Expanding Gate Valve

M&J Valve was founded in 1962 by Marvin

Grove and has been a leader in the pipeline


For A Dependable Shutoff Count On
valve industry since its inception. Now The Sealing Reliability of the M&J
part of SPX Flow Technology, M&J Valve
Model EG Expanding Gate Valve
meets or exceeds the quality standards of

our customers and the valve industry. M&J The M&J Model EG valves are full bore through conduit valves with rising

Valve product offering includes slab and stem and parallel expanding gate and segment for tight mechanical seal
and positive shut-off, both upstream and downstream, and under both low
expanding through-conduit gate valves,
and high differential pressure. The Model EG valve provides a superior bi-
axial surge valves and rotary control valves,
directional mechanical seal because the two-piece gate assembly expands
piston, ball, and swing check valves. M&J
against the seating areas in the open or closed position. The greater the
Valve can provide a wide variety of flow
torque, the tighter the seal. The end result is an extremely heat resistant seal
control solutions for liquid and gas markets. that is unaffected by line pressure or vibration.
This combination of products, technical
This design has proven performance in critical applications all over the world,
know-how and field experience has allowed
such as isolation valves in power plants, ESD valves in production, block
for a history of product innovation which valves in process systems, high temperature valves in refineries, and pipeline
has positioned M&J Valve in a leadership valves in critical areas. The M&J Model EG is constructed for increased
position within the valve industry. reliability and ease of maintenance and operation. These valves are readily
available in all the sizes, pressure ranges, and trims used in piping systems
requiring the positive shut off of liquid or gas.

Finding innovative ways to help the world


G e n e r a l S p e c i f i cat i o n s
meet its ever growing demand for energy Sizes: 2 and larger in all ANSI classes
is a key focus for SPX. As a multi industry Temperature range: -50 F to +1000 F
manufacturer, we provide creative solutions Flanged end connections/ Weld End Connections

that serve global energy markets in a Fire tested to API-6FA


ISO 9001
myriad of ways. SPX is helping to meet
Available: NACE, high corrosive, high and low
that demand with a broad range of high
temperature
quality, custom-engineered systems and
Geothermal trims
components that can also help improve

efficiency and reduce the use of natural F e at u r e s


resources. We also supply a wide range Increased throughput full bore unrestricted flow
of components from air preheaters Tight seal in all flow conditions; bi-directional mechanical sealing

to filter systems. SPX off-the-shelf and Can replace two valves; double block and bleed capability
Long, leak free service life; protected seat design
customized solutions are supporting all
Easy to operate; low operating torque; single piece stem; visual indication
phases of oil, gas and biofuel production,
of position
from exploration, extraction and processing
Easy to maintain; stem packing does not require lubrication; backup
to transport and storage.
sealing options; emergency sealing through the stem and seat; can be
overhauled in-line; top entry access to all internals

2
Option s
Wide range of trims Typical product applications
Can be manual, electric, or hydraulic actuators
Stem and sealant injection extensions for buried service
Locking devices
Wide range of testing and verification procedures The M&J Model EG valves are used in a wide range of

Zero emission secondary stem seals critical applications, from pipelines to power plants, in ESD
and other demanding isolation applications.

Oil, Gas, Liquid Products &


One-piece Secondary Recovery
stem design
with an Mainline Block Valves
F l a n g e d t o p y o ke integrally
tube for easy forged stem
Tank and Station Valves
adaptability for head
any mode of
operation Block & Bleed Valves

Manifold Valves
Stem seal design
w i t h ch e v r o n r i n g s Launcher/Receiver Trap Valves
to ensure sealing
integrity Meter Bypass Valves

Emergency Shutdown Valves

Expanding gate Hot Tap Valves


to provide a
t i g h t m e ch a n i c a l
seat seal Pr o t e c t e d
upstream & seat faces
downstream, to extend
under low & valve life
high differential
pressures

Heavier valve
body casting Fu l l b o r e
than comparable through
valves in its conduit design
class to minimize
pressure drop
& turbulence
M & J E G E x pa n d i n g G at e Va lv e s a r e ava i l a b l e
i n 2 a n d l a r g e r i n a l l AN S I C l a ss e s .

3
P r i n c i p l e o f O p e r at i o n
Valve Operation

The valves parallel expanding gate and segment provides a tight mechanical
seat seal upstream and downstream and under low and high differential
pressure conditions.

1.) Traveling to the final open position the lower back angles are in contact
Ope n Pos ition
with each other. With further upward movement of the gate with the
segment stopped, the centralizer mechanism allows the gate-segment
assembly to expand, sealing against both seats, protecting the seat faces
The Expanding Gate Valve achieves its sealability
from line flow, while isolating the body cavity from the flow bore.
by mechanically expanding the gate and segment
assembly against the seats. The valve must be
torqued fully open or fully closed to seal properly.
Do NOT back off on the handwheel; leave it
tight in both the open and closed positions.
This method of operation prevents damage to
the sealing surfaces of the gate and seat and
isolates the body cavity preventing buildup of
foreign material, increasing the life of the valve.

