Beruflich Dokumente
Kultur Dokumente
100m
5m
C2A H0D
FRESH WATER
7130-WF-1816-C2A-12"-N 7130-WF-1666-H0D-12"-N
BU-2200G AV-9415
4785 5100-25J-010
5150-WF-1959-T2H-8"-N
8" BU-2200G AV-9412
4m
TANK T-59
T2H 3
LO
A
LO
LO
LO
LO
BU-2200G
LO
T2L T2K T2K T2L T2L T2H T2H T2K T2K T2H T2H T2K T2H T2K T2H T2H T2K
3m
T2K T2H NOTE 2
FRESH WATER 5150-WF-1820-T2L-36"-N 5150-WF-1922-T2K-36"-N 5150-WF-1923-T2L-36"-N 5150-WF-1924-T2H-36"-N 5150-WF-1925-T2K-36"-N 5150-WF-1926-T2H-36"-N 5150-WF-1927-T2K-36"-N T2K 5150-WF-1928-T2H-36"-N 5150-WF-1929-T2K-36"-N 5150-WF-1821-T2H-36"-N
50m
5392 5100-25J-006
PUMP STATION NO. 4B PHASE 2 PHASE 1
2m
3
DRAIN
BU-2200G AV-9418
AV-9417
5150-WF-1936-T2H-10"-N
5150-WF-1935-T2H-8"-N
FRESH WATER 7130-WF-1669-H0D-12"-N 7130-WF-1669-H0D-12"-N 7130-WF-1817-C2A-12"-N
5384 5100-25J-010
6" GA-2200
1m
12"x8" BU-2200G
ELECTROWINNING STORAGE BU-2200G
LO
LO
LO
TANK T-59 NOTE 1
AV-9419
T2H
8" BU-2200G
3 T2K T2H 3 T2H T2K T2K T2H T2H
0
T2H T2K
0
LO
1:50
5150-WF-1933-T2K-36"-N T2K T2K
1:1000
3m
3
B
50m
4" GA-2200
5150-WF-2027-T1M-6"-N
5150-WF-2028-T1M-6"-N
4" GA-2200
AV-9420
AV-9421
AV-9422
AV-9423
AV-9424
DRAIN DRAIN AV-9425
40m
DRAIN
2m
5150-WF-1948-T2K-36"-N
BU-2100G
BU-2100G
8" BU-2200G
8" BU-2200G
8" BU-2100G
6" BU-2100G
DRAIN
3" GA-2200
4" GA-2200
LO
LO
LO
LO
LO
LO
T2K T2H T2H T2K T2K T2H T2H T2K T2K T2H T2H T2K T2K T2H T2H T2K BY CIVIL BY PIPING
NOTE 2 T2K T1M T1M H0C T1M H0C C1A
H0C H0C H0C H0C T1M
30m
CS 3
5150-WF-1942-T2H-36"-N 5150-WF-1944-T2K-36"-N 5150-WF-1945-T2H-36"-N 5150-WF-1946-T2K-36"-N 5150-WF-1949-T2H-36"-N 5150-WF-2026-T2K-36"-N 5150-WF-1066-T1M-36"-N 3 H0C 5150-WF-1950-H0C-36"-N HDPE CS HDPE
C1A 5150-WF-1640-C1A-36"-N FRESH WATER
5383 5100-25J-013
1m
H0C C2-5160-TK-740
5150-WF-1947-T2H-36"-N
H0C
GA-1155
GA-1155
GA-1155
20m
BU-2200G
5150-WF-1952-T1K-3"-N
T2H T1K
4" GA-2200
4" GA-2200
H0D
TP-7130-123 3
BU-1010G
T2H C2A
10m
BU-2200G
BY CIVIL
0
3 NOTE 1
AV-9443
T1D BY PIPING
GA-1155
1:33 1/3
DRAIN DRAIN
C
0
2" BA-2000
1:500
LO
DRAIN
2.5m
7130-WF-1679-H0D-12"-N FRESH WATER
20m
5388 5100-25J-011
C2-7130-TK-901
2m
15m
1.5m
5150-WF-1838-T1K-8"-N
FRESH WATER TO DUST CONTROL AND CONTRACTOR OFFICES
10m
1m
D
5m
0.5m
FRESH WATER
5150-WF-1678-T1K-8"-N
5390 5100-25J-011
POTABLE WATER TREATMENT
PLANT
0
K141
0
1:25
PHASE 1 BY OTHERS
BY CIVIL
1:200
7130-WF-1686-T1K-8"-N BATCH
PLANT
2m
10m
C2A T2J
1.5m
5100-25J-011 5389
TEMPORARY PUMPING
STATION
AV-9441
E
1m
2" BA-2000
5m
LO
T1D H0D
0.5m
4782 5100-25J-011
NOTES: TEMPORARY PUMPING
NOTE 1 1. TEMPORARY PIPING SPOOL TO BE REMOVED WHEN THE CONSTRUCTION WATER STATION
SYSTEM IS DECOMMISSIONED, A BLIND FLANGE SHALL BE INSTALLED IN THE MAIN
LINE BRANCH.
