Sie sind auf Seite 1von 47

MP2800 Series Router Install

Manual

V1.2

Maipu Communication Technology Co., Ltd


No. 16, Jiuxing Avenue
Hi-Tech Park
Chengdu, Sichuan Province
P. R. China
610041
Tel: (86) 28-85148850, 85148041
Fax: (86) 28-85148948, 85148139
URL: http:// www.maipu.com
Mail: overseas@maipu.com

Maipu Confidential & Proprietary Information Page 1 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

All rights reserved. Printed in the Peoples Republic of China.

No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any
language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual
or otherwise without the prior written consent of Maipu Communication Technology Co., Ltd.

Maipu makes no representations or warranties with respect to this document contents and specifically disclaims any implied
warranties of merchantability or fitness for any specific purpose. Further, Maipu reserves the right to revise this document
and to make changes from time to time in its content without being obligated to notify any person of such revisions or
changes.

Maipu values and appreciates comments you may have concerning our products or this document. Please address comments
to:

Maipu Communication Technology Co., Ltd


No. 16, JiuXing Avenue, Hi-Tech Park
Chengdu, Sichuan Province
P. R. China
610041
Tel: (86) 28-85148850, 85148041
Fax: (86) 28-85148948, 85148139
URL: http:// www.maipu.com
Mail: overseas@maipu.com

All other products or services mentioned herein may be registered trademarks, trademarks, or service marks of their
respective manufacturers, companies, or organizations.

Maipu Confidential & Proprietary Information Page 2 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


(
MP2800 Series Router Install Manual V1.2

Maipu Feedback Form


Your opinion helps us improve the quality of our product documentation
and offer better services. Please fax your comments and suggestions to
(86) 28-85148948, 85148139 or email to overseas@maipu.com.

Document Title MP2800 Series Router Install Manual V1.2


Product Document 1.2
Version Revision
Number
Evaluate this Presentation:
document (Introductions, procedures, illustrations, completeness, arrangement, appearance)
Good Fair Average Poor

Accessibility:
(Contents, index, headings, numbering)
Good Fair Average Poor
Editorial:
(Language, vocabulary, readability, clarity, technical accuracy, content)
Good Fair Average Poor
Your Please check suggestions to improve this document:
suggestions to Improve introduction Make more concise
improve the
Improve Contents Add more step-by-step procedures/tutorials
document
Improve arrangement Add more technical information
Include images Make it less technical
Add more detail Improve index

If you wish to be contacted, complete the following:


Name Company
Postcode Address
Telephone E-mail

Maipu Confidential & Proprietary Information Page 3 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

Contents

Overview ......................................................................................................6
Key Features ..........................................................................................................6
Features.................................................................................................................7
Hardware...............................................................................................................9
MP2800 Appearance...................................................................................................................9

MP2800 Front Panel....................................................................................................................9


MP2800 Router Back Panel .......................................................................................................10
MP2800 Series Router System..................................................................................................11

Functions .............................................................................................................12

Modules ......................................................................................................15
Sync/Async Serial Interface Module (SAE) Series.....................................................15
11-port High-speed V.24/V.35 Serial Module (1SAE).................................................................15

Channelized E1 Module (CE1) Series.......................................................................16


1-port Channelized E1 Module (1CE1).......................................................................................16

Non-channelized E1 Module (E1) Series ..................................................................17


1-port Non-channelized E1 Module (1E1)..................................................................................17

Frequency-band MODEM M336 Series ....................................................................18


11-port 33.6K Frequency-band MODEM (1M336)......................................................................18

ISDN (U) Series....................................................................................................19


1-port ISDN U Module (1U) ......................................................................................................19

IP Module (VOP/VOS) Series..................................................................................20


1-port IP Phone Module (1VOP) ................................................................................................20
2-port IP Phone Module (2VOP) ................................................................................................21
1-port Switch IP Phone Module (1VOS).....................................................................................22
2-port Switch IP Phone Module (2VOS).....................................................................................23

Ethernet Module (ETE) Series.................................................................................24


1-port Ethernet Module (1ETE) .................................................................................................24

ISDN S/T Module (ST) Series .................................................................................25


11-port ISDN S/T Module (1ST)................................................................................................25

ISDN S/T Module (STA) Series ...............................................................................26


1-port ISDN S/T Module (1STA) ...............................................................................................26

Asynchronous Serial Module (A) Series ...................................................................27


8-async Serial Module (8AX).....................................................................................................27

Maipu Confidential & Proprietary Information Page 4 of 47

PDF "pdfFactory Pro"


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

3G Series Module..................................................................................................28
RM2-3G-CDMA V2....................................................................................................................28

Installation.................................................................................................30
Security Suggestions.............................................................................................30
Environment Requirements....................................................................................30
Temperature & Humidity ..........................................................................................................31
Dust-free Environment .............................................................................................................31

Anti-static.................................................................................................................................32
Electromagnetic Environment Requirements.............................................................................32

Anti-lightning............................................................................................................................33

Check Routers & Accessories..................................................................................33


Tools & Equipment................................................................................................33

System Installation ...................................................................................35


Preparations .........................................................................................................35
Tools ........................................................................................................................................35
Checking Cabinet......................................................................................................................35
Checking Routers & Accessories................................................................................................36

Installing Router ...................................................................................................37


Main Control Board Cable Connection .....................................................................38
Console Port Connection ...........................................................................................................38

Grounding Wire Connection ...................................................................................38


Connecting Power Supply ......................................................................................39
Module Installation................................................................................................40
Module Installation Steps..........................................................................................................40
Module Interface Cable Connection ...........................................................................................40

Cables .........................................................................................................45
Ethernet Interface Cable........................................................................................45
Console Port Cable ................................................................................................45
RM2-1E1 & RM2-1CE1 Using RJ45-RJ45 Crossover Twisted-Pair ...............................46

Maipu Confidential & Proprietary Information Page 5 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Overview

MP2800 series router developed by Maipu is the broadband-narrowband


intelligent router integrating routing, switching, security, VoIP,
transmission, local storage, and 3G, including MP2804, MP2806, MP2816
and MP2818 models. The router integrates the Maipu Multi-service Edge
Intelligent Network (MEIN) technology to boost businesses.

The series adopts fixed and modular structure, and provides broadband-
narrowband, multi-service and intelligent solutions for users. The series
has 100M packet-forwarding capacity from LAN to WAN. It can be used to
access multi-Ethernet nodes such as network ends, PC and video monitor
in finance, securities, insurance and government industries.

The router provides many software features such as SNA/DLSw, VoIP, VPN,
MPLS, multicast, MAC address binding, and access control and bandwidth
restriction. The series provides backup schemes and QoS features. It can
be applied to multiple services such as data, video and voice.

