Beruflich Dokumente
Kultur Dokumente
The project aims to estimate and confront the values of primary, secondary and total
settlement. The values were obtained by the application of equations and the
utilization of parameters of compressibility of different samples, which were extracted
from a place located in the west zone of Rio de Janeiro. In the estimation of the
settlement, the embankment was considered of being at 3 meters, the water was
located in the ground level, and the effect of the embankments submergence was
also contemplated. The samples are in different levels of perturbation, and they are
divided in: undisturbed, disturbed, and corrected. The densification test was realized
in all samples in order to obtain the necessarily parameters to preview the settlement.
The undisturbed tests were made by the COPPEs Geotechnical Laboratory UFRJ,
while the tests in the disturbed samples were made in the UNIPAMPAs Geotechnical
and Paving Laboratory. It was utilized the Lunne et. al. (2002) and Coutinho (2007)
methods to classify the analyzed samples. The method to correct the quality of the
samples proposed by Coutinho (2007) was applied in this project. This method
utilizes logarithmic graphics to correct the pre-consolidation tensions and the
recompression coefficient of the samples. From the total settlements analyzes, it was
possible to affirm that the quality directly influences in the settlements prevision, and
that the larger the deformation of the samples, the greater the estimated settlement
magnitude.
Key words: Classification of the samples quality, correction of the samples quality,
settlements prevision.
LISTA DE SIMBOLOS / ABREVIATURA / SIGLAS
3. MATERIAIS E MTODOS..................................................................................... 45
3.1.1 Solo............................................................................................................ 45
REFERNCIAS...................................................................................................... 72
16
1. INTRODUO
1.3 Objetivos
1.4 Justificativa
2. REVISO BIBLIOGRFICA
2.1Solos Moles
N Argilas Moles
1. O volume de vazios pode atingir 98% do volume total.
2. Contraem-se ao secar.
3. Apresentam coeso marcante, dependendo da umidade.
4. So materiais plsticos.
5. Comprimem-se lentamente, sob a aplicao de cargas superficiais.
6. So muito Compressveis.
7. M permeabilidade a praticamente impermeveis.
Para o presente estudo esse o principal ensaio, dado que a partir dele
possvel se extrair os parmetros necessrios para a classificao e correo da
qualidade de amostra.
Os parmetros obtidos com o ensaio so: Tenso de pr-adensamento,
definida como a tenso correspondente ao maior carregamento que um solo esteve
submetido na sua vida geolgica; presso efetiva inicial, definida como sendo a
presso vertical total que se desenvolve no esqueleto granular dos solos pelo
contato gro-a-gro; razo de pr-adensamento, expresso do histrico de tenses
do solo; ndice de vazios inicial; ndice de compresso e ndice de recompresso.
Tais parmetros so fundamentais no calculo de recalques primrios e secundrios,
sendo tambm informaes imprescindveis para obras executadas sobre solos
moles. Tais parmetros podem ser observados na curva caracterstica do ensaio
exposto na Figura 2.
24
Aps realizao dos ensaios, deve-se calcular a altura dos slidos do corpo
de prova pela Equao 1:
Razo de Pr - e/e0
Adensamento Excelente a Boa a
Ruim Muito Ruim
(OCR) Muito Bom Aceitvel
1-2 <0,04 0,04 0,07 0,07 0,14 >0,14
2-4 <0,03 0,03 0,05 0,05 0,1 >0,1
Onde e = e0 e(v0); e0 ndice de vazios da amostra; e(v0) ndice de vazios para v0.
Fonte: Adaptada de Baroni (2010)
A partir do proposto por Lunne et. al. (1997) e Coutinho et. al. (1998),
Coutinho (2007) apresenta a proposta que leva em considerao a relao da
variao no volume de vazios com o ndice de vazios inicial, e/e0.
Coutinho (2007), analisando os critrios adotados por Lunne et al. (1997),
conclui que para as argilas do Recife a proposta de Lunne et al. (1997), deveras
33
Excelente a Boa a
Ruim Muito Ruim
Muito Bom Aceitvel
e/e0 <0,05 0,05 0,08 0,08 0,14 >0,14
Fonte: Adaptada de Baroni (2010)
ressalta que este tipo de correo til para a correo aproximada do valor de vm
de amostras em projetos prticos.
Figura 8 Curva CR X v0
Onde: IDo a relao da tenso vertical efetiva de campo ( v0) com a tenso de
escoamento (vy).