2.) During open and closing travel, the gate-segment assembly is collapsed
with both back angle surfaces in contact. The centralizer mechanism
prevents relative movement between the gate and segment allowing the gate
and segment assembly to travel freely without sticking or wedging.

3.) Traveling to the final closed position, the upper back angles of the gate
and segment move into contact with each other. With further downward
movement of the segment stopped, the centralizer mechanism allows the
C lo s e d P o s i t i o n
gate-segment assembly to expand, sealing against both seats, forming a
tight mechanical seal.

4
Em e r g e n cy S e at S e a l S t e m F e at u r e s
The M&J Expanding Gate Valve requires no lubrication. If foreign The M&J Expanding Gate Valve is a one-piece stem design which
matter causes damage to the seat seal during operation, all valves has an integrally forged stem head.
are fitted with an emergency sealant injection provision (Fig. 1).
S t e m S e a l i n g F e at u r e s
Sealant can be injected directly to the seat sealing area to effect
The stem seal design (Fig. 2) utilizes Chevron rings to insure sealing
an emergency seal. If valves are to be buried, or in an inaccessible
integrity. The packing box seal configuration is an open/closed
location, these fittings can be extended per the customers
design to allow emergency bulk packing injection in the event of a
requirements.
S ealant
stem leak. Alternate seal designs are available to meet a wide variety
Fitti ng of customers requirements.
Ste m

B o n n e t / yo k e
B o dy
To p A da p t e r

P r e ss u r e R i n gs
S e a l a n t Pa ss ag e
Lante r n R i ng

G at e

S e at X- r i n g
I n s e rt
P r e ss u r e R i n gs

B ot to m
A da p t e r
S e at

Fig. 1
Fig. 2

P r e ss u r e R e l i e f
The M&J Expanding Gate Valve design
will trap pressure in the valve body
cavity when the valve is in the full
open or closed position. High internal
pressures can result from thermal
expansion. To protect the valve from
overpressure, the valve is provided with
upstream relief piping which relieves
excess body pressure to the upstream
side of the valve (Fig. 3B). As an Ch e c k Va lv e
alternate, a relief valve can be provided
(Fig. 3A).

N e e d le
Va lv e s
R e li e f
Va lv e

Fig. 3a Fig. 3b

5
R e c o mm e n d e d S pa r e Pa r t s
It is recommended that the following spare parts be inventoried in
operations having numerous valves of a given size and an in-house
maintenance program:

N u m b e r o f Va l v e s t o b e S u p p o r t e d
Pa r t D e s c r i p t i o n
<10 11-20 21-30 31-40

Gate & Segment Assembly 0 1 2 3

Seat Assembly 0 2 4 6

Stem 0 1 2 3

B o n n e t & Yo k e S e a l s 1 2 3 4

P a ck i n g S e t 1 2 4 6

G e a r B ox 0 0 1 1

Handwheel 0 1 2 2

Ve n t / G r e a s e F i t t i n g 2 4 8 12

I n j e c t i b l e P a ck i n g ( b ox ) 1 2 4 4

B o d y R e l i e f Va l v e 1 2 4 6

P a ck i n g I n j e c t i o n F i t t i n g 1 2 4 6

Stem Nut Bearings, Set 1 2 2 4

2 - 4 6 an d Larg e r
S e rvice
SPX is committed to helping you maximize the performance
of your valve solutions throughout their lifetime. SPX provides N a m e p l at e Data

innovative ways to improve your productivity and profitability. Well Nameplates on M&J Expanding Gate Valves provide all of the

help you minimize your asset investments. While ensuring that you necessary information to identify the valve when contacting the

continue to meet your production requirements. Our well trained and factory for spares or assistance.

experienced staff is available to provide technical advice, backup


documentation, spare parts and repair services; in the plant or in
the field. We will work with you, from start to finish, to ensure the
product you need is the product you get.

Please consult your local M&J representative to take advantage of


our team of experts, ready to assist you with your every requirement.

API 6 A NON - RI S IN G S TE M EXPANDIN G G ATE


F i r e T e s t Q ua l i f i cat i o n s VALV E S
M&J Expanding Gate Valves have been designed to meet the most M&J also manufactures Model EG Non-Rising Stem Expanding
stringent standards. Part of this is fire testing to the requirements Gate Valves. These valves are manufactured and tested in
of API-6FA. In addition to the normal in-house testing program, fire accordance with API 6A and are available in 2000 and 3000 psi
tests have been witnessed and certified by independent authorities. working pressures.
Fire test qualified design and certification can be provided, when
specified.

