PRELIMINARY
Title page
Alcatel-Lucent 9944
Smart Base Station S18K Rehosting | UA08.1
Technical Description
9YZ-03450-4201-DEZZA
Issue 0.04 | January 2013
PRELIMINARY
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Use pursuant to applicable agreements
Legal notice
PRELIMINARY
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2013 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
PRELIMINARY
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Contents
PRELIMINARY
About this document
Purpose .......................................................................................................................................................................................... xiii
xiii
2 UTRAN introduction
....................................................................................................................................................................................................................................
9944 Smart S18K features and functions ......................................................................................................................... 3-4
3-4
Rack User Commissioning module (RUC for d2U (V2/V3)) ................................................................................ 4-36
4-36
Physical characteristics of the 9944 Smart S18K digital modules ....................................................................... 4-38
4-38
Physical characteristics of the 9944 Smart S18K radio modules ......................................................................... 4-53
4-53
....................................................................................................................................................................................................................................
iv Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Multi-Carrier TRX900 (MC-TRX) .................................................................................................................................. 4-54
4-54
9944 Smart S18K cooling and heating system presentation .................................................................................. 4-78
4-78
Physical characteristics of the 9944 Smart S18K other equipment ..................................................................... 4-97
4-97
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary v
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY Contents
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
vi Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
List of tables
PRELIMINARY
1 Generic terms .............................................................................................................................................................. xiv
xiv
4-1 Digital modules supported by the 9944 Smart S18K ................................................................................. 4-12
4-8 Modules of the TRDU sub-rack - Dimensions and weight ...................................................................... 4-53
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary vii
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY List of tables
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
viii Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
List of figures
PRELIMINARY
1-1 Roadmap to Conventional Base Station documentation ............................................................................. 1-3
4-1 GSM and WCDMA 900 or 1800 hybrid configuration ............................................................................... 4-5
4-2 UMTS FDD band I (2100/1900 MHz band) configuration ....................................................................... 4-6
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary ix
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY List of figures
....................................................................................................................................................................................................................................
4-21 d2U air flow paths .................................................................................................................................................. 4-35
4-35
4-24 Front view of the TRDU sub-rack (fully equipped) ................................................................................... 4-42
4-34 9944 Smart S18K 1000 W or 1400W rectifier front panel ...................................................................... 4-64
PRELIMINARY
....................................................................................................................................................................................................................................
4-48 AISG RETA solution ............................................................................................................................................. 4-95
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary xi
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY List of figures
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
xii Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
PRELIMINARY
About this document
About this document
Purpose
This document describes the Alcatel-Lucent 9944 Smart Base Station S18K Rehosting
allowing a 2G BTS to re-host a hybrid 2G (GSM) and 3G (UMTS) Node B configuration.
The following short name is used in this publication: 9944 Smart S18K.
Intended audience
The audience for this document is Operations and Maintenance personnel, and anyone
interested in learning more about the 9944 Smart S18K.
PRELIMINARY
Supported systems
This document applies to Alcatel-Lucent W-CDMA UA08.1 system release.
...................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary xiii
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY About this document
....................................................................................................................................................................................................................................
How to use this document
No specific recommendation applies regarding the way readers should read this
document.
Prerequisites
It is recommended that the reader becomes familiar with:
Alcatel-Lucent 9100 BTS Hardware Description, 3BK 21642 AAAA TQZZA
9100 BTS/9110 Micro BTS Corrective Maintenance Handbook, 3BK 21643 AAAA
PCZZA
Conventions used
.
Vocabulary conventions
For a list of terms used in this document, see Alcatel-Lucent W-CDMA System -
Terminology, NN-20500-002.
This document uses some terms generically.
Typographical conventions
The following typographical convention is used in this document:
Appearance Description
Document reference, reference number Related document that is referenced in the document.
PRELIMINARY
....................................................................................................................................................................................................................................
xiv Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
About this document
PRELIMINARY
....................................................................................................................................................................................................................................
Related information
For information on subjects related to the content of this document, refer to the
documents listed in the following table:
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary xv
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY About this document
....................................................................................................................................................................................................................................
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-
lucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).
PRELIMINARY
....................................................................................................................................................................................................................................
xvi Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
PRELIMINARY
1 1oadmap to Conventional
R
Base Station
documentation
Overview
Purpose
This chapter provides the roadmap for Conventional Base Station documentation.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 1-1
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation
PRELIMINARY
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 1-3
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
1-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
PRELIMINARY
2 UTRAN introduction
2
Overview
Purpose
This chapter describes the Universal Mobile Telecommunications System (UMTS)
Terrestrial Radio Access Network (UTRAN).
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 2-1
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY UTRAN introduction UTRAN introduction
....................................................................................................................................................................................................................................
UTRAN introduction
UTRAN components
The UTRAN is composed of at least one Radio Network Subsystem (RNS). An RNS
covers a certain geographical area. It is equivalent to the GSM BSS. Each RNS is
composed of one Radio Network Controller (RNC) and one or more Node Bs. RNSs are
interconnected through the Iur interface of each RNC to form a network.
Alcatel-Lucent UTRAN
The Alcatel-Lucent UTRAN is based on the following components:
RNC
Node B
WMS for the OAM part
RNC
The Alcatel-Lucent RNC is 3GPP-compliant. It is based on the Multiservice Switch
platform.
RNC interfaces
The RNC provides the following interfaces:
Iub towards a Node B
Iu towards the Core Network
Iur towards another RNC
Iupc towards a Standalone A-GPS SMLC (SAS)
Node B
The Alcatel-Lucent Node Bs are 3GPP-compliant. The Alcatel-Lucent Node B portfolio
PRELIMINARY
includes:
Conventional unitary base stations
Digital base stations
Radio base stations
....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
UTRAN introduction UTRAN introduction
PRELIMINARY
....................................................................................................................................................................................................................................
Radio heads
Base station routers
Node B interfaces
The Node B provides the following interfaces:
Iub towards an RNC
Uu towards a UE
Interface B towards WMS
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 2-3
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY UTRAN introduction UTRAN introduction
....................................................................................................................................................................................................................................
WMS
PRELIMINARY
....................................................................................................................................................................................................................................
2-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
UTRAN introduction UTRAN introduction
PRELIMINARY
....................................................................................................................................................................................................................................
It plays an important role in providing the foundation of a complete end-to-end
management solution for UMTS networks. The WMS manages the entire UMTS
network, which is divided into:
The UTRAN
The Core Network (circuit-switched and packet-switched traffics).
The Access Network OAM manages the UTRAN part of the network.
NSP
The Network Services Platform (NSP) is a graphical user interface to the Access Network
providing a common platform for navigation and control. The NSP interfaces with the
NEs through a Common Object Request Broker Architecture (CORBA). This
vendor-independent architecture links computer applications across different networks.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 2-5
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY UTRAN introduction UTRAN introduction
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
2-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
PRELIMINARY
3 3944 Smart S18K basic
9
characteristics
Overview
Purpose
This chapter describes the basic characteristics of the 9944 Smart S18K.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 3-1
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K basic characteristics 9944 Smart S18K introduction
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K basic characteristics 9944 Smart S18K introduction
PRELIMINARY
....................................................................................................................................................................................................................................
The following figure shows the outside view of the 9944 Smart S18K cabinet.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 3-3
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K basic characteristics 9944 Smart S18K features and functions
....................................................................................................................................................................................................................................
procedures
Dedicated channel management, which includes setup, release, and modification
procedures
Cell management, which includes setup, deletion, and modification of a cell
Power control for controlling UE power emission
....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K basic characteristics 9944 Smart S18K features and functions
PRELIMINARY
....................................................................................................................................................................................................................................
Softer handover, in which a single base station manages the cells in communication
with the UE
Common Channels defense in case of CE (Channel Element) failure by relocating
them autonomously to available CE resources (same board or another) without
involvement of the RNC
Call processing is mapped on the Core Controller Module (CCM) and the Channel
Element Module (CEM). It supports multiple CEM. Multiple CEM (or multi-CEM)
allows to use several CEMs for call processing management. In the 9944 Smart S18K,
call processing is mapped on the xCCM-U/eCCM-U and xCEM-U/eCEM-U modules.
Performance monitoring
The performance monitoring function is in charge of collecting performance
measurement data from the network interface function and from the
configuration/supervision function.
The measurement data is used to calculate and report performance data to the RNC for
traffic control and to the WMS for network operation and tuning.
Network interface
This function is in charge of managing interfaces with RNC:
Physical layer management (configuration, alarm reporting)
Layer 2 (IMA, switching, etc.)
The 9944 Smart S18K supports the following types of transport on the Iub interface:
ATM
Hybrid ATM / IP
Native IP
Configuration/supervision
This function is in charge of:
Module configuration and supervision
Inventory information reporting
Plug-and-play management
The remote inventory functionality provides the UMTS OAM access to determine the
composition of the Node B. The remote inventory is performed by the CCM for the
PRELIMINARY
following modules:
xCEM-U/eCEM-U, with their number
TRDUs, with their number
Fan rack
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 3-5
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K basic characteristics 9944 Smart S18K features and functions
....................................................................................................................................................................................................................................
