GENERAL NOTES ELECTRICAL/ELV(BACK BOX ) SIZE EQUAL TAG QTY

VOID INCLINED TOWER LEVEL UNITA - BLOCK WALL SECTION 1. ALL DIMENSIONS ARE IN mm
LIVING/DINING/BED ROOMS /KITCHEN/COMMON CORRIDOR

v n 2.ALL HEIGHTS ARE FROM F.F.L


2 MODULE BOX 76.5 x 76.5 x 51 2M1

3 MODULE BOX 76.5 x 99.7 x 51 3M1


p p 4 MODULE BOX 76.5 x 136.8 x 51 4M1

o WINDOWS DETAILS 6 MODULE BOX

SHAVER
76.5 x 214.2 x 51 6M1

Z
135.5 x 76.5 x 51
TO BE GIVEN
SINGLE BOX 76.5 x 76.5 x 51 X

o o DOUBLE BOX 76.5 x 136.5 x 51 Y

YARD/ MAIDS ROOM

SINGLE BOX 76.5 x 76.5 x 51 X


h i v DOUBLE BOX 76.5 x 136.5 x 51 Y

l n HOME AUTOMATION(BACK BOX )

2 MODULE BOX 76.5 x 76.5 x 51 2M


(2M1) (X)
Y u (2M1) (2M1)
4 MODULE BOX 76.5 x 136.8 x 51 4M

1 6 MODULE BOX 76.5 x 214.2 x 51 6M

25 S3
MASTER BATHROOM
YARD s
FFL+ 23425
FFL+ 23425 Y ALTAIR
Indocean Developers (Pvt) Ltd
SSL+23375 No: 121A, Sir James Peiris Mawatha
SSL+23375 Colombo 02
Approved
e WM e Approved as Corrected
Submit Specified Item
f g S3 WH
Revise and Resubmit
Rejected
25

25
The review is only for general conformance
KITCHEN SSL+23250 with the design concept of the project and
S4 FFL+ 23450 SECTION- d SECTION- p
general compliance with the information given
SSL+23400 FFL+ 23450 SECTION- a SECTION- c in the Contract Documents. Contractor is
responsible for: Dimensions to be confirmed
d 25 S5 d RG2 SSL+23400 FFL+ 23450 BALCONY and correlated at the job site; information that
pertains solely to the fabrication processes or
MAID'D ROOM POWDER LIVING to the means, methods, techniques,
SSL+23375 FFL+ 23450 FFL+ 23425 sequences, and the procedures of
constructions; coordination of the Work of all
FFL+ 23425 SSL+23400 SSL+23375 trades; and for performing all work in a safe

MAID'D W.C. REF and satisfactory manner.


Any approval from the Engineer/Consultant of
submittals, materials and workmanship etc.
x S2 S1 shall not relieve the Contractor of his sole

25
x RG1
responsibility and obligation to comply with
all requirements under the Contract.

g (JB) (JB)
a a i v (JB) Consultant/Engineer
u Reviewer
VDP

w Signature Date

(2M) (4M) (4M)

t t
m
q r
b b
h
BATHROOM3
FFL+ 23425
SSL+23375 25 REFERENCE DRAWINGS
k SECTION- b REV. REV.
DESIGN DRAWING NO SHOP DRAWING NO
NO NO
SSL+23400 ATR-DT3-AR-DWG-2012-01 R1 ATR-SPLL(MAX)-EL-DWG-GN-TYP-5001 R1
j FFL+ 23450 ATR-DT3-AR-DWG-2015-01 ATR-SPLL-AR-DWG-IT-L8-0131 R2
R0
BEDROOM2 DINING ATR-SPLL-(JSSL)-SS-DWG-IT-L8-0013
BEDROOM 3 ATR-DT3-AR-DWG-2020-01 R0 R1
FFL+ 23450
FFL+ 23450 ATR-DT3-AT-DWG-2023-01 R0 ATR-SPLL(MAX)-GM-DWG-IT-L30-3588 R0
MASTER BEDROOM SSL+23400
SSL+23400 ATR-DT3-AR-DWG-3560 R3 ATR-SPLL(MAX)-EL-DWG-IT-L20-1117 R1
FFL+ 23450 c c
ATR-DT3-AR-DWG-3561 R3
SSL+23400
ATR-DT3-AR-DWG-3513 R0
ATR-PE-ST-DWG-0111 R5

