Sie sind auf Seite 1von 2

Rain+Birdt Tech Spec

ESP-SMTe Controller Scheduling Features


Programming tutorial assures efficient and
ESP-SMTe Series Controllers accurate scheduling

Rain Birds powerful ET based controller now has Watering occurs only as needed and can be
a capacity of up to 22 zones and an enhanced restricted to selected days of the week, odd or
feature set that provides contractors with one even calendar days or at set intervals (cyclic)
of the most accurate ET based controllers in the Grow-in watering option allows a time based
industry. schedule for new plants for a programmed
period of time
The ESP-SMTe is available in outdoor and
Cycle+SoakTM feature for each zone prevents
indoor models, can be expanded in 3 or 6 zone
runoff based on soil type, precipitation rate
increments and is one of the only ET controllers
and landscape slope
on the market to measure site rainfall to ensure
accurate ET adjustments. Any zone can be switched to Time Based (for Electrical Specifications
example, to operate a pond pump)
Input required: 120 VAC 10%, 60Hz
Applications Copy Zone to Zone feature allows the
contractor to copy a zone program from one Output: 25.5 VAC 1A
The 22 zone capacity of the ESP-SMTe allows the
controller to meet the needs of both residential zone to another IP 24
and light-commercial irrigation systems. Advanced Features 3 zone valve capacity (two 24VAC, 7VA
Programming flexibility and onsite weather solenoids plus a master valve)
monitoring help meet even the strictest of Event Days Off allows you to select up to four
specific dates to block watering Nonvolatile memory saves programming
watering restrictions or local regulations.
Rainfall Shutdown suspends all irrigation 10 year life lithium battery maintains the
Easy to Use if the measured rainfall exceeds a user set controllers time and date
The ESP-SMTe Controller was designed threshold Master Valve/Pump Start Relay:
with ease of use in mind. The programming Cold Weather Shutdown suspends all Operating Voltage: 24VAC 50/60Hz
sequence walks the installer through the irrigation to prevent potential freeze damage Max Coil Inrush: 11VA
required information to accurately program the Contractor Default allows the controller Max Coil Holding: 5VA
controller. The controller allows zone features
zone settings to be saved/restored
to be copied to other zones with only a few Idle/Off power draw 0.06 amps at 120VAC
pushes of a button. Next Irrigation Estimate shows an estimated
schedule up to three weeks in advance Certifications
Easy to Install Weather Log holds historical weather data for WaterSense approved,
The ESP-SMTe Controller requires four mounting 30 days meets EPA criteria for
screws (included). A guide for or conduit high-performing, water
Event Log shows irrigation status for each efficient products
allows for professional installation of field wires zone for the past 30 days
into the cabinet. For larger field wire needs, UL, cUL, FCC Part 15b
remove the 1 diameter knockout opening. Manual Watering allows immediate watering
of a selected zone or all zones Dimensions
Now with Simple Smart Option Enable or disable Master Valve by zone Width: 10.7 in. (27,2 cm)
In Simple Smart mode the ESP-SMTe can be Advanced diagnostics and short circuit Height: 7.7 in. (19,5 cm)
programmed like a traditional time-based detection Depth: 4.4 in. (11,2 cm)
controller. Watering is scheduled on specific
days, with fixed start times and run times.
Operating Specifications
2 Watering Windows per zone How To Specify:
Controller Features Fine Tune watering adjustment -60% to +60%
EPA WaterSense labeled by zone ESP-SMTe Controller
Expandable to 22 zones Programmable delay between zones (default 120V 4-Zone Base Controller
English/Spanish Button easily switches the set to 3 seconds) ESP4SMTEI Indoor Model
display text between languages
ESP4SMTE Outdoor Model
Weather Sensor sends rainfall and
temperature data to the controller ESPSMTEUPG Upgrade kit for ESP-M and ESP-Me

Large LCD display with easy to use interface Expansion Modules


Non-Volatile (100- year) program memory ESPSM3 3-Zone Expansion Module
Remotely Programmable under 9V battery ESPSM6 6-Zone Expansion Module
power (not included)
* 6-Zone Module compatible with ESP-Me/
SMTe series controllers only. Not compatible
with prior models.
Rain+Birdt