The router series, combined with other Maipu routers, provides complete
WAN network solutions for operator, finance, government, energy sources,
traffic, education and military industries, and large/medium enterprises.

Key Features
Broadband-narrowband integration supports N*64K-100M lines

Intelligent multi-WAN load balance for coexistence of services

Provides intelligent NMS for automatically diagnosing router faults to
realize Zero-spot service

Inbuilt hardware encryption technology ensures key services of finance
system can be transmitted on IP lines

Each Ethernet port uses L2/L3 technology to realize flexible support for
services

Maipu Confidential & Proprietary Information Page 6 of 47

PDF "pdfFactory Pro"


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

High-density Ethernet port and asynchronous port to access large-


capacity Ethernet devices and traditional terminals

Hierarchical QoS ensures that the priorities of various services can be
realized on specified bandwidth of MSTP 100M port

Compatible with the routers of the main manufacturers in the industry,
which protects the original device investments and the reliable running
of the whole network.
Supports MPLS and L2TPv3 to provide strict network area division for a
single line bearing multiple services

Integrates routing, switching, security, voice, transmission, storage
and wireless

Supports secure access control and compatible with products of main
manufacturers

Features
Broadband-narrowband integration supports N*64K-100M lines
MP2800 extends features of Maipu broadband-narrowband routers and
provides several high-speed multi-function slots to access N64K, 2M
and N2M narrowband lines and realize MODEM and ISDN dial backup
schemes. The fast-forwarding engine technology developed by Maipu
makes WAN 100M line interface reach wire-speed forwarding
supporting the extension of WAN line bandwidth to 100M in advance.

Intelligent multi-WAN load balance for coexistence of services
Lower MP2800 series router assigns traffic to balance load by providing
two or above lines on access/network nodes to reach one upper server.
When some lines become invalid, traffics can be re-assigned to other
lines.

Provides intelligent NMS for automatically diagnosing router


faults to realize Zero-spot service
Inbuilt dial-up modem/console port is connected to an external dial-up
modem for remote login. Switch to remote configuration mode via
button. Then users and manufacturers can maintain devices anywhere
via telephone line dial-up to realize Zero-spot service. MP2800
supports Maipu intelligent NMS for diagnosing and fixing router faults,
automatically generating a record for users to query. In this way, it
reduces management and maintenance work of users considerably.

Inbuilt hardware encryption technology ensures key services of


finance system can be transmitted on IP lines

Maipu Confidential & Proprietary Information Page 7 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

The router provides inbuilt and highly efficient hardware encryption


engine. The encrypting data does not occupy bandwidth and CPU of the
router system realizing that high-speed encryption does not affect data
forwarding efficiency. For widely-used IP private line, encrypting data
via WAN is the safest method of ensuring the security of important
data.

Each Ethernet port uses L2/L3 technology to realize flexible


support for services
All Ethernet interfaces of MP2800 support L2/L3 technology to realize
the control for different networking modes and services, avoiding poor
control capacity caused by using Layer-2 switch and the problem that
adopting routers occupies lots of IP addresses. In this way, we can
simplify network configuration and strengthen management and
control capacity of network for services.

High-density Ethernet port and asynchronous port to access
large-capacity Ethernet devices and traditional terminals
MP2816 and MP2818 models are configured with 2+24 100M Ethernet
ports to access network terminals, PC and video terminals. Users do
not need to purchase Ethernet switches, saving network investment
and reducing faults. Considering there are some dumb terminals to
access, MP2800 has extension slots which can be extended to up to 64
asynchronous interfaces to access traditional terminals and large-
capacity Ethernet devices in network nodes/branch offices.

Hierarchical QoS
The priorities of various services can be realized on specified
bandwidth of MSTP 100M port. MP2800 supports narrowband lines and
MSTP/MPLS broadband lines. For MSTP/MPLS, the lines are for 100M
interfaces, but in fact, the bandwidth applied by users is only a part
such as 2M, 5M, 10M, 20M and 50M. Inconsistency between interface
bandwidth and practical bandwidth results in traditional QoS becoming
invalid. S0 MP2800 router adopts hierarchical QoS on Ethernet ports to
realize bandwidth control first, and then secondary bandwidth
allocation for different services. The QoS service of MP2800 router
supports RSVP, CAR and queue policies such as FIFO, PQ, CQ, FQ,
CBWFQ and LLQ to ensure priorities of key services.

Supports MPLS and L2TPv3 to provide strict network area
division for a single line bearing multiple services
MP2800 supports MPLS, L2TP and IPsec, which can be used to deploy
VPN networks from Layer 2 to Layer 3. When branch offices are inter-
connected by various lines, multiple services can be born on a single
physical network to ensure the security and save cost.

Integrates routing, switching, security, voice, transmission,


storage and 3G
MP2800 integrates routing, switching, transmission, security, local
storage and 3G. The series leads ways of edge routers - Faster, more
intelligent, more powerful. The inbuilt intelligent switch, firewall, VPN
(including MPLS VPN, IPsec VPN and L2TP VPN), VoIP and transmission

Maipu Confidential & Proprietary Information Page 8 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

service modules construct a powerful intelligent platform for different


service applications.

Supports secure access control and compatible with products of
main manufacturers
MP2800 is configured with inbuilt 802.1X and firewall. The series
provides access authentication of users and network devices in branch
offices and supports ACL packet filtering, NAT, certification audit,
routing verification, callback and refusing service protection. The router
is the first in China to realize SNA, DLSw and LLC2 protocols. It is
compatible with network devices of main manufacturers in the industry.

Structure
MP2800 series routers adopt 19 standard chassis (1U high) and can
be installed on the standard cabinet. The optimized structural design
has the features of anti-quake, anti high and low temperature, anti
electromagnetic radiation and easy to assemble and disassemble,
which makes the device work stably and reliably.

Hardware
MP2800 Appearance

MP2800 Front Panel

SYS & PWR (system and power supply indicators):


SYS - System status indicator, shining slowly after loading successfully
PWR - System power supply indicator, on after power-on

Maipu Confidential & Proprietary Information Page 9 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

CON/AUX (configuration/AUX port)


TXD - Configuration/AUX port data sending indicator
RXD - Configuration/AUX port data receiving indicator

FE0 (WAN Ethernet 0)
100M - 10/100M Ethernet interface data rate indicator
On: 100M
Off: 10M
ACT - Ethernet interface data receiving/sending indicator

FE1 (WAN Ethernet 1)
100M - 10/100M Ethernet interface data rate indicator
On: 100M
Off: 10M
ACT - Ethernet interface data receiving/sending indicator

LAN Ethernet 023
100M - 10/100M Ethernet interface data rate indicator
On: 100M
Off: 10M
ACT - Ethernet interface data receiving/sending indicator

MP2800 Router Back Panel

MP2800 series router back panel interface configuration

MP2800 series router back panel interface:


