOM format Performed Procedure Step information with the
M-mode Still Frame Scroll and Store Hospital/Radiology Information System (HIS/RIS).
PW Spectral Doppler Still Frame Scroll and Store (Requires DICOM 3.0 Connectivity option and
Patient database sorting by Name, ID, and DICOM Modality Worklist option.)
Study Date
USB Flash Drive
12
DICOM OB/GYN Structured Reporting (Option) Tissue Grayscale Optimization (TGO) (Option)
DICOM Structured Reporting (SR) provides a TGO tissue grayscale optimization technology
standardized report architecture to allow for easy provides one-button image optimization. It
transfer of OB and GYN measurements to offline automatically adjusts image brightness to the
PCs, workstations and archiving systems. DICOM tissue type being imaged and equalizes the overall
OB/GYN Structured Reporting will automatically image gain. The user definable threshold accom-
populate OB/GYN measurements to their respective modates different user preferences for gain
fields in an external software package. (To send settings and various room lighting conditions. TGO
the OB/GYN SR data over the network, the DICOM technology improves the consistency and quality
3.0 connectivity option is required.) of ultrasound imaging to enhance productivity by
removing time-consuming and operator dependent
DICOM Vascular Structured Reporting (Option)
manual adjustments. TGO technology can be used
DICOM Structured Reporting (SR) provides a
with every transducer, for every exam type and at
standardized report architecture to allow for easy
every imaging frequency, including THI.
transfer of Vascular measurements to offline PCs,
workstations and archiving systems. DICOM fourSight 4D transducer technology (Option)
Vascular Structured Reporting will automatically fourSight 4D technology provides 2D and 3D
populate Vascular measurements to their respective imaging utilizing mechanical acquisition, as well as
fields in an external software package. (To send real-time 4D imaging, up to 30 volumes per
the Vascular SR data over the network, the DICOM second, with the C7F2 and the EV9F4 4D transducers.
3.0 connectivity option is required.) The fourSight 4D imaging option offers an easy-
to-use interface for rapid acquisition and volume
DICOM Cardiac Structured Reporting (Option)
rendering and includes the following:
DICOM Structured Reporting (SR) provides a
Curved VOI
standardized report architecture to allow for easy
4D cine
transfer of Cardiac measurements to offline PCs,
MPR Measurements
workstations and archiving systems. DICOM
3-Scape real-time 3D imaging is supported
Cardiac Structured Reporting will automatically
on the following transducers: CH5-2, C6-2,
populate Cardiac measurements to their respective
EV9-4
fields in an external software package. (To send
the Cardiac SR data over the network, the DICOM Advanced fourSight technology (Option)
3.0 connectivity option is required.) Advanced fourSight technology offers broad
3D/4D acquisition, data rendering and post-
QuikStart (Option)
processing functionality.
QuikStart reduces time required for power-up and
MultiSlice format allows the user to select
power-down events by allowing the system to
range, slice spacing and format for viewing
enter a specialized suspend mode.
each slice. The MultiSlice format supports up
Standby mode power-down in 3 sec; complete
to 36 slices at once.
boot-up in less than 12 sec
Thick Slice Imaging (TSI) enables definition of
Standby time: more than 40 min
a view plane and creates a thick slice around
Full recharge in less than 180 min
the region of interest. TSI delivers improved
contrast resolution and provides more
information in a single image.
13
Curved MPR enables real-time multiplanar SieClear multi-view spatial compounding
reformatting of images into any linear or (Option)
curved plane. This permits the user to set The SieClear compounding option increases con-
points along a curved object in order to bring trast resolution and improves tissue differentia-
all objects along this line into the same plane tion of low contrast lesions by reducing image
for viewing, such as the Fetal Spine. speckle. Tissue boundaries and interfaces appear
sharper and more continuous. SieClear com-
Cardiovascular (Option)
pounding is accessible in THI and is compatible
Contains the prerequisites to perform cardiac and
with other advanced imaging options including
certain vascular exams:
SieScape panoramic imaging, TGO ultrasound
Physiological interface
technology and Clarify VE technology.
- Standard 3-lead ECG interface
- R-Wave single and dual trigger function Clarify vascular enhancement (VE) technology
- Heart rate display (Option)
- Adjustable gain and trace position on screen Clarify VE technology is a real-time, adaptive,
- Selection for external ECG input pixel-by-pixel analysis implemented through a
Steerable Continuous Wave Doppler module simple, time-saving user interface that provides
Auxiliary Continuous Wave Doppler module multiple levels of clarification to optimize tissue
contrast resolution and definition of both tissue
Spectral and Color Doppler Tissue Imaging
and vessel walls according to user preference.
