Sie sind auf Seite 1von 54

IM836-B

Ranger 305D May, 2007

For use with machines having Code Numbers: 11121, 11188, 11275

Safety Depends on You


Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.

OPERATORS MANUAL

Copyright 2007 Lincoln Global Inc.

World's Leader in Welding and Cutting Products


Sales and Service through Subsidiaries and Distributors Worldwide
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
i i
SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents The engine exhaust from this product contains
are known to the State of California to cause can- chemicals known to the State of California to cause
cer, birth defects, and other reproductive harm. cancer, birth defects, or other reproductive harm.
The Above For Diesel Engines The Above For Gasoline Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of Safety in Welding & Cutting - ANSI Standard Z49.1 from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of Arc Welding Safety booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE 1.h. To avoid scalding, do not remove the


radiator pressure cap when the engine is
powered equipment. hot.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated
areas or vent the engine exhaust fumes
outdoors.

ELECTRIC AND
MAGNETIC FIELDS
____________________________________________________
1.c. Do not add the fuel near an open flame may be dangerous
welding arc or when the engine is running.
Stop the engine and allow it to cool before 2.a. Electric current flowing through any conductor causes
refueling to prevent spilled fuel from vaporiz- localized Electric and Magnetic Fields (EMF). Welding
ing on contact with hot engine parts and current creates EMF fields around welding cables and
igniting. Do not spill fuel when filling tank. If welding machines
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated. 2.b. EMF fields may interfere with some pacemakers, and
____________________________________________________ welders having a pacemaker should consult their physician
1.d. Keep all equipment safety guards, covers and devices in before welding.
position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving 2.c. Exposure to EMF fields in welding may have other health
parts when starting, operating or repairing equipment. effects which are now not known.
____________________________________________________

1.e. In some cases it may be necessary to remove safety 2.d. All welders should use the following procedures in order to
guards to perform required maintenance. Remove minimize exposure to EMF fields from the welding circuit:
guards only when necessary and replace them when the
maintenance requiring their removal is complete. 2.d.1. Route the electrode and work cables together - Secure
Always use the greatest care when working near moving them with tape when possible.
parts.
___________________________________________________ 2.d.2. Never coil the electrode lead around your body.
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or 2.d.3. Do not place your body between the electrode and
idler by pushing on the throttle control rods work cables. If the electrode cable is on your right
while the engine is running. side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as


possible to the area being welded.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while 2.d.5. Do not work next to welding power source.
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate. Mar 95
ii ii
SAFETY
ELECTRIC SHOCK can ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
kill. plates to protect your eyes from sparks and
3.a. The electrode and work (or ground) circuits
the rays of the arc when welding or observing
are electrically hot when the welder is on. open arc welding. Headshield and filter lens
Do not touch these hot parts with your bare should conform to ANSI Z87. I standards.
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands. 4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
3.b. Insulate yourself from work and ground using dry insulation. the arc rays.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground. 4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
In addition to the normal safety precautions, if welding themselves to the arc rays or to hot spatter or metal.
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting, FUMES AND GASES
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use can be dangerous.
the following equipment: 5.a. Welding may produce fumes and gases
Semiautomatic DC Constant Voltage (Wire) Welder. hazardous to health. Avoid breathing these
DC Manual (Stick) Welder. fumes and gases.When welding, keep
AC Welder with Reduced Voltage Control. your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
3.c. In semiautomatic or automatic wire welding, the electrode, fumes and gases away from the breathing zone. When
electrode reel, welding head, nozzle or semiautomatic welding with electrodes which require special
welding gun are also electrically hot. ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
3.d. Always be sure the work cable makes a good electrical cadmium plated steel and other metals or coatings
connection with the metal being welded. The connection which produce highly toxic fumes, keep exposure as
should be as close as possible to the area being welded. low as possible and below Threshold Limit Values (TLV)
using local exhaust or mechanical ventilation. In
3.e. Ground the work or metal to be welded to a good electrical confined spaces or in some circumstances, outdoors, a
(earth) ground. respirator may be required. Additional precautions are
also required when welding on galvanized steel.
3.f. Maintain the electrode holder, work clamp, welding cable and
5. b. The operation of welding fume control equipment is affected
welding machine in good, safe operating condition. Replace
by various factors including proper use and positioning of
damaged insulation.
the equipment, maintenance of the equipment and the spe-
cific welding procedure and application involved. Worker
3.g. Never dip the electrode in water for cooling.
exposure level should be checked upon installation and
periodically thereafter to be certain it is within applicable
3.h. Never simultaneously touch electrically hot parts of
OSHA PEL and ACGIH TLV limits.
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
5.c. Do not weld in locations near chlorinated hydrocarbon vapors
of both welders.
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors to
3.i. When working above floor level, use a safety belt to protect
form phosgene, a highly toxic gas, and other irritating prod-
yourself from a fall should you get a shock.
ucts.
3.j. Also see Items 6.c. and 8.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.

5.e. Read and understand the manufacturers instructions for this


equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employers safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.

5.f. Also see item 1.b.

AUG 06
iii iii
SAFETY
WELDING and CUTTING CYLINDER may explode
SPARKS can if damaged.
cause fire or explosion. 7.a. Use only compressed gas cylinders
6.a. Remove fire hazards from the welding area. containing the correct shielding gas for the
If this is not possible, cover them to prevent process used and properly operating
the welding sparks from starting a fire. regulators designed for the gas and
Remember that welding sparks and hot pressure used. All hoses, fittings, etc. should be suitable for
materials from welding can easily go through small cracks the application and maintained in good condition.
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available. 7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous 7.c. Cylinders should be located:
situations. Refer to Safety in Welding and Cutting (ANSI Away from areas where they may be struck or subjected to
Standard Z49.1) and the operating information for the physical damage.
equipment being used.
A safe distance from arc welding or cutting operations and
6.c. When not welding, make certain no part of the electrode any other source of heat, sparks, or flame.
circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard. 7.d. Never allow the electrode, electrode holder or any other
electrically hot parts to touch a cylinder.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures 7.e. Keep your head and face away from the cylinder valve outlet
will not cause flammable or toxic vapors from substances when opening the cylinder valve.
inside. They can cause an explosion even though they have
been cleaned. For information, purchase Recommended 7.f. Valve protection caps should always be in place and hand
Safe Practices for the Preparation for Welding and Cutting of tight except when the cylinder is in use or connected for
Containers and Piping That Have Held Hazardous use.
Substances, AWS F4.1 from the American Welding Society
(see address above). 7.g. Read and follow the instructions on compressed gas
cylinders, associated equipment, and CGA publication P-l,
6.e. Vent hollow castings or containers before heating, cutting or Precautions for Safe Handling of Compressed Gases in
welding. They may explode. Cylinders, available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
6.f. Sparks and spatter are thrown from the welding arc. Wear oil
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
FOR ELECTRICALLY
Always wear safety glasses with side shields when in a powered equipment.
welding area.
8.a. Turn off input power using the disconnect
6.g. Connect the work cable to the work as close to the welding switch at the fuse box before working on
area as practical. Work cables connected to the building the equipment.
framework or other locations away from the welding area
increase the possibility of the welding current passing 8.b. Install equipment in accordance with the U.S. National
through lifting chains, crane cables or other alternate cir- Electrical Code, all local codes and the manufacturers
cuits. This can create fire hazards or overheat lifting chains recommendations.
or cables until they fail.
8.c. Ground the equipment in accordance with the U.S. National
6.h. Also see item 1.c. Electrical Code and the manufacturers recommendations.

6.I. Read and follow NFPA 51B Standard for Fire Prevention Jan 07
During Welding, Cutting and Other Hot Work, available
from NFPA, 1 Batterymarch Park,PO box 9101, Quincy, Ma
022690-9101.

6.j. Do not use a welding power source for pipe thawing.


iv iv
SAFETY
5. Toujours porter des lunettes de scurit dans la zone de
PRCAUTIONS DE SRET soudage. Utiliser des lunettes avec crans lateraux dans les
Pour votre propre protection lire et observer toutes les instruc- zones o lon pique le laitier.
tions et les prcautions de sret specifiques qui parraissent
dans ce manuel aussi bien que les prcautions de sret 6. Eloigner les matriaux inflammables ou les recouvrir afin de
gnrales suivantes: prvenir tout risque dincendie d aux tincelles.

Sret Pour Soudage A LArc 7. Quand on ne soude pas, poser la pince une endroit isol de
1. Protegez-vous contre la secousse lectrique: la masse. Un court-circuit accidental peut provoquer un
chauffement et un risque dincendie.
a. Les circuits llectrode et la pice sont sous tension
quand la machine souder est en marche. Eviter toujours 8. Sassurer que la masse est connecte le plus prs possible
tout contact entre les parties sous tension et la peau nue de la zone de travail quil est pratique de le faire. Si on place
ou les vtements mouills. Porter des gants secs et sans la masse sur la charpente de la construction ou dautres
trous pour isoler les mains. endroits loigns de la zone de travail, on augmente le risque
b. Faire trs attention de bien sisoler de la masse quand on de voir passer le courant de soudage par les chaines de lev-
soude dans des endroits humides, ou sur un plancher age, cbles de grue, ou autres circuits. Cela peut provoquer
metallique ou des grilles metalliques, principalement dans des risques dincendie ou dechauffement des chaines et des
les positions assis ou couch pour lesquelles une cbles jusqu ce quils se rompent.
grande partie du corps peut tre en contact avec la
masse. 9. Assurer une ventilation suffisante dans la zone de soudage.
c. Maintenir le porte-lectrode, la pince de masse, le cble Ceci est particulirement important pour le soudage de tles
de soudage et la machine souder en bon et sr tat galvanises plombes, ou cadmies ou tout autre mtal qui
defonctionnement. produit des fumes toxiques.
d.Ne jamais plonger le porte-lectrode dans leau pour le
refroidir. 10. Ne pas souder en prsence de vapeurs de chlore provenant
e. Ne jamais toucher simultanment les parties sous tension doprations de dgraissage, nettoyage ou pistolage. La
des porte-lectrodes connects deux machines soud- chaleur ou les rayons de larc peuvent ragir avec les
er parce que la tension entre les deux pinces peut tre le vapeurs du solvant pour produire du phosgne (gas forte-
total de la tension vide des deux machines. ment toxique) ou autres produits irritants.
f. Si on utilise la machine souder comme une source de
courant pour soudage semi-automatique, ces precautions 11. Pour obtenir de plus amples renseignements sur la sret,
pour le porte-lectrode sapplicuent aussi au pistolet de voir le code Code for safety in welding and cutting CSA
soudage. Standard W 117.2-1974.

2. Dans le cas de travail au dessus du niveau du sol, se pro-


tger contre les chutes dans le cas ou on recoit un choc. Ne
jamais enrouler le cble-lectrode autour de nimporte quelle
partie du corps.
PRCAUTIONS DE SRET POUR
LES MACHINES SOUDER
3. Un coup darc peut tre plus svre quun coup de soliel,
donc:
TRANSFORMATEUR ET
REDRESSEUR
a. Utiliser un bon masque avec un verre filtrant appropri
ainsi quun verre blanc afin de se protger les yeux du
rayonnement de larc et des projections quand on soude 1. Relier la terre le chassis du poste conformement au code
ou quand on regarde larc. de llectricit et aux recommendations du fabricant. Le dis-
b. Porter des vtements convenables afin de protger la positif de montage ou la piece souder doit tre branch
peau de soudeur et des aides contre le rayonnement de une bonne mise la terre.
larc.
c. Protger lautre personnel travaillant proximit au 2. Autant que possible, Iinstallation et lentretien du poste
soudage laide dcrans appropris et non-inflamma- seront effectus par un lectricien qualifi.
bles.
3. Avant de faires des travaux linterieur de poste, la
4. Des gouttes de laitier en fusion sont mises de larc de debrancher linterrupteur la boite de fusibles.
soudage. Se protger avec des vtements de protection
libres de lhuile, tels que les gants en cuir, chemise paisse, 4. Garder tous les couvercles et dispositifs de sret leur
pantalons sans revers, et chaussures montantes. place.

Mar. 93
v v

Thank You
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product
as much pride as we have in bringing this product to you!

CUSTOMER ASSISTANCE POLICY


The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip-
ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln
Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses-
sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor-
mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customers particular purpose,
with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any
warranty with respect to the sale of our products.

Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control
of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in
applying these types of fabrication methods and service requirements.

Subject to Change This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com
for any updated information.

Please Examine Carton and Equipment For Damage Immediately


When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.

Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.

Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above. The code number is especially important when identifying the correct replacement parts.

On-Line Product Registration


- Register your machine with Lincoln Electric either via fax or over the Internet.
For faxing: Complete the form on the back of the warranty statement included in the literature packet
accompanying this machine and fax the form per the instructions printed on it.
For On-Line Registration: Go to our WEB SITE at www.lincolnelectric.com. Choose Quick Links and then
Product Registration. Please complete the form and submit your registration.

Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:

WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.

CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
vi TABLE OF CONTENTS vi
Page

Installation.......................................................................................................................Section A
Technical Specifications .......................................................................................................A-1
Safety Precautions ........................................................................................................A-2
Location and Ventilation ................................................................................................A-2
Stacking ........................................................................................................................A-2
Angle of Operation ........................................................................................................A-2
Lifting.............................................................................................................................A-2
High Altitude Operation .................................................................................................A-2
High Temperature Operation ........................................................................................A-2
Cold Weather Operation ...............................................................................................A-2
Towing...........................................................................................................................A-3
Vehicle Mounting...........................................................................................................A-3
Pre-Operation Engine Service..............................................................................................A-3
Oil ..................................................................................................................................A-3
Fuel ...............................................................................................................................A-3
Engine Coolant..............................................................................................................A-4
Battery Connections ......................................................................................................A-4
Muffler Outlet Pipe ........................................................................................................A-4
Spark Arrester ...............................................................................................................A-4
Remote Control .............................................................................................................A-4
Electrical Connections ..........................................................................................................A-4
Machine Grounding .......................................................................................................A-4
Welding Terminals ........................................................................................................A-5
Welding Output Cables .................................................................................................A-5
Cable Installation...........................................................................................................A-5
Auxiliary Power Receptacles and Plugs ...............................................................................A-6
Standby Power Connections ................................................................................................A-6
Premises Wiring ...................................................................................................................A-7
Connection of Lincoln Electric Wire Feeders.................................................................A-8,A-9
________________________________________________________________________________

Operation.........................................................................................................................Section B
Safety Precautions ..............................................................................................................B-1
General Description..............................................................................................................B-1
For Auxiliary Power ..............................................................................................................B-1
Engine Operation..................................................................................................................B-1
Add Fuel ...............................................................................................................................B-1
Break in Period .....................................................................................................................B-1
Welder Controls .............................................................................................................B-2,B-3
Engine Controls ....................................................................................................................B-3
Starting and Stopping the Engine .................................................................................B-4
Welding Operation................................................................................................................B-4
Duty Cycle ..............................................................................................................B-4,B-5
Constant Current (Stick) Welding..................................................................................B-5
Downhill Pipe (Stick) Welding .......................................................................................B-5
Tig Welding ...................................................................................................................B-5
Typical Current Ranges for Tungsten Electrodes .........................................................B-5
Wire Welding-CV...........................................................................................................B-6
Arc Gouging ..................................................................................................................B-6
Auxiliary Power .............................................................................................................B-7
Simultaneous Welding and Auxiliary Power Loads .......................................................B-7
Extension Cord Recommendations...............................................................................B-7
________________________________________________________________________________

Accessories .....................................................................................................Section C
Field Installed Options / Accessories ...............................................................................C-1
________________________________________________________________________________
vii TABLE OF CONTENTS vii
Maintenance......................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine Maintenance ............................................................................................D-1
Engine Maintenance Components ........................................................................D-1
Kubota Diesel Engine ............................................................................................D-1
Engine Oil Change..........................................................................................D-2
Engine Oil Refill Capacities.............................................................................D-2
Engine Oil Filter Change.................................................................................D-2
Air Cleaner Service .........................................................................................D-2
Service Instructions And Installation Tips for Engine Air Filter .......................D-3
Cooling System .....................................................................................................D-4
Fan Belt...........................................................................................................D-4
Fuel .................................................................................................................D-4
Bleeding the Fuel System ...............................................................................D-4
Fuel Filter ........................................................................................................D-5
Engine Adjustment ..........................................................................................D-5
Battery Maintenance .......................................................................................D-5
Servicing Optional Spark Arrestor ...................................................................D-5
Welder / Generator Maintenance ........................................................................D-6
Storage ...........................................................................................................D-6
Cleaning..........................................................................................................D-6
Brush Removal and Replacement ..................................................................D-6
GFCI Testing and Resetting Procedure..........................................................D-6
________________________________________________________________________
Troubleshooting ..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide.............................................................................E-2 thru E-6
________________________________________________________________________
Diagrams and Dimension Print ......................................................................Section F
________________________________________________________________________
Parts List ..................................................................................................................P492
________________________________________________________________________
A-1 INSTALLATION A-1
TECHNICAL SPECIFICATIONS - Ranger 305D (K1727-2)
INPUT - DIESEL ENGINE
Make/Model Description Speed (RPM) Displacement Starting Capacities
cu. in. (cu. cm.) System

3 cylinder 43.88(789) 12VDC Battery & Fuel: 12 gal.


4 stroke starter (45 Liters)
18.8 HP High Idle 3650 Bore x Stroke inch (mm) Oil: 3.4Qts. (3.2L)
Kubota** (14 KW)
D722 Net intermittent Full Load 3500 2.64 x 2.68 (Group 58; 550 Radiator Coolant:
3600 RPM (67 x 68 mm) cold crank amps) 3.85Qts. (3.6L)
naturally aspirated Low Idle 2450 Battery Charger
water cooled (3.6L)
Diesel Engine
RATED OUTPUT @ 104 F (40 C) - WELDER
Welding Process Welding Output Output Range Max. Weld OCV
Current/Voltage/Duty Cycle @Rated Load RPM
DC Constant Current 305A / 29V / 100% 20 TO 305 AMPS
DC Pipe Current 300A / 29V / 100% 40 TO 300 AMPS
Touch-StartTIG 250A / 30V / 100% 20 TO 250 AMPS 60 Volts
DC Constant Voltage 300A / 29V / 100% 14 TO 29 VOLTS
RATED OUTPUT @ 104 F (40 C).- GENERATOR
Auxiliary Power 1
10,000 Watts Peak, / 9,500 Watts Continuous, 60 Hz 120/240 Volts
Sound Levels
Sound Power: 104.2 dB Lwa, Sound Level: 80.6 dBA @ 23 ft ( 7m )
PHYSICAL DIMENSIONS
HEIGHT WIDTH DEPTH WEIGHT
30.00* in. 21.50 in 52.25 in.
698 lbs. (317kg.)
762.0 mm 546.0 mm 1327.0 mm
ENGINE
LUBRICATION EMISSIONS FUEL SYSTEM GOVERNOR
Full Pressure Electric Fuel Pump (Code 11121) or Mechanical
with Full Flow Filter Certified to EPA Tier I Mechanical Fuel Pump (Code 11188, 11275), Auto air bleed Governor
system Electric shutoff solenoid Indirect fuel injector
AIR CLEANER ENGINE IDLER MUFFLER ENGINE PROTECTION
Low noise Muffler: Shutdown on low oil
Single Element Automatic Idler Top outlet can be rotated. pressure & engine
Made from long life, aluminized steel. temperature
ENGINE WARRANTY: 2 year complete (parts and labor) 3rd. year major components (parts and labor)
RECEPTACLES AND CIRCUIT BREAKERS
RECEPTACLES AUXILIARY POWER CIRCUIT BREAKER OTHER CIRCUIT BREAKERS

(2) 120VAC GFCI Duplex (5-20R) Two 20AMP for Two Duplex Receptacle 15AMP for Battery Charging Circuit
(1) 120/240VAC Dual Voltage One 50AMP for Dual Voltage(2-pole) 15AMP for 42V Wire Feeder Power
Full KVA (14-50R) Below code 11275 two 50AMP Below code 11275 Battery
cicuit breakers were used for Charging Circuit Breaker was
Dual Voltage 25 amps
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
* Top of enclosure add 6in. (152mm) for exhaust pipe.
** Engine warranty may vary outside of the USA. (See Engine warranty for details)

RANGER 305D
A-2 INSTALLATION A-2
SAFETY PRECAUTIONS LIFTING
The RANGER 305D weighs approximately
WARNING 775lbs.(352kg.) with a full tank of fuel (698 lbs. less
fuel). A lift bail is mounted to the machine and should
Do not attempt to use this equipment until you always be used when lifting the machine.
have thoroughly read the engine manufacturers
manual supplied with your welder. It includes WARNING
important safety precautions, detailed engine
Lift only with equipment of ade-
starting, operating and maintenance instructions,
and parts lists. quate lifting capacity.
------------------------------------------------------------------------ Be sure machine is stable when lift-
ELECTRIC SHOCK can kill. ing.
Do not touch electrically live parts or Do not lift this machine using lift
electrode with skin or wet clothing. bail if it is equipped with a heavy
Insulate yourself from work and accessory such as trailer or gas
ground cylinder.
Always wear dry insulating gloves.
------------------------------------------------------------------------ FALLING Do not lift machine if lift bail is
ENGINE EXHAUST can kill. EQUIPMENT can damaged.
Use in open, well ventilated areas or cause injury. Do not operate machine while
vent exhaust outside.
suspended from lift bail.
------------------------------------------------------------------------ --------------------------------------------------------------------------------
MOVING PARTS can injure.
Do not operate with doors open or HIGH ALTITUDE OPERATION
guards off. At higher altitudes, output derating may be necessary. For max-
Stop engine before servicing. imum rating, derate the machine 2.5% to 3.5% for every 1000 ft.
Keep away from moving parts.
------------------------------------------------------------------------ (305m). Due to new EPA and other local emissions regulations,
See additional warning information at modifications to the engine for high altitude are restricted within
the United States and some other European Countries. Use
front of this operators manual.
above 6000 ft.(1828 m) may be limited due to poor engine per-
Only qualified personnel should install, formance or excessive exhaust smoke. An authorized Kubota
use, or service this equipment. engine field service shop should be contacted to determine if
any adjustments can be made for operation in higher elevations
LOCATION AND VENTILATION locally.

The welder should be located to provide an unrestrict- HIGH TEMPERATURE OPERATION


ed flow of clean, cool air to the cooling air inlets and to At temperatures above 104F(40C), Welder output derating is
avoid restricting the cooling air outlets. Also, locate the necessary. For maximum output ratings, derate the welder out-
welder so that the engine exhaust fumes are properly put 2 volts for every 50F(10C) above 104F(40C).
vented to an outside area.

STACKING Cold weather starting:


With a fully charged battery and the proper weight oil,
RANGER 305D machines cannot be stacked. the engine should start satisfactorily even down to
about 5F (-15C). If the engine must be frequently
ANGLE OF OPERATION started at or below 23F (-5C), it may be desirable to
Engines are designed to run in the level condition install cold-starting aides. The use of No. 1D diesel
which is where the optimum performance is achieved. fuel is recommended in place of No. 2D at tempera-
The maximum angle of continuous operation is 20 tures below 23F (-5C). Allow the engine to warm up
degrees in all directions, 35 degrees Intermittent (less before applying a load or switching to high idle.
than 10 minutes continuous) in all directions. If the Note: Extreme cold weather starting may require
engine is to be operated at an angle, provisions must longer glow plug operation.
be made for checking and maintaining the oil level at
the normal (FULL) oil capacity in the crankcase. WARNING
When operating the welder at an angle, the effective Under no conditions should ether or other starting
fuel capacity will be slightly less than the specified 12 fluids be used with this engine!
gallons (45ltrs.). ------------------------------------------------------------------------

RANGER 305D
A-3 INSTALLATION A-3

TOWING PRE-OPERATION ENGINE SERVICE


The recommended trailer for use with this equipment for road, READ the engine operating and maintenance instruc-
in-plant and yard towing by a vehicle(1) is Lincolns K957-1. If tions supplied with this machine.
the user adapts a non-Lincoln trailer, he must assume responsi-
bility that the method of attachment and usage does not result WARNING
in a safety hazard nor damage the welding equipment. Some of
the factors to be considered are as follows: Stop engine and allow to cool before fueling
Do not smoke when fueling.
1. Design capacity of trailer vs. weight of Lincoln equipment and Fill fuel tank at a moderate rate and do not over-
likely additional attachments. fill.
Wipe up spilled fuel and allow fumes to clear
2. Proper support of, and attachment to, the base of the weld- before starting engine.
ing equipment so there will be no undue stress to the frame- Keep sparks and flame away from tank.
work. ------------------------------------------------------------------------
OIL
3. Proper placement of the equipment on the trailer to insure The RANGER 305D is shipped with the engine
stability side to side and front to back when being moved crankcase filled with high quality SAE 10W-30 Oil that
and when standing by itself while being operated or ser- meets classification CG-4 or CH-4 for diesel engines.
viced. Check the oil level before starting the engine. If it is
not up to the full mark on the dip stick, add oil as
4. Typical conditions of use, i.e., travel speed; roughness of sur- required. Check the oil level every four hours of run-
face on which the trailer will be operated; environmental con- ning time during the first 50 running hours. Refer to
ditions; like maintenance. the engine Operators Manual for specific oil recom-
mendations and break-in information. The oil change
5. Conformance with federal, state and local laws.(1) interval is dependent on the quality of the oil and the
(1) Consult applicable federal, state and local laws regarding specific requirements for use on public high- operating environment. Refer to the Engine Operators
ways. Manual for more details on the proper service and
VEHICLE MOUNTING maintenance intervals.

