BUCHHOLZ RELAYS
BUCHHOLZ RELAYS
Purchase orders should be given in accordance Orderin System
with the following chart.

TYPE UPPER CONTACT SYSTEM

ABR25-V50 (DG-25) 741 Standart Reed Switch Normally Open (R-NO) 1


ABR25-F50 (DR-25) 751 Standart Reed Switch Normally Closed (R-NC) 2
ABR50-F100 (DR-50) 761 Changeover Reed Switch (W) 3
ABR80-F100 (DR-80) 771 Without Contact (0) 0

LOWER CONTACT SYSTEM


OIL FLOW SPEED SETTING

Standart Reed Switch Normally Open (R-NO) 1


1,00 m/s 2
Standart Reed Switch Normally Closed (R-NC) 2
1,50 m/s 3
Changeover Reed Switch (W) 3

COLOR DESCRIPTION

RAL 1016 01
RAL 7001 02
RAL 7012 03
RAL 7016 04
RAL 7022 05
RAL 7032 06 2 Normally Open Contact 03
RAL 7033 07
RAL 7035 08
RAL 7037 09
RAL 7038 10
RAL 9002 11

Example:
AMBR25-F50: 751. 1. 1. 2. 01- (01) BUCHHOLZ RELAY FOR CONTACT CONNECTION DETAILS 9 or 10 See page

1
BUCHHOLZ RELAYS
INTENDED USE OF BUCHHOLZ RELAY AN-50216-2
On power and distribution transformers with oil conversator,
protection relays manfactured by Buchholz principle are mounted
between transformer tank and oil conservator and protects the 2-AGAINST POTENTIAL OIL LEAKAGES
transformer against the following conditions: IN THE TRANSFORMER
1-Against gas accumulations in the transformer, As mentioned in item 1, when oil leakages that occur in the
2-Against potential oil leakages in the transformer, transformer are more than 100 cm3, 300 cm3 and 400 cm3 the
3-Against oil surge which can occur during overheating contact system connected to upper oat activates, the reed switch
situations caused by failures in transformers. connected to the second oat system in the Buchholz Relay
activates and sends a signal. This signal means that the oil
1-AGAINST GAS ACCUMULATIONS IN THE leakage in the transformer reached to critical level and there is
TRANSFORMER not enounh oil in the oil conservator to protect the transformer.
Two oat systems exist in the Buchholz Relay. These two oat Therefore this contact is called the trip contact.
systems activate dry type Reed switches connected to them. The This is the contact used to deactivate the transformer.This
oat system which is at the Buchholz Relays upper side contact working in connection to the lower oat can be used as
activates the alarm reed switch. In case between 100 cm3 and one or two or can be preferred as changeover reed switch as well.
300 cm3 or 400 cm3 amounts accumulate in the Buchholz Relay,
or in case of an oil leakage with these amounts, the alarm switch is
activated and sends a signal. As this alarm reed switch can be used SAMPLE TAP
as one normal open or two normal open, one switch can be used There is the sample tap over the Buchholz Relay. This tap allows
as changeover as well. taking oil from within the transformer and degassing the gasses
accumulated in the relay as well. The tap is manufactured with
glob valve principle in order to prevent gas leakage.

3-OIL SURGE WHICH CAN OCCUR DURING


CONTROL-TEST BUTTON
OVERHEATING SITUATIONS CAUSED
Used to test if the contacts are working properly by moving the
BY TRANSFORMER FAILURES
upper and lower oats in the Buchholz Relay up and down.
In case of overhating situations caused by transformer failures,
Additionally, when the lower oat is activated because of the oil
if the oil ow rate (table-1) in the Buchholz Relay exceeds the
ow rate, the signal doesnt disappear from the system unless the
specied values, the lower oat system described in item two is
system is reset by the test button.The systems are reset and the
activated and sends a signal. This signal (trip) is also used to
signal disappears when the test button is pressed.
deactivate the transformer.

