Beruflich Dokumente
Kultur Dokumente
GloAc AMRDNRATEACSWCH
GloAc TTRUEQFORCED
GloAc FORCQUESWIAMR
GloAc FORCQUESWICS64
GloAc TTRUEQ
GloAc QLENGTH
GloAc TTRUEQRELOC
Hspa RNCFDPCHSUPIND
Hspa DCHSDSCHSPTIND
Hspa RNCMIMO64QAMIND
Hspa RNCEFDPCHSUPIND
Hspa POEHICHNOSERRL2
Hspa HSGBRLIMITSWI
Hspa CODEREASSPRD
Hspa RNCMIMOIND
Hspa POERGCHSERRLS2
Hspa RNCENL2IND
Hspa RNC64QAMIND
Hspa POERGCHSERRLS10
Hspa NRTDTXDRXSWCH
Hspa RNCDCMIMOSUPIND
Hspa POEHICHSERRLS2
Hspa CODEREASSIND
Hspa EAGCHPOUPTSWCH
Hspa NVHSSCLESSSWCH
Hspa POERGCHNONSERRLS
Hspa POEHICHSERRLS10
Hspa RTDTXDRXSWCH
Hspa RLCSIZESUPTTYPE
Hspa HSSCLESSSWCH
Hspa ULRLCSIZESPTTYPE
Hspa DTXDRXSWCH
Hspa POEHICHNOSERRL10
QosSeg MAXDLDPCHPO
QosSeg BPSEGNUM
QosSeg DLRATEADJLEV
QosSeg BPTHRESH
QosSeg DLRATEADJLEVNUM
QosSeg ULRATEADJLEVNUM
QosSeg ARPSEGNUM
QosSeg HSPAEQUHSUSER
QosSeg EDCHNORMBITRATE
QosSeg ARPTHRESH
QosSeg HSNORMBITRATE
QosSeg ULRATEADJLEV
QosSeg THPSEGNUM
QosSeg DLNORMBITRATE
QosSeg ULNORMBITRATE
QosSeg THPTHRESH
QosSeg MAXULDPCHPO
cnInfo ATTINDCS
cnInfo NMOPS
cnInfo CNDOMAIN
cnInfo KPS
cnInfo KCS
cnInfo T3212CS
cnInfo MBMSMODPRDCOEFF
drbc SRBONEDCHSWCH
drbc AMROVERHSPASWCH
drbc TOFTIMESTHR
drbc DELTANUME4B0THD
drbc DTCPEBTHD
drbc INITIALRATEUL
drbc DLPSRATELMTHIGHC
drbc DCHE4BTHD
drbc SCHQSWCH
drbc PCHHOLDTIMETHR
drbc PCHSWCH
drbc DLPSRATELMTLOWC
drbc FACHSWCH
drbc FTOPCHTHD
drbc DTOPCHTHD
drbc ULPWRDASF
drbc DRBCSWCH
drbc ETTITRAFFVOLSWCH
drbc FTOIDLETHD
drbc DTCPEATHD
drbc ULPSRATELMTHIGHC
drbc ULPSRATELMTLOWC
drbc CRATETHRD
drbc ETTIEBTHD
drbc ETTIEATHD
drbc DCHADJRATESWCH
drbc DLPWRDASF
drbc FACHE4ATHD
drbc IBCHQSWCH
drbc INITIALRATEDL
drbc RFACH
drbc DCHE4ATHD
drbc DXHSBO0E4BTHD
drbc RRACH
drbc DCHSIG68SWCH
drbc CCHQSWCH
drbc DTOIDLETHD
iuCnst NREPEATRESRST
iuCnst TRAFC
iuCnst TRELOCOVERALL
iuCnst TIGOR
iuCnst TINTR
iuCnst TRESETDELAY
iuCnst NREPEATRST
iuCnst TRELOCPREP
iuCnst TRESETWAIT
iuCnst TDATAFWD
iuCnst TRATC
iuCnst TQUEUING
rncBRnc ACKNACKENCIND
rncBRnc LCSMETHOD
rncBRnc CS64RBMODESWCH
rncBRnc NBRCELLMONSUPIND
rncBRnc NACCSUPPIND
rncBRnc BASEDIMSIHOIND
rncBRnc PSINTERSYSHOSUPP
rncBRnc PSCONVTRASUP
rncBRnc LDBSDINTSYSHOIND
rncBRnc WAMRSUPIND
rncBRnc FOURECHALLOWED
rncBRnc PSSIGFORIMSIND
rncBRnc PTPOVERHS
rncBRnc DTMSUPPIND
rncBRnc SERVBASEDHOIND
rncBRnc R99NRTETRAHOSWCH
rncBRnc HSUPARATHOSWCH
rncBRnc R99NRTIFHOSWCH
rncBRnc GRESPARA18
rncBRnc GRESPARA19
rncBRnc FASTRECFGSPTIND
rncBRnc GRESPARA9
rncBRnc R99RTEUTRAHOSWCH
rncBRnc HSDPARATHOSWCH
rncBRnc AMRIFHOSWCH
rncBRnc GRESPARA20
rncBRnc AMRRATHOSWCH
rncBRnc HSUPAEUTRAHOSWCH
rncBRnc HSDPAIFHOSWCH
rncBRnc R99RTIFHOSWCH
rncBRnc HSUPAIFHOSWCH
rncBRnc DYNAUPDTPO2STCH
rncBRnc R99RTRATHOSWCH
rncBRnc GRESPARA11
rncBRnc GRESPARA5
rncBRnc GRESPARA10
rncBRnc GRESPARA6
rncBRnc GRESPARA13
rncBRnc R99NRTRATHOSWCH
rncBRnc GRESPARA7
rncBRnc GRESPARA12
rncBRnc GRESPARA8
rncBRnc GRESPARA15
rncBRnc GRESPARA1
rncBRnc GRESPARA14
rncBRnc GRESPARA2
rncBRnc GRESPARA17
rncBRnc GRESPARA3
rncBRnc GRESPARA16
rncBRnc GRESPARA4
rncBRnc HSDPAEUTRAHOSWCH
rncFunction MBMSRATESWITCH
rncFunction EMGCALLRDTSWITCH
rncFunction SHAREDNETMODE
rncFunction PSNRIBITNUM
rncFunction CSNRIBITNUM
rncFunction LOCMODESWCH
rncFunction VIPLOADCONSWCH
rncFunction MULTICASTSUPIND
rncFunction VIPSPECFREQSWCH
rncFunction MBMSIURSUPIND
rncFunction GPSINFOROOT
rncFunction IUULINSEQDLVIND
rncFunction WHTLSTSWITCH
rncFunction CBSSWITCH
rncFunction RNCLCSOVERIURSW
rncFunction EBROADCASTSUPIND
rncFunction INITRRCONDCH
rncFunction VIPDLARFCNIND
rncFunction UPDASIB3CELNUM
rncFunction UPUDRECFGTIMER
rncFunction MEASBALTIMER
rncFunction T1D
rncFunction ECN0THRADDNRLSHO
rncFunction INTERNACKPWROFST
rncFunction SIRUPADDSTEP
rncFunction CELCHGFASTCFGIND
rncFunction INTERCQIPWROFST
rncFunction HARQRVCONFIG
rncFunction VLACPAINGIND
rncFunction BWOVLDRELUENUM
rncFunction MAXDHSRATE
rncFunction T4STPIFMEAACTRAT
rncFunction RSCPTHRADDNRLSHO
rncFunction TWAITCONTEXTREQ
rncFunction HSDPACMASSOMODE
rncFunction PARALLELRRCSETUP
rncFunction ULEFACHSF
rncFunction CEDCHMAXRLCSIZE
rncFunction T321
rncFunction CEDCHMAXRETRTTI2
rncFunction NRETRAN
rncFunction CDTMROVDTHD
rncFunction DNUDRECFGTIMER
rncFunction MRUEMEASRPTTRMOD
rncFunction CEDCHMULTISWI
rncFunction RABMEABALSTASWCH
rncFunction TRESNDMEACTRLREL
rncFunction MRUEMEASRPTINT
rncFunction HEARTBEATUEVER
rncFunction TIURELDELAY
rncFunction PCHTOAWS
rncFunction DCREDIRECTSTASW
rncFunction GRESPARA60
rncFunction BERTARGADPTIMER
rncFunction WAITRBCOMPTIMER
rncFunction IURPWRCTLREQSWCH
rncFunction CMINULPDUSIZE
rncFunction PLMNSELECTMETHOD
rncFunction INTERACKPWROFST
rncFunction NONCMAXPDUSIZE
rncFunction HEARTBEATFREQ
rncFunction POWHITELISTUSER
rncFunction CODEUPTPRDUNIT
rncFunction VALIDTIMTBCOVPRD
rncFunction DTOHSDELAYTHR
