Beruflich Dokumente
Kultur Dokumente
com
ISSN: 2394-2630
Research Article CODEN(USA): JSERBR
Electronic Monitoring System for Hydrogen Produced from the Oxidation of Human
Urine (Mhydros)
52
Lozada-Castro JJ et al Journal of Scientific and Engineering Research, 2017, 4(2):52-57
A special property of hydrogen is its thermal conductivity being 0.187W/mK at normal temperature and
pressure is significantly higher compared to other gases, this property is used to design specific sensors for this
gas.
In this work, an electronic system was designed, assembled and implemented to monitor online and in real time
the percentage of hydrogen produced by a reactor that oxidizes the human urine and uses the electrons obtained
to produce hydrogen in chemical equilibrium, the system measures the percentage Of hydrogen using an HPS-
AMS-100 sensor, the gas flow produced by the reactor and the required current by the reactor.
53
Lozada-Castro JJ et al Journal of Scientific and Engineering Research, 2017, 4(2):52-57
54
Lozada-Castro JJ et al Journal of Scientific and Engineering Research, 2017, 4(2):52-57
adjusted by measuring the pressure and local temperature through BMP180 sensor modules communicate with
the Arduino board via the I2C protocol, common connections SDA and SLC and are energized by the 3.3V and
GND pin card.
Current measurement
The ACS712-20A module connected via 3-wire DC, SIGNAL and GND, connected to the analog input of the
Arduino Uno digital card, this module is connected in series with the electrolytic cell, which conducts current
through an internal integrated route, containing a sensitive sensor magnetic field produced by the current
according to Figure 3.
55
Lozada-Castro JJ et al Journal of Scientific and Engineering Research, 2017, 4(2):52-57
The application developed automatically generated a comma separated file backup for each measurement
containing the following values: time, concentration, flow and current.
The hydrogen concentration value had an uncertainty of 0.5% which matches the manufacturer's specifications
manual. an error of 2% measured flow due to the resolution of the adc and calculation from the differential
pressure was obtained has an uncertainty of current 0.05A due to the resolution of the arduino card,
experimentally verified using introduced a flow meter and a digital multimeter, is I can improve range of flow
measurement by changing the measurement principle because the output streams generated at the cathode are
small, the software allowed us to visualize in real time the changes made in the electrochemical cell, allowing
optimization hydrogen generation.
Conclusions
The system enabled to monitor MHYDROS the hydrogen produced by the MIOIL reactor and found to using
urea dissolved in the anode and cathode water percentages of 45% hydrogen, flows de13.5cm3 / min and with
an applied current of 2A were detected with variations of 2% indicating that the system works reliably and
robustly, allowing determine define variables associated with the efficiency of the electrochemical process.
Acknowledgment
The authors thank to the University of Nario, VIPRI Research System.
56
Lozada-Castro JJ et al Journal of Scientific and Engineering Research, 2017, 4(2):52-57
References
[1]. Dinga Gustov P. Hidrogen. The ultimate fuel and energy carrier. En: Int J. Hydrogen Energy.
Vol.14,No.11, pp777-784. 1989.
[2]. Informe Final "Desarrollo nuevos prototipos en fuentes no convencionales de energa". Grupo Energa
Alternativa, Universidad de Antioquia. 1997
[3]. Mundo Electrnico Colombiano. Octubre-diciembre. 1999
[4]. Informe Final "Desarrollo prototipos y Evaluacin plantas piloto". Grupo Energa Alternativa,
Universidad de Antioquia. 1998.
[5]. Cuidoelagua.org. Qu son las Aguas Residuales?, disponible en:
[http://www.cuidoelagua.org/empapate/aguaresiduales/aguasresiduales.html].
[6]. Contaminacin Agrcola de los recursos hdricos, Depsito de documentos de la FAO, disponible en:
[http://www.fao.org/docrep/w2598s/w2598s03.htm#TopOfPage].
[7]. Enfermedades por contaminacin, Profesor en lnea, disponible en:
[http://www.profesorenlinea.cl/ecologiaambiente/Contaminacion_Enfermedades.htm].
[8]. Castells Xavier, Jurado Lorena, El hidrogeno y las pilas de combustible, Madrid: Ediciones Daz de
Santos, 2012.
[9]. AMS, HPS-100 Datasheet AMS, Unterpremstaetten, 2016.
[10]. Allegro MicroSystems, Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 2.1 kVRMS
Isolation and a Low-Resistance Current Conductor Allegro MicroSystems, 2013.
[11]. Honeywell Inc, AWM42150VH, Honeywell Inc, Morristown , 2016
[12]. Honeywell, Installation Instructions for the AWM40000 Series Mass Gas-Flow Sensors, Honeywell,
Freeport - Illinois, 2005.
[13]. Honeywell, Mass AirFlow Sensor, Honeywell Sensing, 2015.
[14]. Honeywell, Mass Flow Sensors: Mass Flow versus Volumetric Flow and Flow Rate Unit
Conversions, Honeywell Inc, Golden Valley, 2012.
[15]. Honeywell, Gas Media Compatibility and Correction Factors, Honeywell Inc, Golden Valley, 2012.
[16]. Bosch Sensortec, BMP180 Digital pressure sensor, Bosch Sensortec, Reutlingen, 2013.
57