LPPCM
Power system modules (ACU, DDU, CBU, Rectifiers)
9944 Smart S18K cabinet
Synchronization
This function is in charge of retrieving highly stable radio frequency from either network
interface or optional GPS receiver.
The 9944 Smart S18K can be synchronized through the following means:
E1/T1 PCM link (standard mechanism)
The E1/T1 link used for synchronization does not carry any data traffic.
Local GPS receiver
In the GPS-based synchronization solution, the xCCM-U/eCCM-U module is
connected to a GPS smart antenna/receiver that provides GPS synchro source (Pulse
Per Second (PPS) synchro input from the antenna).
IEEE 1588v2 Precision Time Protocol (PTP)
The PTP-based synchronization solution relies on time servers connected to the Node
B through the Ethernet network.
Note: This synchronization mechanism only applies to native IP Node B.
Synchronous Ethernet
Note: This synchronization mechanism only applies to native IP Node B.
PRELIMINARY
....................................................................................................................................................................................................................................
3-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K basic characteristics 9944 Smart S18K external interfaces
PRELIMINARY
....................................................................................................................................................................................................................................
Network interface
The 9944 Smart S18K supports three modes of Iub transport for 3G operations:
ATM
All Iub traffic (OAM, NBAP signaling, R99, HSPA) is carried over ATM/E1(T1).
E1 link complies with ITU G703/G704. T1 link is based on ANSI standard.
The raw data rate between Node B and RNC can rise up to 15.872 Mbit/s (E1) or
12.288 Mbit/s (T1). Depending on the data flow, ATM AAL2 and AAL5 are used on
the above physical link through IMA. The IMA framing provides for physical link
performance monitoring and management.
In the case of a 120-ohm network, the only equipment needed to ensure the PCM
connection is the 120-ohm PCM cable.
In the case of a 75-ohm network, it is necessary to have baluns (two baluns per PCM)
to ensure adaptation from the 120 ohm of the Node B to the 75 ohm of the customer
network. Four types of baluns can be used: BNC, 1.6/5.6, SMZ type 43, or BNC to
RJ-45.
Hybrid ATM/IP
An IP-based Iub transport is used for HSPA traffic whereas an ATM-based Iub
transport is used for the remaining Iub traffic (R99, OAM and NBAP signaling). The
I/B HSPA traffic can also be carried on the ATM link if the IP link is lost (hybrid Iub
resiliency between ATM and IP).
The hybrid Iub interface requires an xCCM-U module (xCCM-U-4E1 or
xCCM-U-GE hardware configuration) or an eCCM-U module (eCCM-U 8-4E1
ports or eCCM-U-GE hardware configuration).
Native IP
With native IP Iub transport, you can choose to carry all Iub traffic (OAM, NBAP
signaling, R99, HSPA) on an IP over Ethernet transport.
The native Iub interface requires an xCCM-U module (xCCM-U-GE hardware
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 3-7
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K basic characteristics 9944 Smart S18K external interfaces
....................................................................................................................................................................................................................................
Radio interface
The radio interface consists of up to 12 RF ports (six in the basic configuration) which
correspond to the connection to main and diversity antennas for up to six sectors (three in
the basic configuration).
The impedance of the radio interface is 50 ohm.
Other equipment
The 9944 Smart S18K provides:
A 19-inch 1U space for the optional lightening protection module, above the d2U rack
A 19-inch 1U space for the alarm module, underneath the d2U rack
A space for one optional batteries string
A 19-inch 6U space for optional user modules, such as the Central Control Unit
(CCU) when AISG RETA option is required.
PRELIMINARY
....................................................................................................................................................................................................................................
3-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K basic characteristics 9944 Smart S18K optional features
PRELIMINARY
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 3-9
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K basic characteristics 9944 Smart S18K physical and environmental characteristics
....................................................................................................................................................................................................................................
Size
Width (W): 1350 mm
Depth (D): 735 mm
Height (H): 1500 mm
Weight
Cabinet - empty, pre-cabled : < 120 kg
Fully-equipped (with batteries) : < 450 kg
Environmental characteristics
The 9944 Smart S18K is designed to support
An external temperature range of -40C to +50C
An absolute humidity between 1 g/m3 and 36 g/m3
PRELIMINARY
....................................................................................................................................................................................................................................
3-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K basic characteristics 9944 Smart S18K configurations
PRELIMINARY
....................................................................................................................................................................................................................................
OTOR configuration
OTOR is the standard one-sector configuration. In this configuration, the Node B is
logically declared at the RNC as one cell. The OTOR configuration uses a single Power
Amplifier to transmit signals in all directions (Omni-directional).
According to the number of frequency carriers, the 9944 Smart S18K supports the
following configurations:
OTOR1
The OTOR1 configuration requires the following characteristics:
One antenna pair: two antenna ports (one TX/Rx Main and one Rx Div)
One frequency carrier
OTOR2
The OTOR2 configuration requires the following characteristics:
One antenna pair: two antenna ports (one TX/Rx Main and one Rx Div)
Two frequency carriers (adjacent or not)
OTOR3
The OTOR3 configuration requires the following characteristics:
One antenna pair: two antenna ports (one TX/Rx Main and one Rx Div)
Three frequency carriers (adjacent or not)
OTORx+y (x, y = 1 or 2)
These configurations require the following characteristics:
One antenna pair: two antenna ports (one TX/Rx Main and one TX/Rx Div)
Two to four frequency carriers: one or two frequency carriers (adjacent or not) in a
first operational bandwidth, and one or two other frequency carriers (adjacent or
not) in a second operational bandwidth
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 3-11
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K basic characteristics 9944 Smart S18K configurations
....................................................................................................................................................................................................................................
BTBR configuration
BTBR is the standard two-sector configuration. It is obtained from STSR configuration
and consists in doing an STSR depopulation. The Node B is logically declared at the
RNC as two cells. The power allocation with BTBR configuration is independent across
sectors.
According to the number of frequency carriers, the 9944 Smart S18K supports the
following configurations:
BTBR1
This configuration is an STSR1 configuration depopulation. It requires the following
characteristics:
Two antenna pairs: four antenna ports (one TX/Rx Main and one Rx Div per pair)
One frequency carrier
BTBR2
This configuration is an STSR2 configuration depopulation. It requires the following
characteristics:
Two antenna pairs: four antenna ports (one TX/Rx Main and one Rx Div per pair)
Two frequency carriers (adjacent or not)
BTBR3
This configuration is an STSR3 configuration depopulation. It requires the following
characteristics:
Two antenna pairs: four antenna ports (one TX/Rx Main and one Rx Div per pair)
Three frequency carriers (adjacent or not)
BTBRx+y (x, y = 1 or 2)
These configurations are an STSRx+y configuration depopulation. They require the
following characteristics:
Two antenna pairs: four antenna ports (one TX/Rx Main and one TX/Rx Div per
pair)
Two to four frequency carriers: one or two frequency carriers (adjacent or not) in a
first operational bandwidth, and one or two other frequency carriers (adjacent or
not) in a second operational bandwidth
STSR configuration
STSR is the standard three-sector configuration. The Node B is logically declared at the
RNC as three cells. Softer handover is controlled by the network.
PRELIMINARY
According to the number of frequency carriers, the 9944 Smart S18K supports the
following configurations:
STSR1
....................................................................................................................................................................................................................................
3-12 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K basic characteristics 9944 Smart S18K configurations
PRELIMINARY
....................................................................................................................................................................................................................................
This configuration is the smallest hardware configuration in STSR. It requires the
following characteristics:
Three antenna pairs: six antenna ports (one TX/Rx Main and one Rx Div per pair)
One frequency carrier
STSR2
This configuration requires the following characteristics:
Three antenna pairs: six antenna ports (one TX/Rx Main and one Rx Div per pair)
Two frequency carriers (adjacent or not)
STSR3
This configuration requires the following characteristics:
Three antenna pairs: six antenna ports (one TX/Rx Main and one Rx Div per pair)
Three frequency carriers (adjacent or not)
STSRx+y (x, y = 1 or 2)
These configurations require the following characteristics:
Three antenna pairs: six antenna ports (one TX/Rx Main and one Tx/Rx Div per
pair)
Two to four frequency carriers: one or two frequency carriers (adjacent or not) in a
first operational bandwidth, and one or two other frequency carriers (adjacent or
not) in a second operational bandwidth
Other configurations
Other configurations are four-sector, five-sector and six-sector configurations. The Node
B is logically declared at the RNC as four, five, or six cells. Softer handover is controlled
by the network.
According to the number of frequency carriers, the 9944 Smart S18K supports other
configurations with four, five and six sectors with the limitation of 12 cells maximum.