2. PADDLE BLIND TOBE INSTALLED DURING OPERATION OF CONSTRUCTION WATER HOLDS:
SYSTEM AND SHALL BE CHANGED TO A PADDLE SPACER WHEN THE FRESH WATER 1. DELETED. 3
0
SUPPLY SYSTEM BEGINS TO OPERATE. DESIGN OF PADDLE BLIND AND PADDLE SPACER
BY CONTRACTOR ACCORDING TO ASME CODE B16.48 ISSUED FOR DETAILED ENGINEERING PHASE ENGLISH LANGUAGE SHALL GOVERN
0
1:20
EMITIDO PARA INGENIERIA DE DETALLE LA LENGUA INGLESA TENDRA PRECEDENCIA
DESIGNED BY DRAWN BY
1:100
sociedad minera
DES. DES.
REV. DATE REVISION DESCRIPTION
CHK.
APPROVED REV. DATE REVISION DESCRIPTION
CHK.
APPROVED REFERENCE DRAWING No. REFERENCE DRAWINGS
G. CESPEDES A. REGNAULT TEMPORARY CONSTRUCTION EQUIP. & TOOLS
A
NOT USED
2 10-Mar-14 ISSUED FOR CONSTRUCTION DWG FOR COMBINED SQUAD CHECK
GC LT cerro verde s.a.a. CHECK DESIGN CHECK DRAWING
FRESH / CONSTRUCTION WATER
AREQUIPA - PERU V. UDUMAN
B NOT USED 3 20-Mar-14
RE-ISSUED FOR CONSTRUCTION GC LT LEAD ENGINEER APPROVAL DATE PIPING AND INSTRUMENTATION DIAGRAM
SES KFC CERRO VERDE PRODUCTION UNIT EXPANSION
NOTE USED
Cerro Verde L. TAMELIN 12/4/2013
SISTEMA DE AGUA FRESCA
F
ISSUED FOR DESIGN GC AJ PROPERTY OF FLUOR AND IS LENT TO THE BORROWER FOR THEIR N/A AGUA FRESCA / DE CONSTRUCCION
0 10-Dec-12 CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF THE LOAN OF THIS
BA FF ENGINEERING MANAGER APPROVAL DATE
CONTRACT NO.
RE-ISSUED FOR DESIGN (2013 ESTIMATE) GC AG DRAWING, THE BORROWER PROMISES AND AGREES TO RETURN IT UPON DIAGRAMA DE TUBERIAS E INSTRUMENTACION
0A 21-May-13 REQUEST AND AGREES THAT IT WILL NOT BE REPRODUCED, COPIED LENT K. MUNDY 12/5/2013
VU R
OR OTHERWISE DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR CLIENT APPROVAL DATE SCALE DRAWING NUMBER REV.
GC LT
1H 04-Dec-13 ISSUED FOR COSNTRUCTION
VU KM
ANY OTHER PURPOSE OTHER THAN WHICH IT IS FURNISHED. J. VANDERBEEK 12/5/2013 NONE 240K-C2-5100-25J-018 3
MANUAL CHANGES MADE: YES NO DWG. FILE UPDATED: YES NO MODEL UPDATED: YES NO CAD FILE NAME: P:\0CAD\000\SPEM\** WBS: 7130
BA6CVA1.IGR
SAFETY SHARE: BE ALERT! DON'T GET HURT COMPARTAMOS LA SEGURIDAD: SIEMPRE ALERTA! NO SE LASTIME
Apr 2012