WARNING FUEL
USE DIESEL FUEL ONLY
Improperly mounted concentrated loads may
cause unstable vehicle handling and tires or other WARNING
components to fail.
Fill the fuel tank with clean, fresh fuel. The
Only transport this Equipment on serviceable capacity of the tank is 12 gals. (45.4ltrs). When
vehicles which are rated and designed for such the fuel gauge reads empty the tank contains
loads. approximately 2 gals. (7.6ltrs.) of reserve fuel.
Distribute, balance and secure loads so vehicle
is stable under conditions of use. WARNING
Do not exceed maximum rated loads for compo-
nents such as suspension, axles and tires. NOTE: A fuel shut off valve is located on the pre-
Mount equipment base to metal bed or frame of filter/sediment filter. Which should be in
vehicle. the closed position when the welder is not
Follow vehicle manufacturers instructions. ran for extended periods of time.
------------------------------------------------------------------------ ------------------------------------------------------------------------

RANGER 305D
A-4 INSTALLATION A-4

ENGINE COOLING SYSTEM REMOTE CONTROL


The RANGER 305D is equipped with a 6-pin and a
14-pin connector. The 6-pin connector is for connect-
WARNING ing the K857 or K857-1 Remote Control or for TIG
Air to cool the engine is drawn in the base sides welding, the K870 foot Amptrol or the K936-3 hand
and exhaust through radiator & case back. It is Amptrol. When in the CC-STICK, DOWNHILL PIPE,
important that the intake and exhaust air is not or CV-WIRE modes and when a remote control is
restricted. Allow a minimum clearance of 2 feet connected to the 6-pin Connector, the auto-sensing
(0.6m) from the case back and 16in.(406mm) from circuit automatically switches the OUTPUT control
either side of the base to a vertical surface. from control at the welder to remote control.
------------------------------------------------------------------------
When in TOUCH START TIG mode and when a
BATTERY CONNECTION Amptrol is connected to the 6-Pin Connector, the
OUTPUT dial is used to set the maximum current
CAUTION range of the CURRENT CONTROL of the Amptrol.

Use caution as the electrolyte is a strong acid that The 14-pin connector is used to directly connect a
can burn skin and damage eyes. wire feeder control cable. In the CV-WIRE mode,
------------------------------------------------------------------------ when the control cable is connected to the 14-pin con-
nector, the auto-sensing circuit automatically makes
The RANGER 305D is shipped with the negative bat- the Output Control inactive and the wire feeder volt-
tery cable disconnected. Make certain that the RUN- age control active
STOP switch is in the STOP position. Remove the two
screws from the rear battery tray using a screwdriver WARNING
or a 3/8" socket. Attach the negative battery cable to
the negative battery terminal and tighten using a 1/2"
NOTE: When a wire feeder with a built in welding
socket or wrench.
voltage control is connected to the 14-pin connec-
tor, do not connect anything to the 6-pin connec-
NOTE: This machine is furnished with a wet charged
tor.
battery; if unused for several months, the battery may
require a booster charge. Be careful to charge the bat- ------------------------------------------------------------------------
tery with the correct polarity. ELECTRICAL CONNECTIONS
MUFFLER OUTLET PIPE
Using the clamp provided secure the outlet pipe to the MACHINE GROUNDING
outlet tube with the pipe positioned such that it will Because this portable engine driven welder creates its
direct the exhaust in the desired direction. Tighten own power, it is not necessary to connect its frame to
using a 9/16" socket or wrench. an earth ground, unless the machine is connected to
premises wiring (home, shop, etc.)
SPARK ARRESTER
Some federal, state or local laws may require that
To prevent dangerous electric shock, other equipment
gasoline or diesel engines be equipped with exhaust
to which this engine driven welder supplies power
spark arresters when they are operated in certain
must:
locations where unarrested sparks may present a fire
hazard. The standard muffler included with this welder
does not qualify as a spark arrester. When required by WARNING
local regulations, a suitable spark arrester, such as
Be grounded to the frame of the welder using a
the K1898-1 must be installed and properly main-
grounded type plug.
tained.
Be double insulated.
WARNING Do not ground the machine to a pipe that carries
explosive or combustible material.
An incorrect spark arrestor may lead to damage to
------------------------------------------------------------------------
the engine or adversely affect performance.
------------------------------------------------------------------------

RANGER 305D
A-5 INSTALLATION A-5
When this welder is mounted on a truck or trailer, its CABLE INSTALLATION
frame must be electrically bonded to the metal frame Install the welding cables to your RANGER 305D as
of the vehicle. Use a #8 or larger copper wire connect- follows.
ed between the machine grounding stud and the
frame of the vehicle. When this engine driven welder 1. The engine must be OFF to install welding cables.
is connected to premises wiring such as that in a
home or shop, its frame must be connected to the sys- 2. Remove the flanged nuts from the output terminals
tem earth ground. See further connection instructions .
in the section entitled "Standby Power Connections" 3. Connect the electrode holder and work cables to the
as well as the article on grounding in the latest weld output terminals. The terminals are identified
National Electrical Code and the local code. on the case front.

In general, if the machine is to be grounded, it should 4. Tighten the flanged nuts securely.
be connected with a #8 or larger copper wire to a solid
earth ground such as a metal water pipe going into the 5. Be certain that the metal piece you are welding (the
ground for at least ten feet and having no insulated work) is properly connected to the work clamp and
joints, or to the metal framework of a building which cable.
has been effectively grounded.
6. Check and tighten the connections periodically.
The National Electrical Code lists a number of alter-
nate means of grounding electrical equipment. A CAUTION
machine grounding stud marked with the symbol
is provided on the front of the welder. Loose connections will cause the output termi-
nals to overheat. The terminals may eventually
WELDING TERMINALS melt.
The RANGER 305D is equipped with a toggle switch Do not cross the welding cables at the output ter-
for selecting "hot" welding terminal when in the "WELD minal connection. Keep the cables isolated and
TERMINALS ON" position or "cold" welding terminal separate from one another.
when in the "REMOTELY CONTROLLED" position. ------------------------------------------------------------------------

WELDING OUTPUT CABLES


With the engine off connect the electrode and work
cables to the output studs. The welding process dic-
tates the polarity of the electrode cable. These con-
nections should be checked periodically and tightened
with a 3/4" wrench.

Table A.1 lists recommended cable sizes and lengths


for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.

TABLE A.1

TOTAL COMBINED LENGTH OF


ELECTRODE AND WORK CABLES
Cable Size for
Cable Length 305 Amps
100% Duty Cycle
0-100Ft. (0-30 meters) 1 / 0 AWG

100-150 Ft. (30-46 meters) 2 / 0 AWG

150-200 Ft. (46-61 meters) 3 / 0 AWG

RANGER 305D
A-6 INSTALLATION A-6
AUXILIARY POWER RECEPTACLES Install the double-pole, double-throw switch
between the power company meter and the premis-
Start the engine and set the IDLER control switch to es disconnect. Switch rating must be the same or
the High Idle mode. Voltage is now correct at the greater than the customers premises disconnect
receptacles for auxiliary power. This must be done and service over current protection.
before a tripped GFCI receptacle can be reset prop-
erly. See the MAINTENANCE section for detailed Take necessary steps to assure load is limited to
information on testing and resetting the GFCI recep- the capacity of the RANGER 305D by installing a 50
tacle. amp, 240 VAC double pole circuit breaker.
Maximum rated load for each leg of the 240 VAC
The auxiliary power of the RANGER 305D consists of auxiliary is 40 amperes. Loading above the rated
two 20 Amp-120 VAC (5-20R) duplex receptacles output will reduce output voltage below the allow-
with GFCI protection and one 50 Amp 120/240 VAC able - 10% of rated voltage which may damage
(14-50R) receptacle. The 240 VAC receptacle can be appliances or other motor-driven equipment and
split for single phase 120 VAC operation. may result in overheating of the RANGER 305D
engine and/or alternator windings.
The auxiliary power capacity is 10,000 watts Peak,
9,500 Watts Continuous of 60 Hz, single phase Install a 50 amp, 120/240 VAC plug (NEMA Type
power. The auxiliary power capacity rating in watts is 14-50) to the double-pole circuit breaker using No.
equivalent to volt-amperes at unity power factor. The 6, 4 conductor cable of the desired length. (The 50
max permissible current of the 240 VAC output is 40 amp, 120/240 VAC plug is available in the optional
amps. The 240 VAC output can be split to provide K802R plug kit or as part number T12153-9.)
two separate 120 VAC outputs with a max permissi-
ble current of 40 Amps per output to two separate Plug this cable into the 50 Amp, 120/240 Volt recep-
120 VAC branch circuits (these circuits cannot be tacle on the RANGER 305D case front.
paralleled). Output voltage is within 10% at all loads
up to rated capacity. All auxiliary power is protected
by circuit breakers.

The 120 V auxiliary power receptacles should only be


used with three wire grounded type plugs or
approved double insulated tools with two wire plugs.
The current rating of any plug used with the system
must be at least equal to the current capacity of the
associated receptacle.

NOTE: The 240 V receptacle has two 120 V circuits,


but are of opposite polarities and cannot be paral-
leled.

STANDBY POWER CONNECTIONS

The RANGER 305D is suitable for temporary, stand-


by or emergency power using the engine manufactur-
ers recommended maintenance schedule.

The RANGER 305D can be permanently installed as


a standby power unit for 240 VAC, 3 wire, single
phase, 40 amp service. Connections must be made
by a licensed electrician who can determine how the
120/240 VAC power can be adapted to the particular
installation and comply with all applicable electrical
codes.

RANGER 305D
A-7 INSTALLATION A-7

CONNECTION OF RANGER 305D TO PREMISES WIRING

240 VOLT

GROUNDED CONDUCTOR
240 Volt POWER
120 VOLT
60 Hz.
3-Wire COMPANY
120 VOLT
Service
METER

NEUTRAL
BUS
N
LOAD

DOUBLE POLE DOUBLE THROW


SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.

PREMISES
DISCONNECT AND
SERVICE
GROUND OVERCURRENT
50AMP
240 VOLT PROTECTION

DOUBLE
POLE
50 AMP, 120/240 CIRCUIT
VOLT PLUG 240 VOLT BREAKER
NEMA TYPE 14-50

GND

50 AMP, 120/240 VOLT


RECEPTACLE NOTE: No. 6 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
SIZE RECOMMENDATIONS.

WARNING
Only a licensed, certified, trained electrician should install the machine to a premises or residential
electrical system. Be certain that:

The installation complies with the National Electrical Code and all other applicable electrical codes.

The premises is isolated and no feedback into the utility system can occur. Certain state and local
laws require the premises to be isolated before the generator is linked to the premises. Check your
state and local requirements.

A double pole, double throw transfer switch in conjunction with the properly rated double throw
circuit breaker is connected between the generator power and the utility meter.

RANGER 305D
A-8 INSTALLATION A-8
Across The-Arc Model:
CONNECTION OF LINCOLN ELECTRIC
WIRE FEEDERS Attach the single lead from the front of the LN-15 to
work using the spring clip at the end of the lead. This
Connection of LN-7 or LN-8 to the RANGER 305D is a control lead to supply current to the wire feeder
motor; it does not carry welding current.
Shut the welder off.
Set the "WELD TERMINALS" switch to "WELD TER-
Connect the LN-7 or LN-8 per instructions on the MINALS ON"
appropriate connection diagram in Section F.
Control Cable Model:
Set the "WIRE FEEDER VOLTMETER" switch to
either "+" or "-" as required by the electrode being Connect Control Cable between Engine Welder and
used. Feeder.