rncFunction MINBERTARGET
rncFunction MAXRATEWITHNVHS
rncFunction INTERRATUPVER
rncFunction TWAITDATAFWD
rncFunction GRESPARA50
rncFunction RRCSETUPRETRANUM
rncFunction MRUEMEASTYPESWIT
rncFunction ROUTETYPEUEBASED
rncFunction GRESPARA51
rncFunction GRESPARA52
rncFunction GRESPARA53
rncFunction RXBURSTLENGTH
rncFunction ONLYDNONHB
rncFunction TRRCCONSETUPEXP
rncFunction GRESPARA54
rncFunction TWAITRELCMD
rncFunction GRESPARA55
rncFunction BLERADJUSTSWITCH
rncFunction GRESPARA56
rncFunction GRESPARA57
rncFunction CMAXPDUSIZE
rncFunction GRESPARA58
rncFunction PCHTOAWE
rncFunction GRESPARA59
rncFunction MRUEPRDLOCMODE
rncFunction TRRCSETUPRETRAN
rncFunction DRXCYCLELENGTH
rncFunction AMRGBRRESIND
rncFunction MRSERVICETYPE
rncFunction GRESPARA49
rncFunction GRESPARA48
rncFunction ETTICOMEDCH
rncFunction GRESPARA47
rncFunction GRESPARA46
rncFunction GRESPARA45
rncFunction GRESPARA44
rncFunction GRESPARA43
rncFunction GRESPARA42
rncFunction GRESPARA41
rncFunction VIPINFOREQPRD
rncFunction TWAITCELUPUUEXP
rncFunction CELLLDINFOVLDTIM
rncFunction VIPESTNTFSWITCH
rncFunction TCNQUERY
rncFunction DROPFORVIPSWITCH
rncFunction KUTRAN
rncFunction TWAITRLRESTORE
rncFunction CODEUPTPRD
rncFunction ULLCHTYPEIND
rncFunction HSDSCHTOTPWRMETH
rncFunction CEDCHHARQPOTTI2
rncFunction COVERMEABALSWCH
rncFunction NONCMINULPDUSIZE
rncFunction HSUPACMASSOMODE
rncFunction MAXBERTARGET
rncFunction MAXCSDELAY
rncFunction CSRRCONFACHSWCH
rncFunction CEDCHMAXRETRTTI10
rncFunction TRBRECFGCMPDTOF
rncFunction CEDCHMINRLCSIZE
rncFunction TWAITCELUPRLDACT
rncFunction CEDCHHARQPOTTI10
rncFunction HAPPYBITDELCEDCH
rncFunction N308
rncFunction CMAXULPDUSIZE
rncFunction NONCMAXULPDUSIZE
rncFunction FACHTOAWS
rncFunction VIPESTNTFNBRPRIO
rncFunction FACHTOAWE
rncFunction INTRARATUPVER
rncFunction IURECNODELTA
rncFunction MRUEINICALLLOCMODE
rncFunction TWAITACTSETUPCMP
rncFunction UPDSIB3CELNT
rncFunction MRUELOCMEARPTINT
rncFunction UEDRXIND
rncLocRnc RNCSRVCCSW
rncLocRnc CDTSWITCH
rncLocRnc GSMLRANGE
rncLocRnc MRSWITCH
rncLocRnc PSL2USWCHBYCS
rncLocRnc GSMURANGE
rncLocRnc CSNULLNRI
rncLocRnc AMRRNCADJUST
rncLocRnc LUARFCN
rncLocRnc PSNULLNRI
rncLocRnc FDDFREQRNGNUM
rncLocRnc RNCPSHOLTESW
rncLocRnc INTEGRITYALG
rncLocRnc ENCRYALG
rncLocRnc QOSNEGRENEGSWI
rncLocRnc GSMBARANGENUM
rncLocRnc DRBCSCENE
rncLocRnc UUARFCN
rncLocRnc CSPLUSPSSWCH
rncLocRnc SERVHOIND
rncLocRnc AMRWBMODE3USETAG
rncLocRnc NAMRINITIALRATE
rncLocRnc PSRTSERVHOSTRA
rncLocRnc AMRWBMODE2USETAG
rncLocRnc AMRNBMODE2USETAG
rncLocRnc AMRSERVHOSTRA
rncLocRnc AMRWBMODE7USETAG
rncLocRnc AMRWBMODE4USETAG
rncLocRnc AMRNBMODE0USETAG
rncLocRnc AMRWBMODE5USETAG
rncLocRnc CDTIMEIACQSWITCH
rncLocRnc AMRWBMODE1USETAG
rncLocRnc AMRNBMODE3USETAG
rncLocRnc AMRNBMODE1USETAG
rncLocRnc AMRWBMODE6USETAG
rncLocRnc NEGGBRLEVNUM
rncLocRnc COMPMDCFGSTRA
rncLocRnc DLLOWLIMNEGGBR
rncLocRnc WAMRINITIALRATE
rncLocRnc TNNSF
rncLocRnc AMRNBMODE7USETAG
rncLocRnc HOTOGSMPENTIMER
rncLocRnc ULLOWLIMNEGGBR
rncLocRnc AMRNBMODE4USETAG
rncLocRnc AMRWBMODE8USETAG
rncLocRnc CS64SERVHOSTRA
rncLocRnc R6MULRABRCFGMETH
rncLocRnc AMRNBMODE6USETAG
rncLocRnc RLREFTIMEAJTSWIT
rncLocRnc SERVHOCOMSTRA
rncLocRnc PSNRTSERVHOSTRA
rncLocRnc AMRWBMODE0USETAG
rncLocRnc AMRNBMODE5USETAG
ueCnst T309
ueCnst T323
ueCnst T314
ueCnst T305
ueCnst T315
ueCnst T307
ueCnst T313
ueCnst T308
ueCnst T312IDLE
ueCnst T302
ueCnst T316
ueCnst T304
ueCnst T300
ueCnst N302
ueCnst N315
ueCnst T312CONNECTED
ueCnst N312IDLE
ueCnst N300
ueCnst T323SWCH
ueCnst N304
ueCnst N313
ueCnst N312CONNECTED
nodeB PLMNNUM
nodeB TIMEDELAY
nodeB HSSHARMETHOD
nodeB MNC4RANSHARING
nodeB NODEBTYPE
nodeB MCC4RANSHARING
nodeB MINCEPERCENT
nodeB TIPRELLINKPRO
nodeB DIVCONTRLFIELD
nodeB ADJTYPE
nodeB TATMRELLINKPRO
nodeB TWAITNBREACH
nodeB AUDITTIMER
nodeB HSSHARUPTPRD
nodeB TIMEDELAYJITTER
nodeB SUPTCGTDETIND
utranCell CELLINDIVOFFSET
utranCell CGTCTLPRIINDEX
utranCell MULMDUTRANCELIND
utranCell SIB12IND
utranCell LATITUDE
utranCell ACCESSPERCENT
utranCell STTDSUPTIND
utranCell INNERANGLE
utranCell PSCHPWR
utranCell ANTETYPE
utranCell LOADSCENE
utranCell HSPASPTMETH
utranCell TRFPCINDEX
utranCell PICHPWR
utranCell RNCID
utranCell PSBARACNUM
utranCell URANUM
utranCell MNC
utranCell RAC
utranCell DIVPCINDEX
utranCell CELLDESCRIPTYPE
utranCell OCNSCODE
utranCell SCCPCHCFGSCENE
utranCell DCHSDSCHSUPPTIND
utranCell USEOFHCS
utranCell TCELL
utranCell PRIMSCRACODE
utranCell GARPTTYPE
utranCell IMPULL2SUPTIND
utranCell PLMNNUM
utranCell MAXDLTXPWR
utranCell LATITUDESIGN
utranCell CELMIMO64QAMIND
utranCell UNCERTCODE
utranCell CELLRADIUS
utranCell CELLRADIUSSCENE
utranCell TRFCATRATMIDX
utranCell DUARFCN
utranCell SECTORID
utranCell FDPCHSUPTIND
utranCell CSBARACNUM
utranCell URA
utranCell CLASSZONEIND
