Quick Guide for GT01W Basic unit

2016-06-13, JoMe

GT01W0230, GT01W0048 TANGRAM Basic Unit

Basic unit for the modules


Edge Modules
GT21 Edge PAL
GT22 Edge FM
GT23 Edge QAM
GT24 Edge COFDM
GT26 Edge ISDB-T
Reception Modules
GT31 DVB-S/S2/C/T/T2/ISDB-T IP Gateway
GT32 ASI - IP
GT33 ATSC IP Gateway
Transcoder Modules GT37 Linear Transcoder

Scrambler and Descrambler Module


GT41 IP Processing Module
GT42 CI Descrambler
NOTE:

This Quick Guide is used primarily for commissioning the unit at start-up by providing the parameters
necessary to start operation. Details for mechanical information, safety information, configuration
and handling of these products are provided in the manual and configuration guide.

WISI Communications GmbH & Co. KG www.wisi.de


2-8

Content

1 Safety and Agency Approvals ............................................................................................................... 3


1.1 Legal Reference and Safety Standards ......................................................................................... 3
1.2 Electrical Safety ............................................................................................................................ 3
1.3 ESD Protection .............................................................................................................................. 3
2 Assembling chassis and modules.......................................................................................................... 4
2.1 Assembling the GT-modules ......................................................................................................... 4
2.2 Assembling the redundant Power-Supply .................................................................................... 4
3 Fitting and connecting the cables......................................................................................................... 5
3.1 Rack fitting with montage set ....................................................................................................... 5
3.2 Backside ........................................................................................................................................ 6
3.3 Frontside ....................................................................................................................................... 6
4 Connecting to the TANGRAM Web UI .................................................................................................. 6
4.1 Default IP address ......................................................................................................................... 6
4.2 Changing IP address...................................................................................................................... 6
5 Important information and maintenance ............................................................................................ 7
5.1 Operating System notes ............................................................................................................... 7
5.2 Changing the Fan-unit (a) ............................................................................................................. 7
5.3 Changing the power supply GT55W (b) ..................................................................................... 8
5.4 Article Numbers Spare Parts...................................................................................................... 8
6 Service and Support.............................................................................................................................. 8

WISI Communications GmbH & Co. KG www.wisi.de


3-8

1 Safety and Agency Approvals

1.1 Legal Reference and Safety Standards


Operation of optical communication systems is subject to national and/or international safety
regulations (GT12W with optical SFPs).
We refer to:
European directive 2006/25/EC on the minimum health and safety requirements regarding the
exposure of workers to risks arising from physical agents (artificial optical radiation),
International standard IEC 60825-1 (2007-03): Safety of laser products - Part 1: Equipment
classification and requirements, and
International standard IEC 60825-2 (2010-12): Safety of laser products - Part 2: Safety of optical
fiber communication systems (OFCs).

Generally, the operator of a communication system is responsible for its safe operation. Some
important points to respect are e.g.
Assessment of hazard levels at accessible locations,
Care for the proper installation and maintenance,
Measures for the safe operation, like access control and adequate staff training.

1.2 Electrical Safety


The TANGRAM equipment must be grounded in accordance with local and national electrical standards.
Risk of bodily injury from electric shock! Failure to adhere to these instructions could result in personal
injury and/or damage to electrical components.
Each power supply unit must be switched on or off using a circuit breaker which have to be
implemented as part of the building wiring.
Each shelf and the rack must be properly grounded before power is applied by turning on the
respective circuit breaker.

1.3 ESD Protection


This product contains electrostatic sensitive devices. These devices can be damaged or effectively
destroyed by electrostatic discharge (ESD) during unpacking, installation, removal, storage, or shipment
if incorrectly handled.

Please note that discharge might go unnoticed by a user. Always take normal
static precautions when handling the equipment!

WISI Communications GmbH & Co. KG www.wisi.de


4-8

2 Assembling chassis and modules

2.1 Assembling the GT-modules


Turn the GT01W on the backside and insert the GT-modules.
Fix the GT-modules with delivered screws.

2.2 Assembling the redundant Power-Supply


Remove the cover plate from TANGRAM (a).
Insert redundant power unit (b).
Connect the redundant Power-Supply unit with an AC or DC power cable (c).
(Please note for DC PSUs, you need a cable montage set GT98)

(b)

(c)
(a)

WISI Communications GmbH & Co. KG www.wisi.de


5-8

3 Fitting and connecting the cables

3.1 Rack fitting with montage set


Tangram is a high-density device, so it is very important for stable operation that there is sufficient
ventilation and cooling.

Ensure that air flow is not blocked at the side vent holes.
Ensure that the guide rail do not cover the ventilation ways.