Set the "MODE" switch to the "CV WIRE " position. Set the "WELD TERMINALS" switch to "REMOTELY
Set the "ARC CONTROL" knob to "0" initially and CONTROLLED".
adjust to suit.
Set the MODE switch to the "CV-WIRE " position.
Set the "WELD TERMINALS" switch to the
"REMOTELY CONTROLLED" position. Set the "WIRE FEEDER VOLTMETER" switch to
either "+" or "-" as required by the electrode polarity
Set the "IDLE" switch to the "HIGH" position. being used.

Connection of LN-15 to the Ranger 305D Set the "ARC CONTROL" knob to "0" initially and
adjust to suit.
These connections instructions apply to both the LN-
15 Across The-Arc and Control Cable models. The Set the "IDLE" switch to the "AUTO" position
LN-15 has an internal contactor and the electrode is
not energized until the gun trigger is closed. When the
gun trigger is closed the wire will begin to feed and the
welding process is started.

Shut the welder off.

For electrode Positive, connect the electrode cable


to the "+" terminal of the welder and work cable to
the "-" terminal of the welder. For electrode
Negative, connect the electrode cable "-" terminal of
the welder and work cable to the "+" terminal of the
welder.

RANGER 305D
A-9 INSTALLATION A-9
Connection of the LN-25 to the RANGER 305D Connection of LN-742, Spool Gun (K487-25) and
Cobramatic to RANGER 305D
WARNING
Shut the welder off.
Shut off welder before making any electrical con-
nections. Connect per instructions on the appropriate connec-
------------------------------------------------------------------------ tion diagram in Section F.
The LN-25 with or without an internal contactor may
be used with the RANGER 305D. See the appropriate Connection of PRINCE XL SPOOL GUN to the
connection diagram in Section F. Ranger 305D

NOTE: The LN-25 (K431) Remote Control Module Connection of the Prince XL Spool Gun requires the
and (K432) Remote Cable are not recommended for use of the K1849-1 Adapter Module.
use with the RANGER 305D.
Shut the Welder off.
1. Shut the welder off.
For electrode Positive, connect the electrode cable
2. For electrode Positive, connect the electrode to the "+" terminal of the welder and work cable to
cable from the LN-25 to the "+" terminal of the the "-" terminal of the welder. For electrode
welder and work cable to the "-" terminal of the Negative, connect the electrode cable "-" terminal of
welder. For electrode Negative, connect the elec- the welder and work cable to the "+" terminal of the
trode cable from the LN-25 to the "-" terminal of welder.
the welder and work cable to the "+" terminal of
the welder. Connect the Control Cable of the Spool Gun to the
Adapter Module and connect the Control Cable of
3. Attach the single lead from the front of the LN-25 the Adapter Module to the Welder.
to work using the spring clip at the end of the lead.
This is a control lead to supply current to the wire Connect the Gas Hose.
feeder motor; it does not carry welding current.
Set the MODE switch to the "CV-WIRE " position.
4. Set the MODE switch to the "CV-WIRE " position.
Set the "WELD TERMINALS" switch to "WELD
5. Set the "WELD TERMINALS" switch to "WELD TERMINALS ON".
TERMINALS ON"
Set the "ARC CONTROL" knob to "0" initially and
6. Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
adjust to suit.
Set the IDLE switch to the HIGH position.
7. Set the "IDLE" switch to the "AUTO" position.
When not welding, the RANGER 305D engine will
be at the low idle speed. If you are using an LN-25
with an internal contactor, the electrode is not
energized until the gun trigger is closed.

8. When the gun trigger is closed, the current sens-


ing circuit will cause the RANGER 305D engine to
go to the high idle speed, the wire will begin to
feed and the welding process started. When weld-
ing is stopped, the engine will revert to low idle
speed after approximately 12 seconds unless
welding is resumed.

CAUTION
If you are using an LN-25 without an internal con-
tactor, the electrode will be energized when the
Ranger 305D is started.
------------------------------------------------------------------------
RANGER 305D
B-1 OPERATION B-1
SAFETY PRECAUTIONS Add oil (if necessary) to bring the level up to the full
mark. Do not overfill. Close engine door.
Check radiator for proper coolant level. (Fill if nec-
WARNING essary).
See Engine Owners Manual for specific oil and
Do not attempt to use this equipment until you coolant recommendations.
have thoroughly read the engine manufacturers
manual supplied with your welder. It includes ADD FUEL
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists. WARNING
------------------------------------------------------------------------
ELECTRIC SHOCK can kill. Stop engine while fueling.
Do not touch electrically live parts or Do not smoke when fueling.
electrode with skin or wet clothing.
Insulate yourself from work and Keep sparks and flame away
ground from tank.
Always wear dry insulating gloves. Do not leave unattended while
fueling.
Always operate the welder with the hinged door
Wipe up spilled fuel and allow
closed and the side panels in place. DIESEL FUEL
can cause fire. fumes to clear before starting
Read carefully the Safety Precautions page
before operating this machine. Always follow engine.
these and any other safety procedures included Do not overfill tank, fuel
in this manual and in the Engine Instruction expansion may cause over-
Manual. flow.
DIESEL FUEL ONLY
GENERAL DESCRIPTION ------------------------------------------------------------------------
Remove the fuel tank cap.
The RANGER 305D is a diesel engine powered DC
Fill the tank approximately 4 inches (100mm) from
multi-process welding power source and 120 / 240
the top of the filler neck to allow for fuel expansion .
volt AC power generator. The engine drives a genera-
DO NOT FILL THE TANK TO THE POINT OF
tor that supplies three phase power for the DC weld-
OVERFLOW.
ing circuit and single phase power for the AC auxiliary
outlets. The DC welding control system uses state of
Replace the fuel cap and tighten securely.
the art Chopper Technology (CT tm) for superior weld-
ing performance.
See Engine Owners Manual for specific fuel recom-
mendations.
FOR AUXILIARY POWER:
Start the engine and set the IDLER control switch to BREAK-IN PERIOD
the desired operating mode. Full power is available
regardless of the welding control settings providing no Any engine will use a small amount of oil during its
welding current is being drawn. break-in period. For the diesel engine on the
RANGER 305D, break-in is about 50 running hours.
The auxiliary power of the RANGER 305D consists of
two 20 Amp-120 VAC (5-20R) duplex receptacles with Check the oil every four hours during break-in.
GFCI protection and one 50 Amp 120/240 VAC (14- Change the oil after the first 50 hours of
50R) receptacle. The 240 VAC receptacle can be split operation,every 100 hours thereafter. Change the oil
for single phase 120 VAC operation. Also refer to the filter at the second oil change.
AUXILIARY POWER OPERATION section later in this
chapter.
CAUTION
ENGINE OPERATION During break-in, subject the RANGER 305D to
Before Starting the Engine: moderate loads. Avoid long periods running at
Be sure the machine is on a level surface. idle. Before stopping the engine, remove all loads
Open top & side engine doors and remove the and allow the engine to cool several minutes.
engine oil dipstick and wipe it with a clean cloth. ------------------------------------------------------------------------
Reinsert the dipstick and check the level on the dip-
stick.
RANGER 305D
B-2 OPERATION B-2

16
1
15

14
2 17

13
3
12

11

4
10

5 7

FIGURE B.1 6
WELDING CONTROLS (Figure B.1) 2. DIGITAL OUTPUT METERS- The digital
meters allow the output voltage (CV-WIRE mode)
1. OUTPUT CONTROL- The OUTPUT dial is or current (CC-STICK,DOWN HILL PIPE and TIG
used to preset the output voltage or current as dis- modes) to be set prior to welding using the OUT-
played on the digital meters for the four welding PUT control dial. During welding, the meter dis-
modes. When in the CC-STICK, DOWNHILL PIPE play the actual output voltage (VOLTS) and cur-
or CV-WIRE modes and when a remote control is rent (AMPS). A memory feature holds the display
connected to the 6-Pin or 14-Pin Connector, the of both meters on for seven seconds after welding
auto-sensing circuit automatically switches the is stopped. This allows the operator to read the
OUTPUT CONTROL from control at the welder to actual current and voltage just prior to when weld-
the remote control. ing was ceased.

In the CV-WIRE mode, when the wire feeder con- While the display is being held the left-most deci-
trol cable is connected to the 14-Pin Connector, the mal point in each display will be flashing. The
auto-sensing circuit automatically makes OUTPUT accuracy of the meters is +/- 3%.
CONTROL inactive and the wire feeder voltage
control active. 3. WELD MODE SELECTOR SWITCH-
(Provides four selectable welding modes)
CV-WIRE
When in the TOUCH START TIG mode and when a
DOWNHILL PIPE
Amptrol is connected to the 6-Pin Connector, the
CC-STICK
OUTPUT dial is used to set the maximum current
TOUCH START TIG
range of the CURRENT CONTROL of the Amptrol.

RANGER 305D
B-3 OPERATION B-3

4. ARC CONTROL- The ARC CONTROL dial is active in 10. WIRE FEEDER VOLTMETER SWITCH:
Matches the polarity of the wire feeder voltmeter to
the CV-WIRE, CC-STICK and DOWNHILL PIPE modes,
the polarity of the electrode.
and has different functions in these modes. This control is
not active in the TIG mode.
ENGINE CONTROLS: (Figure B.2)
CC-STICK mode: In this mode, the ARC CONTROL dial
sets the short circuit current (arc-force) during stick welding
to adjust for a soft or crisp arc. Increasing the dial from 10
(soft) to +10 (crisp) increases the short circuit current and
prevents sticking of the electrode to the plate while welding.
This can also increase spatter. It is recommended that the
ARC CONTROL be set to the minimum number without 11. RUN/STOP SWITCH - RUN position energizes
electrode sticking. Start with a setting at 0. the engine prior to starting. STOP position stops the
engine. The oil pressure interlock switch prevents
DOWNHILL PIPE mode: In this mode, the ARC CONTROL battery drain if the switch is left in the RUN position
dial sets the short circuit current (arc-force) during stick and the engine is not operating.
welding to adjust for a soft or a more forceful digging arc
(crisp). Increasing the number from 10 (soft) to +10 (crisp) 12. GLOW PLUG PUSH BUTTON -
increases the short circuit current which results in a more When pushed activates the glow plugs as well as
forceful digging arc. Typically a forceful digging arc is pre- the electric fuel pump for quick starting. Glow plug
ferred for root and hot passes. A softer arc is preferred for fill should not be activated for more than 20 seconds
and cap passes where weld puddle control and deposition continuously.(For Code 11121)
("stacking" of iron) are key to fast travel speeds. It is recom- AUTO BLEED FUNCTION Air will automatically
mended that the ARC CONTROL be set initially at 0. bleed from the fuel system by simply pushing the
GLOW PLUG BUTTON. It is generally not required
CV-WIRE mode: In this mode, turning the ARC CONTROL to crack open fittings in the fuel system to bleed air
clock wise from 10 (soft) to +10 (crisp) changes the arc from the fuel system.(For Code 11121)
from soft and washed-in to crisp and narrow. It acts as an
inductance/pinch control. The proper setting depends on the When pushed activates the glow plugs. Glow plug
procedure and operator preference. Start with a setting of 0. should not be activated for more than 20 seconds
continuously.(For Code 11188, 11275)
5. WELD OUTPUT TERMINALS WITH FLANGE
NUT- Provides a connection point for the electrode and 13. START PUSH BUTTON -
work cables. Output stud covers provided on code 11275 Energizes the starter motor to crank the engine.
and above.
14. IDLER SWITCH- Has two positions as follows:
6. GROUND STUD- Provides a connection point for 1) In the HIGH position, the engine runs at the high
connecting the machine case to earth ground. idle speed controlled by the engine governor.
2) In the AUTO position, the idler operates as follows:
7. 14-PIN CONNECTOR- For attaching wire feeder con- When switched from HIGH to AUTO or after starting
trol cables to the RANGER 305D. Includes contactor clo- the engine, the engine will operate at full speed for
sure circuit, auto-sensing remote control circuit, and 120V approximately 12 seconds and then go to low idle
and 42V power. The remote control circuit operates the speed.
same as the 6 Pin Amphenol. When the electrode touches the work or power is
drawn for lights or tools (approximately 100 Watts
8. 6-PIN CONNECTOR- For attaching optional remote minimum), the engine accelerates and operates at
full speed.
control equipment. Includes auto-sensing remote control
When welding ceases or the AC power load is
circuit.
turned off, a fixed time delay of approximately 12
seconds starts. If the welding or AC power load is
9. WELD TERMINALS CONTROL SWITCH- In the not restarted before the end of the time delay, the
WELD TERMINALS ON position, the output is electrically idler reduces the engine speed to low idle speed.
hot all the time. In the REMOTELY CONTROLLED posi- The engine will automatically return to high idle
tion, the output is controlled by a wire feeder or amptrol speed when there is welding load or AC power load
device, and is electrically off until a remote switch is reapplied.
depressed.