utranCell PRIREDIRECTRAT
utranCell SSCHPWR
utranCell LAC
utranCell ALTITUDEACC
utranCell SACPC
utranCell POLYLATITUDE
utranCell CELLDCMIMOSUPIND
utranCell MIMOSUPTIND
utranCell SCHTSTDIND
utranCell PREFTRAFTYPE
utranCell POLYLONGITUDE
utranCell ANTELONGITUDE
utranCell PCCPCHSTTDIND
utranCell VAMSUPIND
utranCell SACB
utranCell LONGITUDE
utranCell PCPICHPWR
utranCell BPRIACINDEX
utranCell HOCELSELSCENE
utranCell BCHPWR
utranCell ANTELATITUDESIGN
utranCell CSACBARREDOMCR
utranCell PSACBARREDOMCR
utranCell CSDSARSWH
utranCell ANTEALTITUDEDIR
utranCell MIMOPILOTMODE
utranCell POLYLATITUDESIGN
utranCell EFDPCHSUPIND
utranCell CELLSCEN
utranCell ULBLERHOSWCH
utranCell PSDSARPOLLINGSWH
utranCell AICHPWR
utranCell SUPT64QAMIND
utranCell CS64SWITCH
utranCell COMMONPLMNIND
utranCell PCPICHTXDIVIND
utranCell CLM1SUPTIND
utranCell LOADBALANCESCENE
utranCell CELLTYPE
utranCell EFACHSPPTIND
utranCell IMPDLL2SUPTIND
utranCell MCC
utranCell SCENARIOTYPE
utranCell PCHPWR
utranCell BGNOISCENE
utranCell HCSPRIO
utranCell SUPTMULUSDETIND
utranCell ULEFACHSUPPORT
utranCell CSDSARPOLLINGSWH
utranCell SCHPRIINDEX
utranCell NODEBNO
utranCell SACBPRE
utranCell TWAIT
utranCell MBMSSUPTIND
utranCell POLYGONPOINTNUM
utranCell ANTELATITUDE
utranCell HSDSTAT
utranCell DLPWRHOSWCH
utranCell STTDMIMOBINDIND
utranCell MODULE
utranCell ALTITUDE
utranCell CLOSEFREFUNSWIT
utranCell TRFCATINTRAMIDX
utranCell UNCERTALTITUDE
utranCell OFFSETANGLE
utranCell LCID
utranCell ANTEALTITUDE
utranCell SCPICHSUPIND
utranCell HSUSTAT
utranCell RADIOCAPACITY
utranCell OCNSCODENUMBER
utranCell TUTRANGPSSPTIND
utranCell ULPWRHOSWCH
utranCell PAGINGLOCABARSWH
utranCell LDCTLPRIINDEX
utranCell ALTITUDEDIR
utranCell TRFCATINTERMIDX
utranCell CPCSUPTIND
utranCell PSDSARSWH
utranCell MIMOIND
utranCell TTI2MSSUPTIND
utranCell UUARFCN
utranCell CONFIDENCE
utranCell FREQBANDIND
utranCell MBMSSTAT
utranCell EDCHNUMLEV
utranCell FRECLSOPNTRIGTM
utranCell DLCACSWITCH
utranCell EFACHBANDWIDTH
utranCell DRXONFACHIND
utranCell RRCSIGUSRNUMTHR
utranCell NRTMAXRATEEDCH
utranCell INTRAMEASQUAN
utranCell ADDNRLSHOSWCH
utranCell STARTTIMETOCLSF
utranCell PSREESTSWITCH
utranCell PAGINGSENDTIMES
utranCell INTRATHOMTH
utranCell PATHLOSS
utranCell PCPIPWRDNTMWIN
utranCell CRESPARA2
utranCell CRESPARA1
utranCell CRESPARA4
utranCell CRESPARA3
utranCell CRESPARA6
utranCell CRESPARA5
utranCell CRESPARA8
utranCell CRESPARA7
utranCell CRESPARA9
utranCell NRTMAXDLRATEDCH
utranCell DPCCHPCPLEN
utranCell RRCRDTSWCH
utranCell RSCPQUALTHRD
utranCell MAXRATEMD
utranCell PORABHARDHO
utranCell CELLBARACSWH
utranCell DLCONTROLEDMBR
utranCell INTERHOTACTIC
utranCell CELLBARPOLLINGSWH
utranCell CRESPARA20
utranCell SIB4IND
utranCell CRESPARA19
utranCell CRESPARA18
utranCell MRCELLMEASSWIT
utranCell CRESPARA17
utranCell CRESPARA16
utranCell CRESPARA15
utranCell CRESPARA14
utranCell DETSETHOSWCH
utranCell DLTPCN
utranCell PCCPCHINFSIB6PRE
utranCell PSNUMTHRD1
utranCell PCPIPWRDNSTEP
utranCell PSNUMTHRD2
utranCell CELAVASUBCHA
utranCell CRESPARA10
utranCell CSNUMTHRD2
utranCell CRESPARA11
utranCell CSNUMTHRD1
utranCell RATHOTACTIC
utranCell CRESPARA12
utranCell CRESPARA13
utranCell NONINTRAMEASQUAN
utranCell CCHFACTOR
utranCell POSETUP
utranCell CELLBARACNUM
utranCell BARINTERVAL
utranCell ORIBCKNOISE
utranCell DEFAULEDCHNUMLEV
utranCell AMRULLDTHRD
utranCell CHOSTRAMULRATHO
utranCell ULCTRLMBRSWITCH
utranCell SOFTHOMTH
utranCell SERVHOSWCH
utranCell SIMCOMPUSERNUM
utranCell POSRBHARDHO
utranCell VIRTUALLAC
utranCell MRCELMRPTINTCOEF
utranCell DLEFACHUSERNUM
utranCell MRUEMEASSWIT
utranCell POREESTABLISH
utranCell ULCACSWITCH
utranCell INTERHOMTH
utranCell BCKNOISEADJSWH
utranCell COVERPRD
utranCell RTMAXRATEEDCH
utranCell TRLFAILURE
utranCell AMRDLLDTHRD
utranCell SRBDELAY
utranCell HSUPAADATRANSWCH
utranCell ENDTIMETOCLSF
utranCell ECNOQUALTHRD
utranCell NUMOUTSYNCIND
utranCell SIB7ORIGINATOR
utranCell POSOFTHO
utranCell CSREESTSWITCH
utranCell UENUMTHRESHCLS
utranCell IFORRATHOSWCH
utranCell FORBTIMAFTOPNF
utranCell NRTMAXULRATEDCH
utranCell PCPIPWRDNSTEPTM
utranCell ABSPRIRESELSWCH
utranCell CPICHECN0
utranCell RTMAXULRATEDCH
utranCell SIB6IND
utranCell OPENFREALG
utranCell REFSFLAYER
utranCell UL16QAMSWI
utranCell RTMAXDLRATEDCH
utranCell NUMINSYNCIND
utranCell ULCONTROLEDMBR
utranCell DLCTRLMBRSWITCH
utranCell PRACHSIB6PRE
CHspa MINNUMOFHSPDSCH
CHspa NUMOFERGHICH
CHspa EDCHTRAFLIMIT
CHspa NUMOFEAGCH
CHspa MAXNUMOFHSPDSCH
CHspa NUMOFHSPDSCH
CHspa HSDSCHTRAFLIMIT
CHspa DEDICOMEAGCHSWI
CHspa CODEUPTHYA
CHspa MAXHSPAPWRRTO
CHspa HSSHAREIND
CHspa NUMOFHSSCCH
CHspa CEDCHUSERNUM
CHspa DPCHCODEHY
CHspa HSPAPWRRATIO
CHspa NSERVTOTOTALPWR
CHspa HSPDSCHBITRATE
CHspa IURCDREASSDROP
CHspa MINHSPAPWRRTO
