Sie sind auf Seite 1von 1

GENERAL NOTES

1. ALL DIMENSIONS ARE IN mm & ALL LEVELS ARE IN m.

7 5 4 3 2
11

CWT822J
TOTO

REFERENCE DRAWINGS
REV. REV.
CWT822J(T1)
TOTO

DESIGN DRAWING NO SHOP DRAWING NO


NO NO
ATR-DT3-DWG-2000-1 R0
ATR-DT3-DWG-2003-1 R0

ATR-DT3-DWG-2006-1 R0
ATR-DT3-DWG-2009-1 R0
FT ATR-CKR-EL-DWG-0008 R3
CWT822J(T1)

PAY1780E
CWT822J

TOTO
TOTO

TOTO

ATR-CKR-FA-DWG-0302 R2

ATR-DT3-AR-DWG-3020 R1

DW
TOTO
CWT822J

TOTO
CWT822J(T1)

DW
WH
WM

REF

PAY1780E
TOTO

TOTO
CWT822J

TOTO
CWT822J(T1)

PROJECT

COLOMBO RESIDENTIAL TOWER


COLOMBO, SRI LANKA
VOID VOID
CLIENT
ELEV A2 ELEV A3 ELEV A4 INDOCEAN DEVELOPERS (PVT) LIMITED
EXTRACT DUCT

FI

DESIGN ARCHITECT
SAFDIE ARCHITECTS, LLC.
100 PROPERZIE WAY
UP
SOMERVILLE, MA 02143-3740 USA
SP T 617.629.2100 F 617.629.2406
SP SP
ASSOCIATE ARCHITECT
DN
14 DESIGN TEAM 3
SINGAPORE
T 658.499.7168
FT
STRUCTURAL ENGINEER
MR. PREDRAG EROR
14
20
19

18

17

16

15

13

12

11

P.O. BOX 102803, DUBAI, UAE


10

ELEV A1 T 9714.3629234 F 9174.3629234


VOID VOID
09
01

02

03

04

05

06

07

08

SP
MECH, ELECT, PLUMBING ENGINEER
CKR CONSULTING ENGINEERS PVT. LTD.
PO BOX 73889
DUBAI, UAE
T +97143384277
FIRE ALARM SOUNDER & STROBE LANDSCAPE ARCHITECT
P LANDSCALE CO., LTD.
TOTO
CWT822J(T1)

59/3 SOI SUKHUMVIT 39 SUKHUMVIT ROAD, KLONGTON NUA

REF
PAY1780E
TOTO

WATTANA, BANGKOK 10110 T. 662.261.3700.9


TOTO
CWT822J

LOCAL STRUCTURAL ENGINEER & SUPERVISION CONSULTANT


DEEPAL WICKREMASINGHE ASSOCIATES
TOTO
NO. 377/2, Thalawathugoda Road, Hokandara South, Sri Lanka.
T- +94 11 4402395
CWT822J(T1)

DW
TOTO
CWT822J

ISSUE
NO. DESCRIPTION DATE
00 FOR APPROVAL 19.04.2016
SP SP 01
02
CWT822J(T1)

CWT822J

PAY1780E
TOTO

TOTO

TOTO

03
04
05
CO-0RDINATION CERTIFICATE
S. NO DISCIPLINE DATE SIGNATURE

DETAIL-01 1.
2.
3.
4.
5.
6.
KEY PLAN

H F D B

G E C A

ALTAIR
Indocean Developers (Pvt) Ltd Main Contractor
No: 121A, Sir James Peiris Mawatha
Colombo 02
Approved
Approved as Corrected
Submit Specified Item
Revise and Resubmit
Rejected Sub Contractor
MAXAIRE (PVT) LTD
110 , Isipathana Mawatha,
Colombo 05.
The review is only for general conformance T : +94 11 2501370, 2501305, 4641477
with the design concept of the project and F : +094 11 2589860
general compliance with the information given E : info@maxaire.net

in the Contract Documents. Contractor is


responsible for: Dimensions to be confirmed DISCIPLINE FIRE DETECTION
and correlated at the job site; information that
pertains solely to the fabrication processes or
to the means, methods, techniques, DRAWING TITLE
sequences, and the procedures of INCLINED TOWER LEVEL - 11
constructions; coordination of the Work of all
trades; and for performing all work in a safe FIRE DETECTION ,FIRE ALARM &
and satisfactory manner. VOICE EVACUATION CONDUIT LAYOUT
Any approval from the Engineer/Consultant of
submittals, materials and workmanship etc. Detailed Drawn Checked Approved Scale Size
shall not relieve the Contractor of his sole
responsibility and obligation to comply with 1:100
all requirements under the Contract. Premasiri
Isuru Mahesh Isuru A1
Date Date Date Date
Consultant/Engineer
19.04.2016 19.04.2016 19.04.2016 19.04.2016
Reviewer Drawing Number Rev.
Signature Date
ATR-SPLL(MAX)-FA-DWG-IT-L13-0572 0
Status
SHOP DRAWING