Baseado nesses critrios as amostras podem ser corrigidas para obter-se um
novo valor da tenso de escoamento (vy). Na equao 6, os parmetros e0, IDo e
C ` Cc ` (hat rn ). at rn . sub
rn1 H o . s . log vm . log vo
1 evo `vo 1 evo `vm
Cc ndice de compresso
3. MATERIAIS E MTODOS
3.1 Materiais
3.1.1 Solo
O solo que foi utilizado na pesquisa foi coletado em depsito de argila mole
localizado em Itanhagu, bairro da Barra da Tijuca, zona Oeste da cidade do Rio de
Janeiro, RJ. As amostras foram retiradas pelos laboratoristas e tcnicos da UFRJ,
seguindo as especificaes detalhadas em Aguiar (2008) e Baroni (2010).
Os ensaios de adensamento oedomtrico em amostras de solo indeformado,
foram realizados no laboratrio de Geotecnia da COPPE UFRJ. Os ensaios
realizados nas amostras de solo amolgado foram realizados no laboratrio de
Geotecnia e Pavimentao da Universidade Federal do Pampa UNIPAMPA.
Na Figura 10 (a), encontra-se a amostra em grau inicial de amolgamento,
onde ela apresenta textura argilosa.
Com o armazenamento da amostra tanto no Laboratrio de Geotecnia da
COPPE, quanto no Laboratrio de Geotecnia e Pavimentao da UNIPAMPA, houve
uma leve perda de umidade natural do solo. Para que as amostras voltassem
umidade natural, foi inicialmente retirada uma parcela da amostra para determinar a
umidade antes do ensaio, e depois adicionada gua para regularizao da umidade
das amostras.
A Figura 10 (b) a representao da amostra com textura pastosa aps
regularizao da umidade onde a amostra foi misturada com o auxilio de uma
esptula para maior desestruturao da amostra.
46
(a) (b)
Fonte: Autoria Prpria
3.2 Mtodos
.
A tenso de Pr-Adensamento, bem como os valores de Cc e Cs foram
obtidos a partir do mtodo proposto por Pacheco e Silva, que demonstrado no tem
2.3.1.2.4.2.2 desse trabalho.
49
(a)
(b)
51
(c)
Fonte: Elaborao Prpria
4. DISCUSSES E RESULTADOS
4,00
3,50
ndice de Vazios
3,00
2,50
2,00
1,50
1,00
Fonte: COPPE UFRJ.
53
5,50
5,00
4,50
ndice de Vazios
4,00
3,50
3,00
2,50
2,00
1,50
Fonte: COPPE UFRJ.
5,00
4,50
4,00
ndice de Vazios
3,50
3,00
2,50
2,00
1,50
1,00
Fonte: COPPE UFRJ.
54
3,50
3,00
2,50
2,00
1,50
1,00
0,50
0,00
Fonte: COPPE UFRJ.
5,00
4,50
4,00
3,50
ndice de Vazios
3,00
2,50
2,00
1,50
1,00
0,50
0,00
Fonte: COPPE UFRJ
55
4,00
3,50
3,00
ndice de Vazios
2,50
2,00
1,50
1,00
0,50
0,00
Fonte: COPPE UFRJ.
4
ndice de Vazios
0
1 10 100 1000
Tenso Vertical (kPa)
8,00
7,00
6,00
ndice de Vazios
5,00
4,00
3,00
2,00
1,00
0,00
1 10 100 1000
Tenso Vertical (kPa)
7,00
6,00
5,00
ndice de Vazios
4,00
3,00
2,00
1,00
0,00
1 10 100 1000
Tenso Vertical (kPa)
7,00
6,00
5,00
ndice de Vazios
4,00
3,00
2,00
1,00
0,00
1 10 100 1000
Tenso Vertical (kPa)
A classificao das amostras foi feita obedecendo aos critrios propostos por
Lunne et al (1997) e Coutinho (2007), expostos nas Tabelas 2 e 3 desse trabalho. A
Tabela 5 exibe as classificaes das amostras indeformadas e amolgadas.
A partir da Tabela 5, possvel verificar que mesmo em amostras antes
dadas como de boa qualidade (indeformadas) a classificao de Lunne et al (1997)
e Coutinho (2007) comprovam a grande dificuldade de manipulao dessas
amostras. Contudo apenas para as amostras que se encontram mais prximas da
superfcie foi possvel a classificao como amostras de boa qualidade.