6
Standard Product And Available Options
S ta n da r d
Featu r e Wh e n S p e c i fi e d
( IN / M M)

API - 6 D / Q 1 X

I SO 9001 X

2-12
H a n d wh e e l O p e r ato r
(50.8-304.8)

1 4 & LG R 4-12
B e v e l G e a r O p e r ato r
(355.6 & up) (101.6-304.8)

P ow e r Act uato r X

D o u b l e B lo c k & B l e e d X

H i d d e n S e c o n da ry S e a l a n t Ch e c k X

E xt e n d e d S t e m X
B u r i e d S e rvice
E xt e n d e d S e a l a n t, V e n t & D r a i n X

Lo c k i n g D e v i c e X

Tran s ition Pi ece (Pu ps) X

Em e r g e n cy Pac k i n g I n j e ct i o n X

E xt e r n a l R e l i e f X

E xt e r n a l P i p i n g to U p s t r e a m X

B o dy V e n t F i t t i n g X

B o dy D r a i n / I n j e ct i o n F i t t i n g X

6 - 1 2 ( 1 5 2 . 4 - 3 0 4 . 6 mm ) X
L i f t L u gs
1 4 & u p ( 1 0 1 . 6 mm & u p ) X

B o dy F o ot i n g X

S t e m P o s i t i o n I n d i cato r X

O u t s i d e Pac k i n g G l a n d X

API M o n o g r a m X

Hyd ro-S h e ll X

H y d r o - S e at X

API - 6 D T e s t : A i r S e at X

O p e r at i o n a l To r q u e T e s t X

E xt e n d e d H y d r o T e s t X

V i s ua l ( API 6 D ) X

U lt r a s o n i c X

NDE : Dy e P e n e t r a n t X

M ag n e t i c Pa r t i c l e X

Rad iog raphy X

H y d r ot e s t R e p o r t s X

M at e r i a l T e s t R e p o r t s ( M TRs ) X

H y d r ot e s t Ch a r t s X

X
NDE R e p o r t s
D o c u m e n tat i o n / C e r t i f i cat i o n :
NACE X

F i r e - T e s t C e r t i f i cat i o n X

C e r t i f i cat e o f C o m p l i a n c e X

O p e r at i o n a l T e s t R e p o r t s X

7
Exploded View

8
S t a n d a r d M e t a l l i c Tr i m s Fo r
Ite m D e scr i ption
Selected Services
A1 Body/ Bonnet Studs
A2 Body/ Bonnet Nuts T1 - Standard - Carbon Steel - Hydrocarbons

A3 Yo k e Tu b e / B o n n e t S t u d s
T3 - Full Stainless Steel - Highly Corrosive
A4 Yo k e Tu b e / B o n n e t N u t s
B1 Body T 4 - C a r b o n S t e e l - N AC E
B2 Bonnet
B3 Yo k e Tu b e T 6 - C a r b o n S t e e l - 4 1 0 S S I n t e r n a l s - N AC E

F1 P a ck i n g F i t t i n g
T 7 - B r i n e - S a l t - M i l d l y C o r r o s i v e - N AC E
F2 P a ck i n g P l u g / Ve n t
F3 B o d y Ve n t / G r e a s e F i t t i n g T 8 - Wa t e r f l o o d - B r i n e - N AC E
O1 Operator
O2 Yo k e / O p e r a t o r C a p S c r e w S 4 - C a r b o n S t e e l - N AC E - 1 7 - P H S t e m

O3 Stem Protector
G 1 - H i g h Te m p e r a t u r e - G e o t h e r m a l
O4 Stem Protector Cap
O5 Indicator Rod G 2 - H i g h Te m p e r a t u r e - G e o t h e r m a l - H F G a t e
O6 R o d Wi p e r
O7 Lower Bearing L 1 - L o w Te m p e r a t u r e - C a r b o n S t e e l

O8 Stem Nut
L 4 - L o w Te m p e r a t u r e - N AC E C a r b o n S t e e l
O9 Upper Bearing
O10 Bearing Cap
Note: This is a sample of services and standard trims.
O11 Grease Fitting
For assistance with a specific service, contact M&J Valve.
O12 Oil Seal
O13 Handwheel
S1 Body/ Bonnet Seal
S2 Sediment Seal
S3 Yo k e Tu b e G a s k e t
S4 P a ck i n g S e t
S5 Latern Ring
T1 Gate & Segment
T2 Stem
T3 Seat Assembly
T4 Gate Skirt
T5 Segment Skirt
U1 Upstream Relief

Seal Code Definitions

D e scr i ption RV GT LR GV
Ite m
T e m p e r at u r e R a n g e 0F to 350F 0F to 550F 0F to 350F 0F to 550F

S1 Body/ Bonnet Seal 1 8 - 8 S ST/ G r a f o i l 1 8 - 8 S ST/ G r a f o i l 1 8 - 8 S ST/ G r a f o i l 1 8 - 8 S ST/ G r a f o i l