For example, the possible six-sector configurations are the following:
HTHR1
This configuration requires the following characteristics:
Six antenna pairs: 12 antenna ports (one TX/Rx Main and one Div per pair)
One frequency carrier
HTHR2
This configuration requires the following characteristics:
Six antenna pairs: 12 antenna ports (one TX/Rx Main and one Div per pair)
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 3-13
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K basic characteristics 9944 Smart S18K configurations
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
3-14 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
PRELIMINARY
4 4944 Smart S18K hardware
9
description
Overview
Purpose
This chapter describes all the modules (optional or not) implemented in the 9944 Smart
S18K cabinets.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-1
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description 9944 Smart S18K hardware presentation
PRELIMINARY
9944 Smart S18K hardware presentation
....................................................................................................................................................................................................................................
The optional User InterCOnnexion module (User ISO), on the right hand side of the
left compartment, for DC power distribution to user modules.
The Outdoor Control Board (OUTAL-C) , located horizontally on left compartment
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-3
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description 9944 Smart S18K hardware presentation
9944 Smart S18K hardware presentation
....................................................................................................................................................................................................................................
It contains the XIOB, BTSRI, RIBAT and COAR functions and provides connectors
for the external Abis, alarm and clock cables.
The optional PCM Lightning Protection (LPPCM) module, above the d2U rack (in the
WCDMA 900 or 1800 configuration) or above the TRDU sub-rack (in the UMTS
FDD band I (2100/1900 MHz band) configuration)
PRELIMINARY
....................................................................................................................................................................................................................................
4-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description 9944 Smart S18K hardware presentation
PRELIMINARY
9944 Smart S18K hardware presentation
....................................................................................................................................................................................................................................
Equipment layout
The following figure illustrates the blocks layout in the 9944 Smart S18K cabinet
equipped in the WCDMA 900 or 1800 configuration, with 2G legacy modules.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-5
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description 9944 Smart S18K hardware presentation
9944 Smart S18K hardware presentation
....................................................................................................................................................................................................................................
The following figure illustrates the blocks layout in the 9944 Smart S18K cabinet
equipped in the UMTS FDD band I (2100/1900 MHz band) configuration.
Bulkhead
The bulkhead provides cabinet external interfaces. All interfaces are located on removable
bulkheads on bottom/front of cabinet.
PRELIMINARY
PRELIMINARY
9944 Smart S18K hardware presentation
....................................................................................................................................................................................................................................
Right bulkhead is equipped with :
Four holes for M32 cable gland (supporting up to 3 optical CPRI link)
Four double holes for DC RRH outputs (DC filter on 0 and -48V outputs)
One pins circular hole for WCDMA 8 PCM connection
One pins circular hole for external alarms connection
Two M20 and one M16 cable gland holes (not equipped to be ordered separately)
The following figure shows the 9944 Smart S18K left bulkhead.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-7
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description 9944 Smart S18K hardware presentation
9944 Smart S18K hardware presentation
....................................................................................................................................................................................................................................
The following figure shows the 9944 Smart S18K right bulkhead.
....................................................................................................................................................................................................................................
4-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Overview
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Overview
Purpose
This section describes the 3G digital modules housed in the 9944 Smart S18K.
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-9
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Digital modules presentation
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Digital modules presentation
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Digital shelf
The digital shelf houses the following modules:
eXtended Channel Element Module-U (xCEM-U) / enhanced Channel Element
Module-U (eCEM-U)
This module is in charge of:
Part of call processing
Base-band transmit/receive digital signal processing
eXtended Core Controller Module-U (xCCM-U) / enhanced Core Controller
Module-U (eCCM-U)
This module is in charge of:
OAM management
Part of call processing
Internal/external data flow switching or combining
Supporting external/internal alarm connectivity and external synchronization
reference interface
Supporting up to six CPRI interfaces to radio equipment
A fan rack contains two fans and a Rack User Commissioning (RUC) module. The
RUC module is connected to the xCCM-U/eCCM-U via a one-wire link. It supports
all fan alarms.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-11
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Digital modules presentation
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
The following figure illustrates the functional architecture of the d2U.
The digital shelf controls the radio devices (TRDUs and/or RRHs) through electrical
connections carrying digital links compliant with CPRI standard.
The 9944 Smart S18K supports the digital modules listed in the following table.
Module Function
xCCM-U/eCCM-U CCM + GPSAM + OIM
xCEM-U/eCEM-U CEM
RBP Backplane
PRELIMINARY
....................................................................................................................................................................................................................................
4-12 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Digital modules presentation
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
The digital shelf of the 9944 Smart S18K houses four slots, shared as follows:
One for the xCCM-U/eCCM-U (slot 1) (no duplex feature)
Up to three for the xCEM-U/eCEM-Us (slot 2, slot 3, slot 4), depending on the
configuration requirements (one xCEM-U/eCEM-U in the base package)
CCM and CEM module types can be mixed : xCCM-U can support a mix of xCEM-U
and eCEM-U, eCCM-U can support a mix of xCEM-U and eCEM-U.
Unused xCEM-U/eCEM-U slots on a powered 9944 Smart S18K must be equipped with
filler modules. The filler modules maintain electromagnetic interference (EMI) integrity,
as well as shelf airflow patterns to ensure proper cooling.
The following figure shows the digital shelf layout.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-13
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description eXtended Channel Element Module-U (xCEM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Hardware description
The xCEM-U is composed of:
One main board (size 389.6mm x 274.8mm)
One front panel
All the xCEM-U interfaces are located at the rear of the module and connected to the
RBP. The front panel only includes LEDs and debug interfaces.
The following figure shows the xCEM-U front panel.
PRELIMINARY
....................................................................................................................................................................................................................................
4-14 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description eXtended Channel Element Module-U (xCEM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Port description
The xCEM-U front panel also the following connectors:
One Debug Ethernet connector (RJ-45 type connector) for synchronization of test
equipment
One Sync connector (RJ-45 type connector)
These two RJ-45 connectors are not used in normal operation.
LED description
The xCEM-U front panel has two corporate LEDs indicating the xCEM-U status.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-15
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description eXtended Channel Element Module-U (xCEM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Interface description
All signals to and from the xCEM-U are carried on a full duplex High Speed Serial Link
(HSSL).
The main internal signals of the xCEM-U are the base-band data, the ATM traffic
information, the timing signals, and the control signaling.
DC power
The xCEM-U is powered by a -48 V DC power supply received through the RBP.
xCEM-U benefits
The xCEM-U brings the following benefits:
High capacity on a single board (iCEM-U capacity doubled)
Support of R99, HSDPA and HSUPA on a single board
Support of six cells and two frequencies
High flexibility in board configuration
Allocation of HSPA baseband resources of different cells to different xCEM/xCEM-U
boards, even if the cells use the same carrier (up to 3 xCEM/xCEM-U per carrier)
Future capacity increase via multi-mode BBU through optimized software
Future proof architecture with upgrade capability towards High Speed Packet Access
+ (HSPA+) and Long Term Evolution (LTE).
PRELIMINARY
....................................................................................................................................................................................................................................
4-16 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description enhanced Channel Element Module-U (eCEM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Hardware description
The eCEM-U is composed of:
One main board (size 389.6mm x 274.8mm)
One front panel
All the eCEM-U interfaces are located at the rear of the module and connected to the
RBP. The front panel only includes LEDs and debug interfaces.
The following figure shows the eCEM-U front panel.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-17
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description enhanced Channel Element Module-U (eCEM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Port description
The eCEM-U front panel has the following connectors:
One Debug Ethernet connector (RJ-45 type connector) for synchronization of test
equipment (labeled DEBUG ICU)
One Sync connector (RJ-45 type connector) (labeled DEBUG BBU)
These two RJ-45 connectors are not used in normal operation.
LED description
The eCEM-U front panel has four tri-color (green/amber/red) LEDs as illustrated in the
following figure:
....................................................................................................................................................................................................................................
4-18 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description enhanced Channel Element Module-U (eCEM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
The first and second LEDs (from top) are two corporate LEDs indicating the eCEM-U
board status.
First LED (from top) Second LED (from top) eCEM-U status
OFF OFF Sleep, unpowered or not
inserted
Red Green Power up self-test underway
OFF Green Module should not be removed.
Red blinking Green Module is partially faulty.
Red OFF Module must be removed,
alarm state, BISTs NOK.
Red blinking OFF Module is waiting for Boot.
The third LED (from top) indicates the type of software running in the eCEM-U board:
LTE (green)
UMTS (amber)
The fourth LED (from top) is not used.
Interface description
All signals to and from the eCEM-U are carried on a full duplex High Speed Serial Link
(HSSL).
The main internal signals of the eCEM-U are the base-band data, the ATM traffic
information, the timing signals, and the control signaling.