(DTI) (Option)
Clarify VE technology is available on all curved
Provides color DTI and spectral DTI exams
and linear transducers.
with quantification package
Spectral DTI with quantification package SieScape Imaging (Option)
Enables assessment of LV diastolic function B/W panoramic imaging allows acquisition and
on the ACUSON X300 PE display of images up to 60 cm in length to a
- Requires the P5-1, P4-2, P8-4, V5Ms or maximum curvature of 360 degrees.
ACUSON AcuNav ultrasound catheter Available on all curved and linear transducers
(8/10 french) transducers Can be displayed in full length or zoomed for
- Spectral Doppler DTI capability utilizes detail viewing
real-time Doppler shift information from Measurements available
moving tissue to better visualize and
Physio Module (Option)
quantify myocardial diastolic function
The Physio Module provides the ability to configure
- The spectral Doppler DTI calculation pack-
ECG capabilities for specialty applications that do
age provides guided velocity and acceleration
not require continuous wave Doppler capabilities.
measurements and includes a measurement
report package
- Color DTI capability can be used for
qualitative evaluation of wall motion and
displays the relative change of velocities
- Color DTI M-mode
14
OPTIONAL APPLICATIONS syngo fourSight TEE View (Option)
An integrated method which provides acquisition,
Stress Echo Imaging (Option) review, manipulation and dynamic display
The stress echo package provides tools for ECG capabilities of gated 3D datasets using the V5M
triggered acquisition, display, selection compari- transesophageal transducer.
son, evaluation and archiving of multiple cardiac 3D surface (volume) rendering for detailed
loops during various stages of a stress echo anatomical display
examination. Dart navigation tool with adjustable indicator
Standard acquisition protocols for treadmill, for line of sight direction for intuitive navigation
ergometric, and pharmacological stress Utilizes two cut planes positioned
including: perpendicular to the selected line of site
- Multiple factory default stress echo protocols Dynamic MultiPlanar reconstruction
- Customizable stress echo protocols Viewing presentation enhanced by zoom,
- Prospective and retrospective capture available pan and rotate functions
- Flexible combination of imaging modes Easy to use, rapid acquisition, enhanced
while in stress echo package workflow
- Ability for customized studies through
Protocol Editor, with up to 12 stages, 6 syngo Mitral Valve Assessment (MVA) (Option)
views per stage, 20 loops per view or 120 An integrated method which, in conjunction with
second prospective clip capture syngo fourSight TEE view, enables a detailed
Full screen or ROI (region of interest) acquisition assessment of mitral valve morphology from 3D
Complete R-R capture with clip editing images for a more accurate and complete diagnosis
Easy workflow throughout the exam protocol of pathology location and size. Performs measure-
Stage Timer ments for:
Prospective continuous capture (up to 120 Angle
seconds) or Retrospective labeled capture Size
Reference image display during acquisition Distance
Immediate review of acquired loops Area
Flexibility to skip views or stages
syngo Arterial Health Package (AHP) (Option)*
Flexibility to re-acquire and overwrite
syngo Arterial Health Package (AHP) features
already acquired images
a semi-automated carotid intima-media thickness
Indication of current view, acquired views
(CIMT) measurement capability integrated with
and skipped views in the workflow diagram
protocol driven measurements based on the ARIC
Wall Motion Scoring, 17-segment model with
study to generate an assessment of Vascular Age
graphical display and report printing
as well as an integrated calculation of Framingham
LV Volume Measurements with report
Risk to assist cardiovascular specialists in evaluat-
printing
ing arterial health. This noninvasive assessment
Factory default or user
tool can support physician and patient communica-
tion, help physicians identify atherosclerosis in its
earliest stages and help health care professionals
deliver preventative care.
1
ARIC - G Howard, et al: "Carotid artery intimal-media thickness distribution in general populations as
evaluated by B-mode ultrasound, ARIC Investigators": Stroke 1993;24;1297-1304
16
3D representations of parametric color M-mode syngo Auto Left Heart (Auto LH) Technology
display along the trace over time for: Calculated Confidence
- Selected components of Tissue Velocity - Uses progressive pattern recognition
- Tissue Strain technology based on a comprehensive
- Tissue Strain Rate database representing typical adult
- Pan, Zoom, Rotate of the 3D parametric display transthoracic exams
Time curves of global and segmental - Provides robust performance and expert-like
(6-segment model) LV volumes automatically consistency in every exam
calculated by Simpson method - Excels in technically difficult studies as
Parametric color display of automatically learning is largely independent of
calculated global and segmental Ejection image quality
Fraction Automated Workflow
Time curves and measurements of Dmin - Bypasses the cumbersome mark-and-trace
(transverse diameter) and Dmax (longitudinal method to calculate EF, end diastole volume
diameter) and end systole volume
Simultaneous display of volume time curves - Automatically identifies ED and ES frames
and measurements for current and previous and tracks endocardial borders frame to frame
cases - Promotes smooth, efficient workflow with
Synchrony analysis manual edit options
- 6-segment chamber model - Reduces observer variability to yield more
- Time curve display and measurements for consistent, standardized measurements
segmental tissue motion parameters: Velocity Consistent, Reliable and Convenient
(tangential or radial), Strain (tangential or - Extends calculation accuracy to broaden
radial), Strain Rate (tangential or radial) and clinical confidence
Displacement (tangential or radial) - Presents EF measurement in complete
- Automatic time-to-peak and phase analysis of perspective with image frames for ED
all motion parameter curves and ES with numerical and graphical data
- Parametric color 6-segment model display of - Available off the system with syngo
Time-to-Peak and phase information for US Workplace
Velocity (tangential or radial), Strain - Operates on DICOM clips from select Siemens
(tangential or radial), Strain Rate (tangential and non-Siemens ultrasound systems
or radial), Displacement (tangential or
Axius Edge Assisted Ejection Fraction (Option)
radial) and Rotation
Axius ejection fraction calculates left ventricle volumes
An arbitrary, multi-segment M-line can be
and ejection fractions quickly and reliably.
