Gas Temperature = 400 F Pressure = 1 atm Moisture Content = 5% v/v Dry Gas MW = 29 lb/mol Water MW = 18 lb/mol Particle mean size = 1 m Efficiency = 99.90% Gas constant, R = 0.7032 atm-ft3/(lb.mol.R)
Humidification of Inlet Gas
Hin = 0.03103448 lb water
lb dry gas
Hin =
From Psychrometric Chart
Tin = 400 F Tsat = 127 F Hsat = 0.1 lb water lb dry gas
Hsat =
Saturated Gas Flow rate
Qindry = 104,500.00 ACFM
dry = 0.07025561 lb dry gas/ft3 w = 0.04360693 lb water vapor/ft3 Qw = 11,611.11 ACFM Qinsat = 86,692.51 ACFM P = 47 in W.C
Throat Velocity (Used to size the scrubber)
(L/G) = 20 gallons/(1000 ACF)
K = 9.61769203 Bws = 0.16111111 moles water or ft3 water moles gas ft3 gas
sat = 0.06596222 lb-gas
ft3-gas
throat = 256.727374 ft.s-1
throat = 78.2505036 m.s-1 Dthroat = 2.67691219 ft = 81.5922834 cm