59
Amostra Profundidade (m) 'vm (kPa) 'v0 (kPa) OCR e0 e ('v0) De/e0 Lune et al. (1997) Coutinho (2007)
2,25 - 2,75 12,00 7,11 1,69 4,04 3,75 0,07 Ruim Boa a Aceitvel
2,75 - 3,25 10,00 6,27 1,59 5,77 5,55 0,04 Excelente a Muito Bom Excelente a Muito Bom
4,25 - 4,75 8,00 9,23 0,87 5,20 4,60 0,12 Ruim Ruim
Indeformada
5,25 - 5,75 90,00 10,86 8,29 5,57 5,20 0,07 Ruim Ruim
8,75 - 9,25 16,00 19,32 0,83 5,02 4,40 0,12 Ruim Ruim
11,25 - 11,75 21,00 26,10 0,80 4,11 3,52 0,14 Muito Ruim Muito Ruim
2,75 - 3,25 6,50 6,27 1,04 5,43 4,90 0,10 Ruim Ruim
5,25 - 5,75 3,00 10,86 0,28 8,06 6,20 0,23 Muito Ruim Muito Ruim
Amolgada
8,75 - 9,25 7,00 19,32 0,36 6,79 5,50 0,19 Muito Ruim Muito Ruim
11,25 - 11,75 12,50 26,10 0,48 7,16 5,40 0,25 Muito Ruim Muito Ruim
Onde: vm = Tenso de Pr-Adensamento; v0 = Tenso Efetiva Inicial; OCR = Razo de Pr-Adensamento; e0 = ndice de Vazios Inicial da
Amostra; e(v0) = ndice de Vazios para a Tenso Efetiva do Solo; e = (e0- e(v0)).
Fonte: Elaborao Prpria.
60
100,00
90,00
80,00
70,00
50,00
40,00
30,00
20,00
10,00
0,00
0,00 5,00 10,00 15,00 20,00 25,00
Ev0 (%)
30,00
y = -3,916ln(x) + 29,626
25,00
20,00
CR (%)
15,00
10,00
5,00
0,00
0,00 5,00 10,00 15,00 20,00 25,00
Ev0 (%)
Amostra Profundidade (m) 'vm (kPa) 'vm (kPa) (Corrigida) Ev0 (%) CR (%) CR (%) (Corrigido)
2,75 - 3,25 6,50 24,67 8,20 12,10 21,39
5,25 - 5,75 3,00 9,19 20,53 12,04 17,79
Amolgada
8,75 - 9,25 7,00 12,76 16,61 16,92 18,62
11,25 - 11,75 12,50 8,33 21,61 22,28 17,59
Legenda: Evo = Deformao Volumtrica Inicial da Amostra; CR = Razo de Compresso.
Fonte: Elaborao Prpria.
Calculo do recalque
secundrio para as
camadas 1, 2, 3 e 4 (m)
1 0,167
2 0,116
3 0,137
4 0,111
Total 0,530
Calculo do recalque
secundrio para as
camadas 1, 2, 3 e 4 (m)
1 0,086
2 0,050
3 0,077
4 0,067
Total 0,280
Calculo do recalque
secundrio para as
camadas 1, 2, 3 e 4 (m)
1 0,152
2 0,074
3 0,085
4 0,053
Total 0,364
do aterro para amostras corrigidas 15% menor do que para amostras amolgadas.
Quando comparada com as amostras indeformadas a altura final do aterro fica 5%
maior, o que comprava a eficincia do mtodo proposto por Coutinho (2007). Sendo
assim os valores de recalque primrio, recalque secundrio, recalque total e altura
total do aterro so respectivamente 1,89m, 0,36m, 2,25m e 5,25m.
Analisando os valores obtidos de recalques totais para as amostras
indeformadas, amolgadas e corrigidas possvel afirmar que o mtodo de correo
dos parmetros da curva de adensamento proposto por Coutinho (2007) valido
para a argila mole estudada no presente estudo. Essa afirmativa possvel j que o
valor de recalque encontrado aps a correo se torna intermedirio aos valores das
amostras indeformadas e amolgadas, tendendo a ficar mais prximo da amostra
indeformada.
Atravs dos resultados obtidos possvel reafirmar a importncia de amostras
de boa qualidade para a execuo de projetos confiveis. Quando no for possvel a
obteno dessas amostras devido dificuldade encontrada, principalmente se
tratando de solos moles compressveis, a adoo de um mtodo de correo da
qualidade de amostras eficaz na minimizao dos erros de projeto. A adoo de
mais de um mtodo de correo pode elevar o nvel de confiabilidade do projeto,
pois possvel confrontar os valores encontrados.
REFERNCIAS
______. NBR 6508: Gros de Solo que Passam na Peneira 4,2mm Determinao
da Massa Especfica. Associao Brasileira de Normas Tcnicas, Rio de Janeiro,
RJ, 1984.
73