Specifications
Current rating: 3A AC, DC max. (AWG #20)
Voltage rating: 250V AC, DC max.
Temperature range: -25C to +85C
(including temperature rise in applying
electrical current)
Contact resistance: Initial value/10m max.
After environmental testing/20m max.
Insulation resistance: 500M min.
Withstanding voltage: 1,500V AC/minute
Applicable wire: AWG #28 to #20
* Compliant with RoHS.
2.5mm pitch grid (dual in raw) wire-to-wire * Refer to "General Instruction and Notice when using
connector that can mate with the socket of Terminals and Connectors" at the end of this catalog.
XAD connector (board-to-wire type). * Contact JST for details.
1 Certified LR20812
Inner type contact lance
Mountable on a variety of panels
Secure lock construction 2 R9851219
Panel layout and Assembly layout
(11.4)
0.1
0.1
0
0
D
C
(25.2)
0.05
8.15
0.1
10.4 0
1
XAD CONNECTOR
Contact
1.9
1.9
6.5
6.6 4.8 2.9
3.1 1.3 1.6
1.3 0.8
2.3
2.4
RoHS compliance
Note: Contact JST for gold-plated products.
XADR-14V
H
Material
15
H
H
JST
RoHS compliance
10
Circuit No.1
identification
21.5
2
XAD CONNECTOR
6.8
identification
XADRP-20V
Circuit No.1
12.0
RoHS compliance