THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N. 11'H STREET.

LAs VEGAS, NV 89101-3611

This Request for Quole number' he following:


Rehabilitation and Energy Upgrades @ 7 Nordic Lights Dr.. Las e NV
Ighborhood Stabilization Program (NS

l\ ~G r _\;( QUOTE FORM


.(,J \ S {GJ-
y ~XV~U\ Scope of Work
V 7136 Nordic Lights Dr., Las Vegas,

Work listed below shall meet the following standards: ffJ~1-~t


1. Home Performance Standards for Warm Climates (HPSFWC)
2. Clark County Optional Specifications for Water Saving Measures. October 2009 (WSM)
3. Clark County Housing Rehabilitation Specification Manual
,Cfq 1-.J
4. Southern Nevada Regional Housing Authority specifications
5. Standard Materials/Appliance List included in this Work Scope ~vl \16'
6. Other requirements specifically listed in this Work Scope (incl. Installation Notes)
7. Local building codes and amendments for new or substantially altered work
8. Saturn Mechanical Systems Field Guide. Chapter 6 (2006)
9. NSP Rental Project Standards Draft 5/25/2010
10. Guidelines for Complying with BPI's Technical Standards for the Air Conditioning and Heat Pump
Professional
11. When the above documents contain multiple or conflicting requirements, the most stringent shall apply
12.
L :scop~OF v.;ORK ':,NO QUOtE FORM ...._~ __~ .J
ITEM DETAilS AMOUNT
I Health, Safety & Building Code M~a8ure8 .....,.

General
Inslall 20 min. fire-rated solid core door and frame to garage wilh self-closer
Inslall one CO Detector per fioor meeling UL-2034, per manufacturer's instructions
-- - - -
Remove unpermitted/unsound patio cover, properly demo related electrical. patch
disturbed building finish to match adjacent
Remove unpermitted/unsound balcony/deck, properiy demo related eleclrical, patch
disturbed building finish to match adjacent
- ------,-,---".,"---_.,--"
ReconnecVreplace dryer vent, ensure functional backdraft damper
_.- - -
Repair mesh on screened vents
Open blocked screen vents in garage
--- "-
Install concrete door landing to meet residential building code
- --
Provide mechanical venlilation per ASH RAE 62.2 based on all installed building shell Install 2 Panasonic
sealing and energy efficiency measures (use R-B insulaled duct) i energy recovery
ventilators - one in
living room ceiling
3 I-17~ I')

near back, one in


upstairs hall ceiling

Replace banisterfbalustrade with code-compliant type Return to wall

Replace glass with safety glass


Replace broken glass
Inslall bedroom egress window

Water Heater
Center draft diverter over flue and secure
InstalUrepair 2 seismic straps, secure to studs
Insulate exposed hot and cold water piping with foam pipe insulalion (use noncombuslible
fiberglass within 6" of flue)
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY • 340 N 11ro'STREET • LAs VEGAS, NV 89101*3611
This Request for Quale number is Q10073 for the following:
Rehabilitation and Energy Upgrades @ 7136 Nordic Lights Dr., Las Vegas, NV
SNf\HA
Neighborhood Stabilization Program (NSP)
QUOTE FORM

combustible materials
Page 2 of 8

Repairlinstall double wall flue through building cavity, maintain 1" clearance to d~

