Sie sind auf Seite 1von 6

LAMPIRAN TABEL PERHITUNGAN

Tabel 4.1. Data Design Gas Turbine Generator (GTG) PUSRI IB


Name Plated Data 2 Poles, 3 Phase, WYE Connected,
50Hz, 3000 rpm

Total temperature at rating gurantee 122 oC on armature by detector

not to exceed
133oC on filled by resistance

Maximum cold gas/ air temperature 400C

Kva (0 ft) 26650

Armature Amperes 115

Armature Volts 13800

Field Amperes 260

Exciter Volts 250

Power Factor 0,85

Voltage range at 50 Hz 5%

GTG load 23 MW, exhaust gas temp 4950C

GTG load 15 MW, exhaust gas temp 4470C

GTG load 7 MW, exhaust gas temp 3380C

GTG load 5,9 MW, exhaust gas temp 3270C


Tabel 4.2. Data Desain Waste Heat Boiler (WHB) PUSRI IB
Bagian Satuan

Capacity 90 Ton/jam

Exhaust Gas after turbine min 324 oC

Exhaust Gas after turbine max 500 oC

Exhaust Gas Flow 119,7 kg/detik

Neat Heat Value Gas 39,4 MJoule/NM3

Gas temperature at terminal point 28 oC

Gas pressure before at terminal point 28,12 bar G

Gas pressure before control valve max 3 bar G

Gas pressure before Burner 1 bar G

Gas quality at 1 bar 5600 NM3/jam

NOX content increase 10 ppm

CO content increase 20 ppm

Burner Type Duct Burner

No of Burner element 5

Burner Arrangement Flue gas duct

Temperature behind Burner 845 oC

O2 Content 14,5%
Tabel 4.3. Data Aktual, Data kuantitas sample dan GMS Pertamina di PUSRI IB

Parameter Hasil Satuan

CH4 74,95 %Mol

C2H6 6,77 %Mol

C3H8 5,36 %Mol

i-C4H10 0,82 %Mol

n-C4H10 1,08 %Mol

i-C5H12 0,32 %Mol

n-C5H12 0,22 %Mol

C6H14 0,18 %Mol

CO2 10,32 %Mol

H2S 4,98 ppm

N2 0 %Mol

Specific Gravity Calculation 0,6746 -

Nett Heating Value 9,405 Kcal/Nm3

Ar - -

H2 - -
Tabel 4.4. Data Aktual nilai BFW yang terdapat pada WHB PUSRI IB

Tanggal Boiler Feed Water

Flowrate Suhu

(Ton/Jam) (oC)

9 Juni 2016 59,25 113

10 Juni 2016 60,95 113

11 Juni 2016 60,92 113

12 Juni 2016 66,30 113

13 Juni 2016 68,43 113

14 Juni 2016 63,35 113

15 Juni 2016 63,18 113

Tabel 4.5. Data Aktual nilai Exhaust Gas yang terdapat pada WHB PUSRI IB

Tanggal Suhu Exhaust Gas (0C)

9 Juni 2016 476,42

10 Juni 2016 486,42

11 Juni 2016 482,17

12 Juni 2016 475,5

13 Juni 2016 483,5

14 Juni 2016 510,36

15 Juni 2016 474,75


Tabel 4.6. Data Aktual Nilai Temperatur yang terdapat padaWHB PUSRI IB

Suhu Suhu Suhu


Desuperheater Pembakaran Economizer
Tanggal
(oC) WHB (oC)
(oC)

9 Juni 2016 402,35 736,36 212,32

10 Juni 2016 401,50 736,46 212,33

11 Juni 2016 401,54 736,36 209,32

12 Juni 2016 403,63 786,55 207,01

13 Juni 2016 399,12 786,69 206,99

14 Juni 2016 403,74 776,63 206,83

15 Juni 2016 401,68 766,96 209,56

Tabel 4.7. Steam yang Dihasilkan di WHB PUSRI IB


Tanggal Steam WHB
(Ton/Jam)

9 Juni 2016 61,38

10 Juni 2016 61,43

11 Juni 2016 60,17

12 Juni 2016 67,83

13 Juni 2016
68,79

14 Juni 2016 66,55

15 Juni 2016 65,43

Das könnte Ihnen auch gefallen