Application
RunnTech P9000 Proportional Amplifier, is mainly used in Hydraulic Proportional Valves.
Technical Information
Environment Parameter
Storage temperature -40+80
Operating Temperature -20+50
Mechanical Parameter
Weight 85g
Electrical Parameter
Power Supply Voltage 2032VDC
Ripple Factor 10%
Output Voltage UA UB-1.5V DC, Pulse-width modulation
Output Current 1A, Max 2.4A, anti-short Max 1.5A
Adjustment Range Imax: 0 ~ 1.6A, Imax: Imax+(0 ~2.4A), default: Imin=0A, Imax=1A
No-load Current Max: 20mA
Output Voltage Unom, 0 5V DC, 0 10V DC, or 0 -15V DC, default: 0 -5V
Reference Voltage 10VDC4%, max load 5mA
Input Resistance >200K
Potentiometer Setting Value 5K 10K
Ramp Time (Up & Down) 0.1 10s, default: 0.1s
Flutter Frequency 60Hz or 120Hz, default: 60Hz
Flutter Frequency Value 0 750mA
Load Resistance 12K24K
Tel: +86 519 8223 0053 | Fax: +86 519 8886 5269 | E-mail: info@runntech.com | Website: www.runntech.com 1-3
RunnTech Electronics (Changzhou) Corp. P9000 Proportional Amplifier
Product Configuration
P9000 - 2S
Single channel no need to indicate
Serial Number Dual channels: 2S
Single Channel Dual Channel
B PHase A Phase
Electromaget
1
2 B
B1
2 3 4 5 6 7 8 9 10 11 12 13 14
3 0V Anlog input
A2
4 10V 0-10V
A1
5 IN
6 9V
External setting -9V
External setting
device signal input
7 M0 device signal input
M0 GND
9 V-
External power supply IN
11 V+
9V
12 GND
13 K1 Slope of short
14 K0 circuit
0V
MIN current adjustment External power supply
Potentiometer
24V
MAX current adjustment
RIS rise time adjustment
MIN
FAL fall time adjustment current adjustment
Potentiometer
MAX
current adjustment
B Phase
A Phase
RIS
rise time adjustment
FAL
fall time adjustment
Tel: +86 519 8223 0053 | Fax: +86 519 8886 5269 | E-mail: info@runntech.com | Website: www.runntech.com 2-3
RunnTech Electronics (Changzhou) Corp. P9000 Proportional Amplifier
Product Installation
Tel: +86 519 8223 0053 | Fax: +86 519 8886 5269 | E-mail: info@runntech.com | Website: www.runntech.com 3-3