S2 Sediment Seal Vi t o n EPDM Vi t o n Vi t o n

S3 Yo k e Tu b e G a s k e t 1 8 - 8 S ST/ G r a f o i l 1 8 - 8 S ST/ G r a f o i l 1 8 - 8 S ST/ G r a f o i l 1 8 - 8 S ST/ G r a f o i l

S4 P a ck i n g S e t Ryton Filled TFE 40% Glass Filled TFE R y t o n / Vi t o n Graphoil

S5 Lantern Ring Not Reqd. Not Reqd. AISI 1018/ E N P AISI 1018/ E N P

9
F i g u r e N u m b e r Ke y

TRI M CODE DEFINITION S

Ite m D e scr i ption T1 L1 T3 T4 L4 T6 T7 T8 S4 G1 G2

AST M A 2 1 6 AST M A 2 1 6
AST M A 2 1 6 AST M A 3 5 0 AST M A 3 5 1 AST M A 2 1 6 AST M A 3 5 0 AST M A 2 1 6 WC C / WC C / AST M A 2 1 6 AST M A 2 1 6 AST M A 2 1 6
B1 Body
WC C LC C CF8M WC C LC C WC C E P OXY E P OXY WC C WC C WC C
C OAT E D C OAT E D

AST M A 5 1 6 AST M A 5 1 6
AST M A 5 1 6 AST M A 5 3 7 AST M A 5 1 6 AST M A 5 3 7 AST M A 5 1 6 G R. 70/ G R. 70/ AST M A 5 1 6 AST M A 5 1 6 AST M A 5 1 6
B2 Bonnet AISI 316SS
G R. 70 CL1 G R. 70 CL1 G R. 70 E P OXY E P OXY G R. 70 G R. 70 G R. 70
C OAT E D C OAT E D

AST M A 5 1 6 /
AST M A 5 1 6 / AST M A 5 3 7 A 3 6 /A 5 3 AST M A 5 1 6 / AST M A 5 3 7 AST M A 5 1 6 / AST M A 5 1 6 / AST M A 5 1 6 / AST M A 5 1 6 / AST M A 5 1 6 / AST M A 5 1 6 /
B3 Yo k e Tu b e
A 3 6 /A 5 3 C L 1 /A 3 3 3 625 CLAD A 3 6 /A 5 3 C L 1 /A 3 3 3 A 3 6 /A 5 3 A 3 6 /A 5 3 A 3 6 /A 5 3 A 3 6 /A 5 3 A 3 6 /A 5 3 A 3 6 /A 5 3
P KG B OX

AST M
AST M A 2 1 6 AST M A 2 1 6 AST M A 2 1 6 AST M A 2 1 6 AST M A 2 1 6 AST M A 2 1 6 AST M A 2 1 6 AST M A 2 1 6
AST M A 3 5 1 AST M A 4 8 7 A747 G R
T1 G a t e & S e g m e n t G R . WC C / G R . WC C / G R . WC C / G R . WC C / G R WC C / G R WC C / G R WC C / G R WC C /
CF8M G R CA 6 N M CB7CU-1
ENP ENP ENP ENP ENP ENP ENP HF
(17-4PH)

AST M B 6 3 0 AST M B 6 3 0 AST M B 6 3 0 AST M B 6 3 0 AST M B 6 3 0


AISI 4140/ AISI 4140/ AISI 4140/ AISI 4140/ AISI 4140/
T2 Stem 17-4PH AISI 410 17-4PH 17-4PH 17-4PH 17-4PH
ENP ENP ENP ENP ENP
H1150 H1150 H1150 H1150 H1150

AST M 1 0 1 8 / AST M 1 0 1 8 /
AISI 1018/ AISI 1018/ AISI 316/ AISI 1018/ AISI 1018/ AISI 410/ AISI 1018/ AISI 316/ AISI 1018/
T3 Seat Assembly H F-40% H F/40%
E N P/TFE E N P/TFE H F/TFE E N P/TFE E N P/TFE N ITRO H E N P/TFE H F/TFE E N P/TFE
G FTFE G FTFE

AST M A 3 6 / AST M A 3 6 /
T4 Gate Skirt AST M A 3 6 AST M A 3 6 AISI 316SS AST M A 3 6 AST M A 3 6 AISI 410 AST M A 3 6 AST M A 3 6 AST M A 3 6
ENP ENP

AST M A 3 6 / AST M A 3 6 /
T5 Segment Skirt AST M A 3 6 AST M A 3 6 AISI 316SS AST M A 3 6 AST M A 3 6 AISI 410 AST M A 3 6 AST M A 3 6 AST M A 3 6
ENP ENP

Body/ Bonnet AST M A 1 9 3 AST M A 3 2 0 AST M A 1 9 3 AST M A 1 9 3 AST M A 3 2 0 AST M A 1 9 3 AST M A 1 9 3 AST M A 1 9 3 AST M A 1 9 3 AST M A 1 9 3 AST M A 1 9 3
A1
Studs B7 L7 B 7 F L R CT D B7M L7M B7 B7M B7M B7M B7M B7M