RANGER 305D
B-4 OPERATION B-4
15. ELECTRIC FUEL GAUGE- The electric fuel NOTE: If the unit fails to start repeat step 4 through
gauge gives accurate and reliable indication as to step 7 after waiting 30 seconds
how much fuel is in the fuel tank.
CAUTION
16. ENGINE HOUR METER- Displays the total
time that the engine has been running. This meter Do not allow the starter motor to run continuously
is useful for scheduling prescribed maintenance. for more than 20 seconds.
Do not push the START button while the engine
is running because this can damage the ring
17. ENGINE PROTECTION LIGHT- A warning
gear and/or the starter motor.
indicator light for Low Oil Pressure and/or Coolant
IF the Engine Protection or Battery Charging
Over Temperature. The light is off when the sys-
Lights do not turn off shortly after starting the
tems are functioning properly. The light turns on
engine shut off the engine immediately and deter
when the RUN-STOP switch is in the ON posi-
mine the cause.
tion prior to starting the engine. If the Engine
-----------------------------------------------------------------------
Protection or Battery Charging Lights do not
NOTE: When starting a RANGER 305D for the first
turn off shortly after starting the engine shut off
time, or after and extended period of time of not oper-
the engine immediately and determine the cause.
ating, it will take longer than normal because the fuel
pump has to fill the fuel system.
STARTING THE ENGINE
1. Remove all plugs connected to the AC power STOPPING THE ENGINE
receptacles. Remove all welding and auxiliary power loads and
2. Set IDLER switch to AUTO. allow the engine to run at low idle speed for a few
3. Set the RUN/STOP switch to RUN. minutes to cool the engine.
4. Press Glow Plug Button and hold 5 to 10 seconds.
5. Press and hold both the Glow Plug Button and STOP the engine by placing the RUN-STOP switch in
START button together until the engine starts or for the STOP position.
up to 10 seconds.
6. Release the engine START button immediately NOTE: A fuel shut off valve is located on the fuel pre-
when the engine starts. filter.
7. Release the glow plug button after the Engine
Protection Light turns off or after an additional 5 WELDER OPERATION
seconds maximum.
DUTY CYCLE
8. The engine will run at high idle speed for approxi-
mately 12 seconds and then drop to low idle speed. Duty Cycle is the percentage of time the load is being
Allow the engine to warm up at low idle for several applied in a 10 minute period. For example a 60% duty
minutes before applying a load and/or switching to cycle, represents 6 minutes of load and 4 minutes of no
high idle. Allow a longer warm up time in cold load in a 10 minute period.
weather.
TABLE B.1
TYPICAL RANGER 305D FUEL CONSUMPTION
Kubota D722 Running time for
Gal./Hr (Liters/Hr) 12 gallons-hours
Low Idle - No Load
2450 R.P.M. .29 (1.09) 41.77
High Idle - No Load
3650 R.P.M. .54 (2.06) 22.02
DC Weld Output
250 Amps @ 28 Volts 1.03 (3.91) 11.62
DC Weld Output
300 Amps @ 29 Volts 1.18 (4.47) 10.16

9,500 Watts 1.16 (4.38) 10.37

7,000 Watts .96 (3.63) 12.50

3,000 Watts .70 (2.67) 17.03

RANGER 305D
B-5 OPERATION B-5
The Ranger 305D can be used with a broad range of DC It is recommended that the ARC CONTROL be set to the
stick electrodes. The MODE switch provides two stick minimum number without electrode sticking. Start with
welding settings as follows: the dial set at 0.

Constant Current (CC-STICK) Welding TIG WELDING


The CC-STICK position of the MODE switch is designed The TOUCH START TIG setting of the MODE switch is
for horizontal and vertical-up welding with all types of elec- for DC TIG (Tungsten Inert Gas) welding. To initiate a
trodes, especially low hydrogen. The output CONTROL weld, the CONTROL dial is first set to the desired current
dial adjusts the full output range for stick welding. and the tungsten is touched to the work. During the time
the tungsten is touching the work there is very little volt-
The ARC CONTROL dial sets the short circuit current age or current and, in general, no tungsten contamina-
(arc-force) during stick welding to adjust for a soft or crisp tion. Then, the tungsten is gently lifted off the work in a
arc. Increasing the number from -10(soft) to +10(crisp) rocking motion, which establishes the arc.
increases the short circuit current and prevents sticking of
the electrode to the plate while welding. This can also When in the TOUCH START TIG mode and when a
increase spatter. It is recommended that the ARC CON- Amptrol is connected to the 6-Pin connector the OUT-
TROL be set to the minimum number without electrode PUT dial is used to set the maximum current range of the
sticking. Start with the dial set at 0. current control of the Amptrol.

DOWNHILL PIPE Welding The ARC CONTROL is not active in the TIG mode. To
This slope controlled setting is intended for "out-of-posi- STOP a weld, simply pull the TIG torch away from the
tion" and "down hill" pipe welding where the operator work. When the arc voltage reaches approximately 30
would like to control the current level by changing the arc Volts the arc will go out and the machine will reset the
length. The output CONTROL dial adjusts the full output current to the Touch Start level. To reinitiate the arc,
range for pipe welding. The ARC CONTROL dial sets the retouch the tungsten to the work and lift. Alternatively,
short circuit current (arc-force) during stick welding to the weld can be stopped by releasing the Amptrol or arc
adjust for a soft or more forceful digging arc (crisp). start switch.
Increasing the number from -10(soft) to +10(crisp)
increases the short circuit current which results in a more The RANGER 305 D can be used in a wide variety of DC
forceful digging arc.Typically a forceful digging arc is pre- TIG welding applications. In general the Touch Start
ferred for root and hot passes. A softer arc is preferred for feature allows contamination free starting without the use
fill and cap passes where weld puddle control and deposi- of a Hi-frequency unit. If desired, the K930-2 TIG Module
tion (stacking of iron) are key to fast travel speeds. This can be used with the RANGER 305 D. The settings are
can also increase spatter. TABLE B.2 for reference.

TYPICAL CURRENT RANGES (1) FOR TUNGSTEN ELECTRODES(2)


Tungsten Electrode DCEN (-) DCEP (+) Approximate Argon Gas Flow TIG TORCH
Diameter in. (mm) Flow Rate C.F.H. ( l /min.) Nozzle Size (4), (5)

1%, 2% Thoriated 1%, 2% Thoriated Aluminum Stainless Steel


Tungsten Tungsten

.010 (.25) 2-15 (3) 3-8 (2-4) 3-8 (2-4) #4, #5, #6
0.020 (.50) 5-20 (3) 5-10 (3-5) 5-10 (3-5)
0.040 (1.0) 15-80 (3) 5-10 (3-5) 5-10 (3-5)

1/16 (1.6) 70-150 10-20 5-10 (3-5) 9-13 (4-6) #5, #6

3/32 (2.4) 150-250 15-30 13-17 (6-8) 11-15 (5-7) #6, #7, #8
1/8 (3.2) 250-400 25-40 15-23 (7-11) 11-15 (5-7)

5/32 (4.0) 400-500 40-55 21-25 (10-12) 13-17 (6-8) #8, #10
3/16 (4.8) 500-750 55-80 23-27 (11-13) 18-22 (8-10)
1/4 (6.4) 750-1000 80-125 28-32 (13-15) 23-27 (11-13)

(1) When used with argon gas. The current ranges shown must be reduced when using argon/helium or pure helium shielding gases.
(2) Tungsten electrodes are classified as follows by the American Welding Society (AWS):
Pure EWP
1% Thoriated EWTh-1
2% Thoriated EWTh-2
Though not yet recognized by the AWS, Ceriated Tungsten is now widely accepted as a substitute for 2% Thoriated Tungsten in AC and DC applications.
(3) DCEP is not commonly used in these sizes.
(4) TIG torch nozzle "sizes" are in multiples of 1/16ths of an inch:
# 4 = 1/4 in. (6 mm)
# 5 = 5/16 in. (8 mm)
# 6 = 3/8 in. (10 mm)
# 7 = 7/16 in. (11 mm)
# 8 = _ in. (12.5 mm)
#10 = 5/8 in. (16 mm)
(5) TIG torch nozzles are typically made from alumina ceramic. Special applications may require lava nozzles, which are less prone to breakage, but cannot withstand high temperatures
and high duty cycles.

RANGER 305D
B-6 OPERATION B-6

RANGER 305 D settings when using the K930-2 TIG Module with ARC GOUGING
an Amptrol or Arc Start Switch: The RANGER 305D can be used for limited arc goug-
Set the MODE Switch to the TOUCH START TIG setting. ing. For optimal performance, set the MODE switch to
CC-STICK and the ARC CONTROL to +10.
Set the "IDLER" Switch to the "AUTO" position.
Set the OUTPUT CONTROL knob to adjust output
Set the "WELDING TERMINALS" switch to the "REMOTELY current to the desired level for the gouging electrode
CONTROLLED" position. This will keep the "Solid State" con- being used according to the ratings in the following
tactor open and provide a "cold" electrode until the Amptrol or Table.
Arc Start Switch is pressed.
Carbon Diameter Current Range (DC, electrode
When using the TIG Module, the OUTPUT control on the positive)
RANGER 305 D is used to set the maximum range of the CUR-
RENT CONTROL on the TIG Module or an Amptrol if connected 1/8" 60-90 Amps
to the TIG Module.
5/32" 90-150 Amps
WIRE WELDING-CV
Connect a wire feeder to the RANGER 305 D according to the 3/16" 200-250 Amps
instructions in INSTALLATION INSTRUCTIONS Section.

The RANGER 305 D in the CV-WIRE mode, permits it to be used


with a broad range of flux cored wire (Innershield and
Outershield) electrodes and solid wires for MIG welding (gas
metal arc welding). Welding can be finely tuned using the ARC
CONTROL. Turning the ARC CONTROL clockwise from 10
(soft) to +10 (crisp) changes the arc from soft and washed-in to
crisp and narrow. It acts as an inductance/pinch control. The
proper setting depends on the procedure and operator prefer-
ence. Start with the dial set at 0.

Listed below are some wires suitable for use on this machine:

Innershield - NR-311, NS-3M, NR-207, NR-203 Ni 1%,


NR-212.
Outershield - 0S-70, 0S-71M, 0S-71 ELITE.
Solid wires for MIG welding - .035 (0.9 mm), and
.045 (1.1 mm), Super Arc L-50 and L-56, .035 (0.9 mm) and
.045 (1.1 mm) Blue Max MIG 308 LS.

Contact your local authorized Lincoln Electric Distributor or the


Lincoln Electric Company for specific wires used on certain appli-
cations with this machine.

RANGER 305D
B-7 OPERATION B-7
AUXILIARY POWER: The 120 V auxiliary power receptacles should only be
used with three wire grounded type plugs or approved
If a GFCI receptacle is tripped, See the MAINTE- double insulated tools with two wire plugs. The current
NANCE section for detailed information on testing and rating of any plug used with the system must be at
resetting the GFCI receptacle. least equal to the current capacity of the associated
receptacle.
Start the engine and set the IDLER control switch to
the desired operating mode. Full power is available
regardless of the welding control settings providing no NOTE: The 240 V receptacle has two circuits, each of
welding current is being drawn. which measure 120 V to neutral but are of opposite
polarities and cannot be paralleled.
The auxiliary power of the RANGER 305D consists of
two 20 Amp-120 VAC GFCI (5-20R) duplex recepta- Simultaneous Welding and Auxiliary Power Loads
cles and one 50 Amp 120/240 VAC (14-50R) recepta- The above auxiliary power ratings are with no welding
cle. The 240 VAC receptacle can be split for single load. Simultaneous welding and power loads are
phase 120 VAC operation. The auxiliary power capac- specified in the following table. The permissible cur-
ity is 10,000 watts Peak, 9500 Watts continuous of 60 rents shown assume that current is being drawn from
Hz, single phase power. The auxiliary power capacity either the 120 VAC or 240 VAC supply (not both at the
rating in watts is equivalent to volt-amperes at unity same time).
power factor. The max permissible current of the 240
VAC output is 44 Amps. The 240 VAC output can be
split to provide two separate 120 VAC outputs with a
max permissible current of 44 Amps per output to two
separate 120 VAC branch circuits (these circuits can-
not be paralleled). Output voltage is within 10% at
all loads up to rated capacity. All auxiliary power is
protected by circuit breakers.