Device Interface Interface Form Slot Description
Type
MP2804 ON/OFF Power supply switch -
right OFF & left ON
INPUT AC 100-240V 1A input

Maipu Confidential & Proprietary Information Page 10 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

S0-S3 Decided by Multi-functional Multi-functional slot


interface module module
MP2806 ON/OFF Power supply switch -
MP2816 right OFF & left ON
INPUT AC 100-240V 1A input

S0-S1 Decided by Multi-functional Multi-functional slot


interface module module

S2-S5 Decided by VOP/VOS, 8AX, Private slots


interface module 1STA modules
MP2818 ON/OFF Power supply switch -
right OFF & left ON
INPUT AC 100-240V 1A input

S0-S7 Decided by Multi-functional Multi-functional slot


interface module module

For the slots of MP2806 and MP2816, only VOP/VOS series voice card
module, 8AX, 1STA, and SM1 modules can be inserted. The multi-
functional slots adopt modular design. Users can select different interface
cards and the corresponding software modules as desired.
1ETE modules are supported only by multi-functional slots S0 and S1.
The 3G module is supported only by the slot S3 of MP2804, MP2806,
MP2816, and MP2818.

MP2800 Series Router System


The basic configurations and working environment of MP2800 routers are
as follows:
Item Description
CON/AUX One (RJ45). Async DTE working mode
USB ports One
WAN Ethernet Two 10/100M fast Ethernet interface (RJ45)
interface
LAN Ethernet interface 0 (MP2804) 0 (MP2806)
24 (MP2816) 24 (MP2818)
High-speed multi- 4 (MP2804) 2 (MP2806)
functional slot 2 (MP2816) 8 (MP2818)
Private slot 0 (MP2804) 4 (MP2806)
4 (MP2816) 0 (MP2818)
AIM slot 0 (MP2804) 0 (MP2806)
0 (MP2816) 1 (MP2818)
Processor High-speed RISC processor
MONITOR 512Kbytes
FLASH 32Mbytes (MP2804) 32Mbytes (MP2806)
64Mbytes (MP2816) 64Mbytes (MP2818)
SDRAM 64Mbytes/128Mbytes/256Mbytes, optional

Maipu Confidential & Proprietary Information Page 11 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Dimension 444mm320mm44.5mm
(WDH)
Maximum weight 5.7KG
Power supply input AC: 100-240V50/60Hz
voltage AC: -40V--57V
Environment 0-40
temperature
Environment humidity 10-90%, Non-condensing
Power supply rating 70W (MP2818)
power 50W (MP2804, MP2806, MP2816)
Maximum power 27W10% (MP2804)
35W10% (MP2806)
42W10% (MP2816)
52W10% (MP2818)

Functions
MP2800 routers support the following protocols and services:
Protocol & Service Description
Network protocol WAN supports:
PPP
PPP compression
SLIP
CSLIP protocol
Frame relay
Frame relay switching
X.25
X.25 switching
HDLC
LAPB
ISDN
Virtual Ethernet bridge
Bridge
PPPoE

LAN is Ethernet supporting two kinds of link layer frame:


Ethernet-II
Ethernet-SNAP
Dialup network MODEM dialup (calling/callout)
CALLBACK
Dial-on-demand
Dialup backup
Routing protocol Static routing

Dynamic routing:
RIPv1
RIPv2
OSPF

Maipu Confidential & Proprietary Information Page 12 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

BGP
IS-IS
IRMP

Policy routing
Multicast:
IGMP
PIM-SM
PIM-SSM
PIMDM
DVMRP
Hot backup:
VRRP
VBRP (compatible with CISCO HSRP)
Network service ARP
Proxy ARP
IP UNNUMBERED
EASY IP
Load balance
MPLS
DHCP
NTP
QoS service PQ
CQ
WFQ
CBWFQ
LLQ
WRED
CAR
Traffic shaping
Network management SNMPv1SNMPv2SNMPv3
Supporting standard network management (compatible with
CISCO)
Local configuration via console port
Local or remote login via local Telnet
Configuration command security isolation function
Chinese/English prompt and help information
Detailed debugging information, for network malfunction
elimination
Log in and manage other products by Telnet
Download and upload configuration file and application
program via FTP
Download and upload configuration file and application
program via TFTP
Colorful debugging information support
Support log function
Security IP packet filter firewall
Configuration command protect ensures that unauthorized
users cannot invade the router.
PAP/CHAP
MD5

Maipu Confidential & Proprietary Information Page 13 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

NAT
RADIUS
TACACS
IPSEC data encryption
AAA
802.1x
SNA
GRE
L2TP
IKE

Maipu Confidential & Proprietary Information Page 14 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Modules

MP2800 series router is a modular router with three slots. The current
interface modules include:
1SAE
1CE1
1E1
1M336
1U
1VOP
2VOP
1VOS
2VOS
1ETE
1ST
8AX
1STA
3G
SM1

Sync/Async Serial Interface


Module (SAE) Series
11-port High-speed V.24/V.35 Serial
Module (1SAE)
1SAE module is used for MP2800 router. Its main function is to complete
data flow receiving, sending and processing.

For sync port, 2.048Mbps in DCE mode and 8 Mbps in DTE mode. For
async port, 115.2Kbps. The working mode by default is in sync mode. In
DTE mode, it uses clock from external DCE equipment such as external
sync modem. But in DCE mode, router provides clock. V24/V35 switch is
complete through panel buttons.

1SAE Interface Module


1SAE interface module:

Maipu Confidential & Proprietary Information Page 15 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

1-port high speed V.24/V.35 serial module (1SAE)

1SAE Module Connected Cable


1SAE module connected cable is V35 DTE and V24 DTE.

1SAE Interface Attributes


1-port high speed V.24/V.35 serial module (1SAE) interface attributes:
Attributes Description
Sync Async
Tie-in DB25-DB25 DB25-DB25
Interface standard & working V.24 V.35 EIA/TIA-232
mode
DTE DTE
DCE DCE
Minimum BR (bps) 1200 1200 300
Maximum BR (bps) 128K 8M 115.2K
Protocol & Service X25 Dialup
HDLC Backup
PPP HDLC
SLIP PPP
FR SLIP
LAPB

Channelized E1 Module (CE1)


Series
1-port Channelized E1 Module (1CE1)
The 1-port channelized E1 module provides multi-timeslot data flow port
with total bus transmission rate 1984K. When used as CE1 interface, it can
be divided into 1-31 timeslots, and each group works an interface after
binding.

1CE1 Interface Module & Indicator


1CE1 interface module:

Maipu Confidential & Proprietary Information Page 16 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

1-port channelized E1 module (1CE1)

1-port channelized E1 module (1CE1) indicator:


Indictor Meaning
LOS Lost indicator
On: Cannot check sync signal
Off: After sync

1CE1 Module Connected Cable


Coaxial line with BNC pin and RJ45-RJ45 connected twisted-pair.