CHspa HSNBASSIND
CHspa MAXRTWP
CHspa CHSGBRRESLMTIDX
CelSel TCRMAXHYST
CelSel DLTAQRXLEVMINPR
CelSel SINTRASEARCHPRE
CelSel QQUALMIN
CelSel SINTERSEARCHPRE
CelSel OTHERRATINFOPRE
CelSel NOHCSTCRMAXHYST
CelSel NCR
CelSel SSEARCHRAT
CelSel QQUALMINOFFSET
CelSel OPERATORUSEIND
CelSel QHYST2SPCH
CelSel TRESELECTIONPCH
CelSel QQULMNOFFSTPRE
CelSel INTERRATSF
CelSel TRESELECTIONFACH
CelSel QRXLVMNOFFSTPRE
CelSel HCSSRVCELINFOPRE
CelSel CELLRSVEXT
CelSel CELLBARREDIND
CelSel QHCSRSCP
CelSel QHYST2S
CelSel DEFSIBSUPTSWCH
CelSel SSEARCHHCSPRE
CelSel SPSF
CelSel INTERFREQSFPRE
CelSel QHYST2SFACH
CelSel QHYST1SFACH
CelSel QRXLEVMINOFFSET
CelSel QUALMEAS
CelSel QRXLEVMIN
CelSel TBARRED
CelSel INTERRATSFPRE
CelSel NOHCSTCRMAX
CelSel SSEARCHHCS
CelSel DLTAQRXLEVMIN
CelSel QHYST1S
CelSel SHCSRAT
CelSel SINTERSEARCH
CelSel INFREQRESELIND
CelSel SHCSRATPRE
CelSel TRESELECTION
CelSel NOHCSNCR
CelSel QHYST1SPCH
CelSel SINTRASEARCH
CelSel SLIMITRAT
CelSel QHCSECNO
CelSel SPSFPRE
CelSel INTRARPTQSIB3
CelSel ACBARREDOMCR
CelSel INTERFREQSF
CelSel TCRMAX
PriSel EUTRANHIGHTHRES2
PriSel QQUALMINFDD
PriSel EUTRANLOWTHRES2
PriSel EUTRANINTERFNUM
PriSel GERANHIGHTHRESH
PriSel GERANPRIORITY
PriSel UTRANHIGHTHRESH
PriSel EUTRANHIGHTHRESH
PriSel UTRANLOWTHRESH
PriSel QRXLEVMINGSM
PriSel QRXLEVMINEUTRA
PriSel UTRANINTERFNUM
PriSel EUTRANLOWTHRESH
PriSel EUTRANPRIORITY
PriSel THRESHRSRQIND
PriSel UTRANPRIORITY
PriSel QQUALMINEUTRA
PriSel UTRANUARFCN
PriSel QRXLEVMINFDD
PriSel GSMBANDINDICATOR
PriSel GSMCELLGROUPNUM
PriSel ALLOWMEASBAND
PriSel SERVCELPRIORITY
PriSel STARTARFCN
PriSel GERANLOWTHRESH
PriSel THRESHSERVINGLOW
PriSel DLEARFCN
PriSel SPRIORITYSEARCH1
PriSel SPRIORITYSEARCH2
PriSel THRESSERVINGLOW2
LdCtrl DLDECRATESW
LdCtrl MAXNUMUEOFDECRAT
LdCtrl ULFORCEHANDOFFSW
LdCtrl NODEBSAFETHR
LdCtrl ULMAXDRPURNUM
LdCtrl FORCERABTOFASWIT
LdCtrl DLOVERLD
LdCtrl DLMAXDRPURNUM
LdCtrl ULHIGHLD
LdCtrl DLHIGHLD
LdCtrl FORCEDRABRELSWIT
LdCtrl MAXGBRDECNUM
LdCtrl DLDROPSW
LdCtrl HSDSOVERLDTHR
LdCtrl DLALRMLD
LdCtrl SWITCHTOFACH
LdCtrl NFACH
LdCtrl ULMAXFORHONUM
LdCtrl DLFORCEHANDOFFSW
LdCtrl ULDECRATESW
LdCtrl DECGBRSW
LdCtrl ULDROPSW
LdCtrl ULALRMLD
LdCtrl DLSERIOUSOVERLD
LdCtrl FORCEDHOSWIT
LdCtrl ULOVERLD
LdCtrl ULSERIOUSOVERLD
LdCtrl DLMAXFORHONUM
LdCtrl DLDNMAXSTG
LdCtrl HSDSRECOVERTHR
LdCtrl ULDNMAXSTG
LdCtrl DLADJUSTMFPSW
LdCtrl AGLLDDEC
LdCtrl REQUIREDRDSWIT
Prach PERMITMAXASC
Prach DYNPSTLEVELINIT
Prach PSFNUM
Prach PRACHTYPE
Prach CONSTVAL
Prach ASUBCHNUM
Prach MAXRACHTXPWR
Prach AVAILSUBCHANNUM
Prach ASIGENDIDX
Prach PREAMTHS
Prach SIB5ORSIB6
Prach ASIGSTIDX
Prach RACHCTCID
Prach MAXPREAMRETRANS
Prach SIGNATURE
Prach PSF
Prach MMAX
Prach PREAMSCRACODE
Prach PRSTEP
Prach AC2ASCMAP
CUeInt PSEVTMEASTP1
CUeInt HOEVTMEASTP
CUeInt PRDMEASRTT
CUeInt EVTMEASTP1
CUeInt EVTMEASRTT2
CUeInt EVTMEASRTT1
CUeTrv DRBCFACHUP
CUeTrv DRBCDCHUEPRD
CUeTrv DRBCRACHUEEVT
CUeTrv DRBCEDCHUPTHPT
CUeTrv ETTIUPTHPT
CUeTrv DRBCCFACHHSUP
CUeTrv DRBCRACHUEPRD
CUeTrv DRBCSHSUP
CUeTrv DRBCDCHUP
CUeTrv DRBCCFACHEDCHUP
CUeTrv DRBCIBHSUP
CUeTrv DRBCDCHUEEVT
ExtHspa EDPCCHPOTTI2
ExtHspa EDCHREFPO
ExtHspa CQICYCLE
ExtHspa ACKPWROFFSET
ExtHspa SCHEINFOPOTTI2
ExtHspa TPCERRTARGET
ExtHspa CQIREPFACTOR
ExtHspa CQIPWROFFSET
ExtHspa EDPCCHPOTTI10
ExtHspa NACKPWROFFSET
ExtHspa ANACKREPFACTOR
ExtHspa SCHEINFOPOTTI10
utranRelation NRNCID
utranRelation NCID
utranRelation NCTOSELFPHYRNC
utranRelation STATEMODE
utranRelation MEASPRIO
utranRelation SIB11ORSIB11BIS
utranRelation CID
utranRelation TEMPOFFSET2SIB11
utranRelation USEOFHCS
utranRelation TEMPOFFSET1SIB11
utranRelation PENALTYTIMESIB11
utranRelation SHARECOVER
utranRelation CELLINDIVOFFSET
utranRelation TEMPOFFSET2SIB12
utranRelation QHCSRSCPSIB11
utranRelation TEMPOFFSET1SIB12
utranRelation PENALTYTIMESIB12
utranRelation QOFFSET2SNSIB12
utranRelation QOFFSET1SNSIB11
utranRelation QOFFSET1SNSIB12
utranRelation QHCSRSCPSIB12
utranRelation QHCSECN0SIB11
utranRelation QHCSECN0SIB12
utranRelation QOFFSET2SNSIB11
gsmRelation NCI
gsmRelation NLAC
gsmRelation USEOFHCS
gsmRelation GSMSTATEMODE
gsmRelation NCTOSELFPHYRNC
gsmRelation MEASPRIO
gsmRelation SIB11ORSIB11BIS
gsmRelation GSMSHARECOVER
gsmRelation CID
gsmRelation TEMPOFFSET1SIB11
gsmRelation TEMPOFFSET1SIB12
gsmRelation PENALTYTIMESIB12
gsmRelation QHCSSIB12
gsmRelation QOFFSET1SNSIB11
gsmRelation QOFFSET1SNSIB12
gsmRelation PENALTYTIMESIB11
gsmRelation QHCSSIB11
Sccpch CPCID
Sccpch MAXFACHPWR
Sccpch CID
Sccpch STTDIND
Sccpch SIB5ORSIB6
Sccpch SCCPCHOFFSET
Sccpch PO3
Sccpch PO1
Sccpch SCCPCHUSAGE
Sccpch CPCID
Sccpch MAXFACHPWR
Sccpch CID
Sccpch STTDIND
Sccpch SIB5ORSIB6
Sccpch SCCPCHOFFSET
Sccpch PO3
Sccpch PO1
Sccpch SCCPCHUSAGE
CelMPO APPHSDPAEIND
CelMPO MEASPWROFFSET
CelMPO APPHSDPAEIND