RANGER 305D Simultaneous Welding and Power Loads


Welding Permissible Power-Watts Permissible Auxiliary
Output-Amps (Unity Power Factor) Current in -Amps

@ 240 VAC
0 9000 44
100 7500 31
150 5800 24
200 4500 19
250 2800 12
300 700 3
* Each duplex receptacle is limited to 20 amps.
** Not to exceed 44A per 120 VAC branch circuit when splitting the 240 VAC output.
RANGER 305D Extension Cord Length Recommendations
(Use the shortest length extension cord possible sized per the following table.)
Current Voltage Load Maximum Allowable Cord Length in ft. (m) for Conductor Size
(Amps) Volts (Watts) 14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG
15 120 1800 30 (9) 40 (12) 75 (23) 125 (38) 175 (53) 300 (91)
20 120 2400 30 (9) 50 (15) 88 (27) 138 (42) 225 (69)
15 240 3600 60 (18) 75 (23) 150 (46) 225 (69) 350 (107) 600 (183)
20 240 4800 60 (18) 100 (30) 175 (53) 275 (84) 450 (137)
44 240 9500 50 (15) 90 (27) 150 (46) 225 (69)
Conductor size is based on maximum 2.0% voltage drop.

RANGER 305D
C-1 ACCESSORIES C-1

FIELD INSTALLED OPTIONS / K802-N POWER PLUG KIT


ACCESSORIES Provides four 120 volt plugs rated at 20 amps each
and one dual voltage, full KVA plug rated at 120/240
K957-1 HEAVY DUTY, TWO WHEEL TRAILER FOR volts, 50 amps.
SMALL WELDERS
For road, off-road and in-plant and yard towing. K802-R POWER PLUG KIT
(For highway use, consult applicable federal, state Provides four 120 volt plugs rated at 15 amps each
and local laws regarding requirements for brakes, and one dual voltage, full KVA plug rated at 120/240
lights, fenders, etc.).Order: volts, 50 amps.

T12153-9 50 AMP, 120/240 V POWER PLUG


K957-1 Trailer
K958-1 Ball Hitch
K1816-1 FULL KVA ADAPTER KIT
K958-2 Lunette Eye Hitch
Plugs into the 120/240V NEMA 14-50R receptacle on
K959-2 Fender & Light Kit
the case front (which accepts 4-prong plugs) and
K965-1 Cable Storage Rack
converts it to a NEMA 6-50R receptacle, (which
accepts 3-prong plugs.) For connection of Lincoln
K1789-1 ROLL CAGE - Gives added damage protection. equipment with NEMA 6-50R plug.

K1898-1 SPARK ARRESTOR TIG Welding


K1783-9 TIG Torch PTA-26V (25ft.)
K963-3 Hand Amptrol
K704 ACCESSORY SET - Includes 35 ft. (10m) of K870 Foot Amptrol
electrode cable and 30 ft. (9.1m) of work cable, head-
shield, work clamp electrode holder. Cables are rated KP509 Magnum Parts Kit
at 400 amps, 100% duty cycle.
Spool Gun
K857 25 ft (7.6m) or K857-1 100 ft. (30.4m) K1692-2 Prince XL Spool Gun (25ft.)
REMOTE CONTROL
Portable control provides same dial range as the out- K487-25 Magnum Spool Gun
put control on the welder. Has a convenient 6 pin plug K488 Magnum Control Module
for easy connection to the welder.
K691-10 Input Cable)
K2174-1 COLD WEATHER OPERATIONS KIT-
Provides starting aid and enhancement in extreme
cold weather. Includes radiator grill cover, oil pan
heater, coolant Lester and all hardware required for
installation.

RANGER 305D
D-1 MAINTENANCE D-1

SAFETY PRECAUTIONS KUBOTA D722 DIESEL ENGINE


FREQUENCY MAINTENANCE REQUIRED
FILL FUEL TANK.
WARNING CHECK OIL LEVEL.
CHECK COOLANT LEVEL.
Have qualified personnel do all maintenance CHECK AIR CLEANER ELE-
and troubleshooting work. MENT AND HOUSING FOR
DIRTY, LOOSE OR DAMAGED
Turn the engine off before working inside the PARTS.
DAILY OR BEFORE CHECK AIR INTAKE HOSE
machine or servicing the engine. STARTING ENGINE FOR CRACKS OR LOOSE
CONNECTIONS.
Remove guards only when necessary to CHECK AIR INTAKE/EXHAUST
perform maintenance and replace them when AREAS & RADIATOR FOR
DIRT. CLEAN AS NECESSARY.
the maintenance requiring their removal is CHECK ALTERNATOR BELT
complete. If guards are missing from the TENSION AND WEAR.
machine, obtain replacements from a Lincoln
Service Intervals
Distributor. (See Operating Manual Parts List.) Observe the following for service and maintenance. The lubricating
oil change intervals listed in the table below are for Classes CF,CE
Read the Safety Precautions in the front of this and CD lubricating oils of API classification with a low sulfur fuel in
manual and in the Engine Owners Manual before use. If the CF-4 or CG-4 lubricating oil is used with a high-sulfur
fuel, change the lubricating oil at shorter intervals than recommend-
working on this machine. ed in the table below depending on the operating condition.

Keep all equipment safety guards, covers, and


Intervals Items
devices in position and in good repair. Keep
hands, hair, clothing, and tools away from the Every 50 hours Check of fuel pipes and clamp bands. @
gears, fans, and all other moving parts when Every 75 hours Change of engine oil
starting, operating, or repairing the equipment. Every 100 hours *1 @
Inspect/Clean air cleaner element
and Vacuator valve.
Routine Maintenance Cleaning of fuel filter.
Check the battery electrolyte level.
Check the fan belt tightness.
At the end of each days use, refill the fuel tank to Every 150 hours Check the radiator and hose clamps.
minimize moisture condensation in the tank. Running Replacement of oil filter cartridge
out of fuel tends to draw dirt into the fuel system. Check the intake air lines. @
Every 200 hours Replacement of Air Filter element. *1,*2 @
Also, check the crankcase oil level and add oil if Every 400 hours @
Replacement of fuel filter element.
indicated. Every 500 hours Removal of of sediment in fuel tank.
Cleaning of water jacket (radiator
ENGINE MAINTENANCE COMPONENTS interior).
Replacement of fan belt.
KUBOTA D722 DIESEL ENGINE Every 1 or 2 months Recharging of Battery.
Every 800 hours Check of valve clearance. *3 @
Every 1500 hours Check the fuel injection nozzle injec- *3 @
ITEM MAKE AND PART NUMBER tion pressure.
Every 3000 hours Check of injection pump. *3 @
Check of fuel injector timer. *3 @
OIL FILTER KUBOTA 70000-15241 Every 2 years Replacement of battery
Replacement of radiator hoses and
clamp band.
AIR FILTER ELEMENT DONALDSON P822686
Replacement of fuel pipes and
clamps.
FUEL FILTER ELEMENT KUBOTA 15231-43560 Change the radiator coolant.(L.L.C.) *4
Replacement of intake air line. @
BATTERY KUBOTA GROUP 58, 550 CCA IMPORTANT
These jobs should be done after the first 50 hours of operation.
BELT KUBOTA 15881-97011 *1 Air cleaner should be inspected/cleaned more often in dusty conditions than
the normal conditions.
GLOW PLUGS KUBOTA 16851-65512 *2 Follow Service Instructions and Installation Tips for air cleaner in
Section D.
*3 Consult your local KUBOTA Dealer for this service.
INLINE FUEL FILTER KUBOTA 12581-43012 *4 Replace only if necessary.
@ All these markings are registered as emission related critical parts by KUB-
OTA in the U.S. EPA nonroad emission regulation. As the engine owner,
you are responsible for the performance of the required maintenance on
the according to the above instruction.
Please see Engine Owners Manual for Warranty Statement in detail.

RANGER 305D
D-2 MAINTENANCE D-2

Engine Oil Change Oil Filter Change


Drain the engine oil while the engine is warm to Drain the oil.
assure rapid and complete draining. It is recommend-
ed that each time the oil is changed the oil filter be Remove the oil filter with an oil filter wrench and
changed as well. drain the oil into a suitable container. Discard the
used filter. Note: Care should be taken during filter
Be sure the unit is off. Disconnect the negative bat- removal to not disrupt or damage in any way the fuel
tery cable to ensure safety. lines.

Locate oil drain hose and valve in bottom of base Clean the filter mounting base and coat the gasket
and pull through the hole in the battery access panel of the new filter with clean engine oil.
on the welder.
Screw the new filter on by hand until the gasket con-
Remove the cap from the drain valve. Push valve in tacts the mounting base. Using an oil filter wrench,
and twist counterclockwise. Pull to open and drain tighten the filter an additional 1/2 to 7/8 of a turn.
the oil into a suitable container for disposal. Refill the crankcase with the specified amount of the
recommended engine oil. Reinstall the oil filler cap
Close the drain valve by pushing in and twisting and tighten securely.
clockwise. Replace the cap.
Start the engine and check for oil filter leaks.
Re-fill the crankcase to the upper limit mark on the
dipstick with the recommended oil (see engine oper- Stop the engine and check the oil level. If neces-
ation manual OR engine service items decal OR sary, add oil to the upper limit mark on the dipstick.
below). Replace and tighten the oil filler cap secure-
ly.

Push oil drain hose and valve back into unit, re-con-
nect negative battery cable, and close doors and WARNING
engine top cover before restarting unit.Wash your
hands with soap and water after handling used Never use gasoline or low flash point solvents
motor oil. Please dispose of used motor oil in a for cleaning the air cleaner element. A fire or
manner that is compatible with the environment. explosion could result.
We suggest you take it in a sealed container to your
local service station or recycling center for reclama-
CAUTION
tion. DO NOT throw it in the trash; pour it on the Never run the engine without the air cleaner.
ground or down a drain. Rapid engine wear will result from contaminants,
such as dust and dirt being drawn into the
Engine Oil Refill capacities engine.
Without oil filter replacement: ------------------------------------------------------------------------
3.3 U.S. Quart. (2.7 Imp Quart, 3.2 liter) AIR CLEANER

With oil filter replacement: The diesel engine is equipped with a dry type air filter.
3.4 U.S. Quart. (3.0 Imp Quart, 3.2 liter) Never apply oil to it. Service the air cleaner as follows:

Use motor oil designed for diesel engines that meets Replace the element at least every 200 hours of
requirements for API service classification operation and sooner under dusty conditions.
CC/CD/CE/CF/CF-4/CG-4 or CH-4.
ACEA E1/E2/E3. Always check the API service label
on the oil container to be sure it includes the letters
indicated. (Note: An S-grade oil must not be used in a
diesel engine or damage may result. It IS permissible
to use an oil that meets S and C grade service classifi-
cations.)
SAE 10W30 is recommended for general, all tempera-
ture use, 5F to 104F (-15C to 40C).
See engine owners manual for more specific informa-
tion on oil viscosity recommendations.

RANGER 305D
D-3 MAINTENANCE D-3

Service Instructions & Installation Tips


For Engine
F Air Filter

1 Release the
5 Check the Old Donaldson filters with RadialSeal Sealing
Technology are self-aligning, self-centering,
Seal Carefully Filter for Leak Clues and self-sealing. A new filter has a dry
Unlatch and remove the service Visually inspect the old filter for any signs
lubricant to aid installation. The critical
cover of the air cleaner. Make of leaks. A streak of dust on
sealing area will stretch slightly, adjust
certain the latches are folded the clean side of the filter
itself and distribute the sealing pressure
back against the cover so that is a telltale sign.
evenly. To complete a tight seal, apply
they don t hinder filter Remove any cause
pressure by hand at the outer rim of the
removal/installation. Most latches of leaks before
filter, not the flexible center. (Avoid
are spring loaded to fold back when open. installing new
pushing on the center of the urethane end
The filter fits tightly over the outlet tube, filter. cap.) No cover pressure is required to hold
creating the critical seal on the inside
the seal. Again, do NOT use the service
diameter of the filter endcap. The filter
should be removed gently to reduce the
amount of dust dislodged. There will be
6 Inspect the New
Filter for Damage
Inspect the new filter carefully,
cover to push the filter into place!

