JHF-Model Precision Filter

Hangzhou Jialong Air Equipment Co. Ltd.

0
Product Briefing
For the compressed air filters, all the filtration cores refer to the
original-state products by the world-famous US HANKISON Company and the
shells of the filters are designed according to the prototype of HANKISON
Company, including five grades of Grade 9, Grade 7, Grade 5, Grade 3 and
Grade 1, etc. by different degrees of filtration precision.
The compressed air runs into the filter and removes effectively the
contaminants such as moisture, dust and oil fume, etc. in the compressed
air, thus the compressed air is made clean and dry to improve the
reliability of the pneumatic equipment and the quality of the product. As
the filtration cores of HANKISON Company are constructed with multi-layer
filter bed, their extremely high dust containing capacity, high
effectiveness and long lifespan have been unanimously recognized in the
world compressed air purification equipment domain. The filters made by our
company are simple in structure, easy for filter cores to be mounted and
dismantled and secured in operation performance. We provide the following 5
grades of filters for your selection:
Installation and deployment
1. For the convenience of operation and replacement for maintenance, the
filter should be installed according to the pipeline indicated in the chart

on the right:
2. The deployment of the filter can refer to the pattern indicated in the
following chart

1
Model and maintenance
1 The filters made by our company are the equipment that takes the
compressed air as the medium. It is strictly forbidden to run other media
directly into the filter. Pay special care not to exceed the specified
maximum work. Take special care not to exceed the specified maximum work
condition at use.
2The filtration precision of the compressed air filter is determined under
certain condition. The inlet air quality has obvious influence over the
operation effect of the precision filter cores. When necessary the proper
prep0sitive filter should be added to make the pretreatment of the inlet
air quality. The filter deployment and installation should follow the JHF9
JHF7 JHF5 JHF3 JHF1 sequence. Otherwise the filtration effect
will not be reached and the lifespan of the filter cores will be reduced by
big margin.
3The filter core is the principal part of the filter. The pressure drop at
the filter inlet and outlet should be checked regularly at work. When
pressure drop reaches higher than 0.07MPa, then the work lifespan of the
filter core is nearly at the end and the filter or the filter core must be
replaced in time (The initial pressure drop of a single filter core is
about (0.01-0.02)MPa.
4Should be resistant to chemical causticity. Generally the compressed air
does not contain any contaminants harmful to filter cores. However, some
hydrocarbon species, acid species, alkali species and some special chemical
substances may enter into the filter through compressor under the special
circumstances.
5Filter must raise or reduce pressure slowly at operation and dismantling
of the filter should be performed under the pressure-free condition.
6 Replacement of filter cores: Should take care during dismantling or
mounting the filter core. Should not hold the filter core barrel with hand
to avoid the surface filter material of the filter core from being damaged.
7 For the filters equipped with manual sewerage, should not open the
sewerage under the pressure situation (The filter mounted with automatic
sewerage will automatically discharge the accumulated water in the filter

2
barrel).
8Should not select filter by the diameter of the fitting pipe, while the
air treatment capacity and the usage pressure should be taken for selecting
a filter.
9By strictly following the above conditions, the use lifespan of the HF9,
HF7, HF5, and Hf3 types of filter cores in this series can reach over 8000
hours and that of HF1 type of filter cores will be 2500 hours (It is taken
to be the work lifespan limit when the work pressure drop of a single
filter core reaches 0.07MPa).

The operating pressure is 7.0MPa, belong to special


operating pressure.
Alarm:
1
Please dont change the drain time that was setted.
2 Please attention drain direction when install organ of
catch water, for fear the high-pressure air to harm people
if draining.

3
HANGZHOU

JIALONG

HANGZHOU JIALONG AIR EQUIPMENT CO.LTD
Address; #198 Shenjia Road, Shiqiao, Hangzhou
Tel: 0571-85365111
Fax: 0571-85365000
Post code: 310004
E-mailhzjr@21cn.com
Httpwww.Jialongequip.com.cn