DC power
The eCEM-U is powered by a 48 V DC power supply received through the RBP.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-19
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description enhanced Core Controller Module-U (eCCM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Hardware description
The eCCM-U is based on a motherboard and a Media Dependent Adaptor (MDA).
The following two hardware configurations are available:
eCCM-U motherboard with a E1/T1 MDA (eCCM-U-4E1)
eCCM-U motherboard with a Gigabit Ethernet (GE) MDA (eCCM-U-GE)
PRELIMINARY
....................................................................................................................................................................................................................................
4-20 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description enhanced Core Controller Module-U (eCCM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Port description
The eCCM-U front panel has the following connectors:
PRELIMINARY
One GPS synchronization port (RJ-45 female connector) used for connecting a PPS
source from an external GPS receiver (labeled GPS)
Six SFP cages used for connections to radio modules (labeled OPTIC 1,
OPTIC 2, OPTIC 3, OPTIC 4, OPTIC 5, OPTIC 6)
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-21
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description enhanced Core Controller Module-U (eCCM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
These ports support the following protocols:
Ports one, two and three support CPRI at rates 2 (1.2288 Gb/s) and 3
(2.4576 Gb/s)
Ports four, five and six support CPRI at rates 2 (1.2288 Gb/s) and 3 (2.4576 Gb/s)
or HSSL.
One Dallas one-wire interface connector (RJ-45 female connector) for
internal/external alarm module connectivity and commissioning (labeled ALARM)
One dual SMB female connector providing:
One 10/15 MHz input synchronization clock (labeled "IN")
One 10/15 MHz output clock used for inter-rack synchronization (labeled "REF
OUT")
One port (RJ-45 female connector) used for TIL connection or SiteLAN (labeled
PORT 1)
One Fast Ethernet 10/100/1000Base-T port (RJ-45 female connector labeled
"PORT 2") used for management of collocated OEM devices, such as tilt antenna, or
for Hybrid-Iub connectivity
Note: if the eCCM-U is equipped with MDA E1/T1, only rates up to 100 FE are
supported on the port.
Note: this port can only be used for Iub if the card is equipped with MDA E1/T1. If
the card is equipped with MDA GE port 2 cannot be used for Iub.
Note: an Ethernet isolator must not be connected in the line, unlike the xCCM-U.
One 4-E1/T1 connector (26-pin High Density D-SUB female connector) used for
E1/T1 connection (labeled PCM E1/T1)
One 4-E1/T1 connector (25-pin D-SUB female connector) used for E1/T1 connection
(labeled "MDA") when the MDA E1/T1 is plugged in.
Two SFP cages (1000BaseX) and one RJ-45 (100/1000Base-T) connector for two
Ethernet physical ports when the MDA GE is plugged (used for Hybrid IP or Native
IP Iub connectivity).
Note: The second SFP and the RJ-45 connector share the same Ethernet port.
Note: Only one of the three GE connectors can be used for Iub in this release.
The eCCM-U front panel also has one Reset button.
LED description
The eCCM-U front panel has four groups of four tri-color LEDs (green, red or amber) as
illustrated in the following figure.
PRELIMINARY
....................................................................................................................................................................................................................................
4-22 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description enhanced Core Controller Module-U (eCCM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Four tri-color MDA LEDs which indication depends on the eCCM-U hardware
configuration:
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-23
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description enhanced Core Controller Module-U (eCCM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
For the eCCM-U-4E1 hardware configuration:
Link OK (green)
Link showing an alarm (red)
Link in tri-state (amber)
Link not used (OFF)
Link in loopback test (blinking)
For the eCCM-U-GE hardware configuration, the tri-color LEDs one, two and three
are dedicated to the three GE ports (the LED four is not used):
The port is not configured (OFF)
The port is configured and is well-connected (green)
The port is configured and there is a problem on the connection (amber)
The port is configured but not selected by the software in case of
multi-configuration (red)
Four tri-color PCM LEDs indicating:
Link OK (green)
Link showing an alarm (red)
Link in tri-state (amber)
Link not used (off)
Link in Loopback Test (blinking)
In addition to the CMA/SYNC/MDA/PCM tri-color LEDs, the eCCM-U has two LEDs
on each Ethernet port:
Ethernet Link status (green LED)
Ethernet Rx/Tx activity (yellow LED)
Interface description
The eCCM-U is linked with each xCEM-U/eCEM-U by a point-to-point HSSL
connection.
Three CPRI interfaces link the eCCM-U to TRDU or RRH radio equipment
Three CPRI/HSSL interfaces link the eCCM-U to TRDU, RRH or MCTRX radio
equipment.
The eCCM-U provides Iub over PCM through the following combination:
4 E1/T1 connections on the eCCM-U module
PRELIMINARY
....................................................................................................................................................................................................................................
4-24 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description enhanced Core Controller Module-U (eCCM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
The eCCM-U provides an Iub IP connection through one of the following options:
Optical GE via one SFP GE port of the MDA GE
Electrical GE via the RJ45 connector on the MDA GE
FE via Port 2 of the eCCM-U if MDA GE is not used.
DC power
The eCCM-U is powered by a 48 VDC power supply received through the RBP.
The eCCM-U is protected against polarity inversion.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-25
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description eXtended Core Controller Module-U (xCCM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Hardware description
The xCCM-U is based on a mother board and a Media Dependent Adaptor (MDA),
PRELIMINARY
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
The following figures show the xCCM-U front panel.
Port description
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-27
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description eXtended Core Controller Module-U (xCCM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
One Dallas one-wire interface connector (RJ-45 female connector) for internal Node
B/external Node B alarm and commissioning (labeled "ALARM")
One timing reference port (10 MHz output reference clock - SMB female connector)
(labeled "REF OUT")
One fast Ethernet 10/100Base-T port (RJ-45 female connector) used for TIL
connection or SiteLAN (labeled "PORT 1")
Note: To connect a local terminal, if SiteLAN is used, it must be disconnected. An
alternative solution is to use an Ethernet hub.
Note: To use this port for FE IUB connection, an Ethernet isolator must be connected
in the line.
One Fast Ethernet 10/100Base-T port (RJ-45 female connector labeled "PORT 2")
used for management of co-located OEM devices, such as tilt antenna, or for
Hybrid-Iub connectivity
Note: this port can only be used if the card is equipped with MDA E1/T1. If the card
is equipped with MDA-GE port 2 cannot be used.
One 4-E1/T1 connector (26-pin High Density D-SUB female connector) used for
E1/T1 connection (labeled "PCM E1/T1")
One 4-E1/T1 connector (25-pin D-SUB female connector) used for E1/T1 connection
(labeled "MDA") when the MDA E1/T1 is plugged in.
Two SFP cages (1000BaseX) and one RJ45 (10/100/1000Base-T) connector for two
Ethernet physical ports when the MDA GE is plugged in.
Note: The second SFP and the RJ45 connector share the same Ethernet port.
Note: Only one of the three GE connectors can be used for Iub in this release.
The xCCM-U front panel also has a Reset button.
LED description
The xCCM-U front panel has the following LEDs:
Two corporate LEDs indicating the xCCM-U status:
Table 4-4 xCCM-U corporate LEDs status
be removed
BLINK Not significant Downloading in progress
....................................................................................................................................................................................................................................
4-28 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description eXtended Core Controller Module-U (xCCM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Table 4-4 xCCM-U corporate LEDs status (continued)
are dedicated to the three GE ports (the LED four is not used):
The port is not configured (off)
The port is configured and is well-connected (green)
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-29
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description eXtended Core Controller Module-U (xCCM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
The port is configured and there is a problem on the connection (amber)
The port is configured but not selected by the software in case of
multi-configuration (red)
One bi-color LED (green or red) indicating the Activity status of the board
On each Ethernet port:
One green LED indicating the Ethernet Link status
One amber LED indicating the Ethernet Rx/Tx activity
Interface description
The xCCM-U is linked with each xCEM-U/eCEM-U by a point-to-point HSSL
connection.
Three CPRI interfaces link the xCCM-U to TRDU or RRH radio equipment
Three CPRI/HSSL interfaces link the xCCM-U to TRDU, RRH or MCTRX radio
equipment.
The xCCM-U provides Iub over PCM through the following combination:
4 E1/T1 connections on the xCCM-U module.
4 E1/T1 connections on the MDA E1/T1
The xCCM-U provides Hybrid-Iub IP connection through one of the following options:
Optical GE via one SFP GE port of the MDA GE
Electrical GE via the RJ45 connector on the MDA GE
FE via Port 2 of the xCCM-U, using an Ethernet isolator in the line
DC power
The xCCM-U is powered by a 48 VDC power supply received through the RBP.
The xCCM-U is protected against polarity inversion.
TRDU/RRH mixity
Note: Within a cluster, TRDU/RRH module type must be homogeneous (eg:
3 x TRDU60-21, or 3 x TRDU60-21B, but not 2 x TRDU60-21 + TRDU60-21B).