When the filter in is place, put the service


some initial resistance, similar to breaking cover back on, making sure the Vacuator
paying attention to the inside of
the seal on a jar. Gently move the end of the Valve points down. Inspect the Vacuator
the open end,
filter back and forth to break the seal. Valve for cracks or dust hang-ups to insure
which is the
that it is functioning properly. Re-fasten
sealing area.

2 Avoid Dislodging the latches.


NEVER install
Dust from the Filter a damaged filter.
Gently pull the
filter off the outlet
tube and out of the
8 Check Connections
for Tight Fit

7 Insert the New Make sure that all clamps, bolts, and
housing. Avoid
connections in the entire air intake system
knocking the filter RadialSeal Filter are tight. Check for holes in piping, and
against the housing. by Hand repair if needed.
Insert carefully. Seat the new filter by hand,

3 Clean Sealing Surface


of the Outlet Tube
Use a clean cloth to wipe the sealing
making certain it is completely into the air
cleaner housing before latching the cover in
place. If the cover hits the filter before it is
surface. Dust on the outside diameter of the fully in place, remove the cover and push
outlet tube could hinder (by hand) the
an effective seal filter further into
and cause leakage. the air cleaner
Make sure that all and try again.
contaminant is The cover
removed before the should go on
new filter is inserted. with no extra force.

Never use the latches on the cover to force

4 Clean the Inside of


the Outlet Tube
Carefully wipe the inside
the filter into the air cleaner! It is tempting
to assume the cover will do the job of
seating the filter but it will not! Using the
of the outlet tube latches to push the filter in could cause
with a clean cloth. damage to the housing and will void the
Dirt accidently warranty.
transferred to the
inside of the outlet
tube will reach the
engine and cause wear.
(Engine manufacturers says that it takes
only a few grams of dirt to dust an
engine!) Be careful not to damage the
sealing area on the tube.

RANGER 305D
D-4 MAINTENANCE D-4
COOLING SYSTEM FUEL
WARNING At the end of each days use, refill the fuel tank to min-
imize moisture condensation and dirt contamination in
HOT COOLANT can burn skin. the fuel line. Do not overfill; leave room for the fuel to
expand.
Do not remove cap if radiator is
hot. Use only fresh, No. 2 grade DIESEL fuel. Do not use
kerosene.

------------------------------------------------------------------------ See the Engine Operator's Manual for instructions on


Check the coolant level by observing the level in the replacing the fuel filter.
radiator and recovery bottle. Add 50/50 antifreeze /
water solution if the level is close to or below the
BLEEDING THE FUEL SYSTEM
"LOW" mark. do not fill above the "FULL" mark.
Remove radiator cap and add coolant to radiator. Fill
You may need to bleed air from the fuel system if the
up to the top of the tube in the radiator filler neck
fuel filter or fuel lines have been detached, the fuel
which includes a connecting hose coming from the
tank has been ran empty or after periods of long stor-
thermostat housing.
age. It is recommended that the fuel shutoff valve be
closed during periods of non-use.
To drain the coolant, open the petcock at the bottom
of the radiator. Open the radiator cap to allow com-
(For Code 11121)
plete drainage. (Tighten the petcock and refill with a
The Kubota D722 engine supplied with this welder is
50/50 antifreeze/water solution.) Use an automotive
equipped with an automatic bleeding mechanism that
grade (low silicate) ethylene glycol antifreeze. The
functions when the electric fuel pump is actuated. It is
cooling system capacity is 3.85 quarts (3.6L.).
generally not necessary to open a vent screw or fuel
Squeeze upper and lower radiator hoses while filling
line fitting to bleed the fuel system.
to bleed air from system coolant. Replace and tighten
the radiator cap.
(For Code 11188, 11275)
The Kubota D722 engine supplied with this welder is
CAUTION equipped with an automatic bleeding mechanism that
helps purge the air from the mechanical fuel pump
Always premix the antifreeze and clean tap water
system. It is generally not necessary to open a vent
before adding to the radiator. It is very important
screw or fuel line fitting to bleed the fuel system.
that a precise 50/50 solution be used with this
Operate the priming lever on the pump to assist start-
engine year round. This gives proper cooling dur-
ing after extended periods of non-use or out of fuel
ing hot weather and freezing protection to -34 F (-
conditions.
37 C).

Cooling solution exceeding 50% ethylene glycol


WARNING
can result in engine overheating and damage to
To avoid personal injury, do not bleed a hot
the engine. Coolant solution must be premixed
engine. This could cause fuel to spill onto a hot
before adding to radiator.
exhaust manifold, creating a danger of fire.
------------------------------------------------------------------------
------------------------------------------------------------------------
Bleed the fuel system as follows:
Periodically remove the dirt from the radiator fins.
1. Fill the fuel tank with fuel.
Periodically check the fan belt and radiator hoses.
2. Open the fuel shut off valve (vertical position of
Replace if signs of deterioration are found.
handle) on the Fuel Filter.
3. Press and hold the glow plug button for 10 to 20
TIGHTENING THE FAN BELT seconds.(For Code 11121)
3a. Crank the engine by pressing the start button for
If the fan belt is loose, the engine can overheat and 45 seconds. (For Code 11188, 11275)
the battery lose its charge. Check tightness by press- 4. Check to see that fuel is flowing through both fuel
ing on the belt midway between the pulleys. It should filters
deflect about .25 in. under a load of 20 lbs. (9 Kg) (6 5. Follow the normal STARTING procedures.
mm).

RANGER 305D
D-5 MAINTENANCE D-5
CLEANING THE BATTERY
FUEL FILTER
Keep the battery clean by wiping it with a damp cloth
1. Check the fuel filter and fuel pre-filter for water when dirty. If the terminals appear corroded, discon-
accumulation or sediment. nect the battery cables and wash the terminals with an
ammonia solution or a solution of 1/4 pound (0.1113
2. Replace the fuel filter if it is found with excessive kg) of baking soda and 1 quart (0.9461) of water. Be
water accumulation or sediment. Empty fuel pre-fil- sure the battery vent plugs (if equipped) are tight so
ter. that none of the solution enters the cells.
After cleaning, flush the outside of the battery, the bat-
OVERSPEED IS HAZARDOUS tery compartment, and surrounding areas with clear
The maximum allowable high idle speed for this water. Coat the battery terminals lightly with petroleum
machine is 3650 RPM, no load. Do NOT tamper jelly or a non-conductive grease to retard corrosion.
with governor components or setting or make any Keep the battery clean and dry. Moisture accumula-
other adjustments to increase the maximum tion on the battery can lead to more rapid discharge
speed. Severe personal injury and damage to the and early battery failure.
machine can result if operated at speeds above
maximum.
CHECKING THE ELECTROLYTE LEVEL
ENGINE ADJUSTMENT If battery cells are low, fill them to the neck of the filler
Adjustments to the engine are to be made only by a hole with distilled water and recharge. If one cell is
Lincoln Service Center or an authorized Field Service low, check for leaks.
Shop.

CHARGING THE BATTERY


BATTERY MAINTENANCE When you charge, jump, replace, or otherwise con-
To access the battery, Disconnect the Negative and nect battery cables to the battery, be sure the polarity
then Positive battery cables. Remove the 2 screws is correct. Improper polarity can damage the charging
from the battery door using a screwdriver or a 3/8" circuit. The RANGER 305D positive (+) battery termi-
socket. Remove the 2 nuts from the battery bracket nal has a red terminal cover.
using a 7/16 wrench or socket. Slide the battery out
and remove from welder If you need to charge the battery with an external
charger, disconnect the negative cable first, then the
WARNING positive cable before you attach the charger leads.
After the battery is charged, reconnect the positive
battery cable first and the negative cable last. Failure
GASES FROM BATTERY can explode. to do so can result in damage to the internal charger
Keep sparks, flame and cigarettes
components.
away from battery. Follow the instructions of the battery charger manu-
facturer for proper charger settings and charging time.
To prevent EXPLOSION when:
INSTALLING A NEW BATTERY disconnect
negative cable from old battery first and con- SERVICING OPTIONAL SPARK
nect to new battery last. ARRESTOR
CONNECTING A BATTERY CHARGER Clean every 100 hours.
remove battery from welder by disconnecting
negative cable first, then positive cable and WARNING
battery clamp. When reinstalling, connect
negative cable last. Keep well ventilated.
MUFFLER MAY BE HOT
USING A BOOSTER connect positive lead to
battery first then connect negative lead to neg- ALLOW ENGINE TO COOL BEFORE INSTALLING
ative battery lead at engine foot. THE SPARK ARRESTER!
BATTERY ACID can burn eyes and
skin. DO NOT OPERATE ENGINE WHILE INSTALLING
Wear gloves and eye protection THE SPARK ARRESTER!
and be careful when working near
battery.
Follow instructions printed on battery.
RANGER 305D
D-6 MAINTENANCE D-6

WELDER / GENERATOR GFCI RECEPTACLE TESTING AND RESET-


MAINTENANCE TING PROCEDURE

The GFCI receptacle should be properly tested at


STORAGE: Store the RANGER 305D in clean, dry least once every month or whenever it is tripped. To
protected areas. properly test and reset the GFCI receptacle:

CLEANING: Blow out the generator and controls peri- If the receptacle has tripped, first carefully remove
odically with low pressure air. Do this at least once a any load and check it for damage.
week in particularly dirty areas. If the equipment has been shut down, it must be
restarted.
BRUSH REMOVAL AND REPLACEMENT: Its nor- The equipment needs to be operating at high idle
mal for the brushes and slip rings to wear and darken speed and any necessary adjustments made on the
slightly. Inspect the brushes when a generator over- control panel so that the equipment is providing at
haul is necessary. least 80 volts to the receptacle input terminals.
The circuit breaker for this receptacle must not be
tripped. Reset if necessary.
CAUTION Push the "Reset" button located on the GFCI recep-
tacle. This will assure normal GFCI operation.
Plug a night-light (with an "ON/OFF" switch) or other
Do not attempt to polish slip rings while the product (such as a lamp) into the GFCI receptacle
engine is running. and turn the product "ON".
Push the "Test" button located on the GFCI recepta-
cle. The night-light or other product should go
"OFF".
WARNING Push the "Reset" button, again. The light or other
product should go "ON" again.
Service and Repair should only be performed by
Lincoln Electric Factory Trained Personnel. If the light or other product remains "ON" when the
Unauthorized repairs performed on this equip- "Test" button is pushed, the GFCI is not working prop-
ment may result in danger to the technician and erly or has been incorrectly installed (miswired). If
machine operator and will invalidate your factory your GFCI is not working properly, contact a qualified,
warranty. For your safety and to avoid Electrical certified electrician who can assess the situation,
Shock, please observe all safety notes and pre- rewire the GFCI if necessary or replace the device.
cautions.

RANGER 305D
E-1 TROUBLESHOOTING E-1

HOW TO USE TROUBLESHOOTING GUIDE

WARNING
Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician and
machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical
Shock, please observe all safety notes and precautions detailed throughout this manual.
__________________________________________________________________________
This Troubleshooting Guide is provided to help you Step 3. RECOMMENDED COURSE OF ACTION
locate and repair possible machine malfunctions. This column provides a course of action for the
Simply follow the three-step procedure listed below. Possible Cause, generally it states to contact your
local Lincoln Authorized Field Service Facility.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled PROBLEM (SYMP- If you do not understand or are unable to perform the
TOMS). This column describes possible symptoms Recommended Course of Action safely, contact your
that the machine may exhibit. Find the listing that local Lincoln Authorized Field Service Facility.
best describes the symptom that the machine is
exhibiting.

Step 2. POSSIBLE CAUSE.


The second column labeled POSSIBLE CAUSE lists
the obvious external possibilities that may contribute
to the machine symptom.

CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

RANGER 305D
E-2 TROUBLESHOOTING E-2
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
Major Physical or Electrical Damage 1. Contact your local Lincoln
is Evident. Authorized Field Service
Facility.

Engine will not "crank". 1. Battery is low, Charge Battery.


2. Loose battery cable connections.
Inspect, clean and tighten terminals.
3. Faulty engine starter motor.
Contact authorized local Engine
Service Shop.