MATERIAL
Buchholz Relay casing, cover, terminal box cover, glass frame cover
are produced from aluminum material and coated with electrostatic Table1 - STEADY OIL FLOW FOR THE RELAY TO WORK m/s
powder paint. The glasses on the relay are produced from tempered
glass to make them stronger against breakage. Markings and OIL TUBE STEADY OIL
graduations on the glass are written with special ring technique. CONNECTION FLOW FOR THE TOLERANCE
INNER DIAMETER mm RELAY TO WORK m/s
MOUNTING THE BUCHHOLZ RELAY TO THE TRANSFORMER 25 1 15
Buchholz Relay is intended to work in a horizontal positions. it is
connected with a 5 positive angle to the horizontal axis with the 50 1 15
arrow mark on the relay pointing to the oil conservator.
Buchholz Relays are manufactured to allow both thread and ange 80 1-1,5 15
connections.
Thread connections types for ange connections are also shown
in (Table 1). SEPARATION AND CLOSING CAPACITY

WORKING PRESSURE VOLTAGE CURRENT SEPARATION CAPACITY


Buchholz Relay is tested for an inner pressure of 50 kPA. In addition
to that, it is tested with an extreme pressure of 250 kPA for 2 minutes.
48V-127V d.c 2A 250W L/R <40ms
MAGNETIC FIELD RESISTANCE
Buchholz Relays operate perfectly up to 25m T magnetic elds 230V a.c 2A 400VA Cos c >0.5
Additionally, they are resistant to any d.c. eld value at any drection
TERMINAL BOX
and polarization.
In the terminal box, there is 1 earthing terminal and depending on the
number of contacts there are 4 to 10 electric terminals.
WORKING CURRENTS
These electric terminals allow connection of cables with 1,5 and 4mm 2
The working current is 2A. r.m.s and 30ms, The short circuit current
cross sections. PG16 or M20X1,5 cable gland can be used for cable
is 10A. r.m.s.
entry. Connection diagram of the electric terminals is shown on the
electric terminal cover.

2
BUCHHOLZ RELAYS
AN 50216-2

Terminal box cover

Electric terminal
connection scheme
Cable coupling
Earthing screw (PG16 or M20x1,5)
Blind plug
Electric terminal
Control-Test Button
Terminal box
Upper Reed Switch Upper Float
Sample tap
Lower Float
Control-test button
Flow Speed Control
Element
Product label area
Lower Reed Switch
Connection Hanger

Strong and specially


gradualed inspection glass.

Thread (B) and ange (A) connection types.

Inspection sight glass cover.

Figure A: casing with ange connection Figure B: casing with thread connection

3
BUCHHOLZ RELAYS
AN 50216-2

91 178.5
28

65
125

G1A

223
88

25
R92

18
67

166
185
351

Transformer
Type No Type No Nom.Pipesize Weight Power
Connection
DIN CODE DIN CODE (mm.) D1 (kg.) Class
ABR25-V50 Screwed
741 (DG-25) 25 3,9 5000 KVA
G 1A
(AN50216-2)

4
BUCHHOLZ RELAYS
AN 50216-2

200

115
68
91 178.5
28

65
125

223
88

14
85
R92
25
67

16
166

351

Transformer
Type No Type No Nom.Pipesize Weight Power
Connection
DIN CODE DIN CODE (mm.) D1 (kg.) Class
ABR25-F50
751 (DR-25) FLANGED 25 4,7 5000 KVA
(AN50216-2)

5
BUCHHOLZ RELAYS
AN 50216-2

195

102

165
91 178.5
28

68
112.5

75.5

226

125
90

50 R92
82.5

8
1

18 166

351

Transformer
Type No Type No Nom.Pipesize Weight Power
Connection
DIN CODE DIN CODE (mm.) D1 (kg.) Class
ABR50-F100
761 (DR-50) 5,8 5000 KVA
FLANGED 50 10000 KVA
(AN50216-2)

6
BUCHHOLZ RELAYS
AN 50216-2

195

138
200
178.5
28

65
97.5

M16

60
60.5

1
229

0 R92
8
100

8
1

18 166
351

Transformer
Type No Type No Nom.Pipesize Weight Power
Connection
DIN CODE DIN CODE (mm.) D1 (kg.) Class
ABR80-F100
771 (DR-80) FLANGED 80 6,5 10000 KVA
(DIN 42566)