CelMPO MEASPWROFFSET
CelMPO APPHSDPAEIND
CelMPO MEASPWROFFSET
CelMPO APPHSDPAEIND
CelMPO MEASPWROFFSET
CelMPO APPHSDPAEIND
CelMPO MEASPWROFFSET
CelMPO APPHSDPAEIND
CelMPO MEASPWROFFSET
CelMPO APPHSDPAEIND
CelMPO MEASPWROFFSET
CelMPO APPHSDPAEIND
CelMPO MEASPWROFFSET
EUtranCell ENODEBID
EUtranCell EUTRANCID
EUtranCell EUTRANCELLTYPE
EUtranCell MNC
EUtranCell ULEARFCN
EUtranCell TAC
EUtranCell EUTRANMEASBAND
EUtranCell MNCBCDCODELEN
EUtranCell PHYEUTRANCID
EUtranCell DLEARFCN
EUtranCell MCC
EUtranCell ENODEBTYPE
QosIndex RESBWDINDEX
QosIndex TBTYPEINDEX
QosIndex MCC
QosIndex PROFILEINDEX
QosIndex MNC
QosIndex PLMNNUM
Parameter Long Name
Switch of AMR Traffic Re-admission after AMR Rate Decrease
Maximum Time in the True Queue when Service be Forced into Queue(s)
Forced Queue Switch for AMR Service
Forced Queue Switch for CS 64kbps service
Time of True Queue for Congested Service in RAB Setup Process(s)
True Queue Length
Time of True Queue for Congested Service Relocating into UTRAN(s)
RNC F-DPCH Support Indicator
Dual-Cell HS-DSCH Support Indication
RNC MIMO and DL64QAM Combined Capability Support Indicator
RNC Enhanced F-DPCH Support Indicator
Power Offset Relative to E-HICH in Single Link Condition for E-HICH of Non-serving RLS in Macro
Diversity Condition (2ms TTI)(dB)
Switch for Limiting HSDPA GBR Resource Consumption
DPCH Code Re-Assign Period(s)
RNC MIMO Support Indicator
Power Offset Relative to E-RGCH in Single Link Condition for E-RGCH of Serving RLS in Macro
Diversity Condition (2ms TTI)(dB)
RNC Downlink Enhanced Layer 2 Support Indicator
RNC 64QAM Support Indicator
Power Offset Relative to E-RGCH in Single Link Condition for E-RGCH of Serving RLS in Macro
Diversity Condition (10ms TTI)(dB)
DTX/DRX Switch for NRT
RNC DC+MIMO Support Indicator
Power Offset Relative to E-HICH in Single Link Condition for E-HICH of Serving RLS in Macro
Diversity Condition (2ms TTI)(dB)
DPCH Code Re-Assign Support Indicator
Dynamic Updating Switch of E-AGCH Power Offset
HS-SCCH Less Switch for Non-VoIP/AMR
Power Offset Relative to 10ms TTI E-RGCH in Single Link Condition for E-RGCH of Non-serving RLS
in Macro Diversity Condition(dB)
Power Offset Relative to E-HICH in Single Link Condition for E-HICH of Serving RLS in Macro
Diversity Condition (10ms TTI)(dB)
DTX/DRX Switch for Speech
Support Type of Downlink RLC Flexible PDU Size Format
HS-SCCH Less Switch
Support Type of Uplink RLC Flexible PDU Size Format
DTX/DRX Switch
Power Offset Relative to E-HICH in Single Link Condition for E-HICH of Non-serving RLS in Macro
Diversity Condition (10ms TTI)(dB)
Power Offset of the Maximum Downlink DPCH Showing Different Basic Priority(dB)
Basic Priority Segment Number
Downlink Rate Adjustment Level(kbps)
Basic Priority Segment Threshold
Downlink Rate Adjustment Level Number
Uplink Rate Adjustment Level Number
ARP Segment Number
Equivalent HSPA Users
E-DCH Uplink Nominal Bit Rate(kbps)
ARP Segment Threshold
HS-DSCH Downlink Nominal Bit Rate(kbps)
Uplink Rate Adjustment Level(kbps)
THP Segment Number
DCH Downlink Nominal Bit Rate(kbps)
DCH Uplink Nominal Bit Rate(kbps)
THP Segment Threshold
Power Offset of the Maximum Uplink DPCH Showing Different Basic Priority(dB)
IMSI Attach and Detach Indicator
Network Mode of Operation
CN Domain Supported
PS Domain DRX Cycle Length Coefficient
CS Domain DRX Cycle Length Coefficient
Event 4B Counter Threshold for CELL_FACH without DRX to PCH Shared by Uplink and Downlink
Event 4B Counter Threshold for CELL_DCH to PCH Shared by Uplink and Downlink
Switch for UL DCH Rate Adjustment Based on UE Transmission Power
DRBC Method Switch
Switch of E-TTI Switching Triggered by User Plane Throughput Measurement
Event 4B Counter Threshold for CELL_FACH without DRX to Idle Shared by Uplink and Downlink
Event 4A Counter Threshold for CELL_FACH to CELL_DCH Shared by Uplink and Downlink
Timer for Ignoring all OVERLOAD Messages or Signalling Point Congested Information(TigOR)(s)
Wait Timer for Adjusting Uplink and Downlink Reconfiguration by One Step Upward(100ms)
Wait Timer for Adjusting Uplink and Downlink Reconfiguration by One Step Downward(100ms)
Waiting Timer of SRNS for IU RELEASE COMMAND while PS service handover from 3G to 2G(100ms)
Wait Time for RADIO BEARER RECONFIGURATION COMPLETE when CELL_DCH to CELL_FACH(s)
Encryption Algorithm
Lower Limit of GBR for Downlink Services Used for QoS Negotiation/Renegotiation(kbps)
Waiting Time After Requesting Connection Establishment in Other System(eg. GSM) (T309)(s)
Waiting Time for Completion of Cell Update When Radio Link Fails and Radio Bearer(s) Associated
with T315 Exist(T315)(s)
Waiting Time for Cell Reselection After UE is out of Service(T307)(s)
