This Quick Guide is used primarily for commissioning the unit at start-up by providing the parameters
necessary to start operation. Details for mechanical information, safety information, configuration
and handling of these products are provided in the manual and configuration guide.
Content
Generally, the operator of a communication system is responsible for its safe operation. Some
important points to respect are e.g.
Assessment of hazard levels at accessible locations,
Care for the proper installation and maintenance,
Measures for the safe operation, like access control and adequate staff training.
Please note that discharge might go unnoticed by a user. Always take normal
static precautions when handling the equipment!
(b)
(c)
(a)
Ensure that air flow is not blocked at the side vent holes.
Ensure that the guide rail do not cover the ventilation ways.
The air flow is shown in the following figure. The blue arrows [ ] show the incoming (cold) air, red
arrows [ ] the outgoing.
The Tangram platform is mounted into a standard 19-inch rack using rack mount brackets for both the
front and rear of the system. Do not mount into any rack that obstructs clean air flow. Generally, an
aisle of at least 5 cm to all sides is the minimum distance to ensure proper air flow.
While Tangram does not require spacing above and below it, it is generally recommended that 1 rack
unit of spacing is left above and below, especially if non Tangram devices will be mounted above or
below it.
It is recommended in the top rack to install block ventilation to remove heated air. It is
mandatory if a fully closed rack is used.
For the installation it must be taken into account that the front brackets are not designed to
hold the chassis without additional support. Therefore, to ensure structural rigidity while
maintaining the free path for the passage of air it is recommended to use a back support.
3.2 Backside
Connect the GT01 chassis with grounding (a).
Connect the GT01 Power-Supply with AC (b) or DC power; it is depending of the ordered article
number.
Connect the Input-Signals (for example GT31 DVB-C/S/S2/T) or Output-Signals (for example
GT23 QAM) to each module.
The control port of each module is only for a local management (default IP address:
192.168.1.20).
Control Port for local
Management
(a) grounding
3.3 Frontside
Connect a network cable on the Management Port for GT11
Connect a network cable on the streaming ports
4x RJ45 ports (internal
switch) for input/output
transport streams
The default IP address of the TANGRAM GT11 (internal Switch) on the Management port is
192.168.0.11. Set the IP address on your computer or for your network adaptor to an address in the
same address range. Use a standard web browser to connect by typing the IP address of the TANGRAM
in the address field.
Condition Limits
Permissible operating temperature inside -5+45 C (ETSI EN 300 019-1-3 Class 3.1)
Recommend operation range of +15+35 C
Humidty Up to 95%, non-condensing
(a)
(b)
Visit www.wisiconnect.tv for more information about configuration, Software, Entitlements and
Product information.