UCRETE MF-AS

Anti static, medium duty polyurethane concrete flooring system

DESCRIPTION (ASTM C597-83)


Tensile Strength (ISO R527) : 14000N/mm2
UCRETE MF-AS is a single layer, seamless, solvent-
Compressive Strength (BS6319: Part 2) : 51N/mm2
free, polyurethane flooring system with a smooth matt
surface finish. It has high impact resistance and Concrete Adhesion : concrete fails
withstands a wide spectrum of chemicals and abrasive (BS6319: Part 4)
wear. Coeff. Thermal Expansion : 5.8x 10-5 o C-
UCRETE MF-AS meets the antistatic flooring (ASTM C531) 1
specifications DIN 51953 and BS 2050 (explosive
Thermal Conductivity (BS874) : 1.1W/mo C
handling areas).
Surface Resistivity (BS2050) : 30 50 x 103
RECOMMENDED FOR (DIN 51953 1 m) : ohms
UCRETE MF-AS is recommended for conditions 40 80 x 103
requiring the maximum chemical resistance and where Density (BS6319:Part 5) ohms
3
thermal situations arise, from cool rooms to warm : 1880kg/m
environments.
Specific application include: PROPERTIES
electronics and component assembly
clean rooms Colours : Yellow ~ RAL 1004
pharmaceutical production Orange ~ RAL 2010
explosive and ammunition storage & handling Red ~ RAL 3001
textile and fibre production Green ~ RAL 6010
chemical plants Grey ~ RAL 7037
Thickness : 4 mm (minimum) to 6 mm
FEATURES AND BENEFITS Service temperatures
o o
at 6 mm : 60 C maximum & -20 C
Expert Installed only by trained and at 4 mm : 50oC maximum & -10oC
application approved specialist contractors.
APPLICATION
Fast Can be applied to 6-day-old
application/rapid concrete/2 day old polymer screed. Surface Preparation
access Short curing time and 8 hour access Concrete shall be clean, structurally sound and free from
to foot traffic; 20 hours for vehicles. foreign materials, contaminants, oily products and other
debris. Concrete surfaces shall be visibly dry with no
Hygienic/safe Slip resistant; non-tainting; non- standing water. The minimum tensile (pull-of) strength
dusting; monolithic (minimum joints); shall be 1.5N/mm2 and concrete shall have cured for at
easy to maintain; microbiologically least 5 days. Concrete substrates shall incorporate a
inert. continuous water proofing membrane.
Durable / long Wide chemical resistance; wear and Concrete design shall allow provisions for movement
life impact resistant; resists temperature joints, as required. In addition, provision shall be made
o o
from 20 C to 60 C at 6 mm for induced joints to allow shrinkage of the concrete to
thickness; 5 years of international occur along defined planes.
use.
Prepacked Preweighed/prepacked for All laitance shall be removed. All imperfections such as
immediate use; batch-to-batch holes and cracks shall be repaired and levelled with the
colour matched for consistency. mean level of the surface. For repairing surface
unevenness, EMACOconcrete repair system shall be
TYPICAL PERFORMANCE DATA used.
o The whole surface shall be enclosed and impact shot
(Test data 28 days @ 20 C) blasted, surface planed, ground or high-pressure water
Compressive Strength (BS6319:Part 2) : 51N/mm2 jetted. All high spots shall be removed. Surfaces shall be
Flexural Strength (ISO 178) : 20 N/mm2 rendered visibly dry by heat or mechanical means.
Dynamic E-Modulus 2
: 14000N/mm

Head Office Factories Representative Offices


Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
UCRETE MF-AS
Remove all loose material and dust by vacuum or SHELF LIFE
mechanical means.
UCRETE MF-AS can be kept for 9 months from date of
Priming manufacture when stored at 30oC or less above ground
UCRETE MF-AS shall be applied to cured scratch coat level and under cover in original unopened packaging,
of UCRETE MF-AS of 1mm nominal thickness. away from exposure to direct sunshine.

PRECAUTIONS
Placing
UCRETE MF-AS shall be mixed and applied only by Material Safety Data Sheets (MSDS) for each
specialist flooring contractors who have been trained in component of UCRETE MF-AS are available. Gloves
the correct application procedures. and eye protection shall be worn during mixing and
application.
CURING For detailed Health, Safety and Environmental
o
Recommendations, please consult and follow all
At 30 C, foot traffic access in 8 hours, vehicular traffic in instructions on the product Material Safety Data Sheets.
o
16 hours. At 20 C, foot traffic access in 12 hours,
vehicular traffic in 24 hours. Full cure at 28 days. OTHER INFORMATION
CLEANING Design and Preparation of substrates for UCRETE
Flooring
Regular cleaning, dry or wet mechanical scrubbing or BS8204 Part1: 1987 - Insitu Flooring code of practice
hot, flushing with detergents or detergent/sterilant for concrete bases and screed to receive insitu flooring
products will enhance the floors appearance and ICRI-Selection of surface preparation methods for
reduce soiling tendencies. concrete substrates receiving resin flooring.
BASF Construction Chemicals Product Data Sheets
ESTIMATING DATA for: EMACO concrete repair products.
2.30 to 2.50 kg/m2/mm thickness U MFAS/01/0800

PACKAGING
UCRETE MF-AS is supplied as a unit for immediate use,
consisting of:
UCRETE MF-AS Part 1 : 2.56kg
UCRETE MF-AS Part 2 : 2.73kg
UCRETE MF-AS Part 3 : 12.1kg
UCRETE MF-AS Carbon filter : 0.10kg

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.