1CE1 Module Interface Attributes


Attributes Description
Interface BNC, RJ45 (cannot be used at the same time)
Number of One group for each
interfaces
Interface standard G.703
Supported PPP
Protocol X.25
HDLC
FR

Non-channelized E1 Module (E1)


Series
1-port Non-channelized E1 Module (1E1)
The 1-port non-channelized E1 module provides 2.048 Mbit/s data
transmission port. E1 is same as CE1 interface, which can be divided into
32 timeslots physically. The timeslot 0 of E1 can be used for data
transmission in unframed mode for 2M transparent transmissions.

1E1 Module & Indicator


1E1 module:

Maipu Confidential & Proprietary Information Page 17 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

1-port non-channelized E1 module (1E1)

1-port non-channelized E1 module (1E1) indicator:


Indicator Meaning
LOS Always on: Transparent 2M transmission
On: Non-transparent and cannot check frame sync signal
Off: After sync

1E1 Interface Connected Cable


Coaxial cable with BNC pin and RJ45-RJ45 connected twisted-pair.

1E1 Interface Attributes


1-port non-channelized E1 (1E1) attributes:
Attributes Description
Interface BNC, RJ45 (cannot be used together)
Number of One group for each
interfaces
Interface
G.703
standard
Supported service X.25
FR
Supported PPP
protocol HDLC

Frequency-band MODEM M336


Series
11-port 33.6K Frequency-band MODEM
(1M336)
The 1-port 33.6K frequency-band MODEM supports sync or async mode. It
can work in private line or dialup line mode. The modem can serve as the
caller and callee. In sync mode, the clock mode includes internal clock,
external clock and sub clock; the async mode includes direct async, buffer
async, and error async.

Maipu Confidential & Proprietary Information Page 18 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

1M336 Interface & Dialup DIP


1M336 Interface & Dialup DIP

1-port 33.6K frequency-band MODEM (1M336)

1-port 33.6K frequency-band MODEM (1M336) DIP:


Mode DIP switch configuration Description
1 2
Frequency-band MODEM OFF OFF LINE port is used as inbuilt
mode frequency-band MODEM interface
Console port mode ON OFF LINE port is used as CONSOLE
port
Configure router via dialup remote
login

1M336 Interface Module Connected Cable


1M336 module connected cable is RJ45 (4, 5 signal wire) or RJ11
telephone line.

1M336 Interface Attributes


1M336 interface attributes:

1-port 33.6K frequency-band MODEM (1M336) attributes:


Attributes Description
Tie-in RJ45
Number of
1
interfaces
Supported link PPP
protocol Frame relay
X.25
HDLC
Supported network
IP
protocol

ISDN (U) Series


1-port ISDN U Module (1U)
1-port ISDN U module connects DDN network and ISDN network. It will
not connect modem.

Maipu Confidential & Proprietary Information Page 19 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

1U Module & Indicator


1U module:

1-port ISDN U module (1U)

1-port ISDN U module (1U) indicator:


Indicator Meaning
ACT Activated indicator and it is on when running normally
B1 B1 channel indicator, and it is on when using channel B1, with the rate
of B1=64K or B1+B2=128K
B2 B2 channel indicator, and it is on when using channel B2, with the rate
of B2=64K or B1+B2=128K

1-port ISDN U module (1U) DIP switch:


Mode DIP switch configuration Description
1 2
Loopback ON Reserved

1U Module Connected Cable


1U module connected cable is RJ45 (4, 5 signal cable) or RJ11 line.

1U Interface Attributes
1-port ISDN U module (1U) interface attributes:
Attributes Description
Tie-in RJ45
Number of interfaces 1
Supported link protocol PPP
Supported network
IP
protocol

IP Module (VOP/VOS) Series


1-port IP Phone Module (1VOP)
The 1-port IP phone module can access any telephone in IP network
through dialup. You can easily make a free phone call by using the set IP
network, constructing value-added network.

Maipu Confidential & Proprietary Information Page 20 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

1VOP Module &Indicator


1VOP interface module:

1-port IP phone module (1VOP) indicator:


Indicator Meaning
V1 IP phone module indicator. The light is on during the call after picking
up the phone.
V2 1VOP module may not have this light. If it has, the light will be not on

1VOP Module Connected Cable


1VOP module connected cable is RJ45 (4, 5 signal cable) and RJ11 line.

1VOP Interface Attributes


1-port IP phone module (1VOP) interface attributes:
Attributes Description
Interface RJ45 jack
Number of 1
interfaces
Supported H.225
protocol H.245
RTP
RTCP
G.711
G.723
G.729

2-port IP Phone Module (2VOP)


The 2-port IP phone module can access any telephone in IP network
through dialup. You can easily make a free phone call by using the set IP
network, constructing value-added network.

2VOP Module & Indicator


2VOP module:

Maipu Confidential & Proprietary Information Page 21 of 47

PDF "pdfFactory Pro"


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

2-port IP phone module (2VOP)

2-port IP phone module (2VOP) indicator:


Indicator Meaning
V1 IP phone module indicator
Light on: After pickup, during the call
V2 IP phone module indicator
Light on: After pickup, during the call

2VOP Module Connected Cable


2VOP module connected cable is RJ45 external cable.

2VOP Module Interface Attributes


2-port IP phone module (2VOP) interface attributes:
Attributes Description
Interface RJ45 jack (two RJ11 plugs)
Number of 2 (RJ11)
interfaces
Supported H.225
protocol H.245
RTP
RTCP
G.711
G.723
G.729

1-port Switch IP Phone Module (1VOS)


The 1-port switch IP phone module can access any telephone in IP
network through dialup. You can easily make a free phone call by using
the set IP network, constructing value-added network.

1VOS Module & Indicator

1-port switch IP phone module (1VOS)

1-port switch IP phone module (1VOS) indicator:


Indicator Meaning
V1 IP phone module indicator
Light on: during the phone call
V2 1VOS module may not have this lamp

Maipu Confidential & Proprietary Information Page 22 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Otherwise, the lamp will never be on

1VOS Module Connected Cable


1VOS module connected cable is RJ45 (4, 5 signal cable) and RJ11
telephone line.

1VOS Interface Attributes


1-port switch IP phone module (1VOS) interface attributes:
Attributes Description
Interface RJ45 jack
Number of 1
interfaces
Supported H.225
protocol H.245
RTP
RTCP
G.711
G.723
G.729

2-port Switch IP Phone Module (2VOS)


The 2-port switch IP phone module can access any telephone in IP
network through dialup. You can easily make a free phone call by using
the set IP network, constructing value-added network.