Between two clusters, different TRDU/RRH module types can be used (some
examples are: 3 x TRDU60-21 + 3 x TRDU40W, or 3 x TRDU60W + 3 x RRH, or 3
x TRDU60-21 + 3 x TRDU60-21B, ...).
PRELIMINARY
....................................................................................................................................................................................................................................
4-30 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description eXtended Core Controller Module-U (xCCM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
The xCCM-U front panel provides connectivity for six CPRI cables:
Up to six TRDUs can be connected (electrical connections).
For higher sectorization (three local sectors and three remote sectors), it is also
possible to connect up to three TRDUs and three RRHs (in a two-carrier configuration
maximum).
In this mixity case, the connections (electrical for TRDUs, optical for RRHs) must be
done according to the following figure.
The SFP cages supporting the connection with the RRHs must be equipped with optical
transceivers. These optical transceivers must be provisioned according to the optical
interface available on the RRH (Multi-Mode (MM) or Single-Mode (SM), dual or single
fiber).
The distance between the Node B and the RRH determines the optical mode (MM or
SM):
MM dual fiber is used for short distance (up to 500 m): one fiber carries the downlink
signal and a second one the uplink signal.
SM single fiber is used for long distance (up to 20 km): one single fiber carries both
downlink and uplink signals using separate wavelength.
PRELIMINARY
SM dual fiber is used for long distance (up to 20 km): one fiber carries the downlink
signal and a second one the uplink signal.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-31
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description eXtended Core Controller Module-U (xCCM-U)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Connectivity with RRH20-21 variant of RRH device
The connection of RRH20-21 devices (only supporting HSSL interface) to the xCCM-U
module requires the following three ports to be used on the xCCM-U front panel:
Optical port 4, for connection to the RRH20-21 number 1
Optical port 5, for connection to the RRH20-21 number 2
Optical port 6, for connection to the RRH20-21 number 3
Nevertheless, on the TIL or at WMS level, the three RRHs appear as if they were
connected on optical ports 1, 2 and 3.
At WMS level, the RRHs must be declared as follows: antennaConnection _11 for the
first, antennaConnection _21 for the second, and antennaConnection _31 for the third
RRH. These informations are sent to the Node B in the DownLoading Unit (DLU). A
DLU parameter informs the Node B that the RRH connected is a RRH20-21 and operates
in HSSL format.
When the RRH tries to connect on the optical port of the xCCM-U (port 4, 5 or 6), the
Node B:
Recognizes that the RRH is HSSL-compliant
Proceeds an address translation of RRH HSSL port (41 to 11, 51 to 21, 61 to 31)
Declares to the WMS the connection of the RRH instance 11, 21 or 31
900 MHz band. This function can provide a mixed 2G/3G configuration in the 900 MHz
band, or a 3G configuration in both 900 MHz and 2100 MHz bands using MC-TRX and
TRDU or RRH.
....................................................................................................................................................................................................................................
4-32 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description eXtended Core Controller Module-U (xCCM-U)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
The connection of MC-TRX modules to the xCCM-U module requires the following
three ports to be used on the xCCM-U front panel:
Optical port 4, for connection to the MC-TRX number 1
Optical port 5, for connection to the MC-TRX number 2
Optical port 6, for connection to the MC-TRX number 3
Optical ports one to three can be connected to 2100 MHz radio devices (TRDU or RRH).
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-33
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description d2U fan tray (48V)
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-34 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description d2U fan tray (48V)
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Operating principle
The cooling air paths through the digital shelf operate as follows:
The air enters on the right side of the digital shelf.
The air is drawn through the digital shelf to cool the digital modules.
The air is exhausted from the left side of the digital shelf.
The following figure illustrates the air flow paths through the d2U shelf.
Fans DC power
The two fans are power-supplied through the power connector located on the RUC front
panel.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-35
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Rack User Commissioning module (RUC for d2U (V2/V3))
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
Hardware description
The following figure shows the RUC module front panel.
PRELIMINARY
....................................................................................................................................................................................................................................
4-36 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Rack User Commissioning module (RUC for d2U (V2/V3))
PRELIMINARY
9944 Smart S18K digital modules
....................................................................................................................................................................................................................................
DC power
The RUC module is powered with external 48 V DC.
The power consumption (including the fans power consumption) is estimated at 10 W.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-37
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Physical characteristics of the 9944 Smart S18K digital
9944 Smart S18K digital modules modules
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-38 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Overview
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
Overview
Purpose
This section describes the 3G radio modules housed in the 9944 Smart S18K.
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-39
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Radio modules presentation
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-40 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Radio modules presentation
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
The following figure shows an outside view of the TRDU sub-rack with one TRDU ICO
module inserted.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-41
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Radio modules presentation
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
The following figure shows a front view of the TRDU sub-rack fully equipped with six
TRDUs, two TRDU ICO modules and one TRCU.
....................................................................................................................................................................................................................................
4-42 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Transmitter Receiver Duplexer Unit (TRDU)
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
Main functions
The TRDU module integrates the following three functions in a single module:
Transceiver
Multi-carrier power amplifier
Duplexer/filter
The TRDU6021 or TRDU60-21B module can manage up to four adjacent carriers in
UMTS Band I (2110-2170 MHz in downlink; 1920-1980 MHz in uplink) with the
following characteristics:
Downlink: one transmit chain supporting up to four adjacent UMTS carriers (carrier
spacing between 4.6 MHz and 5.2 MHz)
Uplink: dual receive chain in a main/diversity arrangement supporting four adjacent
carriers
RF air interface is supported through two antenna connections:
One duplexed antenna connection supporting transmit and receive main paths
(Antenna Main)
One single antenna connection supporting receive diversity path (Antenna Div).
Base band interface is supported through:
TRDU60-21 or TRDU60-21B: two CPRI links, support of CPRI rate 2 (1.2288 Gbps)
PRELIMINARY
and CPRI rate 3 (2.45 Gbps) for daisy chaining or, in a future use, dual slave (UMTS
+ LTE) connection
The TRDU module includes a DC/DC converter for the -48 V DC power supply
conversion.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-43
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Transmitter Receiver Duplexer Unit (TRDU)
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
The TRDU module incorporates a Voltage Standing Wave Ratio (VSWR) meter to
monitor RF mismatching between antenna and TRDU main antenna connection. This
VSWR meter monitors Return loss at antenna main port connection. Two VSWR
thresholds are monitored, corresponding to two alarm levels reported on CPRI interface.
The TRDU module also provides an Antenna Interface Standard Group (AISG)
functionality.
The following figure illustrates the internal architecture of the TRDU module.
The TRDU module can be used in different modes regarding antenna system, depending
on Tower Mounted Amplifier (TMA) use and/or AISG Antenna Line Device (ALD) use:
No TMA mode
Antenna outputs and antenna(s) are directly connected through RF feeders.
TMA mode
An additional amplifier is added on each antenna branch in order to compensate
feeder loss on uplink path.
Two sub-modes with TMA can be used:
TMA UMTS mode: in this mode, the TMA is powered and monitored from the
TRDU module.
PRELIMINARY
TMA Mix mode: in this mode, the TRDU module manages only extra gain on
uplink paths introduced by the TMA. This mode can be used in case of antenna
sharing with another system (the TMA is powered and monitored from this
system), or in case of AISG TMA (the TMA is powered and monitored by the
AISG primary device).
....................................................................................................................................................................................................................................
4-44 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Transmitter Receiver Duplexer Unit (TRDU)
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
Hardware description
The TRDU60 module is designed as a standalone unit, mounted in a closed metal housing
fitted with a heat sink. It provides two RF coaxial antenna connections, a CPRI input for
connection to the xCCM-U/eCCM-U module, and a CPRI output for daisy chaining or, in
a future use, dual slave (UMTS and LTE).
The following figure shows the TRDU6021 front panel.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-45
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Transmitter Receiver Duplexer Unit (TRDU)
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
The following figure shows the TRDU6021B front panel.
Connectors
The TRDU6021 and TRDU60-21B front panel provide the following connectors:
One RF Antenna Main port (7/16 female connector) used for duplexed transmit and
PRELIMINARY
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
One DC power input (3-pin Mini Fit Jr. connector) used for TRDU -48 V DC power
supply (labeled "POWER IN")
One CPRI input used for connection to xCCM-U/eCCM-U (labeled "DATA I/O
SLAVE")
One CPRI output used for daisy chaining or, in a future use, dual slave (UMTS +
LTE) (labeled "DATA I/O MASTER")
One Ethernet connector (RJ-45 type connector) used for debug activities (labeled
"ETHERNET")
One AISG input (9-pin D-SUB male connector with female screw locks) used for
connection to AISG RS485/DC line bus from AISG primary device (labeled "AISG
IN")
LEDs behavior
The TRDU6021 and TRDU60-21B front panel have two circle-shaped LEDs indicating
the TRDU status.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-47
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Transmitter Receiver Duplexer Unit (TRDU)
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
In addition, the TRDU60-21B variant front panel has two circle-shaped LEDs indicating
the two CPRI links status.
