3. Feed
In the Current Process, Feed stream from well is supplied at Kpa and c .
4. Mixed refrigerant
liquefaction. The refrigerant mixture evaporates over a temperature range similar to that of the process
cooling demand. The desired result is that the temperature enthalpy warming curve of the mixed
refrigerant closely tracks the natural gas cooling curve in the main heat exchangers This reduces the
energy demand of the process. The mole fractions of refrigerants composition were obtained
either by trial and error method based on cooling curves appeared in the main heat exchangers.
The mole fraction of refrigerants' composition were obtained either by trial and error method
based on cooling curves appeared in the main heat exchangers The composition of the refrigerant
Mole Fraction
Methane 0.32
Ethane 0.33
Butane 0.1
Nitrogen 0.25
Energy analysis
It is known that the main energy demand for liquefaction processes is the energy consumed at the
k-101 9372
k-102 2485
k-103 2672
k-106 3.51
TOTAL 14532.51
8676
q = m X Heating value = 3600 49.723 103 = 119859 Kw
1198590
= = 8.248
14532.510