selected on a 2D clip display to obtain virtual
Enhances workflow by allowing the user to
M-mode information derived from a 2D clip.
indicate three boundary points for measurement
Virtual M-mode can be used as a background
instead of a manual trace of the ventricle
for time curves providing reference on cardiac
Utilizes the Simpson method for LV volume
cycle phase
calculations based on LV endocardial border
Compatible with standard acquisition frame
trace
rate clips, and acoustic clip capture (e.g., iso
volumetric contraction and relaxation events)
17
Intracardiac Echocardiography Imaging Options Two planes of bi-directional steering of the
(ICE) catheter tip (160 degrees in each direction:
Adult intracardiac echocardiography (ICE) using the anterior-posterior/left right) for maneuverability,
ACUSON AcuNav ultrasound catheter family. rapid anatomic orientation and micro-positioning
Disposable ACUSON AcuNav 8F ultrasound Longitudinal side-fire imaging provides
catheter standard echocardiographic views, similar
- 8 french catheter (cross-sectional diameter to TEE, for easier orientation
3.3 mm), 110 cm insertable length QuikSet user-programmable system parameters
Disposable ACUSON AcuNav 10F ultrasound provide instant image optimization
catheter Tension control knob for holding the desired
- 10 french catheter (cross-sectional diameter catheter curvature
2.7 mm), 90 cm insertable length 64-element digital phased array with
Ultrasound catheters must be purchased simultaneous processing for the highest
separately imaging resolution in all modes
Reuseable SwiftLink catheter connector (DL- Access to advanced imaging modes provides
260 type) (additional SwiftLink connectors full echocardiography capabilities, including:
are optional) - 2D imaging
10 sterile covers - M-mode
Complete echocardiography exam capabilities - Pulsed Wave (PW) spectral Doppler mode
during intracardiac minimally invasive - Continuous Wave (CW) spectral Doppler
procedures, such as atrial fibrillation ablation, mode
transcatheter septal closure device placement, - Color Doppler velocity capability
pacemaker lead placement, transseptal - DTI Doppler Tissue Imaging capability
catheterization, and balloon valvuloplasty (optional)
or septostomy - Comprehensive measurements and calculation,
Visualization of cardiac anatomy and regional including volume, function and hemodynamics
myocardial tissue motion, great vessels and MultiHertz imaging
vascular anatomy, blood flow direction and Zoom capabilities
velocity, other devices located within the heart
Sterile, steerable, single-use catheter
DOCUMENTATION DEVICES
SwiftLink catheter connector provides one-step Optional On-Board Video Devices
system-to-catheter set-up Up to two (B/W printer and color printer/DVD
High resolution, high frame rate imaging in Recorder) documentation devices can be
multiple modes, including: 2D, M-mode, PW integrated into the system cart and controlled
spectral Doppler, CW spectral Doppler, color from the system control panel
Doppler velocity and Doppler tissue imaging Supported devices:
(optional) - Mitsubishi USB P93DW B/W Printer
Digital phased array technology - Mitsubishi USB CP30DW Color Printer
not mechanical scanning - Sony USB UP-23MD Color Printer
Imaging penetration up to 15 cm allows for - JVC DVD BD-X201MS Recorder
visualization of left sided cardiac anatomy from (NTSC/PAL switchable, 115V/230V)
within the right atrium or right ventricle - Mitsubishi S-VHS VCR (NTSC and PAL versions)
18
SYSTEM INPUT/OUTPUT ELECTRICAL/ENVIRONMENTAL
SPECIFICATIONS
Video Standard
PAL/CCIR: 625 lines, 50 Hz The ACUSON X300 PE is available in one main-
NTSC/EIA: 525 lines, 60 Hz frame configuration, suitable for use in 100/115V
and 230V environments.