....................................................................................................................................................................................................................................
4-48 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description TRDU InterCOnnection (TRDU ICO) module
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
Main functions
The TRDU ICO module is used to power-supply the following equipment:
Up to three TRDU modules
The TRDU sub-rack Cooling Unit (TRCU)
A user optional equipment (such as the CCU for RETA)
The TRDU ICO module distributes -48 V DC power. It contains a thermal switch that
prevents the power supply of the TRDUs if the temperature is below -5C.
Hardware description
The TRDU ICO module is powered from the PSU.
All the interfaces are accessible from the front panel of the TRDU ICO module.
The following figure shows the front panel of the TRDU ICO module.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-49
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description TRDU InterCOnnection (TRDU ICO) module
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
The front panel of the TRDU ICO module provides:
One Mini-Fit Sr. input power connector ("PWR IN") used for connection to the PSU
Three 1-row/3-way Mini Fit Jr. output power connectors ("J3 TRDU1/4", "J4
TRDU2/5", "J5 TRDU3/6") used for power distribution to the TRDUs
One 1-row/3-way Mini Fit Jr. output power connector ("J1 TRCU") used for power
distribution to the TRCU
Note: For a configuration including more than three TRDUs, the TRCU is
power-supplied through the TRDU ICO 1 only. The "J1 TRCU" connector of the
TRDU ICO 2 is not used.
One 1-row/3-way Mini Fit Jr. output power connector ("J2 AUX") used for power
distribution to the CCU for RETA (or another optional equipment)
The five output power connectors are protected with individual fuses.
PRELIMINARY
....................................................................................................................................................................................................................................
4-50 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description TRDU sub-rack Cooling Unit (TRCU)
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
Main functions
The installed TRDU equipment is cooled by a ventilation unit named TRDU sub-rack
Cooling Unit (TRCU). It is installed at the bottom of the TRDU sub-rack and provides a
vertical air flow.
Operating principle
The cooling air paths operate as follows:
The air enters at the bottom part of the TRDU sub-rack.
The air is pushed through the installed TRDU equipment.
The air is exhausted through the top of the TRDU sub-rack.
Hardware description
The TRCU is composed of the following parts:
Three axial DC fans
One temperature control sensor
One Printed-Circuit Board Assembly (PCBA) for control functions, power supply and
alarm LED
The following figure shows the TRCU front panel.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-51
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description TRDU sub-rack Cooling Unit (TRCU)
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
The TRCU front panel has the following connectors:
One 1-row/3-way Mini Fit Jr. input power connector ("J2 PWR IN"), used for power
supply from the TRDU ICO module (it provides DC power for the TRCU PCBA and
the fans)
One input internal alarm RJ-45 female connector ("J3A ALARM IN") used for
connection to the RUC module of the BBU
It provides:
One-wire link (for inventory and alarm detection)
Associated power distribution (5 V)
The TRCU inventory and alarms are polled by the xCCM-U/eCCM-U board. The
alarms triggered by the TRCU (xCCM-U/eCCM-U board: one-wire) are:
Fans
Temperature sensor failure
One output internal alarm RJ-45 female connector ("J3B ALARM OUT") used for
connection of the optional modules of the cabinet through the Dallas one-wire bus.
One RJ-45 connector ("J6 IHM") for debug purposes
The TRCU front panel also has one LED indicating the TRCU alarm status: the LED is
green for normal operation and turns red for a malfunction.
PRELIMINARY
....................................................................................................................................................................................................................................
4-52 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Physical characteristics of the 9944 Smart S18K radio
PRELIMINARY
9944 Smart S18K radio modules modules
....................................................................................................................................................................................................................................
Module name Qty Width (mm) Height Depth (mm) Weight (kg)
(mm)
TRDU6021 Up to 6 73.7 325.6 350 8.5 (per unit)
TRDU6021B Up to 6 73.7 325.6 350 9.5 (per unit)
TRDU ICO Up to 2 222 63.5 50 1 (per unit)
TRCU 1 444 60 350 4
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-53
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Multi-Carrier TRX900 (MC-TRX)
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
Main functions
The MC-TRX 900 module integrates the following functions into one single module:
Transceiver
One multi-carrier power amplifier ( MCPA)
The MC-TRX control interface is based on
PRELIMINARY
CPRI protocol (L1/L2) over optical/electrical link between BBU and MC-TRX for 3G
application
Original 2G interface (through backplane) between SUMX 2G application
....................................................................................................................................................................................................................................
4-54 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Multi-Carrier TRX900 (MC-TRX)
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
The MC-TRX CPRI link activation/deactivation is managed by 2G system.
The following figure illustrates the internal architecture of the MC-TRX module:
Two CPRI links, supporting CPRI rate 2 (1.2288 Gbps) and CPRI rate 3 (2.45 Gbps)
for daisy chaining (not yet available for S8K or S18K systems) or, in a future use,
dual slave (UMTS + LTE) connection
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-55
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Multi-Carrier TRX900 (MC-TRX)
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
Hardware description
The MC-TRX module is designed as a standalone unit. It provides three RF coaxial
connections, a CPRI input for connection to the xCCM-U/eCCM-U module and a CPRI
output for daisy chaining (not yet available for S8K or S18K systems) or, in a future use,
dual slave (UMTS and LTE).
The following figure shows MC-TRX front panel
....................................................................................................................................................................................................................................
4-56 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Multi-Carrier TRX900 (MC-TRX)
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
MC-TRX connectors
The MC-TRX front panel provides the following connectors:
One Receiver RF input (SMB connector) labeled RX0 connected to the Antenna
Network Rx0
One Receiver RF input (SMB connector) labeled "RX1" connected to the Antenna
Network Rx1
One Transmitter RF output (SNAP N connector) labeled TX connected to the
Antenna Network TxIn
By convention, the MC-TRX 2G is connected to the Antenna Network (AGX)
TXA/RXA, the MC-TRX 3G is connected to the Antenna Network TXB/RXB.
On the Antenna Network, AntA is connected to the Antenna main, AntB connected to
the Antenna Div.
One CPRI input (single Small Form factor Pluggable (SFP) 20-pin receptacle) used
PRELIMINARY
....................................................................................................................................................................................................................................
4-58 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Multi-Carrier TRX900 (MC-TRX)
PRELIMINARY
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
Table 4-9 MC-TRX LEDs management description (continued)
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-59
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description MC-TRX physical characteristics
9944 Smart S18K radio modules
....................................................................................................................................................................................................................................
MC-TRX Consumption
The MC-TRX supports up to 3 UMTS carriers and total transmit power is 60 W (3x20
W).
....................................................................................................................................................................................................................................
4-60 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Overview
PRELIMINARY
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Overview
Purpose
This section describes the power system of the 9944 Smart S18K.
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-61
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description 9944 Smart S18K power supply
9944 Smart S18K power system
....................................................................................................................................................................................................................................
PRELIMINARY
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Main functions
The rectifiers provide a nominal -48 V DC.
Each rectifier provides 1000 or 1400 W, according to its type.
The rectifier rack supplies the following cabinet modules via the DC distribution panel :
SR1 or RRH
SR2 or RRH
SR3
TRDU ICO1 or RRH
TRDU ICO2 or RRH
d2UV3
d2UV5
User space via the user ICO
Batteries
ECU
Hardware description
The 9944 Smart S18K contains four rectifiers, over five rectifier slots, in STSR
configuration.
The missing rectifiers must be replaced by fillers.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-63
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description 9944 Smart S18K rectifiers
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Figure 4-34 9944 Smart S18K 1000 W or 1400W rectifier front panel
PRELIMINARY
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Main functions
The CCU performs the following main functions:
It controls the rectifier module through an I2C bus in order to monitor the alarm
module, collect the inventory information, and control output voltage.
It manages the battery back-up system and supports basic features like temperature
compensation and charge current control, and advanced features like battery fault
detection.
It controls the rectifier output current shared in order to enhance system performance
and rectifier reliability.
It measures the system back-up battery temperature for one probe
It monitors the system back-up battery current through a system resistive shunt.
It communicates with the Node B system controller through a DALLAS one wire
interface.
It monitors the system ambient temperature through a dedicated input (CEATS from
the cooling system). The local temperature measurement (CAT) is only used for
thermal alarm management.
It controls the shutdown of the Node B system equipment in order to protect from
extreme voltage or temperature conditions
Hardware description
The front panel of the CCU board includes the following connectors:
J1 connector (26 pin HD D-sub Female): UART
J3 connector (9 pin D-sub Female): 1-WIRE & CEATS.
J4 connector (Universal MATE-N-LOK Pin Header Assembly): Battery thermal
probe
The CCU board adds the J2 connector (48-pin Metal, pin 8B last-make-first-back)
located on shelf backplane
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-65
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Cabinet Control Unit (CCU)
9944 Smart S18K power system
....................................................................................................................................................................................................................................
