Sie sind auf Seite 1von 5

INSULATION THICKNESS

FIELD JOINT CALCULATOR

Enter steel pipe diameter 168.3 MM

Enter the joint length 400 MM

Enter Insulation Thickness 50 MM

Enter required foam density 50 KG/M3

Required Polyol Quantity 0.34 KGS 0.31 LTR

Required ISO Quantity 0.41 KGS 0.33 LTR

Last updated: October 19, 2012, V 1.1.


The information contained here are subject to change without notice. Please contact- fieldservice@permapipe.ae for the latest version.
PIPE DIA
PIPE DIA WITH INSULATION

JOINT LENGHT
STEEL PIPE DIAMETERE
INCH MM INCH
0.5 21.3 22
0.75 26.7 24
1 33.4 26
1.25 42.2 28
1.5 48.3 30
2 60.3 32
2.5 76 34
3 88.9 36
4 114 38
5 141.3 40
6 168.3 42
8 219.1 44
10 273.1 46
12 323.9 48
14 355.6 56
16 406.4 60
18 457.2 72
20 508 80
ERE
MM
558.8
609.6
660.4
711.2
762
812.8
863.6
914.4
965.2
1016
1066.8
1117.6
1168.4
1219.2
1422.4
1524
1828.8
2032

Das könnte Ihnen auch gefallen