PROJECT NAME:

DONE BY: A.D CHK BY: A.D DATE: 11/10/2016


DRIFT CHECK - DUAL SYSTEM REVISION:
TITLE:
WITH SCBF (X DIRECTION )
ASCE 7-10 CALCULATIONS AND FORMULAS
Table 12.6-1 ELF Permitted Analytical Procedures

Table 12.12-1 Drift limits, for a building assigned to Occupancy Category II, the allowable story drift is ( 0.02 )
=

N.B In this anlaysis the SCBF were removed in the x direction from the model and the seismic forces was scaled down to 25%

Table 12.2-1 Deflection Amplification Factor:Cd= 5.5 DUAL SYSTEMS WITH SPECIAL MOMENT FRAMES CAPABLE OF
Importance factor ,Ie= 1 RESISTING AT LEAST 25% OF PRESCRIBED SEISMIC FORCES
Occupancy category = 1
12.3.4.2 Redundacy Factor = 1.3
Story heigth ,hx= 11.4 ft.

Earthquake Analysis: X-Direction Load combination ~ (2) 1.38D-1.3EQX+ 0.39EQY +0.5L

Maximum Elastic Displacement Computed Under Strength -Level Design Earthquake Forces :
Level 1(in.)
R 0.817 (Deflection in X - Direction - For Storey Level 3)
2 0.613 (Deflection in X - Direction - For Storey Level 2)
1 0.356 (Deflection in X - Direction - For Storey Level 1)
0 0 (Deflection in X - Direction - For Storey Level 0)

Amplified displacement (story level-3) = = 4.49 in. ASCE 7-05 - 12.8.7

Amplified displacement (story level-2) = = 3.37 in. ASCE 7-05 - 12.8.7

Amplified displacement (story level-1) = = 1.96 in. ASCE 7-05 - 12.8.7

0.020
Fig. 12.8-2 Actual story drift for storey level- 3 = = 1.12 in. < .= = 2.10462 in.

0.020
Fig. 12.8-2 Actual story drift for storey level- 2 = = 1.41 in. < .= = 2.10462 in.

0.020
Fig. 12.8-2 Actual story drift for storey level- 1 = = 1.96 in. < .= = 2.10462 in.

SUMMARY:
Level Value Unit Value Unit Results
R 1.122 in. < 2.10462 in. Okay
2 1.414 in. < 2.10462 in. Okay
1 1.958 in. < 2.10462 in. Okay

Location used in drift analysis


PROJECT NAME:

DONE BY: A.D CHK BY: A.D DATE: 11/10/2016


DRIFT CHECK - DUAL SYSTEM REVISION:
TITLE:
WITH SCBF (X DIRECTION )
ASCE 7-10 CALCULATIONS AND FORMULAS
Earthquake Analysis: Y-Direction Load combination ~ (8) 1.38D + 1.3EQY-0.39EQX + 0.5L

Maximum Elastic Displacement Computed Under Strength -Level Design Earthquake Forces :

Table 12.2-1 Deflection Amplification Factor:Cd= 5 Steel special concentrically braced frames
Importance factor ,Ie= 1
Occupancy category = 1

Table 12.12-1 ( 0.02 )


, =

12.3.4.2 Redundacy Factor = 1.3
hx= 11.4 ft.

Maximum Elastic Displacement Computed Under Strength -Level Design Earthquake Forces :
Level 1(in.)
R 0.484 (Deflection in Y - Direction - For Storey Level 3)
2 0.335 (Deflection in Y - Direction - For Storey Level 2)
1 0.158 (Deflection in Y - Direction - For Storey Level 1)
0 0 (Deflection in Y- Direction - For Storey Level 0)

Amplified Displacement (story level 3) = = 2.42 in. ASCE 7-05 - 12.8.7

Amplified Displacement (story level 2) = = 1.68 in. ASCE 7-05 - 12.8.7

Amplified Displacement (story level 1) = = 0.79 in. ASCE 7-05 - 12.8.7

0.020
Fig. 12.8-2 Actual Storey Drift for Storey Level 3 = = 0.75 in. < .= = 2.10462 in.

0.020
Fig. 12.8-2 Actual Storey Drift for Storey Level 2 = = 0.89 in. < .= = 2.10462 in.

0.020
Fig. 12.8-2 Actual Storey Drift for Storey Level 1 = = 0.79 in. < .= = 2.10462 in.

SUMMARY:
Level Value Unit Value Unit Results
R 0.745 in. < 2.10462 in. Okay
2 0.885 in. < 2.10462 in. Okay
1 0.790 in. < 2.10462 in. Okay