Frick Motor Plus Advantage

The FRICK MOTORPLUS PACKAGE is an integrated motor/starter combination


designed specifically for use with FRICK refrigeration screw compressors.
The package incorporates a number of features not found in commercially aailable motor starter packages.
These features provide outstanding value, efficiency, and reliability through the use of correctly matched qual
ity components, stateoftheart electronic protection devices, and all the required compressor interfaces.
A summary of the many exclusive benefits is given below:

SINGLE SOURCE RESPONSIBILITY - Determination OIL PUMP MOTOR STARTER A threephase starter for
of responsibility following a malfunction of the motor the compressor oil pump motor is supplied with separate
and/or the starter is eliminated since Johnson Controls- fuses to provide protection against thermal overload and
FRICK supplies the complete MOTOR PLUS PACKAGE with short circuit (Optional).
the motor mounted. One purchase order eliminates the
confusion of responsibility by coordinating motor and starter CURRENT TRANSFORMER In addition to current
specifications. transformers used with the motor overload protection, an
independent current transformer is supplied to signal the
MOTOR OVERLOAD PROTECTION The electronic compressor microprocessor (or ammeter/load limiter in
overload provided in the motor/starter package is an the case of electromechanical controls) when the motor
adjustable microprocessor-based device which is factory exceeds preset load limits.
set to the optimum protection levels of each motor. Last
trip indications provide easy operator control, and fault MAIN DISCONNECT CIRCUIT BREAKER The door-
history storage provides valuable maintenance information. interlocked circuit breaker operator has provisions for
padlocking in the off position.
SINGLEPHASE PROTECTION The electronic overload
prevents the motor from starting or running with a single- WIRING AND TERMINAL IDENTIFICATION All wiring
phase condition (electromechanical starter only). is stranded copper conductor, color coded and bundled.
Power circuits are a minimum of 12AWG and control circuits
LOW VOLTAGE AND PHASE REVERSAL PROTECTION within the panel are 14AWG. Motor wiring is factory matched
The module provides protection in the event of low or to the requirements of the motor. Control conductors are
unbalanced voltage, and will prevent starting if phases are identified at each end and color coded to interface with
reversed (electromechanical starter only). those of the screw compressor unit, which facilitates field
identification and service.
SHORT-CIRCUIT PROTECTION Thermal-magnetic
circuit breakers are supplied as standard to provide short- CSA AND UL LISTED Both starters and motors are
circuit protection. In addition, all circuit breakers above 250 listed with the Canadian Standards Association for use
amps have adjustable electronic trip units. in appropriate applications throughout North America.
In addition, the starters are listed with the Underwriters
HIGH QUALITY CONTACTORS Built to AC3 life Laboratory.
cycle specifications, the horsepower-rated contactors are
available in full-voltage (ATL), wye-delta closed transition 1.15 MOTOR SERVICE FACTOR All motors supplied
(YD), and solid-state bypass (SS) configurations. as part of the standard MOTOR PLUS PACKAGE are
conservatively designed to give normal NEMA life
OVERSIZED CONTROL CIRCUIT TRANSFORMER expectancy even when operating continuously up to 15%
The control circuit transformer is individually fused to over nameplate horsepower.
provide singlephase power for the compressor controls
and oil heaters.
Frick Motor Plus Advantage

IMPROVED INSULATION SYSTEM Class F INDIVIDUAL MOTOR TESTING Each motor is submitted
insulation is standard on all motors, providing maximum to a battery of performance tests to assure compliance with
protection against corrosion, abrasion, moisture, and high the manufacturers rigid quality control standards.
temperatures. Maximum temperature rise will not exceed
80C at 1.0 service factor operation. UNPRECEDENTED 24 MONTH WARRANTY - The
FRICK MOTORPLUS PACKAGE comes with a generous
SUPERIOR TORQUE CHARACTERISTICS All motors two-year warranty covering the compressor motor and
have a minimum 100% pullup torque to accelerate starter (see Form MPPW88 for full details). The warranty
compressor load on reduced voltage starting. covers the following:

DYNAMICALLY BALANCED ROTOR All rotors are Motor failure caused by severe overload
dynamically balanced beyond commercial limits to a Motor failure caused by single-phase condition
maximum of 0.0006 peak to peak displacement to minimize
Motor failure caused by improper connection
system vibration.
Motor bearing failure caused by inadequate lubrication
OVERSIZED ANTIFRICTION BEARINGS Ball bearings Motor bearing failure caused by improper alignment
are designed for long life and quiet operation using C3 fit
tolerances. Land Freight Charges for replacement motors, starters,
or repair parts
RUGGED CAST IRON CONSTRUCTION High grade Authorized field repairs for motor and starter
cast iron frames and end brackets are machined to close
tolerances to ensure accurate alignment and fit. Pickup and delivery of repaired motors
Authorized diagnostic checks
Vacuum Pressure Impregnation (VPI) - Process
draws a vacuum on the motor stator when submerged in The following items are NOT covered under warranty:
varnish to fill all the wire separation voids. Air Freight Charges
SPACE HEATERS - All motors contain a low-watt-density Failure due to lightning, fire, flood, or sabotage
space heater to prevent moisture formation in the windings Consequential damages or loss of production
caused by increased ventilation requirements in engine Equipment removal and replacement costs
rooms during the off cycle.

PAINTED ROTORS - Painting of the rotors prevents


aluminum oxide formation which break off and are thrown
against the stator, piercing the wires.

Form 100.100-ADV04 (2011-12) JOHNSON CONTROLS


Supersedes: E100-300 ADV (1997-05) 100 CV Avenue
Subject to change without notice Waynesboro, PA 17268 USA
Published in USA PDF Phone: 717-762-2121 Fax: 717-762-8624
2013 Johnson Controls, Inc. ALL RIGHTS RESERVED www.jci.com/frick