STEP-1,

Install the device safely inside the vehicle in the recommended location
GUIDE TO USE IN A AUTOMOBILE VEHICLE 1. Make sure all the windows are closed (leaving a small gap on the glass window for the
power cable & gently close it with a cloth to stop air leakage)
Do not stay inside the ODOUR removal results may vary based on the actual condition of 2. Open the Dashboard inside the car.
vehicle while running the the vehicle & its interior materials used. Example: Use of decorative INLET
PorTABLE UV device. materials, Type of goods stored, indoor cleanness, etc. STEP-2, Switch ON the Car/Van/Bus
1. Switch ON the Vehicle AC & keep the fan speed level between 2 to 4 for
Always read the safety instruction manual for the safe use of UV Equipment. air circulation.
2. Open the fresh air intake valve.
3. Switch ON the STERi Portable Device.
STEP-3, Waiting Time-1; Wait for 5 min (Small size vehicles); Wait for 10 min (Big, long vehicles)
For small size car place
the PorTABLE device on 1. Close the fresh air intake valve & let the UV unit, car engine & AC keep running.
the rear seat (1 nos
STEP-4, Waiting Time-2; Wait for recommended duration w.r.t to vehicle size & type.
INLET device is required)
(30min, 45min, 60min, 90min, 120min) Longer the waiting time higher the UV treatment effect.
Duration:
STEP-5, Switch OFF the UV device; Switch off the Vehicle & AC.
30 min to 60min
1. Remove the UV device safely from the vehicle.
2. Wait for 15min with all doors closed (optional & it will extend the treatment time).
3. Your vehicle is now ready to use. (If you want to immediately use the vehicle, opening all the doors &
When the rear cabin is window glass for 2~4min)
divided from the driver 4. If you want to extend the UV treatment then you can extend the Waiting time in STEP-4 & continue the
seat, then use two UV process again.
INLET
devices to save time. Note:
Example: Ambulance, 1. For better result remove all the unwanted items kept inside the vehicle.
Food truck, etc.
2. Clean your vehicle with regular method (vacuum m/c) to remove visible dust particles, waste, food items,
drinks, etc. before running the STERi equipment.
3. Do not use STERi equipment immediately after painting the interior. Wait at least for 1-week time (or as
Duration:
per painting specification) for the paint to dry completely to have better result.
60 min to 120 min
4. Devices will not remove dust particles, insects inside the vehicle.
(Longer the food trucks
INLET
treatment better the 5. Do not run the UV device when the vehicle indoor surfaces, floor and seats are wet.
results) 6. Do not rough handle the UV device; it may damage the UV unit. Always handle the device gently.
7. Once 9000 hour is completed. Please call our customer support team for service & replacement.

For Big size Car, single


PorTABLE device located
at the middle of the INLET INLET
INLET vehicle will be sufficient

Duration:

45 min to 90 min For long vehicles like bus & van we highly recommend to use 2nos
Visit www.limat.xyz
PorTABLE UV devices simultaneously on two ends. Duration: 90 min to 120 min


Visit www.limat.xyz GUIDE TO USE IN A SMALL & BIG SIZE ROOMS

Do not stay inside the


indoor space while
running the PorTABLE
UV device.

Wall Mounting Unit can be


mount permanently inside UV Device is highly recommended in places where Split
your indoor for continuous ACs are used for room air conditioning. Also in places
indoor treatment (or)
PorTABLE Unit can be WALL MOUNTED UV DEVICE
used as & when required.
STEP-1, Install the device in your indoor place safely & connect the power cable to the power source.
1. If you are in the AC room, then install the device just below the air intake of the AC unit.
2. If you in the NON/AC room install the device a feet away from the fan or at the best air circulation
PORTABLE UV DEVICE location.
3. Keep 1.5meter height from the floor lever while mounting the device in the wall.
STEP-1, Install the device safely inside the room in a place where room air circulation is 4. Maximum air circulation should be available in the place where the device is installed.
high
STEP-2, Power ON the device
1. If you are in the AC room install the device just below the air intake. Time Schedule for a Work Places
1. When the device start running you can see the RED indicator glows.
2. If you in the NON/AC room install the device a feet away from the room ceiling fan or
STEP-3, Power OFF the device (use timer for auto ON/OFF) 1. 3omin before & after office open time.
at the best air circulation location.
2. 3omin during break time.
STEP-4, Open the doors & windows if you find any dis-comfort while
STEP-2, Close all the Opening in the room, to make sure no (or) min leakage of air during 3. 6omin during the lunch time
Note: (For Wall Mounting UV ComPACT Device) 4. 3omin during break time.
the entire process for best result
1. Read the instruction manual before running the Device. 5. 1hr after office close time.
1. Close all the windows, & make sure no visible openings are found. 2. Wall mounting device are recommended to use in places where continuous dis-infection,
2. Close all the doors & door gap if any on the bottom. sterilization & cleaning is required.
3. Wall mounting device are highly recommended to use in place where opening & closing of door & windows are very frequent. (Best example are a Doctors
consultation room, Beauty Parlor, Internet Cafe, Gym, etc.)
STEP-3, 4. It is normal that, some time you might feel a burnt smell while the device is running inside the room. Simply open the doors for a while or stop the device.
5. Do not run the device without mounting it in the wall. (Read the safety precaution on the device instruction manual)
1. SWITCH ON THE AC & keep the swing position facing straight direction. 6. If you are using in a public toilet, office toilets we recommend to use timer to control the device at pre-defined interval.
2. SWITCH ON the STERi Portable Device & make sure everything is ok. 7. Automatic ON/OFF can be done using a timer device by pre-programming it for the whole week based on the office working hours.
3. Leave the room and let the device run.
THINGS TO REMEMBER IN GENERAL
STEP-4, Wait for the recommend time based on the room size & interior for maximum KEEP THE SHELVES, CUP-BOARS OPEN DURING THE
Note: (For UV PorTABLE Device)
cleaning result STERILIZATION PROCESS, SO THAT TREATED AIR WILL
1. For better result remove all the unwanted items stored, left FLOW EACH AND EVERY CORNER OF THE ROOM FOR
1. Power OFF the device & remove it from the room. inside the room.
2. indoor with regular method (mop, vacuum m/c) to
Clean your MAXIMUM EFFECT.
2. Keep all the doors closed wait for another 15~20 min (not DEVICE RUNNING
mandatory) DURATION remove visible dust particles, waste, food items, drinks, etc. IN YOU ARE PLANNING TO WASH YOUR INTERIOR THINGS
before running the STERi equipment.
LIKE CURTAINS CLOTHS, SCREENS, SOFA COVERS, AND
For every 3. Do not use STERi equipment immediately after painting the
STEP-5, Open the doors & few window for 3~5min keeping the AC / interior. Wait at least for 1-week time (as per painting spec.) for DECORATIVE SHOW CASE MATERIALS THEN DO IT BEFORE
150~250sqft of indoor
FAN running. space, use one
the paint to dry completely to have better result. THE STERILZATION PROCESS.
4. Devices will not remove dust particles, insects inside the vehicle.
PorTABLE UV Device 5. Do not run the unit when vehicle indoors surfaces, floor are wet
DO NOT USE THE DEVICE WIHTOUT PROPER KNOWLEDGE &
1. Now your indoor is ready for use. for one hour. GUIDANCE FOR THE SAFETY OF THE OPERATOR.
(Results may vary)