PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Corbel Design

INPUT DATA
CONCRETE STRENGTH fc' = 5 ksi

REBAR YIELD STRESS fy = 60 ksi
FACTORED SHEAR LOAD Vu = 100 k
FACTORED TENSILE LOAD Nuc = 40 k
WIDTH b = 15 in
EFFECTIVE DEPTH d = 20 in
OVERALL DEPTH h = 22 in
SHEAR SPAN a = 4 in
PRIMARY REINFORCEMENT 3 # 7
CLOSED STIRRUPS 3 # 3 ( spacing 4 in o.c. )

ANALYSIS
CHECK DIMENSIONAL REQUIREMENTS (ACI Sec. 11.9.1 & 11.9.2)
a/d = 0.20 < 1 [SATISFACTORY]
Nuc / Vu = 0.40 < 1 [SATISFACTORY]
hc = 12.00 > 0.5 d [SATISFACTORY]

CHECK SECTION (ACI Sec. 11.9.3.2)

MIN (0.2 f cbd , 0.8 bd )


'
Vu < = 204 k [SATISFACTORY]

CHECK REINFORCEMENT

N uc 0.2V u Vu
= 0.784 in2 Avf = 1.401 in2
An MAX , uf y
f y f y (ACI Sec. 11.9.3.4) (ACI Sec. 11.7.4)

Mu
0.85bd f 'c 1 1
0.383b d
2 '
f

M u V ua N uc h d
c
Af = 0.449 in2 = 480 in-k
fy
(ACI Sec. 10.2)

2 Avf 0.04 f 'c


As MAX
A f An , An , bd = 1.718 in2 < A s , provd 1.800 in2
3 f
y
(ACI Sec. 11.9.3.5) [SATISFACTORY]

A s An
Ah = 0.467 in2 <
Ah , provd 0.660 in2
2
(ACI Sec. 11.9.4) [SATISFACTORY]