Waiting Time After Sending RRC CONNECTION RELEASE COMPLETE Message in CELL_DCH
State(T308)(ms)
Waiting Time for Receiving"In Sync"from L1 in Idle Mode (T312 in Idle Mode)(s)
Waiting Time After UE Sending CELL/URA UPDATE Message(T302)(ms)
Waiting Time for Cell Selection/Reselection After UE is out of Service in CELL_PCH/URA_PCH
State(T316)(s)
Waiting Time After UE Sending UE CAPABILITY INFORMATIONMessage(T304)(ms)
Waiting Time After UE Sending RRC CONNECTION REQUEST Message(T300)
Maximum Number of Retransmissions of the CELL/URA UPDATE Message (N302)
Maximum Number of Successive "In Sync" Received from L1 During T313 is Activated ( N315)
Waiting Time for Receiving "In Sync" from L1 in Connected Mode(T312 in Connected Mode)(s)
Maximum Number of "In Sync" Received from L1 in Idle Mode (N312 in Idle Mode)
Maximum Number of "In Sync" Received from L1 in Connected Mode (N312 in Connected Mode)
Traffic PC Index
PICH Power(dB)
RNC Identity of UTRAN cell
Number of Barred AC in PS Domain
URA Number
Mobile Network Code
Routing Area Code
Diversity PC Index
Cell Description Type
Code Node Number with SF =128 for OCNS
SCCPCH Configuration Scene
Dual-Cell HS-DSCH Support Indication
Use of HCS
T_Cell
Cell Primary Scrambling Code
Geographical Area Report Type
Cell Uplink Enhanced Layer 2 Support Indicator
PLMN Number of Sharing the Cell
Cell Maximum Transmission Power(dBm)
Latitude Sign for Cell Center
Cell MIMO and DL64QAM Combined Capability Support Indicator
Horizontal Accuracy Code
Cell Radius(m)
Cell Radius Scene
Inter-RAT Measurement Configuration Index Related to Traffic Category
DUARFCN
Sector Identity
Cell F-DPCH Support Indicator
Number of Barred AC in CS Domain
URA Identity
Classified Zone Indicator
Prior Redirect RAT Indicator
Secondary SCH Power(dB)
Location Area Code
Altitude Accurary(m)
Service Area Code for CS and PS Domain
Degree of Polygon Point Latitude(degree)
Cell Dual Cell+MIMO Support Indicator
Cell MIMO Support Indicator
SCH TSTD Indicator
Preferred Traffic Type
Degrees of Polygon Point Longitude(degree)
Degrees of Antenna Longitude(degree)
PCCPCH STTD Indicator
Cell VAM Support Indicator
Service Area Code for BC Domain
Degrees of Longitude for Cell Center
P-CPICH Power(dBm)
Basic Priority AC Index
Mobility Configuration Scene
BCH Power(dB)
Antenna Latitude Sign
CS Domain Specific Access Class N Barred Indicator
PS Domain Specific Access Class N Barred Indicator
Switch of CS Domain DSAR
Direction of Antenna Altitude
MIMO Pilot Mode
Polygon Point Latitude Sign
Cell Enhanced F-DPCH Support Indicator
Pathloss Scenario
UL BLER Switch for Handover
Switch of Polling in PS Domain DSAR
AICH Power(dB)
Cell 64QAM Support Indicator
Switch of CS 64kbps Establishment
Common PLMN Indicator
P-CPICH Tx Diversity Indicator
Closed Loop Mode 1 Support Indicator
Load Balance Scene
Cell Type
Downlink Enhanced CELL_FACH Support Indicator
Cell Downlink Enhanced Layer 2 Support Indicator
Mobile Country Code
Scenario Type
PCH Power(dB)
Background Noise Automatic Adjustment Scene
HCS_PRIO
Multi-User Detection Support Indicator
Uplink Enhanced CELL_FACH Support Indicator
Switch of Polling in CS Domain DSAR
Scheduling Priority Index
NodeB Number
SACB Configuration Tag
Wait Time for RRC Connection Reestablishment(s)
Support MBMS Indicator
Polygon Point Number
Degree of Antenna Latitude
HSDPA Function Status
DL Tx Power Switch for Handover
STTD and MIMO Activation Binding Indicator
CMP Module Number
Cell Altitude for Cell Center(m)
Switch of Closing Frequency Intelligently Function
Intra-frequency Measurement Configuration Index Related to Traffic Category
Altitude Accurary Code
Offset Angle
Local Cell Identity
Antenna Altitude(m)
S-CPICH Support Indicator
HSUPA Function Status
Radio Capacity of Cell
Number of the Codes with SF =128 Ordered for OCNS
TUTRAN-GPS Measurement Support Indicator
UE Tx Power Switch for Handover
Switch of Paging and Location/Registration Restriction
Application Priority Index (Load Control)
Direction of Altitude for Cell Center
Inter-frequency Measurement Configuration Index Related to Traffic Category
Cell CPC Support Indicator
Switch of PS Domain DSAR
MIMO Indicator
Cell HSUPA 2ms TTI Support Indicator
UUARFCN
Confidence(%)
Frequency Band Indicator
MBMS Function Status
E-DCH User Number Level Used for HSUPA Adaptive Transmission
User Number with Compressed Mode Activation for Balance Strategy Based On Measurement
Power Offset for Downlink DPCH Initial Power Calculation when SRB Hard Handover
Vitrual Location Aera Code
MR-CELL Measurement Reporting Interval Coefficient
Maximum Number of Users on Downlink Enhanced CELL_FACH
MR-UE Measurement Switch
Power Offset for Downlink DPCH Initial Power Calculation when RAB Re-Establishment.