Repair flue, ensure flue is continuous, proper support and clearances <
~o ~
and,D(\l~"O~
~~~
*
'('-
r"Pc:orrect slope and
clearance to drywall

Electrical Panel

Legibly label all breakers in panel to cleariy indicate area served

install inside metal plate on AlC electrical panel 1(11'-£ v.J VI S(oN'N£ (,7 !tfo/(.~t-D ,P-
Replace two 220 breakers, not listed for panel.

Electrical Receptacles/Switches
Remove unsafe/unpermitted receptacles and wiring, properly demo and cap wires Includes 220V circuit
to rear patio routed
through face plale of
main panel- remove
breaker & blank off to
provide 2 spares
Inslall GFCI receptacles in bath, kitchen
Bring electrical wiring to code in garage (e.g. properly secure wires, replace j*box with
code compliant box)
Inslal120 amp receptacle on individual circuit with a single outlet (dryer-laundry) dishwasher, garbage
disposal,
washer/dryer, range
hood,
Replace damaged switches/receptacles
Install bedroom branch circuits with protected arc-fault breakers.
Install GFCI at all exterior outlets, including overhead, and any receplacle outlel on the provide at roof AlC
roof or within 25 feel of AlC equipment.
Supply all 15 and 20 amp branch receptacles in wet locations with bubble type covers.
Install GFCI receptacles all locations at or beneath kitchen counlers.

Plumbing
Allowance for repair of water leaks
Install screw-on backflow preventers on hose bibbs 2 hose bibbs
Install main water shut-off not in contact with soil, with operating access
Install dishwasher air gap a minimum of 1" above flood level rim of kitchen sink
Replace inoperable or broken fixtures
Install pressure vacuum breaker a min. of 12" above all downstream piping
Remove water softener
Install 2 seismic straps to code on water heater
Ensure gas valves are properly capped or plugged.
T&P terminated minimum 6", maximum 24" above grade, pointed downwards. Needs to be
corrected,
Connect laundry sink to drain properly into adjacent laundry waste room line Garage
Provide and install new kitchen sink with same size, Provide and install new single lever
faucet.
THE SOUTHERN NEVAOA REGIONAL HOUSING AUTHORITY. 340 N. 11~ STREET. LAS VEGAS, NV 89101.3611

This Request for Quote number is 010073 for the followIng


Rehabilitalion and Energy Upgrades@ 7136 Nordic Lights Dr., Las Vegas, NV

Neighborhood Stabilizalion Program (NSP)


QUOTE FORM
Page 3 of 8
Provide and inslall new kilchen garbage disposal

Total Health, Safely & BUildIng Code Measures

Energy Efflclsncy Measures


Infiltration

Reduce air leakage of the building shell to 1000 CFM50

Insulate and air seal rim joist between fioors with R-13 spray foam
-------~'JIr",. <.1 (;0
Seal air leaks at door jamb strike plates

Seal air leaks at window frames g '1.:t,6" t.-A-Tu(L


.:Trl<.l,..l/Dc\)
Glue R-38 insulatIon to top of attic access panel, weatherstrip perimeter of opening (or
replace hatch
opening 10 holdwith Insulated premanufactured
insulation unit), add 2x baffles if not present around .r"" l.-\J~ll

Doors

Replace front wood door and frame with insulated metal panel dOOr (R.6.5 or grealer)
Weatherstrip doors
Replace/add door sweep

Windows (sq tI)

Install dual glazed low-E/viny/lcomposite windows (U=0.30/SHGC=0.30) or belter


Install window film per HPSFWC 3.1.2
all windows

Color
Install solar screens per HPSFWC 3.1.1, fiush mount, 0.20 shading coefficient, brown

Remove three arch top windows and infill wall, patch stucco and paint

1sl fir bedroom,


dining room, 2nd
bedroom upstairs
Mechanical, HVAC & Insulalion

Replace existing rooftop package gas furnace/electric AlC. Install properly sized 80.
AFUE gas furnace, 15 SEER AlC. Provide SUPPorting load cales based on all energy
efficiency measures to be installed in home Size equipment for
retrofil energy
f'" f'iN ~ IS, \) .; 12-0 0 efficiency measures.
Proposed size 60k
5et ~
4.
1I
0. (> 0
Btu healing, 3 ton
Replace existing rooftop package furnace/AC. Inslall properly sized 80. AFUE gas COoling.
furnace, in
inslalled home SUPPorting load cales based on all energy efficiency
provide measures to be

nne in tal
Insulate rooftop plenum with R8 duct wrap.
-L---o
-r~(.(.,VOW
Seal duct air leakage to 6% CFM25, leakage to outside.
~
Install new duct system with optimized design
floor of attic to be buried in aWe insulation
- minimize duct length, configure ducts at
..rf"/C Ll/bkO

?-400
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N. 11'''' STREET. LAs VEGAS, NV 89101-3611

This Request for Quote number is 010073 for the following:


Rehabilitation and Energy Upgrades@ 7136 Nordic Lights Dr.. Las Vegas. NV
Neighborhood Stabilization Program (NSP)
QUOTE FORM
Page 4 of8

HVAC engineering calcuiation: Manual J, D and S (incorporating all installed energy By licensed Mech.
efficiency measures and final building shell leakage) Eng.
Install and program thermostat
Insulate ducts to R-30 by burying all ducts possible in 8" (min) of biown cellulose, use R-8 R-30 min
duct wrap on exposed ducts 16"1 ~ t-f!. \lL-~"(L..s
Mechanical ventilation: use 4" R.8 insulated duct
Vent exhaust fan to outside