Body/ Bonnet AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4
A2
Nuts 2H G R. 7 2 H F L R CT D 2H M G R. 7M 2H 2H M 2H M 2H M 2H M 2H M

Yo k e Tu b e / AST M A 1 9 3 AST M A 3 2 0 AST M A 1 9 3 AST M A 1 9 3 AST M A 3 2 0 AST M A 1 9 3 AST M A 1 9 3 AST M A 1 9 3 AST M A 1 9 3 AST M A 1 9 3 AST M A 1 9 3
A3
Bonnet Studs B7 L7 B 7 F L R CT D B7M L7M B7 B7M B7M B7M B7M B7M

Yo k e Tu b e / AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4 AST M A 1 9 4
A4
Bonnet Nuts 2H G R. 7 2 H F L R CT D 2H M G R. 7M 2H 2H M 2H M 2H M 2H M 2H M

F1 P a ck i n g F i t t i n g Steel 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST

P a ck i n g P l u g /
F2 Steel 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST
Ve n t

B o d y Ve n t / G r s
F3 Steel 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST 1 8 - 8 S ST
Fitting

RV - Ry to n / V i to n
LR - L a n t e r n R i n g / Ry to n / V i to n
GT - G e ot h e r m a l / EPR
GV - G r a p h o i l / V i to n

10
Operator Sizing Requirements 2 - 4 C l a ss e s 6 0 0 - 9 0 0
6 - 3 6 C l a ss e s 3 0 0 - 9 0 0

S TE M T H READ
RECO M M ENDED RECO M M ENDED M AXI M U M M AXI M U M TOTAL
AN S I WORKIN G
SIZE OPERATIN G OPERATIN G ALLOWABLE ALLOWABLE S TE M TURN S
PRE S S URE SIZE PITC H LEAD
CLA S S T H RU S T TOR Q UE T H RU S T TOR Q UE TRAV EL TO
OPEN
in/MM p s i / Ba r Kg / c m 2 in/MM in/MM in/MM L b / KG F t- L b N-M L b / KG F t- L b N-M in/MM

1,500 2,526
600 105 17 23
2 (103.4) .88 0.167 0.167 (1,146) 16,289 2.75
108 146 16.5
(50) 2,250 (22.2) (4.2) (4.2) 3,788 (7,388) (69.85)
900 158 25 34
(155.1) (1,718)
1,500 6,612
600 105 63 86
4 (103.4) 1.250 0.250 0.250 (2,999) 31,868 4.88
305 413 19.5
(100) 2,250 (31.7) (6.3) (6.3) 9,918 (14,453) (124)
900 158 95 129
(155.1) (4,498)
750 6,400
300 53 73 99
(51.7) (2,902)
6 1,500 1.500 0.286 0.286 12,800 48,000 7.06
600 105 146 197 546 740 25
(150) (103.4) (38.1) (7.2) (7.2) (5,805) (21,769) (179.3)
2,250 19,199
900 158 218 296
(155.1) (8,707)
750 10,994
300 53 161 219
(51.7) (4,986)
8 1,500 2.000 0.333 0.333 21,987 94,177 9.25
600 105 322 437 1,380 1,872 28
(200) (103.4) (50.8) (8.4) (8.4) (9,972) (42,711) (235)
2,250 32,981
900 158 483 656
(155.1) (14,957)
750 16,126
300 53 259 351
(51.7) (7,313)
10 1,500 2.250 0.333 0.333 32,251 127,226 11.38
600 105 517 702 2,041 2,767 34
(250) (103.4) (57.1) (8.4) (8.4) (14,626) (57,699) (289)
2,250 48,377
900 158 776 1,052
(155.1) (21,940)
750 21,574
300 53 346 469
(51.7) (9,784)
12 1,500 2.250 0.333 0.333 43,152 127,226 13.31
600 105 692 939 2,041 2,767 40
(300) (103.4) (57.1) (8.4) (8.4) (19,570) (57,699) (338)
64,723
900 2,250 158 1,038 1,408
(29,353)
750 32,444
300 53 566 767
(51.7) (14,714)
16 1,500 2.500 0.333 0.333 64,887 168,876 16.63
600 105 1,131 1,534 2,944 3,992 50
(400) (103.4) (63.5) (8.4) (8.4) (29,427) (76,588) (422.4)
2,250 97,331
900 158 1,697 2,301
(155.1) (44,141)
750 50,698
300 53 1,027 1,392
(51.7) (22,992)
20 1,500 2.875 0.400 0.400 101,396 220,220 22.00
600 105 2,053 2,784 4,460 6,047 55
(500) (103.4) (73) (10.1) (10.1) (45,984) (99,873) (559)
2,250 152,094
900 158 3,080 4,177
(155.1) (68,977)
22 1,500 2.875 0.400 0.800 142,124 199,542 24.25
600 105 3,866 5,243 5,429 7,361 30.3
(550) (103.4) (73) (10.1) (20.3) (64,455) (90,495) (616)
750 30,369
300 53 690 935
24 (51.7) 2.63 0.333 0.666 (13,775) 175,865 28.13
3,994 5,415 42
(600) 1,500 (66.8) (8.4) (16.9) 151,845 (79,771) (715)
600 105 3,449 4,676
(103.4) (68,876)
750 112,888
300 53 3,063 4,153
(51.7) 3.13 0.400 0.800 (51,205) 250,000 32.88
6,800 9,220 41
30 1,500 (79.5) (10.1) (20.3) 225,775 (113,400) (835)
600 105 6,126 8,306
(750) (103.4) (102,410)
2,250 4.13 0.500 1.00 405,230 857,135 33.00
900 158 15,173 20,572 32,070 43,481 33
(155.1) (104.9) (12.7) (25.4) (183,809) (388,790) (838)
36 1,500 4.38 0.500 1.00 368,129 550,645 38.75
600 105 14,349 19,455 21,463 29,100 38.8
(900) (103.4) (111.3) (12.7) (25.4) (166,980) (249,768) (984.3)