Power Offset for Downlink DPCH Initial Power Calculation when Soft or Softer Handover
Times of Downgrade of P-CPICH Power with Equal Step Used to Switch Off Frequency Intelligently
Absolute Priority Reselection Criteria Switch
Number of E-RGCH/E-HICH
Maximum Number of Users with Traffic on Common E-DCH in Enhancecd Uplink CELL_FACH State
Additional Time Period Before the UE Can Exit High-mobility in Case of HCS Usage (TCrMaxHyst)(s)
Increment to the Minimum Required Received Level in the Cell Configuration Tag
Sintrasearch Configuration Tag
Qqualmin-offset Present
Inter-RAT Scaling Factor for Treselection
Cell Reselection Timer Value for UE in CELL_FACH State (Treselections,FACH)(s)
Qrxlevmin-Offset Present
HCS Serving Cell Information Configuration Tag
Cell Reservation Extension
Cell Barred Indicator
Quality Threshold Level for Applying Prioritised Hierarchical Cell Reselection(QHcs) When
Measurement Quantity is CPICH RSCP(dBm)
Reselection Hysteresis 2 of Serving Cell (QHyst2s)(dB)
Switch of Deferred SIB11/11bis/12 Support
SsearchHCS Configuration Tag
Speed Dependent Scaling Factor for Treselection
Inter-frequency Scaling Factor for Treselection Configuration Tag
Reselection Hysteresis 2 of Serving Cell for UE in CELL_FACH State (Qhyst2s,FACH)(dB)
Qrxlevmin-offset(dB)
Measurement Quantity for Cell Selection and Reselection
Minimum Required Received Level in the Cell (Qrxlevmin)(dBm)
Cell Barred Time(Tbarred)(s)
Inter-RAT Scaling Factor for Treselection Configuration Tag
Duration for Evaluating Allowed Amount of Cell Reselection(s) in Case of Non-HCS Usage (Non-
HCS_TCRmax)(s)
Measurement Trigger Threshold for HCS Cell Reselection (SsearchHCS)(dB)
Increment to the Minimum Required Received Level in the Cell (DeltaQrxlevmin)(dB)
Reselection Hysteresis 1 of Serving Cell (QHyst1s)(dB)
Inter-System Measurement Trigger Threshold for HCS Cell Reselection (SHCS,RAT)(dB)
High HCS Priority Inter-system Cell Measurement Threshold for Cell Reselection (Slimit,SearchRAT)
(dB)
Quality Threshold Level for Applying Prioritised Hierarchical Cell Reselection (QHcs) When
Measurement Quantity is CPICH Ec/No(dB)
Speed Dependent Scaling Factor for Treselection Configuration Tag
Intra-frequency reporting quantity SIB3 when SIB11/11bis/12 deferred reading
Access Class N Barred Indicator (N=0..15)
Inter-frequency Scaling Factor for Treselection
Duration for Evaluating Allowed Amount of Cell Reselection(s) (TCRmax)(s)
CPICH EcN0 Measurement Trigger Threshold for Absolute Priority Reselection Criteria(dB)
HS-DPCCH ACK Power Offset for Single Radio Link or Intra-NodeB Handover
Power Offset for Scheduling Info (2ms TTI)
TPC Command Error Rate Target
CQI Repetition Factor
HS-DPCCH CQI Power Offset for Single Radio Link or Intra-NodeB Handover
Quantified E-DPCCH/DPCCH Power Offset (10ms TTI)
HS-DPCCH NACK Power Offset for Single Radio Link or Intra-NodeB Handover
ACK-NACK Repetition Factor
Power Offset for Scheduling Info (10ms TTI)
RNC Identity of Neighbouring Cell
Neighbouring Cell Identity
Does Neighbouring Cell Belong to Self Physical RNC
UE State Indicator Used for UTRAN Neighboring Cell Configuration
Use of HCS
Temporary_offset1 in SIB11(dB)
Penalty Time in SIB11(s)
Share Cover Indication
Cell Individual Offset(dB)
Temporary_offset2 in SIB12(dB)
Qhcs for CPICH RSCP in SIB11(dBm)
Temporary_offset1 in SIB12(dB)
Penalty Time in SIB12(s)
Quality Threshold Level (Qhcs) of Neighbouring Cell Broadcasted in SIB12(dB)
Quality Offset 1 (Qoffset1s,n) Between Serving Cell and Neighbouring Cell Broadcasted in
SIB11(dB)
Quality Offset 1 (Qoffset1s,n) Between Serving Cell and Neighbouring Cell Broadcasted in
SIB12(dB)
Qhcs for CPICH RSCP in SIB12(dBm)
Qhcs for CPICH Ec/No in SIB11(dB)
Qhcs for CPICH Ec/No in SIB12(dB)
Quality Threshold Level (Qhcs) of Neighbouring Cell Broadcasted in SIB11(dB)
Neighbouring GSM Cell Identifier
Location Area Code of Neighbouring GSM Cell
Use of HCS
5.0
0
10
1
0.0
1
1
0.0
0
0
5.0
0
0
0
3.0
0.0
0
2
0
3
0
8.0
0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0]
5
[8@64@128@384]
[3@6@9@11]
4
3
3
1.0@1.0@1.0@1.0@1.0@1.0@1.0@1.0@1.0@1.0@1.0@1.0@1.0@1.0]
2@12@12@12@24@24@24@24@24@24@96@96@96@96@96]
[5@10]
2@12@12@12@24@24@24@24@24@24@96@96@96@96@96]
[16@64@384]
3
8@8@8@8@16@16@16@16@16@16@64@64@64@64@64]
8@8@8@8@16@16@16@16@16@16@64@64@64@64@64]
[5@10]
0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0@0.0]
1
1
2
6
6
1.0
7
1
0
1
16
64
4
0
120
0
128
1
3
1
3
1
2
64
128
32
2
2
1
1
0
8
8
2
10
8
0
1
3
3
8
80
60
100
80
3
60
50
50
18
50
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
1
0
1
1
30
1
240
1
1
1
0
1
1
1
1
1
0
1
0
0
0
80
0
1
0
0
0
480
20
0
0
0
0