Video/Audio Input Power connections: 100-120/200-240 VAC,
(1) Composite color Video in, BNC-type 50/60Hz
(1) Y/C Video in, S-terminal (SVHS) Built-in AC isolation transformer
(1) 2-Channel Audio in (Right/Left), RCA Power consumption: maximum 600VA
jack type with OEMs
Atmospheric pressure range: 700 hPa to
Video/Audio Output
1060 hPa (525 to 795 mm Hg) or up to
(1) Composite B/W Video out, BNC-type
3050 m (10,000 ft)
(1) Composite color Video out, BNC-type
Ambient temperature range (without OEMs):
(1) RGB and Composite Sync out, mini D-SUB
10C to +40C (50 to 104F)
(15 pin)
Humidity: 30 80%, non-condensing,
(1) Y/C Video out, S-terminal (SVHS)
during operation
(1) 2-Channel Audio (Right/Left), RCA jack type
Maximum heat output: 2150 BTU/hr
(1) VGA out, mini D-SUB (15pin)
Other Input/Output
INTEGRATING THE HEALTHCARE
(1) Foot switch connector, phone jack-type
ENTERPRISE (IHE)
(1) Remote control connector, mini-jack Having all relevant information at one's fingertips
(stereo) is a prerequisite for optimal and efficient patient
care. Seamless integration of the hospitals IT and
System Interface Connections
Imaging Systems and their capabilities to exchange
Network
information without restriction are key success fac-
- (1) Ethernet connector, type RJ45
tors for facilitating daily work. This is why Siemens
(10/100 BaseT)
has been instrumental in launching and advancing
Peripherals
the IHE (Integrating the Healthcare Enterprise)
- (2) Serial port RS-232C connector, D-SUB (9-pin)
Initiative. Our commitment and dedication enable
- (2) USB 2.0 ports
us to provide clinicians with the ACUSON X300 PE
- (2) AC Main Outlet
one of many innovative products embedded with
SYSTEM DIMENSIONS the building blocks necessary in supporting clini-
cians' need for seamless health information
Height: 137.9 166 cm (54.43 65.3 in) exchange.
Width: 51.8 cm (20.4 in)
Depth: 87.9 cm (34.6 in) For more information on the ACUSON X300 PE
Weight: 102 kg (225 lbs)/98 kg without OEMs and the Siemens commitment to the IHE initiative,
please visit www.siemens.com/IHE.
19
STANDARDS COMPLIANCE CE Declaration
The 230V/115 V version of the
The ACUSON X300 PE meets the requirements
0123
ACUSON X300 ultrasound system,
of the Medical Device Directive and carries the PE is provided with a CE marking in
CE Mark. accordance with the regulations stated in Council
Directive 93/42/EEC of June 14, 1993 concerning
Quality Standards
Medical Devices. Siemens Medical Solutions USA,
ISO 9001:2000
Inc., is certified by notified body 0123 to Annex
ISO 13485:2003 / EN ISO 13485:2003
11.3 Full Quality System.
Design Standards
Authorized EC Representative:
UL 60601-1 Siemens Aktiengesellschaft
CSA C22.2 No. 601-1 Medical Solutions
EN 60601-1 and IEC 60601-1 Henkestrasse 127
EN 60601-1-1 and IEC 60601-1-1 D-91052 Erlangen
EN 60601-1-2 and IEC 60601-1-2
Siemens reserves the right to modify the design
EN 60601-2-37 and IEC60601-2-37
and specifications contained herein without prior
Acoustic Output Standards notice.
IEC 61157 (Declaration of Acoustic Power)
Please contact your local Siemens Healthcare Sales
AIUM/NEMA UD-2, 1998 Acoustic Output
Representative for the most current information.
Measurement Standard for Diagnostic
Ultrasound
AIUM/NEMA UD-3, 1998 Standard for Real-Time
Display of Thermal and Mechanical Acoustic
Output Indices on Diagnostic Ultrasound
Equipment
20
3-Scape, ACUSON, AcuNav, Axius,
Clarify, DTI, DTO, ErgoDynamic,
fourSight, microCase, MultiHertz, Native,
QuickSet, SieClear, SieScape, SuppleFlex,
SwiftLink, SynAps, TGO, Velocity Vector
Imaging and X300 are trademarks of
Siemens Medical Solutions USA, Inc.,
and syngo is a trademark of Siemens AG. Contacts
Europe: +49 9131 84-0
SHOWCASE is a registered trademark of Asia Pacific: +65 6341-0990
Trillium Technology, Inc. Latin America: +1-786-845-0697
Headquarters
Siemens Medical Solutions USA, Inc.
51 Valley Stream Parkway
Malvern, PA 19355-1406 USA
Telephone: +1-888-826-9702
www.usa.siemens.com/healthcare
www.siemens.com/healthcare