LED Color
A1, A2, and C2 Red
C1 Green
PRELIMINARY
....................................................................................................................................................................................................................................
4-66 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Cabinet Control Unit (CCU)
PRELIMINARY
9944 Smart S18K power system
....................................................................................................................................................................................................................................
The following table gives the CCU C1 and C2 corporate LED status.
C1 C2 CCU status/condition
Green Switched OFF None of the following
alarms asserted:
CCU_FAULT
ISEn
BTHMn, BAT_T_Hn,
BAT_T_Ln,
BAT_T_DIF
LV, HV
HT, LT
BOD
BAT_BRK or
LOAD_BRK
RFAn
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-67
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Cabinet Control Unit (CCU)
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Table 4-13 CCU C1 and C2 corporate LED status (continued)
C1 C2 CCU status/condition
Switched OFF Red CCU_FAULT alarm
asserted, CCU running in
application code
POST fault, CCU running
in bootloader code
LCOD command process
fault, CCU running in
bootloader code
Switched OFF Switched OFF Critical CCU fault or no input
power
The following table gives the CCU A1, A2 and A3 LED status.
....................................................................................................................................................................................................................................
4-68 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description DC Distribution Unit (DDU) and DC Breaker Panel
PRELIMINARY
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Main functions
The main functions of the DDU module are the following:
Distribution of the DC power to the following entities:
.
One 15A breaker output labelled ECU: to ECU (control board and fans)
One 30A breaker output labelled DIGITAL/RICO: to User ICO and d2UV5
(future release)
Two 60A outputs (RF0, RF1) supplying an additional DC Breaker Panel
Protection of DC load outputs against over currents
DC connection/disconnection under CCU control
Secure disconnection at 40 V
Inventory alarm interface
Connection of internal or external battery
Physical mounting dedicated to the UCPS rack
Hardware description
The front panel of the DDU board includes the following connectors:
J4 connector: RF0, RF1, DIGITAL/RICO, and ECU
J5 connector: Loads RTN
J6 and J7 connectors: DC Battery In/Out power
J8 connector: User ICO
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-69
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description DC Distribution Unit (DDU) and DC Breaker Panel
9944 Smart S18K power system
....................................................................................................................................................................................................................................
The DDU board adds the following connectors located on the shelf backplane:
J1 connector: DDU control
J2 and J3 connectors: DC In Power
The following table summarizes the DDU connectors.
....................................................................................................................................................................................................................................
4-70 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description DC Distribution Unit (DDU) and DC Breaker Panel
PRELIMINARY
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Table 4-15 DDU connectors (continued)
Connected to the UCPS DDU, an additional DC Breaker Panel is used to split the two
60A DC outputs:
RF1 output (60A) is splitted into three additional 30A outputs: SR1, SR2, SR3 to
supply GSM STASR Subracks
RF2 output (60A) is splitted into three additional outputs: two 30A outputs to be used
either for TRDU ICO supply or RRH supply and a 15A output to be used for dUV3
supply
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-71
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description AC Distribution Unit (ADU)
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Main functions
The AC distribution unit distributes the AC power to the following items:
UCPS shelf (also called UCPS rack)
ECU Heaters (Heaters 1&2)
Plug kit
Note: The Plug kit is different for each country AC format. The adaptation to the
different power networks is managed outside the ADU, on the AC terminal block.
The following table gives the AC power formats.
AC power Description
240 V Split phase 120/240 V AC, 50 or 60 Hz
120 V Two phase 120/208 V AC, 60 Hz, Y-connected
230 V Single Phase Single Phase, 220-240 V AC, 50/60 Hz
230 V Three Phase 230/400 V AC, 50 Hz, 3-phase, Y-connected
The ADU is also connected to AC terminal block (also called AC block) for adaptation to
three different types of AC power networks (split, single, and three phases).
The ADU is composed of the following entities:
Lightening protector
Rectifier circuit breakers
ECU circuit breaker
Electromagnetic Interference (EMI) filtering
The following scheme presents the ADU entity connections.
PRELIMINARY
....................................................................................................................................................................................................................................
4-72 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description AC Distribution Unit (ADU)
PRELIMINARY
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Hardware description
The ADU front panel includes the following components:
One UMTS alarm connector
One GSM alarm connector
Three circuit breakers:
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-73
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description AC Distribution Unit (ADU)
9944 Smart S18K power system
....................................................................................................................................................................................................................................
One connector dedicated to UCPS rectifier connections
One connector dedicated to ECU heater connections
....................................................................................................................................................................................................................................
4-74 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Univity Compact Power System (UCPS)
PRELIMINARY
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Main functions
The UCPS manages the following entities:
Rectifiers
Batteries
Interfaces with the GPSAM (for standard 9311 Macro Node B Outdoor systems), with
x/eCCM-U (for 9311 Macro OD V2 with DBS 4U), or the Dallas Master Board
(S18K systems)
The UCPS shelf is a passive backplane which provides the required interconnection for
the rectifiers, the CCU, and the DDU.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-75
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Univity Compact Power System (UCPS)
9944 Smart S18K power system
....................................................................................................................................................................................................................................
Hardware description
The UCPS is made of the following parts:
A CCU board
Up to five rectifiers
A DDU board
A back panel to interconnect all modules
There is one UCPS per Node B cabinet.
The following figure shows the UCPS shelf and modules.
....................................................................................................................................................................................................................................
4-76 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Overview
PRELIMINARY
9944 Smart S18K cooling and heating system
....................................................................................................................................................................................................................................
Overview
Purpose
This section describes the cooling and heating system of the 9944 Smart S18K.
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-77
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description 9944 Smart S18K cooling and heating system presentation
9944 Smart S18K cooling and heating system
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-78 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description 9944 Smart S18K Environmental Control Unit (ECU)
PRELIMINARY
9944 Smart S18K cooling and heating system
....................................................................................................................................................................................................................................
Hardware description
The main components of the ECU are the following:
Two DC blowers
One printed circuit assembly for control functions
One air filter
One damper
One modulating DC motor
One air inlet switch
Two temperature control sensors
Two heaters and their associated thermostats
Operating principle
The cooling air paths within the cabinet operate as follows:
Air enters at the bottom front section of the right and left doors
The air is drawn upward within the door and through a filter to the cooling system
It is pushed through a duct at the rear of the cabinet (Cooling duct)
It is distributed to the two equipment columns of the cabinet
Right column: pushed through the sub-rack equipment
Left column: pushed through the sub-rack equipment
It is evacuated though the lower front section of the door, or re-circulated through the
cooling system depending on the cooling requirements.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-79
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description 9944 Smart S18K Environmental Control Unit (ECU)
9944 Smart S18K cooling and heating system
....................................................................................................................................................................................................................................
Operating modes
The cooling unit system is able to operate in the following mode:
Non-speed control mode
This mode is chosen and no fault condition is detected, fans operate continuously at
PRELIMINARY
PRELIMINARY
9944 Smart S18K cooling and heating system
....................................................................................................................................................................................................................................
The cooling system senses the external ambient temperature and automatically select
slow (S1 or S5), medium (S2 or S6), or high (S3 or S7) fan speed.
Slow speed operation of the fans (S1 or S5) is selected if the ambient external air
temperature is below +40C and no fault condition is detected by the cooling system
control PCB.
Medium speed operation of the fans (S2 or S6) is selected if the ambient external air
temperature is above +40C and no fault condition is detected by the cooling system
control PCB. Under this condition the filter clog alarm is inhibited, it is automatically
reset once the slow fan speed (S1 or S5) has been re-selected by the PCB.
High speed operation of the fans (S3 or S7) is selected if the ambient external air
temperature is above +55C and no fault condition is detected by the cooling system
control PCB. Under this condition the filter clog alarm is inhibited, it is automatically
reset once the slow fan speed (S1 or S5) has been re-selected by the PCB.
Full speed operation of the fans (S4) is selected if one of the following condition
occurs:
Single fan failure
Ambient external sensor failure
LED description
The control board of the ECU monitors the performance of the cooling and heating
circuits.
The cooling system control board is fitted with nine LED failure indicators for on site
maintenance. All LED indicators are green illuminated in normal operation and red
illuminated on indication of the failure.
The LED sequence is as follows:
Green illuminated = Fan 1 OK
Green illuminated = Fan 2 OK
Green illuminated = Heater 1 OK
Green illuminated = Heater 2 OK
Green illuminated = Damper OK
Green illuminated = Filter OK
Green illuminated = Ambient thermistor OK
Green illuminated = Internal thermistor OK
Green illuminated = Internal temperature outside range OK
The LED indicators are visible from the front panel of the cooling system.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-81
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description 9944 Smart S18K Environmental Control Unit (ECU)
9944 Smart S18K cooling and heating system
....................................................................................................................................................................................................................................
