Beruflich Dokumente
Kultur Dokumente
Technical Data
Anti-Flash Valve
Usage Applications Installation
The HBE Anti-Flash Valve Model AFV Applications which require Anti-Flash The Anti-Flash Valve is a wafer design
is provided specifically to eliminate Valves include boiler feed, condensate, and is installed between flanges of the
damage to the recirculation valve and and certain process fluids which bypass bypass piping size and ANSI rating.
bypass piping from flashing and to a low or negative pressure vessel. Installed adjacent to the return vessel
cavitation. Modulating recirculation valves can the Anti-Flash Valve will assure
run partially open for extended periods protection of the entire bypass system.
How It Works of time during low process demands.
The Anti-Flash Valve functions as a The Anti-Flash Valve provides back
variable orifice to assure the pressure pressure lost from reduced piping
of the downstream liquid does not fall friction and assures a flashing/
below the vapor pressure after exiting cavitation condition does not occur.
the recirculation valve.
Typical Installation
4 Return 4
Vessel
1 1
2 3
AFV-Rev-6/02
Materials of Construction and Dimensions
Pos. Qty. Description Material Dimensions (mm)
01 1 Body A105 Carbon Steel AFV A B
02 1 Guide Bushing 416 Stainless Steel Size In. (mm) In. (mm)
Serrated-Spiral Finish
09 1 Wear Ring Filled PTFE
Both Ends
10 1 Snap Ring 300 Series Stainless
Steel A
11 1 Insert 316 Stainless Steel
06 03 03.1 05 04 11 08
ENGINEERING Inc.
205 Portage Avenue, Three Rivers, MI 49093 USA
Phone: 269-279-2035 Fax: 269-278-6745
HP3M0602