Specifications The controller shall have a 12-hour AM/ The controller shall be EPA WaterSense
PM or 24 hour clock with a midnight day labeled.
The ESP-SMTe Controller shall be capable
change over. The controller shall have The controller shall offer manual watering
of fully automatic or manual operation.
a 365-day calendar backed up against of ALL zones sequentially or ONE zone at a
The controller shall be housed in a wall-
power interruptions by an internal lithium time. When manual watering is triggered,
mountable, weather resistant plastic cabinet
battery that will maintain date and time for the unit shall ignore data from the weather
with a key-locking cabinet door (outdoor
approximately 10 years. sensor (sensor pod) until manual watering is
models only). Only the outdoor model is
suitable for outdoor installation. The controller shall communicate with an completed.
onsite weather sensor that measures site The controller shall display on the screen
The controller shall include a base unit
temperature and rainfall. The controller the message NO AC to indicate to the user
module with 4 zones as well as three
shall contain a programmable rain shut off when AC Power is not present (if running on
expansion slots capable of receiving
threshold, which will suspend irrigation when batteries).
expansion modules of either three or six
a preset amount of rain is received.
zones to achieve total capacity of up to 22 The controller shall be compatible with
zones. The controller shall accept the modules The controller shall have an electronic Rain Birds LIMR (Landscape Irrigation
in any configuration and shall not require the diagnostic circuit breaker that shall sense Management Remote) and have a mechanism
installation of a three zone module in order to a zone with an electrical overload or to communicate with future expansion
install a six zone module. short circuit and shall bypass that zone accessories.
and continue to operate all other zones.
The controller shall be capable of operating The controller shall provide a method for the
When an electrical condition exists that is
two 24 VAC solenoid valves per zone plus a installer to save the irrigation schedule into
preventing normal operation the red LED
master valve or remote pump start relay. The non-volatile memory for easy recall later if
shall illuminate and remain illuminated and
controller shall operate on 120 VAC 10% at unwanted schedule changes are made.
display a message on the display as to what
60Hz.\
the problem is. The controller shall provide a method for the
The controller shall have two programming installer to restore the schedule to the factory
The controller shall offer a grow-in water
modes: fresh condition in order to start programming
feature, which allows the controller to run
a. Simple Smart Mode; Enabling a time based program for a user defined from a blank state.
programming like time-based controllers amount of time before converting to ET The controller shall provide a method to
with automatic adjustment of run times based programming. wire the controller through a , and 1
based on weather. wire conduit to allow for a more professional
A copy zone to zone feature shall be
b. Advanced ET Mode; Enabling adjustment built into the controller to allow for faster installation.
of both irrigation frequency and duration programming. The controller shall have a reset button to
based on onsite weather data. reset the controller in the case of micro-
The controller shall have a zone set up wizard
Watering day cycles shall be: No Restrictions, to assure all the necessary information is controller lock-up due to power surges or
By Day of the Week, Odd, Even and Cyclic accurately entered into the controller. frequent interruption of power to the power
(Every # day). No Restrictions, Odd, Even, and supply.
The controller shall allow fine tune watering
Cyclic shall support a Block Day of the Week. The controller shall be manufactured by Rain
from -60% to +60% by zone.
A day set to Block shall override the normal Bird Corporation in a NAFTA member country.
schedule. The controller shall allow the programmer to
set the estimated current moisture level of
The controller shall have an LCD display that
the soil at initial programming.
is capable of displaying each zones irrigation
scheduled start days and watering windows Logs, alarms, resets, irrigation events and
in the same screen with an active watering weather data shall be held for a 30 day period
notification that is displayed during irrigation. of time and be made easily accessible for
review.

Rain Bird Corporation Rain Bird Corporation Rain Bird International, Inc.
6991 East Southpoint Road 970 West Sierra Madre Ave. 1000 West Sierra Madre Ave.
Tucson, AZ 85756 Azusa, CA 91702 Azusa, CA 91702
Phone: (520) 741-6100 Phone: (626) 812-3400 Phone: (626) 963-9311
Fax: (520) 741-6522 Fax: (626) 812-3411 Fax: (626) 852-7343

Rain Bird Technical Services Specification Hotline The Intelligent Use of WaterTM


(800) RAINBIRD (1-800-724-6247) 1-800-458-3005 (U.S. and Canada) www.rainbird.com
(U.S. and Canada)

Registered Trademark of Rain Bird Corporation


2017 Rain Bird Corporation 13MA17 D40241EO