Notes:
1. Recommended operating thrust and torque values are the loads required to open and close the valve. These torques do not contain service or safety factors.
2. Recommended operating torque and thrust values are based on maximum working pressure at ambient temperature. To obtain expected torques at lower temperatures, contact
M&J Valve.
3. Actuator selection should be made based on experience and appropriate service/safety factors.
4. Maximum allowable thrust and torque values are the maximum allowable loads of the valve.
* For sizes/classes not listed, contact M&J Valve for details.

11
2- 36 Rising Stem Expanding Gate Valves
P r i n c i pa l D i m e n s i o n s

H a n d wh e e l
O p e r at e d
B eve l G ear
( H WO )
O p e r at e d
Mod e l EG
(BGO)
Mod e l EG

CLAS S 300
SIZE
IN ( M M )
A A B C D D E E F WEI G HT
( R J) (RF ) (HWO) (B G O) (HWO) (B G O) (B G O) LB S (KG S )

6 16.50 15.88 6 12.63 50.25 51.25 18 18 29.50 550


(150) (419) (403) (152) (321) (1,276) (1,302) (457) (457) (749) (249)

8 17.13 16.50 8 15.50 61 62 26 24 35.63 850


(200) (435) (419) (203) (394) (1,550) (1,575) (660) (610) (905) (385)

10 18.63 18 10 20 73.25 74.25 32 24 43.38 1,250


(250) (473) (457) (254) (508) (1,860) (1,886) (813) (610) (1,102) (567)

12 30.13* 30* 12 23 82.13 85.88 32 28 49.25 1,900


(300) (765) (762) (305) (584) (2,086) (2,181) (813) (711) (1,251) (862)

12.375 30.13* 30* 12.38 23 82.13 85.13 32 28 49.25 1,900


(314) (765) (762) (314) (584) (2,086) (2,162) (813) (711) (1,251) (862)

12.5 30.13* 30* 12.50 23 82.13 85.13 32 28 49.25 1,900


(317) (765) (762) (318) (584) (2,086) (2,162) (813) (711) (1,251) (862)

16 33.63 33 15.25 28.75 101.25 30 58.50 3,500


- -
(400) (854) (838) (387) (730) (2,572) (762) (1,486) (1,587)

20 41.75* 41.5* 19.25 38.5 123.75 36 75 6,500


- -
(500) (1,060) (1,054) (489) (978) (3,143) (914) (1,905) (2,948)

24 45.88 45 23.25 51.5 144 36 88 11,500


- -
(600) (1,165) (1,143) (591) (1,308) (3,658) (914) (2,235) (5,215)

30 66 60 29 60 172 36 102 18,500


- -
(760) (1,676) (1,651) (737) (1,524) (4,369) (914) (2,591) (8,391)

I n ch
(millimeter)

* 4 0 0 E n d - To - E n d
F l a n g e d i m e n s i o n s c o n f o r m to Am e r i ca n N at i o n a l S ta n da r d I n s t i t u t e S ta n da r d B 1 6 . 5 .
Ot h e r s i z e s a n d p r e ss u r e s ava i l a b l e o n r e q u e s t.
I n f o r m at i o n o n p ow e r - act uat e d a n d ot h e r t y p e s ava i l a b l e o n a p p l i cat i o n .