2VOS Module & Indicator


2VOS module:

2-port switch IP phone module (2VOS)

2-port switch IP phone module (2VOS) indicator:


Indicator Meaning
V1 IP phone module indicator.
Light on: During the phone call
V2 IP phone module indicator.
Light on: During the phone call

2VOS Module Connected Cable


2VOS module connected cable is RJ45 external line.

Maipu Confidential & Proprietary Information Page 23 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

2VOS Module Interface Attributes


2-port switch IP phone module (2VOS) interface attributes:
Attributes Description
Interface RJ45 jack (two RJ11 plugs)
Number of 2 (RJ11)
interfaces
Supported H.225
protocols H.245
RTP
RTCP
G.711
G.723
G.729

Ethernet Module (ETE) Series


1-port Ethernet Module (1ETE)
1-port Ethernet module realizes Ethernet connection.

1ETE Module & Indicator


1ETE module:

1-port Ethernet module (1ETE)

1-port switch IP phone module (1ETE) indicator:


Indicator Meaning
LINK On: Link connected
Tx Data sending light shining: Data sending
Rx Data receiving light shining: Data receiving

1ETE Module Connected Cable


RJ45 twisted-pair

1ETE Module Interface Attributes


1ETE module interface attributes:
1-port Ethernet port (1ETE) attributes:
Attributes Description

Maipu Confidential & Proprietary Information Page 24 of 47

PDF "pdfFactory Pro"


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

Tie-in RJ45
Number of tie-ins 1
Supported
802.3
protocol

ISDN S/T Module (ST) Series


11-port ISDN S/T Module (1ST)
1-port ISDN S/T (1ST) module provides 64K or 128K high-speed access
and backup.

1ST Module & Indicator


1ST module:

1-port ISDN S/T module (1ST)

1-port ISDN S/T module (1ST) indicator


Indicator Meaning
ACT Activated indicator and it is on when running normally
B1 B1 channel indicator, and it is on when using channel B1, with the rate of
B1=64K or B1+B2=128K.
B2 B2 channel indicator, and it is on when using channel B2, with the rate of
B2=64K or B1+B2=128K.

1ST Module Connected Cable


1ST cable is RJ45 straight-through cable.

1ST Module Interface Attributes


1-port ISDN S/T module (1ST) interface attributes:
Attributes Description
Tie-in RJ45
Number of tie-ins 1
Supported protocol PPP

Maipu Confidential & Proprietary Information Page 25 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

ISDN S/T Module (STA) Series


1-port ISDN S/T Module (1STA)
1-port ISDN S/T (1STA) module provides 64K or 128K high-speed access
and backup. It is the hardware upgrade version of 1-port ISDN S/T (1ST)
module with great slot compatibility and can be inserted to all the slots of
MP2800 routers. It also has all the software and hardware functions of 1-
port ISDN S/T (1ST) module.

1STA Module & Indictor


1STA module:

1-port ISDN S/T module (1STA)

1-port ISDN S/T module (1STA) indicator:


Indicator Meaning
ACT Activated indicator and it is on when running normally
B1 B1 channel indicator, and it is on when using channel B1, with the rate of
B1=64K or B1+B2=128K
B2 B2 channel indicator, and it is on when using channel B2, with the rate of
B2=64K or B1+B2=128K

1STA Module Connected Cable


1STA cable is RJ45 straight-through cable.

1STA Module Interface Attributes


1-port ISDN S/T module (1STA) interface attributes:
Attributes Description
Tie-in RJ45
Number of tie-ins 1
Supported protocol PPP

Maipu Confidential & Proprietary Information Page 26 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Asynchronous Serial Module (A)


Series
8-async Serial Module (8AX)
The 8-async module main function is to complete its data flow receiving
and sending only in asynchronous mode and the rate reaches 115.2K.

8AX Module
8AX interface module:

8-async serial module (8AX)

8AX Module Connected Cable


8AX module connected cable is 8-async serial cable.

8AX Interface Attributes


8-async serial module (8AX) interface attributes:
Attributes Description
Tie-in DB60
Interface standard RS-232
Minimum BR (bps) 300
Maximum BR (bps) 115.2K
Supported services Terminal (with terminal number fixed function)
ATM
PC working station
Router
Frequency-band or base-band modem
PC or router dialup
Other serial equipment
Supported protocols X.25
HDLC
PPP
SLIP

Maipu Confidential & Proprietary Information Page 27 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

3G Series Module
The RM2-3G module realizes the wireless 3G function and it can only be
inserted in the S3 slot of the MP2800 series router. It includes RM2-3G-
CDMA V2 and RM2-3G-GSM V2. ANT0 and ANT1 on the front panel are the
antenna pedestal of the 3G module respectively.

RM2-3G-CDMA V2
The RM2-3G-CDMA V2 module needs to be inserted with the CDMA2000
3G module and USIM card.

RM2-3G-CDMA V2 Module and Indicators


RM2-3G-CDMA V2 module:

The indicators of RM2-3G-CDMA V2 module:


Indicator Color Meaning
Off: Not power on
WWAN Green
On: Power on
Off: Weak signals <= -116dBm
RSSI Green On: Strong signals >= -78dBm

Flash: -78dBm > Middle/low signals > -116dBm


Off: No 1xRTT service
1xRTT Green
On: With 1xRTT service
Off: No EVDO service
EVDO Green
On: With EVDO service

RM2-3G-GSM V2
The RM2-3G-GSM V2 module needs to be inserted with WCDMA 3G
module and USIM card.

RM 2-3G-GSM V2 M odule and I ndic at ors


The RM2-3G-GSM V2 module:

The indicators of the RM2-3G-GSM V2 module:

Maipu Confidential & Proprietary Information Page 28 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Indicator Color Meaning


Off: Not power on

On: With service, but not enter the data mode


Green and flash slowly: Searching service (off for
4.75s and on for 0.25s.
WWAN Green
Green and flash quickly: with service and enter data
mode (The quick flashing frequency is related with
received data traffic. The larger the data traffic, the
faster the flashing. When there is no traffic, flash
with an interval of 4s).

Off: Weak signals <= -103dBm


RSSI Green On: Strong signals >= -55dBm

Flash: -55dBm > Middle/low signals > -103dBm


Off: No HSDPA service
HSDPA Green
On: With HSDPA service

Off: No GSM/GPRS service


UMTS Green
On: With GSM/GPRS service

SM1 Module
The RM2-SM1 module is used for the hardware encryption and decryption.
The RM2-SM1 module panel does not have external interfaces.