Electrical specification
The ECU uses a dual power supply :
AC 230V for heaters powering
DC -48V for ECU control board and FAN system powering
During normal operation the ECU uses only DC supply.
PRELIMINARY
....................................................................................................................................................................................................................................
4-82 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Overview
PRELIMINARY
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
Overview
Purpose
This section describes the other equipment of the 9944 Smart S18K.
It is not an exhaustive list of all other items: in particular, this section does not provide
information on cables kits and installation sets (ancillaries).
All the equipment described in this section are optional equipment, except the mandatory
OUTAL-C board and Dallas master board.
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-83
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description User ICO module
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
Main functions
The User ICO module is required as soon as user specific modules are installed in the
User Rack.
The User ICO module performs:
Protection and DC distribution to user modules
Collection of alarms from user modules
Hardware description
The User ICO front panel has:
Four power connectors (Mate-n-lock with locking lances and locating pin, female
housing) for -48 V DC
Four standard fuses: Little fuse 2.5 A: T 2.5 A 48 V (slow blow), 5x32 type
Each power connection (-48 V DC) is protected by one fuse of 2.5 A. It is possible to
change the value of each fuse, but the sum of the four values must not exceed 10 A
maximum.
Alarm connectors:
GSM Alarm : 9-pin D-sub female connector, connected to the OUTAL-C.
"User Alarm": 9-pin D-sub female connector, on which customer equipment
alarms are connected
For UMTS and GSM applications, a maximum of four alarms can be processed for
fault management.
The following figure shows the User ICO module front panel.
PRELIMINARY
....................................................................................................................................................................................................................................
4-84 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description User ICO module
PRELIMINARY
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
Pin Signal
1 User 0
2 User 1
3 User 2
4 GND
5 GND
6 GND
PRELIMINARY
7 User 3
8 User 4
9 User 5
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-85
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description User ICO module
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
Alarms 0 to 5 of the User Alarm connector are connected by the User ICO to the
OUTAL-C, for both GSM and WCDMA..
PRELIMINARY
....................................................................................................................................................................................................................................
4-86 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description OUTdoor ALarm board Converged (OUTAL-C)
PRELIMINARY
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-87
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description OUTdoor ALarm board Converged (OUTAL-C)
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
Hardware description
The following figure shows the front panel of the OUTAL-C board.
....................................................................................................................................................................................................................................
4-88 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Dallas master board
PRELIMINARY
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-89
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description PCM Lightning Protection (LPPCM) module
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
Main functions
The LPPCM module provides lightning protection for up to eight PCM links.
Hardware description
The following figure shows the front panel of the LPPCM module.
The front panel of the LPPCM module has the following connectors:
Two 37-pin D-SUB female connectors (labeled "PCM Out") to connect the module to
the xCCM-U/eCCM-U
Note: The right-hand connector labeled "PCM Out" is not used.
One 37-pin D-SUB female connector (labeled "PCM In") for PCM connection to the
customer DDF (through the W-CDMA bulkhead)
Two Internal Alarm Bus 9-pin D-SUB female and male connectors (labeled "OUT"
PRELIMINARY
....................................................................................................................................................................................................................................
4-90 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description AISG Tower Mounted Amplifier (AISG TMA)
PRELIMINARY
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
Main functions
The AISG TMA allows to decrease the overall noise level by amplifying the received RF
signal.
In UMTS 2100, the AISG TMA 2100 input/output (from the Node B) is used for
transmission and reception for main path or diversity path. One AISG TMA 2100 is used
per sector.
The AISG TMA provides an AISG feed-through feature that facilitates the
implementation of the RETA solution, eliminating the need of an extra cable between the
Node B and the antenna for carrying the RETA signals. The AISG TMA includes a
receiver amplifier on each downlink path. In addition, the AISG TMA acts as an AISG
LOC, and provides AISG RS485 connectivity to the other ALDs (mainly RET antenna).
The AISG TMA is a dual-mode TMA, that can be used:
In AISG mode
In standard mode
The choice between the two modes is done at OMC, through the TmaAccessType
parameter:
TmaAccessType = tmaMix for AISG mode
TmaAccessType = tmaUmtsonly for standard mode
The AISG TMA is managed as a passive component by the TRDU. The AISG TMA is
active in reception only.
Hardware description
The AISG TMA hardware consists of the following components:
A pole fixing system
An AISG TMA module
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-91
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description AISG Tower Mounted Amplifier (AISG TMA)
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
AISG TMA module
The AISG TMA is composed of the following devices:
A pass-band filter
A Low Noise Amplifier (LNA)
All the external RF connectors are standard female 7/16 connectors.
The AISG TMA provides the following connectors:
The "ANT 0" and "ANT 1" connectors, which allow connection to the antennas (Main
and Diversity).
The "NodeB 0" and "NodeB 1" connectors, which allow connection to the Node B.
The AISG connector, which provides connection to the RCU through an AISG cable.
DC power
AISG TMA in non AISG mode: +12 V dual branches power supply (from TRDU antenna
connector).
AISG TMA in AISG mode: +24 V single branch power supply (from main TRDU
antenna connector) delivered by the CCU.
TMA alarms
The TMA alarms are monitored by the TRDUs. If the TMA is faulty, this is reported to
the OMC as a TRDU fault and the impacted cells are notified to the RNC.
TMA alarms in AISG mode are monitored by the AISG CCU and sent through site LAN
interface.
PRELIMINARY
....................................................................................................................................................................................................................................
4-92 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Remote Electrical Tilt Automatic (RETA)
PRELIMINARY
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
Main functions
The RETA feature allows to adjust remotely the antenna tilt from the OMC (over IP),
through the Node B.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-93
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Remote Electrical Tilt Automatic (RETA)
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
The CCU front panel provides the following connectors:
One "ALARM INTERFACE" connector (9-pin D-SUB female connector), used for
connection to the IEAM front panel ("ALARM 2" connector) (the CCU alarms can be
collect by connection to eAMi front panel (1st external alarm RJ 45 connector))
One "RS232" connector (9-pin D-SUB male connector), used for connection to a
modem or a laptop
One "ETHERNET" connector (RJ-45 type connector), used for connection to the
xCCM-U/eCCM-U board ("Port 1")
Three 8-pin circular female connectors, used for AISG connection to the TRDUs
("AISG IN" connector on TRDU front panel)
One DC power connector, used for connection to the TRDU ICO module ("J2 AUX"
connector on TRDU ICO front panel)
One AC power supply interface
The configuration management, fault management and control of the CCU are performed
through the IP network, enabling operation at OMC level.
The RETA option is AISG-compliant.
....................................................................................................................................................................................................................................
4-94 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Remote Electrical Tilt Automatic (RETA)
PRELIMINARY
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
RETA kits
The proposed kits are the following:
RETA Base AISG
This kit is mandatory regardless of the configuration requirements. It is required to
install the CCU in the 9944 Smart S18K 6U space dedicated to optional equipment. It
includes:
One CCU module
A complete set of items required for installing the CCU in the dedicated 6U space
Power and interconnection cables
PRELIMINARY
Items required for interconnection with the TRDU for a three-sector configuration
Cables required for site LAN connection between the CCU and the
xCCM-U/eCCM-U
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-95
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Remote Electrical Tilt Automatic (RETA)
9944 Smart S18K other equipment
....................................................................................................................................................................................................................................
This option requires the use of the following modules:
TRDU
AISG TMA
RETA Line Extension
This kit allows to connect the RCU to the TMA, for a configuration with one Xpolar
antenna per sector. It includes:
One RCU module
One cable to connect the RCU to the TMA
One kit is required per sector. One kit is required for an omni-directional
configuration, two kits for a two-sector configuration, and three kits are required for a
three-sector configuration.
PRELIMINARY
....................................................................................................................................................................................................................................
4-96 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
9944 Smart S18K hardware description Physical characteristics of the 9944 Smart S18K other
PRELIMINARY
9944 Smart S18K other equipment equipment
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 4-97
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY 9944 Smart S18K hardware description Physical characteristics of the 9944 Smart S18K other
equipment
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
4-98 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013
PRELIMINARY
5 Using the TIL tool
5
Overview
Purpose
This chapter describes the Local Installation Terminal (TIL).
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9944 Smart S18K Alcatel-Lucent Proprietary 5-1
9YZ-03450-4201-DEZZA UA08.1 Use pursuant to applicable agreements
Issue 0.04 January 2013
PRELIMINARY Using the TIL tool Using the TIL tool
....................................................................................................................................................................................................................................
TIL functions
The TIL provides the following functions:
Displays the existing hardware of the equipment
Automatically displays new hardware
Basic maintenance and test capabilities for equipment modules
Saves reports (alarm, test reports, etc.) on a laptop
Retrieves the hardware and software module configuration
Configures commissioning parameters
....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9944 Smart S18K
Use pursuant to applicable agreements 9YZ-03450-4201-DEZZA UA08.1
Issue 0.04 January 2013