Engine will "crank" but not start. 1. Fuel shut off valve on Main Fuel
Filter in the OFF position. Open
valve (vertical) position of handle.
2. Fuel Filters dirty/clogged. Check
and replace main filter element
and/or Inline Fuel Filter.
3. Out of fuel. Fill tank and bleed fuel
system.
4. High coolant temperature or low
oil pressure. (indictor lights lit) If all recommended possible areas
Check oil and coolant levels. Fill if of misadjustment have been
required. Check for loose or bro- checked and the problem persists,
ken fan belt. Contact your local Lincoln
5. Faulty fuel shutdown solenoid. Authorized Field Service Facility.
Check that shutdown solenoid is
functioning properly and not bind-
ing/ contact authorized engine
service shop.
6. Faulty fuel pump. Check for fuel
flow through filters. Contact autho-
rized local Engine Service Shop.

Engine shuts down shortly after 1. High coolant temperature or low


starting. oil pressure. (indictor light lit)
Change oil and oil filters and fill to
proper level. Check and fill coolant
level. Check for loose or broken
fan belt. Start engine and look for
leaks.
2. Faulty oil pressure switch or other
engine component. Contact
authorized local Engine Service
Shop.
3. Faulty engine protection relay.

CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D
E-3 TROUBLESHOOTING E-3
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
Engine shuts down while under a 1. High radiator coolant tempera-
load. ture. Reduce load if it is exceed-
ing machine rating. Add coolant
to system if low. Clean fins on
radiator if dirty. Tighten fan belt if
loose. Remove objects blocking
or close to intake openings on
both sides of base and exhaust
end (case back).

Engine runs rough. 1. Dirty fuel or air filters. Inspect and


clean/replace filters as needed.
Inspect and clean/replace filters
as needed.
2. Water in fuel. If water found in
tank. Empty fuel tank and refill
then purge fuel lines.

Battery does not stay charged. 1. Faulty battery. Replace.


Engine alternator trouble light is on 2. Loose connections at battery or
while machine is running. alternator. Clean and tighten con-
nections. If all recommended possible areas of
3. Faulty engine alternator or charg- misadjustment have been checked
er module. Consult authorized and the problem persists, Contact
Engine Service Shop. your local Lincoln Authorized
Field Service Facility.
Engine will not idle down to low 1. Idler switch in High idle position.
speed. Set switch to Auto.
2. External load on welder or auxil-
iary power. Remove all external
loads.
3. Faulty PC board or idler sole-
noid.

Engine will not go to high idle when 1. Poor work lead connection to
attempting to weld. work. Make sure work clamp is
tightly connected to clean base
metal.
2. "Contactor" switch is in wrong
position. Set to "Welding On" when
welding without a control cable.
Refer to Operations chapter for prop-
er use of this switch.
3. Faulty PC board. Low idle speed
set to low.

CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D
E-4 TROUBLESHOOTING E-4
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
Engine will not go to high idle when 1. Auxiliary power load is less than
using auxiliary power. 100 watts. Idler may not respond
with less than a 100 watt load. Set
idler to "High".
2. Faulty PC board.

Engine will not go to high idle 1. Faulty idler solenoid. Check for
under weld or auxiliary loading. bent linkage or broken spring

Engine does not develop full 1. Fuel filter clogged, Replace.


power. Engine runs rough. 2. Air filter clogged, clean or replace.
3. High idle setting incorrect, check
and adjust if required.
4. Valves out of adjustment.
5. Fuel contaminated with water or
sediment. Check fuel pre-filter
and empty of water, bleed fuel
system. Replace fuel in tank if
needed.

Engine will not go to high idle when 1. Broken spring on Idle Solenoid,
attempting to weld or using auxil- solenoid linkage binding, Faulty
iary power. Switching to manual PC board, low idle speed set too If all recommended possible areas
high idle does not work. low on idle solenoid. of misadjustment have been
checked and the problem persists,
Engine will not shut off. 1. Fuel Shutdown solenoid not Contact your local Lincoln
functioning properly / linkage Authorized Field Service Facility.
binding. Stop engine by shutting
off valve located on main fuel fil-
ter. Contact authorized local
Engine Service Shop.

Engine does not develop full power. 1. Fuel filter dirty/clogged. Replace.
Low weld and auxiliary output. 2. Air filter dirty/clogged. Replace
Engine runs rough. Air Filter Element.
3. Fouled fuel injector(s). Contact
authorized Engine Service Shop.
4. Fuel contaminated with water.
Check Main Filter Bowl and Inline
Fuel filters for water. Clean and
replace as needed. Replace fuel
in tank.
5. Cracked or loose fuel hose.
Replace hose and tighten
clamps.
6. Valves out of adjustment. Contact
authorized local Engine Service
Shop.

CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D
E-5 TROUBLESHOOTING E-5
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
No welding power output. 1. Poor work lead connection to
work. Make sure work clamp is
tightly connected to clean base
metal.
2. "Weld Terminals" switch in wrong
position. Place switch in "Weld
Terminals On" position when
welding without control cable.
3. Faulty PC board or welder alterna-
tor.

Welder has output but no control. 1. Poor remote/control cable connec-


tion to 6-pin or 14-pin connector.
Check connections.
2. Faulty remote cable or faulty wire
feeder or wire feeder cable.
Replace if necessary.
3. Faulty control potentiometer or PC
board.

If all recommended possible areas


Wire feeder does not work when 1. Wire Feeder Power circuit breaker of misadjustment have been
control cable is connected to 14 pin open. Check 42V and 120V checked and the problem persists,
connector. beakers and reset if tripped. Contact your local Lincoln
2. Faulty control cable. Repair or Authorized Field Service Facility.
replace cable.
3. Faulty wire feeder. Replace wire
feeder.

No auxiliary power. 1. Open circuit breakers. Reset


breakers. If breakers keep trip-
ping, reduce power draw.
2. Faulty connections to auxiliary
receptacles. Check connections.
3. GFCI Receptacle may have
tripped. Follow GFCI Receptacle
Testing and Resetting Procedure
in the MAINTENANCE section of
this manual.
4. Faulty PC board or welder alterna-
tor.

CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D
E-6 TROUBLESHOOTING E-6
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS POSSIBLE RECOMMENDED
(SYMPTOMS) CAUSE COURSE OF ACTION
The welding arc is cold. The weld- 1. Make sure the MODE selector
ing arc is not stable or is not satis- switch is in the correct position for
factory. the engine runs normally. the process being used. (For exam-
The auxiliary power is normal. ple, CV-WIRE, PIPE, CC-STICK.)
2. Make sure the electrode (wire, gas,
voltage, current etc.) is correct for
the process being used.
3. Check for loose or faulty connec-
tions at the weld output terminals
and welding cable connections.
4. The welding cables may be too long
or coiled, causing an excessive
voltage drop. If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.

CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D
F-1 DIAGRAMS F-1

RANGER 305D
F-2 DIAGRAMS F-2

RANGER 305D
F-3 DIAGRAMS F-3

RANGER 305D
F-4 DIAGRAMS F-4

RANGER 305D
F-5 DIAGRAMS F-5

RANGER 305D
F-6

ENGINE W ELDERS LN-8


/ CONNECTION DIAGRAM

WARNING
ELECTRIC SHOCK can kill MOVING PARTS can injure
Do not operate with panels open. Keep guards in place.
Disconnect NEGATIVE (-) Battery lead Keep away from moving parts.
before servicing. Only qualified personnel should install,use
Do not touch electrically live parts. or service this equipment.

14 PI
N
AMPHENOL TO NL-8NPUT
I
CABLE PLUG

K595CONTROL CABLE

+ _
TO W ORK

RANGER 305D
ELECTRODE CABLE
DIAGRAMS

TO WIRE F
EED UNIT

CAUTION

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WIL
AN INCREASE IN THE AC WIRE FEEDER VOLTAGE, WHICH CAN DAMAGE THE CONTROL CIRCUIT. THE ENGINE GOVERNOR SETTING IS
AT THE FACTORY DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE
APPLICATIONS. SEE OPERATING MANUAL.
N.B. CONNECT WELDING CABLES TO OUTPUT STUDS FOR DESIRED POLARITY. POSITION THE WIRE FEEDER VOLTMETER SWITCH TO
MATCH THE POLARITY OF THE ELECTRODE CABLE.
N.C. PLACE IDLER SWITCH IN HIGH POSITION.

4-14-2000

S24787-6
F-6
F-7 DIAGRAMS F-7

RANGER 305D
F-8 DIAGRAMS F-8

RANGER 305D
F-9 DIAGRAMS F-9

9/03
2

RANGER 305D
F-10 DIAGRAMS F-10

RANGER 305D
F-11

RANGER 305D
DIAGRAMS
ENHANCED
WIRING DIAGRAM

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside
the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
F-11
FOR CODES 11188, 11275
F-12

RANGER 305D
DIAGRAMS
ENHANCED
WIRING DIAGRAM

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside
the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
F-12
11.0 3
F-13

280. 2
1326.4
29.5 7 6. 33
751. 0 160. 9

26.64
676.7

29 .0 0 35. 77
736. 6 34. 24 908 .4
869 .8
CENTER OF GRAVIT Y
29.8 3
CIRCUIT 757. 6
BREAKERS

11.3 0
287. 0

52.0 0

RANGER 305D
1320 .8
51.2 0 21.5 0
1300 .5 546. 1
DIMENSION PRINT

17.5 0 21.0 6
444. 5 534. 9
19.50
495.3

CS MAY NOT
NOTE: CASE FRONTGRAPHI MATCH ALL CODES.
B
F-13

M20334
NOTES

RANGER 305D
Do not touch electrically live parts or Keep flammable materials away. Wear eye, ear and body protection.

WARNING electrode with skin or wet clothing.


Insulate yourself from work and
ground.
Spanish
No toque las partes o los electrodos Mantenga el material combustible Protjase los ojos, los odos y el
AVISO DE bajo carga con la piel o ropa moja-
da.
fuera del rea de trabajo. cuerpo.

PRECAUCION Aislese del trabajo y de la tierra.

French Ne laissez ni la peau ni des vte- Gardez lcart de tout matriel Protgez vos yeux, vos oreilles et
ments mouills entrer en contact inflammable. votre corps.
ATTENTION avec des pices sous tension.
Isolez-vous du travail et de la terre.

German Berhren Sie keine stromfhrenden Entfernen Sie brennbarres Material! Tragen Sie Augen-, Ohren- und Kr-
Teile oder Elektroden mit Ihrem perschutz!
WARNUNG Krper oder feuchter Kleidung!
Isolieren Sie sich von den
Elektroden und dem Erdboden!
Portuguese
No toque partes eltricas e elec- Mantenha inflamveis bem guarda- Use proteo para a vista, ouvido e
trodos com a pele ou roupa molha- dos. corpo.
ATENO da.
Isole-se da pea e terra.

Japanese

Chinese

Korean

Arabic

READ AND UNDERSTAND THE MANUFACTURERS INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE
USED AND FOLLOW YOUR EMPLOYERS SAFETY PRACTICES.

SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS
CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.

LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A
ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.

LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-
STELLERS. DIE UNFALLVERHTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.
Keep your head out of fumes. Turn power off before servicing. Do not operate with panel open or
Use ventilation or exhaust to
remove fumes from breathing zone.
guards off.
WARNING
Los humos fuera de la zona de res- Spanish
Desconectar el cable de ali- No operar con panel abierto o
piracin.
Mantenga la cabeza fuera de los
mentacin de poder de la mquina
antes de iniciar cualquier servicio.
guardas quitadas. AVISO DE
humos. Utilice ventilacin o
aspiracin para gases.
PRECAUCION
Gardez la tte lcart des fumes. Dbranchez le courant avant lentre- Noprez pas avec les panneaux French
Utilisez un ventilateur ou un aspira- tien. ouverts ou avec les dispositifs de
teur pour ter les fumes des zones
de travail.
protection enlevs. ATTENTION
Vermeiden Sie das Einatmen von Strom vor Wartungsarbeiten Anlage nie ohne Schutzgehuse German
Schweibrauch! abschalten! (Netzstrom vllig ff- oder Innenschutzverkleidung in
Sorgen Sie fr gute Be- und
Entlftung des Arbeitsplatzes!
nen; Maschine anhalten!) Betrieb setzen! WARNUNG
Portuguese
Mantenha seu rosto da fumaa. No opere com as tampas removidas. Mantenha-se afastado das partes
Use ventilao e exhausto para Desligue a corrente antes de fazer moventes.
remover fumo da zona respiratria. servio. No opere com os paineis abertos ATENO
No toque as partes eltricas nuas. ou guardas removidas.

Japanese

Chinese

Korean

Arabic

LEIA E COMPREENDA AS INSTRUES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS
PRTICAS DE SEGURANA DO EMPREGADOR.
World's Leader in Welding and Cutting Products
Sales and Service through Subsidiaries and Distributors Worldwide
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com