Sie sind auf Seite 1von 2

OTDR report

Job info
Job ID : Reason :
Contractor : Operator A :
Customer : Operator B :
Test date : 8/9/2017 (12:44:29 PM GMT+1:00) File : C21.trc

Cable info
Fiber ID : Fiber22 Cable ID :
Location A : Location B :
Cable mfr. : Type :
Subset ID : Color ID :

Link measurements
Span loss : 4.955 dB Avg. splice loss : 3.399 dB
Span length : 5.2772 km Max. splice loss : 3.399 dB
Average loss : 0.939 dB/km Span ORL : 0.00 dB

OTDR trace

dB

40.00
1

35.00

30.00

25.00

3
20.00

2
15.00

10.00

5.00

0.00
1 2 3 4 5 6 7 8 9 km

Signature : _________________________ Date : 8/10/2017


Corning Page 1 / 2
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level --- >-26.2 0.000


Fiber Section (2.9318 km) 1.071 0.365 1.071
2 2.9318 Non-Reflective Fault 3.399 4.470
Fiber Section (2.3454 km) 0.484 0.207 4.955
3 5.2772 Reflective Fault --- -14.2 4.955

Marker info
A : N/A B : N/A
a : N/A b : N/A
A to B distance : N/A A to B ORL : N/A
3-pt. reflectance : N/A A to B LSA att. : N/A
4-pt. Ev. loss : N/A

Test and cable setup


Wavelength : 1550 nm (SM-9m) Acq. time : 5s
Filename : C21.trc Pulse width : 100 ns
Hardware : MAX-730B-M3-EA Helix factor : 0.00 %
Serial number : 903132 Splice loss threshold : 0.020 dB
Software : N/A Reflectance threshold : -72.0 dB
Range : 10.0000 km End-of-fiber threshold : 5.000 dB
IOR : 1.468325
RBS : -81.87

Signature : _________________________ Date : 8/10/2017


Corning Page 2 / 2