7
BUCHHOLZ RELAYS
AN 50216-2

NORMALLY OPEN CONTACT

01 02 03 04
(Lover oat) (Lover oat) (2 Normally Open Contact) (2 Changeover Open Contact)
(Single Contact) (Single Contact) 1 Normally Open Contact Lower 1 Changeover Open Contact Lower
1 Normally Open Contact 1 Changeover Contact 1 Normally Open Contact Upper 1 Changeover Open Contact Upper
Yellow Yellow Yellow Red Yellow Red
11 12 14 11 12 11 12 21 22 14 11 12 24 21 22

Lower Lower Lower Upper Lower Upper

05 (4 Normally Open Contact) 06 (4 Changeover Open Contact)


2 Normally Open Contact Lower 2 Normally Open Contact Lower
2 Normally Open Contact Upper 2 Changeover Open Contact Upper

Yellow Blue Red Green Yellow Blue Red Green


11 12 31 32 21 22 41 42 11 12 31 32 24 21 22 34 31 32

Lower Lower Upper Upper Lower Lower Upper Upper

8
BUCHHOLZ RELAYS
AN 50216-2

NORMALLY CLOSED CONTACT

07 08
(Lover oat) (2 Normally Closed Contact)
(Single Contact) 1 Normally Closed Contact Lower
1 Normally Closed Contact 1 Normally Closed Contact Upper
Yellow Yellow Red
11 12 11 12 21 22

Lower Lower Upper

09 (4 Normally Closed Contact) 10 (4 Contact)


2 Normally Closed Contact Lower 2 Normally Closed Contact Lower
2 Normally Closed Contact Upper 2 Changeover Closed Contact Upper

Yellow Blue Red Green Yellow Blue Red Green


11 12 31 32 21 22 41 42 11 12 31 32 24 21 22 34 31 32

Lower Lower Upper Upper Lower Lower Upper Upper

9
BUCHHOLZ RELAYS
AN 50216-2

Control-Test Button
Sample Tap

Control - Test Button

Contact Locking Magnet

Float Seating
Oil Speed Control Element

Buchholz Relay Sectional Views

10
BUCHHOLZ RELAYS
AN 50216-2
TECHNICAL DATA

PARAMETER DATA NOTES

Nominal voltage AC 230V 12 V to 250 V


DC 230V 12 V to 250 V

AC 230V 12 V to 250 V
Nominal current
DC 230V 12 V to 250 V

Contact voltage capacity AC 1000 V -

Insulation voltage capacity AC 2000 V Contact against casing

Temperature range:

-ambient temperature (-40C to +55C)-(40F to +131F) Climate acc. to DIN EN 60068-2-78:2002-09

-working range:

(*temperature of the insulation uid) (-40C to +155C)-(-40F to +239F) Others on request

(*viscosity of the insulation uid) <1100 mm/s

Shock resistance class 4M6

-Earthquake / Vibration 2g(peak value) frequency range 2Hz to 200 Hz -


-Impact 25g/shocl duration 11 ms -

Resistance to pressure 0.25 MPa -

Resistance to vacuum <2.5 kPa -

Insensitivity to magnetic elds 25mT -

Switching system:

-Number or switching contacts per switching system 1 More on request

-Switching contact magnet contact tube -

-Flow speed control element hold by magnets -

-Response time of speed control element <0.1s -

Response of switching system in case of:


-Gas accumulation 200 cm to 300 cm -

-Flow of insulation uid

nominal diamenter (DN) 25 mm 1.00 m/s+15% -

nominal diamenter (DN) 50 mm 1.00 m/s+15% -

nominal diamenter (DN) 80 mm 1.00 m/s+15% or 1.50 m/s+15% or 2.00 m/s+15% -

Cable gland M20x1.5 Others on request

Nominal installation position 1 accending towards expansion vessel 0 to 5


Degree of protection IP54 Others on request