12
CLA S S 6 0 0
SIZE
IN / M M A A B C D D E E F W EI G H T
IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M LB / KG

DN (RJ) (R F) ( H WO ) (B G O) ( H WO ) (B G O) (B G O) (LB S.) ( KG S . )

2 11.63 11.5 2.06 5.38 17.75 12 95


- - -
(50) (295) (292) (52) (137) (451) (305) (43)

4 17.13 17 4.06 8.88 31.25 16 350


- - -
(100) (435) (432) (103) (226) (794) (406) (159)

6 22.13 22 6 12.63 43 44 18 18 29.5 695


(150) (562) (559) (152) (226) (1,092) (1,118) (457) (457) (749) (315)

8 26.13 26 8 15.5 55 56 26 24 35.63 1,025


(200) (664) (660) (203) (394) (1,397) (1,422) (660) (610) (905) (465)

10 31.13 31 10 19.75 65 66 32 24 43.38 1,750


(250) (791) (787) (254) (502) (1,651) (1,676) (813) (610) (1,102) (794)
33
12 33.13 12 23 66.25 70 32 28 49.25 2,600
(838)
(300) (942) (305) (584) (1,683) (1,778) (813) (711) (1,251) (1,179)

12.975 33.13 33 12.38 23 66.25 70 32 28 49.25 2,600


(315) (842) (838) (314) (584) (1,683) (1,778) (813) (711) (1,251) (1,179)

12.50 33.13 33 12.5 23 66.25 70 32 28 49.25 2,600


(320) (842) (838) (318) (584) (1,683) (1,778) (813) (711) (1,251) (1,179)

16 39.13 39 15.25 28.75 81 30 61.25 4,450


- -
(400) (994) (991) (387) (730) (2,057) (762) (1,556) (2,018)

20 47.25 47 19.25 38.5 107 36 75 7,400


- -
(500) (1,200) (1,194) (489) (978) (2,718) (914) (1,905) (3,356)

22 51.38 51 21.25 42.25 140 36 83.8 11,000


- -
(550) (1,305) (1,295) (540) (1,073) (3,556) (914) (2,129) (4,989)

24 55.38 55 23.25 51.5 144 36 88 12,000


- -
(600) (1,407) (1,397) (591) (1,308) (3,658) (914) (2,235) (5,442)

30 65.50 65 29 60 172 36 102 24,200


- -
(600) (1,664) (1,651) (737) (1,524) (4,369) (914) (2,591) (10,997)

36 82.50 82 35 68 35,000
* * * * *
(900) (2,096) (2,083) (889) (1,727) (15,905)

* Contact M&J Valve for details.

CLA S S 9 0 0
SIZE
IN / M M
A A B C D D E E F W EI G H T
IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M IN / / M M LB S / KG

DN (RJ) (R F) ( H WO ) (B G O) ( H WO ) (B G O) (B G O) (LB S.) ( KG S . )

2 14.63 14.5 2.06 5.38 17.75 12 145


- - -
(50) (372) (368) (52) (137) (451) (305) (66)

4 18.13 18 4.06 9 31.25 16 510


- - -
(100) (461) (457) (103) (229) (794) (406) (231)

6 24.13 24 6 12.81 45 46 18 18 29.5 860


(150) (613) (610) (152) (325) (1,143) (1,168) (457) (457) (749) (390)

8 29.13 29 8 15.75 55 56 26 24 35.63 1,270


(200) (740) (737) (203) (400) (1,397) (1,422) (660) (610) (905) (576)

10 33.13 33 10 20 65 66 32 24 43.63 2300


(250) (842) (838) (254) (508) (1,651) (1,676) (813) (610) (1,108) (1,043)

12 38.13 38 12 23.5 66.25 66 32 30 49.25 3,500


(300) (969) (965) (305) (597) (1,683) (1,676) (813) (762) (1,251) (1,587)

12.374 38.13 38 12.38 23.5 66.25 70 32 30 49.25 3,500


(315) (969) (965) (314) (597) (1,683) (1,778) (813) (762) (1,251) (1,587)

12.5 38.13 38 12.5 23.5 66.25 70 32 30 49.25 3,500


(320) (969) (965) (318) (597) (1,683) (1,778) (813) (762) (1,251) (1,587)

16 44.88 44.5 14.75 30.25 81 30 66.5 7,300


- -
(400) (1,140) (1,130) (375) (768) (2,057) (762) (1,689) (3,311)

20 52.5 52 18.63 51.5 107 36 75 9,200


- -
(500) (1,334) (1,321) (473) (1,118) (2,718) (914) (1,905) (4,172)

30 85.50 85 28.50 57.75 37,000


- - - - -
(750) (2,172) (2,159) (724) (1,467) (16,783)

13
Yoke Tube Flange Dimensions

( 2 Th r o u gh 1 6 o n ly )

A B C D E F G H J K L
SIZE
IN CLA S S
(M M)
IN / M M IN / M M IN / M m IN / M m IN / M m IN / M m IN / M m IN / M m IN / M m IN / M M IN / M m