RM2-SM1 Module
The RM2-SM1 interface module:

The meanings of the RM2-SM1 module indicators:


ACT On: Some data is encrypted/decrypted
Off: Idle

RDY On: The card is available, that is, RDY and ENABLE are valid at the same time
Off: The card is unavailable
Flash: The card is RDY, but the host is not enabled (Enable)

Maipu Confidential & Proprietary Information Page 29 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Installation

Security Suggestions
To avoid the harms on persons and equipments caused by various
accidents, comply with the following:

Keep the router far away from humid places and heat

Ensure that router is well grounded

Wear anti-static wrists during installation and maintenance

Do not install, move and dismantle routers and modules during power
on to avoid damages on persons and equipments

Do not hot swap interface modules and interface cards of routers

Do not hot swap cables

Connect the interface cables of routers correctly, especially do not
connect phone lines (including ISDN lines) to serial ports

Use Uninterrupted Power Supply (UPS)

Router AC power supply is soft start control switch, which does not cut
the main return circuit of AC power supply. During installation, the
control switch of main return circuit so as to cut down power supply
fast in case of accidents.

Environment Requirements
MP2800 series routers must be used indoor. To guarantee stable use of
routers, the application scenario must meet the following requirements.

Maipu Confidential & Proprietary Information Page 30 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

Temperature & Humidity


To ensure the service quality and life of MP2800 series routers, it is
recommended to maintain a certain temperature and humidity in the
computer lab. If the humidity in the computer lab is high for long time, it
causes the poor insulation and even electricity leak of insulation materials
easily.

Sometimes, the mechanical performances of materials change and the


metal parts are corroded easily, too. If the relative humidity is too low,
insulation pads shrink, which causes the fastened screws loose. Meanwhile,
in dry environment, static electricity appears easily, which harms the
circuits on the router.

If the temperature is too high, the reliability of the router reduces greatly.
The long-time high temperature affects the life and speeds up the aging of
insulation materials.

The recommended temperature and humidity in computer room:


Temperature Relevant humidity
Long-term Short-term Long-term Short-term

15-30 0-40 40%-65% 10%-90%


Measuring points of the working temperature and humidity of MP2800
in the computer room mean the values measured from the floor above
1.5 m and 0.4 m from the front of the rack when there are no
protection boards.

The short-term working condition means less than 48h continuously
and less than 15 days for the annual total.

Extreme adverse working environment means the environment
temperature and humidity when the air-conditioning system in the
computer room fails. Each time the normal work should be recovered
within less than 5h.

Dust-free Environment
Dust is harmful for MP2800 operation. Dust causes static absorption,
which makes the poor contact of metal pieces. Static absorption appears
especially when the temperature and humidity are lower, which affects the
device life and causes communication fault.

Dust requirements for the room:


Maximum diameter (m) 0.5 1 3 5
5 5 5
Maximum concentration (contained 1.4107 710 2.410 1.310
3
particles per m )

Maipu Confidential & Proprietary Information Page 31 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

Apart from dust, the router has strict requirements for SO2, H2S, NH3,
and Cl2 in the room, because these harmful gases speed up the eroding of
metals and the aging of some components.

The specific limitations are as follows:


3
Gas Maximum value (mg/m )
SO2 0.2
H2S 0.006
NH3 0.05
Cl2 0.01

Anti-static
MP2800 router takes lots of measures in anti-static, but when the static
exceeds a certain volume, the circuits even the whole monitor are
damaged.

For router communication, static electricity originates from external


electric field of high-pressure like electricity cables and thunders, and
internal system such as floor material and chassis structure. To prevent
the damage caused by the static, do as follows:

Ensure proper equipment grounding



Maintain dustproof room

Keep suitable temperature & humidity

Wear anti-static equipment

Place the disassembled circuit board on the anti static workstation and
keep the face upturned or in the anti static bag

When viewing or removing the disassembled circuit board, touch the
edge of circuit board and avoid touching the components on the circuit
board.

Electromagnetic Environment
Requirements
The various interference sources, no matter from the exterior of devices or
application systems or from the interior, affect the devices through
capacitance coupling, inductance coupling, electromagnetic radiation,
public impedance (including grounding system) and lead (such as power
lines, signal lines and output lines).

Maipu Confidential & Proprietary Information Page 32 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

Therefore, pay attention to the following:

Take anti-electric network interference for power system.



The router working place had better not be used with the grounding
settings of power devices or anti-thunder grounding settings and the
distance between them had better be as long as possible.

Be away from the strong power radio transmitters, radar transmitter,
and high frequency high-current equipments.

Take electromagnetic shielding methods when necessary.

Anti-lightning
MP2800 router takes lots of measures in anti-lightning, but when the
lightning exceeds a certain volume, the router may be damaged. To
prevent the damages caused by lightning, do as follows:
Ensure that the protect ground of the chassis is well grounded;

Ensure that the grounding point of AC power supply jack is well
grounded;
Add power lightning arrester to the input end of the power supply, so
as to improve the anti-lightning capability of the power supply;

To improve the anti lightning capability, the MP2800 interface modules
are connected to outdoor signal lines. You can add special anti-
lightning equipment to the input end of signal lines.

Check Routers & Accessories


After ensuring the installation environment requirements are met, you can
open the package. However, before installation, check whether the router
and the accessories are complete according to the purchase order.

Tools & Equipment


Tools
Slotted point screwdriver/cross point screwdriver

Level, ruler or tapeline

Maipu Confidential & Proprietary Information Page 33 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2


Anti-static equipment

Connected cables
Cables in the package

Equipment
HUB or Ethernet switch

Configuring terminal (can be PC)

Maipu Confidential & Proprietary Information Page 34 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

System Installation

Preparations
Tools
Before installation, prepare slotted point screwdriver/cross point
screwdriver, level, ruler or tapeline, and anti-static equipment

Checking Cabinet
Maipu devices are designed according to the dimension of 19-inch
standard cabinet, so they can be installed and fixed normally on 19-inch
standard cabinet. Before installation, reserve enough slot room for
installing the device.

Center distance of the horizontal installation hole and net horizontal


direction installation space of the cabinet

Use ruler or tapeline to measure the center distance of the horizontal


installation hole and net horizontal installation space of the cabinet.

Check whether the pallet bracket, floating nut, fixed screw, and baffle

Maipu Confidential & Proprietary Information Page 35 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

board on the cabinet are complete, which are the standard accessories.
Different cabinets have different dimensions and shapes. Therefore, to add
cabinet accessories, contact the supplier of the cabinet to provide genuine
accessories.

The device must be installed on the pallets or trays (used in pairs) of the
cabinet. Therefore, install the pallets or trays on the cabinet before
installing the device as follows. Use the level to check whether the pallets
or trays are horizontal. If not, adjust the fixed bolt of pallet or tray to
make the pallet or tray horizontal and then fasten it.

Check whether the floating nut for fixing the device is installed in the
square hole of the cabinet column. If not, insert the floating nut to the
square hole according to the position of the pallet or tray.

Usually, it is required that one device is placed on a pallet or a bracket. It


is not recommended to overlap multiple devices.

Checking Routers & Accessories


After ensuring the installation environment requirements are met, open
the package and check whether the router and the accessories are
complete according to the purchase order.

