Continued From PG 1 and venting is still not an indus- vice and see how many have rust
try recommendation. Therefore, on the burners, heat exchanger,
on the job and tested. Nothing appliances. its easy to understand why no or flue. If you see the rust, that
can be pre-set at the factory to one wants us to adjust fuel since equipment has venting prob-
address all field applications. A force is needed to draw air into there is no guarantee of air to mix lems and possibly combustion
the burner. This force is draft. with it. air problems. Remember, fuel is
Fuel and air both need to be con- Most think of draft as the force regulated 100% of the time so it
trolled in all cases and possibly that removes flue gases from A common assumption made makes sense to regulate air. This
adjusted to maximize equipment equipment. True enough. But it is if you have draft, you have would require us to control draft
safety and efficiency. This should also draws in combustion air. proper combustion air and which is constantly changing.
appear to be a logical approach to
the combustion process; however, How is draft produced? In nor-
according to many industry stan- mal flues, draft is created by com-
dards, this is not the case. Fuel is municating the inside flue tem-
controlled but rarely allowed to perature and mechanical room
be adjusted and air is ignored all pressure to outside temperature
together! and barometric pressure. The flue
is the device that connects them
Why Are We Ignoring Air? to each other. The exception
would be draft that is created by
If you dont control air, dont inducers on most newer condens-
adjust the fuel! To do so would ing equipment. Outside tem-
be reckless and dangerous. This perature and pressure constantly Tom - Performing a CO Analysis
brings up the question, why are vary and affect draft. Therefore,
we ignoring air? draft is a variable that needs to be venting. Or if your air proving
controlled or there is no control pressure switches are made, you There are millions of accidents
According to code, providing of combustion air and venting. are proving proper combustion just waiting to happen if they are
openings in a wall or ceiling will air and venting. This is incorrect! not already happening. The plac-
deliver necessary combustion For draft to control combustion Only proper combustion testing es they will occur are pre-exist-
air. However, an ASHRAE study air and venting, the flue must be and diagnostics can guarantee ing. There are the select few who
in 2000 concluded that code-ap- connected to the appliance, not adequate combustion air and cor- choose to step forward into the
proved combustion air does not just in the vicinity. Unfortunate- rect venting. Does this seem like 21st century of combustion diag-
provide adequate combustion air. ly, not every piece of drafthood something the HVAC industry nostics, while the rest are satisfied
There are too many forces in a equipment is connected to a flue. should address or just continue with the 17th century theories."
building competing for that air, to ignore?
whether it is building leakage, Currently, controlling residential Jim Davis - The National Com-
duct leakage, or other exhausting or commercial combustion air Look at the equipment you ser- fort Institute
2 info@CorcoranHeating.com
24/7 Emergency Service: (847) 397-5888
C ooking Corn e r :
Halloween Popcorn Balls
1st vs Reds 2:20
th
6 @ Na onals TBD
In the Halloween DIY spirit? Heres a stencil to make your pumpkin carving more enjoyable 15th @ Ravens Noon
this year. Simply cut out, tape to your pumpkin, and cut out the black areas. 22nd
vs Panthers Noon
CorcoranHeating.com 3
2137 Hammond Dr.,
Schaumburg, IL 60173
info@corcoranheating.com
CorcoranHeating.com
(847) 397-5888
Cozy Newsletter
CorcoranHeating.com 24/7 Emergency Service: (847) 397-5888