touch-screen area.
Battery Fault 7 8 9
PQRS TUV WXYZ
Power
* 0 #
Trouble
Signal Silence
Bypassed
Supervisory
Modular Structure
IN
E OUT
requirements
A
L 5. Power supply
Batteries
+ - - + - + + - - + - +
NO1
NO2
NC1
NC2
+ - a -b + + - a -b +
C1
C2
ZONE4
Strung
ZONE3
CZM0004A
RMH0002A
Strung
ANI0016A
F1 F2
ZONE1 RELAIS1
Strung Strung
Denmark DANAK 232.234 FPA 5000/1200 system certi- Alarm counters (external, internal, testing) 3
fikat EN54-13
Entries in the event database 10000
Czech Repub- TZS 080-011414 FPA-5000
lic FSP-5000-RPS configuration interfaces (USB, 2
COM)
Hungary TMT TMT-32/2005 FPA-5000
Ukraine MOE UA1.016.0008784-11 FPA-5000 Maximum number of outputs (sounders, 508
controls, etc.) activated in parallel due to the
MOE UA1.016.0137711-13 FPA-5000 same event
Singapore PSB CLS1B 13068137901 FPA-5000
Configuration limits per fire panel (FSP-5000- Max. number
Installation/configuration notes RPS)
System Limits Functional Modules Sufficient space should be left underneath and next
to the control panel for any possible extensions, e.g.
Functional module Max. number for an additional power supply or an extension
housing.
BCM-0000-B 8
Do not operate devices showing condensation.
ANI 0016 A 32 Only use the mounting materials specified by
BOSCH ST. Interference resistance cannot otherwise
LSN 0300 A 32 be guaranteed.
If connected to a Building Management System (BIS
LSN 1500 A 11
Bosch Building Integration System) via the Ethernet
FPE-5000-UGM 4 and an OPC server, please verify with the responsible
network administrator that in case of a network
CZM 0004 A 32 spanning multiple buildings:
the network is designed for connections across
IOS 0020 A 4 multiple buildings (e.g. no interference by
different potentials of the ground connection)
IOS 0232 A 4
all users are assigned to the network
ENO 0000 B 8
Technical specifications
IOP 0008 A 32
General System Limits
RML 0008 A 32
Max. number
RMH 0002 A 32
Panels/remote keypads/OPC server in the
NZM 0002 A 8 network
System Limits for each LSN 0300 A Module Ethernet / CAN loop 32
Up to 254 LSN improved version elements or 127
classic LSN elements can be connected CAN bus 8
Output current LSN elements
LSN 0300 A: up to 300 mA
LSN 1500 A: up to 1500 mA Stand-alone panel 4096
Cable length
LSN 0300 A: up to 1600 m Per network panel 2048
LSN 1500 A: up to 3000 m
Total network 32768
Unshielded cables can be used
Ordering information
Notice
Owing to the Planning Software by Bosch, the BCM0000B Battery Controller Module
planning of fire panels in compliance with the monitors the power supply of the fire panel and the
limits (e.g. concerning cable length and power charging of the batteries
supply) is quick and easy. Order number BCM-0000-B
Represented by: