Sie sind auf Seite 1von 2

CORRECTIVE AND PREVENTIVE ACTION 8D NO : CAPA 128

REPORT (8D REPORT) Date : 13.07.2015

Part No : WS4301D21 Supplier / In-house :

Part Name : 4" WS VALVE BODY ANSI UNC MALLIGA INDUSTRIES

Product : Valves
Source of complaint: Customer complaint / In-coming inspection
Repeated failure? No 8D-No: CAPA-128 Closed (Date): 13.07.15
Nature of Complaint: Sketch:

Qty Rejected : 5 Nos

Traceability part : NIL

D1 Problem Solving Team: QA & SCM Team

D2 Problem Description
.
5/8 UNC THREAD NO GO GAUGE ANSWERING

D3 Immediate containment action(s) (ICA): Resp.


Verified the stock & segregation done

D4 Root cause analysis: The supplier is black listed & no more supply will be done & parts will be scraped
For Occurrence

For Detection
D5 Possible permanent corrective action(s) (PCA) and verification: Resp. Target
For Occurrence- NA
.
For Detection -NA

D6 Verification of permanent corrective action(s) (PCA): NA Resp. Target

D7 Preventive actions to avoid recurrence: NA Resp. Target


Updation of Instruction sheet : NA
Updation of work instruction : NA
Updation of FMEA : NA
Updation of control plan : NA
Any other (one point lesson) : NA
D8 Congratulate your team: (acknowledgement, ideas for improvement). 8D closed
Meeting held (date)
WMI/MR/FM/12 REV 01

Das könnte Ihnen auch gefallen