Sie sind auf Seite 1von 6

Heater

Name EXCHANGE
Property method PENG-ROB
Henry's component list ID
Electrolyte chemistry ID
Use true species approach for electrolytes YES
Free-water phase properties method STEAM-TA
Water solubility method 3
Specified pressure [N/sqm] 1500000
Specified temperature [K] 298
Specified vapor fraction
Specified heat duty [Watt]
EO Model components
Calculated pressure [N/sqm] 1500000
Calculated temperature [K] 298
Calculated vapor fraction 0
Calculated heat duty [Watt] -250.934298
Temperature change [K]
Degrees of superheating [K]
Degrees of subcooling [K]
Pressure-drop correlation parameter
Net duty [Watt] -250.934298
First liquid / total liquid 1
Total feed stream CO2e flow [kg/sec] 0
Total product stream CO2e flow [kg/sec] 0
Net stream CO2e production [kg/sec] 0
Utility CO2e production [kg/sec] 0
Total CO2e production [kg/sec] 0
Utility usage
Utility cost
Utility ID
Flash2
Name FLASH
Property method PENG-ROB
Henry's component list ID
Electrolyte chemistry ID
Use true species approach for electrolytes YES
Free-water phase properties method STEAM-TA
Water solubility method 3
Temperature [K]
Pressure [N/sqm] 100000
Specified vapor fraction
Specified heat duty [Watt] 0
EO Model components
Outlet temperature [K] 230.61195
Outlet pressure [N/sqm] 100000
Vapor fraction 0.391587369
Heat duty [Watt] 0
Net duty [Watt] 0
First liquid / total liquid 1
Total feed stream CO2e flow [kg/sec] 0
Total product stream CO2e flow [kg/sec] 0
Net stream CO2e production [kg/sec] 0
Utility CO2e production [kg/sec] 0
Total CO2e production [kg/sec] 0
Utility usage
Utility cost
Utility ID
Compr
Name COMPRESS
Property method PENG-ROB
Henry's component list ID
Electrolyte chemistry ID
Use true species approach for electrolytes YES
Free-water phase properties method STEAM-TA
Water solubility method 3
Model Type
Specified discharge pressure [N/sqm] 1500000
Specified pressure increase [N/sqm]
Specified pressure ratio
Specified power required [Watt]
Isentropic efficiency 1
Mechanical efficiency
Polytropic efficiency
EO Model components
Indicated horsepower [Watt] 103.754528
Calculated brake horsepower [Watt] 103.754528
Net work required [Watt] 103.754528
Power loss [Watt] 0
Efficiency (polytropic / isentropic) used 0.72
Calculated discharge pressure [N/sqm] 1500000
Calculated pressure change [N/sqm] 1400000
Calculated pressure ratio 15
Outlet temperature [K] 407.283102
Isentropic outlet temperature [K] 373.932285
Vapor fraction 1
Displacement
Volumetric efficiency
Head developed [J/kg] 163621.466
Isentropic power requirement [Watt] 69.9857981
Inlet heat capacity ratio 1.14595656
Inlet volumetric flow rate [cum/sec] 0.000229787
Outlet volumetric flow rate [cum/sec] 2.09458E-05
Inlet compressibility factor 0.978858616
Outlet compressibility factor 0.896127262
Compressor percent above surge
Percent below stonewall
Surge volume flow rate
Stonewall volume flow rate
Shaft speed
Specific speed
Inlet Mach number
Total feed stream CO2e flow [kg/sec] 0
Total product stream CO2e flow [kg/sec] 0
Net stream CO2e production [kg/sec] 0
Utility CO2e production [kg/sec] 0
Total CO2e production [kg/sec] 0
Utility usage
Utility cost
Utility ID
Valve
Name VALVULA
Property method PENG-ROB
Henry's component list ID
Electrolyte chemistry ID
Use true species approach for electrolytes YES
Free-water phase properties method STEAM-TA
Water solubility method 3
Specified outlet pressure [N/sqm] 100000
Specified pressure drop [N/sqm]
Valve operating specification: % operating
Valve operating specification: flow coef
Cv at 100% opening
Valve pressure drop ratio factor
Valve pressure recovery factor
Valve inlet diameter [meter]
Calculation type ADIAB-FLASH
Valve pressure specification (design mode) P-OUT
EO Model components
Valve pressure specification (rating mode) VAL-POSN
Calculated outlet pressure [N/sqm] 100000
Calculated pressure drop [N/sqm] 1400000
Calculated valve % operating
Checked outlet pressure
Cavitation index
Pressure drop ratio factor
Pressure recovery factor
Piping geometry factor 1
Total feed stream CO2e flow [kg/sec] 0
Total product stream CO2e flow [kg/sec] 0
Net stream CO2e production [kg/sec] 0
Mixer
Name MIXER
Property method PENG-ROB
Henry's component list ID
Electrolyte chemistry ID
Use true species approach for electrolytes YES
Free-water phase properties method STEAM-TA
Water solubility method 3
Specified pressure [N/sqm] 100000
Temperature estimate [K]
EO Model components
Outlet temperature [K] 272.698353
Calculated outlet pressure [N/sqm] 100000
Vapor fraction 1
First liquid /Total liquid 1
Total feed stream CO2e flow [kg/sec] 0
Total product stream CO2e flow [kg/sec] 0
Net stream CO2e production [kg/sec] 0

Das könnte Ihnen auch gefallen