If there is some missing or damaged items in the package, contact the
equipment dealer or sales.

During check, place router and accessories at safe place to avoid falling
down or impacting; keep the router far away from the places with
liquids, toxic gases and dust to avoid damages on the router.

Maipu Confidential & Proprietary Information Page 36 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

When moving or checking the device, wear gloves to avoid the


corrosion of metal parts caused by perspiration.

Keep all packaging materials for later use during transporting.

Installing Router
Install MP2800 router to the cabinet as follows.


Step 1: Wear gloves and anti-static wrist and make the anti-static
reliable grounding

Step 2: Place the device on the fixed platform. Align the installation
hole of the bracket and the corresponding place of the device. Use the
screw to fix the bracket on the two sides of the device.
Step 3: The front of the device faces the operator. Use the hands to
stabilize the device and keep it horizontal. Place the device from the
cabinet front to the pallet or bracket carefully and avoid that the device
hits the cabinet columns. For the heavy or high device, two persons
had better cooperate to handle it.

Step 4: Use two hands to push the device and make the bracket of the
device close to the surface of the cabinet column.

Step 5: Use fixed screw to install the device on the column of the
cabinet.

Step 6: Check whether the device is installed on the bracket fixedly
and straight.

Step 7: Check the space between the installed devices. Choose the
desired cabinet baffle board (it is the standard accessory of the shelf)
to be placed in the space between the devices. Use the screws to fix
baffle board on the shelf.

Maipu Confidential & Proprietary Information Page 37 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Installation suggestions:
When installing various devices on a cabinet, consider installing heavy
devices at the bottom of the cabinet or close to the bottom so as to lower
the cabinets center of gravity and improve the stability.

When installing devices in the cabinet, it is recommended to reserve a


space of 1U height between devices to ensure the space for heat
dissipation of devices. Install the baffle board configured with the cabinet
in the space between devices.

Main Control Board Cable


Connection
This section describes the method of connecting MP2800 control board
cables to the network, including connecting router console port.

Console Port Connection


MP2800 router provides one EIA/TIA-232 async serial console port. The
user configures the router via the port by adopting RS-232 serial character
terminal (normally a PC).

For the detailed connection and configuration, refer to the later chapter.
Configure the router via the terminal as follows:

Step 1: Find a character terminal a standard terminal with RS-232


serial or normal PC. The latter is more common.

Step 2: Ensure that router or terminal is out of power supply and


connect RS-232 serial and console port with cables.

During the connection, make sure about the ID on the interface to avoid
inserting to other interfaces.

Grounding Wire Connection


The normal connection of MP2800 ground wire is the first guarantee of
anti-thunder and anti-interference of the router. It is required that users
must connect the ground wires correctly.

AC noise filter is connected to the AC input end of router power supply,


whose center is connected with chassis. The chassis ground (that is
protect ground) must be connected to the ground, so as to make induction
electricity and leaked electricity flow to the earth and improve the feature
of anti electromagnetic interference.

For external network connection such as E1 interface, grounding cable


protects the PSTN. The grounding wire also protects the thunder high

Maipu Confidential & Proprietary Information Page 38 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

voltage from the external network connection such as E1 interface and


PSTN.

Connect this point and ground it by a thick cable with resistance not bigger
than 4. If the router is installed on 19-inch standard cabinet, the cabinet
should be grounded.

Connecting Power Supply


MP2800 router adopts stable power supply switch system and has a low
requirement for input AC. In China, adopt 220V and 50Hz AC, which is a
civilian electricity standard. Different areas have different power supply
systems.

MP2800 router input power supply requirements are as follows:



AC input power supply: 100-240V, 50/60Hz
DC input power supply: 40-57V
Maximum power: 27W10% (MP2804)
35W10% (MP2806)
42W10% (MP2816)
52W10% (MP2818)

When connecting power supply, use the below suggested power supply
jack or MIM PC power supply jack for reliable grounding. When laying
cables for buildings, the ground wires of the power supply system have
been installed underground. Users should ensure the reliable grounding
and make the corresponding processing.

Ground wire

Naught wire Live wire

Common power supply jack

Connect the power supply as follows:

Step 1: Put the power supply switch to OFF. For AC router, connect
one side of AC power supply cable to the AC power input end of the
back panel of the router and another side to power supply jack (AC:
220V 50Hz/60Hz) and use the clip to lock the cable; for DC router,
connect the power line to the post according to the description of panel
silk screen on the interface. The cross sectional area of the lead of the
selected power line must be larger or equal to 2 mm2.

Maipu Confidential & Proprietary Information Page 39 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Step 2: Put power supply switch to ON.

Step 3: Check whether the power supply indicator of the front panel is
on. If not, repeat step 1 and 2. If the power supply indicator is not on
after repeating the above steps, contact the agent.

Module Installation
Module Installation Steps
MP2800 series router adopts modular structure and provides the capacities
of configuring various interfaces according to users requirements. The
installations of various modules are simple and convenient, as follows.

Installing MP2800 series modules


The steps for installing modules:
Choose the desired modules and interfaces (for the corresponding
relationship of modules and slots, refer to the interface table of the
back panel of MP2800 router).

Insert the module to slot. Insert the module circuit board into interface
card slot.

Push in the module close to back panel.

Tighten the screw.

According to the contrary order, you can dismantle the modules.

Module Interface Cable Connection


1SAE Module Interface Cable Connection
This section describes the notes of 1SAE module and cable connection.
Before connecting sync/async serial, ensure the following two points:
The equipment type connecting sync/async serial, which is sync/async
or DTE/DCE

Maipu Confidential & Proprietary Information Page 40 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Access equipment requires signal standard, baud rate and sync clock.

DTE and DCE:
Sync/async serial port accesses external Modem or TA (terminal adapter)
as dialup interface. Sync serial port has two modes - DTE and DCE. The
two direct connected devices work in DTE and DCE respectively.

The device at the DCE side provides the synchronization clock and
specifies the communication rate, while DTE device receives the
synchronization clock and communicate according to the specified baud
rate.

The router usually serves as DTE. For the type of the device connected to
the router, refer to the manual of the device. The following table can also
help you determine the device type.

Typical DTE and DCE equipment:


Device Type Interface Type Typical Device
DTE Pin type PC
router
DCE Hole type MODEM
Multiplexer
CSU/DSU

Rate and transmission distance:


Sync/async serial supports different signal standards and baud rates in
different working modes. Choose cables as per prevailing conditions. The
maximum transmission distance and baud rate of signals are related with
the cables.