160
0
1
0
0
255
3
4
0
0
0
0
0
0
1
0
0
0
0
1
0
50
30
0
-13
6
0.0
0
5
1
0
5
3650
-108
200
1
0
[124@124@600]
1
[3@3@3]
3
70
30
0
0
0
30
2
14
3
44
0
0
500
5
1
7
0
6
600
30
0.0
1
0
10
0
2
1
50
0
2
0
0
0
0
0
2
100
0
150
0
0
0
0
65
0
8
0
1
7
1
1
Require More Info
0
0
1
0
0
0
0
0
6
0
18
80
300
1
1800
1
6
100
1
[0@1@2]
2
[6@6@6]
21
1
95
60
1
[3@3@3]
15
[21@21@45]
100
[6@6@6]
3
124
244
44
2
8
2
0
0
100
20
0
1
0
0
[512@0@955]
1
1
[885@124@1023]
65535
0
[10562@9662]
65535
2
1
0
3
0
[10838@9938]
0
15
0
2
1
1
0
1
0
0
0
0
0
1
0
0
0
2
0
64
4
10
1
30
64
0
0
1
0
0
0
1
1
0
2
5
0
4
10
2
0
[0]
0
[460]
[0.0]
100
0
1
100
600
300
20
5
0
Planning Parameter (0.0)
[2]
0
0
0.0
[0]
1
0
-5.0
0
0
300
1
64
0
200
5760
0
0
22:0:0
63
2
1
130
10
0
5
0
5
0
0
0
0
0
384
0
0
-108
384
3.0
0
21096000
3
0
0
0
0
0
0
0
0
0
0
1
14
1
20
1.0
10
1
0
10
0
20
2
0
0
2
50
6.0
2
60
-106.0
2
60.0
0
0
1
1
16
6.0
[65535@65535]
3
64
0
2.0
0
1
1
6
5760
4.0
50
7
0
7:0:0
-13
70
0.0
63
2
0.5
384
33
Optimization Parameter (0)
-7.0
384
0
2
5
0
384
5760000
0
0
1
64
16
40
15
700
0
3
0
Optimization Parameter
1
0
0
-17
0
1
8
2
16
0
2.0
2.0
0
0
1
2
-92
2
0
0
0.5
0
2
10
16
1
-115
0
0
9
-2
10
9
10
0
0
1
8
10
10
-12.0
0
0
65535
2.0
1
[10@10]
[-18]
[10@10]
Optimization Parameter
[14]
[1]
[14]
[20@20]
[14]
[-115]
[-128@-128]
0
[14@14]
[7@7]
[0@0]
[0]
[-18]
[0]
[-115]
[0]
0
[3@3]
6
[0]
[14]
10
[3400@1750]
10
1
1
0
95
5
0
95
1
55.0
70
1
0
98
85
0
5
5
0
1
0
0
57.0
100
0
61.0
62.0
3
1
96
1
1
1
0
3
1
1
-23
[15@15@15]
24
4095
[15@15@15]
-21.0
0
[0@0@0]
65
36
65535
[0.9]
6
1
[0@0@0@0@0@0@0]
1
5
2
0
4
3
5
0
4
9
10
11
3
2
12
1
6
6
Optimization Parameter
6
6
0.05
1
5
3
6
1
6
Planning Parameter
Planning Parameter
Planning Parameter
6
0
Planning Parameter
0
6
0
0
0
Planning Parameter
Not Used (0)
Not Used (0)
Not Used (1)
Not Used (-90)
Planning Parameter
[16]
1
Remark
Should we enable?
Should set to 2?
@0.0@0.0@0.0@0.0@0.0@0.0]
Should modify to 4?
@1.0@1.0@1.0@1.0@1.0@1.0]
24@96@96@96@96@96]
24@96@96@96@96@96]
Should modify to [16@64@128@384]?
@64@64@64@64@64]
@64@64@64@64@64]
@0.0@0.0@0.0@0.0@0.0@0.0]
Should enable?
Require to open for WB AMR trial
Require to open for HSUPA 5.76Mbps
Only valid when PSINTERSYSHOSUPP = 1
Should enable?
Should enable?
Should enable?
Not used
Should set to 1?
If require CDT, to open?
What is this?
Follow LAC ID
Follow Cell ID
Follow Cell ID
Refer to Handover Index sheet
Require parameter description
Require parameter description
Require parameter description
Require parameter description
Require parameter description
Require parameter description
Require parameter description
Require parameter description
Require parameter description
Require to optimize?
To be trial
Should explore?
Require to optimize?
2 - Only IRAT
3 - IFHO before IRAT
0 - use QQUALMIN (CelSel)
1 - use QQUALMINFDD (PriSel)
1 - 20 users
2 - 40 users
3 - 60 users
0 - Reserved
1 - Not Reserved
1 or 2
To re-visit OLC algorithm
1 - Not Used
2 - Used
Parameter valid only if USEOFHCS=2
Parameter valid only if USEOFHCS=2
Refer to Multicarrier Strategy
1 - Not Used
2 - Used
0 - Highest Priority
1 - Medium Priority
2 - Lowest Priority
PCH
64QAM Used
MIMO Used
DC Used
64QAM + DC Used
DC + MIMO Used
[0] - IUR
[6] - IUB
3G RAN Parameter Baseline V1.4 20131206
INTERNAL
Version Date
1.0 11-Oct-13
1.1 21-Oct-13
1.2 28-Oct-13
1.3 15-Nov-13
1.4 6-Dec-13
ameter Baseline V1.4 20131206
Description
First Version.
Tables included:
CelSel, CHspa, cnInfo, CUeTrv, drbc, ExtHspa, GloAc, Hspa, iuCnst, LdCtrl, nodeB,
Prach PriSel, QosSeg, rncBRnc, rncFunction, rncLocRnc, ueCnst, utranCell
Most baseline values filled in except several (highlighted red) that require further
study, revisit, or potential trials to identify best value.
Tables included:
CelMPO, EUtranCell, gsmRelation, Sccpch, UtranRelation
Tables included:
QosIndex
Included sheet for Handover Index (intra freq, inter freq, inter RAT).
Shamsul Azlie
Source: 3G Multicarrier Strategy_v4.0 (ZTE).pptx
Inter Frequency Measurements (CS & PS) TRFCATINTERMIDX
2013 Multi Carrier Strategy 200
Highway Improvement Project (HIP) - Step2 100
Highway Improvement Project (HIP) - Step1 110
Coverage Edge 300
Optimization - Set 1 400
Optimization - Set 2 410
Optimization - Set 3 420
Festive_Standby 600
Optimization 400 - 499
Trial/Testing Purpose 500 - 599
Festive/Special Event 600 - 699
E2F
RSCP E2D EcNo E2F EcNo
-101 -16 -13
-93 -10 -8
-93 -10 -8
-95 -16 -13
-95 -16 -13
-95 -16 -13
-95 -16 -13
-87 -12 -9
#N/A #N/A #N/A
#N/A #N/A #N/A
#N/A #N/A #N/A
E2F
RSCP E2D EcNo E2F EcNo
-109 -16 -13
-109 -16 -13
-109 -16 -13
-109 -16 -13
-109 -16 -13
-109 -16 -13
-109 -16 -13
-92 -12 -9
#N/A #N/A #N/A
#N/A #N/A #N/A
#N/A #N/A #N/A