2.313
4 9.63 4.76 20.13 1.50 (58.8) .19 5.00 0.63 4.00 ( 4 ) . 4 4 DIA . S TRADDLE CL 10
300-900
(100) (244.6) (120.9) (511.3) (38.1) 2.318 (4.8) (127) (16.0) (101.6) (11.1) (254)
(58.9)
3.765 *5.50 ( 4 ) . 6 9 DIA . S TRADDLE CL
6 11.31 4.25 26.31 2.56 (95.6) .19 8.50 1.25 (139.7) (17.5) 11
300-900
(150) (287.2) (107.9) (668.2) (65) 3.775 (4.8) (215.9) (31.7) *6.50 ( 4 ) . 8 1 DIA . ON CL (279.4)
(95.8) (165.1) (20.5)
3.765 *5.50 ( 4 ) . 6 9 DIA . S TRADDLE CL
8 15.13 5.88 32.13 3.38 (95.6) .19 8.50 1.25 (139.7) (17.5) 15
300-900
(200) (384.3) (149.3) (816.1) (85.8) 3.775 (4.8) (215.9) (31.7) *6.50 ( 4 ) . 8 1 DIA . ON CL (381)
(95.8) (165.1) (20.5)
3.765 *5.50 ( 4 ) . 6 9 DIA . S TRADDLE CL
10 17.56 6.19 39.75 3.38 (95.6) .19 8.50 1.25 (139.7) (17.5) 17.50
300-900
(250) (446) (157.2) (1,009.6) (85.8) 3.775 (4.8) (215.9) (31.7) *6.50 ( 4 ) . 8 1 DIA . ON CL (444.5)
(95.8) (165.1) (20.5)
5.015
(127.3) ( 4 ) . 8 1 DIA . S TRADDLE 19.50
12 19.50 6.19 44.75 3.38 .25 8.50 1.25 6.50
300-900 CL (495.3)
(300) (495.3) (157.2) (1,136.6) (85.8) 5.025 (6.3) (215.9) (31.7) (165.1)
(20.5)
(127.6)
5.015
(127.3) ( 4 ) . 8 1 DIA . S TRADDLE
16 22.75 6.13 56.75 3.50 .25 8.31 1.50 6.50 24
300-900 CL
(400) (577.8) (155.7) (1,441.4) (88.9) 5.025 (6.3) (211) (38.1) (165.1) (609.6)
(20.5)
(127.6)
7.005
20 30.63 8.63 65.50 6.06 (177.9) .31 13.50 2.63 11.75 ( 8 ) . 8 8 DIA . S TRADDLE CL 31.25
300-900
(500) (778) (219.2) (1,663.7) (153.9) 7.010 (7.8) (342.9) (66.8) (298.4) (22.3) (793.7)
(178)
7.005
22 34.67 10.00 76.26 6.06 (177.9) .31 13.50 2.63 11.75 ( 8 ) . 8 8 DIA . S TRADDLE CL 34.93
300-900
(550) (880.6) (254.0) (1,937.0) (153.9) 7.010 (7.8) (342.9) (66.8) (298.4) (22.3) (887.2)
(178)
7.005
24 38.06 9.94 81.00 5.04 (177.9) .31 13.50 1.63 11.75 ( 8 ) . 8 8 DIA . S TRADDLE CL 37.5
300-600
(600) (966.7) (252.4) (2,057.4) (128) 7.010 (7.8) (342.9) (41.4) (298.4) (22.3) (952.5)
(178)
8.505
(216) ( 8 ) 1 . 3 8 DIA S TRADDLE
30 43.38 10.50 93.13 6.06 .31 16.75 2.63 14.0 43.5
300-600 CL
(750) (1,101.8) (266.7) (2,365.5) (153.9) 8.510 (7.8) (425.4) (66.8) (355.6) (1,104.9)
(35)
(216.1)
9.005
(228.7) ( 8 ) 1 . 3 8 DIA S TRADDLE
36 48.62 11.92 115.13 7.98 .75 18.75 2.63 16.0 48.75
300-600 CL
(900) (1,234.9) (302.8) (2,924.3) (202.7) 9.010 (19.1) (476.3) (66.8) (406.4) (1,238.3)
(35)
(228.9)

* Contact M&J Valve for details.

14
Notes:

15
Expanding
Gate Valve

ABOUT S PX

Based in Charlotte, North Carolina, SPX Corporation (NYSE: SPW) is a global multi-industry manufacturing leader. For more information, please visit www.spx.com.

S PX F low T e c h n o lo gy

8800 Westplain Drive


Houston, TX 77041
P: (800) 231-3690 or (281)469-0550
F: (281) 894-1332
E: mjvalve@spx.com

SPX reserves the right to incorporate our latest design and material changes without notice or obligation.
Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only and should not be relied
upon unless confirmed in writing. Please contact your local sales representative for product availability in your region. For more information visit www.spx.com.
The green > is a trademark of SPX Corporation, Inc.
ISSUED 07/2014 MJ-1645-US COPYRIGHT 2014 SPX Corporation

Das könnte Ihnen auch gefallen