PROJECT
BATHROOM2
25 FFL+ 23425 (X)
COLOMBO
COLOMBO, SRI LANKA
RESIDENTIAL TOWER
SSL+23375 (X)
(X) (Z)
(x) (x)
(X)
CLIENT
INDOCEAN DEVELOPERS (PVT) LIMITED
(x)

l f q j k m r s w DESIGN ARCHITECT
SAFDIE ARCHITECTS, LLC.
100 PROPERZIE WAY
SOMERVILLE, MA 02143-3740 USA
SECTION- e T 617.629.2100 F 617.629.2406
SECTION- v
ASSOCIATE ARCHITECT
DESIGN TEAM 3
SINGAPORE
T 658.499.7168

CM
STRUCTURAL ENGINEER
MR. PREDRAG EROR
P.O. BOX 102803, DUBAI, UAE
T 9714.3629234 F 9174.3629234

(JB)
MECH, ELECT, PLUMBING ENGINEER
(JB) CKR CONSULTING ENGINEERS PVT. LTD.
(X) PO BOX 73889
(JB)
DUBAI, UAE
(X)
T +97143384277
(2M1)
(Z) (Y)
(6M) (X) (X) (Y) (X) (X) (X) (Z) LANDSCAPE ARCHITECT
(X) P LANDSCALE CO., LTD.
59/3 SOI SUKHUMVIT 39 SUKHUMVIT ROAD, KLONGTON NUA
WATTANA, BANGKOK 10110 T. 662.261.3700.9
(X) (2M)
(2M1) (2M1) (6M1)
(X)
(6M1) LOCAL STRUCTURAL ENGINEER & SUPERVISION CONSULTANT
(6M1) (4M1) (4M1)
DEEPAL WICKREMASINGHE ASSOCIATES
(X)
NO. 377/2, Thalawathugoda Road, Hokandara South, Sri Lanka.
T- +94 11 4402395

ISSUE
SECTION- f SECTION- g SECTION- h SECTION- i SECTION- j
SECTION- k SECTION- q
NO. DESCRIPTION DATE
SECTION- x
00 FOR APPROVAL 11.01.2017
01
TRUNKING
100mm x 60mm TRAY 100mm x 60mm
50mm x 50mm
(FOR ELV)
CO-0RDINATION CERTIFICATE
(FFL+2900mm) TRAY 2nos
(FFL+2900mm) S. NO DISCIPLINE DATE SIGNATURE
2nos
1.
AUTOMATION DB 5nos AUTOMATION DB
SLOTTED CHANNEL 100mm x 60mm
2.
(X) 100mm x 50mm
TRUNKING VERTICAL TRAY
(FOR ELV)
KEY PLAN
(JB) (FOR ELECTRICAL)
(JB) PIPE 150mm x 60mm
VERTICAL TRAY
(FOR ELECTRICAL) H F D B
(2M1)

(4M) (2M)
DISTRIBUTION BOARD
DISTRIBUTION BOARD
G E C A

(2M)
(2M1) (6M1)
(2M1)
(4M1)
(4M1)
(2M1) (6M1) (2M1)
Main Contractor

SECTION- l SECTION- m SECTION- t SECTION- n


SECTION- O
Sub Contractor
INCLINED TOWER - UNIT A - SHEAR WALL SECTION MAXAIRE (PVT) LTD
110 , Isipathana Mawatha,
Colombo 05.
T : +94 11 2501370, 2501305, 4641477
Level 9 F : +094 11 2589860
E : info@maxaire.net

CM CM CM DISCIPLINE ELECTRICAL
WALL MOUNTED LIGHT CM
DRAWING TITLE
FIN.CEILING = L+2400MM
INCLINED TOWER UNIT A
LEVEL 8,10,12,14,16,18,20
WALL SECTION
Detailed Drawn Checked Approved Scale Size
(X)
(X) (4M)
(4M)
(6M)
(X)
1:100
(Z)
Udayashantha Hirushan Fazal Jayasuriya A1
Date Date Date Date
(2M1)
(2M) 11.01.2017 11.01.2017 11.01.2017 11.01.2017
(2M1) (6M1) (6M1) (X)
(x)
(2M1)
(4M1)
(6M1) Drawing Number Rev.
(4M1)
ATR-SPLL(MAX)-GM-DWG-IT-(L8-L20)-6003 1
Status
SECTION- Y SECTION- r SECTION- s SECTION- u SECTION- w SHOP DRAWING