Increase attic insulation, provide blown fiberglass R.54 min.
Insulate/air seal frame floor cavity over garage with impermeable spray foam. R-30 min.

Install slab perimeter insulalion. V ~ .fin ~ \; ~ -t+.


Replace water heater, Mfr: AD Smith Eftex 40 gal ... 70 EF min.
Replace fireplace insert with new sealed combustion direct vent fireplace insert.
Replace kneewall batt insulation where missing - install air barrier/RoB duct wrap air seal all kneewalls

Lighting
Replace all incandescent light bulbs with compact fluorescent bulbs. Use appropriate
bulb style for fixture (e.g. flame, globe, floodlight) (Install T8 at tube type)
Provide interior light fixtures Bathrooms,
bedrooms
Inslall motion sensors in bathrooms, laundry and pantry to control lighting.

Water
Install low-flow faucet aerators (2.0 gpm kitchen, 1.5 gpm bathroom sinks)
Install low-flow EPA WaterSense approved toilets (1.28 gpf max.) 3 toilets
Install low-flow EPA WaterSense approved shower heads (2.2 gpm max.)

Renewable Energy
Install photovoltaic system
Install solar hot water system

Tolal Energy Efficiency Me•• ure.

Interior finishes
Repair interior wall and ceiling finishes and paint all interior wall, ceiling and paintable trim
Replace existing countertop with laminate countertop $
Repair existing countertop $
Repair/replace flooring $
Repair/replace sliding accordion door $
Repair/replace bath vanity $
Install tile flooring, remove existing flooring all bathrooms, $
laundry and all first
floor common areas
Install new interior window coverings $
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N, 11f" STREET. LAS VEGAS. NV 89101-3611

This Request for Quote number is Q10073 for the following


Rehabilitation and Energy Upgrades @ 7136 Nordic Lights Dr., Las Vegas, NV
Neighborhood Stabilization Program (NSP)
QUOTE FORM
Page 5 of 8

Repair interior doors laundry, closet $


Replace interior doors $
Remove cabinet base and upper cabinellhat was added by homeowner. Palch repair, $
paint drywall to match adjacent wall.
Replace missing bath accessories $
Replace cabinets kitchen, bathroom $
Repair/replace cover to kitchen light fixture $

Landscape
Site
Remove existing trees
Remove existing shrubs
Install new Iront yard landscape per WSM
Repair existing irrigation per WSM
Install new irrigation per WSM
Paintlrellis
Remove trellis
Paving
Install drainage block north enclosure waH
Fencing/walls

Check existing irrigation, repair and inst~1lnew if needed to comply with WSM
Remove and cap gas line in backyard.

Electrical

Remove interior surface conduit and fish replacement wiring through wall
Properly run and secure phone/cable TV wire runs

a
Provide and install new ENERGY STAR dishwasher
Provide and Install new ENERGY STAR refrigerator
Provide and instal! new oven/range
Provide and install new cooktop
Replace ceiling fans with ENERGY STAR model and provide new ENERGY STAR ceiling
fans

Install new kitchen exhaust fan and vent to outside with backdraft damper, repair all
finishes to match adjacent.
Provide and install new garbage disposal

Exterior

Repair damaged stucco to match existing texture, patch holes. Paint all exterior building
surfaces
Repair damaged fascia
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY • 340 N. 11'" STREET. LAS VEGAS, NV 89101.3611

This Request for Quote number is Ql0073 for the following


Rehabilitation and Energy Upgrades@ 7136 Nordic Lights Dr" Las Vegas, NV

NeighborhOOd Stabilization Program (NSP)


QUOTE FORM
Page 6 of 8
Repair exterior utility boxes to ensure weatherproof closure

Seal all outdoor light fixlures to wall, Leave bottom of fixture unsealed

Garage

Repair concrete slab

Repair garage door opener for proper operation


Clean garage floor

Provide new screened and louvered vent openings

Repair wall and ceiling holes to main lain 1-hour enclosure


Replace allic halChnadder with 1-hour rated hatch

Tesllng/MIsc.

Perform blower door test per attached Testing Schedule and provide wrillen report
Perform duel leakage for all HVAC syslems test alter Work is compleled and duct sealing
specjfjcalions have been mel and provide wrilten report 1~5
Test and calibrate all systems for proper operation per Cades, manufacturer's
specifications and HPSWFC Ch. 5, provide written report of items tested and results.
11.5
Adjust equipment 10comply with operational slandards

Tesl combustion equipmenl and adjusVrepair as needed (per BPI Performance /6)
Specifications and HPSFWC Ch. 6), provide written report of items lesled and results
• Subcontracted Professionals:
IZ,
• Structural Engineer (as applicable", not included in above work) $
• Mechanical Engineer (as applicable/if nol included in above work) $

• Certified Energy Consultant (as applicablelif not included in above work) 'P~I'-C-'D A~oV\:..
Total Testing/Subcontracted Profess/anal
Other Cosls
j)t<. \e.-t:o fimO\/€.
Permit

Dumpster/RecYCling

---
TOTAL CONTRACTOR COSTS of ALL MEASURES
1
1 j
I

Contractor Profit/ Overhead / Other

Add Totat CONTRACTOR COSTS of All Measures

Total $
Contract Bid
Amount
Written amounl

Signature
Printed Name
Date