The air flow is shown in the following figure. The blue arrows [ ] show the incoming (cold) air, red
arrows [ ] the outgoing.

The Tangram platform is mounted into a standard 19-inch rack using rack mount brackets for both the
front and rear of the system. Do not mount into any rack that obstructs clean air flow. Generally, an
aisle of at least 5 cm to all sides is the minimum distance to ensure proper air flow.

While Tangram does not require spacing above and below it, it is generally recommended that 1 rack
unit of spacing is left above and below, especially if non Tangram devices will be mounted above or
below it.

It is recommended in the top rack to install block ventilation to remove heated air. It is
mandatory if a fully closed rack is used.
For the installation it must be taken into account that the front brackets are not designed to
hold the chassis without additional support. Therefore, to ensure structural rigidity while
maintaining the free path for the passage of air it is recommended to use a back support.

WISI Communications GmbH & Co. KG www.wisi.de


6-8

3.2 Backside
Connect the GT01 chassis with grounding (a).
Connect the GT01 Power-Supply with AC (b) or DC power; it is depending of the ordered article
number.
Connect the Input-Signals (for example GT31 DVB-C/S/S2/T) or Output-Signals (for example
GT23 QAM) to each module.
The control port of each module is only for a local management (default IP address:
192.168.1.20).
Control Port for local
Management

(a) grounding

(b) AC power cable


(b) AC power cable
redundant PSU

3.3 Frontside
Connect a network cable on the Management Port for GT11
Connect a network cable on the streaming ports
4x RJ45 ports (internal
switch) for input/output
transport streams

1x RJ45 port for


manage the GT11 and
all modules

4 Connecting to the TANGRAM Web UI

4.1 Default IP address


Connecting to the default IP address: 192.168.0.11

The default IP address of the TANGRAM GT11 (internal Switch) on the Management port is
192.168.0.11. Set the IP address on your computer or for your network adaptor to an address in the
same address range. Use a standard web browser to connect by typing the IP address of the TANGRAM
in the address field.

4.2 Changing IP address


It is recommended to change to a unique IP address in your network. You can change the IP address
under WISI Control GT11 Settings Networking Edit Settings

WISI Communications GmbH & Co. KG www.wisi.de


7-8

5 Important information and maintenance

5.1 Operating System notes


The ventilation is important to prevent the overheating of the Tangram.
Ensure that the ventilation-ways are free.
Ensure that there is free space at the rear side.
Ensure that the guide rail not cover the ventilation ways.
Operation of the Tangram is only allowed while the fans are running.
The Tangram module includes a temperature-sensor, so if it is too hot for the Tangram module,
it stops running without a warning signal.
If the fan-unit is running, the DC-power unit works correctly

Condition Limits
Permissible operating temperature inside -5+45 C (ETSI EN 300 019-1-3 Class 3.1)
Recommend operation range of +15+35 C
Humidty Up to 95%, non-condensing

5.2 Changing the Fan-unit (a)


Changing the fan unit is possible while device is running
Remove the front cover plate
Pull on the handholds and pull out the fan unit
Insert the new fan unit

WISI Communications GmbH & Co. KG www.wisi.de


8-8

5.3 Changing the power supply GT55W (b)


If there is a redundant power supply unit inside and working, it is possible to change 1 power
unit while device is running.
Disconnect the AC or DC Power cables and remove the power-supply-unit.
Insert the new power-supply-unit and connect the power card.

(a)
(b)

5.4 Article Numbers Spare Parts

HW Name Description Number


GT01W0048 Tangram chassis, 48V DC 72235
GT01W0110 Tangram chassis, 110V AC 73597
GT01W0230 Tangram chassis, 230V AC 71161
Technical Modifications reserved. WISI cannot be held liable for any printing error. 412919d/ 04.15

GT55W0048 Redundant PSU, 48V DC 71265


GT55W0110 Redundant PSU, 110V AC 71265
GT55W0230 Redundant PSU, 230V AC 71234
GT11 GT11 Switch unit 71156
GT98 Cable montage set for 48V DC 73344
Fan unit 27245

6 Service and Support


For support information and help, please contact our support organisations by submit a ticket via
wisiconnect.tv portal. Support requested by email will be not processed.

WISI Communications WISI Norden AB


Telephone: +49 7233 66-621 Telephone: +46 13 21 09 15

Visit www.wisiconnect.tv for more information about configuration, Software, Entitlements and
Product information.

WISI Communications GmbH & Co. KG


Empfangs- und Verteiltechnik
Wilhelm-Sihn-Strasse 5-7 Inland: Phone +49 7233-66-0 Fax -320
75223 Niefern-schelbronn Export: Phone +49 7233-66-280 Fax -320