V.24 cable rate and transmission distance:


Baud rate (bps) Maximum transmission distance (m)
2400 60
4800 60
9600 30
19200 30
38400 20
64000 20
115200 10

V.35 cable rate and transmission distance:


Baud rate (bps) Maximum transmission distance (m)
2400 1250
4800 625
9600 312
19200 156
38400 78
56000 60

Maipu Confidential & Proprietary Information Page 41 of 47

PDF "pdfFactory Pro"


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

64000 50
2048000 30

When EIA/TIA-232 cable is adopted, BR rate cannot be over 64Kbps.


Connect the cables of synchronous/asynchronous modules as follows:

Step 1: Insert one side of DB-25 to the DB-25 interface of 1SAE


module and screw down fixed knob.

Step 2: Connect another DB25 interface to V.24-V.35 (DB-25, M-34)


cable and then connect the following equipment:

If WAN is DDN line, connect (V.35 cable) to digital Modem V.35 interface.
If WAN is dialup line, connect (V.24 cable) to analog Modem serial.

During the connection, make sure about the ID on the interface to avoid
inserting to other interfaces, which causes the damage of modules and
router host.

1CE1/1E1 Module Interface Cable Connection


Connect 1CE1/E1 interface as follows:

Step 1: Connect one side of BNC plug to BNC interface of 1CE1/E1


module.

Step 2: Connect another side to the corresponding equipment.
Connect TX to RX equipment. Connect RX to TX line.

Step 3: After power on, check LOS status of 1CE1/E1 module.


Indicator on means malfunction and signal loses sync. Then check the
line. In E1 transparent 2M mode, the asynchronous indicator is always
on.

For RJ45 interface, use RJ45-RJ45 crossover twisted pair to connect. BNC
and RJ45 interface cannot be used together.

During the connection, make sure about the ID on the interface to


avoid inserting to other interfaces, which causes the damage of
modules and router host.

For E1 module, asynchronous indicator is always on in transparent 2M
mode; in non-transparent mode, the indicator is on when frame
synchronous signals are not checked. After synchronization, the
indicator is off.

1M336 Module Interface Cable Connection


Insert RJ11 plug of 1M336 module cable to LINE jack.

During the connection, make sure about the ID on the interface to avoid
inserting to other interfaces, which causes the damage of modules and

Maipu Confidential & Proprietary Information Page 42 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

router host.

1U Module Interface Cable Connection


Step 1: Insert RJ11 plug of 1U cable to LINE jack. Connect another
side to the external lines.

Step 2: After power on, please check ACT status of 1U interface


module. If the indicator is off, please check the line.

During the connection, make sure about the ID on the interface to avoid
inserting to other interfaces, which causes the damage of modules and
router host.

1VOP/2VOP Module Interface Cable Connection


Step 1: Insert telephone line to RJ11 interface of 1VOP/2VOP, and another
side to telephone.

Step 2: When having the phone call, pay attention to the indicator of
1VOP/2VOP card back panel. During the call, the indicator of each channel
should be on.

During the connection, make sure about the ID on the interface to avoid
inserting to other interfaces, which causes the damage of modules and
router host.

1VOS/2VOS Module Interface Cable Connection


Inset telephone line to RJ11/RJ45 interface of 1VOS/2VOS and another
side to small switch or external junction box.

When having the phone call, pay attention to the indicator of


1VOS/2VOS card back panel. During the call, the indicator of each
channel should be on.

During the connection, make sure about the ID on the interface to avoid
inserting to other interfaces, which causes the damage of modules and
router host.

1ETE Module Interface Cable Connection


Inset RJ45 plug of 1ETE cable to RJ45 jack.

Connect another side of RJ45 plug to equipment wire.



During the connection, make sure about the ID on the interface to
avoid inserting to other interfaces, which causes the damage of
modules and router host.

1ST/1STA Module Interface Cable Connection


Inset RJ45 plug of 1ST/1STA cable to RJ45 jack.

Maipu Confidential & Proprietary Information Page 43 of 47

PDF "pdfFactory Pro" www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Connect another side of RJ45 plug to equipment wire.

8AX Module Interface Cable Connection


Inset DB60 plug of 8AX cable to 8AX jack. Screw down the fixed knob

Connect another side of RJ45 plug to equipment wire.

During the connection, make sure about the ID on the interface to avoid
inserting to other interfaces, which causes the damage of modules and
router host.

Maipu Confidential & Proprietary Information Page 44 of 47

PDF "pdfFactory Pro" (www.fineprint.com.cn


MP2800 Series Router Install Manual V1.2

Cables

Ethernet Interface Cable


MP2800 Ethernet interface cable is 8-core non-screen twisted-pair. Silver
plate1/2 are sending end and silver plat 3/6 are receiving end. RJ45
straight connected cable (type-5 twisted-pair) connection relation:

RJ45 Signal Direction RJ45 Description Length


1 TX0+ > 1
Twisted-pair 1
2 TX0- > 2
3 RX0+ < 3
Twisted-pair 2
6 RX0- < 6
2m
4 ---- ---- 4
Twisted-pair 3
5 ---- ---- 5
7 ---- ---- 7
Twisted-pair 4
8 ---- ---- 8

RJ45 cross cable (type-5 twisted-pair) connection relation:


RJ45 Signal Direction RJ45 Description Length
1 TX+ > 3
Twisted-pair 1
2 TX- > 6
3 RX+ < 1
Twisted-pair 2
6 RX- < 2
2m
4 --- --- 7
Twisted-pair 3
5 --- --- 8
7 --- --- 4
Twisted-pair 4
8 --- --- 5

Console Port Cable


MP2800 console port cable is connected with PC 9-core serial jack, and it
is 8-core non-screen cable. One side is RJ45 plug and another is DB9
(hole).

Maipu Confidential & Proprietary Information Page 45 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

RJ45 jack Standard DB9 interface

Console port cable connection relation:


RJ45 Signal Direction DB9 Length
1 CTS > 8 3m
2 DSR > 6
3 RXD > 2
4 GND --- 5
5 --- --- ---
6 TXD < 3
7 DTR < 4
8 RTS < 7
--- --- 1
--- --- 9

RM2-1E1 & RM2-1CE1 Using


RJ45-RJ45 Crossover Twisted-
Pair
If RJ45-RJ45 crossover twisted-pair is needed when using RJ45 interface
of E1 and CE1 cards, make the cables according to the cable sequence
described in the following table.

RJ45 Signal Direction RJ45


1 RX+ < 4
2 RX- < 5
3 --- --- 7
6 --- --- 8
4 TX+ > 1
5 TX- > 2
7 --- --- 3

Maipu Confidential & Proprietary Information Page 46 of 47

PDF "pdfFactory Pro"


www.fineprint.com.cn
MP2800 Series Router Install Manual V1.2

8 --- --- 6

RJ45 interface cable sequence

Maipu Confidential & Proprietary Information Page 47 of 47

PDF "pdfFactory Pro" (


www.fineprint.com.cn

Das könnte Ihnen auch gefallen